4
Procon Engineering (A Division of National Oilwell Varco UK Limited) Type IT8000Ex W & M Approved Weighing Terminal For use in Ex Zones 1, 2, 21 and 22 Stainless steel IP65 housing W & M approved – 6000d single or multiple range Numerical keypad for input of tare weight and ID’s with function keys for zero setting, taring & printing Optional I/O and serial interfaces 4 x 20 character alphanumeric back-lit LCD text display Storage of up to 450,000 weighing records Industrial design, modular concept, proven standard programmes and free programmability make the IT8000Ex the ideal weighing terminal for: Shipping and receiving scales Batching and recipe weighing Filling controllers for drums or IBCs Weighing installations with customised operating sequences

Calibri IT8000Ex W&M Weighing Terminal - Dezrez€¦ · Procon Engineering (A Division of National Oilwell Varco UK Limited) Type IT8000Ex W & M Approved Weighing Terminal For use

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

  • ProconEngineering(ADivisionofNationalOilwellVarcoUKLimited)

    TypeIT8000ExW&MApprovedWeighingTerminalForuseinExZones1,2,21and22

    StainlesssteelIP65housing W&Mapproved–6000dsingleor

    multiplerange NumericalkeypadforinputoftareweightandID’swithfunctionkeysforzerosetting,taring&printing

    OptionalI/Oandserialinterfaces

    4x20characteralphanumericback-litLCDtextdisplay

    Storageofupto450,000weighingrecords

    Industrialdesign,modularconcept,provenstandardprogrammesandfreeprogrammabilitymaketheIT8000Extheidealweighingterminalfor:• Shippingandreceivingscales• Batchingandrecipeweighing• FillingcontrollersfordrumsorIBCs• Weighinginstallationswithcustomisedoperatingsequences

  • IT8000ExW&MApprovedWeighingTerminalTechnicalSpecificationSheetStainlesssteelhousingIP65Suitableforharshenvironment.Withmountingbracketsfordesktop orwall-mountinstallation.Allcablesconnectedthroughtightcableglands.KeyboardFunctionkeysforzerosetting,taringandprinting.NumerickeypadforinputoftareweightsandIDs.Alphanumericentriespossibleviamultiplekeyassignment.Application-specificfunctionsdirectlyaccessibleviafunctionkeys

    LCDtextdisplayForweight,multi-lingualoperatorpromptsandcalibration.Withbacklighting,uptofourlinesofalphanumericdisplaywithupto20characterseach.Powersupply24VDCEx“e”or230VAC.

    WeighingElectronicsScaleinterfaceforonescalebasewithupto4loadcellswithanimpedanceof3500hmeachor8loadcellswith10000hm.WeightsandMeasuresapprovedsolutionof6000dwithamaximumpreloadof80%.Calibrationispossibleassingleormultiple-rangescale.(e.g.3x3000d)andassingleormulti-intervalscale.Internaldataarchiveforthestorageofupto450,000weighingrecords.

    ModularconceptThemodulardesignprovidesforseveralconfigurationswith:§ Upto2serial,intrinsically

    safeinterfacesfortheconnectionofprinter,PC,PLCremotedisplay,scannerorfieldbus/Ethernetgateway.

    § FlexibleI/Oconceptwith4digitalinputs(5V,intrinsicallysafe)andseveraloptionsfordigitaloutputs:5VDC,intrinsicallysafetoconnectpiezo-electricvalvesorpotential-freerelaycontactstoconnectintrinsicallysafe24Vsolenoidvalves.

    Thisensuresthattheoptimalsystemconfigurationcanbechosen,forstationaryaswellasmobileuse.SpecificsoftwaremodulessupporttheconnectionofPCs,printers,PLCsandfrequencyinvertersinsafearea.

    FreeprogrammabilityStandardprogrammescanbeadaptedtotherequirementsofspecificapplication.NewprogrammescanbedesignedinaverysimplewayonaPCwiththeRTCprogrammedevelopmentenvironment.HighoperationalsecurityFastanderror-freeoperationisensuredbyahigh-contrastalphanumerical,back-litLCDfortheindicationofweight,IDsandoperatorpromptsincombinationwithaneasy-to-usetactilekeyboardfortheentryofmanualtareandadditionaldata.

  • ProconEngineering(ADivisionofNationalOilwellVarcoUKLimited)

  • ProconEngineering(ADivisionofNationalOilwellVarcoUKLimited)

    ATEXapproval

    II2(2)GExeibmb(ib)IICT4Gb(Gas)II2(2)DExibtb(ib)IIICTI25°CDbIP65(Dust)Construction

    Stainlesssteelhousingwithmountingbracketsfordesk-top,wall-mountorpanel-mountinstallation.Displayandkeyboard

    4x20-characteralphanumericback-litLCDdisplay,heightofcharactersforweightindication19mm(0.7”),operatorpromptsandcalibrationvia20-charactertextdisplay.Keyboardwithnumerickeysfortheinputoftareweightsandadditionalinformation,scalekeysforzerosettingandtaringandfunctionkeys.Inputofalphacharactersviamultipleassignmentofkeys.Weighingelectronics

    Fortheconnectionofloadcellswithanimpedance87.5–3,3000hm(e.g.4x3500hm).W&Mapprovedresolution6000d,intervalresolution524000d,inputsignal0.33µV/e.CalibrationSetupassingleormultiplerangescaleorasmulti-intervalscale.Calibrationwithtestweightsorthroughentryofratedsignal,optionforlinearisation.Powersupply

    Options:

    § 230VACpowersupplyunitmountedonbackcover

    § External24VDCpowersupplyunitforinstallationsafearea

    § External12VDCrechargeableExbattery

    Operatingtemperature-10°C(+14°F)to+40°C(+104°F),95%relativehumidity,non-condensing.

    Interfaces

    § 4digitalinputs(5VDC,intrinsicallysafe).

    § Asoption4digitaloutputs(5V,intrinsicallysafeorpotentialfreerelaycontactsforconnectiontointrinsicallysafe24Vsolenoidvalves).

    § Asoption2serialinterfaces,intrinsicallysafe,forconnectiontointerfaceseparationmodule.

    InterfaceseparationmoduleCanbefittedwithRS232,20mACLorRS485interfacedrivers.Powersupplyoptional110-240VACor24VDC.ATEXapproval:

    II(2)G(ExibGb)IIC(Gas)II(2)D(ExibDb)IIIC(Dust)

    Dimensions&accessories:

    .

    FreeProgrammabilityComprehensive,PC-basedRTGWINprogrammedevelopmentandtestenvironmentincludingprogrammegenerator(CASEtool),PascalandPLCinstructionlists.

    OptionFieldbus/EthernetConnectiontoProfibusDP,DeviceNetorEthernetpossibleviaexternalconverters,installedinsafearea.

    OtherOptions

    § Exloadcellcable§ Exdatacable§ Exloadcelljunctionbox

    (JunctionBoxEx)ATEXII2(2)GExib[ib]IICT4Gb(Gas)II2(2)DExib[ib]IIICT50°CDb(Dust)II3GExnAIICT4Gc(Dust)II3DExtcIIICT50°CDc(Dust).