BurnIt
Citation preview
Ribbed chamber surface and three-pass fluegas flow for improved heat exchange
Steel boiler with intelligent controller and electric fan for forced airfeed. Wood-fired boilers WB-S Active range in nominal output from20 to 110 kW to satisfy the heating demands of medium to large sizedspaces. They are engineered for burning solid fuel and provide theoption for fitting pellet, oil or gas-fired burners.
Wood-fired boilerBURNiT WB-S Active
Product Features
Combustion chamber with large heat exchangingsurface and low chamber resistance
Large firebox door ensures easy loading evenwith bigger wood chunks
Burner flange on lower door for fitting gas, oil,or pellet burners
Safety devices :1) Pressure relief valve 2,5 bar incl.in the delivery set2) Safety heat evacuator a tap-water-filled line passesthrough the upmost part of the boiler body. In case ofoverheating it is triggered open by a thermostatic valve(not included) to evacuate the heat off the boiler.
Exchangeable metallic ash grate protects thechamber base from the flame
by SUNSYSTEM
Electronic control unit controls the combustionby modulating the fan speed. Optional control ofcirculation pumps for DHW and central heating.
Electric fan for forced air feed optimizes thecombustion and the fuel consumption rate
Microprocessorcontrol unit
Mineral woolinsulation
Upper door
Safety heat evacuator
Watermantle
Burner flange
Exchangeable ash grate
Rock woolinsulation
Lower door
Drain
Air ventingarrangement
Cold waterinlet
Inspectionopening
Chimney
Hot water outlet
Sensor
Safety heatevacuatorinlet/outlet
Design complying with EN 303-5
Required chimney draftPa
mbar 0.16 0.20 0.21 0.23 0.24 0.38 0.47 0.56
16 20 21 23 24 38 47 56
Technical specification:
Width
Heat output
Model
Overall weight
Depth
kW
, mm
B, mm
kg
20
970
570
1330
238
25
1050
570
1330
260
30
1050
630
1330
282
40
1050
730
1330
318
50
1100
730
1330
342
WB-SA25
70
1225
730
1470
368
90
1225
790
1470
391
110
1225
850
1470
432
Height C, mm
Water volume L 92 100 105 118 128 141 156 171
bar 2.5Operating pressure 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Cold water inlet
Hot water outlet
Sleeve for sensor of safety valve
Drain
Safety heat evacuator inlet/outlet
150/945 150/945 150/945 180/930 180/930 206/1055 206/1055
G1"/130 G2"/135 G2"/135 G2"/135
G1"/1235G1"/285
G1"/1380G1"/365
G 1125"/ G"/ 1125 G"/ 1100 G"/ 1125 G"/ 1125 G"/ 1240 G"/ 1240 G"/ 1250
G"/110 G"/110 G"/125 G"/125
R"/1070 R"/1070 R"/1210 R"/1210 R"/1210
IJ
E
D
G
Flue F
H
G1"/130 G1"/130 G1"/130 G1"/130
G1"/1410G1"/395
G1"/1410G1"/425
G1"/1235G1"/285
G1"/1235G1"/315
G1"/1235G1"/315
G1"/1235G1"/365
G"/110 G"/110 G"/110 G"/110
R"/1070 R"/1070 R"/1070
206/1055
WB-SA20
WB-SA30
WB-SA40
WB-SA50
WB-SA70
WB-SA90
WB-SA110
Volume of combustion chamber L 58
400
62
400
73
400
84
400
97
500
120
600
133
600
160
600Max. length of wood chunks mm
by SUNSYSTEM
Resistance of thecombustion chamber
Pa
mbar 0.10 0.11 0.12 0.15 0.26 0.41 0.54 0.67
10 11 12 15 26 41 54 67
NES Ltd. 12 Madara Blvd, 9700 Shumen, Bulgaria tel: +359 54 874 546, fax: +359 54 874 556e-mail: [email protected]
Distributor:
The information provided herein is subject to change without prior notice.
D
GF
I
J
H