10
Town of Innisfil Community Development Standards Branch 2101 Innisfil Beach Road Innisfil, Ontario L9S 1A1 705-436-3710 Building Permit Requirements Digital Permit Application Submissions: [email protected] Inspection Requests: www.Innisfil.ca/eservices 705-436-3740 ext. 3500 General Inquiries: Customer Service 705-436-3710 Nottawasaga Valley Conservation Authority www.nvca.on.ca 705-424-1479 Lake Simcoe Region Conservation Authority www.lsrca.on.ca 905-895-1281 Decks The following information is required at submission. Complete submissions can be processed within 10 business days. Building Permit Application Package 1. Completed building permit application consisting of: Application for a Permit to Construct or Demolish" “Schedule 1: Designer Information” “Owner’s Authorization for Agent to Make an Application”, if applicable Conservation Authority Approval, if applicable 2. Two (2) copies of plans and specifications drawn to scale which must include: Site Plan showing: Entire property with lot dimensions The location, dimensions and setbacks to property lines of the proposed deck The dimensions and location of all existing buildings (i.e. house, shed) on the property Setbacks of the proposed deck to any on-site sewage system components, if applicable Plan and Section Drawings Foundation: Provide location, depth, size and spacing of piers. Framing: Provide dimensions of deck Height from finished grade Provide beam material, size, location, spacing, span of beams (between supports/piers) and method of attachment Provide joist material size, spacing and dimensions (span of joists between supports/beams) Provide flooring (decking) material size Provide proposed ledger connection details (if applicable) Roof over-hang design and details for a covered porch (if applicable) Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard connection details (as per the 2012 Ontario Building Code, Vol. 2. Supplementary Standard SB-7: available from the front counter at the Town of Innisfil)

Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

Town of Innisfil

Community Development Standards Branch

2101 Innisfil Beach Road

Innisfil, Ontario

L9S 1A1

705-436-3710

Building Permit Requirements

Digital Permit Application Submissions: [email protected]

Inspection Requests: www.Innisfil.ca/eservices 705-436-3740 ext. 3500

General Inquiries: Customer Service

705-436-3710

Nottawasaga Valley Conservation Authority www.nvca.on.ca

705-424-1479

Lake Simcoe Region Conservation Authority www.lsrca.on.ca

905-895-1281

Decks

The following information is required at submission. Complete submissions can be processed within 10 business days.

Building Permit Application Package

1. Completed building permit application consisting of:

“Application for a Permit to Construct or Demolish" “Schedule 1: Designer Information” “Owner’s Authorization for Agent to Make an Application”, if applicable Conservation Authority Approval, if applicable

2. Two (2) copies of plans and specifications drawn to scale which must include:

Site Plan showing:

Entire property with lot dimensions

The location, dimensions and setbacks to property lines of the proposed deck The dimensions and location of all existing buildings (i.e. house, shed) on the property Setbacks of the proposed deck to any on-site sewage system components, if applicable

Plan and Section Drawings

Foundation: Provide location, depth, size and spacing of piers.

Framing: Provide dimensions of deck Height from finished grade Provide beam material, size, location, spacing, span of beams (between

supports/piers) and method of attachment Provide joist material size, spacing and dimensions (span of joists between

supports/beams) Provide flooring (decking) material size Provide proposed ledger connection details (if applicable) Roof over-hang design and details for a covered porch (if applicable)

Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard connection details (as per the 2012 Ontario Building Code, Vol. 2.

Supplementary Standard SB-7: available from the front counter at the Town of Innisfil)

Page 2: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

Digital Permit Application Submissions: [email protected]

Inspection Requests: www.Innisfil.ca/eservices 705-436-3740 ext. 3500

General Inquiries: Customer Service

705-436-3710

Nottawasaga Valley Conservation Authority www.nvca.on.ca

705-424-1479

Lake Simcoe Region Conservation Authority www.lsrca.on.ca

905-895-1281

Town of Innisfil

Community Development Standards Branch

2101 Innisfil Beach Road

Innisfil, Ontario

L9S 1A1

705-436-3710

NOW ACCEPTING DIGITAL APPLICATIONS, PLEASE EMAIL YOUR COMPLETED BUILDING PERMIT APPLICATION

PACKAGE (including all required forms and one (1) copy of drawings) TO: [email protected] FOR MORE INFORMATION, PLEASE VISIT: innisfil.ca/buildingpermits

Building Permit Issuance

1. The applicant will be contacted and informed of any action required in order for the permit to be issued. 2. Permit fees are payable upon issuance. 3. Permit Fee: $350 per unit

Note: Fees are charged in accordance with the Town’s Fees and Charges By-law, and are subject to change.

Page 3: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

Application for a Permit To Construct or Demolish This for is authorized under subsection 8(1.1) of the Building Code Act

Town of InnisfilBuilding Department

2101 Innisfil Beach Road,INNISFIL, ON L9S 1A1

Tel : 705-436-37101-888-436-3710

Fax: 705-436-7120

For use by Principal Authority

Application number: Permit number (if different):

Date received: Roll number:

Application submitted to: The Town of Innisfil, 2101 Innisfil Beach Rd, Innisfil, Ontario

A. Project information Building number, street name Unit number Lot/con.

Municipality Postal code Plan number/other description

Project value est. $ Area of work (m2)

B. Purpose of application

New construction

Addition to an existing building

Alteration/ repair

Demolition Conditional Permit

Proposed use of building Current use of building

Description of proposed work

C. Applicant Applicant is: Owner or Authorized agent of owner Last name First name Corporation or partnership

Street address Unit number Lot/con.

Municipality Postal code Province E-mail

Telephone number ( )

Fax ( )

Cell number ( )

D. Owner (if different from applicant) Last name First name Corporation or partnership

Street address Unit number Lot/con.

Municipality Postal code Province E-mail

Telephone number ( )

Fax ( )

Cell number ( )

E. Builder (optional) Last name First name Corporation or partnership (if applicable)

Street address Unit number Lot/con.

Municipality Postal code Province E-mail

Telephone number ( )

Fax ( )

Cell number ( )

F. Tarion Warranty Corporation (Ontario New Home Warranty Program) i. Is proposed construction for a new home as defined in the Ontario New Home

Warranties Plan Act? If no, go to section G. Yes No

ii. Is registration required under the Ontario New Home Warranties Plan Act? Yes No

iii. If yes to (ii) provide registration number(s): ____________________________________

Page 4: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

G. Required Schedules i) Attach Schedule 1 for each individual who reviews and takes responsibility for design activities. ii) Attach Schedule 2 where application is to construct on-site, install or repair a sewage system.

H. Completeness and Compliance with Applicable Law

i) This application meets all the requirements of clauses 1.3.1.3 (5) (a) to (d) of Division C of the Building Code (the application is made in the correct form and by the owner or authorized agent, all applicable fields have been completed on the application and required schedules, and all required schedules are submitted).

Payment has been made of all fees required, under the applicable by-law, resolution or regulation made under clause 7(1)(c) of the Building Code Act, 1992, to be paid when the application is made.

Yes

Yes

No

No

ii) This application is accompanied by the plans and specifications prescribed by the applicable by-law, resolution or regulation made under clause 7(1)(b) of the Building Code Act, 1992.

Yes No

iii) This application is accompanied by the information and documents prescribed by the applicable by-law, resolution or regulation made under clause 7(1)(b) of the Building Code Act, 1992 which enable the chief building official to determine whether the proposed building, construction or demolition will contravene any applicable law.

Yes No

iv) The proposed building, construction or demolition will not contravene any applicable law.

Yes No

I. Declaration of applicant

I _____________________________________________________________________________declare that: (print name)

1. The information contained in this application, attached schedules, attached plans and specifications, and other attached documentation is true to the best of my knowledge.

2. If the owner is a corporation or partnership, I have the authority to bind the corporation or partnership.

___________________________ _________________________________________________________________

Date Signature of applicant

Personal information contained in this form and schedules is collected under the authority of subsection 8(1.1) of the Building Code Act, 1992, and will be used in the administration and enforcement of the Building Code Act,1992. Questions about the collection of personal information may be addressed to: a)The Chief Building Official of the municipality or upper-tier municipality to which this application is being made or, b) the inspector having the powers and duties of a Chief Building Official in relation to sewage systems or plumbing for an upper-tier municipality, board of health or conservation authority to whom this application is made or c) Director, Building and Development Branch, Ministry of Municipal Affairs and Housing777 Bay St., 2nd Floor. Toronto, ON M5G 2E5 (416) 585-6666

Page 5: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

Application for a Permit to Construct or Demolish – Effective January 1, 2011

Schedule 1 Designer Information

Town of InnisfilBuilding Department

2101 Innisfil Beach Road,INNISFIL, ON L9S 1A1

Tel : 705-436-37101-888-436-3710

Fax: 705-436-7120

Use one form for each individual who reviews and takes responsibility for design activities with respect to the project.

A. Project Information Building number, street name Unit no. Lot/con.

Municipality Postal code Plan number/ other description

B. Individual who reviews and takes responsibility for design activities Name Firm

Street address Unit no. Lot/con.

Municipality Postal code Province E-mail

Telephone number ( )

Fax number ( )

Cell number ( )

C. Design activities undertaken by individual identified in Section B. [Building Code Table 3.5.2.1. of Division C]

House Small Buildings Large Buildings Complex Buildings

HVAC – House Building Services Detection, Lighting and Power Fire Protection

Building Structural Plumbing – House Plumbing – All Buildings On-site Sewage Systems

Description of designer’s work

D. Declaration of Designer

I ________________________________________________ declare that (choose one as appropriate):

(print name)

I review and take responsibility for the design work on behalf of a firm registered under subsection 3.2.4.of Division C, of the Building Code. I am qualified, and the firm is registered, in the appropriate classes/categories.

Individual BCIN: _________________________________ Firm BCIN: _________________________________

I review and take responsibility for the design and am qualified in the appropriate category as an “other designer” under subsection 3.2.5.of Division C, of the Building Code.

Individual BCIN: _________________________________ Basis for exemption from registration: ___________________________________

The design work is exempt from the registration and qualification requirements of the Building Code.

Basis for exemption from registration and qualification:__________________________________________

I certify that: 1. The information contained in this schedule is true to the best of my knowledge. 2. I have submitted this application with the knowledge and consent of the firm. ___________________________ _________________________________________________

Date Signature of Designer

NOTE:

1. For the purposes of this form, “individual” means the “person” referred to in Clause 3.2.4.7(1) d).of Division C, Article 3.2.5.1. of Division C, and all other persons who are exempt from qualification under Subsections 3.2.4. and 3.2.5. of Division C.

2. Schedule 1 is not required to be completed by a holder of a license, temporary license, or a certificate of authorization, issued by the Ontario Association of Architects. Schedule 1 is also not required to be completed by a holder of a license to practise, a limited license to practise, or a certificate of authorization, issued by the Association of Professional Engineers of Ontario.

Page 6: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

Owner’s Authorization for Agent to Make an Application

Town of InnisfilBuilding Department

2101 Innisfil Beach Road,INNISFIL, ON L9S 1A1

Tel : 705-436-37101-888-436-3710

Fax: 705-436-7120

Date: _____________________________ Permit No.: ______________________________

Proposed Work: ________________________________________________________________

Location: _____________________________________________________________________

The undersigned, being the owner(s) of the above referenced property, authorizes

________________________________ ________________________________

Applicant Name Address

to apply for a permit for the above referenced project on my behalf. I understand that I shall be

responsible for the terms of the conditions contained in the permit.

(If owner is an INDIVIDUAL)

___________________________________ ___________________________________

Owner’s Name Address

___________________________________ ___________________________________

Owner’s Signature Phone No. / E-Mail

(If owner is a CORPORATION)

___________________________________ ___________________________________

Owner’s Name Address

___________________________________ ___________________________________

Name of Authorizing Officer Phone No. / E-Mail

___________________________________

Signature of Authorizing Officer ( I have authority to bind the Corporation )

Rev 02 Dec 1/11

Page 7: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

PROVIDE AREAOF HOUSE

WITHATTACHED

GARAGE(m²)

PROVIDEAREA OF

STRUCTURESON THE

PROPERTY(m²)

SEPTIC SYSTEM

SEPTICTANK

PROVIDE LOCATION OFSEPTIC COMPONENTS

A

B

A = MIN. DISTANCE OF 5MB = MIN. DISTANCE OF 1.5M

Page 8: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

UNSUPPORTED BEAM SPANBETWEEN PIERS

UN

SUPP

ORT

ED J

OIS

T SP

AN

BETW

EEN

BEA

M &

LED

GER

AS PER O.B.C. DIV. 9,PT.9, TABLEA­8

Page 9: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

LEDGER BOARD FASTENER SPACING

min

.

2"

2" min.

typical spacing

approved fasteners;

stagger in 2 rows

5.5" min. for 2x8

6.5" min. for 2x10

7.5" min. for 2x12

NO LEAD ANCHORS

COLUMNS SHALL BESECURELY FASTENED TO THESUPPORTED MEMBER FORLATERAL SUPPORT AS PERO.B.C. DIV. B 9.17.2.2.

MAX. RISE SHALL BE 7 7/8"FOR STAIRS (MIN. RISE =4 7/8"); STEP DIMENSIONSSHALL COMPLY WITHO.B.C. DIV. B 9.8.4.

HANDRAILS ARE REQUIREDWHERE THERE ARE MORETHAN 3 RISERS FOREXTERIOR STAIRS;HANDRAIL DESIGN SHALLCOMPLY WITH O.B.C. DIV. B9.8.7.

STAIRS AND HANDRAILS

NOTE: A GUARD IS REQUIREDWHERE THERE IS ADIFFERENCE OF ELEVATIONOF MORE THAN 600MMBETWEEN THE WALKINGSURFACE AND THE ADJACENTSURFACE AS PER O.B.C. DIV. B9.8.8.1.

2

1/4"

3 1/

4"2

1/4"

cdsb2
May 4, 2018
8"
cdsb2
May 4, 2018
2" x 8"
cdsb2
May 4, 2018
7
cdsb2
May 4, 2018
2" x 8"
cdsb2
May 4, 2018
7 1/4"
cdsb2
May 4, 2018
2" x 8" RIM JOIST
cdsb2
May 4, 2018
2" X 8"
cdsb2
May 4, 2018
2" X 8" DECK JOISTS
cdsb2
May 4, 2018
1/4"
Page 10: Building Permit Application Package€¦ · Stair, guard and railing detail (if applicable) Number and height of risers Height of proposed handrails and guards (if applicable) Guard

SPAN TABLES FOR JOISTS, BEAMS PIERS

JOIST SPAN

Size Spacing Span

2 x 8

12” o/c 12’-0”

16” o/c 11’-0”

2 x 10

12” o/c 14’-0”

16” o/c 13’-0”

2 x 12 12” o/c 14’-0”

16” o/c 14’-0”

Note: All lumber SPF or better - Solid blocking required if span exceeds 6’-11” BEAM SPANS

Pier spacing

6’-0” 8’-0” 10’-0” 12’-0” 14’-0”

6’-0” 3 ply 2x8 3 ply 2x8 3 ply 2x8 3 ply 2x10 3 ply 2x12 4 ply 2x10

8’-0” 3 ply 2x8 3 ply 2x8 3 ply 2x8 3 ply 2x10 3 ply 2x12 4 ply 2x10

10’-0" 3 ply 2x8 3 ply 2x8 3 ply 2x10 3 ply 2x12 4ply 2x10

12’-0” 3 ply 2x8 3 ply 2x8 3 ply 2x10 4 ply 2x8

3 ply 2x10 3 ply 2x12 4ply 2x10

14’-0” 3 ply 2x8 3 ply 2x10 3 ply 2x10 4 ply 2x8

3 ply 2x12 4ply 2x10

3 ply 2x12 4ply 2x10

PIER SIZES (Diameter in inches)

Joist Span Pier Spacing

4’-0” 6’-0” 8’-0” 10’-0” 12’-0” 14’-0”

6’-0” 8” 8” 10” 10” *

8’-0” 8” 10” 10” 12” *

10’-0” 10” 10” 12” 12” *

12’-0” 10” 12” 12” 15” *

14’-0” 12” 12” 15” 21” *

Note:

DECK LEDGER TO HOUSE ATTACHMENT – LAG BOLT SPACING (SEE DIAGRAMS)

LAG BOLT SIZE

JOIST SPAN

Up to 6’-0” (1.8m) 8’-0” (2.4m) 10’-0” (3.0m) 12’-0” (3.6m)

1/2” (12.7mm) 32”o.c. (812mm) 16”o.c. (400mm) 16”o.c. (400mm) 12”o.c. (300mm)

Equivalent 16” O.C.

Joist Spacing

Every Other Joist Space

Every Joist Space Every Joist Space Each Joist Space with Two Every

Other Space

3/8” (9.5mm) 24”o.c. ( ) 12”o.c. (300mm) 12”o.c. (300mm) 8”o.c. (200mm)

Equivalent 16” O.C.

Joist Spacing

Two Every Third Joist Space

Each Joist Space with Two Every

Other Space

Each Joist Space with Two Every

Other Space

Two Each Joist Space Three

Every Other Space

Joist span

610mm

Note: Sleeve anchors are not permitted

cdsb2
May 4, 2018
Note: Only approved fasteners shall be used for the ledger-to-house attachment; lag bolts or through-bolts with washers (see the table above for sizing and spacing)
cdsb1
Text Box
3 ply 2x8