BY PHIL RODIN Air and Water Chiller Basic Class

BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Embed Size (px)

Citation preview

Page 1: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

BY PHIL RODIN

Air and Water Chiller Basic Class

Page 2: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Things to check when chiller is not running or is in alarm

Page 3: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm showing water flow, pumps both chilled and condenser water types of flow switches

Page 4: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm showing water flow, pumps both chilled and condenser water types of flow switches

Page 5: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm showing water flow, pumps both chilled and condenser water types of paddle switches

Page 6: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm showing water flow, pumps both chilled and condenser water types of electronic flow switches

Electronic flow switches have probes

Page 7: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm Conditions

High Pressure1. Low water flow2. Cooling tower3. Strainers (locations?)4. Valves (electric or manual types)5. The entering and leaving water temp.6. Approach temp

Page 8: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm conditions

Page 9: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm conditions

Page 10: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm conditions

Page 11: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm conditionsChilled water flow

1. Pumps2. Strainers3. Valves (manual and electric)4. Flow switches5. Water temp in and out6. Approach temp

Page 12: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Alarm conditionsChilled water flow (cont.)

PRV

Page 13: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

What is the oil temperature?

1. Feel the tank or read with inferred.2. Check control panel3. Check for power4. Think out of the box, How can we heat

this?

Page 14: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

What is the oil temperature?(cont.)

Page 15: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

What is the oil temperature?(cont.)

Page 16: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Pressure & Temp. Gauges(electronic)

Page 17: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Pressure & Temp. Gauges(fluid type)

Page 18: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Surging

ASK YOURSELF?????1. Is it a high or low end surge?2. Are your amps going up or down?3. The sound? a. Is it an elephant b. Is it a grumble

Page 19: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Surging(High & Low Surging)

High Surge on Low Pressure Machines1. Water temp. in and out.2. Approach 3. Cooling Tower4. Purge5. Refrigerant levels

Page 20: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Surging(High & Low Surging)

Page 21: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Surging(High & Low Surging)

Page 22: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Surging(High & Low Surging)

Page 23: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Surging(High & Low Surging)

Page 24: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Surging(capacity control)

Page 25: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Chiller Capacity Control

Page 26: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Low End Surge

1. Water temp. In and out2. Approach Temp.3. Water pressure4. Refrigerant levels

Page 27: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Low End Surge

Page 28: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Low End Surge

Page 29: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Transducers & Sensors Types

Page 30: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Transducers & Sensors Types

Page 31: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Panel Codes

1. Carrier code 11112. York code 9675 aka YORK3. Trane code ++--++ (different

combinations)

Page 32: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

How’s the Chiller Running?

Is the chiller running in local?Is the chiller running in EMS?Are the pumps running?Are the valves open?Hand –off Auto (Think before going to hand)

Page 33: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Cavitation of Pumps

1. Strainers2. Water pressures3. Couplings4. Valves5. Primary or Secondary Loop

Page 34: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm

Questions(There is no such thing as a dumb question)

?

Page 35: BY PHIL RODIN Air and Water Chiller Basic Class. Things to check when chiller is not running or is in alarm