7/26/2019 Call Station
1/16
www.commend.com
1 2
SIP-WS 200VSIP-WS 210V
Datasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 1|16
DATASHEET
Full Duplex capable, vandal resistant SIP stations de-
signed for areas with high requirements on safety. The
stations are connected directly to the Ethernet (LAN/
WAN) and in this manner are connected to a compa-
tible SIP Server via the IP-network. The built-in switch
with downlink function allows direct connection of an
additional IP-device (e.g. an IP-camera).
Besides high volume, the SIP stations provide a numer-
ous amount of further features: Pre-recorded audio can
be applied in a multi-purpose manner, e.g. as acoustic in-dication at line fault or as waiting information at call initia-
tion, a confgurable background noise canceller provides
a crystal clear communication in challenging situations.
Furthermore, the stations are perfectly suited for use as
door stations at entry- and gateways, due to integrated
relay outputs.
The 3 mm stainless steel front panel with tamper protec-
tion and special screws protects against vandalism. The
robust construction provides full protection against water,
dirt and dust protection class IP 65. Each button can be
allocated to a call number and the relevant label area can be
lled in individually. The red emergency call button is easilyvisible from a considerable distance and can be activated
quickly in emergency situations.
SIP Stations SIP-WS 200V / SIP-WS 210V
SIP-WS 201V (not pictured)1.
SIP station with one programmable, back-lit direct dialling
button, electret microphone with multifunction LED, loud-
speakers 2 x 8 , built-in amplier class D 2.5 W,2 relay
outputs (connection as make or break contact), protec-
tion classication IP 65 and IK 09, material stainless steel.
SIP-WS 202V (not pictured)
SIP station like SIP-WS 201V but with 2 programmable,
back-lit direct dialling buttons.
SIP-WS 203V
SIP station like SIP-WS 201V but with 3 programmable,
back-lit direct dialling buttons.
SIP-WS 211V (not pictured)2.
SIP station with one programmable, back-lit emergency call
button, electret microphone with multifunction LED, loud-
speakers 2 x 8 , built-in amplier class D 2.5 W,2 relay
outputs (connection as make or break contact), protec-
tion classication IP 65 and IK 08, material stainless steel.
SIP-WS 212V
SIP station like SIP-WS 211V but with an additional program-
mable, back-lit direct dialling button.
7/26/2019 Call Station
2/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 2|16
DATASHEET
Technical Data Benefts
TECHNICAL DATAIP rating: IP 65
Mechanical impact resistance acc. EN 62262:
SIP-WS 200V: IK 09 SIP-WS 210V: IK 08
Front panel: stainless steel, 3 mm (0.12 in)
Operating temperature range: 20 C to 70 C (4 F to 158 F)
Storage temperature range: 20 C to 70 C (4 F to 158 F)
Relative humidity: up to 95% not condensing
Call button: 1 3 direct dialling buttons only SIP-WS 210V:large red emergency call button
Microphone: Omnidirectional electret microphone for
max. 7 m (23 ft) speaking distance
Loudspeaker: Special membrane type for optimal sound
quality, sound pressure: 85 dB/1 W/1 m (3.28 ft), 2 x 8
Amplier: Built-in amplier class D with 2.5 W
Status indication: red LED
Outputs: 2 SPDT (changeover) relay outputs
30 V / 1 A: 100,000 make-and-break cycles
RAM Memory: 32 MByte
Flash Memory: 8 MByte
DTMF Decoding: RFC 2833
SIP User Agent (UDP): RFC 3261
IP Protocol: IPv4, TCP, UDP, HTTP, RTP, RTCP DHCP, SNMPv2
Frequency range: 300 - 3,400 Hz
Connection: pluggable screw terminals
- IP Uplink/Downlink: shielded RJ 45 modular jacks
Cabling: min. Cat. 5
Power supply: 24 VDC 2 V, 500mA or PoE
Power consumption:
1.4 W idle
approx. 1.7 W at conversation (depending on volume)
PoE (Power over Ethernet): IEEE 802.3af standard
Power consumption of the terminal device:
Class 0 (0.44 W to 12.95 W)
Codecs: G.711 a-Law
G.711 -Law
prepared for G.722
Ethernet: 2 x 10/100 MBit/s (full/half Duplex)
Additional mounting material: ush mount kit WSFB 50V ush mount kit WSFB 50V FL surface mount kit WSSH 50V
rain protection roof WSRR 50V
Measurements: with ush mount kit WSFB 50V:W 164 mm (6.46 in), H 279 mm (10.98 in), D 14 mm (0.55 in)
with ush mount kit WSFB 50V FL:W 164 mm (6.46 in), H 279 mm (10.98 in), ush with plaster
with surface mount kit WSSH 50V:W 164 mm (6.46 in), H 279 mm (10.98 in), D 50 mm (1.97 in)
Weight incl. package: approx. 1500 g (3.3 lbs)
SYSTEM REQUIREMENTS
Compatible SIP Server (see page 5) or
G8-VOIPSERV (for additional features)
EXTENT OF SUPPLY
SIP station
Screws for mounting
Series SIP-WS 210V: 3 x paste-on label (SOS /
EMERGENCY / HELP) for emergency call button
Short reference
BENEFITSVandal resistant
IP rating IP 65 and mechanical impact resistance up to IK 09
Very high volume
Full Duplex for natural, hands-free communication
SNMP for surveillance of the station
Using Pre-recorded audio as:
Waiting information at call initiation
Individual call tone for call initiation
Location message
Acoustic indication at line fault
Control of the 2 relays e.g. as door opener via
DTMF post-dial or
Web
Attendant contacts for various functions, e.g.
Additional signalisation while ringing, during a call or in case
of malfunction
Operation without Server possible
Congurable Acoustic Echo Canceller (AEC)
Congurable Background Noise Canceller
Adaptive jitter buffer
Complies with SIP standard for easy integration in every SIP
capable PBXes
Integrated webserver for conguration & rmware update
Adjustment of microphone sensitivity and volume
Flexible operation via Power over Ethernet or via external
power supply
3.4 kHz speech quality for optimum intelligibility and
compatibility
Increased system availability by redundant LAN infrastructure
The integrated data switch function enables the connection of
further IP devices, e.g. IP camera
Congurable Auto Answer Function
Instant boot (system boot within seconds)
Communication via IP-data networks no additional cabling
required
Congurable backlight
7/26/2019 Call Station
3/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 3|16
DATASHEET
Typical Applications
SIP
0 #*
SIP
0 #*
Telephone
Call Center
IP NETWORK
Server
EMERGENCY SYSTEMS AT HIGHWAYSA typical application for use of SIP stations are emergency systems at highways.
The SIP stations integrated in helppoints are connected to the appropriate SIP server and a call center over the IP network.
A possible line fault is indicated acoustically via pre-recorded audio and can be processed by the SIP Server.
SIP
0 #*
Telephone
IP NETWORK
Server
OPERATION AS DOOR STATION
Due to integrated relay outputs it is possible, to use the SIP stations as door stations (with door opener contacts) at entry- and gate-
ways. The door opener contacts can be controlled by means of DTMF post-dialling or via web.
7/26/2019 Call Station
4/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 4|16
DATASHEET
Typical Applications
SIP
0 #*
Telephone
IN SMALLER SYSTEMSDue to the open standard of the SIP protocol, the stations can be operated without server. Therewith, cost-efcient use of the stations
in smaller systems is enabled.
7/26/2019 Call Station
5/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 5|16
DATASHEET
Compatibility
COMPATIBILITY SIP PBXBasically the SIP stations can be used with any SIP server.
The following server types have been tested explicitly by Commend and therefore a proper functionality can be conrmed:
MANUFACTURER* TYPE VERSION
Digium Asterisk Version 1.2, 1.4, 1.6
CiscoCisco Call ManagerCisco Unied Communication Manager
Version 5 or higher
Nortel CS1000 Version 6
Innovaphone Virtual Appliance IPVA Version 9 nal
Alcatel OmniPCX Enterprise OXE
Siemens Hipath 4000 Version 5
3CX 3CX for Windows 3CX PhoneSystem 9
Starface Starface free Version 4.6.5.1
Aastra MX-ONE Version 4.1 SP 1
VOIP PROVIDER TYPE VERSION
Sipgate Sipgate.at, Sipgate.de December 2010
Vodafone Arcor Vodafone.de January 2011
blueSIP blueSIP.net May 2011
*The listed products and company names are brand names or registered trademarks of their respective owners.
7/26/2019 Call Station
6/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 6|16
DATASHEET
Installation
PRECAUTIONSWhen opening the stations ESD precautions must be observed.
The stations may only be opened by authorised service engineers.
CONNECTION
Attention:
It is mandatory to ensure a correct power supply of the SIP station: min. 22 VDC,max. 26 VDC
PoE has to be connected to the RJ 45 jack IP Uplink (see above).
Further IP devices can be connected to the RJ 45 jack IP Downlink (see above), like e.g. an IP camera.
But it is also possible to link up to 20 SIP-WS 2xxV in series via this ethernet interface.
Attention Use of PoE:
If multiple SIP-WS 2xxV are connected in series, then only the 1st device can be supplied with Power over
Ethernet. All other devices (connected in series) must be supplied separately by an external power supplyunit.
CONFIGURATION VIA WEBINTERFACE
Via the integrated webinterface , it is possible to congure optional direct dialling numbers for the buttonsof the SIP-WS 2xxV.
OUT 2
OUT 2
OUT 1
OUT 1
DC+
DC
IP Uplink+ PoE
Alternative
power supply
24 V DC 2 V
Slots for inserting
button labels
FactoryResetbutton
IP Downlink(e.g. IP-camera)
7/26/2019 Call Station
7/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 7|16
DATASHEET
Installation
160 (6.3)
140 (5.5)
275
(10.
84)
255
(10.
05)
4x
7
(0.28)
Front panel thickness: 3 (0.12)
MEASUREMENTS FRONT PANELMeasurements in mm (inch), not to scale!
7/26/2019 Call Station
8/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 8|16
DATASHEET
Installation Additional Mounting Material
MRMR
MR
12x Expansion openings (can be broken out) 21
150 (5.91)
135.6 (5.34)
82 (3.23)1 (0.04) 0.5
(0.02)45.5
(1.79)
15
(0.59)
(0.5
9)
265
(10.
44)
(0.
55)
15
250.
6
(9.
87)
(0.3)
4x
7.5
164 (6.46)
279
(10.
99)
14
MR .... Flush mount frame (metal)
with mounting frame (plastic)
Cutout for flush mount box:137 (0.45) x 252 (0.83)
197
(7.
76)
front flush with plaster
MEASUREMENTS FLUSH MOUNT BOX WSFB 50VMeasurements in mm (inch), not to scale!
EXTENT OF SUPPLY
Flush mount box plastic (incl. cavity wall claws & cover lid)
Mounting frame plastic (incl. mounting screws)
Flush mount frame metal & gasket
Cable xing brackets (incl. screws)
Short reference
Weight incl. package: approx. 540 g (1.2 lbs)
7/26/2019 Call Station
9/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 9|16
DATASHEET
MOUNTING FLUSH MOUNT BOX WSFB 50V
5
1
3
4
2
1
1
2
3
4
6
6
5
..... Front panel (metal) with station electronics
MOUNTING
DIRECTION
..... Mounting frame (plastic)
..... Flush mount frame (metal)
..... Gasket
..... Flush mount box (plastic)
To corresponding expansion openingof
flush mount boxof e.g. WS expansion module
..... Connection spacer (with gaskets) for connecting two flush mount boxes andfor cable feed through
Illustrationfront panel
*
Screw front panel onto flush mount frame
Screw mounting frame together with the flush mount frame (metal) and the gasket onto the flush mount box
(screws in extent of supply)
If possible, then 2 connection spacers shall be used per expansion (at deppened openings, see above)
gasket
gasket
For cavity wall mounting or installation in a desk, the cavity wall claws have to be used.
(wall thickness: 5 mm to 30 mm / 0.19 in to 1.18 in)
Installation Additional Mounting Material
7/26/2019 Call Station
10/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 10|16
DATASHEET
EXTENT OF SUPPLY
Flush mount box plastic with mount frame metal (incl. cover lid)
Cable xing brackets (incl. screws)
Short reference
Weight incl. package: approx. 540 g (1.2 lbs)
(0.5
9)
15
12x Expansion openings (can be broken out) 21
164 (6.46)
279
(10.9
9)
251.
6
(9.8
8)
22(8.87)
53 (2.09)
136 (5.35)
front flush with plaster
Installation Additional Mounting Material
MEASUREMENTS FLUSH MOUNT BOX WSFB 50V FLMeasurements in mm (inch), not to scale!
7/26/2019 Call Station
11/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 11|16
DATASHEET
1
2
1
2
..... Front panel (metal) with electronics and gasket
..... Flush mount box (plastic) with Flush mount frame (metal)
...this side up, mounting direction
Illustrationfront panel
*
Screw front panel onto flush mount frame
Install the flush mount box by moulding into plaster or concrete.Do not remove plaster cover until the flush mount box is mounted.
MOUNTING FLUSH MOUNT BOX WSFB 50V FL
Installation Additional Mounting Material
7/26/2019 Call Station
12/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 12|16
DATASHEET
279
(10.
99)
200(
7.
88)
164 (6.46)
(0.87)
148 (5.83)
50 (1.97)
229
(9.
02)
114 (4.49)
4x 5 (0.2)
6x
22
218
(8.
58)
60 (2.36)
4x Mounting openings 6 (0.24)
MEASUREMENTS SURFACE MOUNT BOX WSSH 50VMeasurements in mm (inch), not to scale!
Installation Additional Mounting Material
EXTENT OF SUPPLY
Surface mount box metal (incl. 6 x dummy plugs)
Plastic box
4 x IP 65 cable feed through
2 x sabotage plates (currently not applicable for SIP stations)
Wall mount kit (screws, dowels, gasket rings and washers)
Cable xing brackets (incl. screws)
Short reference
Weight incl. package: approx. 945 g (2.08 lbs)
7/26/2019 Call Station
13/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 13|16
DATASHEET
31
2
4
2
1
4
3
2
..... Front panel (metal) with station electronics
..... Plastic box
Screw the front panel onto the surface mount box
Press the plastic box into the surface mount box
Illustrationfront panel
*
..... IP 65 cable feed through
..... Surface mount box (Metal)Mounting via wall mounting kit
(screws and dowels) in extent of supply
The cable feed through can be put into the plastic box
after breaking out the expansion openings
(installation cable feed through see picture to the right).
Snap in
Insert cable
Pull back tight
MOUNTING SURFACE MOUNT BOX WSSH 50VAttention:
The dummy plugs for the surface mount box (in extent of supply) can not be removed without opening the housing!
Installation Additional Mounting Material
7/26/2019 Call Station
14/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 14|16
DATASHEET
Installation Additional Mounting Material
164 (6.45) 80 (3.15)
foam strip, approx. 2 mm (0.08 in)
277
(10.
9)
MEASUREMENTS RAIN PROTECTION ROOF WSRR 50VMeasurements in mm (inch), not to scale!
EXTENT OF SUPPLY
Rain Protection Roof
Fixing screws
Short reference
Weight incl. package: approx. 465 g (1.03 lbs)
7/26/2019 Call Station
15/16
SIP-WS 200V / SIP-WS 210V
www.commend.comDatasheet Version 1.0/0711 |Errors and omissions excepted |Products may change in the interest of technical improvements without notice. P 15|16
DATASHEET
Installation Additional Mounting Material
MOUNTING RAIN PROTECTION ROOF WSRR 50VNote:
The rain protection roof can be used for vandal resistant SIP stations in surface mount version and in ush mount version. Following
illustration shows the installation of the rain protection roof WSRR 50V to the surface mount kit WSSH 50V.
Remove the screws with which the station front panel is mounted
Afterwards, screw the rain protection roof with the station front panel onto the surface mount box or the ush mount
frame by using the xing screws in the extent of supply (see above).
Fixing screwsrequired for
WSRR 50V (in extent of supply)
Rain protection roof
WSRR 50V
Front panel (metal) with
station electronics
Example:
Surface mount kit WSSH 50V
7/26/2019 Call Station
16/16
SIP-WS 200V / SIP-WS 210VDATASHEET
AUSTRIA
SLOVENIA
RUSSIA
Commend sterreich GmbHTel. +43-1-715 30 79www.commend.at
CROATIA
SERBIA
BOSNIA-HERZEGOVINA
Commend Adria d.o.o.Tel. +385-1-369 11 23www.commend.hr
FRANCE Commend France S.A.S.Tel. +33-149 18 16 40
www.commend.fr
NETHERLANDS
BELGIUM
LUXEMBURG
Commend B.V.Tel. +31-76-200 01 00
www.commend.nl
ITALY Commend Italia S.R.L.Tel. +39-035-95 39 63www.commend.it
SWITZERLAND
LIECHTENSTEIN
Commend AGTel. +41-44-955 02 2 2www.commend.ch
Europe
SINGAPORE Commend Business Hub AsiaIsolectra Far East Pte. Ltd
Tel. +65-62 72-2371
www.commend.com.sg
CHINA Commend Business Hub ChinaIsolectra China
Tel. +86-21-52 13 19 28
www.commend.cn
Asia
USA
CANADA
LATIN AMERICA
Commend Inc.Tel. +1-201-529-2425www.commendusa.com
America
AUSTRALIA
NEW ZEALAND
Commend AustraliaTel. +61-3-9755-39 47www.commend.com.au
Oceania
ISRAEL Sberlophone LtdTel. + 972-4-834 10 32www.sberlophone.co.il
Middle East
Commend International GmbHTel. +43-66 2-85 62 25www.commend.com
Other countries
SWEDEN
NORWAY
FINLAND
DENMARK
ICELAND
JNT Sound System ABTel. +46-8-99 30 6 0www.jnt.se
GERMANY Schneider Intercom GmbHTel. + 49-211-88285-3 33
www.schneider-intercom.de
POLAND C&C Partners Telecom Sp.z o.o.Tel. +48-65-5 25 55 55
www.ccpartners.pl
UNITED KINGDOM
IRELAND
Commend UK LtdTel. +44-1279-87 20 20
www.commend.co.uk
SLOVAKIA
CZECH REPUBLIC
Commend Slovakia spol. s r.o.Tel. +421-2-58 10 10 40www.commend.sk
SPAIN
PORTUGAL
Commend Ibrica S.L.Tel. +34-91-395 24 98 (Madrid)
Tel. +34-93-567 76 79 (Barcelona)
www.commend.es
SOUTH AFRICA Commend Business Hub South AfricaEvolving Management Solutions (Pty) Ltd
Tel. +270-112-746 66 5
www.commend.co.za
ALGERIA
TUNISIA
MOROCCO
Commend France S.A.S.Tel. +33-149 18 16 40
www.commend.fr
Africa
COMMENDA Strong Network |Worldwide