7

Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall

Embed Size (px)

Citation preview

Page 1: Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall
Page 2: Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall
Page 3: Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall
Page 4: Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall

SCALE: 1/4" = 1'-0"

WASTE & VENT PIPING PLAN

FS

TIE INTO

NEAREST VENT

V

1-1/2"

TIE INTO

NEAREST VENT

V

1-1/2"

TIE INTO

NEAREST VENT

V

1-1/2"

FD

TD

FS

FS

FS

1

KEY NOTES

INDICATED BY SYMBOLS , , ETC.

1. REUSE EXISTING DRAIN AND VENT LINES

SERVING EXISTING HAND SINK FOR NEW

HAND SINK.

2. EXISTING FLOOR DRAIN/FLOOR SINK TO

REMAIN.

3. EXISTING FLOOR DRAIN/FLOOR SINK TO BE

REMOVED. CAP WASTE LINE BELOW SLAB

AND REPAIR SLAB PER ARCHITECT'S

DIRECTION.

4. EXISTING FLOOR CLEANOUT TO REMAIN.

5. EXISTING FLOOR CLEANOUT TO BE

REMOVED. EXTEND WASTE LINE TO NEW

CLEANOUT LOCATION. REPAIR SLAB PER

ARCHITECT'S DIRECTION.

6. EXISTING 4" GREASE WASTE LINE.

7. EXISTING 4" SANITARY WASTE LINE.

GENERAL NOTES

1. ALL PLUMBING WORK SHALL COMPLY WITH

THE 2009 EDITION OF THE INTERNATIONAL

PLUMBING CODE.

2. DRAWING IS DIAGRAMMATIC AND IS NOT TO

BE SCALED. REFER TO ARCHITECTURAL

PLANS AND FIELD CONDITIONS FOR

DIMENSIONS.

3. SEE SPECIFICATIONS FOR PIPING, VALVE

AND INSULATION REQUIREMENTS.

4. PLUMBING FIXTURES ARE TO BE

FURNISHED COMPLETE WITH ALL

NECESSARY STOPS, TRAPS, TAILPIECES,

TRIM, ETC.

5. PROVIDE WATER HAMMER ARRESTERS ON

THE SUPPLY PIPING (CW & HW) WHERE

INDICATED ON THE PLAN. ARRESTERS

SHALL BE SIOUX CHIEF MODEL 652-A OR

EQUAL. INSTALL ARRESTERS PER THE

MANUFACTURER'S RECOMMENDATIONS.

THE ARRESTERS SHALL BE RATED FOR

INSTALLATION IN CONCEALED LOCATIONS.

CAPPED AIR CHAMBERS ARE NOT

ALLOWED.

6. ALL HOT AND COLD WATER SUPPLY PIPING

CONNECTION TO FIXTURES ARE TO BE 1/2",

UNLESS NOTED OTHERWISE.

7. THE CONTRACTOR SHALL COORDINATE

WITH ALL OTHER CONTRACTORS AND

SUBCONTRACTORS IN LAYING OUT AND

INSTALLING HIS WORK. COORDINATION

DOES NOT MEAN "I WAS HERE FIRST".

8. THE CONTRACTOR IS RESPONSIBLE FOR

INSTALLING A COMPLETE AND OPERABLE

SYSTEM IN ACCORDANCE WITH THE INTENT

OF THE PLANS, WHETHER OR NOT EVERY

ELEMENT THEREOF IS SPECIFICALLY

CALLED OUT.

9. ALL FLOOR DRAINS, FLOOR SINKS AND

INTERIOR CLEANOUTS SHALL BE INSTALLED

FLUSH WITH FINISHED FLOOR COVERING.

FLOOR SHALL NOT BE SLOPED TO DRAIN

UNLESS SPECIFICALLY INDICATED ON THE

PLANS.

2

P08

P09

P10

P11

P11

P11

P14

P15

P16

1

S

KW

3

2

2

3

3

3

3

3

3

2

4

2

4

2

2

2

CO KW

6

6

7

S

KW

S

KW

S

KW

KW

KW

S

SS

KW

KW

S

KW

5

7

6

KW

TD

KW

V

1-1/2"

1

PROJECT:

Design. Spaces. People.

Fort Worth, Texas 76104

www.qarch.comfx. (817) 738-9524ph. (817) 738-8095

707 W. Vickery Blvd. #101

SOLICITATION ISSUE

04/15/16 95% SUBMITTAL

CDI

ARMY AND AIR FORCE EXCHANGE SERVICE

CONVERT :

TO BOSTON MARKET /

QDOBA

FT. CAMPBELL, KY

SCALE:

AFFES NO:

DATE:

2146-15-000007

AS NOTED

SHEET:

DRAWING TITLE:

DRAWING PROJ. NO.

16014

23 JULY 2016

05/23/16

SOLICITATION

ISSUE

CDI

06-23/16ADDENDUM #1

CDI

P-101

WASTE & VENT

PIPING PLAN

cduncan
Pen
as
cduncan
Pen
6-2314
Page 5: Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall

SCALE: 1/4" = 1'-0"

SUPPLY PIPING PLAN

RE-USE EXISTING

FW CONNECTION

1

KEY NOTES

INDICATED BY SYMBOLS , , ETC.

1. CONNECT TO EXISTING FILTERED WATER

LINE OF 1/2" OR LARGER AT EXISTING

WATER FILTER.

2. EXISTING 1" GAS LINE DOWN THROUGH

ROOF AT 7" W.C. CONNECT NEW 1" GAS LINE

BELOW ROOF PENETRATION.

3. CONNECT TO NEAREST GAS LINE ON ROOF

AT 5 PSI, 1" OR LARGER.

4. GAS PRESSURE REGULATOR ON ROOF. 5

PSI INLET PRESSURE TO 7" W.C. OUTLET

PRESSURE.

5. 1-1/4" GAS LINE DOWN THROUGH ROOF.

PROVIDE PITCH PAN AND PROPERLY SEAL

ROOF PENETRATION.

6. REUSE EXISTING 1/2" CW AND HW LINES

SERVING EXISTING HAND SINK FOR NEW

HAND SINK.

7. EXISTING 2" CW AND EXISTING 1" HW (140)

LINES.

8. THERMOSTATIC MIXING VALVE, LEONARD

MODEL 270-LF OR EQUIVALENT.

9. THIS SINK IS PROVIDED WITH TEMPERED

HW AND DOES NOT REQUIRE AN INDIVIDUAL

MIXING VALVE PER THE CONNECTION

SCHEDULE.

PLUMBING LEGEND

2

P04 P03

P01

P02

P05

P05

P05

P06

G01 G03 G02

P12

P13

G04

G06

G05

2

1"

3/4" 3/4"

G

G G

CW

FD

CO

R

COLD WATER

HOT WATER

BUILDING WASTE/SEWER

KITCHEN WASTE

VENT

GAS

EXISTING PIPE

PIPE BELOW GRADE

PIPING CONTINUATION

ELBOW UP

ELBOW DOWN

TEE

TEE UP

TEE DOWN

BALL VALVE

FLOOR DRAIN

CLEANOUT

GAS PRESSURE REGULATOR

HW

S

KW

V

G

WATER HAMMER ARRESTOR

FLOOR SINK

WALL CLEANOUT

WCO

ELBOW

FILTERED WATERFW

DENOTES "CONNECT TO

EXISTING"

R

CW

HW (140)

3

4

5

1"1-1/4" 1"

6

CW

HW (140)

CW

HW (140)

CW

HW

CW

HW

7

FW FW FW

FW

FW

FW

HW

CW

7

TEMPERING VALVE

1/2"

8

3/4"

3/4" 1"

3/4"

1"

1

9

3

R

3/4"

MAU-1

4

1

PROJECT:

Design. Spaces. People.

Fort Worth, Texas 76104

www.qarch.comfx. (817) 738-9524ph. (817) 738-8095

707 W. Vickery Blvd. #101

SOLICITATION ISSUE

04/15/16 95% SUBMITTAL

CDI

ARMY AND AIR FORCE EXCHANGE SERVICE

CONVERT :

TO BOSTON MARKET /

QDOBA

FT. CAMPBELL, KY

SCALE:

AFFES NO:

DATE:

2146-15-000007

AS NOTED

SHEET:

DRAWING TITLE:

DRAWING PROJ. NO.

16014

23 JULY 2016

05/23/16

SOLICITATION

ISSUE

CDI

06-23/16ADDENDUM #1

CDI

P-102

SUPPLY PIPING

PLAN

cduncan
Pen
test"
Page 6: Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall

3309

KITCHEN PLUMBING REQUIREMENT SCHEDULE

MARK ITEM SIZE LOCATION SERVICE TOA.F.F. REMARKS

P01

P02

P03

1. PIPE DRAIN INDIRECT TO FLOOR SINK/DRAIN. SEE KITCHEN EQUIPMENT PLANS FOR EQUIPMENT

LOCATIONS AND INDIRECT DRAIN SIZES.

2. REFERENCE DETAIL 1/P201.

3. TEE AT VALVE AND MAKE FINAL CONNECTION TO (2) DISPENSER.

4. INSTALL MANUAL VALVE AND AUTOMATIC VALVE (FIRE SUPPRESSION SYSTEM ACTUATED)BELOW CEILING.

INSTALL A GAS COCK FOR EACH APPLIANCE.

5. PROVIDE SHUT-OFF VALVE AND PROVIDE FINAL CONNECTION.

6. REFERENCE DETAIL 4/P201.

7. TEE AT WALL PENETRATION AT ROUGH IN TO TWO 3/4" CONNECTIONS.

8. PROVIDE POINT OF USE THERMOSTATIC MIXING VALVE LEONARD MODEL 170-LF OR EQUIVALENT.

9. PROVIDE POINT OF USE THERMOSTATIC MIXING VALVE LEONARD MODEL 270-LF OR EQUIVALENT.

REMARKS

P04

P05

P06

P07

P08

P09

P10

P11

G01

GENERAL NOTES

1. ALL EQUIPMENT IS AAFES FURNISHED/CONTRACTOR INSTALLED.

1/4"

WALL

HOT WATER DISPENSER

50"

-

4,7

-

G02

G03

5

5,8

5

5

3FILTERED WATER

11403/4"

WALL

ROTISSERIE OVEN, DOUBLE

18"

GAS

30403/4"

WALL

CONVECTION OVEN, DOUBLE

18"

GAS

38001/4"

WALL

RETHERMALIZER

24"

HW

45161/2"

WALL 1-COMP. SINK12"

CW/HW

45051/4"

WALL

VEGGIE WASH SYSTEM

48"

45501/2"

WALL

HAND SINK

18"

1/2"

WALL 12"

-

-

-

-

38003/4"

WALL

RETHERMALIZER

18"

GAS

CW

CW/HW

CW/HW

NOT USED

3"

FLOORFLOOR SINK --

4516

1-COMP. SINK1

1,6

1

2"

WALLDIRECT DRAIN 18"

3"

FLOORFLOOR SINK --

4623 POWERSOAK SINK

3800RETHERMALIZER

2"

WALLDIRECT DRAIN 16"

4550 HAND SINK

5,9

-

4,7

4

606

P12

1/4"

WALL

ICE MAKER

50"3

FILTERED WATER

P13

5

3171/2"

WALL PREP SINK FAUCET16"

CW/HW

P14

1

3"

FLOORFLOOR SINK --

113HOT FOOD TABLE

P15 3"

FLOORFLOOR SINK --

315

PREP SINK1

P16 3"

FLOORFLOOR SINK --

608

ICE BIN1

G04

4

G05

G06

1003/4"

WALL

FRYER

12"

GAS

1193/4"

WALL

OVEN / BROILER

12"

GAS

1213/4"

WALL

RANGE

12"

GAS

4

4

2x PIPE DIAMETER

CUT END OF WASTE LINE AT 45°

TO REDUCE SPLASHING.

CONCRETE SLAB

FLOOR COVERING

SET FLOOR SINK FLUSH

WITH FINISHED FLOOR

DOME STRAINER

NO HUB JOINT CLAMP

FLOOR SINK

P-TRAP

SET CLEANOUT FLUSH

WITH FINISHED FLOOR

FLOOR COVERING

CONCRETE SLAB

SAME SIZE AS WASTE

LINE

1/8 BEND ELBOWS

NO HUB JOINT CLAMP

P-TRAP

SET FLOOR DRAIN FLUSH

WITH FINISHED FLOOR

FLOOR COVERING

CONCRETE SLAB

NO HUB JOINT CLAMP

NOTE: DO NOT SLOPE FLOOR TO DRAIN

UNLESS OTHERWISE NOTED.

NOT TO SCALE

FLOOR SINK DETAIL 1

P201

NOT TO SCALE

INTERIOR CLEANOUT DETAIL 3

P201

NOT TO SCALE

FLOOR DRAIN DETAIL 2

P201

ATTACH RODS TO STRUCTURE

ABOVE USING BEAM CLAMPS OR

SIMILAR MEANS OF CONNECTION.

3/8" THREADED

ROD, TYPICAL

"UNISTRUT" P1000 1-5/8"

CHANNEL, LENGTH AS

REQUIRED.

1-PIECE PIPE CLAMP, TYPICAL PROVIDE

SHEET METAL SHIELD BELOW CLAMP

FOR INSULATED PIPE.

PIPE, TYPICAL

NOTE:

1. CLAMPS SHALL NOT INTERRUPT

INSULATION.

2. PROVIDE COPPER PLATED SUPPORTS

FOR UNINSULATED COPPER PIPING.

INSULATION, TYPICAL

PIPE SUPPORT SPACING

1/2" PIPING: 4'-0" CENTERS

3/4"-1" PIPING: 6'-0" CENTERS

1-1/4" AND LARGER PIPING: 10'-0" CENTERS

NOT TO SCALE

TRAPEZE PIPE HANGER DETAIL 5

P201

EQ

UA

L

L

C

EQ

UA

L

PIPE (TYPICAL GAS OR WATER LINE)

THREADED ROD

Z-PURLIN AT ROOF

PIPE HANGER SHALL BE ATTACHED TO

Z-PURLIN WITH BOLT, NUT AND WASHER

LOCATED AT CENTERLINE OF Z-PURLIN WEB

ONLY

B-LINE FIG. B3060 SIDE

BEAM ANGLE CLAMP

B-LINE FIG B3170 ADJUSTABLE

SWIVEL RING PIPE HANGER

PIPE SUPPORT SPACING

1/2" PIPING: 4'-0" CENTERS

3/4"-1" PIPING: 6'-0" CENTERS

1-1/4" AND LARGER PIPING: 10'-0" CENTERS

NOT TO SCALE

PIPE HANGER ATTACHMENT DETAIL 6

P201

CLEANOUT PLUG

IN TEE

2" DRAIN

TYPICAL

CLEANOUT

FLOOR SINK

2"

FINISHED

FLOOR

NOT TO SCALE

THREE COMPARTMENT SINK DETAIL 4

P201

CO CLEANOUT (INTERIOR) SEE PLANZN1400 ---- SAME SIZE AS LINE

PLUMBING FIXTURE SCHEDULE

PIPING REQUIREMENTS

VENT

MARK MODEL NO.DESCRIPTION MANUFACTURER ACCESSORIES

WASTE

REMARKS

SUPPLY

APPROVED MANUFACTURERS

FD ZURN 2" 1-1/2"FLOOR DRAIN ZN415BJAY R SMITH, WADE, MIFAB, JOSAM

-- --

5" NICKLE BRONZE LIGHT DUTY STRAINER

AND "PROSET" SYSTEMS TRAP GUARD

FS ZURN Z17513"

--1-1/2

DOME STRAINER, 8" SUMP DEPTH,

SEDIMENT BUCKET AND 1/2 GRATE

16 GA. 304 SS CONST, OUTLET

SIZE SAME AS LINE

1. COORDINATE THE ROUGH-IN OF ALL PLUMBING FIXTURES WITH THE ARCHITECTURAL PLANS.

2. PROVIDE SERVICE VALVES ON ALL SUPPLY FIXTURES.

NOTES:

FLOOR SINK

(12x12)

JAY R SMITH, WADE, MIFAB, JOSAM

ZURNJAY R SMITH, WADE, MIFAB, JOSAM

DURA-COATED CAST IRON BODY

W/POLISHED NICKEL BRONZE LIGHT

DUTY TOP

4623POWERSOAK SINK

TD TRENCH DRAIN Z-886-FSZURN

1

1

2" 1-1/2" --

HDPE TRENCH DRAIN WITH

SLOTTED STAINLESS STEEL

GRATE

--JAY R SMITH, MIFAB

1

PROJECT:

Design. Spaces. People.

Fort Worth, Texas 76104

www.qarch.comfx. (817) 738-9524ph. (817) 738-8095

707 W. Vickery Blvd. #101

SOLICITATION ISSUE

04/15/16 95% SUBMITTAL

CDI

ARMY AND AIR FORCE EXCHANGE SERVICE

CONVERT :

TO BOSTON MARKET /

QDOBA

FT. CAMPBELL, KY

SCALE:

AFFES NO:

DATE:

2146-15-000007

AS NOTED

SHEET:

DRAWING TITLE:

DRAWING PROJ. NO.

16014

23 JULY 2016

05/23/16

SOLICITATION

ISSUE

CDI

06-23/16ADDENDUM #1

CDI

P-201

PLUMBING SCHEDULES

& DETAILS

cduncan
Pen
A-tin."
Page 7: Campbell Boston Market... · waste & vent piping plan fs tie into nearest vent v ... pipe below grade piping continuation elbow up ... hand sink 1/2" wall 12" - - - - gas 3/4" wall

SCALE: 1/4" = 1'-0"

POWER PLAN

BOSTON MARKET

QDOBA

1

KEY NOTES

INDICATED BY SYMBOLS , , ETC.

1. RECEPTACLE AT SOFFIT FOR DIGITAL MENU

BOARD/PANEL. FIELD COORDINATE EXACT

ROUGH-IN LOCATION. COORDINATE

CONTROL WITH OWNER.

2. RECEPTACLE AT SOFFIT FOR DIGITAL

CONTROLLER. FIELD COORDINATE EXACT

ROUGH-IN LOCATION. COORDINATE

CONTROL WITH OWNER.

3. PROVIDE DATA OUTLET(S) AS REQUIRED

FOR DIGITAL MENU BOARD/PANEL(S) AND

DIGITAL CONTROLLER(S). COORDINATE

WITH EQUIPMENT PURVEYOR.

4. EXISTING KITCHEN HOOD RELOCATED,

REFER TO HVAC PLAN, SHEET M101.

EXTEND/RE-ROUTE EXISTING CIRCUITRY

AND CONTROL WIRING AS REQUIRED.

5. KITCHEN HOOD (KH-1) UTILITY CABINET.

REFER TO HVAC PLANS.

CIRCUITS: LBL-30/HOOD CONTROL AND

LIGHTS; LBL-32,34,36/EXHAUST FAN (EF-1);

LBL-38,40,42-MAKE-UP AIR (MAU-1).

6. #12'S TO KITCHEN HOOD UTILITY CABINET.

7. PROVIDE DUPLEX RECEPTACLE FOR

RELOCATED BAG-IN-BOX EQUIPMENT.

COORDINATE EXACT LOCATION AND

MOUNTING HEIGHT WITH EQUIPMENT.

EXTEND/RE-ROUTE EXISTING CIRCUITRY.

GENERAL NOTES

1. ALL ELECTRICAL WORK SHALL COMPLY

WITH THE 2011 EDITION OF THE N.E.C.

2. DRAWINGS ARE DIAGRAMMATIC AND ARE

NOT TO BE SCALED. REFER TO THE

ARCHITECTURAL PLANS AND FIELD

CONDITIONS FOR DIMENSIONS.

3. ALL CONDUCTORS SHALL BE COPPER.

4. ALL WIRING SHALL BE IN CONDUIT. CONDUIT

SHALL BE AS CALLED FOR ON PLANS OR

WHERE PLANS DO NOT INDICATE, CONDUIT

SHALL BE AS CALLED FOR IN

SPECIFICATIONS.

5. ALL WIRING IN FINISHED SPACES SHALL BE

CONCEALED, UNLESS NOTED OTHERWISE.

6. THE ELECTRICAL SYSTEM DESIGN IS BASED

IN PART ON THE HVAC EQUIPMENT

SPECIFIED ON THE MECHANICAL

DRAWINGS. IT IS THE RESPONSIBILITY OF

THE CONTRACTOR TO COORDINATE THE

ELECTRICAL REQUIREMENTS OF THE HVAC

EQUIPMENT BEING FURNISHED AND TO

PROVIDE THE CORRECT CONDUCTORS AND

BREAKERS WITH NO ADDITIONAL COST TO

THE OWNER. SHOULD THE LOAD OF THE

EQUIPMENT BEING FURNISHED RESULT IN

THE NEED TO INCREASE THE AMPACITY OF

THE PANELS OR FEEDERS, THAT WORK

SHALL ALSO BE PROVIDED AT NO

ADDITIONAL COST TO THE OWNER.

7. THE CONTRACTOR IS RESPONSIBLE FOR

INSTALLING A COMPLETE AND OPERABLE

SYSTEM IN ACCORDANCE WITH THE INTENT

OF THE PLANS WHETHER OR NOT EVERY

ELEMENT THEREOF IS SPECIFICALLY

CALLED OUT.

8. COORDINATE ALL WORK WITH OTHER

TRADES TO AVOID CONFLICTS.

9. FIELD VERIFY THE EXISTING CONDITIONS

AND MAKE ALLOWANCES FOR THE SAME.

10. VERIFY ALL ELECTRICAL SERVICE

REQUIREMENTS WITH THE UTILITY CO. AND

INCLUDE ALL WORK IN THE BID.

ALL BRANCH CIRCUITS SHALL HAVE AN

EQUIPMENT GROUNDING CONDUCTOR ROUTED

WITH THE CIRCUIT CONDUCTORS. THIS MEANS

ALL CONDUITS MUST HAVE A "GREEN" WIRE

INSTALLED THAT IS SIZED IN ACCORDANCE

WITH N.E.C. ARTICLE 250.

1. REMOVE ALL EXISTING FIXTURES, DEVICES,

EQUIPMENT AND ASSOCIATED WIRING IN

CONFLICT WITH CONSTRUCTION.

2. FIELD VERIFY THE EXISTING CONDITIONS

AND MAKE ALLOWANCES FOR SAME.

3. EXISTING OUTLET BOXES AND CONDUIT

MAY BE USED AS LOCATION PERMITS.

4. PATCH AND REPAIR WHERE REQUIRED BY

REMOVAL OF EXISTING ELECTRICAL ITEMS.

2

'LBL''KBR'

'L

1A

'

E0

E1 E2 E3

E5

E6

E7

E8 E9 E10E11 E12 E13 E14

E15

E16

22

E17E18E18

1 1 1 1

2222

3

E4E4

E0

E3

E4

E6E8

E9

2

E11

ELEC. CHARACTERISTICS

EQUIPMENT

WIRING REQUIREMENTS CIRCUIT

BOSTON MARKET EQUIPMENT SCHEDULE

MARK

MARK

EQUIP.REF.

* CONTRACTOR TO VERIFY ALL UTILITY REQUIREMENTS OF EQUIPMENT PROVIDED PRIOR TO ROUGH-IN.

* ALL DISCONNECTS SERVING 'KITCHEN' EQUIPMENT SHALL BE EQUAL TO HUBBELL #HBLDS SERIES. AMPACITY AS REQUIRED.

E11

E10

E8

E9

E7

E6

E5

E4

E3

E1

E12

E13

E14

E15

E16

E17

E18

REACH-IN FREEZER, 1-DOOR 115V, 1Ø, 9.0A

REACH-IN REFRIGERATOR, 1-DOOR

115V, 1Ø, 6.0A

25 QT. MIXER 115V, 1Ø, 11.0A, 3/4HP

E2

P.O.S. TERMINAL & PRINTER 120V, 1Ø

LOW TEMPERATURE HOLDING CABINET, 750-S 208-240V, 1Ø, 3.9A, 810W NEMA 6-15 RECEPTACLE 24" A.F.F.

FOOD WARMER WITH INSERT 120V, 1Ø, 3.3A, 400W

HOLDING CABINET, DOUBLE STACK, 1000-UP 208V, 1Ø, 7.0A, 1400WNEMA 6-15 RECEPTACLE 24" A.F.F.

(2) CONVECTION OVEN115V, 1Ø, 5.0A, 1/3HP

GAS RETHERMALIZER120V, 1Ø, 3.0A

FOOD WARMER 120V, 1Ø, 15.0A, 1800W

ROTISSERIE OVEN, DOUBLE STACKED 115V, 1Ø, 2.2A, 250W

PROGRAMMABLE TIMER

115V, 1Ø, 20VA

(2) MICROWAVE 208-240V, 1Ø, 21.2A, 4400W

NEMA 6-30 RECEPTACLE 24" A.F.F.

(2) LOW TEMPERATURE HOLDING CABINET, 300-S 120V, 1Ø, 6.7A, 800W

HOT WATER DISPENSER NEMA 14-20 RECEPTACLE 60" A.F.F.208V, 1Ø, 19.5A, 4000W

DUAL TEMPERATURE REACH-IN 115V, 1Ø, 7.5ANEMA 5-15 RECEPTACLE 84" A.F.F.

MEGA TOP REFRIGERATOR 115V, 1Ø, 7.2A

3-WELL HOT FOOD TABLE 120V, 1Ø, 10.0A, 1200W

E0 REACH-IN REFRIGERATOR, ROLL-IN, 2-DOOR 115V, 1Ø, 9.5A NEMA 5-15 RECEPTACLE 84" A.F.F.

L3E-5

L3E-7

L3E-37,39

L32-9

L32-10

5270

5290

5279

3336

9005

3506

3890

3826

1140

3530

3800

3040

3303

3518

3981

3309

5389

5349

3825

NEMA 5-15 RECEPTACLE 84" A.F.F.

NEMA 5-15 RECEPTACLE 84" A.F.F.

NEMA 5-15 RECEPTACLE 48" A.F.F.

QUADRUPLEX RECEPTACLE 24" A.F.F.

NEMA 5-15 RECEPTACLE 48" A.F.F.

NEMA 5-15 RECEPTACLE 48" A.F.F.

NEMA 5-15 RECEPTACLE 24" A.F.F.

NEMA 5-15 RECEPTACLE 24" A.F.F.

NEMA 5-15 RECEPTACLE 24" A.F.F.

NEMA 5-15 RECEPTACLE 24" A.F.F.

NEMA 5-15 RECEPTACLE 24" A.F.F.

NEMA 5-15 RECEPTACLE 24" A.F.F.

NEMA 5-15 RECEPTCEL 24" A.F.F. L32-11

L3E-3

L3E-1

L3E-6

9000

L3E-17,19,21

L3E-9,11

L3E-13,15

L3E-14,16,18

L3E-20,22

L3E-24

L3E-30,32

ELEC. CHARACTERISTICS

EQUIPMENT

WIRING REQUIREMENTS REMARKSCIRCUIT

QDOBA EQUIPMENT SCHEDULE

MARK

MARK

EQUIP.REF.

* CONTRACTOR TO VERIFY ALL UTILITY REQUIREMENTS OF EQUIPMENT PROVIDED PRIOR TO ROUGH-IN.

* ALL DISCONNECTS SERVING 'KITCHEN' EQUIPMENT SHALL BE EQUAL TO HUBBELL #HBLDS SERIES. AMPACITY AS REQUIRED.

E7

E6

E5

E4

E3

E1 DOUBLE-SIDED GRIDDLE 120V, 1Ø, 15.0A

3-BAY HOT FOOD TABLE

208V, 1Ø, 12.48A

CONVECTION STEAMER 208V, 3Ø, 22.0A

E2

WARM/HOLDING CABINET 120V, 1Ø, 10.0A, 1500WNEMA 5-15 RECEPTACLE 18" A.F.F.

WARMING DRAWER 120V, 1Ø, 7.5A, 900W

REFRIGERATED SALAD TOP W/HEATER 120V, 1Ø, 9.0A

FOOD WARMER 120V, 1Ø, 10.0A, 1200W

E0 TIMER 115V, 1Ø, 0.5A, 1/2HP NEMA 5-15 RECEPTACLE-VERIFY HEIGHT LBL-10

LBL-14,16

LBL-2,4,6,8

LBL-26

LBL-10

LBL-24

LBL-18200

143

136

130

125

113

108

107

NEMA 5-15 RECEPTACLE 18" A.F.F.LBL-12

NEMA 6-20 RECEPTACLE 18" A.F.F.

NEMA L15-30 RECEPTACLE 48" A.F.F.SHUNT-TRIP C/B

NEMA 5-15 RECEPTACLE 18" A.F.F.

E8 UNDERCOUNTER FREEZER 120V, 1Ø, 5.5A LBL-24204

E9 ICE MACHINE 115V, 1Ø, 13.2ANEMA 5-20 RECEPTACLE 24" A.F.F.

LBL-28606

E10 SAFE 120V, 1Ø, 1.5A LBL-20650

E11 P.O.S. SYSTEM 120V, 1ØNEMA 5-15 QUAD. RECEPTACLE 24" A.F.F.

LBL-201278

NEMA 5-15 RECEPTACLE 18" A.F.F.

NEMA 5-15 RECEPTACLE 18" A.F.F.

NEMA 5-15 RECEPTACLE 18" A.F.F.

NEMA 5-20 RECEPTACLE 18" A.F.F.

PROVIDE POWER CORD AND

PLUG (6'-0" MIN. LENGTH)

EXISTING PANEL TO

REMAIN. TYPICAL UNLESS

NOTED OTHERWISE.

'L3L' 'L3C' 'L3R'

'H3'

'L3'

STORE

CONTROL

PANEL

'L32'

'L3E'

EF-2

EF-1

MAU-1

ON ROOF

ON ROOF

ON ROOF

4

KH-1

KH-2

5

6

6

77

NOTE:

ALL 15- AND 20-AMP RECEPTACLES

SERVING KITCHEN AND PREP

AREAS SHALL BE GFCI PROTECTED.

LBL-22

LBL-13

L3E-2

GAS VALVE

LBL-17

GAS VALVE

L3E-26

L3E-13,15

L3E-20,22

L3E-20,22

L3E-33,35

NOTE TO ELECTRICAL CONTRACTOR:

UTILIZE EXISTING PANEL 'L1A' FOR CIRCUIT(S) SERVING

BOSTON MARKET SPACE, WHERE MADE AVAILABLE BY

DEMOLITION OF MANCHU WOK EQUIPMENT, IN LIEU OF

SERVING EQUIPMENT FROM PANEL 'L3E' OR 'L32' AS

NOTED. REMOVE BRANCH CIRCUIT OF DEMOLISHED

EQUIPMENT BACK TO PANEL, AND RE-USE CIRCUIT

BREAKER FOR NEW BOSTON MARKET EQUIPMENT AS

CONDITIONS ALLOW. CONTRACTOR TO FIELD VERIFY

NO OTHER LOAD(S) ARE ON CIRCUIT(S) BEING

DEMOLISHED PRIOR TO REMOVAL.

A NEW PANELBOARD SCHEDULE SHALL BE PRODUCED

AND CIRCUITS CLEARLY LABELED FOR ALL PANELS

AFFECTED IN RENOVATION, ('L1A', 'L3E', AND 'L32').

E12 WORKTOP FREEZER 120V, 1Ø LBL-29221NEMA 5-20 RECEPTACLE 24" A.F.F.

E12

E10E7E2E1E5

E5

1

2 2 2 2

1 1 1

3

LBL-35

JJ

E19 POWERSOAK SINK 208V, 3Ø, 26.7A, 2HP, 7000W4623DIRECT-WIRE THROUGH CONTROL L32-12,14,16

1

E19

1

PROJECT:

Design. Spaces. People.

Fort Worth, Texas 76104

www.qarch.comfx. (817) 738-9524ph. (817) 738-8095

707 W. Vickery Blvd. #101

SOLICITATION ISSUE

04/15/16 95% SUBMITTAL

CDI

ARMY AND AIR FORCE EXCHANGE SERVICE

CONVERT :

TO BOSTON MARKET /

QDOBA

FT. CAMPBELL, KY

SCALE:

AFFES NO:

DATE:

2146-15-000007

AS NOTED

SHEET:

DRAWING TITLE:

DRAWING PROJ. NO.

16014

23 JULY 2016

05/23/16

SOLICITATION

ISSUE

CDI

06-23/16ADDENDUM #1

CDI

E-101

POWER PLAN

kconway
Pen
Kalona
kconway
Pen
6/23/16