21
Casey Diehl, WegoWise Account Manager Building Smart Retrots with Tracking and Benchmarking

Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Casey Diehl, WegoWise Account Manager

Building Smart Retrofits with Tracking and

Benchmarking

Page 2: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Motivation for implementing energy efficiency

•  End of Useful Life •  Reduce Operating Cost •  Utility Allowances •  Capital/Rebate requires

energy reduction •  Increase asset value •  Protection against

obsolescence

•  Good Payback •  Good for the environment •  Improve tenant/occupant

comfort •  Be compliant with local

laws

Page 3: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Setting yourself up for success

Our Approach

Typical Approach to Retrofits

Page 4: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Part I: Tracking

Page 5: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Building Characteristics

Utility Data

Page 6: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM
Page 7: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Tracking Your Properties Spikes •  Leaks

Stepped increases •  Failing equipment

Page 8: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Part II: Benchmarking

Page 9: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

BTU/Cond. Sqft/HDD

38 29 14 8

BTU

?

Page 10: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Your To Do List

Page 11: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Your Targets

Page 12: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Your Targets

Your Targets

Page 13: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Part III: Results

Page 14: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Measure 736,000 Tracked Accounts = 8,832,000 Annual Bills = 5,888 feet

= ~ 1 Mile of Paper

Page 15: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Even for new buildings…

Page 16: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Cost of Delay

Winter 2008 $ 15,606

Winter 2013 $ 10,761

Difference $ 4,845

Life Time Energy Savings

$ 72,675

Other Savings Maintenance, tenant comfort

Cost to track $ 900

Page 17: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Improve

Page 18: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Improve Massachusetts Green Retrofit Initiative:

Gas Savings from Heating Replacements

Page 19: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Utility bills for inefficient buildings cost up to eight times more than

bills for efficient buildings

What We’re Learning

8x

Page 20: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

What we’re learning

What We’re Learning

Page 21: Building Smart Retrofits with Tracking and Benchmarking · Building Smart Retrofits with Tracking and Benchmarking.pptx Author: Casey Diehl Created Date: 9/29/2014 6:59:01 PM

Casey Diehl [email protected]

617-367-9346 x208