PERFORMANCE SPECIFICATIONS Repeatability of analysis: + 0.05% of heat value FUNCTIONAL SPECIFICATIONS Principle of measurement: Gas chromatography Measured gas streams: Up to 4 streams Analyzed components: 11 Analysis time (standard): 300 sec. Detector: Micro TCD (Thermal Conductivity Detector) Chromatographic methods: ISO 6974, part 4 Heat value calculation methods: GPA 2172 Gas to be analyzed: Natural gas Auto-calibration: External solenoid valve & contact required Normalization of concentrations On-line diagnostics Types of protection: FM Approvals Explosion proof for Cl I, Div 1, Groups C & D, T4 Flameproof for Cl I, Zone 1 AEX d IIB T4 Seal all conduits within 18 inches NEMA Type 4X IP 65 CE mark: Electromagnetic compatibility (89/336/EEC, 92/31/EEC, 93/68/EEC) Analyzer output protocol: Foundation Fieldbus MODBUS RTU or ASCII via RS-232, 485, 422 Analog: 4-20mA PROCESS GAS CONDITIONS Temperature: 14°F to 122°F (-10°C to 50°C) Flow rate: 50 + 20 ml/min Pressure: 7 to 70 psig measured at flow meter inlet Dust and mist: None Moisture: 2000 ppm or less Coexisting component limits: H 2 , He, O 2 , H 2 S (dry) < 0.1 mol% each Ambient humidity range: 0-95%RHPerformance Specifications RANGES AND DETECTION LIMITS Components Range Minimum Detection (mol %) (mol %) Sum of C 6 + 0 - 0.3 0.01 C 3 H 8 (propane) 0 - 3 0.05 i-C 4 H 10 (i-butane) 0 - 1 0.01 n-C 4 H 10 (n-butane) 0 - 1 0.01 neo-C 5 H 12 (neo-pentane) 0 - 0.5 0.01 i-C 5 H 12 (i-pentane) 0 - 0.5 0.01 n-C 5 H 12 (n-pentane) 0 - 0.5 0.01 N 2 (nitrogen) 0 - 20 0.1 CH 4 (methane) 50 - 100 - CO 2 (carbon dioxide) 0 - 10 0.05 C 2 H 6 (ethane) 0 - 15 0.05 INSTALLATION SPECIFICATIONS Color: Metallic light green, silver Material: Body: Cast aluminum Oven: Cast aluminum Wet-parts: 304 Stainless steel, Polyimide Sensor: Pt, Glass, Gold Dimensions: W: 3.9 in. x D: 4.5 in. x H: 9.6 in. Weight: 7.7 lbs Mounting: Vertical 2 inch pipe mount Ambient temperature limits: 14°F to 122°F (-10°C to 50°C) -40°F to 158°F (-40°C to 70°C) for storage and transportation Power supply: 24 VDC + 15% 4A minimum Power consumption: 5 - 50 VA at 50°C to -10°C Carrier gas: 99.99% Helium (or better purity) Carrier gas pressure: 60 psig + 7 psig Carrier gas flow rate: 25ml/min Valve actuation: Instrument air or helium carrier gas 60 psig + 7 psig TECHNICAL SPECIFICATIONS COSA INSTRUMENT CORPORATION Texas Office: 7125 North Loop East, Houston, TX 77028 Tel: 713-947-9591, Fax: 713-947-7549 New York Office: 84F Horseblock RD, Yaphank, NY 11962 Tel: 631-345-3434, Fax: 631-924-7337 E-mail: [email protected] www.cosaxentaur.com Represented by: The HGC 303 is the world’s smallest gas chromatograph for C 6 + analysis of Natural Gas. It digitally publishes 20 derived parameters, such as Calorific Value, Wobbe Index, Specific Gravity, Compressibility, Ratio of Heats, etc. BTU Gas Chromatograph HGC 303 The “Out of the Box” Transmitter Solution for NATURAL GAS ANALYSIS Compact and Lightweight Design Easy Installation Field Mountable at the Pipeline No Analyzer Shelter Required Eliminates Repairs in the Field Analysis of 11 Components in 300 Seconds Calculation of 20 Parameters Optional Digital & Analog Outputs Foundation Fieldbus and MODBUS Communications Approved for Use in Class I, Division 1 Groups C and D Meets ISO and GPA standards Class I Div1 Grps CD, T4 www.cosaxentaur.com

BTU Gas Chromatograph Components Range Minimum Detection ...€¦ · BTU Gas Chromatograph HGC 303 The “Out of the Box” Transmitter Solution for NATURAL GAS ANALYSIS • Compact

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BTU Gas Chromatograph Components Range Minimum Detection ...€¦ · BTU Gas Chromatograph HGC 303 The “Out of the Box” Transmitter Solution for NATURAL GAS ANALYSIS • Compact

PERFORMANCE SPECIFICATIONSRepeatability of analysis: + 0.05% of heat value

FUNCTIONAL SPECIFICATIONSPrinciple of measurement: Gas chromatography

Measured gas streams: Up to 4 streams

Analyzed components: 11

Analysis time (standard): 300 sec.

Detector: Micro TCD (Thermal Conductivity Detector)

Chromatographic methods:

ISO 6974, part 4

Heat value calculation methods:

GPA 2172

Gas to be analyzed: Natural gas

Auto-calibration: External solenoid valve & contact required

Normalization of concentrations

On-line diagnostics

Types of protection:

FM Approvals

Explosion proof for Cl I, Div 1, Groups C & D, T4

Flameproof for Cl I, Zone 1 AEX d IIB T4

Seal all conduits within 18 inches

NEMA Type 4X

IP 65

CE mark: Electromagnetic compatibility (89/336/EEC, 92/31/EEC, 93/68/EEC)

Analyzer output protocol:

Foundation Fieldbus

MODBUS RTU or ASCII via RS-232, 485, 422

Analog: 4-20mA

PROCESS GAS CONDITIONSTemperature: 14°F to 122°F (-10°C to 50°C)

Flow rate: 50 + 20 ml/min

Pressure: 7 to 70 psig measured at flow meter inlet

Dust and mist: None

Moisture: 2000 ppm or less

Coexisting component limits:

H2, He, O2, H2S (dry) < 0.1 mol% each

Ambient humidity range: 0-95%RHPerformance Specifications

RANGES AND DETECTION LIMITSComponents Range Minimum Detection (mol %) (mol %)Sum of C6+ 0 - 0.3 0.01

C3H8 (propane) 0 - 3 0.05

i-C4H10 (i-butane) 0 - 1 0.01

n-C4H10 (n-butane) 0 - 1 0.01

neo-C5H12 (neo-pentane) 0 - 0.5 0.01

i-C5H12 (i-pentane) 0 - 0.5 0.01

n-C5H12 (n-pentane) 0 - 0.5 0.01

N2 (nitrogen) 0 - 20 0.1

CH4 (methane) 50 - 100 -

CO2 (carbon dioxide) 0 - 10 0.05

C2H6 (ethane) 0 - 15 0.05

INSTALLATION SPECIFICATIONSColor: Metallic light green, silver

Material:

Body: Cast aluminum

Oven: Cast aluminum

Wet-parts: 304 Stainless steel, Polyimide

Sensor: Pt, Glass, Gold

Dimensions: W: 3.9 in. x D: 4.5 in. x H: 9.6 in.

Weight: 7.7 lbs

Mounting: Vertical 2 inch pipe mount

Ambient temperature limits:

14°F to 122°F (-10°C to 50°C)

-40°F to 158°F (-40°C to 70°C) for storage and transportation

Power supply: 24 VDC + 15% 4A minimum

Power consumption: 5 - 50 VA at 50°C to -10°C

Carrier gas: 99.99% Helium (or better purity)

Carrier gas pressure: 60 psig + 7 psig

Carrier gas flow rate: 25ml/min

Valve actuation:

Instrument air or helium carrier gas

60 psig + 7 psig

TECHNICAL SPECIFICATIONS

COSA INSTRUMENT CORPORATIONTexas Office: 7125 North Loop East, Houston, TX 77028 Tel: 713-947-9591, Fax: 713-947-7549

New York Office: 84F Horseblock RD, Yaphank, NY 11962 Tel: 631-345-3434, Fax: 631-924-7337 E-mail: [email protected]

Represented by:

The HGC 303 is the world’s smallest gas chromatograph for

C6+ analysis of Natural Gas. It digitally publishes 20 derived

parameters, such as Calorific Value, Wobbe Index, Specific

Gravity, Compressibility, Ratio of Heats, etc.

BTU Gas ChromatographHGC 303

The “Out of the Box”

Transmitter Solution for NATURAL GAS ANALYSIS

• Compact and Lightweight Design

• Easy Installation

• Field Mountable at the Pipeline

• No Analyzer Shelter Required

• Eliminates Repairs in the Field

• Analysis of 11 Components in 300 Seconds

• Calculation of 20 Parameters

• Optional Digital & Analog Outputs

• Foundation Fieldbus and MODBUS Communications

• Approved for Use in Class I, Division 1 Groups C and D

• Meets ISO and GPA standards

Class I Div1 Grps CD, T4

www.cosaxentaur.com

Page 2: BTU Gas Chromatograph Components Range Minimum Detection ...€¦ · BTU Gas Chromatograph HGC 303 The “Out of the Box” Transmitter Solution for NATURAL GAS ANALYSIS • Compact

PRE-ENGINEERED NATURAL GAS ANALYSIS

The HGC303 offers pre-engineered analysis and calculations

for natural gas monitoring, eliminating the need for any

further programming and application work. Hooking up gas

connections, power and communications cables is all that is

required to get this plug and play transmitter ready to work.

The HGC303 provides a full 11-component C6+

analysis on natural gas with a 300-second cycle time and a

repeatability of 0.05% Heating Value. The HGC calculates

and digitally transmits 20 gas parameters according to GPA

or ISO Standard, including Upper and Lower Heating Values,

Wobbe Index, Specific Gravity, Compressibility and Specific

Heat Ratio.

LOW COST OF OWNERSHIP

Low analyzer price, easy installation, low maintenance and reliable performance contribute to time

and cost savings and a low overall cost of ownership.

LOW MAINTENANCE

The HGC303 is designed to perform reliably in natural gas applications ranging from remote

wellheads to gas processing plants, gas transmission and distribution points and endusers. The

HGC’s small and light-weight design facilitates a simple swap-out of the entire analyzer in minutes,

rather than requiring cumbersome maintenance in the field.

OUTPUT DATAPV1 Sum of C6+PV2 C3H8PV3 i-C4H10PV4 n-C4H10PV5 neo-C5H12PV6 i-C5H12PV7 n-C5H12PV8 N2PV9 CH4PV10 CO2PV11 C2H6PV12 Real Gross Heat ValuePV13 Gas DensityPV14 Wobbe IndexPV15 Compressibility FactorPV16 Total of Raw ConcentrationPV17 Oven TemperaturePV18 Carrier Gas TemperaturePV19 Lower Heat ValuePV20 Relative Density

SMALL SIZE FOR EASY FIELD INSTALLATION

The HGC303 is engineered to take full advantage of

Yamatake Corporation’s leading sensing and control

technology, packing into the compact design of a

9.6” tall field transmitter the features, functionality and

performance of a full sized chromatograph. Intrinsic

safety and weatherproof design allow installation at the

pipeline without additional sheltering.

EASY TO USE WINDOWS™ BASED SOFTWARE

The HGC can communicate with a PC via the HFA

Fieldbus/USB converter. Windows®* based software

(HGM) provides an easy-to-use interface for viewing data

and diagnostic information and to perform instrument set-

up functions. In particular, the HGM software:

• Stores 300 chromatograms

• Trends BTU values

• Trends carrier gas pressure and oven temperature

• Stores raw and calculated data values

• Indicates operational status and diagnostic values

• Allows instrument set-up in a convenient environment*The HGM software requires Windows® 98,Windows® Me, Windows® 2000, Windows® NT.

DIGITAL COMMUNICATIONS

The HGC303 communicates via Foundation Fieldbus™ protocol with

external devices and can be connected to a PC via a Fieldbus™/

USB adapter (Model HFA).

The HGC can be integrated with existing SCADA systems via a

companion device, the HDM Data Manager. The HDM is a Class I Div

2, field-mountable converter that offers MODBUS communications

as well as a total of three additional digital or analog outputs (RS-

232, RS-422, RS-485; 4-20 mA).

The Yamatake HGC303 BTU Gas Chromatograph and MODBUS

Interface have been tested for compatibility with the leading

manufacturers of flow computers insuring seamless integration into

your gas metering system.

NATURAL GAS SAMPLING SYSTEM

The HGC is available with a modular sample conditioning

system, assuring a cost effective, application specific

solution for a reliable delivery of a clean and dry sample,

even under the most adverse conditions. The sample

system provides connections and functionality for automatic

calibration. Optionally available is the integration of a

moisture measurement using a Xentaur HTF™ moisture

sensor and transmitter.

Model HDM

Shown here: Class I Div 1 sample system with sample conditioning and heater for extreme conditions.

HGC.D.BR.0001_A