Upload
tranthien
View
222
Download
0
Embed Size (px)
Citation preview
-
-
-
-
-
-
-
-
-
Chairman’s letter
Cables for every day,cables for all your life
Cables for every day, cables for all your lifewww.cablesrct.com
Production processThe effectiveness and quality requirements which
markets impose on electrical cables are part of our company’s personality. Our products must perfectly adapt to the highest quality requirements. And we must achieve this in a highly competitive environ-ment.
Thus, it is fundamental to count on the most modern technology, so that at the same time that physical and dimensional properties are being guaranteed, we can obtain the highest production at the lowest cost. At Cables RCT, we are familiar with these requirements and we have developed a complete production pro-cess which, based on the highest national and inter-national technologies, allows us to thoroughly control each and every phase of the production process.
Our production process starts with the most basic row materials, solid copper wire which proceeds di-rectly from the foundry, and the plastic component with which we elaborate our own composites. The initial processes of wiredrawing and jointing in which copper is adapted to the different compositions of our cables are crucial phases. We understand that it is es-sential to be able to control them, since a good copper
characteristics and dimensions are going to be within
Dimensional and production control are key factors at electrical wire manufacturing. At Cables RCT we can reach an accuracy of one ten-thousand of a mi-llimeter, so that we get at every moment a product which is in accordance with the requirements and de-mand of our customers.
Likewise important is to be able to count on the possibility of elaborating our own composites, as this eases the constant task of investigating and develo-ping in new products and formulations with which we can improve the properties of our cables. In this way, our production process is a complete process in which all relevant phases of manufacturing an electri-cal wire, including something apparently as trivial as packaging, are under our absolute control.
The production facilities of Cables RCT in Zaragoza allow us to dispose of an important production ca-pacity which, together with an advanced planning and logistic system, turn us into a reliable and capa-ble provider, capable to commit and reliable when it
able to supply cables for every day, with a production structure thought for all your life.
Introduction to the companyWe are an independent Spanish manufacturer of
low voltage electrical cable located in Zaragoza. With this catalogue we are aiming to present our current product range, oriented, as we like to say, to those cables which are sold every day and that expounds the bottom line of our business philosophy, based on
Cables for every day and cables for all your life.
Our history Our company started to produce in 1965, in the
commercial premises of a housing building in the city of Zaragoza. At the beginning rubber cables were made but they would soon be replaced by the PVC cables, a product which was starting to replace older techniques thanks to its excellent physical characteris-tics and process ease. At that time our company had another name:
SA Manufactureras RCT. This name has been chan-ged in 1990 with the current one of Cables RCT, when
with the product.
Long gone are those beginnings in which Mr. Gon-zalo Mateos, our president and founder, moved the company to a premise of bigger dimensions in 1967, but inside the city yet. Nonetheless, still we preserve
In 1973, the factory was moved to an industrial buil-
the good decision of aiming to the production of PVC
cables and their marketing through an organized dis-tribution was consolidated. Resting the responsibility of the delivery of our products on the distributors of electrical material, as a strategic commercial decision, has been and is one of the most important identity sig-ns of Cables RCT. How we work, our product range, commercial structure, all those fundamental factors are thoroughly marked and oriented by this decision.
Soon, the production and marketing requirements led to the needing of the production capacity expan-sion, and the factory moved to new facilities. There it remains to this day, the most important part of our production process, although in 1997 an adjoining building has been acquired, now known as RCT 2 where measure and storing jobs as well as adminis-tration and commercial attention department tasks are being carried out.
Currently, we dispose of logistical stores in Barcelo-na, Valencia and Seville, which together with our faci-lity in Zaragoza allow us to service all our customers far and wide the Spanish geography.
The productive facilities of Cables RCT in Zaragoza allow us to dispose of an important and consolidated production capacity, which together with a sophisti-cated system of planning and logistic, turns us into a capable and reliable provider, able to commit and
provider able to provide cables for everyday, with a production structure made for all life.
Cables for every day, cables for all your lifewww.cablesrct.com
LogisticModern industrial companies should consider the
logistics of their products as part of their production process. Ensuring the quality and the performance of the product is as important as ensuring its availability and providing a service in accordance with the cus-tomer expectations. The logistics of electrical equip-ment is based on an important network of distributors on which Cables RCT has always relied to get their cables to the installers, last users of our articles.
To support the distribution channel and to ease its work, Cables RCT counts with an important level of demand at its facilities in Zaragoza, from where shi-pments are being done every day to anywhere in the world. Apart from this central warehouse, we count with delegations in some of the main cities in Spain, from where we can attend our clients more closely, always backed on a complete system of integral and computerized logistics which allows us at any time, to dispose of an accurate and updated information about our storage level, its location and availability, being this way able to provide our customers with an imme-diate answer to any enquiry they might have. These delegations are supplied regularly and consistently
territory.
In the commercial proposal of Cables RCT, it is clear that product quality plays a fundamental role. The following services are also of a crucial importan-ce, since success cannot be achieved if we do not add the highest level of logistic demand to the technical and production excellence.
Quality environmentElectrical equipment, because of its omnipresence
in contemporary life and for being particularly sen-sitive material in safety matters, has always endured the highest standards of quality. Starting with the raw materials, through the various stages of the production
-hed product, the electric cables are perhaps one of the products on which safety and quality control reach their highest expression.
At Cables RCT, being aware of the importance for our customers and users of our products and of the inherent safety in electrical cables, we have followed since ever the last tendencies in safety assurance,
count with the one which, in our mind, should be the
-cordance with the UNE-EN ISO 9001. This regulation
the products of our company have been manufactured and distributed according to a thorough quality proto-col which, due to its holistic nature, contains all the critical processes of our management.
At Cables RCT we consider that quality is an ever-yone responsibility, thus usually tasks assigned to the quality department or lab are complemented with various self-control tasks distributed among each and every production stage so that we can guarantee that the raw materials, the process and the obtained results in each and every moment of the processes are ac-cording to the requirements of our internal procedure
and to those of the regulations of management quality and product.
-
accordance with the national and international regu-lations. Our cables, it could not be otherwise, count
-dically updated and monitored by the certifying au-thorities, which carry out inexorably, the perceptive auditory control, follow up and renewal, providing the assurance that our systems, so audited, are per-fectly adapted to all requisites of the most demanding regulations.
Using Cables RCT cables, entails the guarantee -
mark, with the security of counting with a company which supports its products, that holds that its cables for everyday are also cables which can be taken into account for all the life.
Our commitment has led us as well to develop an integral policy that comprises the environment issues as a fundamental part of our daily routine. As result of
UNE-EN ISO 14001 of Environment Management by AENOR. This way, our guarantee extends beyond the technical characteristics of the products themselves, and in an all-encompassing approach, our company assures the best and most respectful behavior with our environment.
Cables for every day, cables for all your lifewww.cablesrct.com
6
www.cablesrct.com
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/300V CablesH03VV-F ............................................ 7
300/500V CablesH05V-U .............................................. 8H05V-K .............................................. 9Tri-Rated H05V2-U .......................... 10Tri-Rated H05V2-K ........................... 11H05VV-F .......................................... 1205VV-F ............................................. 14H05VV5-F ........................................ 15H05V2V2-F ...................................... 17Arctic Grade ..................................... 18FR-N05 A05VV-U/R .......................... 19H05Z1-K (AS) ...................................21ES05Z-U (AS) ....................................22ES05Z1-K (AS) ..................................23H05Z-U ............................................24ES05Z-K (AS) ....................................25H05Z-K ............................................26H05Z1Z1-F (AS) ...............................2705Z1Z1-F (AS) ..................................29NYM-J / NYM-O ...............................30NHXMH ...........................................32
450/750V CablesH07V-U ............................................34H07V-R ............................................35H07V-K ............................................36Tri-Rated H07V2-U .......................... 37Tri-Rated H07V2-K ...........................38H07Z1-K(AS) ....................................39H07Z-U ............................................40H07Z-R ............................................ 41H07Z-K ............................................ 42ES07Z-U (AS) .................................... 43ES07Z-R (AS) ....................................44ES07Z-K (AS) ....................................45TRIPLÍN® H07V-U ............................46TRIPLÍN® H07V-K ............................. 47TRIPLÍN® H07Z1-K (AS) ....................48Triplex H07Z1-K (AS) .......................49
0,6/1kV CablesVV-K .................................................50RV .................................................... 52R2V ..................................................54VVFV-K ............................................56RVFAV ..............................................58RVFV ................................................ 59RVFV Stainless steel .......................... 61RVFAV-K ...........................................62RVFV-K .............................................63RVMAV FB RH .................................65RVMV FB RH ...................................66RVMAV-K FB RH ..............................68RVMV-K FB RH ................................69RZ ....................................................71RV-K .................................................72RZ1-K (AS) ........................................ 74RZ1-K (AS) Individual by-pass .......... 76RZ1FAZ1 ..........................................77RZ1FZ1 ............................................79RZ1FAZ1-K (AS) ...............................81RZ1FZ1-K (AS) ..................................83RZ1-K mica (AS+) .............................85RZ1FZ1-K mica (AS+) .......................87NYY .................................................89N2XY ...............................................91N2XH ............................................... 93
Instrumentation and controlROZ1-K (AS) 300/500V ....................95ROZ1-K mica (AS+) 300/500V .........96ROZ1FZ1-K mica (AS+) 300/500V ...97LiYCY 300/500V ...............................98YCY / 05VC4V-K 300/500V ............100YSLCY 300/500V ............................102H05VVC4V5-K 300/500V ..............10405Z1C4Z1-K (AS) 300/500V ...........106VC4V-K 0,6/1kV .............................108RC4V-K 0,6/1kV ............................. 110RC4Z1-K (AS) 0,6/1kV .................... 112RC4Z1-K mica (AS+) 0,6/1kV ......... 114RZ1C4Z1-K mica (AS+) 0,6/1kV ..... 116RVKV-K 0,6/1kV ............................. 118RZ1KZ1-K (AS) 0,6/1kV ..................120
Bare copperRigid bare copper ...........................122Flexible bare copper .......................123
Prewired tubeH07V-U ..........................................124H07V-K ..........................................126H07Z1-K (AS) .................................128
Automotive cablesFLRY-B 105º ....................................130
Technical documentationCurvature radii ...............................131Packaging .......................................132
Index
7
www.cablesrct.com
2x0,5 39 4,80 34
2x0,75 26 5,30 42
3x0,5 39 5,05 40
3x0,75 26 5,55 50
4x0,25 78 4,60 27
4x0,5 39 5,55 49
4x0,75 26 6,05 63
5x0,5 39 6,05 59
5x0,75 26 6,65 82
H03VV-F
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/300V Cables
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228.
2. Insulation PVC insulation type TI-2 according to BS7655
3. Sheathing PVC sheath type TM-2 according to BS7655 and HD 21:5S3:1994/A1:1999
Rated Voltage 300/300V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to HD 303S2:2001
·
· PVC with reduced hydrogen chloride (HCL) emission
Applications
· Indoor or receiver installations · Indoor installations in housing · Premises that contain a bath or shower · Installations in premises with special characteristics · Installations with special purposes: provisional and
temporary works installations · Installations with special purposes: fairs and stands · Receiver installations · Electrical installations in furnishings
Description These cables are indicated for mobile indoor installations and to supply household appliances with low mechanical strain.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
8
www.cablesrct.com
H05V-U
1x0,50 36,00 2,00 9
1x0,75 24,50 2,20 11
1x1 18,10 2,40 14
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Technical characteristics1. Conductor Rigid electrolytic copper conductor (Class I) according to BS EN 60228:2005 (previously
BS6360) and EN 60228
2. Insulation PVC insulation type TI-1 according to BS7655 and HD 21.3S3:1995/A2:2008
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
Applications · Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description These cables are indicated for executing permanent protected installations, electrical control panels and signal or control cir-cuits.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
9
www.cablesrct.com
H05V-K
1x0,25 78 1,60 4,60
1x0,35 56 1,70 5,70
1x0,5 39 2,20 8,70
1x0,75 26 2,30 11,00
1x1 19,5 2,40 13,00
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and EN 60228
2. Insulation PVC insulation type TI-1 according to BS7655 and HD 21.3S3:1995/A2:2008
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
Applications · Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description These cables are indicated for executing permanent protected installations, electrical control panels and signal or control circuits.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
10
www.cablesrct.com
105º
Style 1015 22 1x0,5 36,00 2,00 7
Style 1015 20 1x0,75 24,50 2,20 10
Style 1015 18 1x1,00 18,10 2,50 14
Tri-Rated H05V2-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Technical characteristics1. Conductor Electrolytic copper conductor (Class I), according to BS EN 60228:2005 (previously BS6360) and
UNE 60228
2. Insulation PVC insulation type TI-3 according to BS 6231, UL 758, CSA 22.2, UNE 21031-7 and HD 21.7S2:1996/11:1999
Nominal voltage 300/500V; UL 600V; BS 0,6/1kV
Test voltage 2.000V in A.C.
Maximum temperature 105 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
Applications
· Internal or external wiring for electrical or electronic equipment· Installations in premises with special characteristics: premises
at high temperature
Description Used for internal wiring of control equipment, in those places where special high temperature behaviour is required. Its standardisation, HD 21, BS 6231, UL 758 and CSA 22.2, makes it adequate to be marketed all over the world without technical barriers.
Dimensions
Style AWG Section(mm2)
Resistanceat 20 ºC
External diameter
(mm)
Weight(Kg/Km)
11
www.cablesrct.com
105º
Style 1015 24 1x0,25 78,00 1,60 4,50
Style 1015 23 1x0,35 56,00 1,70 5,60
Style 1015 22 1x0,50 39,00 2,50 9,70
Style 1015 20 1x0,75 26,00 2,75 13,00
Style 1015 18 1x1 19,50 2,85 15,00
Tri-Rated H05V2-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation PVC insulation type TI-3 according to BS 6231, UL 758, CSA 22.2, UNE 21031-7 and HD 21.7S2:1996/A1:1999
Nominal voltage 300/500V; UL 600V; BS 0,6/1kV
Test voltage 2.000V in A.C.
Maximum Temperature 105 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
Applications
· Internal or external wiring for electrical or electronic equipment
· Installations in premises with special characteristics: premises at high temperature
Description Used for internal wiring of control equipment, in those places where special high temperature behaviour is required. Its standardisation, HD 21, BS 6231, UL 758 and CSA 22.2, make sit adequate to be marketed all over the world without technical barriers.
Dimensions
Style AWG Section(mm2)
Resistanceat 20 ºC
External diameter
(mm)
Weight(Kg/Km)
12
www.cablesrct.com
H05VV-F
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Description These cables are indicated for indoor mobile installations and household appliances with medium mechanical strain, their main use being for domestic applications.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation PVC insulation, type TI-2, according to BS7655 and HD 21.5S3:1994/A2:2001
3. Sheath PVC sheath, type TM-2, according to BS7655 and HD 21:5S3:1994/A2:2001
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· PVC with reduced hydrogen chloride (HCL) emission
Applications
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
· Installations in premises with special characteristics
· Installations with special purposes
· Provisional and temporary works installations
· Electrical installations in furnishings
13
www.cablesrct.com
7x1 19,50 9,70 1357x1,5 13,30 11,05 1998x0,5 39,00 9,20 1118x0,75 26,00 9,50 1388x1 19,50 10,05 1598x1,5 13,30 11,05 24910x0,5 39,00 10,25 13010x0,75 26,00 10,15 16410x1 19,50 11,85 21112x0,5 39,00 10,45 15012x0,75 26,00 10,85 18912x1 19,50 12,30 23314x0,75 26,00 11,55 21514x1 19,50 13,40 27316x0,5 39,00 10,45 17016x0,75 26,00 12,45 24616x1 19,50 14,60 30519x0,5 39,00 12,75 23719x0,75 26,00 13,10 28319x1 19,50 14,40 35724x0,5 39,00 15,80 25724x0,75 26,00 14,50 34624x1 19,50 17,20 45325x1 19,50 17,20 46130x0,5 39,00 16,30 38230x0,75 26,00 16,30 43430x1 19,50 18,65 55237x0,75 26,00 17,70 52037x1 19,50 20,70 713
2x0,75 26,00 5,85 472x1 19,50 6,05 542x1,5 13,30 7,10 732x2,5 7,98 9,05 1232x4 4,95 10,20 1652x6 3,30 11,50 2023x0,75 26,00 6,35 593x1 19,50 6,50 653x1,5 13,30 7,60 923x2,5 7,98 9,00 1433x4 4,95 10,65 1983x6 3,30 12,70 2884x0,75 26,00 6,90 704x1 19,50 7,85 924x1,5 13,30 8,80 1204x2,5 7,98 10,80 1864x4 4,95 12,50 2634x6 3,30 13,60 3595x0,75 26,00 7,80 885x1 19,50 8,40 1085x1,5 13,30 10,00 1535x2,5 7,98 12,00 2305x4 4,95 13,80 3285x6 3,30 15,35 4426x0,5 39,00 9,00 816x0,75 26,00 8,80 1136x1 19,50 9,05 1227x0,5 39,00 9,00 857x0,75 26,00 8,80 123
H05VV-FCables 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
14
www.cablesrct.com
05VV-F
2x0,50 39,00 5,50 39
3x0,50 39,00 5,80 47
4x0,50 39,00 6,60 60
5x0,50 39,00 7,20 72
2x1 19,50 6,60 68
3G1 19,50 7,00 80
4G1 19,50 7,80 97
5G1 19,50 8,50 127
6G1 19,50 9,50 139
7G1 19,50 10,30 150
8G1 19,50 10,60 182
10G1 19,50 12,07 207
12G1 19,50 12,80 252
14G1 19,50 13,45 298
16G1 19,50 14,60 335
19G1 19,50 15,30 383
24G1 19,50 18,20 490
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Description These cables are indicated for indoor mobile installations and house-hold appliances with medium mechanical strain, their main use being for domestic applications.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation PVC insulation, type TI-2, according to BS7655 and HD 21.5S3:1994/A2:2001
3. Sheath PVC sheath, type TM-2, according to BS7655 and HD 21:5S3:1994/A2:2001
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· PVC with reduced hydrogen chloride (HCL) emission
Applications
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
· Installations in premises with special characteristics
· Installations with special purposes.
· Provisional and temporary works installations
· Electrical installations in furnishings
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
15
www.cablesrct.com
H05VV5-F
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation PVC insulation, type TI-2, according to UNE 21031-13 and HD 21.13S1:1995/A1:2001
3. Sheathing PVC sheath with nitrile rubber additive, type TM-5, oil resistant, according to UNE 21031 and HD 21.13S1:1995/A1:2001
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Mineral oil-resistant cable according to UNE-EN 60811, EN 60811 and IEC 60811
·
·
·
300/500V Cables
Applications
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
· Installations in premises with special characteristics
· Installations with special purposes
· Provisional and temporary works installations
· Electrical installations in furnishings
Description These cables are indicated for indoor use, mobile services, signals and service connection in tool machines. The sheath of these cables has excellent resistance properties to abrasion, humidity, impact as well as to mineral oils for general use.
16
www.cablesrct.com
2x0,5 39 5,55 31
2x0,75 26 5,80 45
2x1 19,5 6,05 53
3x0,5 39 5,80 45
3x0,75 26 6,45 57
3x1 19,5 6,50 65
4x0,5 39 6,95 60
4x0,75 26 7,45 76
4x1 19,5 7,25 81
5x0,5 39 8,40 72
5x0,75 26 8,55 90
5x1 19,5 8,40 104
6x0,5 39 8,05 81
6x0,75 26 8,25 102
6x1 19,5 9,05 122
7x0,75 26 8,40 117
7x1 19,5 9,70 135
8x0,5 39 9,20 111
8x1 19,5 10,05 159
10x0,5 39 9,20 130
10x1 19,5 11,85 211
12x0,5 39 10,95 150
12x0,75 26 11,40 198
12x1 19,5 12,30 233
14x1 19,5 13,40 273
16x0,5 39 10,45 170
16x1 19,5 14,60 305
19x0,5 39 12,75 237
19x0,75 26 14,10 306
19x1 19,5 14,40 357
24x0,5 39 15,80 257
24x1 19,5 17,20 453
25x1 19,5 17,20 461
30x0,5 39 16,30 382
30x0,75 26 17,75 484
30x1 19,5 18,65 552
37x0,75 26 19,30 580
37x1 19,5 20,70 713
H05VV5-F
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Cables available up to 61 conductors.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
300/500V Cables
17
www.cablesrct.com
H05V2V2-F
2x0,75 26,00 5,85 47
2x1 19,50 6,05 54
2x1,5 13,30 7,10 73
2x2,5 7,98 9,05 123
2x4 4,95 10,20 165
3x0,75 26,00 6,35 59
3x1 19,50 6,50 65
3x1,5 13,30 7,60 92
3x2,5 7,98 9,00 143
3x4 4,95 10,65 198
4x0,75 26,00 6,90 70
4x1 19,50 7,85 92
4x1,5 13,30 8,80 120
4x2,5 7,98 10,80 186
4x4 4,95 12,50 263
5x0,75 19,50 7,80 88
5x1 13,30 8,40 108
5x1,5 7,98 10,00 153
5x2,5 4,95 12,00 230
5x4 4,95 13,80 328
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Applications
· Indoor or receiver installations· Indoor installations in housing
· Installations in premises with special characteristics
· Receiver installations
· Electrical installations in furnishings
Description These cables are indicated for mobile indoor installations and to supply household appliances, where special high temperature behaviour is required.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation PVC type TI-3 according to UNE 50363-3
3. Sheathing PVC type TM-3 according to EN 50363-4-1
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to HD 303S2
· PVC with reduced hydrogen chloride (HCL) emission
DimensionsSection(mm2)
Resistanceat 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
300/500V Cables
18
www.cablesrct.com
3x1,5 13,30 9,85 128
3x2,5 7,98 11,70 188
3x4 4,95 13,35 260
3x6 3,30 15,00 346
4x1,5 13,30 10,85 157
4x2,5 7,98 12,85 231
4x4 4,95 14,70 321
4x6 3,30 16,70 434
4x10 1,91 22,15 757
4x16 1,21 25,10 1047
5x1,5 13,30 11,95 189
5x2,5 7,98 14,15 276
5x4 4,95 16,35 392
5x6 3,30 18,55 529
5x10 1,91 24,35 912
5x16 1,21 27,80 1276
Arctic Grade
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Applications
· Installations at very low temperatures (-40 ºC) where the cable
Description These cables are designed to support severe climate conditions
plastic formulation for the Arctic Grade cables, manufactured
in extreme cold conditions, making them ideal for outdoor
temperatures of below 0 ºC.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS 6360 UNE-EN 60228 and UNE 60228
2. Insulation PVC Insulation type Arctic Grade
3. Sheathing Arctic Grade type PVC, blue or yellow
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Min/Max temperature -40 ºC to 70 ºC
Other characteristics
· Sheath colours: blue or yellow
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
DimensionsSection(mm2)
Resistance at 20 ºC
ExternalDiameter
(mm)
Weight(Kg/Km)
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
300/500V Cables
19
www.cablesrct.com
FR-N05 A05VV-U/R
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Applications These cables are suitable for use in domestic installations, housing and similar premises. Mainly to supply household appliances even in the case of heating and kitchens if there is no risk of contact with hot parts.
Description These cables are suitable for use in housing. To supply household appliances even in the case of heating and kitchens if there is no risk of contact with hot parts.
Technical characteristics1. Conductor Electrolytic copper conductor (Class I and II) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation Insulation TM-1 according to 21031-4, HD 21.4S2:1990, IEC 227-4:1979 MOD and NF C32-207/A1
3. Sheathing Sheath TM-1 according to 21031-4, HD 21.4S2:1990, IEC 227-4:1979 MOD and NF C32-207/A1
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
20
www.cablesrct.com
1x1,5 12,10 5,40 44
1x2,5 7,41 6,00 59
1x4 4,61 6,70 80
1x6 3,08 7,20 103
1x10 1,83 8,40 151
1x16 1,15 9,30 213
1x25 0,727 10,95 318
1x35 0,524 12,00 413
2x1,5 12,10 8,20 106
2x2,5 7,41 9,40 146
2x4 4,61 10,70 201
2x6 3,08 12,10 269
2x10 1,83 15,00 420
2x16 1,15 16,90 584
2x25 0,727 20,40 876
2x35 0,524 22,90 1.146
3x1,5 12,10 8,60 123
3x2,5 7,41 9,85 172
3x4 4,61 11,25 242
3x6 3,08 13,15 341
3x10 1,83 15,85 517
3x16 1,15 17,90 731
3x25 0,727 22,05 1.125
3x35 0,524 24,30 1.456
4x1,5 12,10 9,25 146
4x2,5 7,41 10,65 207
4x4 4,61 12,65 306
4x6 3,08 14,30 415
4x10 1,83 17,25 635
4x16 1,15 19,60 907
4x25 0,727 24,15 1.400
4x35 0,524 26,70 1.822
5x1,5 12,10 9,95 170
5x2,5 7,41 11,55 243
5x4 4,61 13,70 361
5x6 3,08 15,55 493
5x10 1,83 18,80 758
5x16 1,15 21,85 1.110
5x25 0,727 26,50 1.685
5x35 0,524 29,35 2.200
FR-N05 A05VV-U/R
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Cables with more than 3 conductors can be manufactured with one of the primaries yellow/green.
21
www.cablesrct.com
1x0,25 78,00 1,60 4,70
1x0,35 52,40 1,70 5,80
1x0,5 39,00 2,15 8,70
1x0,75 26,00 2,25 11,00
1x1 19,50 2,50 13,00
H05Z1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation Thermoplastic halogen-free material insulation, type TI-7, according to HD 21.15S1:2006
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· Low halogen content according to UNE-EN 21031-15 Appendix A and HD 21.15S1:2006
· Low corrosive gas emission according to UNE 21031 Appendix A and HD 21.15S1:2006
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
Applications · Individual by-pass
· Indoor or receiver installations
· Public premises
·
protection is required, even in housing.
Description
permanent installations in public premises and where low fumes
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
22
www.cablesrct.com
90ºmax AS
0,50 36,00 2,00 9
0,75 24,50 2,20 11
1 18,10 2,35 14
ES05Z-U (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Applications
Suitable for the following installations:
· Wiring of panels
· Premises with public attendance
Description These cables are suitable for setting up cable installations for panels, especially when we require low corrosive gas and fume emission and an improved behaviour with temperature.
Technical characteristics1. Conductor Electrolytic copper (Class I) in accordance with UNE-EN 60228 and EN 60228
2. Insulationtype EI-5, in accordance with UNE 21027-9 and HD 22.9S3:2007
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Service temperature -15 ºC to 90 ºC
Oher characteristics
· Colours in accordance with UNE 21027 and HD 22.1S4
·
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gas emission in accordance with UNE 21027-9, HD 22-9S3:2007 and IEC 60754-2
· Low opaque gas emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
· Curvature radius: 4 x external diameter
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
23
www.cablesrct.com
AS
1x0,25 78,00 1,60 4,70
1x0,35 52,40 1,70 5,80
1x0,5 39,00 2,15 8,70
1x0,75 26,00 2,25 11,00
1x1 19,50 2,50 13,00
ES05Z1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Applications
· Individual by-pass
· Indoor or receiver installations
· Public premises
·
is required, even in housing.
Description
permanent installations in public premises and where low
such as hospitals, schools, shopping centres, airports and in
cables are also appropriate for the installation of individual by-
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation Halogen-free thermoplastic material insulation, type TI-7, according to UNE 211002 and HD 21.15S1:2006
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
·
· Low halogen content according to UNE 211002 Appendix A and HD 21.15S1:2006
· Low corrosive gas emission according to UNE 211002 Appendix A and HD 21.15S1:2006
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
24
www.cablesrct.com
90ºmax
0,50 36,00 2,00 9
0,75 24,50 2,20 11
1 18,10 2,35 14
H05Z-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Applications
Suitable for the following installations:
· Wiring of panels
· Premises with public attendance
Description These cables are suitable for setting up cable installations for panels, especially when we require low corrosive gas and fume emission and an improved behaviour with temperature.
Technical characteristics1. Conductor Electrolytic copper (Class I) in accordance to according to BS EN 60228:2005 (previously
BS6360) and EN 60228
2. Insulation5, in accordance with UNE 21027-9 and HD 22.9S3:2007
Nominal voltage 300/500V
Test voltage 2.000V in C.A.
Service temperature -15 ºC to 90 ºC
Other characteristics
· Colours in accordance with UNE 21027 and HD 22.1S4
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gas emission in accordance with UNE 21027-9, HD 22-9S3:2007 and IEC 60754-2
· Low opaque gas emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
· Curvature radius: 4 x external diameter
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
25
www.cablesrct.com
90ºmax AS
1x0,5 39,00 2,10 8
1x0,75 26,00 2,30 11
1x1 19,50 2,50 13
ES05Z-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Applications
Suitable for the following installations:
· Wiring of panels
· Premises with public attendance
Description These cables are suitable for setting up cable installations for panels, especially when we require low corrosive gas and fume emission and an improved behaviour with temperature.
Technical characteristics1. Conductor Electrolytic copper (Class V) in accordance according to BS EN 60228:2005 (previously BS6360)
and EN 60228
2. Insulation5, in accordance with UNE 21027-9 and HD 22.9S3:2007
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Service temperature -15 ºC to 90 ºC
Other characteristics
· Colours in accordance with UNE 21027 and HD 22.1S4
·
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gas emission in accordance with UNE 21027-9, HD 22-9S3:2007 and IEC 60754-2
· Low opaque gas emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
· Curvature radius: 4 x external diameter
26
www.cablesrct.com
90ºmax AS
1x0,5 39,00 2,10 8
1x0,75 26,00 2,30 11
1x1 19,50 2,50 13
H05Z-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Applications
Suitable for the following installations:
· Wiring of panels
· Premises with public attendance
Description These cables are suitable for setting up cable installations for panels, especially when we require low corrosive gas and fume emission and an improved behaviour with temperature.
Technical characteristics1. Conductor Electrolytic copper (Class I) in accordance to BS-EN 60228:2005 according to BS EN
60228:2005 (previously BS6360) and EN 60228
2. Insulation5, in accordance with UNE 21027-9 and HD 22.9S3:2007
Nominal voltage 300/500V
Test voltage 2.000V in C.A.
Service temperature -15 ºC to 90 ºC
Other characteristics
· Colours in accordance with UNE 21027 and HD 22.1S4
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gas emission in accordance with UNE 21027-9, HD 22-9S3:2007 and IEC 60754-2
· Low opaque gas emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
27
www.cablesrct.com
AS
H05Z1Z1-F (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Applications
· Indoor or receiver installations
· Public premises
·
· Installations in premises with special characteristics
· Installations with special purposes: provisional and temporary works installations
· Installations with special purposes, fairs and stands
Description
cables are indicated for indoor mobile installations and for household appliances with medium mechanical strain.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation
3. Sheathing
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.154:2002
·
·
· Low halogen content according to UNE 211002 Appendix A and HD 21.15 S1:2006
· Low corrosive gas emission according to UNE 211002 Appendix A and HD 21.15 S1:2006
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
28
www.cablesrct.comH05Z1Z1-F (AS)
2x0,5 39,00 5,20 54
2x0,75 26,00 5,70 59
2x1 19,50 6,30 57
2x1,5 13,30 7,05 77
2x2,5 7,98 9,10 127
3x0,5 39,00 5,70 62
3x0,75 26,00 6,00 72
3x1 19,50 6,50 68
3x1,5 13,30 7,90 103
3x2,5 7,98 9,50 156
4x0,5 39,00 6,70 63
4x0,75 26,00 6,60 87
4x1 19,5 7,70 91
5x0,5 39,00 6,80 85
5x0,75 26,00 7,40 98
5x1 19,50 8,70 116
5x1,5 13,30 10,00 162
5x2,5 7,98 11,90 241
6x1 19,50 10,05 150
7x1 19,50 9,65 153
8x1 19,50 10,15 166
10x1 19,50 12,30 232
12x1 19,50 12,60 268
14x1 19,50 13,50 306
16x1 19,50 14,25 343
19x1 19,50 14,95 387
24x1 19,50 17,85 532
27x1 19,50 18,20 566
30x1 19,50 19,05 623
37x1 19,50 20,70 745
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
300/500V Cables
29
www.cablesrct.com
AS6G1 19,50 9,70 135
7G1 19,50 10,41 166
8G1 19,50 10,87 185
10G1 19,50 14,03 211
14G1 19,50 13,30 277
16G1 19,50 14,15 315
05Z1Z1-F (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Applications
· Indoor or receiver installations
· Public premises
·
· Installations in premises with special characteristics
· Installations with special purposes: provisional and temporary works installations
· Installations with special purposes, fairs and stands
They are also appropriate for other installations where greater
Description Especially indicated those places where high safety materials
These cables are indicated for indoor mobile installations and household appliances with medium mechanical strain.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and UNE 60228
2. Insulation
3. Sheathing21.14S1:2002
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE-EN 50334 and EN 50334:2001
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
30
www.cablesrct.com
NYM-J / NYM-O
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
Description These cables are suitable for industrial use, household use and wiring. Made in accordance with VDE 0250-204. These cables can be used over and under plaster, masonry and concrete. The cables must not come in direct contact with concrete. Their use in open air is only possible as long as the cable is protected against direct sunlight. They can be used in dry, damp or wet environments.
Applications
· Internal or receptive installations
· Internal installations for houses and premises
· Installations in premises with special characteristics
· Installations with special purposes: building work provisional and temporary installations
· Receiver installations
· Electrical installations on furniture
Technical characteristics1. Conductor Rigid electrolytic copper (Class I and II) in accordance with DIN VDE 0295, according to BS EN
60228:2005 (previously BS6360), EN 60228 and IEC 60228
2. Insulation PVC type TI-1 in accordance with DIN VDE 0281-1, UNE 21031-4, HD 21.4S2:1990 and IEC227-4:1979 MOD
3. Filling PVC
4. Cover PVC type TM-1 in accordance with DIN VDE 0281-1, UNE 21031-4, HD 21.4S2:1990 and IEC227-4:1979 MOD
Nominal voltage 300/500V
Test voltage 2.000V in C.A.
Maximum temperature 70 ºC
Other characteristics
· Made in accordance with VDE 0250-204· Colours in accordance with DIN VDE 0293-308, UNE 21089 and HD 186S2·· PVC with reduced hydrogen chloride (HCL) emission· NYM-J cables are made with a yellow/green conductor· NYM-O cables are made without yellow/green conductor
31
www.cablesrct.com
1x1,5 RE 12,10 5,40 50
1x2,5 RE 7,4 6,00 60
1x4 RE 4,61 6,60 85
1x6 RE 3,08 7,20 105
1x10 RE 1,83 8,50 160
1x16 RM 1,15 9,70 220
2x1,5 RE 12,10 8,80 110
2x2,5 RE 7,41 10,00 155
3x1,5 RE 4,61 8,40 120
3x2,5 RE 3,08 9,60 170
3x4 RE 1,83 11,30 250
3x6 RE 12,10 12,80 335
3x10 RE 1,83 17,00 565
4x1,5 RE 12,10 9,20 150
4x2,5 RE 7,41 10,60 210
4x4 RE 4,61 12,70 315
4x6 RE 3,08 13,80 410
4x10 RE 1,83 17,40 680
4x16 RM 1,15 20,40 970
4x25 RM 0,727 25,20 1.500
4x35 RM 0,524 28,40 2.000
5x1,5 RE 12,10 9,90 175
5x2,5 RE 7,41 11,50 250
5x4 RE 4,61 13,80 370
5x6 RE 3,08 15,00 500
5x10 RE 1,83 19,00 810
5x16 RM 1,15 22,70 1.200
5x25 RM 0,727 27,70 1.800
7x1,5 RE 12,10 11,60 150
7x2,5 RE 7,41 13,70 380
10x1,5 RE 12,10 14,50 365
NYM-J / NYM-O
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
300/500V Cables
RE: 1 single round conductor wire, Class IRM: Multi-conductor round cable, Class II
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
32
www.cablesrct.com
NHXMH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Applications
such as in: hotels, hospitals, theatres, shopping centres…
Description NHXMH energy cables are suitable for installations where spe-
and corrosive gas emission. The insulated wires can lay in, on and under plaster, in dry, humid and wet rooms, in concrete without shake and tamp concrete. These insulated wires can also be installed in earth.
The NHXMH-J cables are UV-retardant, can be laid in ground and meet all requirements of DIN EN VDE 0250-214.
1. Conductor Class I electrolytic copper for cross-sections 1.5 to 10 and class II for cross-sections 16 to 35 in compliance with DIN VDE 0295
2. Insulation Type 2XI1 cross-linked polyethylene (XLPE) in compliance with DIN VDE 0276
3. Casing
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature -15 ºC / 90 ºC
Other characteristics
· Colour of the casing Grey
· Low halogen and corrosive gas content in compliance with DIN VDE 0482 part 267-2-2· Low emission of opaque fumes in compliance with DIN VDE 0482 part 268
300/500V cables
33
www.cablesrct.comNHXMH
1x1,5 12,10 8,01 84,701x2,5 7,41 8,36 98,631x4 4,61 9,00 121,861x6 3,08 9,75 150,661x10 1,83 10,75 201,901x16 1,21 11,60 267,642x1,5 12,10 8,42 102,362x2,5 7,41 9,12 131,002x4 4,61 10,40 180,552x6 3,08 11,90 246,772x10 1,83 14,70 389,642x16 1,21 16,40 538,682x25 0,78 20,10 821,252x35 0,554 24,00 1.158,353x1,5 12,10 8,81 119,603x2,5 7,41 9,56 157,223x4 4,61 10,94 220,803x6 3,08 12,96 317,903x10 1,83 15,52 486,523x16 1,21 17,76 704,313x25 0,78 21,72 1.073,923x35 0,554 25,47 1.484,024x1,5 12,10 9,43 142,484x2,5 7,41 10,28 190,504x4 4,61 12,23 282,414x6 3,08 14,44 405,624x10 1,83 16,86 605,144x16 1,21 19,32 883,374x25 0,78 24,11 1.375,574x35 0,554 27,86 1.874,205x1,5 12,10 10,11 167,425x2,5 7,41 11,05 226,435x4 4,61 13,58 350,085x6 3,08 15,61 486,725x10 1,83 18,31 732,425x16 1,21 21,40 1.094,065x25 0,78 26,26 1.675,315x35 0,554 30,84 2.319,907x1,5 12,10 10,83 204,097x2,5 7,41 12,28 293,19
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
DimensionsSection(mm2)
Resistanceat 20 ºC
ExternalDiameter
(mm)
Weight(Kg/Km)
300/500V cables
34
www.cablesrct.com
1x1,5 12,10 2,65 19
1x2,5 7,41 3,20 29
1x4 4,61 3,80 45
1x6 3,08 4,40 64
1x10 1,83 5,60 106
H07V-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Technical characteristics1. Conductor Electrolytic copper conductor (Class I), according to BS EN 60228:2005 (previously BS 6360)
and EN 60228
2. Insulation PVC insulation, type TI-1, according to BS 7655 and HD 21.3S3:1995/A2:2008
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other chatacteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
Applications
· Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
·
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description These cables are indicated for executing permanent installations
well as domestic and industrial lighting. They are easy to install thanks to their superslide insulation.
35
www.cablesrct.com
1x1,5 12,10 2,95 20
1x2,5 7,41 3,60 33
1x4 4,61 4,05 47
1x6 3,08 4,55 65
1x10 1,83 5,70 108
1x16 1,15 6,65 163
1x25 0,727 8,30 257
1x35 0,524 9,30 346
1x50 0,387 11,10 470
1x70 0,268 13,35 667
1x95 0,193 15,20 924
1x120 0,153 18,50 1172
1x185 0,101 21,95 1810
1x240 0,0775 22,55 2328
H07V-R
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Technical characteristics1. Conductor Electrolytic copper conductor (Class II), according to BS EN 60228:2005 (previously BS6360)
and EN 60228
2. Insultation PVC insulation, type TI-1, according to BS 21031-3 and HD21.3S3:1995/A2:2008
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum Temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
Applications
· Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Indoor installations in housing. Premises that contain a bath or shower
·
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description These cables are indicated for executing permanent installations
well as domestic and industrial lighting. They are easy to install thanks to their superslide insulation.
36
www.cablesrct.com
1x1,5 13,30 2,85 19
1x2,5 7,98 3,50 29
1x4 4,95 3,95 43
1x6 3,30 4,55 61
1x10 1,91 6,05 105
1x16 1,21 6,90 156
1x25 0,78 8,70 238
1x35 0,554 9,95 324
1x50 0,386 11,90 466
1x70 0,272 13,80 661
1x95 0,206 16,50 879
1x120 0,161 17,80 1115
1x150 0,129 19,90 1387
1x185 0,106 22,30 1701
1x240 0,0801 25,00 2174
1x300 0,0641 27,30 2664
1x400 0,0486 31,20 3387
H07V-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and EN 60228
2. Insulation PVC insulation, type TI-1, according to BS 7655 and HD 21.3S3:1995/A2:2008
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
Applications
· Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
·
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description These cables are indicated for executing permanent installations
well as domestic and industrial lighting. They are easy to install
37
www.cablesrct.com
Style 1015 16 1x1,5 12,10 2,80 19
Style 1015 14 1x2,5 7,41 3,35 30
Style 1015 12 1x4 4,61 3,85 44
105º
Tri-Rated H07V2-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Dimensions
Style AWG Section(mm2)
Resistanceat 20 ºC
External diameter
(mm)
Weight(Kg/Km)
Applications
· Internal or external wiring for electrical or electronic equipment· Installations in premises with special characteristics: premises at
high temperature
Description Used for internal wiring of control equipment, in those places where special high temperature behaviour is required. Its standardisation, HD 21, BS 6231, UL 758 y CSA 22.2, makes it suitable to be marketed all over the world without technical barriers.
Technical characteristics
1. Conductor Electrolytic copper conductor (Class I), according to BS EN 60228:2005 (previously BS 6360) and EN 60228.
2. Insulation PVC insulation, type TI-3, according to BS 6231, UL 758 and CSA 22.2, UNE 21031-7 and HD 21.7S2:1996/A1:1999
Rated voltage 450/750V; UL 600V; BS 6231 0,6/1kV
Test voltage 2.500V in A.C.
Maximum temperature 105 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
38
www.cablesrct.com
Style 1015 16 1x1,5 13,30 3,05 20
Style 1015 14 1x2,5 7,98 3,50 29
Style 1015 12 1x4 4,95 4,05 43
Style 1015 10 1x6 3,30 4,60 60
Style 1015 (1028) 8 1x10 1,91 6,30 108
Style 1015 (1283) 6 1x16 1,21 8,25 174
Style 1015 (1283) 4 1x25 0,78 9,35 251
Style 1015 (1283) 2 1x35 0,554 10,60 343
Style 1015 (1284) 1 1x50 0,386 13,30 502
Style 1015 (1284) 2/0 1x70 0,272 14,75 677
Style 1015 (1284) 3/0 1x95 0,206 17,50 906
Style 1015 (1284) 4/0 1x120 0,161 18,65 1128
Style 1015 (1284) 250 MCM 1x150 0,129 20,70 1405
Style 1015 (1284) 350 MCM 1x185 0,106 22,95 1717
Style 1015 (1284) 450 MCM 1x240 0,0801 25,60 2219
105º
Tri-Rated H07V2-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Dimensions
Style AWG Section(mm2)
Resistanceat 20 ºC
External diameter
(mm)
Weight(Kg/Km)
Applications · Internal or external wiring for electrical or electronic equipment· Installations in premises with special characteristics: premises at
high temperature
Description Used for internal wiring of control equipment, in those places where special high temperature behaviour is required. Its standardisation, HD 21, BS 6231, UL 758 y CSA 22.2, makes it suitable to be marketed all over the world without technical barriers.
Technical characteristics
1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS 6360) and EN 60228
2. Insulation PVC insulation, type TI-3, according to BS 6231, UL 758 and CSA 22.2, UNE 21031-7 and HD 21.7S2:1996/A1:1999
Rated voltage 450/750V; UL 600V; BS 6231
Test voltage 2.500V in A.C.
Maximum temperature 105 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
39
www.cablesrct.com
AS
1x1,5 13,30 2,80 19
1x2,5 7,98 3,45 30
1x4 4,95 4,05 42
1x6 3,30 4,60 61
1x10 1,91 5,95 106
1x16 1,21 7,00 156
1x25 0,78 8,70 243
1x35 0,554 9,95 331
1x50 0,386 11,90 474
1x70 0,272 13,80 665
1x95 0,206 16,50 891
1x120 0,161 17,80 1.072
1x150 0,129 19,90 1.347
1x185 0,106 22,30 1.649
1x240 0,0801 25,00 2.154
1x300 0,0641 27,30 2.664
1x400 0,0486 31,20 3.387
H07Z1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Individual by-pass
· Indoor or receiver installations
· Public premises
·
required, even in housing.
Description
permanent installations in public premises and where low fumes
hospitals, schools, shopping centres, airports and all those
cables are also appropriate for the installation of individual by-passes.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and EN 60228
2. Insulation Thermoplastic halogen-free material insulation, type TI-7, according to HD 21.15S1:2006
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gases emission in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low opaque fume emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
40
www.cablesrct.com
90ºmax
1x1,5 12,10 2,80 19
1x2,5 7,41 3,35 30
1x4 4,61 3,85 45
1x6 3,08 4,40 65
H07Z-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Applications
· Meter centralization
· Premises with public attendance
Description These cables are suitable for wiring installations for meter centralization and panels, especially when a low fume and corrosive gases and improved behaviour with temperature are required.
Technical characteristics1. Conductor Electrolytic copper (Class I) according to BS EN 60228:2005 (previously BS 6360) and EN 60228
2. InsulationEI-5 in accordance with UNE 21027-9 and HD 22.9S3:2007
Tensión nominal 300/500V
Tensión de ensayo 2.500V in C.A.
Temperatura de servicio -15 ºC to 90 ºC
Otras características
· Colours in accordance with UNE 21027 and HD 22.1S4
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gases emission in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low opaque fume emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
· Curvature radius: 4 x external diameter
41
www.cablesrct.com
90ºmax
1x1,5 12,10 2,95 20
1x2,5 7,41 3,65 32
1x4 4,61 4,05 45
1x6 3,08 4,55 65
1x10 1,83 5,75 107
1x16 1,15 6,60 161
1x25 0,727 8,30 263
1x35 0,524 9,80 343
1x50 0,387 10,95 464
1x70 0,268 13,00 667
1x95 0,193 15,10 924
H07Z-R
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Description These cables are indicated for executing wiring installations for board, panels, and especially when low fume and corrosive gas emission, and improved temperature behaviour are required.
Technical characteristics1. Conductor Electrolytic copper conductor (Class II), according to BS EN 60228:2005 (previously BS 6360)
and EN 60228
2. Insulationsion, type EI-5, according to UNE 21027-9 and HD 22.9S3:2007
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21027 and HD 22.1S4
·
· Low halogen content according to UNE 21027-9 and HD 22.9S3:2007
· Low corrosive gas emission according to UNE 21027-9 and HD 22.9S3:2007
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Applications
· Meter centralization
· Premises with public attendance
42
www.cablesrct.com
90ºmax
1x1,5 13,30 2,90 18
1x2,5 7,98 3,55 29
1x4 4,95 4,05 42
1x6 3,3 4,60 60
1x10 1,91 5,95 101
1x16 1,21 7,00 153
1x25 0,780 8,65 235
1x35 0,554 9,70 320
1x50 0,386 11,60 457
1x70 0,272 13,30 635
1x95 0,206 15,15 841
1x120 0,161 16,80 1.059
1x150 0,129 18,85 1.325
1x185 0,106 21,00 1.624
1x240 0,0801 23,90 2.128
H07Z-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Meter centralization
· Premises with public attendance
Description These cables are suitable for setting up wiring installations for panels, especially when a low fume and corrosive gas emission and improved behaviour with temperature is required.
Technical characteristics1. Conductor Electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS 6360) and EN 60228
2. InsulationEI-5 in accordance with UNE 21027-9 and HD 22.9S3:2007
Nominal voltage 450/750V
Test voltage 2.500V in C.A.
Service temperature -15 ºC to 90 ºC
Other characteristics
· Colours in accordance with UNE 21027 and HD 22.1S4
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gases emission in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low opaque fume emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
· Curvature radius up to 16mm2: 4 x external diameter
· Curvature radius from 25mm2 to 35mm2: 5 x external diameter
· Curvature radius from 50mm2 on: 6 x external diameter
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
43
www.cablesrct.com
90ºmax AS
1x1,5 12,10 2,80 19
1x2,5 7,41 3,35 30
1x4 4,61 3,85 45
1x6 3,08 4,40 65
ES07Z-U (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Meter centralization
· Premises with public attendance
Description These cables are suitable for setting up wiring installations on panels, especially when a low fume and corrosive gas emission and improved behaviour with temperature is required.
Technical characteristics1. Conductor Electrolytic copper (Class I) according to BS EN 60228:2005 (previously BS 6360) and EN 60228
2. InsulationEI-5 in accordance with UNE 21027-9 and HD 22.9S3:20077
Nominal voltage 450/750V
Test voltage 2.500V in C.A.
Service temperature -15 ºC to 90 ºC
Other characteristics
· Colours in accordance with UNE 21027 and HD 22.1S4
·
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gases emission in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low opaque fume emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
· Curvature radius: 4 x external diameter
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
44
www.cablesrct.com
90ºmax AS
1x1,5 12,10 2,95 20
1x2,5 7,41 3,65 32
1x4 4,61 4,05 45
1x6 3,08 4,55 65
1x10 1,83 5,75 107
1x16 1,15 6,60 161
1x25 0,727 8,30 263
1x35 0,524 9,80 343
1x50 0,387 10,95 464
1x70 0,268 13,00 667
1x95 0,193 15,10 924
ES07Z-R (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Board, panels
· Public premises
Description These cables are indicated for executing wiring installations for boards, panels and especially when low fumes and corrosive gas emission, as well as improved temperature behaviour are required.
Technical characteristics1. Conductor Electrolytic copper conductor (Class II), according to BS EN 60228:2005 (previously BS 6360)
and EN 60228
2. Insulationsion, type EI-5, according to UNE 21027-9 and HD 222007
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21027 and HD 22.1S4
·
·
· Low halogen content according to UNE 21027-9 and HD 22.9S3:2007
· Low corrosive gas emission according to UNE 21027-9 and HD 22.9S3:2007
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
45
www.cablesrct.com
90ºmax AS
1x1,5 13,30 2,90 18
1x2,5 7,98 3,55 29
1x4 4,95 4,05 42
1x6 3,3 4,60 60
1x10 1,91 5,95 101
1x16 1,21 7,00 153
1x25 0,780 8,65 235
1x35 0,554 9,70 320
1x50 0,386 11,60 457
1x70 0,272 13,30 635
1x95 0,206 15,15 841
1x120 0,161 16,80 1.059
1x150 0,129 18,85 1.325
1x185 0,106 21,00 1.624
1x240 0,0801 23,90 2.128
ES07Z-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Meter centralization
· Premises with public attendance
Description These cables are suitable for setting up wiring installations on panels, especially when a low fume and corrosive gas emission and improved behaviour with temperature is required.
Technical characteristics1. Conductor Electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS 6360) and EN 60228
2. InsulationEI-5 in accordance with UNE 21027-9 and HD 22.9S3:2007
Nominal voltage 450/750V
Test voltage 2.500V in C.A.
Service temperature -15 ºC to 90 ºC
Other characteristics
· Colours in accordance with UNE 21027 and HD 22.1S4
·
·
· Low halogen content in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low corrosive gases emission in accordance with UNE 21027-9, HD 22.9S3:2007 and IEC 60754-2
· Low opaque fume emission in accordance with UNE-EN 61034, EN 61034 and IEC 61034
· Curvature radius up to 16mm2: 4 x external diameter
· Curvature radius from 25mm2 to 35mm2: 5 x external diameter
· Curvature radius from 50mm2 on: 6 x external diameter
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
46
www.cablesrct.com
2x1,5 12,10 5,50 37
3x1,5 12,10 5,65 56
3x2,5 7,41 7,35 88
3x6 3,08 9,40 191
4x1,5 12,10 6,65 75
5x1,5 12,10 7,45 94
TRIPLÍN® H07V-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing.
Premises that contain a bath or shower
·
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description These cables are indicated for executing permanent installations
well as domestic and industrial lighting. The use of this product range facilitates the installation, reducing execution times and costs.
This product is manufactured according to the utility model (patent) no 200702014, property of Cables RCT.
Technical characteristics1. Conductor Electrolytic copper conductor (Class I) according to BS EN 60228:2005 (previously BS 6360) and
EN 60228
2. Insulation PVC insulation, type TI-1, according to UNE 21031-3 and HD21.S2:1995/A2:2008
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
47
www.cablesrct.com
2x1,5 13,30 5,75 38
2x2,5 7,98 7,00 58
2x6 3,30 8,00 122
2x10 1,91 12,00 212
2x16 1,21 13,00 314
3x1,5 13,30 6,20 56
3x2,5 7,98 7,35 88
3x4 4,95 10,00 129
3x6 3,30 12,00 182
3x16 1,21 16,00 472
4x1,5 13,30 8,20 75
4x2,5 7,98 8,50 117
4x4 4,95 14,00 172
4x16 1,21 18,00 629
5x1,5 13,30 10,25 94
5x2,5 7,98 9,50 146
TRIPLÍN® H07V-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
·
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description These cables are indicated for executing permanent installations
well as domestic and industrial lighting. The use of this product range facilitates the installation, reducing execution times and costs.
This product is manufactured according to the utility model (patent) nº 200702014, property of Cables RCT.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS6360) and EN 60228
2. Insulation PVC insulation, type TI-1, according to UNE 21031-3 and HD21.S2:1995/A2:2008
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
48
www.cablesrct.com
2x1,5 13,30 5,92 37
2x2,5 7,98 7,20 58
3x1,5 13,30 6,26 56
3x2,5 7,98 7,78 90
4x1,5 13,30 8,45 74
4x2,5 7,98 10,14 116
5x1,5 13,30 10,60 92
5x2,5 7,98 12,75 145
TRIPLÍN® H07Z1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Individual derivation
· Indoor and reception facilities
· Public premises
·
Suitable for installations that require increased protection from
Description
installations in places of public competition and where in case of
as hospitals, schools, malls, airports, and in all facilities in which
range easy to install, reducing time and cost of implementation. Available in various color combinations.
This product is manufactured according to the utility model (patent) no 200702014, property of Cables RCT.
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS 6360) and
EN 60228
2. Insulation Halogen-free thermoplastic material such as UNE TI-7 and 211.002 HD 21.15S1:2006
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colors from 21.031 UNE and HD 21.1S4:2002
·
· Fire-retardant according to UNE-EN 50266 and EN 50266
· Halogen low as 211.002 UNE Annex A and HD 21.15S1:2006
· Low corrosive gas emission according to UNE 211.002 Annex A and HD 21.15S1:2006
· Low opaque smoke emission opaque according to UNE-EN 61034, EN 61034 and IEC 6103
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
49
www.cablesrct.com
AS
2x1,5 13,30 5,75 37
2x2,5 7,98 7,00 59
3x1,5 13,30 6,15 56
3x2,5 7,98 7,35 89
4x1,5 13,30 8,20 74
5x1,5 13,30 10,25 93
3x4 4,95 10,00 127
3x6 3,30 13,75 183
3x10 1,91 18,00 319
3x16 1,21 20,30 469
3x25 0,78 18,60 729
3x35 0,554 21,10 993
3x50 0,386 25,30 1.422
5x6 3,30 14,55 304
5x10 1,91 17,50 531
5x16 1,21 19,95 781
5x25 0,78 24,70 1.215
5x35 0,554 26,50 1.655
Triplex H07Z1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
450/750V Cables
Applications
· Individual by-pass
Description These cables are indicated for executing individual by-passes,
conductors plus the tracer wire, red 1,5 section conductor. The aim of this product is to facilitate the installation, reducing the time spent on handling each of the conductors individually.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS
6360) and EN 60228
2. Insulation Thermoplastic halogen-free insulation, type TI-7, according to UNE 21100221 2006 and HD 21.15S1:2006
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteritics
· Colours according to UNE 21031 and HD 21.1S4:2002··· Low halogen content according to UNE 211002 Appendix A and HD 21.15S1:2006· Low corrosive gas emission according to UNE 211002 Appendix A and HD 21.15S1:2006· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
50
www.cablesrct.com
VV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications · Outdoor lighting installations
· Indoor or receiver installations
Description These cables are indicated for industrial connections, control of solenoid valves, machine start-up, robots and internal distribution installations. It can be used in underground networks and permanent installations. The special construction of these cables affords
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation PVC insulation, type A, according to UNE 21123 and IEC 60502-1
3. Sheathing PVC sheath, type ST-1, according to UNE 21123 and IEC 60502-1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
·
·
·
· PVC insulation and sheath with reduced hydrogen chloride (HCL) emission
51
www.cablesrct.com
7x2,5 7,98 13,55 3507x4 4,95 16,5 4507x6 3,3 17,8 6508x1,5 13,3 12,95 3008x2,5 7,98 14,65 40010x1,5 13,3 13,95 35010x2,5 7,98 16,8 55010x4 4,95 21,9 75012x1,5 13,3 15,35 40012x2,5 7,98 17,8 55014x1,5 13,3 16,6 45014x2,5 7,98 18,2 60016x1,5 13,3 17,3 50016x2,5 7,98 19,95 70018x1,5 13,3 17,4 50019x1,5 13,3 18,15 55019x2,5 7,98 21,3 80024x1,5 13,3 20,65 65024x2,5 7,98 22 90027x1,5 13,3 22,05 75030x1,5 13,3 22,6 85030x2,5 7,98 26,35 125037x1,5 13,3 24,6 100037x2,5 7,98 26,8 135040x1,5 13,3 25 105040x2,5 7,98 27,9 145044x1,5 13,3 25,95 115044x2,5 7,98 28,95 160048x1,5 13,3 26,9 120048x2,5 7,98 30,05 170052x1,5 13,3 27,85 130052x2,5 7,98 31,1 185056x1,5 13,3 28,8 140056x2,5 7,98 32,2 195061x1,5 13,3 30,15 155061x2,5 7,98 33,25 2150
1x1,5 13,30 4,95 501x2,5 7,98 5,40 501x4 4,95 6,30 1001x6 3,30 6,85 1001x10 1,91 7,85 1501x16 1,21 8,75 2001x25 0,78 10,45 3001x35 0,554 11,15 4001x50 0,386 13,45 5501x70 0,272 15,30 7001x95 0,206 19,00 9501x120 0,161 20,50 11501x150 0,129 22,90 14501x185 0,106 25,15 17501x240 0,0801 28,10 23001x300 0,0641 29,45 28502x1,5 13,30 8,75 1003x1,5 13,30 9,30 1503x2,5 7,98 10,05 2003x4 4,95 12,70 3003x6 3,30 12,70 3004x1,5 13,30 10,05 1504x2,5 7,98 11,20 2004x4 4,95 11,70 3004x6 3,30 13,85 4004x10 1,91 0 6504x35 0,554 24,6 16505x1,5 13,30 10,95 2005x2,5 7,98 0 2505x4 4,95 0 4005x6 3,30 15,15 4505x16 1,21 0 9506x1,5 13,30 12,25 2506x2,5 7,98 13,6 3006x6 3,30 17,4 6007x1,5 13,30 12 250
VV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
52
www.cablesrct.com
90ºmax
RV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Underground supply networks for outdoor lighting installations
· Electricity distribution networks. Underground service connections
· Indoor or receiver installations
· Installations in premises with special characteristics
Description These cables are indicated for the transport and distribution of low voltage electricity. Recommended for industrial connections, ser-vice connections, internal distribution and outdoor connections. It can be used in underground networks and permanent installations.
Technical characteristics1. Conductor Electrolytic copper conductor (Class I and II), according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation(XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheathing PVC sheath, type DMV-18 according to UNE 21123 and HD 603S1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC sheath with reduced hydrogen chloride (HCL) emission
53
www.cablesrct.com
1x1,5 12,10 5,70 50
1x2,5 7,41 6,12 60
1x4 4,61 6,65 75
1x6 3,08 7,20 95
1x10 1,83 8,15 140
1x16 1,15 9,15 195
1x25 0,727 10,80 290
1x35 0,524 11,90 380
1x50 0,387 13,50 520
1x70 0,268 15,60 720
1x95 0,193 17,35 930
1x120 0,153 19,40 1.175
1x150 0,124 21,40 1.455
1x185 0,0991 23,30 1.745
1x240 0,0754 26,60 2.315
1x300 0,0601 30,20 2.895
1x400 0,0470 34,80 3.935
2x1,5 12,10 8,55 100
2x2,5 7,41 9,39 130
2x4 4,61 10,45 175
2x6 3,08 11,55 225
2x10 1,83 13,45 335
2x16 1,15 15,45 475
2x25 0,727 18,75 710
3x1,5 12,10 9,01 115
3x2,5 7,41 9,92 155
3x4 4,61 11,07 210
3x6 3,08 12,25 275
3x10 1,83 13,82 420
3x16 1,15 16,47 621
3x25 0,727 20,03 915
3x35 0,524 22,66 1.240
4x1,5 12,10 9,92 140
4x2,5 7,41 10,93 190
4x4 4,61 12,22 255
4x6 3,08 13,55 345
4x10 1,83 15,85 535
4x16 1,15 18,27 775
4x25 0,727 22,36 1.175
4x35 0,524 25,07 1.580
4x70 0,268 32,00 2.905
4x95 0,193 35,60 3.755
4x50 0,387 29,21 2.205
5G1,5 12,10 10,79 170
5G2,5 7,41 11,93 230
5G4 4,61 13,37 315
5G6 3,08 14,87 425
5G10 1,83 17,45 655
5G16 1,15 20,17 945
5G25 0,727 24,80 1.450
5G35 0,524 27,40 1.960
5G50 0,387 33,50 2.885
RV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
54
www.cablesrct.com
90ºmax
R2V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Underground supply networks for outdoor lighting installations electricity distribution networks. Underground service connections
· Indoor or receiver installations
· Installations in premises with special characteristics
Description These cables are indicated for the transport and distribution of low voltage electricity. Recommended for industrial connec-tions, service connections, internal distribution and outdoor connections. It can be used in underground networks and per-manent installations.
Technical characteristics1. Conductor Electrolytic copper conductor (Class I and II), according to IEC 60228, BS EN 60228:2005 (pre-
viously BS 6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to HD603S1 and UNE 21123
3. Sheathing PVC sheath, type DMV-18, according to HD 603S1 and UNE 21123
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 308S3:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC with low hydrogen chloride (HCL) emission
55
www.cablesrct.com
1x1,5 12,10 5,70 42
1x2,5 7,41 6,05 51
1x4 4,61 6,70 71
1x6 3,08 7,10 95
1x10 1,83 7,75 135
1x16 1,15 9,10 199
1x25 0,727 10,95 301
1x35 0,524 12,20 391
1x50 0,387 13,50 554
1x70 0,268 15,80 723
1x95 0,193 17,75 1.037
1x120 0,153 20,00 1.228
1x150 0,124 22,90 1.485
1x185 0,101 24,20 18.73
1x240 0,0775 27,20 2.460
1x300 0,062 29,60 3.001
1x400 0,0465 33,90 3.980
1x500 0,03666 38,20 4.774
1x630 0,0283 40,20 6.246
2x1,5 12,10 8,80 101
2x2,5 7,41 9,65 133
2x4 4,61 10,60 158
2x6 3,08 11,60 225
2x10 1,83 13,10 322
2x16 1,15 18,20 582
2x25 0,727 21,95 864
2x35 0,524 24,10 1.089
2x50 0,387 27,25 1.443
2x70 0,268 29,20 1.878
3x1,5 12,10 9,25 121
3x2,5 7,41 10,05 155
3x4 4,61 11,15 207
3x6 3,08 12,30 280
3x10 1,83 14,05 407
3x16 1,15 19,30 725
3x25 0,727 23,00 985
3x35 0,554 25,50 1.333
3x50 0,387 28,70 1.748
3x70 0,268 33,90 2.519
3x95 0,193 38,50 3.388
3x120 0,153 41,00 4.246
3x150 0,124 47,00 5.203
3x185 0,101 52,00 6.577
R2V
4x1,5 12,10 9,95 136
4x2,5 7,41 10,65 172
4x4 4,61 12,15 260
4x6 3,08 13,45 341
4x10 1,83 15,50 471
4x16 1,15 20,85 893
4x25 0,727 24,50 1.269
4x35 0,524 28,55 1.847
4x50 0,387 31,00 2.308
4x70 0,268 37,70 3.332
4x95 0,193 39,00 4.369
4x120 0,153 43,50 5.335
4x150 0,124 48,80 6.664
4x185 0,101 54,00 8.310
4x240 0,0775 61,40 10.868
5x1,5 12,10 10,65 163
5x2,5 7,41 11,65 219
5x4 4,61 13,05 308
5x6 3,08 14,70 414
5x10 1,83 17,70 654
5x16 1,15 23,10 1.104
5x25 0,727 28,00 1.666
5x35 0,524 30,25 2.171
5x50 0,387 37,60 3.299
5x70 0,268 40,00 4.008
5x95 0,193 44,00 5.465
5x120 0,153 50,60 6.855
5x150 0,124 58,35 8.307
5x185 0,101 64,40 10.639
7x1,5 12,10 11,75 210
7x2,5 7,41 12,60 282
7x4 4,61 14,00 379
8x1,5 12,10 13,25 255
10x1,5 12,10 15,00 315
10x1,5 12,10 15,40 352
12x1,5 12,10 14,75 301
12x2,5 7,41 16,15 482
19x1,5 12,10 17,30 472
19x2,5 7,41 21,30 688
24x1,5 12,10 22,00 645
27x1,5 12,10 22,00 702
37x1,5 12,10 23,15 872
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
56
www.cablesrct.com
VVFV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications · Outdoor lighting installations
· Indoor or receiver installations
Description
makes handling and installation easier; they are indicated for transport and distribution of low voltage electricity. Their use is recom-
mended for industrial connections, service connections, internal distribution and outdoor connections. They can be used in under-
ground networks and permanent installations
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation PVC insulation, type A, according to UNE 21123 and IEC 60502-1
3. Armour Bedding PVC
4. Armour Double steel tape armour
5. Sheathing PVC Sheath type ST-1 according to UNE 21123 and IEC 60502
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
·
·
·
· PVC insulation and sheath with reduced hydrogen chloride (HCL) emission
57
www.cablesrct.com
4G1,5 13,30 11,97 195,854G2,5 7,98 12,94 246,694G4 4,95 14,31 323,764G6 3,30 15,64 415,304G10 1,91 17,81 602,094G16 1,21 20,35 850,354G25 0,780 24,33 1.250,074G35 0,554 27,23 1.664,224G50 0,386 31,26 2.295,354G70 0,272 37,75 3.312,414G95 0,206 42,63 4.275,974G120 0,161 48,08 5.449,454G150 0,129 52,71 6.683,954G185 0,106 58,29 8.103,334G240 0,0801 65,81 10.655,975G1,5 13,30 11,94 198,195G2,5 7,98 13,02 257,085G4 4,95 14,56 346,565G6 3,30 16,05 454,125G10 1,91 18,48 675,855G16 1,21 21,31 971,635G25 0,780 25,77 1.446,645G35 0,554 29,18 1.956,845G50 0,386 33,84 2.731,485G70 0,272 39,55 3.814,795G95 0,206 45,32 4.996,415G120 0,161 51,21 6.377,465G150 0,129 56,57 7.886,995G185 0,106 62,73 9.578,79
2x1,5 13,30 10,06 134,392x2,5 7,98 10,86 165,812x4 4,95 12,00 213,702x6 3,30 13,10 269,392x10 1,91 14,90 380,932x16 1,21 17,00 529,222x25 0,780 20,30 773,552x35 0,554 22,70 1.017,962x50 0,386 25,90 1.383,502x70 0,272 30,17 1.918,322x95 0,206 34,24 2.487,712x120 0,161 38,51 3.160,722x150 0,129 42,28 3.873,002x185 0,106 46,92 4.720,722x240 0,0801 53,06 6.193,583G1,5 13,30 10,47 150,903G2,5 7,98 11,34 190,363G4 4,95 12,56 250,343G6 3,30 13,75 321,403G10 1,91 15,69 466,103G16 1,21 17,95 658,713G25 0,780 21,51 970,853G35 0,554 24,09 1.292,173G50 0,386 27,54 1.772,583G70 0,272 32,30 2.482,983G95 0,206 36,67 3.224,293G120 0,161 41,26 4.100,343G150 0,129 45,46 5.055,163G185 0,106 50,62 6.171,463G240 0,0801 57,37 8.143,60
VVFV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
58
www.cablesrct.com
90ºmax
1x4 4,61 11,90 193
1x6 3,08 12,30 222
1x10 1,83 12,95 271
1x16 1,15 14,30 354
1x25 0,727 16,15 482
1x35 0,524 17,40 589
1x50 0,387 18,70 770
1x70 0,268 21,20 981
1x95 0,193 23,15 1.323
1x120 0,153 25,60 1.559
1x150 0,124 28,50 1.858
1x185 0,101 30,20 2.295
1x240 0,0775 33,20 2.929
1x300 0,062 36,00 3.577
1x400 0,0465 40,30 4.681
1x630 0,0283 47,00 7.010
RVFAV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
· Installations in premises with special characteristics
Description These cables are indicated for the transport and distribution of low voltage electricity. Their use is recommended for industrial connections, service connections, internal distribution and outdoor connections. They can be used in underground networks and permanent installations.
The metal armour provides greater protection against mechanical aggressions and the action of rodents.
Technical characteristics1. Conductor Electrolytic copper (Class II), according to BS EN 60228:2005 (previously BS 6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Double aluminium tape armour
5. Sheathing PVC type DMV-18 according to UNE 2113 and HD 603S1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC with low hydrogen chloride (HCL) emission
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
59
www.cablesrct.com
90ºmax
RVFV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
· Installations in premises with special characteristics
Description Manufactured with steel armour, which provides high protection against rodents and mechanical damage, they are indicated for the transport and distribution of low voltage electricity. Their use is recommended for industrial connections, service connections, internal distribution and outdoor connections. It can be used in underground networks and permanent installations.
Technical characteristics1. Conductor Electrolytic copper (Class I and II), according to BS EN 60228:2005 (previously BS 6360) and
UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Double steel armour
5. Sheathing PVC sheath type DMV-18, according to UNE 21123 and HD 603S1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC with low hydrogen chloride (HCL) emission
60
www.cablesrct.com
2x1,5 12,10 12,80 251
2x2,5 7,41 13,65 295
2x4 4,61 14,60 335
2x6 3,08 15,60 417
2x10 1,83 17,30 544
2x16 1,15 20,20 849
2x25 0,727 24,90 1.211
2x35 0,524 28,50 1.493
2x50 0,387 32,05 1.928
2x70 0,268 34,00 2.396
3x1,5 12,10 13,25 277
3x2,5 7,41 14,05 323
3x4 4,61 15,15 392
3x6 3,08 16,30 482
3x10 1,83 18,25 643
3x16 1,15 23,50 1.042
3x25 0,727 27,40 1.371
3x35 0,524 29,90 1.760
3x50 0,387 33,50 2.258
3x70 0,268 38,70 3.116
4x1,5 12,10 13,95 303
4x2,5 7,41 14,65 350
4x4 4,61 16,15 460
4x6 3,08 17,45 560
4x10 1,83 19,70 730
4x16 1,15 25,05 1.234
4x25 0,727 28,90 1.678
4x35 0,524 32,95 2.322
4x50 0,387 35,80 2.856
4x70 0,268 43,70 4.417
5x1,5 12,10 14,65 341
5x2,5 7,41 15,65 410
5x4 4,61 17,05 521
5x6 3,08 18,90 660
5x10 1,83 21,90 946
5x16 1,15 27,50 1.493
5x25 0,727 32,40 2.129
5x35 0,524 35,05 2.705
5x50 0,387 42,40 3.958
7x1,5 12,10 15,75 405
7x2,5 7,41 16,60 488
10x1,5 12,10 19,20 567
RVFV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Cables 0,6/1kV
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
61
www.cablesrct.com
90ºmax
1x6 3,08 11,43 215
1x10 1,83 12,30 260
1x16 1,15 13,20 325
1x25 0,727 14,70 440
1x35 0,524 15,75 545
1x50 0,387 17,05 685
1x70 0,268 18,80 905
1x95 0,193 20,67 1.180
1x120 0,153 22,55 1.450
1x150 0,124 24,64 1.740
1x185 0,0991 26,26 2.115
1x240 0,0754 28,91 2.695
1x300 0,0601 31,51 3.310
1x400 0,0470 34,92 4.185
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
· Installations in premises with special characteristics
Description These cables are indicated for the transport and distribution of low voltage electricity.
Their use is recommended for industrial connections, service connections, internal distribution and outdoor connections. They can be used in underground networks and permanent installations.
The metal armour provides greater protection against mechanical aggressions and the action of rodents.
Technical characteristics1. Conductor Electrolytic copper (Class II), according to BS EN 60228:2005 (previously BS 6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Stainless steel
5. Sheathing PVC type DMV-18 according to UNE 2113 and HD 603S1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC with reduced hydrogen chloride (HCL) emission
RVFV Stainless Steel
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
62
www.cablesrct.com
90ºmax
1x4 4,95 10,90 169
1x6 3,30 11,45 196
1x10 1,91 12,35 248
1x16 1,21 13,40 316
1x25 0,78 15,05 423
1x35 0,5554 16,25 530
1x50 0,386 17,85 688
1x70 0,272 19,90 908
1x95 0,206 21,85 1.136
1x120 0,161 23,90 1.402
1x150 0,129 25,70 1.685
1x185 0,106 27,85 2.003
1x240 0,0801 30,95 2.593
1x300 0,0641 33,10 3.119
1x400 0,0486 36,50 3.847
RVFAV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
· Installations in premises with special characteristics
Description These cables are indicated for the transport and distribution of low voltage electricity. Their use is recommended for industrial connections, service connections, internal distribution and outdoor connections. It can be used in underground networks and permanent installations.
The metal armour provides higher protection against mechanical aggressions and the action of rodents.
Technical characteristics
1. ConductorFlexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS 6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation(XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Double aluminium tape armour
5. Sheathing PVC sheath, type, DMV-18 according to UNE 21123 and HD 603S1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC with reduced hydrogen chloride (HCL) emission
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
63
www.cablesrct.com
90ºmax
RVFV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
· Installations in premises with special characteristics
Description
makes handling and installation easier; they are indicated for transport and distribution of low voltage electricity. Their use is recom-mended for industrial connections, service connections, internal distribution and outdoor connections. They can be used in under-ground networks and permanent installations.
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS 6360) and
UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Double steel tape armour
5. Sheathing PVC sheath type DMV-18 according to UNE 21123 and HD 603S1
Rated voltage 0,6/1kV
Test volatge 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC with reduced hydrogen chloride (HCL) emission
64
www.cablesrct.com
2x1,5 13,30 11,45 211
2x2,5 7,98 12,25 249
2x4 4,95 13,75 318
2x6 3,30 15,00 391
2x10 1,91 17,00 528
2x16 1,21 19,30 706
2x25 0,78 22,95 1.015
2x35 0,5554 24,05 1.202
2x50 0,386 27,25 1.595
3x1,5 13,30 11,85 231
3x2,5 7,98 12,70 277
3x4 4,95 14,30 360
3x6 3,30 15,65 449
3x10 1,91 17,80 621
3x16 1,21 20,25 846
3x25 0,78 22,90 1.145
3x35 0,5554 25,45 1.488
3x50 0,386 29,10 2.011
3x70 0,272 33,70 2.750
4x1,5 13,30 12,55 259
4x2,5 7,98 13,50 317
4x4 4,95 14,90 403
4x6 3,30 16,20 503
4x10 1,91 18,40 704
4x16 1,21 20,90 970
4x25 0,78 24,90 1.396
4x35 0,5554 27,80 1.829
4x50 0,386 32,05 2.501
4x70 0,272 38,35 3.806
5x1,5 13,30 13,30 290
5x2,5 7,98 14,40 359
5x4 4,95 15,95 461
5x6 3,30 17,40 581
5x10 1,91 19,85 824
5x16 1,21 22,70 1.144
5x25 0,78 27,15 1.657
5x35 0,5554 30,55 2.197
5x50 0,386 35,25 3.012
5x95 0,206 48,00 5.855
RVFV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
65
www.cablesrct.com
90ºmax
1x16 1,15 13,80 344
1x25 0,727 16,55 515
1x35 0,524 17,80 626
1x50 0,387 19,10 812
1x70 0,268 22,10 1.066
1x95 0,193 24,05 1.418
1x120 0,153 26,30 1.651
1x150 0,124 29,20 1.964
1x185 0,101 30,50 2.377
1x240 0,0775 34,50 3.127
1x300 0,062 37,10 3.774
1x400 0,0465 41,80 4.945
RVMAV FB RH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Description RVMAV FB RH cables, manufactured with a crown shaped aluminium wire armour, which provides a huge protection against rodents and mechanical damages, are indicated for transporting and distributing low voltage power. It is recommended for industrial connections, service connections, internal distribution and outdoor connections and especially in premises with a high
Technical characteristics
1. Conductor Rigid electrolytic copper (Class I or II) according to UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Crown shaped aluminium wire
5. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colors according to UNE 21089 and HD 308S2
·
· Flame retardant according to UNE-EN 60332, EN 60332 and IEC 60332
· Hydrocarbons resistant according to UIC 895 OR
· PVC with reduced hydrogen chloride (HCL) emission
· Cross-linked polyethylene (XLPE) admits a higher current density than a PVC isolation with the same section
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
·
· Installations in premises with special characteristics
66
www.cablesrct.com
90ºmax
RVMV FB RH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
·
· Installations in premises with special characteristics
Description
RVMV FB RH cables, manufactured with a crown shaped steel wire armour, which provides a huge protection against rodents and mechanical damages, are indicated for transporting and distributing low voltage power. It is recommended for industrial connections,
Technical characteristics1. Conductor Rigid electrolytic copper (Class I or II) according to UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Crown shaped galvanized steel wire
5. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colors according to UNE 21089 and HD 308S2
·
· Flame retardant according to UNE-EN 60332, EN 60332 and IEC 60332
· Hydrocarbons resistant according to UIC 895 OR
· PVC with reduced hydrogen chloride (HCL) emission
· Cross-linked polyethylene (XLPE) admits a higher current density than a PVC isolation with the same section
67
www.cablesrct.com
2x2,5 7,41 14,35 396
2x4 4,61 16,20 559
2x6 3,08 17,20 661
2x10 1,83 18,70 809
2x16 1,15 24,50 1.390
3x1,5 12,10 12,35 304
3x2,5 7,41 13,15 360
3x4 4,61 16,75 628
3x6 3,08 17,90 739
3x10 1,83 19,90 938
4x1,5 12,10 13,05 340
4x2,5 7,41 13,90 405
4x4 4,61 17,75 715
4x6 3,08 19,05 839
4x10 1,83 21,80 1.167
4x16 1,15 25,50 1.742
4x25 0,727 30,80 2.336
5x1,5 12,10 16,25 567
5x2,5 7,41 17,25 655
5x4 4,61 18,65 793
5x6 3,08 20,30 955
5x10 1,83 24,00 1.441
5x16 1,15 29,40 2.115
5x25 0,727 35,30 3.149
RVMV FB RH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Cables 0,6/1kV
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
68
www.cablesrct.com
90ºmax
1x16 1,21 13,20 307
1x25 0,78 15,95 464
1x35 0,554 17,20 575
1x50 0,386 18,70 736
1x70 0,272 20,50 956
1x95 0,206 23,70 1.262
1x120 0,161 25,60 1.532
1x150 0,129 27,80 1.839
1x185 0,106 29,95 2.176
1x240 0,0801 34,15 2.880
1x300 0,0641 36,45 3.465
1x400 0,0486 41,70 4.336
RVMAV-K FB RH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
·
· Installations in premises with special characteristics
Description RVMAV-K FB RH cables, manufactured with a crown shaped aluminium wire armour, which provides a huge protection against rodents and mechanical damages, are indicated for transporting and distributing low voltage power. It is recommended for industrial connections, service connections, internal distribution and outdoor connections and especially in premises with a high
Technical characteristics
1. Conductor
2. Insulation Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Crown shaped aluminium wire
5. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colors according to UNE 21089 and HD 308S2
·
· Flame retardant according to UNE-EN 60332, EN 60332 and IEC 60332
· Hydrocarbons resistant according to UIC 895 OR
· PVC with reduced hydrogen chloride (HCL) emission
· Cross-linked polyethylene (XLPE) admits a higher current density than a PVC isolation with the same section
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
69
www.cablesrct.com
90ºmax
RVMV-K FB RH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
·
· Installations in premises with special characteristics
Description
RVMV-K FB RH cables, manufactured with a crown shaped steel wire armour, which provides a huge protection against rodents and mechanical damages, are indicated for transporting and distributing low voltage power. It is recommended for industrial connections,
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to UNE-EN 60228, EN 60228 and IEC 602288
2. Insulation Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding PVC
4. Armour Crown shaped galvanized steel wire
5. Sheathing
Rated voltage 0,6/1kV
Test volatge 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colors according to UNE 21089 and HD 308S2
·
· Flame retardant according to UNE-EN 60332, EN 60332 and IEC 60332
· Hydrocarbons resistant according to UIC 895 OR
· PVC with reduced hydrogen chloride (HCL) emission
· Cross-linked polyethylene (XLPE) admits a higher current density than a PVC isolation with the same section
70
www.cablesrct.com
2x2,5 7,98 13,20 339
2x4 4,95 14,50 415
2x6 3,30 16,55 606
2x10 1,91 18,20 767
2x16 1,21 22,65 1.222
3x1,5 13,30 12,40 301
3x2,5 7,98 13,25 354
3x4 4,95 16,00 573
3x6 3,30 17,15 681
3x10 1,91 19,55 894
4x1,5 13,30 13,10 336
4x2,5 7,98 14,05 401
4x4 4,95 17,20 658
4x6 3,30 18,65 795
4x10 1,91 21,80 1.182
4x16 1,21 25,20 1.606
4x25 0,78 29,20 2.155
5x1,5 13,30 14,65 413
5x2,5 7,98 16,70 607
5x4 4,95 18,40 752
5x6 3,30 19,70 900
5x10 1,91 23,10 1.353
5x16 1,21 26,95 1.834
5x25 0,78 32,40 2.728
RVMV-K FB RH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
71
www.cablesrct.com
90º
2x2,5 7,41 8,10 612x4 4,61 9,00 912x6 3,08 10,70 1322x10 1,83 12,30 2082x16 1,15 14,00 3162x25 0,727 16,40 4853x2,5 7,41 9,00 923x4 4,61 9,95 1373x6 3,08 11,55 1984x2,5 7,41 9,80 1224x4 4,61 10,90 1834x6 3,08 12,95 2644x10 1,83 14,85 4164x16 1,15 16,90 6324x25 0,727 19,80 9704x35 0,524 25,35 1.4325x2,5 7,41 10,95 1535x4 4,61 12,20 2285x6 3,08 14,45 3305x10 1,83 16,65 5195x16 1,15 18,95 7905x25 0,727 22,15 1.213
RZ
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Overhead networks
· Overhead supply networks for outdoor lighting installations
· Overhead service connections
· Indoor or receiver installations
Description These cables are indicated for distribution of low voltage electricity in overhead networks and on walls as well as for overhead outdoor lighting installations.
Technical characteristics1. Conductor Electrolytic copper conductor (Class I and II), according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation Special cross-linked polyethylene insulation (XLPE) to support outdoor weather conditions accor-ding to UNE 21030-2
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Its formulation provides protected insulation to support outdoor weather conditions
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
72
www.cablesrct.com
90ºmax
RV-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Description These cables are indicated for the transport and distribution of low voltage electricity. Recommended for industrial connections, ser-vice connections, internal distribution and outdoor connections. It can be used in underground networks and permanent installations.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS
6360), UNE 60228 and IEC 60228
2. Insulation Cross-linked polyethylene insulation(XLPE), type DIX-3, according to HD 603S1
3. Sheathing PVC sheath, type DMV-18, according to HD 603S1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
· PVC with reduced hydrogen chloride (HCL) emission
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Outdoor lighting installations
· Indoor or receiver installations
· Installations in premises with special characteristics
73
www.cablesrct.comRV-K
1x1,5 13,30 4,75 32
1x2,5 7,98 5,15 43
1x4 4,95 5,70 58
1x6 3,30 6,25 78
1x10 1,91 7,15 117
1x16 1,21 8,20 171
1x25 0,78 9,85 254
1x35 0,554 11,05 345
1x50 0,386 12,65 479
1x70 0,272 14,70 670
1x95 0,206 16,80 878
1x120 0,161 18,85 1.116
1x150 0,129 20,85 1.383
1x185 0,106 23,00 1.644
1x240 0,0801 26,10 2.201
1x300 0,0641 28,20 2.682
1x400 0,0486 31,30 3.373
2x1,5 13,30 8,10 89
2x2,5 7,98 8,90 116
2x4 4,95 10,05 158
2x6 3,30 11,15 208
2x10 1,91 12,95 310
2x16 1,21 15,75 496
2x25 0,78 19,05 741
2x35 0,554 21,45 987
2x50 0,386 24,65 1.357
3x1,5 13,30 8,55 104
3x2,5 7,98 9,40 139
3x4 4,95 10,60 192
3x6 3,30 11,80 257
3x10 1,91 13,75 392
3x16 1,21 16,70 620
3x25 0,78 20,25 929
3x35 0,554 22,85 1.250
3x50 0,386 26,30 1.731
3x70 0,272 30,90 2.431
4x1,5 13,30 9,20 123
4x2,5 7,98 10,20 167
4x4 4,95 11,55 235
4x6 3,30 12,90 317
4x10 1,91 15,05 488
4x16 1,21 18,30 768
4x25 0,78 22,30 1.156
4x35 0,5554 25,20 1.563
4x50 0,386 29,05 2.173
4x70 0,272 34,15 3.058
4x95 0,206 39,05 3.998
4x120 0,161 44,20 5.112
4x150 0,129 48,90 6.330
4x185 0,106 54,25 7.588
4x240 0,0801 61,60 10.115
5x1,5 13,30 10,00 144
5x2,5 7,98 11,05 197
5x4 4,95 12,60 279
5x6 3,30 14,10 379
5x10 1,91 16,55 588
5x16 1,21 20,05 923
5x25 0,78 24,50 1.392
5x35 0,5554 27,75 1.888
5x50 0,386 32,25 2.645
5x70 0,272 38,00 3.723
5x95 0,206 43,40 4.867
5x120 0,161 49,30 6.243
5x150 0,129 54,35 7.707
5x185 0,106 60,50 9.256
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Cables available up to 61 conductors. Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
74
www.cablesrct.com
90ºmax AS
RZ1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications · Underground supply networks for outdoor lighting installations
· Underground networks for low voltage distribution
· Electricity distribution networks. Underground service connections
· Installations in premises with special characteristics
Description These halogen-free cables are suitable for transport and permanent installations, protected or unprotected, where low fumes and co-
installations.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to previously BS EN 60228:2005
2. Insulation Cross-linked polyethylene insulation(XLPE), type DIX-3, according to HD 603S1
3. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours UNE 21089 and HD 303S2:2001
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
75
www.cablesrct.com
1x1,5 13,30 4,80 34
1x2,5 7,98 5,20 45
1x4 4,95 5,80 61
1x6 3,30 6,35 80
1x10 1,91 7,25 120
1x16 1,21 8,30 174
1x25 0,78 9,95 258
1x35 0,554 11,15 349
1x50 0,386 12,75 484
1x70 0,272 14,80 676
1x95 0,206 16,90 885
1x120 0,161 18,95 1.124
1x150 0,129 20,95 1.393
1x185 0,106 23,10 1.655
1x240 0,0801 26,20 2.214
1x300 0,0641 28,35 2.697
1x400 0,0486 31,40 3.389
2x1,5 13,30 8,25 94
2x2,5 7,98 9,05 122
2x4 4,95 10,20 165
2x6 3,30 11,30 216
2x10 1,91 13,10 319
2x16 1,21 16,40 503
2x25 0,78 19,70 743
2x35 0,554 22,10 983
2x50 0,386 25,30 1.344
2x70 0,272 29,40 1.860
2x95 0,206 33,30 2.408
3x1,5 13,30 8,65 109
3x2,5 7,98 9,50 144
3x4 4,95 10,75 199
3x6 3,30 11,95 265
3x10 1,91 13,85 401
3x16 1,21 17,35 631
3x25 0,78 20,90 938
3x35 0,554 23,45 1.255
3x50 0,386 26,90 1.730
3x70 0,272 31,50 2.422
3x95 0,206 35,70 3.140
3x120 0,161 40,15 3.989
3x150 0,129 44,00 4.898
3x185 0,106 48,65 5.853
3x240 0,0801 54,90 7.751
4x1,5 13,30 9,35 129
4x2,5 7,98 10,30 173
4x4 4,95 11,70 242
4x6 3,30 13,00 325
4x10 1,91 15,20 498
4x16 1,21 18,90 783
4x25 0,78 22,90 1.168
4x35 0,554 25,80 1.573
4x50 0,386 29,65 2.178
4x70 0,272 34,80 3.055
4x95 0,206 39,70 3.985
4x120 0,161 44,85 5.086
4x150 0,129 49,55 6.294
4x185 0,106 54,90 7.534
4x240 0,0801 62,30 10.034
5x1,5 13,30 10,10 150
5x2,5 7,98 11,20 204
5x4 4,95 12,75 286
5x6 3,30 14,20 387
5x10 1,91 16,65 598
5x16 1,21 20,70 939
5x25 0,78 25,15 1.407
5x35 0,554 28,40 1.901
5x50 0,386 32,90 2.654
5x70 0,272 38,60 3.725
5x95 0,206 44,05 4.860
5x120 0,161 49,95 6.226
5x150 0,129 55,00 7.677
5x185 0,106 59,70 8.999
6x1,5 13,30 10,90 172
6x2,5 7,98 12,10 236
6x4 4,95 13,85 334
7x1,5 13,30 10,90 188
7x2,5 7,98 12,10 260
7x4 4,95 13,85 371
7x6 3,30 15,50 508
8x1,5 13,30 11,75 210
8x2,5 7,98 13,05 292
10x1,5 13,30 12,55 247
10x2,5 7,98 14,00 348
12x1,5 13,30 13,40 285
12x2,5 7,98 14,95 404
14x1,5 13,30 14,25 323
14x2,5 7,98 15,90 460
14x4 4,95 18,35 670
16x1,5 13,30 15,05 360
16x2,5 7,98 16,90 516
19x1,5 13,30 15,90 414
19x2,5 7,98 17,85 596
24x1,5 13,30 17,60 505
24x2,5 7,98 19,80 733
30x1,5 13,30 19,30 612
30x2,5 7,98 21,75 893
37x1,5 13,30 21,00 734
37x2,5 7,98 23,70 1.078
RZ1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Cables 0,6/1kV
Cables available up to 61 conductors.Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
76
www.cablesrct.com
90ºmax AS
3x6+1,5 3,3/13,3 11,70 267
3x10+1,5 1,91/13,3 13,65 399
3x16+1,5 1,21/3,3 15,95 580
3x25+1,5 0,78/13,3 19,85 899
3x35+1,5 0,554/13,3 21,95 1.182
3x50+1,5 0,386/13,3 30,60 1.746
3x70+1,5 0,272/13,3 27,35 2.437
5x6+1,5 3,3/13,3 14,10 405
5x10+1,5 1,91/13,3 16,80 632
5x16+1,5 1,21/3,3 19,60 930
5x25+1,5 0,78/13,3 24,40 1.388
5x35+1,5 0,554/13,3 27,65 1.894
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
RZ1-K (AS) Individual by-pass
Applications
· Individual by-pass
Description These halogen-free cables are suitable for the execution of individual by-passes, in those cases where the supply is carried
section conductor, incorporating it onto the inside of the sheath. The aim of this product is to facilitate installation, reducing the time spent handling each conductor individually, as well as to avoid possible damage to the tracer thread due to its reduced
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21223 and HD 603S1
3. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
· The use of Cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
77
www.cablesrct.com
90ºmax AS
RZ1FAZ1 (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Sub-surface power source networks for outside lighting installations· General supply line· Individual bypass· Indoor or receptor installations· Public premises· Sub-surface networks for low voltage distribution· Electric energy distribution networks. Sub-surface supply lines· Installations in premises with special characteristics
Description These cables are indicated for executing permanent installations where low fumes and corrosive gas emission is required in the event
installations.
1. Conductor Rigid electrolytic copper conductor (Class I-II) according to UNE EN 60228, EN 60228 und IEC 60228
2. Insulation Cross-linked polyethylene insulation(XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Reinforcement seat
4. Metallic reinforcement Double aluminium tape armour
5. Casing
Nominal voltage 0.6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90ºC
Other characteristics
· Colours in compliance with UNE 21089 and HD 308S2
· Low halogen content in compliance with UNE-EN 50267, EN 50267 and IEC 60754
· Low emission of corrosive gases in compliance with UNE-EN 50267, EN 50267 and IEC 60754
· Low emission of opaque fumes in compliance with UNE-EN 61034, EN 61034 and IEC 61034
· The use of cross-linked polyethylene (XLPE) allows a greater density of current with the same given cross-section, when compared to insulation with PVC
78
www.cablesrct.com
1x6 3,08 11,43 215
1x10 1,83 12,30 260
1x16 1,15 13,20 325
1x25 0,727 14,70 440
1x35 0,524 15,75 545
1x50 0,387 17,05 685
1x70 0,268 18,80 905
1x95 0,193 20,67 1.180
1x120 0,153 22,55 1.450
1x150 0,124 24,64 1.740
1x185 0,0991 26,26 2.115
1x240 0,0754 28,91 2.695
1x300 0,0601 31,51 3.310
1x400 0,0470 34,92 4.185
RZ1FAZ1 (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
79
www.cablesrct.com
90ºmax AS
RZ1FZ1 (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Sub-surface power source networks for outside lighting installations· General supply line· Individual bypass· Indoor or receptor installations· Public premises· Sub-surface networks for low voltage distribution· Electric energy distribution networks. Sub-surface supply lines· Installations in premises with special characteristics
Description The RZ1FZ1 (AS) cables are recommended to carry out permanent installations wherever a low emission of corrosive fumes and gases
installations.
1. ConductorElectrolytic copper conductor, Class I and II, according to BS EN 60228:2005 (previously BS6360) and UNE 60228
2. Insulation Cross-linked polyethylene (XLPE), type DIX-3 in compliance with UNE 21123 and HD 603S1
3. Reinforcement seat
4. Metallic reinforcement Steel strip
5. Casing
Nominal voltage 0.6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90ºC
Other characteristics
· Colours in compliance with UNE 21089 and HD 308S2
· Low halogen content in compliance with UNE-EN 50267, EN 50267 and IEC 60754
· Low emission of corrosive gases in compliance with UNE-EN 50267, EN 50267 and IEC 60754
· Low emission of opaque fumes in compliance with UNE-EN 61034, EN 61034 and IEC 61034
· The use of cross-linked polyethylene (XLPE) allows a greater density of current with the same given cross-section, when compared to insulation with PVC
80
www.cablesrct.com
2x1,5 13,30 10,60 207
2x2,5 7,98 11,50 249
2x4 4,95 12,90 318
2x6 3,30 13,70 475
2x10 1,91 16,80 567
2x16 1,21 19,80 793
2x25 0,780 21,80 1.041
3x1,5 13,30 11,00 227
3x2,5 7,98 12,00 332
3x4 4,95 13,50 361
3x6 3,30 15,40 452
3x10 1,91 17,60 663
3x16 1,21 20,20 910
3x25 0,780 23,00 1.268
3x35 0,554 24,80 1.510
4x1,5 13,30 11,80 260
4x2,5 7,98 12,90 322
4x4 4,95 14,50 419
4x6 3,30 15,50 510
4x10 1,91 19,00 817
4x16 1,21 21,80 995
4x25 0,780 25,00 1.566
4x35 0,554 28,10 2.035
4x50 0,386 33,20 2.805
4x70 0,272 38,90 4.226
5x1,5 13,30 12,60 297
5x2,5 7,98 13,80 425
5x4 4,95 15,60 489
5x6 3,30 19,70 660
5x10 1,91 22,10 962
5x16 1,21 25,70 1.355
5x25 0,780 29,40 1.945
5x35 0,554 30,84 2.339
5x50 0,386 38,00 3.222
RZ1FZ1 (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufacturedwith one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
81
www.cablesrct.com
90ºmax AS
RZ1FAZ1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
Underground supply networks for outdoor lighting installations
They can also be used in the following applications:
· Underground networks for low voltage distribution
· Electricity distribution networks. Underground service connections
· Installations in premises with special characteristics
Description These cables are indicated for executing permanent installations where low fumes and corrosive gas emission is required in the event
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V), according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation(XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding
4. Armour Double aluminium tape armour
5. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other charactertics
· Colours according to UNE 21089 and HD 303S2:2001
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
82
www.cablesrct.com
1x4 4,95 10,90 169
1x6 3,30 11,55 199
1x10 1,91 12,75 260
1x16 1,21 13,70 326
1x25 0,78 15,05 423
1x35 0,554 16,75 550
1x50 0,386 17,85 688
1x70 0,272 19,90 908
1x95 0,206 21,85 1.136
1x120 0,161 23,90 1.402
1x150 0,129 25,70 1.685
1x185 0,106 27,85 2.003
1x240 0,0801 30,95 2.593
1x300 0,0641 33,10 3.119
RZ1FAZ1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
83
www.cablesrct.com
90ºmax AS
RZ1FZ1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground supply networks for outdoor lighting installations
· Underground networks for low voltage distribution
· Electricity distribution networks. Underground service connections
· Installations in premises with special characteristics
Description These cables are indicated for executing permanent installations where low smoke and corrosive gas emission is required, in the event
Technical characteristics
1. ConductorFlexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS 6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Armour bedding
4. Armour Double steel tape armour
5. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
84
www.cablesrct.com
2x1,5 13,30 10,60 207
2x2,5 7,98 11,50 249
2x4 4,95 12,90 318
2x6 3,30 13,70 475
2x10 1,91 16,80 567
2x16 1,21 19,80 793
2x25 0,780 21,80 1.041
3x1,5 13,30 11,00 227
3x2,5 7,98 12,00 332
3x4 4,95 13,50 361
3x6 3,30 15,40 452
3x10 1,91 17,60 663
3x16 1,21 20,20 910
3x25 0,780 23,00 1.268
3x35 0,554 24,80 1.510
4x1,5 13,30 11,80 260
4x2,5 7,98 12,90 322
4x4 4,95 14,50 419
4x6 3,30 15,50 510
4x10 1,91 19,00 817
4x16 1,21 21,80 995
4x25 0,780 25,00 1.566
4x35 0,554 28,10 2.035
4x50 0,386 33,20 2.805
4x70 0,272 38,90 4.226
5x1,5 13,30 12,60 297
5x2,5 7,98 13,80 425
5x4 4,95 15,60 489
5x6 3,30 19,70 660
5x10 1,91 22,10 962
5x16 1,21 25,70 1.355
5x25 0,780 29,40 1.945
5x35 0,554 30,84 2.339
5x50 0,386 38,00 3.222
RZ1FZ1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufacturedwith one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
85
www.cablesrct.com
AS+400º
RZ1-K mica (AS+)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
Description
These cables are suitable for the transport and distribution of electricity in permanent installations, having been designed to be able
must not emit acid or toxic gases so they guarantee the safety of people and of the installations, at the same time as they facilitate the evacuation and intervention of the emergency teams on emitting reduced opacity gases.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V), according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation Mica tape / Cross-linked polyethylene (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
· Fire resistance according to UNE-EN 50200, EN 50200, UNE-EN 50362, EN 50362 and IEC60331
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
86
www.cablesrct.comRZ1-K mica (AS+)
1x1,5 13,30 6,50 48
1x2,5 7,98 6,90 65
1x4 4,95 7,40 80
1x6 3,30 7,00 100
1x10 1,91 8,90 142
1x16 1,21 10,80 196
1x25 0,78 11,90 287
1x35 0,554 13,00 385
1x50 0,386 14,50 525
1x70 0,272 18,50 704
1x95 0,206 19,50 931
1x120 0,161 21,50 1.188
1x150 0,129 23,70 1.460
1x185 0,106 28,00 1.775
1x240 0,0801 30,60 2.275
1x300 0,0641 31,00 2.847
2x1,5 13,3 9,10 112
2x2,5 7,98 9,50 186
2x4 4,95 11,80 229
2x6 3,30 13,10 285
2x10 1,91 16,35 400
2x16 1,21 18,15 541
2x25 0,78 20,50 758
3x1,5 13,30 10,20 129
3x2,5 7,98 10,80 211
3x4 4,95 11,20 265
3x6 3,30 14,60 336
3x10 1,91 16,90 484
3x16 1,21 19,30 669
3x25 0,78 22,95 973
3x35 0,554 25,55 1.301
3x50 0,386 29,25 1.784
4x1,5 13,30 11,30 154
4x2,5 7,98 11,80 252
4x4 4,95 15,30 320
4x6 3,30 16,50 411
4x10 1,91 19,50 598
4x16 1,21 22,70 931
4x25 0,78 27,10 1.240
4x35 0,554 28,00 1.560
4x50 0,386 33,50 2.202
4x70 0,272 38,00 3.002
4x95 0,206 45,80 4.098
4x120 0,161 48,00 5.145
4x150 0,129 54,15 6.486
4x185 0,106 62,00 7.935
5x1,5 13,30 12,50 184
5x2,5 7,98 13,20 298
5x4 4,95 14,80 382
5x6 3,30 16,20 494
5x10 1,91 21,50 725
5x16 1,21 24,00 1.019
5x25 0,78 28,60 1.552
5x35 0,554 34,80 1.951
5x50 0,386 38,00 2.755
5x70 0,272 41,65 4.614
5x95 0,206 48,85 6.381
5x120 0,161 53,80 7.982
6x1,5 13,30 12,80 207
6x2,5 7,98 13,95 277
7x1,5 13,30 12,80 224
7x2,5 7,98 13,95 304
8x1,5 13,30 13,85 250
8x2,5 7,98 16,20 350
10x1,5 13,30 14,85 294
10x2,5 7,98 16,20 404
12x1,5 13,30 15,85 338
12x2,5 7,98 17,35 468
14x1,5 13,30 16,90 382
14x2,5 7,98 18,50 537
16x1,5 13,30 17,95 427
16x2,5 7,98 19,65 597
19x1,5 13,30 18,95 488
19x2,5 7,98 20,80 688
24x1,5 13,30 22,10 603
24x2,5 7,98 24,30 854
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
87
www.cablesrct.com
AS+400º
RZ1FZ1-K mica (AS+)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Aplications
· Public premises
Description
easing the evacuation and intervention of the emergency teams because emitting low opacity gases. The metallic band provides a
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Mica tape / cross-linked polyethylene (XLPE), type DIX-3 according to UNE 21123 and HD 603S1
3. Armour bedding
4. Metallic armour Steel band
5. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2
· Fire resistance according to UNE-EN 50200, EN 50200, UNE-EN 50362 and EN 50362
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034, IEC 61034
88
www.cablesrct.com
1x1,5 13,30 10,30 135
1x2,5 7,98 10,65 152
1x4 4,95 11,20 172
1x6 3,30 12,15 206
1x10 1,91 13,10 259
1x16 1,21 14,80 349
1x25 0,78 16,00 438
1x35 0,554 17,70 555
1x50 0,386 19,70 723
1x70 0,272 21,40 925
1x95 0,206 21,30 1.044
1x120 0,161 25,70 1.436
1x150 0,129 27,35 1.731
1x185 0,106 29,65 2.013
1x240 0,0801 33,35 2.601
1x300 0,0641 33,80 3.433
1x400 0,0486 38,45 4.410
2x1,5 13,30 11,65 187
2x2,5 7,98 13,90 273
2x4 4,95 13,50 260
2x6 3,30 15,35 326
2x10 1,91 17,25 431
2x16 1,21 20,70 608
2x25 0,78 23,10 784
2x35 0,554 26,45 1.016
3x1,5 13,30 12,15 214
3x2,5 7,98 13,00 256
3x4 4,95 14,15 309
3x6 3,30 16,15 396
3x10 1,91 18,20 539
3x16 1,21 21,95 780
3x25 0,78 24,50 1.027
3x35 0,554 28,10 1.351
3x50 0,386 32,40 1.823
4x1,5 13,30 13,00 248
4x2,5 7,98 13,95 302
4x4 4,95 15,25 369
4x6 3,30 17,50 478
4x10 1,91 19,80 664
4x16 1,21 23,95 975
4x25 0,78 26,85 1.299
4x35 0,554 30,90 1.723
4x50 0,386 35,70 2.345
4x70 0,272 39,80 3.111
4x95 0,206 44,65 4.003
4x120 0,161 49,70 5.013
4x150 0,129 53,35 6.110
4x185 0,106 58,90 7.179
5x1,5 13,30 13,95 286
5x2,5 7,98 15,00 352
5x4 4,95 16,45 435
5x6 3,30 18,95 569
5x10 1,91 23,00 887
5x16 1,21 26,20 1.187
5x25 0,78 29,40 1.591
5x35 0,554 33,95 2.124
5x50 0,386 39,35 2.906
5x70 0,272 43,95 3.870
5x95 0,206 49,35 4.994
5x120 0,161 55,05 6.270
RZ1-K mica (AS+)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
0,6/1kV Cables
89
www.cablesrct.com
NYY
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Underground networks for low voltage distribution
· Underground feed networks for external lighting installations
· Electric energy distribution networks. Underground water or gas connections
· Internal or receiver installations
· Installations on premises with special characteristics
Description These cables are suitable for transport and distribution of low voltage electrical energy. Recommended for industrial installations, water
Made in accordance with regulation VDE 0276.
Technical characteristics1. Conductor Rigid electrolytic copper (Class I and II) in accordance with DIN VDE 0295, UNE-EN 60228, EN
60228 and IEC 60228
2. Insulation PVC type DIV4 in accordance with DIN VDE 0276
3. Filling PVC
4. Cover PVC type DMV5 in accodance with IEC 60502-1
Nominal voltage 0,6/1kV
Test volatge 3.500V in C.A.
Maximum temperature 70 ºC
Other characteristics
· Made in accordance with VDE 0276
· Colours in accordance with VDE 0293-308, 0276 part 603 and HD 186
·
· PVC cover with low hydrochloric acid emission (HCL)
· NYY-J cables are made with a yellow/green conductor
· NYY-O cables are made without a yellow/green conductor
90
www.cablesrct.com
1x1,5 12,10 6,65 59
1x2,5 7,41 7,00 71
1x4 4,61 7,80 96
1x6 3,08 8,50 123
1x10 1,83 9,15 165
1x16 1,15 10,20 229
1x25 0,727 11,85 336
1x35 0,524 13,40 438
1x50 0,387 14,55 571
1x70 0,268 16,60 793
1x95 0,193 18,80 10.71
1x120 0,153 20,30 1.318
1x150 0,124 22,30 1.579
1x185 0,101 24,60 1.990
1x240 0,0775 27,40 2.531
1x300 0,062 30,10 3.157
2x1,5 12,10 9,80 141
2x2,5 7,41 10,60 175
2x4 4,61 12,25 247
2x6 3,08 13,70 320
2x10 1,83 15,50 440
2x16 1,15 17,30 599
2x25 0,727 20,80 895
2x35 0,524 23,00 1..152
3x1,5 12,10 10,25 162
3x2,5 7,41 11,10 204
3x4 4,61 12,95 291
3x6 3,08 14,40 384
3x10 1,83 16,40 538
3x16 1,15 18,30 748
3x25 0,727 22,05 1125
3x35 0,524 24,40 1463
4x1,5 12,10 11,00 189
4x2,5 7,41 11,95 242
4x4 4,61 14,00 350
4x6 3,08 15,65 464
4x10 1,83 17,80 658
4x16 1,15 20,00 925
4x25 0,727 24,15 1.400
4x35 0,524 26,80 1.829
4x50 0,387 30,90 2.449
4x70 0,268 34,90 3.804
4x95 0,193 40,05 5.179
4x120 0,153 44,55 5.769
5x1,5 12,10 11,80 218
5x2,5 7,41 12,85 282
5x4 4,61 15,15 411
5x6 3,08 17,05 549
5x10 1,83 19,40 784
5x16 1,15 21,85 1.110
5x25 0,727 26,50 1.685
5x35 0,524 29,70 2.223
5x50 0,387 33,80 2.769
5x70 0,268 39,60 4.174
5x150 0,124 57,50 8.934
7x1,5 12,10 13,05 269
7x2,5 7,41 13,40 310
12x1,5 12,10 15,30 400
12x2,5 7,41 16,05 507
19x1,5 12,10 18,00 573
NYY
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
RE: 1 single round conductor wire, Class IRM: Multi-conductor round cable, Class II
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
91
www.cablesrct.com
90ºmax
N2XY 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications · Sub-surface networks for low voltage distribution· Sub-surface power source networks for outside lighting installations· Electric energy distribution networks. Sub-surface supply lines· Interior or receptor installations· Installations in premises with special characteristics
Description N2XY 0.6/1kV cables are those recommended for transport and distribution of low voltage electrical energy. Recommended for indus-trial connections, supplies, internal distribution and outdoor connections. They can be used in sub-surface networks and permanent installations.
1. Conductor Rigid electrolytic copper (Class I and II) in compliance with DIN-VDE 0295, UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Cross-linked polyethylene (VPE), type DIX 3 in compliance with DIN VDE 0276-603 and HD 603S1
3. Casing PVC, type DMV 6 in compliance with DIN VDE 0276-603 and HD 603S1
Nominal voltage 0.6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Built in compliance with VDE 0276-603
· Colours in compliance with VDE 0293-308, VDE 0276 part 603 and HD 308S2
·
· PVC casing for reduced hydrochloric acid (HCL) emission
· The use of cross-linked polyethylene(VPE) allows a greater density of current with the same given cross-section, when compared to insulation with PVC
· The N2XY-J cables are manufactured with a yellow/green conductor
· The N2XY-JO cables are manufactured without a yellow/green conductor
92
www.cablesrct.com
1x1,5 RE 12,10 5,20 40,06
1x2,5 RE 7,41 5,60 51,93
1x4 RE 4,61 6,10 68,97
1x6 RE 3,08 6,60 90,41
1x10 RM 1,83 7,40 131,75
1x16 RM 1,15 8,31 191,71
1x25 RM 0,727 9,92 288,26
1x35 RM 0,524 11,10 387,65
1x50 RM 0,387 12,70 538,19
1x70 RM 0,268 14,41 735,52
1x95 RM 0,193 16,12 975,44
1x120 RM 0,153 17,84 1.219,85
1x150 RM 0,124 19,76 1.516,89
1x185 RM 0,0991 21,80 1.862,49
1x240 RM 0,0754 24,36 2.390,90
2x1,5 RE 12,10 9,06 114,01
2x2,5 RE 7,41 9,92 146,87
2x4 RE 4,61 10,99 193,72
2x6 RE 3,08 12,06 250,89
2x10 RM 1,83 13,77 359,60
2x16 RM 1,15 15,70 512,94
2x25 RM 0,727 18,91 769,23
2x35 RM 0,524 21,26 1.021,70
3x1,5 RE 12,10 9,54 133,15
3x2,5 RE 7,41 10,47 84,03
3x4 RE 4,61 11,62 175,52
3x6 RE 3,08 12,78 236,33
3x10 RM 1,83 14,63 311,73
3x16 RM 1,15 16,71 456,34
3x25 RM 0,727 20,17 662,85
3x35 RM 0,524 22,72 1.001,62
4x1,5 RE 12,10 10,32 1.341,69
4x2,5 RE 7,41 11,36 160,01
4x4 RE 4,61 12,65 213,90
4x6 RE 3,08 13,95 291,51
4x10 RM 1,83 16,02 388,31
4x16 RM 1,15 18,35 574,66
4x25 RM 0,727 22,23 841,98
4x35 RM 0,524 25,08 1.278,53
5x1,5 RE 12,10 11,16 1.719,45
5x2,5 RE 7,41 12,31 189,87
5x4 RE 4,61 13,76 256,13
5x6 RE 3,08 15,20 471,32
5x10 RM 1,83 17,52 701,95
5x16 RM 1,15 20,12 1.033,43
5x25 RM 0,727 24,45 1.574,52
5x35 RM 0,524 27,63 2.122,18
N2XY 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
93
www.cablesrct.com
90ºmax AS
N2XH 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
0,6/1kV Cables
Applications
· Sub-surface power source networks for outdoor lighting installations· General supply line· Individual bypass· Interior or receptor installations· Public premises· Sub-surface networks for low voltage distribution· Electric energy distribution networks. Sub-surface supply lines· Installations in premises with special features
Description The N2XY 0.6/1kV cables are those recommended to transport and distribute low voltage electrical energy. Recommended for indus-trial connections, supplies, internal distribution and outdoor connections. They can be used in sub-surface networks and permanent installations.
1. Conductor Rigid electrolytic copper (Class I or II) in compliance with DIN-VDE 0295, UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Cross-linked polyethylene (VPE), type DIX 3 in compliance with DIN VDE 0276-603 and HD 603S1
3. Casing
Nominal voltage 0.6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Built in compliance with VDE 0276-604
· Colours in compliance VDE 0293-308, VDE 0276 part 603, HD 308S2, EN 50334 and VDE 0293-334
· Low emission of halogen and corrosive gases in compliance with DIN VDE 0482 part 267-2-2
· Low emission of opaque fumes in compliance with DIN VDE 0482 part 268
· The use of cross-linked polyethylene (XLPE) allows a greater density of current, equality of cross-section, when compared to insulation with PVC
94
www.cablesrct.com
1,5RE 12,10 5,20 40,06
2,5RE 7,41 5,60 51,93
4RE 4,61 6,10 68,97
6RE 3,08 6,60 90,41
10RM 1,83 7,40 131,75
16RM 1,15 8,31 191,71
25RM 0,727 9,92 288,26
35RM 0,524 11,10 387,65
50RM 0,387 12,70 538,19
70RM 0,268 14,41 735,52
95RM 0,193 16,12 975,44
120RM 0,153 17,84 1.219,85
150RM 0,124 19,76 1.516,89
185RM 0,0991 21,80 1.862,49
240RM 0,0754 24,36 2.390,90
2x1,5RE 12,10 9,06 114,01
2x2,5RE 7,41 9,92 146,87
2x4RE 4,61 10,99 193,72
2x6RE 3,08 12,06 250,89
2x10RM 1,83 13,77 359,60
2x16RM 1,15 15,70 512,94
2x25RM 0,727 18,91 769,23
2x35RM 0,524 21,26 1.021,70
3x1,5RE 12,10 9,54 133,15
3x2,5RE 7,41 10,47 175,52
3x4RE 4,61 11,62 236,33
3x6RE 3,08 12,78 311,73
3x10RM 1,83 14,63 456,34
3x16RM 1,15 16,71 662,85
3x25RM 0,727 20,17 1.001,62
3x35RM 0,524 22,72 1.341,69
4x1,5RE 12,10 10,32 160,01
4x2,5RE 7,41 11,36 213,90
4x4RE 4,61 12,65 291,51
4x6RE 3,08 13,95 388,31
4x10RM 1,83 16,02 574,66
4x16RM 1,15 18,35 841,98
4x25RM 0,727 22,23 1.278,53
4x35RM 0,524 25,08 1.719,45
5x1,5RE 12,10 11,16 189,87
5x2,5RE 7,41 12,31 256,13
5x4RE 4,61 13,76 351,74
5x6RE 3,08 15,20 471,32
5x10RM 1,83 17,52 701,95
5x16RM 1,15 20,12 1.033,43
5x25RM 0,727 24,45 1.574,52
5x35RM 0,524 27,63 2.122,18
N2XH
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Cables 0,6/1kV
Cables available up to 61 conductors.Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
95
www.cablesrct.com
90ºmax
2x1,5 13,30 7,15 52
2x2,5 7,98 7,95 72
ROZ1-K (AS) 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS 6360) and
UNE 60228
2. Insulation Crosslinked polyethylene (XLPE) type DIX 3 according to UNE 21123
3. Screen Polyester tape, tinplated copper drainage wire and polyester aluminium tape
Rated voltage 300/500 V
Test voltage 2.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Primary colours, red and black
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
Applications · Public premises
According to the Regulation on Safety against Fire in Industrial Establishments, 2004.
Description
electrical installations in electromagnetic shielding is required to avoid generation of parasitic currents in other circuits.
the safety of people and of the installations such as public places, hospitals, schools, malls, airports, etc. They are suitable for indoor and outdoor air on stands, pipes or buried.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
96
www.cablesrct.com
90ºmax
2x1,5 13,30 8,20 95
2x2,5 7,98 9,00 138
ROZ1-K mica (AS+) 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS6360) and
UNE 60228
2. Insulation Mica tape
3. Insulation Crosslinked polyethylene (XLPE) type DIX-3 according to UNE 21123
4-5. Screen Polyester tape, tinplated copper drainage wire and polyester aluminium tape
6. Sheathingand with reduced smoke emission and opacity
Rated voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Primary colours, red and black
· Fire resistant according to UNE-EN 50200, EN 50200, EN 50362, EN 50362
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
Applications · Public premises
According to the Regulation on Safety against Fire. In Industrial Establishments, 2004.
Description These ROZ1-K mica (AS+) halogen-free cables are indicated for
detectors, etc. Furthermore, this cable guarantees compliance
standard UNE-EN 50200, thus maintaining the operation of the
established by the REBT in its ITC 28 “public premises”.
the safety of people and of the installations, such as public places, hospitals, schools, malls, airports, etc. They are suitable for indoor and outdoor air on stands, pipes or buried.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
97
www.cablesrct.com
90ºmax
2x1,5 13,30 12 219
2x2,5 7,98 13 272
ROZ1FZ1-K mica (AS+) 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
1. Conductor Flexible electrolytic copper (Class V) in compliance with UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Mica tape
3. Insulation DIX-3-type cross-linked polyethylene (XLPE) in compliance with UNE 21123
4. Shield Polyester tape, tin-plated copper drain-wire and aluminium polyester tape
5. Filler armour
6. Metallic armour Steel strip
7. Outer sheathreduced opacity and smoke emission
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 90 ºC
Other characteristics
· 25 turns/metre· Primary colours red and black· Fire-resistant in compliance with UNE-EN 50200, EN 50200, UNE-EN 50362, EN 50362
· Low halogen content in compliance with UNE-EN 50267, EN 50267 and IEC 60754· Low emission of corrosive gases in compliance with UNE-EN 50267, EN 50267 and IEC 60754· Low emission of opaque fumes in compliance with UNE-EN 61034, EN 61034 and IEC 61034
Applications
In compliance with Low-Voltage Regulations (REBT) 2002:
· ITC-BT 28 Public buildings
Description ROZ1FZl-K mica (AS+) halogen-free cables are intended for use
tons, detectors, etc. running on a non-autonomous power supply in which a low emission of fumes and corrosive gases is required
ping centres, airports, etc. Their steel strip provides them with a high level of protection against rodents and mechanical dam-ages.
98
www.cablesrct.com
LiYCY 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
· Data transfer systems· Electronic controlling and signals · IT systems· Weighing machines, etc.
Description
distortions. They are useful for inverters controlling and commanding applications, electrovalves, automatons and machines start-up,
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS6360) EN
60228 and IEC 60228
2. Insulation PVC type A in accordance with UNE 21123, VDE 0812 and IEC 60502-1
3. Shield Tinned copper braid with a coverage of 85% upon a polyester lamina
4. Cover PVC type ST-1 in accordance with UNE 21123 and IEC 60502-1
Tensión nominal 300/500V
Tensión de ensayo 2.000V in A.C.
Temperatura máxima 70 ºC
Other caracteristics
· Light grey cover RAL 7032
· Approximate inductance 0,65 mH/km
· Altering approximate capacity 120 nF/km Conductor/Conductor
· Altering approximate capacity 160 nF/km Conductor/Shield
·
· Colours in accordance with DIN 47100
·
· Insulation and cover made of PVC with reduced emission of hydrochloric acid (HCL)
99
www.cablesrct.comLiYCY 300/500V
2x0,25 78 5,00 29
2x0,35 56 5,15 32
2x0,5 39 5,85 41
2x0,75 26 6,25 49
2x1 19,50 6,55 56
2x1,50 13,30 7,40 70
3x0,25 78 5,20 35
3x0,35 56 5,40 38
3x0,50 39 6,10 50
3x0,75 26 6,55 60
3x1 19,50 6,90 70
3x1,50 13,30 7,75 89
4x0,25 78 5,60 40
4x0,35 56 5,80 46
4x0,50 39 6,55 59
4x0,75 26 7,05 73
4x1 19,50 7,40 85
4x1,50 13,30 8,40 109
5x0,25 78 6,00 47
5x0,35 56 6,25 54
5x0,50 39 7,05 69
5x0,75 26 7,60 86
5x1 19,50 8,00 100
5x1,50 13,30 9,10 130
6x0,25 78 6,45 54
6x0,35 56 6,70 62
6x0,50 39 7,55 80
6x0,75 26 8,15 99
6x1 19,50 8,65 122
6x1,50 13,30 9,85 158
7x0,25 78 6,85 64
7x0,35 56 7,10 74
7x0,50 39 7,55 87
7x0,75 26 8,15 108
7x1 19,50 8,65 129
7x1,50 13,30 9,85 169
8x0,25 78 7,35 73
8x0,35 56 7,65 84
8x0,50 39 8,60 109
8x0,75 26 9,35 134
8x1 19,50 9,90 162
8x1,50 13,30 11,40 214
10x0,25 78 7,35 76
10x0,35 56 7,65 89
10x0,50 39 8,60 114
10x0,75 26 9,35 144
10x1 19,50 9,90 172
10x1,50 13,30 11,40 228
12x0,25 78 7,85 87
12x0,35 56 8,15 102
12x0,50 39 9,15 131
12x0,75 26 9,90 167
12x1 19,50 10,55 200
12x1,50 13,30 12,15 265
16x0,25 78 8,75 109
16x0,35 56 9,10 129
16x0,50 39 10,20 165
16x0,75 26 11,10 212
16x1 19,50 11,85 256
16x1,50 13,30 13,70 341
20x0,25 78 10,10 140
20x0,35 56 10,50 166
20x0,50 39 11,30 199
20x0,75 26 12,30 257
20x1 19,50 13,15 312
30x0,25 78 11,50 191
30x0,35 56 12,00 229
30x0,50 39 12,90 278
30x0,75 26 14,10 363
30x1 19,50 15,10 443
40x0,25 78 12,90 243
40x0,35 56 13,45 293
40x0,50 39 14,50 356
40x0,75 26 15,95 469
40x1 19,50 17,05 574
50x0,25 78 14,30 294
50x0,35 56 14,95 356
50x0,50 39 16,15 435
50x0,75 26 17,75 574
50x1 19,50 19,05 345
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
100
www.cablesrct.com
YCY / 05VC4V-K 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Applications
· Electronic equipment connections· IT system connections· Variable-speed driver connections· Weighing machine connections, etc.
Description
distortions. They are useful for inverters controlling and commanding applications, electrovalves, automatons and machines start-up,
Technical characteritics1. Conductor Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS6360) EN
60228 and IEC 60228
2. Insulation PVC type A in accordance with UNE 21123, VDE 0812 and IEC 60502-1
3. Shield Copper braid with a coverage of 70% upon a polyester lamina
4. Cover PVC type ST-1 in accordance with UNE 21123 and HD603S1
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours in accordance with UNE 21089 (marked with colours when less than 5) and HD 308S2
· Colours in accordance with UNE-EN 50334 (marked by inscription for more than 5 conductors) and EN 50334
·
· Insulation and cover made of PVC with reduced emission of hydrochloric acid (HCL)
· YCY-JZ: Black numbered conductors with yellow/green
· YCY-OZ: Black numbered conductors without yellow/green
· YCY-JB: Conductor colours in accordance with HD 308S2 with yellow/green
· YCY-OB: Conductor colours in accordance with HD 308S2 without yellow/green
101
www.cablesrct.com
2x0,75 26,00 6,75 53
2x1 19,50 7,00 60
2x1,5 13,30 7,90 76
2x2,5 7,98 9,60 113
2x4 4,95 10,70 151
2x6 3,30 12,10 202
2x10 1,91 15,50 326
2x16 1,21 17,60 459
2x25 0,78 21,60 676
3x0,75 26,00 7,10 66
3x1 19,50 7,40 76
3x1,5 13,30 8,55 101
3x2,5 7,98 10,35 151
3x4 4,95 11,55 204
3x6 3,30 12,80 268
3x10 1,91 16,65 446
3x16 1,21 18,70 625
3x25 0,78 23,15 938
4x0,75 26,00 7,70 80
4x1 19,50 8,20 97
4x1,5 13,30 9,50 129
4x2,5 7,98 11,25 186
4x4 4,95 12,65 256
4x6 3,30 14,20 345
4x10 1,91 18,45 573
4x16 1,21 20,90 816
4x25 0,78 25,80 1223
5x0,75 26,00 8,50 98
5x1 19,50 8,90 114
5x1,5 13,30 10,50 158
5x2,5 7,98 12,45 229
5x4 4,95 14,10 319
5x6 3,30 15,70 423
5x10 1,91 20,55 713
5x16 1,21 23,05 1003
5x25 0,78 28,70 1516
6x0,75 26,00 9,20 117
6x1 19,50 9,80 144
6x1,5 13,30 11,35 193
6x2,5 7,98 13,50 281
YCY / 05VC4V-K 300/500V
7x0,75 26,00 9,20 124
7x1 19,50 9,80 151
7x1,5 13,30 11,35 203
7x2,5 7,98 13,50 297
8x0,75 26,00 11,00 173
8x1 19,50 10,95 186
8x1,5 13,30 13,50 266
8x2,5 7,98 16,25 396
10x0,75 26,00 11,00 175
10x1 19,50 11,70 212
10x1,5 13,30 13,50 284
10x2,5 7,98 16,25 424
12x0,75 26,00 11,70 201
12x1 19,50 12,45 245
12x1,5 13,30 14,40 329
12x2,5 7,98 17,35 493
14x0,75 26,00 12,60 234
14x1 19,50 13,40 284
14x1,5 13,30 15,70 389
14x2,5 7,98 19,05 587
16x0,75 26,00 13,30 264
16x1 19,50 14,15 320
16x1,5 13,30 16,60 439
16x2,5 7,98 20,15 664
19x0,75 26,00 14,00 298
19x1 19,50 14,90 364
19x1,5 13,30 17,50 499
19x2,5 7,98 21,25 757
24x0,75 26,00 16,05 630
24x1 19,50 16,80 459
24x1,5 13,30 19,90 637
24x2,5 7,98 24,05 960
30x0,75 26,00 17,45 461
30x1 19,50 18,30 554
30x1,5 13,30 21,70 769
30x2,5 7,98 26,25 1163
37x0,75 26,00 19,10 558
37x1 19,50 20,25 681
37x1,5 13,30 23,90 942
37x2,5 7,98 28,90 1422
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
102
www.cablesrct.com
YSLCY 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) in accordance with UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation PVC type A in accordance with UNE 21123, VDE 0812 and IEC 60502-1
3. Shield Copper braid with a coverage of 70% upon a polyester lamina
4. Cover PVC type ST-1 in accordance with UNE 21123 and HD603S1
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours in accordance with UNE 21089 (marked with colours when less than 5) and HD 308S2
· Colours in accordance with UNE-EN 50334 (marked by inscription for more than 5 conductors) and EN 50334
·
· Insulation and cover made of PVC with reduced emission of hydrochloric acid (HCL)
· YCY-JZ: Black numbered conductors with yellow/green
· YCY-OZ: Black numbered conductors without yellow/green
· YCY-JB: Conductor colours in accordance with HD 308S2 with yellow/green
· YCY-OB: Conductor colours in accordance with HD 308S2 without yellow/green
Applications
· Electronic equipment connections· IT system connections· Variable-speed driver connections· Weighing machine connections, etc.
Description
distortions. They are useful for inverters controlling and commanding applications, electrovalves, automatons and machines start-up,
103
www.cablesrct.com
2x0,75 26,00 6,75 53
2x1 19,50 7,00 60
2x1,5 13,30 7,90 65
2x2,5 7,98 9,60 113
2x4 4,95 10,70 151
2x6 3,30 12,10 202
2x10 1,91 15,50 326
2x16 1,21 17,60 459
2x25 0,78 21,60 676
3x0,75 26,00 7,10 66
3x1 19,50 7,40 76
3x1,5 13,30 8,55 101
3x2,5 7,98 10,35 151
3x4 4,95 11,55 204
3x6 3,30 12,80 268
3x10 1,91 16,65 446
3x16 1,21 18,70 625
3x25 0,78 23,15 938
4x0,75 26,00 7,70 80
4x1 19,50 8,20 97
4x1,5 13,30 9,50 129
4x2,5 7,98 11,25 186
4x4 4,95 12,55 255
4x6 3,30 14,20 345
4x10 1,91 18,45 573
4x16 1,21 20,90 816
4x25 0,78 25,80 1.223
5x0,75 26,00 8,50 98
5x1 19,50 8,90 114
5x1,5 13,30 10,50 158
5x2,5 7,98 12,45 229
5x4 4,95 14,10 319
5x6 3,30 15,70 423
5x10 1,91 20,55 713
5x16 1,21 23,05 1.003
5x25 0,78 28,70 1.516
6x0,75 26,00 9,20 117
6x1 19,50 9,80 144
6x1,5 13,30 11,35 193
6x2,5 7,98 13,50 281
YSLCY 300/500V
7x0,75 26,00 9,20 124
7x1 19,50 9,80 151
7x1,5 13,30 11,35 203
7x2,5 7,98 13,50 297
8x0,75 26,00 11,00 173
8x1 19,50 11,70 204
8x1,5 13,30 13,50 266
8x2,5 7,98 16,25 396
10x0,75 26,00 11,00 175
10x1 19,50 11,70 212
10x1,5 13,30 13,50 284
10x2,5 7,98 16,25 424
12x0,75 26,00 11,70 201
12x1 19,50 12,45 245
12x1,5 13,30 14,40 329
12x2,5 7,98 17,35 493
14x0,75 26,00 12,60 234
14x1 19,50 13,40 284
14x1,5 13,30 15,70 389
14x2,5 7,98 19,05 587
16x0,75 26,00 13,30 264
16x1 19,50 14,15 320
16x1,5 13,30 16,60 439
16x2,5 7,98 20,15 664
19x0,75 26,00 14,00 298
19x1 19,50 14,90 364
19x1,5 13,30 17,50 499
19x2,5 7,98 21,25 757
24x0,75 26,00 16,05 384
24x1 19,50 16,80 459
24x1,5 13,30 19,90 637
24x2,5 7,98 24,05 960
30x0,75 26,00 17,45 461
30x1 19,50 18,30 554
30x1,5 13,30 21,70 769
30x2,5 7,98 26,25 1.163
37x0,75 26,00 19,10 558
37x1 19,50 20,25 681
37x1,5 13,30 23,90 942
37x2,5 7,98 28,90 1.422
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
104
www.cablesrct.com
H05VVC4V5-K / YSLYCY 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
Suitable for the following installations:
· Data communication systems
· Control and signal in electronics
· Computer systems
· Weighing equipment, etc.
Description H05VVC4V5-K / YSLYCY 300/500V cables are suitable for permanent installations where electromagnetic protection is required to avoid parasitic currents. They are useful in applications for the control and command of inverters, solenoid valves, machine and logic controller start-up, power switches, as well as temperature, current or voltage regulation in motorised valves. Their high versatility
1. Conductor Flexible electrolytic copper (Class V) in compliance with UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation PVC type A in compliance with UNE-EN 50525-2-51
3. Shield cover PVC type ST-1 in compliance with UNE-EN 50525-2-51
4. Shield 70% tinned copper braid on polyester sheet
5. Sheathing PVC with nitrile rubber additive, TM-5 type resistant to oils in compliance with UNE-EN 50525-2-51
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· White RAL 9010, grey RAL 7000, black and transparent· Colours in compliance with UNE 21089 (colour marked for less than 5 conductors) and HD 308S2· Colours in compliance with UNE 50334 (inscription marked for more than 5 conductors) and EN 50334
· Insulation and sheathing in low hydrochloric acid (HCL) emission PVC· YSLYCY-JZ: Black numbered conductors with yellow/green· YSLYCY-OZ: Black numbered conductors without yellow/green· YSLYCY-JB: Conductor colours in accordance with HD 308S2 with yellow/green· YSLYCY-OB: Conductor colours in accordance with HD 308S2 without yellow/green
105
www.cablesrct.com
2x1 19,50 7,70 76
2x1,5 13,30 8,60 95
2x2,5 7,98 9,80 121
3x1 19,50 8,10 88
3x1,5 13,30 9,30 124
3x2,5 7,98 10,90 174
4x1 19,50 8,80 114
4x1,5 13,30 9,80 138
4x2,5 7,98 11,80 213
5x1 19,50 9,60 140
5x1,5 13,30 11,10 185
6x1 19,50 10,80 172
6x1,5 13,30 12,20 224
6x2,5 7,98 13,57 315
7x1,5 13,30 12,20 245
7x2,5 7,98 13,46 330
8x1 19,50 12,00 218
8x1,5 13,30 14,00 288
8x2,5 7,98 14,61 385
10x1 19,50 13,10 239
10x1,5 13,30 15,30 355
10x2,5 7,98 16,98 475
12x1 19,50 13,40 271
12x1,5 13,30 15,70 358
12x2,5 7,98 17,54 530
14x1,5 13,30 16,60 435
16x1 19,50 14,90 350
16x1,5 13,30 17,53 495
19x1 19,50 15,90 402
19x1,5 13,30 18,49 560
24x1,5 13,30 22,00 723
37x1,5 13,30 28,80 1.086
H05VVC4V5-K / YSLYCY 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
106
www.cablesrct.com
05Z1C4Z1-K (AS) 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
Suitable for the following installations:
· Data communication systems
· Control and signal in electronics
· Computer systems
· Weighing equipment, etc.
Description 05Z1C4Z1-K (AS) cables are suitable for permanent installations where electromagnetic protection is required to avoid parasitic cur-rents. They are recommended for use in applications for the control and command of inverters, solenoid valves, machine and logic controller start-up, power switches, temperature, current or voltage regulation in motorised valves as well as for installation in com-puting facilities, airports, road tunnels, railway networks and wherever a low emission of corrosive fumes and gases is required due
1. Conductor Flexible electrolytic copper (Class V) in compliance with UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation
3. Shields 70% copper braid on polyester sheet
4. Casing
Nominal voltage 300/500V
Test voltage 2.000V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours in compliance with UNE 21089 (colour marked for less than 5 conductors) and HD 308S2
· Colour in compliance with UNE 50334 (inscription marked for more than 5 conductors) and EN 50334
· Low halogen content in compliance with UNE-EN 50267, EN 50267 and IEC 60754
· Low emission of corrosive gases in compliance with UNE-EN 50267, EN 50267 and IEC 60754
· Low emission of opaque fumes in compliance with UNE-EN 61034, EN 61034 and IEC 61034
107
www.cablesrct.com
2x0,5 39,00 5,90 402x0,75 26,00 6,55 502x1 19,50 6,85 583x0,5 39,00 6,20 493x0,75 26,00 6,90 633x1 19,50 7,25 734x0,5 39,00 6,95 644x0,75 26,00 7,50 774x1 19,50 7,85 905x0,5 39,00 7,55 755x0,75 26,00 8,40 955x1 19,50 8,80 1126x0,5 39,00 8,35 806x0,75 26,00 9,05 986x1 19,50 9,75 1206x2,5 7,98 16,20 3717x0,5 39,00 8,35 897x0,75 26,00 9,30 1147x1 19,50 9,75 1348x0,5 39,00 9,00 998x0,75 26,00 10,00 1288x1 19,50 10,45 151
10x0,5 39,00 10,05 12910x0,75 26,00 10,90 15810x1 19,50 11,65 19310x2,5 7,98 19,20 53212x0,5 39,00 10,70 14912x0,75 26,00 11,60 18412x1 19,50 12,40 22414x0,5 39,00 11,35 16914x0,75 26,00 12,35 20914x1 19,50 13,20 25516x0,5 39,00 12,20 19516x0,75 26,00 13,50 24816x1 19,50 14,15 29319x0,5 39,00 12,85 22419x0,75 26,00 14,20 28519x1 19,50 14,95 33924x0,5 39,00 14,15 27324x0,75 26,00 15,65 34824x1 19,50 16,45 41527x1 19,50 17,25 46030x0,5 39,00 15,90 34630x0,75 26,00 17,55 44030x1 19,50 18,45 52437x0,5 39,00 17,45 42237x0,75 26,00 19,20 53737x1 19,50 20,40 650
05Z1C4Z1-K (AS) 300/500V
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
108
www.cablesrct.com
VC4V-K 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
· Underground supply networks for outdoor lighting installations
· Indoor or receiver installations
Description These cables are indicated for executing permanent installations where electromagnetic protection is required to avoid parasitic currents. They are useful for control applications of drivers, solenoid valves, start-up of machines and robots, remote switches, tem-
Technical characteristics1. Conductor Flexible electrolytic copper (Class V) according to BS EN 60228:2005 (previously BS 6360) and
UNE 60228
2. Insulation PVC insulation, type A, according to UNE 21123 and IEC 60502-1
3. Screen 70% copper braid on polyester sheet
4. Sheathing PVC sheath type ST-1, according to UNE 21123 and IEC 60502-1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21089 (marked with colours for less than 5 conductors) and HD 308S2:2001
· Colours according to UNE-EN 50334 (marked by inscription for more than 5 conductors) and EN 50334:2001
·
· PVC insulation and sheath with reduced hydrogen chloride (HCL) emission
109
www.cablesrct.comVC4V-K 0,6/1kV
1x6 3,30 7,10 105
1x10 1,91 8,20 155
1x16 1,21 9,20 213
1x25 0,78 10,75 309
1x35 0,554 11,90 405
1x50 0,386 13,50 563
1x70 0,272 15,50 758
1x95 0,206 17,40 1.000
1x120 0,161 19,40 1.234
1x150 0,129 21,70 1.541
1x185 0,106 23,70 1.879
1x240 0,0801 26,80 2.420
1x300 0,0641 30,00 2.970
2x1,5 13,30 8,30 109
2x2,5 7,98 9,10 138
2x4 4,95 9,60 186
2x6 3,30 11,25 241
2x10 1,91 13,40 373
2x16 1,21 15,65 515
2x25 0,78 18,60 773
2x35 0,554 21,50 1.014
2x50 0,386 25,30 1.436
3x1,5 13,30 8,90 128
3x2,5 7,98 9,55 164
3x4 4,95 10,70 223
3x6 3,30 12,15 291
3x10 1,91 14,10 472
3x16 1,21 16,40 661
3x25 0,78 20,10 996
3x35 0,554 22,40 1.316
3x50 0,386 27,35 1.868
3x70 0,272 31,75 2.550
3x95 0,206 37,50 3.425
4x1,5 13,30 9,60 153
4x2,5 7,98 10,55 200
4x4 4,95 11,70 281
4x6 3,30 13,10 370
4x10 1,91 15,70 593
4x16 1,21 17,90 836
4x25 0,78 22,10 1.263
4x35 0,554 24,60 1.696
4x50 0,386 29,20 2.382
4x70 0,272 33,90 3.243
4x95 0,206 38,10 4.284
4x120 0,161 43,50 5.443
4x150 0,129 48,80 6.835
4x185 0,106 54,00 8.316
4x240 0,0801 61,40 10.808
5x1,5 13,30 10,35 183
5x2,5 7,98 11,40 238
5x4 4,95 12,80 339
5x6 3,30 14,10 447
5x10 1,91 17,15 722
5x16 1,21 19,90 1.023
5x25 0,78 24,40 1.568
5x35 0,554 27,10 2.082
5x50 0,386 33,65 2.934
5x70 0,272 38,20 4.063
5x95 0,206 42,20 5.281
5x120 0,161 50,60 6.738
5x150 0,129 58,35 8.485
5x185 0,0641 64,40 10.347
6x1,5 13,30 8,90 240
6x2,5 7,98 12,70 315
7x1,5 13,30 11,40 252
7x2,5 7,98 12,70 348
8x1,5 13,30 11,40 285
8x2,5 7,98 15,85 405
10x1,5 13,30 12,70 336
10x2,5 7,98 17,80 536
12x1,5 13,30 14,20 390
12x2,5 7,98 18,40 561
14x1,5 13,30 14,35 465
14x2,5 7,98 18,65 661
16x1,5 13,30 16,70 490
16x2,5 7,98 19,25 738
19x1,5 13,30 17,30 612
19x2,5 7,98 21,35 836
24x1,5 13,30 18,25 680
24x2,5 7,98 24,90 1.103
30x1,5 13,30 19,35 901
30x2,5 7,98 26,35 1.280
37x1,5 13,30 28,70 1.031
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
110
www.cablesrct.com
90ºmax
RC4V-K 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
· Underground networks for low voltage distribution
· Underground supply networks for outdoor lighting installations
· Electricity distribution networks. Underground service connections
· Indoor or receiver installations
· Installations in premises with special characteristics
Description These cables are indicated for executing permanent installations where electromagnet protection is required to avoid parasitic cu-rrents. Their use is recommended in control applications of drivers, solenoid valves, start-up of machines and robots, remote switches,
Technical characteristics1. Conductor Flexible electrolytic copper (Class V), according to BS EN 60228:2005 (previously BS 6360) and
UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE21123 and HD 603S1
3. Screen 70% copper braid on polyester sheet
4. Sheathing PVC sheath type ST-1, according to UNE 21123 and IEC 60502-1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001·· The use of XLPE admits greater current density, at equal section, respect to the PVC insulation· PVC sheath with reduced hydrogen chloride (HCL) emission
111
www.cablesrct.com
1x2,5 7,98 6,80 60
1x4 4,95 7,00 77
1x6 3,3 7,20 98
1x10 1,91 8,20 142
1x16 1,21 9,20 198
1x25 0,78 10,80 288
1x35 0,554 12,00 383
1x50 0,386 13,50 531
1x70 0,272 15,50 730
1x95 0,206 17,40 950
1x120 0,161 19,40 1.174
1x150 0,129 21,70 1.478
1x185 0,106 23,70 1.793
1x240 0,0801 26,80 2.355
1x300 0,0641 30,00 2.861
2x1,5 13,30 9,20 103
2x2,5 7,98 9,30 134
2x4 4,95 10,30 175
2x6 3,3 11,30 227
2x10 1,91 13,70 348
2x16 1,21 15,65 485
2x25 0,78 19,10 731
2x35 0,554 22,80 949
2x50 0,386 25,30 1.373
3x1,5 13,30 9,50 107
3x2,5 7,98 10,15 147
3x4 4,95 10,70 211
3x6 3,30 12,00 279
3x10 1,91 14,10 435
3x16 1,21 16,40 617
3x25 0,78 20,10 933
3x35 0,554 22,40 1.249
3x50 0,386 26,00 1.772
3x70 0,272 30,60 2.464
3x95 0,206 34,00 3.273
3x120 0,161 39,00 3.968
3x150 0,129 40,00 5.022
3x185 0,106 42,00 6.011
3x240 0,0801 44,00 7.031
4x1,5 13,30 10,00 125
4x2,5 7,98 11,10 190
4x4 4,95 11,70 259
4x6 3,3 13,10 353
4x10 1,91 15,70 542
4x16 1,21 17,90 777
4x25 0,78 22,10 1.179
4x35 0,554 24,60 1.606
4x50 0,386 29,20 2.255
4x70 0,272 33,90 3.159
4x95 0,206 38,10 4.190
4x120 0,161 43,50 5.282
4x150 0,129 48,80 6.582
4x185 0,106 54,00 7.974
4x240 0,0801 61,40 10.453
5x1,5 13,30 11,10 168
5x2,5 7,98 11,40 227
5x4 4,95 12,70 312
5x6 3,30 14,10 425
5x10 1,91 17,15 659
5x16 1,21 19,90 950
5x25 0,78 24,40 1.463
5x35 0,554 27,10 1.970
5x50 0,386 32,95 2.801
5x70 0,272 37,00 3.885
5x95 0,206 45,80 5.168
5x120 0,161 50,60 6.538
5x150 0,129 58,35 8.169
5x185 0,106 64,40 9.930
6x1,5 13,30 11,40 198
6x2,5 7,98 12,70 269
7x1,5 13,30 11,40 230
7x2,5 7,98 12,70 316
7x4 4,95 15,75 409
8x1,5 13,30 12,70 251
8x2,5 7,98 15,85 351
10x1,5 13,30 14,20 321
10x2,5 7,98 17,80 444
12x1,5 13,30 14,35 351
12x2,5 7,98 18,40 487
14x1,5 13,30 16,70 389
14x2,5 7,98 18,65 538
16x1 19,50 16,00 338
16x1,5 13,30 17,30 426
16x2,5 7,98 19,25 610
19x1,5 13,30 18,25 481
19x2,5 7,98 21,35 700
24x1,5 13,30 19,35 636
24x2,5 7,98 24,90 906
30x1,5 13,30 21,60 750
30x2,5 7,98 26,35 1.081
37x1,5 13,30 23,45 1.085
RC4V-K 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
112
www.cablesrct.com
90ºmax AS
RC4Z1-K (AS) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
· Underground supply networks for outdoor lighting installations
· Underground networks for low voltage distribution
· Electricity distribution networks. Underground service connections
· Installations in premises with special characteristics
Description These cables are indicated for executing permanent installations where electromagnetic protection is required to avoid parasitic currents. Their use is recommended in control applications of drivers, solenoid valves, start-up of machines and robots, remote switches, temperature, intensity or voltage regulation in motorised valves as well as for installations in computer centres, airports, road
hospitals, schools and shopping centres.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously
BS 6360) and UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21123 and HD 603S1
3. Screen 70% copper braid on polyester sheet
4. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
113
www.cablesrct.com
1x2,5 7,98 6,80 62
1x4 4,95 7,00 79
1x6 3,30 7,20 101
1x10 1,91 8,20 145
1x16 1,21 9,20 201
1x25 0,78 10,80 292
1x35 0,554 12,00 387
1x50 0,386 13,50 536
1x70 0,272 15,50 735
1x95 0,206 17,40 957
1x120 0,161 19,40 1.182
1x150 0,129 21,70 1.488
1x185 0,106 23,70 1.804
1x240 0,0801 26,80 2.368
1x300 0,0641 30,00 2.875
2x1,5 13,30 9,20 107
2x2,5 7,98 9,90 138
2x4 4,95 10,30 181
2x6 3,30 11,30 234
2x10 1,91 13,70 357
2x16 1,21 15,65 497
2x25 0,78 19,10 748
2x35 0,554 22,80 969
2x50 0,386 25,30 1.401
3x1,5 13,30 9,60 123
3x2,5 7,98 10,15 151
3x4 4,95 10,70 217
3x6 3,30 12,00 285
3x10 1,91 14,10 444
3x16 1,21 16,40 628
3x25 0,78 20,10 949
3x35 0,554 22,40 1.268
3x50 0,386 26,00 1.799
3x70 0,272 30,60 2.499
3x95 0,206 34,00 3.321
3x185 0,106 42,00 6.085
4x1,5 13,30 10,00 129
4x2,5 7,98 11,10 195
4x4 4,95 11,70 265
4x6 3,30 13,10 360
4x10 1,91 15,70 552
4x16 1,21 17,90 789
4x25 0,78 22,50 1.216
4x35 0,554 24,60 1.642
4x50 0,386 29,20 2.305
4x70 0,272 33,90 3.229
4x95 0,206 38,10 4.284
4x120 0,161 43,50 5.396
4x150 0,129 48,80 6.732
4x185 0,106 54,00 8.157
4x240 0,0801 61,40 10.686
5x1,5 13,30 11,10 173
5x2,5 7,98 12,30 233
5x4 4,95 12,70 321
5x6 3,30 14,10 433
5x10 1,91 17,15 641
5x16 1,21 19,90 982
5x25 0,78 24,40 1.516
5x35 0,554 27,10 2.042
5x50 0,386 32,95 2.901
5x70 0,272 37,00 4.021
5x95 0,206 45,80 5.354
5x120 0,161 50,60 6.763
5x150 0,129 58,35 8.468
5x185 0,106 64,40 10.286
6x1,5 13,30 11,40 203
6x2,5 7,98 12,70 276
7x1,5 13,30 11,40 237
7x2,5 7,98 12,70 324
8x1,5 13,30 12,70 257
8x2,5 7,98 15,85 359
10x1,5 13,30 14,20 330
10x2,5 7,98 17,80 455
12x1,5 13,30 14,35 360
12x2,5 7,98 18,40 498
14x1,5 13,30 16,70 398
14x2,5 7,98 18,65 548
16x1,5 13,30 17,30 436
16x2,5 7,98 19,25 622
19x1,5 13,30 18,25 490
19x2,5 7,98 21,35 712
24x1,5 13,30 19,35 651
24x2,5 7,98 24,90 924
30x1,5 13,30 21,60 765
30x2,5 7,98 26,35 1.100
37x1,5 13,30 23,45 1.115
RC4Z1-K (AS) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Cables with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
114
www.cablesrct.com
90ºmax AS
RC4Z1-K mica (AS+) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
· ITC-BT 28 Public premises
In compliance with the Fire Safety Regulation in Industrial Establishments, 2004.
In compliance with core document SI Fire Safety Standards of Spanish Technical Building Code, March 2006., March 2006.
period of 90 minutes at 400 ºC.
Description
tection to avoid parasitic currents. Useful in applications for the control and command of inverters, solenoid valves, machine and logic controller start-up, power switches, temperature, current or voltage regulation in motorised valves as well as for installation in computing facilities, airports, road tunnels, railway networks and wherever a low emission of corrosive fumes and gases is required
1. Conductor Flexible electrolytic copper (Class V) in compliance with UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Mica tape
3. Insulation Cross-linked polyethylene (XLPE), type DIX 3 in compliance with UNE 21123 and HD 603S1
4. Shield 70% copper braid on polyester sheet
5. Casingreduced emission of fumes and reduced opacity
Nominal voltage 0.6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours in compliance with UNE 21089 and HD 308S2
· Fire resistant in compliance with UNE-EN 50200, EN 50200, UNE-EN 50362 and EN 50362
· Low halogen content in compliance with UNE-EN 50267 and EN 50267
· Low emission of corrosive gases in compliance with UNE-EN 50267 and EN 50267
· Low emission of opaque fumes in compliance with UNE-EN 61034, EN 61034 and IEC 61034
115
www.cablesrct.com
1x1,5 13,30 7,49 70
1x2,5 7,98 8,04 84
1x4 4,95 8,74 104
1x6 3,30 9,46 132
1x10 1,91 11,90 231
1x16 1,21 13,10 300
1x25 0,780 14,20 389
1x35 0,554 15,30 489
1x50 0,386 16,80 637
1x70 0,272 18,70 835
1x95 0,206 21,10 1.098
1x120 0,161 22,60 1.331
1x150 0,129 24,70 1.628
1x185 0,106 26,90 1.975
1x240 0,0801 30,00 2.514
1x300 0,0641 33,20 3.114
1x400 0,0486 40,80 4.600
2x1,5 13,30 9,00 96
2x2,5 7,98 9,90 122
2x4 4,95 10,70 156
2x6 3,30 11,80 202
2x10 1,91 13,80 296
2x16 1,21 16,30 436
2x25 0,780 19,50 646
3x1,5 13,30 9,60 117
3x2,5 7,98 11,20 172
3x4 4,95 12,00 216
3x6 3,30 13,40 286
3x10 1,91 15,70 422
3x16 1,21 17,60 594
3x25 0,780 21,20 872
3x35 0,554 24,40 1.195
4x1,5 13,30 10,30 141
4x2,5 7,98 11,20 183
4x4 4,95 13,10 275
4x6 3,30 14,80 355
4x10 1,91 17,10 529
4x16 1,21 19,50 755
4x25 0,780 22,50 1.079
4x35 0,554 25,70 1.506
4x50 0,386 30,10 2.037
4x70 0,272 35,00 2.804
4x95 0,206 40,20 3.741
5x1,5 13,30 11,20 167
5x2,5 7,98 12,70 233
5x4 4,95 14,00 310
5x6 3,30 16,00 431
5x10 1,91 18,10 619
5x16 1,21 21,50 928
5x25 0,780 25,70 1.387
5x35 0,554 29,80 1.905
RC4Z1-K mica (AS+) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
116
www.cablesrct.com
90ºmax AS
RZ1C4Z1-K mica (AS+) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications
· ITC-BT 28 Public premises
In compliance with the Fire Safety Regulation in Industrial Establishments, 2004.
In compliance with core document SI Fire Safety Standards of Spanish Technical Building Code, March 2006., March 2006.
period of 90 minutes at 400 ºC.
Description
protection to avoid parasitic currents. Useful in applications for the control and command of inverters, solenoid valves, machine and logic controller start-up, power switches, temperature, current or voltage regulation in motorised valves as well as for installation in computing facilities, airports, road tunnels, railway networks and wherever a low emission of corrosive fumes and gases is required
1. Conductor Flexible electrolytic copper (Class V) in compliance with UNE-EN 60228, EN 60228 and IEC 60228
2. Insulation Mica tape
3. Insulation Cross-linked polyethylene (XLPE), type DIX 3 in compliance with UNE 21123 and HD 603S1
4. Shield cover
5. Shield 70% copper braid on polyester sheet
6. Casingreduced emission of fumes and reduced opacity
Nominal voltage 0.6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours in compliance with UNE 21089 and HD 308S2
· Fire resistant in compliance with UNE-EN 50200, EN 50200, UNE-EN 50362 and EN 50362
·
·
· Low halogen content in compliance with UNE-EN 50267 and EN 50267
· Low emission of corrosive gases in compliance with UNE-EN 50267 and EN 50267
· Low emission of opaque fumes in compliance with UNE-EN 61034, EN 61034 and IEC 61034
117
www.cablesrct.com
1x6 3,30 12,50 147
1x10 1,91 13,30 198
1x16 1,21 14,50 260
1x25 0,78 16,00 365
1x35 0,554 16,80 474
1x50 0,386 19,00 635
1x70 0,272 20,80 854
1x95 0,206 23,50 1.089
1x120 0,161 25,50 1.364
1x150 0,129 28,00 1.673
1x185 0,106 31,00 2.026
1x240 0,0801 33,00 2.567
1x300 0,0641 35,00 3.172
2x1,5 13,30 13,00 185
2x2,5 7,98 14,00 276
2x4 4,95 15,00 336
2x6 3,30 16,00 412
2x10 1,91 19,00 580
2x16 1,21 21,00 763
2x25 0,78 24,50 1.079
3x1,5 13,30 13,50 200
3x2,5 7,98 14,50 289
3x4 4,95 15,50 372
3x6 3,30 17,00 462
3x10 1,91 19,50 661
3x16 1,21 22,00 885
3x25 0,78 26,00 1.281
4x1,5 13,30 16,00 215
4x2,5 7,98 17,00 351
4x4 4,95 19,00 438
4x6 3,30 20,50 557
4x10 1,91 23,50 794
4x16 1,21 26,00 1.172
4x25 0,78 30,00 1.583
4x35 0,554 31,50 1.995
4x50 0,386 36,00 2.785
4x70 0,272 34,90 3.860
4x95 0,206 39,10 5.148
4x120 0,161 44,50 6.387
5x1,5 13,30 11,30 271
5x2,5 7,98 12,40 411
5x4 4,95 13,70 517
5x6 3,30 15,10 660
5x10 1,91 18,15 950
5x16 1,21 20,90 1.297
5x25 0,78 25,40 1.969
5x35 0,554 28,10 2.456
RZ1C4Z1-K mica (AS+) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
118
www.cablesrct.com
RVKV-K 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Applications · Underground networks for low voltage distribution
· Underground supply networks for outdoor lighting installations
· Electricity distribution networks. Underground service connections
· Indoor or receiver installations
· Installations in premises with special characteristics
Description
These cables are indicated for executing permanent installations where electromagnet protection is required to avoid parasitic cu-rrents. Their use is recommended in control applications of drivers, solenoid valves, start-up of machines and robots, remote switches,
Technical Characteristics1. Conductor Flexible electrolytic copper, (Class V), according to BS EN 60228:2005 (previously BS6360) and
UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE21123 and HD 603S1
3. Bedding PVC
4. Concentric conductor Outer conductor of copper wires and contrahelical copper wires
5. Sheathing PVC sheath type ST-1, according to UNE 21123 and IEC 60502-1
Rated voltage 0,6/1kV
Test voltage 3.500V in A.C.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
· PVC sheath with reduced hydrogen chloride (HCL) emission
· The use of XLPE admits greater current density, at equal section, respect to the insulation with PVC
119
www.cablesrct.comRVKV-K 0,6/1kV
1x150 0,129 25,55 1.671
1x185 0,106 27,80 2.008
1x240 0,0801 31,40 2.691
1x300 0,0641 33,00 3.161
3x1,5/1,5 13,30 12,90 195
3x2,5/2,5 7,98 13,25 229
3x4/4 4,95 14,60 304
3x6/6 3,30 15,95 398
3x10/10 1,91 18,25 576
3x16/16 1,21 21,05 842
3x25/25 0,78 24,40 1.223
3x35/35 0,554 26,90 1.601
3x50/50 0,386 30,80 2.229
3x70/70 0,272 35,40 3.081
3x95/95 0,206 38,10 3.935
3x120/120 0,161 44,60 5.077
3x150/150 0,129 51,20 6.396
3x185/185 0,106 56,00 7.334
3x240/240 0,0801 61,30 10.077
4x2,5/2,5 7,98 14,40 276
4x4/4 4,95 15,80 356
4x6/6 3,30 17,25 470
4x10/10 1,91 20,10 699
4x16/16 1,21 22,90 959
4x25/25 0,78 27,20 1.463
4x35/35 0,554 29,50 1.965
4x50/50 0,386 31,05 2.745
4x70/70 0,272 39,35 3.816
4x95/95 0,206 42,80 4.915
4x120/120 0,161 50,25 6.352
4x150/150 0,129 57,40 7.955
4x185/185 0,106 62,90 9.646
4x240/240 0,0801 67,30 12.313
3x25/16 0,78 24,40 1.153
3x35/16 0,554 26,90 1.451
3x50/25 0,386 30,20 2.137
3x70/35 0,272 37,75 2.981
3x95/50 0,206 41,45 3.863
3x120/70 0,161 45,30 4.912
3x150/70 0,129 53,60 5.922
3x185/95 0,106 55,10 7.261
3x240/120 0,0801 60,65 9.412
4x25/16 0,78 25,60 1.395
4x35/16 0,554 28,85 1.826
4x50/25 0,386 32,85 2.615
4x70/35 0,272 38,30 3.633
4x95/50 0,206 42,45 4.717
4x120/70 0,161 46,80 6.022
4x150/70 0,129 52,10 7.249
4x185/120 0,106 57,30 8.925
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Cables of more of 4 conductors can be produced on demand.The concentric outer conductor works as screen and earth.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Section(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
120
www.cablesrct.com
RZ1KZ1-K (AS) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
Description These cables are indicated for executing permanent installations where electromagnetic protection is required to avoid parasitic cur-rents. Their use is recommended in control applications of drivers, solenoid valves, start-up of machines and robots, remote switches, temperature, intensity or voltage regulation in motorised valves as well as for installations in computer centres, airports, road tunnels,
schools and shopping centres.
Technical characteristics1. Conductor Flexible electrolytic copper (Class V), according to BS EN 60228:2005 (previously BS6360) and
UNE 60228
2. Insulation Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE21123 and HD 603S1
3. Bedding HFFR compound
4. Concentric conductor Outer conductor of copper wires and contrahelical copper wires
5. Sheathing
Rated voltage 0,6/1kV
Test voltage 3.500V in C.A.
Maximum temperature 90 ºC
Other characteristics
· Colours according to UNE 21089 and HD 303S2:2001
·
·
· Low halogen content according to UNE-EN 50267, EN 50267 and IEC 60754
· Low corrosive gas emission according to UNE-EN 50267, EN 50267 and IEC 60754
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
· The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC
Applications
· Underground supply networks for outdoor lighting installations
· Underground networks for low voltage distribution
· Electricity distribution networks. Underground service connections
· Installations in premises with special characteristics
121
www.cablesrct.com
1x120 0,161 23,85 1.407
1x150 0,129 25,85 1.706
1x185 0,106 28,00 2.044
1x240 0,0801 31,40 2.626
1x300 0,0641 33,70 3.200
3x1,5/1,5 13,30 12,20 186
3x2,5/2,5 7,98 12,90 229
3x4/4 4,95 14,45 303
3x6/6 3,30 15,75 395
3x10/10 1,91 18,10 576
3x16/16 1,21 20,40 820
3x25/25 0,78 24,30 1.234
3x35/35 0,554 26,40 1.611
3x50/50 0,386 31,80 2.331
3x70/70 0,272 35,60 3.230
3x95/95 0,206 41,10 4.232
3x120/120 0,161 48,90 5.150
3x150/150 0,129 50,50 6.602
3x185/185 0,106 54,80 8.009
3x240/240 0,0801 60,70 10.564
4x1,5/1,5 0 13,00 214
4x2,5/2,5 7,98 14,20 273
4x4/4 4,95 15,85 359
4x6/6 3,30 17,45 478
4x10/10 1,91 20,35 714
4x16/16 1,21 22,25 983
4x25/25 0,78 26,85 1.473
4x35/35 0,554 29,60 1.970
4x50/50 0,386 34,45 2.823
4x70/70 0,272 40,20 3.928
4x95/95 0,206 45,25 5.101
4x120/120 0,161 50,95 6.518
4x150/150 0,129 55,70 8.011
4x185/185 0,106 61,60 9.687
4x240/240 0,0801 69,35 12.832
RZ1KZ1-K (AS) 0,6/1kV
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Instrumentation and control
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
122
www.cablesrct.com
6 3,06 2,95 50,50
10 1,83 3,72 85,30
16 1,15 4,60 136,40
25 0,727 6,30 215
35 0,524 7,55 291
50 0,387 8,15 404
70 0,268 10,10 595
95 0,193 11,90 827
120 0,153 13,10 1.050
150 0,124 14,74 1.265
185 0,0991 16,60 1.619
240 0,0754 18,75 2.090
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Rigid bare copperBare copper
Applications
· Earthing installations
Description These bare copper cables are indicated for executing earthing installations of electrical devices in both domestic and industrial installations.
Technical characteristics1. Conductor Electrolytic Rigid Bare (Clase II), according to BS EN 60228:2005 (previously BS 6360) and UNE 60228
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
The weights shown in this table are only indications and are meant for the sole purpose of comparison. These cables are to be sold by length.
123
www.cablesrct.com
16 1,21 5,00 125,75
25 0,780 6,25 195
35 0,554 7,30 275
50 0,386 8,80 394
70 0,272 10,50 561
95 0,206 11,95 744
120 0,161 13,60 950
150 0,129 15,25 1.188
185 0,106 17,00 1.454
240 0,0801 19,50 1.915
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Bare copper
Flexible bare copper
Applications
· Earthing installations
Description These bare copper cables are indicated for executing earthing installations of electrical devices in both domestic and industrial installations
Technical characteristics
1. ConductorUNE 60228
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
The weights shown in this table are only indications and are meant for the sole purpose of comparison. These cables are to be sold by length.
124
www.cablesrct.com
H07V-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Prewired tube
Applications
· Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
·
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description
well as domestic and industrial lighting. Electrical conductors of different colours and sections required to execute each installation are inserted onto the inside of a corrugated tube, thus achieving a product that provides the installer with an integral service that has numerous advantages and also saves time and costs.
Technical characteristics1. Conductor Electrolytic copper conductor (Class I and II), according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation PVC insulation, type TI-1, according to BS 21031-3 and HD 21.3S3: 1995/12:2008
3. Tube Fireproof polypropylene corrugated tube with low halogen content, low fumes emission and
properties (750N)
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
125
www.cablesrct.com
2x1,5 16,00 12,10 25
3x1,5 16,00 12,10 38
2x1,5 20,00 12,10 25
2x2,5 20,00 7,41 42
3x1,5 20,00 12,10 38
3x2,5 20,00 7,41 62
3x4 20,00 4,61 101
4x1,5 20,00 12,10 51
4x2,5 20,00 7,41 83
5x1,5 20,00 12,10 64
3x2,5 25,00 7,41 62
3x4 25,00 4,61 101
3x6 25,00 3,08 153
4x4 25,00 4,61 135
4x6 25,00 3,08 204
5x2,5 25,00 7,41 104
5x4 25,00 4,61 169
5x6 25,00 3,08 255
6x2,5 25,00 7,41 125
7x1,5 25,00 12,10 89
7x2,5 25,00 7,41 146
H07V-U
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Prewired tube
Coils with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
126
www.cablesrct.com
H07V-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Prewired tube
Applications
· Outdoor lighting installations. Earthing
· Indoor or receiver installations
· Indoor installations in housing
· Premises that contain a bath or shower
·
· Installations in premises with special characteristics
· Electrical installations in caravans and in caravans parks
Description
well as domestic and industrial lighting. Electrical conductors of different colours and sections required to execute each installation are inserted onto the inside of a corrugated tube, thus achieving a product that provides the installer with an integral service that has numerous advantages and also saves time and costs.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation PVC insulation, type TI-1, according to UNE 21031-3 and HD 21.3S3: 1995/12:2008
3. Tube Fireproof polypropylene corrugated tube with low halogen content, low fumes emissions and
properties (750N)
Rated voltage 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
· PVC insulation with reduced hydrogen chloride (HCL) emission
127
www.cablesrct.com
2x1,5 13,30 16,00 87
2x2,5 7,98 16,00 108
3x1,5 13,30 16,00 105
4x1,5 13,30 16,00 124
3x1,5 13,30 20,00 125
3x2,5 7,98 20,00 1.418
3x4 4,95 20,00 198
4x1,5 13,30 20,00 144
4x2,5 7,98 20,00 187
5x1,5 13,30 20,00 163
5x2,5 7,98 20,00 217
6x1,5 13,30 20,00 182
7x1,5 13,30 20,00 201
8x1,5 13,30 20,00 219
3x2,5 7,98 25,00 203
3x4 4,95 25,00 243
3x6 3,30 25,00 297
5x6 3,30 25,00 419
7x1,5 13,30 25,00 246
H07V-K
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Prewired tube
Coils with more than 3 conductors can be manufacturedwith one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
128
www.cablesrct.com
H07Z1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Prewired tube
Applications
· Individual by-pass· Indoor or receiver installations· Public premises·
Description These cables are indicated for executing permanent installations where low fumes and corrosive gas emission is required in the
sections required to execute each installation are inserted onto the inside of a corrugated tube, thus achieving a product that provides the installer with an integral service that has numerous advantages and also saves time and costs.
Technical characteristics1. Conductor Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS
6360) and UNE 60228
2. Insulation
gases
3. Tube
properties (750N)
Rated voltgae 450/750V
Test voltage 2.500V in A.C.
Maximum temperature 70 ºC
Other characteristics
· Colours according to UNE 21031 and HD 21.1S4:2002
·
·
· Low halogen content according to UNE 211002 Appendix A and HD 21.15S1:2006
· Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
· Low corrosive gas emission according to UNE 211002 Appendix A and HD 21.1S1:2006
129
www.cablesrct.com
2x1,5 13,30 16,00 85
3x1,5 13,30 16,00 104
2x1,5 13,30 20,00 105
2x2,5 7,98 20,00 127
3x1,5 13,30 20,00 123
3x2,5 7,98 20,00 156
3x4 4,95 20,00 194
4x1,5 13,30 20,00 142
4x2,5 7,98 20,00 186
5x1,5 13,30 20,00 160
5x2,5 7,98 20,00 215
2x1,5 + 3x2,5 13,30/7,98 20,00 188
3x6 3,30 25,00 295
3x10+1,5 1,91/13,30 25,00 464
3x16+1,5 1,21/13,30 25,00 602
5x6 3,30 25,00 416
6x2,5 7,98 25,00 289
3x2,5 + 3x6 7,98/3,30 25,00 384
7x1,5 13,30 25,00 242
7x2,5 7,98 25,00 319
5x1,5+2x2,5 13,30/7,98 25,00 264
4x1,5+3x2,5 13,30/7,98 25,00 246
H07Z1-K (AS)
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Prewired tube
Coils with more than 3 conductors can be manufactured with one of the cores yellow/green.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
130
www.cablesrct.com
1x0,35 54,40 1,60 5,00
1x0,5 38,20 1,90 7,60
1x0,75 25,40 2,10 10,00
1x1 19,10 2,30 13,00
1x1,5 13,00 2,60 18,00
1x2 9,42 2,80 23,00
1x2,5 7,82 3,00 27,00
1x3 6,00 3,40 34,00
1x4 4,71 3,80 43,00
1x5 3,94 4,20 53,00
1x6 3,14 4,50 63,00
FLRY-B 105º
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
DimensionsSection(mm2)
Resistance at 20 ºC
Externaldiameter
(mm)
Weight(Kg/Km)
Description The FLRY-B 105º cables are indicated for the wiring road-trans-
copper composition makes them especially easy to handle.
· ·
Technical characteristics1. Conductor Flexible Cu-ETP-1-type electrolytic copper in compliance with DIN EN 13602
2. Isolation Reduced thickness PVC in compliance with ISO 6722
Nominal voltage 60V
Test voltage <0.5mm2 2 5.000V
Operating temperature - 40 ºC to 105 ºC
Automotive cables
131
www.cablesrct.com
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Voltages 300/500 and 450/750
Cables for permanent installations (UNE 21031 - UNE 21027)
Exterior diameter of the cables (mm)
D < 8 8 < D < 12 12 < D < 20
Normal use 4D 5D 6D 6D
Carefully curved 2D 3D 4D 4D
Cables for mobile installations (UNE 21031)
Exterior diameter of the cables (mm)
D < 8 8 < D < 12 12 < D < 20
Permanent installation 3D 3D 4D 4D
Free moving 5D 5D 6D 6D
At the entry of a device or mobile equipment with no mechanical stress on the cable
5D 5D 6D 6D
With mechanical stress (1) 9D 9D 9D 10D
In festoon, as in gantry cranes 10D 10D 11D 12D
Repeated coiling (1) 7D 7D 8D 8D
Diverted by pulleys (1) 10D 10D 10D 10D
Voltage 0.6/1 kV
Exterior diameter of the cables (mm)
D < 25 25 < D < 50
Non reinforced cables 4D 5D 6D
Exterior diameter of the cables (mm)
D < 25 25 < D < 50
Reinforced cables 10D 10D 10D
Cables for every day, cables for all your life.www.cablesrct.com
Curvature radiiVoltages 300/500, 450/700 y 0,6/1 kVA curved radius is the minimum torsion that a cable can support.
dynamic value (when it is being stretched) is always greater.
132
www.cablesrct.com
D
C
600 mm
125 mm
800 mm
A
B
80
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Reels A B C D Volume Palette
400L 400 mm 160 mm 250 mm 6 mm 23 dm3 No
500L 500 mm 160 mm 365 mm 8 mm 58 dm3 No
600L 600 mm 160 mm 466 mm 12 mm 113 dm3 No
800L 800 mm 315 mm 463 mm 13,5 mm 174 dm3 Yes
Packaging typesPlywood Reels
Packaging
Cables RCT offers its customers different packaging alternatives for its products, depending on their needs and the characteristics of each product. Apart from the traditional wooden reels for large-diameter cables, we also have plastic reels, especially adapted for repeated use and in more aggressive environments, such as on a construction site.
For small-diameter cables, we can individually prepare stretch-wrapped rolls of different metre lengths, starting at 50m for consumers concerned with comfort and ease of use and ending with 2000m rolls, in high demand by large cable consumers and users in workshop.
with the generalised use of barcodes.
133
www.cablesrct.com
A
B
B
A
80
C
C
D
D
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Wood A B C D Weight
630 630 mm 315 mm 370 mm 40 mm 17 Kg
800 800 mm 400 mm 520 mm 40 mm 30 Kg
1.000 1.000 mm 500 mm 610 mm 50 mm 56 Kg
1.250 1.250 mm 630 mm 710 mm 50 mm 85 Kg
1.400 1.400 mm 710 mm 810 mm 60 mm 150 Kg
1.600 1.600 mm 900 mm 980 mm 60 mm 225 Kg
B-500 A B C D Weight
500 500 mm 200 mm 300 mm 20 mm 5 Kg
Packaging typesReels
134
www.cablesrct.com
76
A
B
255 mm 255 mm
h
800 mm 1200 mm
h
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Packaging typesCardboard Reels
A B
165x100 165 100
165x150 165 150
200x100 200 100
200x150 200 150
225x100 225 100
225x150 225 100
250x150 250 150
300x150 300 150
325x150 325 150
365x150 365 150
380x150 380 150
The dimensions of the reels are nominal
Section mm2
h 0.50 0.75 1 1.5 2.5 4 6
40 mm 200 m 100 m 100 m
55 mm 200 m 200 m 100 m
67 mm 200 m 100 m
86 mm 100 m
Section mm2
h 1 1.5 2.5 4 6
960 mm 24.000 m 12.000 m
1.000 mm 36.000 m 18.000 m 14.400 m
135
www.cablesrct.com
400 mm
500 mm
400 mm
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Packaging typesBoxed Wire®
What capacity does it hold?
H05V-U H05V-K H05Z1-K (AS) H05V2-U H05V2-K H07V-U H07V-K H07Z1-U (AS) H07Z1-K (AS)
Section Meters
0,5 4.0000,75 3.000
1 2.5001,5 2.0002,5 1.3004 9006 600
What is Boxed Wire®?It is a new method for packaging cables specifically designed for large-scale consumers.
What does it consist of?The principle behind Boxed Wire® is very straightforward. The cable is placed in a cardboard box from where it can simply be pulled out, without the need for any implements or tools.
What are the dimensions of Boxed Wire®?A base of 400 X 400 mm and a height of 500 mm.
What are its advantages over a roll?The main advantage is that it provides the large-scale user a greater length of cable, thus resulting in fewer and shorter stops in production processes and a notable reduction in scrap.
What are its advantages over a coil?The main advantage is that it is easier to handle. No special tool or implement is required as the cable is simply and easily pulled out of the box. Moreover, as it can be palletised, it can be stored on a traditional shelf which, when compared to the greater costs of a coil-holder, represents a significant saving.
How much does it cost?The cost of this packaging is included in the cost of the cable.
Do we have to return the empty box?No. However, we would be very pleased to receive free of charge the empty boxes to manage their later treatment.
What types of cable can be packaged in Boxed Wire®?Boxed Wire® is specifically designed for packaging single-core cable, with sections between 0.5 mm2 and 6 mm2.
Can the quantities per box differ from the standard?Yes. Although the quantities given are those we deem most ad-equate for each cable, we can adjust to specific needs as and when they present themselves.
And if I need a greater quantity than that provided in one box, is there an alternative?Yes. Boxed Wire® allows for continuous manufacturing such that the cable can be supplied in groups of six boxes, in one single run, without any cut.
How is it handled?Handling Boxed Wire® is one of its great advantages. Each box can be used individually. To extract the cable, simply pull on it – there is no need for any extra equipment or tools. In addition, their dimensions have been studied so they fit on a Euro-pallet, making it especially easy to store. It is also possible to stack full pallets, which results in space saving and a significant improve-ment in logistics in comparison with other packaging methods.
FLRY-B
Section Meters
0,35 5.0000,5 4.0000,75 3.000
1 2.5001,5 2.0002 2.000
2,5 1.3003 1.3004 9005 6006 600
136
www.cablesrct.com
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Cable typeMeters per coil
25m 50m 100m 200m 300m 400m 500m 600m 700m 800m 900m 1.000m 1.500m
H07V-U
1,5 Stock Stock 5km Stock 5km 5km 5km 5km 5km 5km 5km
2,5 5km Stock Stock Stock 5km 5km 5km 5km 5km 5km 5km
4 3km Stock 3km 3km 3km 3km 3km 3km 3km 3km
H07V-R
6 3km 3km Stock 3km 3km 3km 3km 3km 3km 3km
10 2km 2km Stock 2km 2km 2km
16 2km 2km Stock 2km 2km
25 2km 2km 2km 2km
H05V-KH05Z1-KES05Z1-K (AS)
0,50 5km Stock 5km 5km 5km 5km 5km
0,75 5km Stock 5km 5km 5km 5km
1 5km Stock 5km 5km 5km
H07V-KH07Z1-K (AS)
1,5 Stock Stock 5km 5km 5km 5km 5km 5km 5km 5km 6km
2,5 5km Stock Stock 5km 5km 5km 5km 5km 5km 5km
4 3km Stock 3km 3km 3km 3km 3km 3km 3km 3km
6 3km 3km Stock 3km 3km 3km 3km 3km 3km 3km
10 3km 2km Stock 2km 2km 2km
16 2km 2km Stock 2km 2km
25 2km 2km Stock 2km
35 2km 1km Stock
500V
2x1 3km 3km Stock 3km 3km 3km 3km 3km 3km 3km
3x1 3km 3km Stock 3km 3km 3km 3km 3km 3km
4x1 3km 3km Stock 3km 3km 3km 3km 3km
5x1 3km 2km Stock 2km 2km 2km
TRIFIL®TRIFIL ® (AS)
3x1,5 3km 3km Stock 5km 5km 5km 5km 5km
3x2,5 Stock 5km 5km 5km
Cable typeMeters per coil
25m 50m 100m 150m 200m 250m 300m 350m 400m 450m
RV-KRZ1-K (AS)
2x1,5 2km
Stock Stock 2km
2km
2km
2km
2km
2km
2km
3x1,5 2km
Stock Stock 2km
2km
2km
2km
2km
2km
4x1,5 2km
Stock Stock 2km
2km
2km
2km
5x1,5 2km
Stock Stock 2km
2km
2km
2x2,5 2km
Stock Stock 2km
2km
2km
2km
2km
3x2,5 2km
Stock Stock 2km
2km
2km
2km
4x2,5 2km
Stock Stock 2km
2km
2km
5x2,5 2km
Stock Stock 2km
2km
2x4 2km
Stock Stock 2km
2km
2km
2km
3x4 2km
Stock Stock 2km
2km
2km
4x4 1km
Stock Stock 1km
1km
5x4 1km
Stock Stock 1km
2x6 1km
Stock Stock 1km
1km
1km
3x6 1km
Stock Stock 1km
1km
4x6 1km
Stock Stock 1km
5x6 1km
Stock Stock
Coil sized D h
145 240 20-120
200 400 40-180
140 210-560 80-140
Minimum quantityen km km km km
en stock Stock Stock Stock
Weight per coil
<25 kg
d140
D 210
D 560
h 80h
140
d 200
D 400
h 18
0
h 40
d 145
D 240
h 20h
120
Coil dimension
Packaging typesPossible Coils
137
www.cablesrct.com
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
Standard palletized materials
Packaging typesPalettes
750VH05V-K / H07V-U / H07V-R / H07V-K / ES05Z1-K (AS)H07Z1-K (AS) / H07Z-R
Section Metersroll
Rollgrouping
Metersgrouping
Palletsmeters
0,5 200 1 200 45.000
0,75 100 1 200 45.000
0,75 200 1 200 45.000
1 100 5 500 45.000
1 200 5 1.000 45.000
1,5 100 5 500 37.500
1,5 200 4 800 36.000
2,5 100 5 500 22.500
2,5 200 3 600 27.000
4 100 4 400 18.000
6 100 3 300 13.500
10 100 1 100 9.000
16 100 1 100 6.000
1000VRV-K / RZ1-K (AS)
Section Metersroll
Palletsmeters
2x1 50 ó 100 9.600
2x1,5 50 ó 100 6.000
2x2,5 50 ó 100 4.800
2x4 50 ó 100 4.200
2x6 50 ó 100 3.600
3G1 50 ó 100 8.400
3G1,5 50 ó 100 5.400
3G2,5 50 ó 100 4.800
3G4 50 ó 100 3.600
3G6 50 ó 100 2.400
4G1 50 ó 100 7.200
4G1,5 50 ó 100 4.800
4G2,5 50 ó 100 4.200
4G4 50 ó 100 3.000
4G6 50 ó 100 1.800
5G1 50 ó 100 5.400
5G1,5 50 ó 100 4.200
5G2,5 50 ó 100 3.000
5G4 50 ó 100 1.200
5G6 50 ó 100 1.200
138
www.cablesrct.comwww.cablesrct.com
ZARAGOZA [email protected]
BARCELONA [email protected]
MADRID [email protected]
SEVILLA [email protected]
VALENCIA [email protected]
The
info
rmat
ion
cont
aine
d on
this
pag
e is
for
info
rmat
ion
only
and
doe
s no
t con
stitu
te a
con
trac
tual
com
mitm
ent o
f any
kin
d fr
om C
able
s R
CT.
BARCELONA WAREHOUSECables RCT Barcelona WarehousePol Ind MonsolísAvinguda del Bon Pastor 19-2708930 Sant Adrià de BesòsBarcelona - Spaintelephone +34 93 3079562fax +34 93 3073400e-mail [email protected]
MADRID WAREHOUSECables RCT Madrid WarehouseArea Empresarial AndalucíaAvda. Río Guadalquivir, 728906 GetafeMadrid - Spaintelephone +34 91 6918548fax +34 91 2171735e-mail [email protected]
SEVILLA WAREHOUSECables RCT Sevilla WarehousePol Ind CalongeC/ Bronce Nave 441007 Sevilla - Spaintelephone +34 954 354946fax +34 954 358491e-mail [email protected]
VALENCIA WAREHOUSECables RCT Valencia WarehousePol Ind SedavíC/ Sequía de Calvera 5 A46910 Valencia - Spaintelephone +34 96 3759070fax +34 96 3758435e-mail [email protected]
ZARAGOZA HEADQUARTERCrta. Castellón Km 226,9 50720 La Cartuja BajaZaragoza - Spaintelephone +34 976 500120fax +34 976 500138e-mail [email protected]
Cables for every day,cables for all your life