15
Cabin Fans Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need. Part No. 6002 Standard Cabin Fan Dimensions: 10” Wide 6” High 6.75” Deep Power Requirement: .9 Amp @ 12 VDC True Output: 8700 BTU/h @ 110° F and 3.0 GPM Connections: 3/4” Hose Construction: Stainless Steel Case, Full Flow copper coil The 6002 Standard Cabin Fan is the basic unit that is used for several different fan applications. There are several faceplates available that allow ducted as well as direct flow installations. As with all ITR cabin fans, the core has low restrictions and can be used in multi-fan loops. Part No. 6093 High Output Cabin Fan Dimensions: 10” Wide 6” High 6.75” Deep Power Requirement: 1.6 Amp @ 12 VDC True Output: 12000 BTU/h @ 110° F and 3.0 GPM Connections: 3/4” Hose Construction: Stainless Steel Case, Full Flow copper coil The 6093 High Output Cabin Fan is ideal for applications that require high output and low power draw. It is typi- cally used to heat large areas and is usually ducted. Part No. 6048 Small Case Defroster Fan Dimensions: 10” Wide 6” High 6.75” Deep Power Requirement: 10.5 Amp @ 12 VDC on High True Output: 16000 BTU/h @ 110° F and 3.0 GPM on High Connections: 3/4” Hose Construction: Stainless Steel Case, Full Flow copper coil The 6048 cabin fan is typically used in applications that re- quire very high output and can be used as a small defroster fan. The fan is typically ducted. A 3-speed fan switch is available for this unit. 16

Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

  • Upload
    others

  • View
    17

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Cabin Fans

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 6002Standard Cabin Fan

Dimensions: 10” Wide ♦ 6” High ♦ 6.75” DeepPower Requirement: .9 Amp @ 12 VDCTrue Output: 8700 BTU/h @ 110° F and 3.0 GPMConnections: 3/4” HoseConstruction: Stainless Steel Case, Full Flow copper coil

The 6002 Standard Cabin Fan is the basic unit that is used for several different fan applications. There are several faceplates available that allow ducted as well as direct flow installations. As with all ITR cabin fans, the core has low restrictions and can be used in multi-fan loops.

Part No. 6093High Output Cabin FanDimensions: 10” Wide ♦ 6” High ♦ 6.75” DeepPower Requirement: 1.6 Amp @ 12 VDCTrue Output: 12000 BTU/h @ 110° F and 3.0 GPMConnections: 3/4” HoseConstruction: Stainless Steel Case, Full Flow copper coil

The 6093 High Output Cabin Fan is ideal for applications that require high output and low power draw. It is typi-cally used to heat large areas and is usually ducted.

Part No. 6048Small Case Defroster FanDimensions: 10” Wide ♦ 6” High ♦ 6.75” DeepPower Requirement: 10.5 Amp @ 12 VDC on HighTrue Output: 16000 BTU/h @ 110° F and 3.0 GPM on HighConnections: 3/4” HoseConstruction: Stainless Steel Case, Full Flow copper coil

The 6048 cabin fan is typically used in applications that re-quire very high output and can be used as a small defroster fan. The fan is typically ducted. A 3-speed fan switch is available for this unit.

16

Page 2: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Cabin FansPart No. 6094Low Profile Galvanized Cabin FanDimensions: 13.25” Wide ♦ 4.5” High ♦ 8.0” DeepPower Requirement: 1 amp @ 12 VDCTrue Output: 6000 BTU/h @ 110° F and 3.0 GPMConnections: ¾” HoseConstruction: Galvanized case, Tube and Fin copper core

The 6094 cabin fan is a low cost, compact and extreme-ly efficient cabin fan that is ideal for multi-fan series or manifold plumbed systems. With its dual brushless motor fans, it is quiet and the multi-pass core design has very low restriction. The mounting brackets are part of the case.

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 6095Small Space Galvanized Cabin FanDimensions: 9.0” Wide ♦ 5.5” High ♦ 5.75” DeepPower Requirement: .5 amp @ 12 VDCTrue Output: 4000 BTU/h @ 110° F and 3.0 GPMConnections: ¾” HoseConstruction: Galvanized Case, Tube and Fin copper core

The 6095 cabin fan is a low-cost solution for small space heating. The 6094 is ideal for small cabins and heads. A low-restriction multi-pass coil allows multiple units on a sin-gle loop. The fan is a low-amperage brushless motor. The mounting brackets are part of the case.

Part No. 6096Low Profile Dual Fan Defrost HeaterDimensions: 15.5” Wide ♦ 6.0” High ♦ 13.0” DeepPower Requirement: 9.8 Amps @ 12 VDC on High SettingTrue Output: 20000 BTU/h @ 110° F and 3.0 GPM Connections: ¾” HoseConstruction: Plastic Case, Tube and fin copper core

The 6069 Low profile defrost fan is designed as a high output solution for defroster and large space heating applications. The plastic case includes 4, 2.5” outlets that can be adapted to use 2” or 3” duct. In applications that require a single output point, the 4 ducts can be removed. The unit comes with SS mounting brackets. A 3-speed fan switch is available for this unit.

17

Page 3: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 1013Outlet Plate Double 4”/4”

Part No. 1056Outlet Plate Triple 3”/3”/3”

ITR makes a variety of outlet plates designed to fit the Standard Fan profile. The outlet plates are Stainless Steel with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple outlet configurations. See price list for additional information and part numbers.

Part No. 1017Air Vent Adjustable round 4” Blackor 1017W White

Part No. 1051Air Vent Adjustable round 3” Black

Part No. 60011Air Vent Adjustable round 2” Black

ITR stocks a variety of vent outlets from 2” to 4” in diameter that are compatible with virtually any type of vent ducting. Maximum temperature of air is 180° F.

No. 1048Face Plate Grill 6” X 9” Black Anodized

No. 1049Face Plate Grill 7” X 12” Black Anodized

No. 1057Face Plate Grill 4” X 12” Black Anodized

These grills are anodized aluminum and are designed to be surface mounted. They can be used with any of the ITR cabin fans. The 1057 grill is also available in a bare aluminum mill finish for coating to the customer requirements.

18

Accessories Cabin Accessories

Page 4: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

No. 16017Water Pump Johnson 3/4”

The Johnson 3/4” pump features a magnetically driven impeller and draws 2.1 Amps @ 12 VDC. It should only be used in smaller systems with less than 5 cabin fans and less than 100 feet of total hose run. It is an excellent choice as an engine pre-heat pump and because of its small size, an excellent choice for multi-pump manifold systems.

No. 16018Water Pump March 3/4” Plastic Head

The March 3/4” plastic head pump is our most popular model. It is a magnetic drive and draws 3.5 amps @ 12 VDC. This is the pump of choice for any series plumbed system with no more than 6 cabin fans and 150’ of 3/4 heater hose. The pump is extremely reliable and has replaceable brushes. This pump has been developed spe-cifically for ITR and is designed to operate without decou-pling within the heater voltage limits.

No. 16014Water Pump Johnson 1.5”

The Johnson 1.5” pump is the large system pump for series plumbed systems that are outside of the recom-mended limits or for large manifold systems. This pump is a seal-type pump and draws 7.4 amps @ 12 VDC.

19

Circulation Pumps

Page 5: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 16023Water Pump 3/4” or 1.5” Flange 115 VAC Taco

The Taco 16023 pump is a household type in-line cir-culator that can be used with ¾” or 1.5” lines. It is available with amp draws of .79 and 1.4 @ 115 VAC. These pumps are an excellent choice for systems where there is a reliable source of AC power. One of ITR’s dealers has developed an AC/DC pump system that allows the system to use either a DC or AC pump, automatically selecting the available voltage. See the parts list for part number and pricing for the AC/DC Pump Relay Box.

PUMP CHART

0

5

10

15

20

25

30

35

40

0 2 4 6 8 10 12

FLOW (GPM)

HEA

D IN

FT

MARCH 809-BR-HS-12

MARCH 809-BR-12

JOHNSONCM30 P7-1JOHNSON C090P5-1

TACO 008 .7 AMP

TACO 009 1.3 AMP

20

Circulation Pump & Pump Chart

Page 6: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No 20001Expansion Tank Horizontal 3/4”Connections

ITR makes a variety of Expansion Tanks. These are constructed of copper, in 4” and 6” diameters with 7.5 PSI pressure caps and mounting brackets. The 6” tanks can be ordered with ¾” or 1.5” connections. All systems should be designed to use the largest expansion tank possible. ITR also carries high quality plastic overflow bottles in 2 qt. and 4 qt. sizes

Part No. 200302 Quart Overflow Bottle

ITR carries two sizes of overflow bottle, the 2 quart model shown here and a 4 quart model. These are heavy-duty parts and are the only approved overflow bottle for ITR systems.

Part No. 2266.75” In-Line Air Bleeder

The in –line air bleeder is used facilitate removal of trapped air in the system. At least one bleeder should be used in each plumbing loop.

21

Plumbing

Page 7: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 5133Exhaust Pipe 1.5” Flexible

ITR offers flexible 316 Stainless Steel exhaust pipe in 1.5” and 2” ID. This is the easiest exhaust to install. It should be installed in such a way that yearly inspection is pos-sible.

Part No. 5130Heat Exchanger WP-1-20

ITR carries three very efficient flat plate SS heat exchang-ers that fit a variety of applications. The 5130 exchang-er has 20 plates and is extremely efficient at high heat loads. It is suitable for use as an engine heat exchanger or for on-demand hot water. Since the 5130 and 5132 heat exchangers are single wall when used for potable water support the system must be filled with non-toxic coolant (usually labeled “GRAS”). ITR offers a double-wall heat exchanger, P/N 5142, which can be used with toxic coolant types in domestic water applications.

Part No. 13008Muffler 1.5” SS

ITR’s unique burner technology allows the use of mufflers to further quiet the heater exhaust. These mufflers come in 1.5” and 2” diameters, in 12” and 18” lengths. They are made of Stainless Steel and are the only mufflers approved for use with ITR systems. ITR strongly encour-ages the use of the longest muffler compatible with the heater model.

22

Heat Exchangers & Exhaust Accessories

Page 8: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 5135Exhaust Heat Sleeve 1.5”

We have a variety of exhaust insulation materials, designed as socks or wraps and sized to fit the 1.5” and 2.0” exhaust pipe. ITR can also provide custom built exhaust cladding by special order.

Part No. 23221.5” Elbow with 2 Flanges SS

ITR provides several 2.0” and 2.5” radius exhaust elbows in 1.5” and 2” ID in Staiinless Steel and mild steel. They are available with no flange, one flange and 2 flanges. We also have sealant and T-bolt clamps to secure and seal the exhaust components.

Part No. 5158Combination Exhaust Through-hull 1.5”

ITR makes combination exhaust through-hulls in a number of configurations for both 1.5” and 2” exhausts. These units combine the 2” combustion air intake with the exhaust out-let. Care must be taken to use these fittings only if the fitting can be completely protected from water ingestion. The 1.5” fittings require a 3” mounting hole and the 2” fittings require a 3.5” mounting hole. They are made of 316 SS.

23

Exhaust Accessories

Page 9: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 5139Exhaust Through-Hull Plug 1.5” SS

The through hull plug is designed to be used for our com-bination exhaust fittings and should be included in every system kit. The combination exhaust fittings incorporate an intake and exhaust in the same fitting and are vulner-able to water ingestion in high sea conditions.

Part No. 20012 Standard Thermostat

This thermostat can be used for any system installation. The range is from 50° F to 90° F and can be turned off by moving the control lever all the way to the left. Available only in white.

Part No. 517315° Exhaust Only Through Hull

This item can be used for both power and sail applica-tions. In power applications, the angle of the through-hull allows a rise to be designed into the exhaust installation. In sail applications the exhaust can be mounted on a re-verse transom at a correct angle. The part is made of 316 SS and is available for 1.5” and 2” exhausts. Both sizes require a 2.5” mounting hole and come with gaskets for heat protection.

24

Exhaust & Thermostats

Page 10: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 20024Digital Zone Thermostat

This thermostat can be used for any system installation. The temperature control range is from 40° F to 90° F and can be set for Centigrade or Fahrenheit. It is powered by 2 included AA batteries and has numerous settings to match any installation requirements.

Part No. 2122LCD Remote Heater Control

This control is standard with the H2 and H2L heaters, optional with the SCH heater. It features an on/off switch for enabling the heater function and a scrolling LCD display that shows the heater status.

Part No. 2010LED Remote Heater Control

This control is standard with the SCH heater. It features an on/off switch for enabling the heater function and a single digit/symbol display that shows the heater status.

25

Thermostats & Switches

Page 11: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 5264Multi-Function Control Panel

This component features switches that control Cabin Fan speed, Domestic Water function and Engine Heat func-tion. It can be used with any ITR heating system.

Part No. 5309Hi/Low Fan Speed Switch

This switch allows speed control for up to three Cabin Fans (except the defroster fans). The high output fan requires a two fan speed switch. The switches also have an off position.

Part No. 53123-Speed Defroster Fan Switch

This switch is the speed control for the 3-speed defrost-er fans.

26

Switches

Page 12: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

27

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Maintenance Parts

Part No. 18001Fuel Regulator

This part is used in all ITR powered systems. It is not normally repairable and shoud be replaced if found to be defective.

Part No. 14017Fuel Nozzle

The fuel nozzle is sized specifically for the heater BTU output. Please refer to the price list for the part number of the nozzle required for your specific heater. ITR recommends a spare nozzle be included in the system parts kit.

Part No. 19059Fuel Solenoid

The fuel solenoid is used in all ITR powered systems.

Page 13: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Part No. 9002Igniter

The igniter is used in all ITR powered systems. ITR rec-ommends a spare igniter be included in the system parts kit.

Part No. 16015Fuel Pump

The ITR fuel pump is an electronic pump that is designed for continuous use. The pump is used in all ITR powered system and retrofit kits are available to replace the old style Walbro fuel pump with this more reliable model.

Part No. 6017Fuel Filter

The recommended filter has a 10 micron cartridge and is easily changed. The filter comes with a mounting bracket and hose barb fittings.

28

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Page 14: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

29

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.

Part No. 20106Digital Flame Sensor

The 20106 flames sensor is used in all ITR powered

heaters.

Part No. 2011V-2001 Digital Control Board

The 2001 board is the standard control board used in all current Hurricane heaters.

Part No. 3019Air Compressor SCH, H2, H2L, HWH

This is the standard compressor used in all ITR heaters. There are configuration changes specific to each heater model. Please consult the price list for application-specific part numbers.

Page 15: Cabin Fans - itrheat.comitrheat.com/wp-content/uploads/2017/01/ITRAccessoriesF.pdf · with plastic vent collars. The vent collars are available in 2”, 3” and 4” single and multiple

Part No. 45026Combusion Fan Assembly H2, H2L

The combustion fan assembly is used in all ITR powered heaters. There are configuration changes specific to each heater model. Please consult the price list for application-specific part numbers.

Part No. 2232Counterflow Tube

The combustion tube is constructed of 310 Hi-Temp Stainless Steel and is used through-out the ITR powered heater line.

30

Many of the parts in the parts and accessories section have several different configurations, the part shown is an example of the overall configuration. Please go to the price list for information on the other configurations available for the part you need.