CALCULO DE CAUDAL PROYECTADO A 20AÑOS(Q)
DATOSPOBLACION 1100 HABITDOTACION 140 L/HAB*DIA N°Q 154000 L/DIA 1Q 1.78E-03 m3/s 2TASA CRECIENTO 2% 0.02 3P.FUTURA 1634.54214 HABITQ 228835.899 L/DIAQ 2.65E-03 m3/s
CALCULO PARA TUBERIA
DATOSMATERIAL ACEROL 1000 m T ° 17 °CPi 2770 m
279222 m
hl 22 mVisc. Agua 1.15E-03 Pa/sDensidad 1000 kg/m3E1 0.009 mf asumido 0.02-0.1gravedad 9.8 m/s2
ACCESORIOS Y CONSTANTES
DATOSVALVULA DE ENTRADA 0.5CODOS 90° 0.9VALVULA CHECK 2.5
TOTAL 3.9
Po
)Z
PERDIDA DEL SISTEMAh1
D N° Re h20.02 0.0555 52818.203 0.136 hT
0.136 0.0815 35991.890 0.108 VELOCIDAD0.108 0.0779 37666.599 0.111 VELOCIDAD0.111 0.0782 37475.242 0.111 0.5508
DIAMETRO CALCULADO 0.077850.11123
VELOCIDAD CALCULADA 0.55076339029053
CATALOGO DE TUBERIA REALMATERIAL STEELDIAMETRO REAL 0.085 mDIAMETRO NOMINAL 1/2"RUGOSIDAD 0.012 m
N°-Re REAL34498.7016322771
0.125199139306051
VELOCIDAD REAL0.4667
f asumido f calculado
f CALCULADO
f REAL
PERDIDA DEL SISTEMA16.3715453959691
0.043348279619534316
CALCULO DE EFICIENCIA DE BOMBA
CAUDAL FUTURO Qf 0.0027 m3/sg
DatosGravedad 9.8pi 3.1416hl 22L 1000Po 2770P1 2792Densidad 1000E1 0.009 mm 0.00009 mViscosidad 0.00115 Tablas
ACCESORIOSks valvulas check 2.5 suma accesorios 3.9kd valvula de entrada 0.5kd codos 0.9 0.9 kd 2.3kd v. entrada 0.5v1 0.5508v2 0.4667f 0.0974603448370999
ls 50.9ld 9
D 0.0972
p atm 10.2 atm 105.366 m agua p man 0Hvp 0.01705 barr 0.1761265 m de agua
hd 10hs 1
CALCULO DE EFICIENCIA DE BOMBA
SUCCION POSITIVAHDT= 2808
HT 74.613hfs= 0.043
hfd= 16.372
habs 105.366
NpsHa 104.147 QNpsHa = Habs-Hs-hfs-hvp
%
0.0027 m3/s0.000 m3/s0.000 m3/h