  • Ribbed chamber surface and three-pass fluegas flow for improved heat exchange

    Steel boiler with intelligent controller and electric fan for forced airfeed. Wood-fired boilers WB-S Active range in nominal output from20 to 110 kW to satisfy the heating demands of medium to large sizedspaces. They are engineered for burning solid fuel and provide theoption for fitting pellet, oil or gas-fired burners.

    Wood-fired boilerBURNiT WB-S Active

    Product Features

    Combustion chamber with large heat exchangingsurface and low chamber resistance

    Large firebox door ensures easy loading evenwith bigger wood chunks

    Burner flange on lower door for fitting gas, oil,or pellet burners

    Safety devices :1) Pressure relief valve 2,5 bar incl.in the delivery set2) Safety heat evacuator a tap-water-filled line passesthrough the upmost part of the boiler body. In case ofoverheating it is triggered open by a thermostatic valve(not included) to evacuate the heat off the boiler.

    Exchangeable metallic ash grate protects thechamber base from the flame

    by SUNSYSTEM

    Electronic control unit controls the combustionby modulating the fan speed. Optional control ofcirculation pumps for DHW and central heating.

    Electric fan for forced air feed optimizes thecombustion and the fuel consumption rate

    Microprocessorcontrol unit

    Mineral woolinsulation

    Upper door

    Safety heat evacuator

    Watermantle

    Burner flange

    Exchangeable ash grate

    Rock woolinsulation

    Lower door

    Drain

    Air ventingarrangement

    Cold waterinlet

    Inspectionopening

    Chimney

    Hot water outlet

    Sensor

    Safety heatevacuatorinlet/outlet

    Design complying with EN 303-5

  • Required chimney draftPa

    mbar 0.16 0.20 0.21 0.23 0.24 0.38 0.47 0.56

    16 20 21 23 24 38 47 56

    Technical specification:

    Width

    Heat output

    Model

    Overall weight

    Depth

    kW

    , mm

    B, mm

    kg

    20

    970

    570

    1330

    238

    25

    1050

    570

    1330

    260

    30

    1050

    630

    1330

    282

    40

    1050

    730

    1330

    318

    50

    1100

    730

    1330

    342

    WB-SA25

    70

    1225

    730

    1470

    368

    90

    1225

    790

    1470

    391

    110

    1225

    850

    1470

    432

    Height C, mm

    Water volume L 92 100 105 118 128 141 156 171

    bar 2.5Operating pressure 2.5 2.5 2.5 2.5 2.5 2.5 2.5

    Cold water inlet

    Hot water outlet

    Sleeve for sensor of safety valve

    Drain

    Safety heat evacuator inlet/outlet

    150/945 150/945 150/945 180/930 180/930 206/1055 206/1055

    G1"/130 G2"/135 G2"/135 G2"/135

    G1"/1235G1"/285

    G1"/1380G1"/365

    G 1125"/ G"/ 1125 G"/ 1100 G"/ 1125 G"/ 1125 G"/ 1240 G"/ 1240 G"/ 1250

    G"/110 G"/110 G"/125 G"/125

    R"/1070 R"/1070 R"/1210 R"/1210 R"/1210

    IJ

    E

    D

    G

    Flue F

    H

    G1"/130 G1"/130 G1"/130 G1"/130

    G1"/1410G1"/395

    G1"/1410G1"/425

    G1"/1235G1"/285

    G1"/1235G1"/315

    G1"/1235G1"/315

    G1"/1235G1"/365

    G"/110 G"/110 G"/110 G"/110

    R"/1070 R"/1070 R"/1070

    206/1055

    WB-SA20

    WB-SA30

    WB-SA40

    WB-SA50

    WB-SA70

    WB-SA90

    WB-SA110

    Volume of combustion chamber L 58

    400

    62

    400

    73

    400

    84

    400

    97

    500

    120

    600

    133

    600

    160

    600Max. length of wood chunks mm

    by SUNSYSTEM

    Resistance of thecombustion chamber

    Pa

    mbar 0.10 0.11 0.12 0.15 0.26 0.41 0.54 0.67

    10 11 12 15 26 41 54 67

    NES Ltd. 12 Madara Blvd, 9700 Shumen, Bulgaria tel: +359 54 874 546, fax: +359 54 874 556e-mail: [email protected]

    Distributor:

    The information provided herein is subject to change without prior notice.

    D

    GF

    I

    J

    H