1.A1 Alarm Cell Logical channel availability Supervision CHTYPE BCCH SDCCH TCH RXTCP:MOTY=RXOTG,CELL=calla; CellID ,TG,CHGR RXTCP:MOTY=RXOTG-a; all Cells, All chgr number RXASP:MO=RXOTG-a; Alarm situation OML fautl RXAPP:MO=RXOTG-X; To Get TEI VAULE & RBLT DEVICE RADEP:DEV=RBLT-X, TO Get snt name NTCOP:SNT=snt-x,dipinf; TO Device,SNTL,dip name DTSTP:DIP=dip; To get DIP status RLCRP:CELL=cell; To know Total traffic channel & BCCH,TCH & BCCH Busy. RLSTP:CELL=cell, state=halted; To know number of halted cell RLSTC:CELL=cell, State=active; To make cell active DTQSR:DIP=ALL,DEGR,UNACC,SF; 2. Troubleshooting way to BSC Fault RXTCP:MOTY=RXOTG,CELL=....;tg=X RXCDP:MO=RXOTG-X; get how is tru working and how many define RXAPP:MO=RXOTG-X; get how many dcp connected GET ANY DEV=RBLT-Y RADEP:DEV=RBLT-Y; get the E1 number RXMFP:MO=RXOCF-X; check if there is any Class 2 fault RXMSP:MO=RXOCF-X; check the status of cf and you can do the same for trx or tx or.... 3.To Reset Site If Is Down RXBLI:MO=RXOCF-8,SUBORD,FORCE; RXESE:MO=RXOCF-8,SUBORD; RXESI:MO=RXOCF-8,SUBORD; RXBLE:MO=RXOCF-8,SUBORD;

Bsc Commands

Embed Size (px)

Citation preview

1.A1 Alarm Cell Logical channel availability SupervisionCHTYPE BCCH SDCCH TCH

RXTCP:MOTY=RXOTG,CELL=calla; CellID ,TG,CHGR

RXTCP:MOTY=RXOTG-a; all Cells, All chgr number

RXASP:MO=RXOTG-a; Alarm situation OML fautl

RXAPP:MO=RXOTG-X; To Get TEI VAULE & RBLT DEVICE

RADEP:DEV=RBLT-X, TO Get snt name

NTCOP:SNT=snt-x,dipinf; TO Device,SNTL,dip name

DTSTP:DIP=dip; To get DIP status

RLCRP:CELL=cell; To know Total traffic channel & BCCH,TCH & BCCH Busy.

RLSTP:CELL=cell, state=halted; To know number of halted cell

RLSTC:CELL=cell, State=active; To make cell active

DTQSR:DIP=ALL,DEGR,UNACC,SF;

2. Troubleshooting way to BSC Fault

RXTCP:MOTY=RXOTG,CELL=....;tg=XRXCDP:MO=RXOTG-X; get how is tru working and how many defineRXAPP:MO=RXOTG-X; get how many dcp connected GET ANY DEV=RBLT-YRADEP:DEV=RBLT-Y; get the E1 numberRXMFP:MO=RXOCF-X; check if there is any Class 2 faultRXMSP:MO=RXOCF-X; check the status of cf and you can do the same for trx or tx or....

3.To Reset Site If Is Down RXBLI:MO=RXOCF-8,SUBORD,FORCE; RXESE:MO=RXOCF-8,SUBORD; RXESI:MO=RXOCF-8,SUBORD; RXBLE:MO=RXOCF-8,SUBORD; RLCRP:CELL=TQJ1A; RXTCP:MOTY=RXOTG,CELL= TQJ1A;

4.RXOTRX fault code 1b2 CDU POWER EXCEDED.

4-TO BRING CELL SECTOR FOR BSC:

RLCRP:CELL=CELL; ! NO CHANNEL BUSY!

RXTCP:MOTY=RXOTG; ! CHECK TG STATUS!

RXMSP:MO=RXOTG-140; ! TG STATUS!

RXMSP:MO=RXOCF-140; ! CF=TG STATUS!

RXMSP:MO=RXOCF-140,SUBORD; ! RADIO X-CEIVER ADMINISTRATION MANAGED OBJECT STATUS!

RXBLI:MO=RXOTG-180,SUBORD,FORCE; ! BLCOK FAULTY CELL!

RXESE:MO=RXOTG-180,SUBORD; !TAKE OUT OF SERVICE !

RXESI:MO=RXOTG-180,SUBORD;

RXBLE:MO=RXOTG-180,SUBORD

To Attend TS sync fault

FirstRXBLI:MO=RXESE:MO=RXESI:MO=RXPLI:MO=RXBLE:MO=

To know in which sector TRX is available

RXMOP:MO=RXOTRX-A-B;

To know configuration of cell site

RXCDP:MO=RXOTG-X; !managed object configuration Data

To count total number of TRX in TG count total number of RXORX or

RXOTX.

Go to MO last

Count yes to no RXOTX.

RXCDP:MO=RXOTG-X;

RXCFP:CELL=cell; Cell configuration frequency data

TRU replacement:

Changing TRU start count Numbers are like 0,1,2,3,4,7But count number from 1,2,3,----7.

RXBLI:MO=RXOTRX-A-B,SUBORD; Where A=TG Number and B=TRU number.

RXMSP:MO=RXOTRX-A-B; Check weather it is blocked or not.

Change TRU

RXBLE:MO=RXOTRX-A-B;

RXMSP:MO=RXOTRX-A-B;

ALLIP:ACL=A1,ALCAT=APT;

ALLIP:ACL=A2,ALCAT=APT;

ALLIP; Weather there is no alarm related to TRU.

5- IF A SITE IS DOWN CHK STATUS

RLSTP:CELL=YYYYY; (YYYYY- CELL NAME) CHECK FOR STATUS ACTIVERLCRP:CELL=YYYYY; CHECK FOR CELL RESOURCES IF THERE ARE 3 TRUS TRAFFIC CHANNEL SHOULD BE 22, 2 TRU- 14, 1 TRU -7 ,4TRU - 29/30 TCH

BLOCK AND DEBLOCK MANAGED OBJECTS IN THE ORDERTS,RX,TX,TRX,DP,CON,TF,IS,CF,TG,

RXBLI BLOCKING,RXESE END OF SERVICE,RXMSP STATUS PRINT,RXESI SERVICE INITIATERXBLE DEBLOCKING.IF U WANT TO PROCEED MO ONE BY ONE THEN GIVE

A- TG NUMBERB- TRX NUMBER0&&7 - TIME SLOTS

RXBLI:MO=RXOTS-A-B-0&&-7,FORCE;RXBLI:MO=RXORX-A-B,FORCE;RXBLI:MO=RXOTX-A-B,FORCE;RXBLI:MO=RXOTRX-A-B,FORCE;RXBLI:MO=RXODP-A-B,FORCE;RXBLI:MO=RXOCON-A,FORCE;RXBLI:MO=RXOTF-A,FORCE;RXBLI:MO=RXOIS-A,FORCE;RXBLI:MO=RXOCF-A,FORCE;RXBLI:MO=RXOTG-A,FORCE;

RXESE:MO=RXOTS-A-B-0&&-7;RXESE:MO=RXORX-A-B;

RXESE:MO=RXOTX-A-B;RXESE:MO=RXOTRX-A-B;RXESE:MO=RXODP-A-B;RXESE:MO=RXOCON-A;RXESE:MO=RXOTF-A;RXESE:MO=RXOIS-A;RXESE:MO=RXOCF-A;RXESE:MO=RXOTG-A;

RXESI:MO=RXOTG-A;RXESI:MO=RXOCF-A;RXESI:MO=RXOIS-A;RXESI:MO=RXOTF-A;RXESI:MO=RXOCON-A;RXESI:MO=RXODP-A-B;RXESI:MO=RXOTRX-A-B;RXESI:MO=RXOTX-A-B;RXESI:MO=RXORX-A-B;RXESI:MO=RXOTS-A-B-0&&-7;

RXBLE:MO=RXOTG-A;RXBLE:MO=RXOCF-A;RXBLE:MO=RXOIS-A;RXBLE:MO=RXOTF-A;RXBLE:MO=RXOCON-A;RXBLE:MO=RXODP-A-B;RXBLE:MO=RXOTRX-A-B;RXBLE:MO=RXOTX-A-B;RXBLE:MO=RXORX-A-B;RXBLE:MO=RXOTS-A-B-0&&-7;

IF U WANT TO BLOCK ALL IN ONE GO THEN GIVE RXBLI:MO=RXOCF-A,SUBORD,FORCE; OR RXBLI:MO=RXOTRX-A-B,SUBORD,FORCE; RXESE:MO=RXOCF-A,SUBORD; OR RXESE:MO=RXOTRX-A-B,SUBORD;RXESI:MO=RXOCF-A,SUBORD; OR RXESI:MO=RXOTRX-A-B,SUBORD;RXBLE:MO=RXOCF-A,SUBORD; OR RXBLE:MO=RXOTRX-A-B,SUBORD;

U CAN ALSO USE BSM IN THE OSS WINDOW TO GET THE APPROPRIATE COMMAND.

6. MO FAULT CODE LIST

********************************************************************************

CF, EXTERNAL CONDITION MAP CLASS 1

4 L/R SWI (BTS IN LOCAL MODE)5 L/R TI (LOCAL TO REMOTE WHILE LINK LOST)

CF, EXTERNAL CONDITION MAP CLASS 2

7 DIP A (PCM LINK A LOST)9 BTS DOOR OPEN

CF, INTERNAL FAULT MAP CLASS 1A

0 RESET, FAILED RESTART ATTEMPT1 RESET, POWER ON2 RESET, SWITCH3 RESET, WATCHDOG4 RESET, SW FAULT5 RESET, RAM FAULT6 RESET, INTERNAL FUNCTION CHANGE7 X BUS FAULT8 TIMING UNIT VCO FAULT9 TIMING BUS FAULT10 INDOOR TEMPERATURE OUT OF SAFE RANGE12 DC VOLTAGE OUT OF RANGE14 LOCAL BUS FAULT15 BTS DATABASE CORRUPTED16 RU DATABASE CORRUPTED17 HW AND IDB INCONSISTENT18 INTERNAL CONFIGURATION FAILED19 INDOOR TEMPERATURE ABOVE SAFE RANGE20 INDOOR TEMPERATURE BELOW SAFE RANGE

CF, INTERNAL FAULT MAP CLASS 2A

0 RESET, FAILED RESTART ATTEMPT1 RESET, POWER ON2 RESET, SWITCH3 RESET, WATCHDOG4 RESET, SW FAULT5 RESET, RAM FAULT6 RESET, INTERNAL FUNCTION CHANGE7 RXDA AMPLIFIER CURRENT FAULT.8 VSWR LIMITS EXCEEDED9 POWER LIMITS EXCEEDED10 DXU OPTIONAL EEPROM CHECKSUM FAULT11 ALNA FAULT12 RX MAXGAIN/MINGAIN VIOLATED13 TIMING UNIT VCO AGEING14 CDU SUPERVISION/COMMUNICATION LOST15 VSWR/ OUTPUT POWER SUPERVISION LOST16 INDOOR TEMPERATURE OUT OF NORMAL CONDITIONAL RANGE17 INDOOR HUMIDITY18 DC VOLTAGE OUT OF RANGE19 POWER SYSTEM IN STAND-ALONE MODE20 EXTERNAL POWER FAULT21 INTERNAL POWER CAPACITY REDUCED22 BATTERY BACKUP CAPACITY REDUCED23 FAN CAPACITY REDUCED/ CLIMATE CAPACITY REDUCED24 COOLER CAPACITY REDUCED/ CU HW FAULT25 HEATER CAPACITY REDUCED

26 CLIMATE SENSOR FAULT27 SYSTEM VOLTAGE SENSOR FAULT28 A/D CONVERTER FAULT29 VARISTOR FAULT30 LOCAL BUS FAULT31 HIGH-FREQUENCY SOFTWARE FAULT32 NON-VOLATILE MEMORY CORRUPTED33 RX DIVERSITY LOST34 OUTPUT VOLTAGE FAULT35 OPTIONAL SYNCHRONISATION SOURCE36 RU DATABASE CORRUPTED37 CIRCUIT BREAKER TRIPPED38 DEFAULT VALUES USED39 RX CABLE DISCONNECTED40 RESET, DXU LINK LOST41 LOST COMMUNICATION TO TRU42 LOST COMMUNICATION TO ECU43 INTERNAL CONFIGURATION FAILED44 INDOOR TEMPERATURE ABOVE NORMAL CONDITIONAL RANGE45 INDOOR TEMPERATURE BELOW NORMAL CONDITIONAL RANGE46 DB PARAMETER FAULT47 AUXILIARY EQUIPMENT FAULT

SO CF, REPLACEMENT UNIT MAP

0 DXU1 ECU2 MICRO RBS5 CDU6 BFU7 PSU8 CDU_COS9 BDM10 ACCU11 ACTIVE COOLER / HEAT EXCHANGER EXTERNAL FAN12 ALNA A13 ALNA B14 BATTERY15 FAN16 HEATER17 HEAT EXCHANGER EXTERNAL FAN18 HEAT EXCHANGER INTERNAL FAN19 HUMIDITY SENSOR20 TMA/CM21 TEMPERATURE SENSOR22 CDU HLOUT HLIN CABLE23 CDU RX IN CABLE24 CU25 DU26 FU27 FU CU PFWD CABLE28 FU CU PREFL CABLE29 CAB HLIN CABLE30 CDU BUS31 ENVIRONMENT

32 LOCAL BUS33 POWER COMMUNICATION LOOP34 RX ANTENNA A35 RX ANTENNA B36 TIMING BUS37 TX ANTENNA A38 TX ANTENNA B39 X BUS40 ANTENNA

SO TRXC, EXTERNAL CONDITION MAP CLASS 1

4 L/R SWI (TRU IN LOCAL MODE)5 L/R TI (LOCAL TO REMOTE WHILE LINK LOST)

SO TRXC, INTERNAL FAULT MAP CLASS 1A

0 RESET, FAILED RESTART ATTEMPT1 RESET, POWER ON2 RESET, SWITCH3 RESET, WATCHDOG4 RESET, SW FAULT5 RESET, RAM FAULT6 RESET, INTERNAL FUNCION CHANGE7 ASTRA FAULT8 TIMING RECEPTION FAULT9 SIGNALING PROCESSING FAULT10 TORA DANNIE COMMUNICATION FAULT11 DSP CPU COMMUNICATION FAULT12 TERRESTRIAL TRAFFIC CHANNEL FAULT13 RF LOOP TEST FAULT14 RU DATA BASE CORRUPTED15 XBUS COMMUNICATION FAULT16 INITIATION FAULT17 X-INTERFACE FAULT18 DSP FAULT19 RESET, DXU LINK LOST20 HW AND IDB INCONSISTENT21 INTERNAL CONFIGURATION FAILED22 VOLTAGE SUPPLY FAULT

SO TRXC, INTERNAL FAULT MAP CLASS 1B

0 CDU NOT USABLE1 INDOOR TEMP OUT OF SAFE RANGE3 DC VOLTAGE OUT OF RANGE4 INDOOR TEMP ABOVE SAFE RANGE5 INDOOR TEMP BELOW SAFE RANGE

SO TRXC, INTERNAL FAULT MAP CLASS 2A

0 RX CABLE DISCONNECTED

1 RX EEPROM CHECKSUM FAULT2 RX CONFIG TABLE CHECKSUM FAULT3 RX SYNTHESIZER UNLOCKED4 RX INTERNAL VOLTAGE FAULT5 ASTRA DIXIE COMMUNICATION FAULT6 ASTRA TRACY COMMUNICATION FAULT7 TX EEPROM CHECKSUM FAULT8 TX CONFIG TABLE CHECKSUM FAULT9 TX SYNTHESIZER UNLOCKED10 TX INTERNAL VOLTAGE FAULT11 TX HIGH TEMPERATURE12 TX OUTPUT POWER LIMITS EXCEEDED13 TX SATURATION14 VOLTAGE SUPPLY FAULT15 VSWR/OUTPUT POWER SUPERVISION LOST16 NON-VOLATILE MEMORY CORRUPTED17 LOADFILE MISSING IN TRU18 DSP FAULT19 HIGH FREQUENCY SOFTWARE FAULT20 RX INITIATION FAULT21 TX INITIATION FAULT22 CDU-BUS COMMUNICTION FAULT23 DEFAULT VALUES USED25 TX MAX POWER RESTRICTED26 DB PARAMETER FAULT

SO TRXC, REPLACEMENT UNIT MAP

0 TRU2 MICRO RBS10 CDU TO TRU PFWD CABLE11 CDU TO TRU PREFL CABLE12 CDU TO TRU RXA CABLE13 CDU TO TRU RXB CABLE

AO CON, EXTERNAL CONDITION MAP CLASS 1

8 LAPD QUEUE CONGESTION

AO CON, EXTERNAL CONDITION MAP CLASS 2

8 LAPD QUEUE CONGESTION

AO TS, EXTERNAL CONDITION MAP CLASS 1

3 TRA (REMOTE TRANSCODER COM. LOST)

AO TF, INTERNAL FAULT MAP CLASS 1B

0 OPTIONAL SYNCHRONIZATION SOURCE1 DXU-OPT EEPROM CHECKSUM FAULT

AO TF, EXTERNAL CONDITION MAP CLASS 1

1 PCM SYNC

AO TF, EXTERNAL CONDITION MAP CLASS 2

1 PCM SYNC

AO TX, INTERNAL FAULT MAP CLASS 1A

0 TX OFFENDING

AO TX, INTERNAL FAULT MAP CLASS 1B

0 CU NOT USABLE1 CDU VSWR LIMITS EXCEEDED2 CDU OUTPUT POWER LIMITS EXCEEDED4 TX ANTENNA VSWR LIMITS EXCEEDED6 TX EEPROM CHECKSUM FAULT7 TX CONFIG TABLE CHECKSUM FAULT8 TX SYNTHESIZER A/B UNLOCKED9 TX SYNTHESIZER C UNLOCKED10 ASTRA TRACY COMMUNICATION FAULT11 TX INTERNAL VOLTAGE FAULT12 TX HIGH TEMPERATURE13 TX OUTPUT POWER LIMITS EXCEEDED14 TX TX SATURATION15 VOLTAGE SUPPLY FAULT16 POWER UNIT6 NOT READY17 TX INITIATION FAULT18 CU HW FAULT19 CU SW LOAD/START FAULT20 CU INPUT POWER FAULT21 CU PARK FAULT22 VSWR/OUTPUT POWER SUPERVISION LOST23 CU RESET, POWER ON24 CU RESET, COMMUNICATION FAULT25 CU RESET, WATCHDOG26 CU FINE TUNING FAULT27 TX MAX POWER RESTRICTED47 TX AUXILIARY EQUIPMENT FAULT

AO RX, INTERNAL FAULT MAP CLASS 1B

0 RXDA AMPLIFIER CURRENT FAULT1 ALNA FAULT3 RX EEPROM CHECKSUM FAULT4 RX CONFIG TABLE CHECKSUM FAULT5 RX SYNTHESIZER A/B UNLOCKED6 RX SYNTHESIZER C UNLOCKED7 ASTRA DIXIE COMMUNICATION FAULT8 RX INTERNAL VOLTAGE FAULT9 RX CABLE DISCONNECTED10 RX INITIATION FAULT11 CDU OUTPUT VOLTAGE FAULT

47 RX AUXILIARY EQUIPMENT FAUL

8-R10 BTS FAULT CODE LIST

=====SO CF, Internal Fault Map Class 1A=====Fault No Fault typeCF-1A 0CF-1A 1 Reset, Power OnCF-1A 2 Reset, SwitchCF-1A 3 Reset, WatchdogCF-1A 4 Reset, SW FaultCF-1A 5 Reset, RAM FaultCF-1A 6 Reset, Internal Function ChangeCF-1A 7 XBus FaultCF-1A 8 Timing Unit VCO FaultCF-1A 9 (R9 only) Time Distribution FaultCF-1A 9 (R10 only) Timing Bus FaultCF-1A 10 Indoor Temp Out of Safe RangeCF-1A 11CF-1A 12 DC Voltage Out Of RangeCF-1A 13CF-1A 14 Bus FaultCF-1A 15 IDB CorruptedCF-1A 16 RU Data Base CorruptedCF-1A 17 HW And IDB InconsistentCF-1A 18 Internal Configuration FailedCF-1A 19CF-1A 20CF-1A 21 HW FaultCF-1A 22 Air Time Counter LostCF-1A 23 (R10 only) Time Distribution FaultCF-1A .CF-1A .CF-1A 47

=====SO CF, Internal Fault Map Class 1B=====Not used.=====SO CF, Internal Fault Map Class 2A=====Fault No Fault TypeCF-2A 0CF-2A 1 Reset, Power OnCF-2A 2 Reset, SwitchCF-2A 3 Reset, WatchdogCF-2A 4 Reset, SW FaultCF-2A 5 Reset, RAM FaultCF-2A 6 Reset, Internal Function ChangeCF-2A 7 RX Internal Amplifier FaultCF-2A 8 VSWR Limits ExceededCF-2A 9 Power Limits ExceededCF-2A 10 DXU-Opt EEPROM Checksum FaultCF-2A 11CF-2A 12 RX Maxgain/Mingain ViolatedCF-2A 13 Timing Unit VCO AgeingCF-2A 14 (R9 only) Supervision/Communication LostCF-2A 14 (R10 only) CDU Supervision/Communication LostCF-2A 15 VSWR/Output Power Supervision Lost

CF-2A 16 Indoor Temp Out Of Normal Conditional RangeCF-2A 17 Indoor HumidityCF-2A 18 DC Voltage Out Of RangeCF-2A 19 Power and Climate System in Standalone ModeCF-2A 20CF-2A 21 Internal Power Capacity ReducedCF-2A 22 Battery Backup Capacity ReducedCF-2A 23 Climate Capacity ReducedCF-2A 24 HW FaultCF-2A 25 Loadfile Missing in DXU or ECUCF-2A 26 Climate Sensor FaultCF-2A 27 System Voltage Sensor FaultCF-2A 28 A/D Converter FaultCF-2A 29 Varistor FaultCF-2A 30 Bus FaultCF-2A 31 High Frequency of Software FaultCF-2A 32 Non-Volatile Memory CorruptedCF-2A 33 RX Diversity LostCF-2A 34 Output Voltage FaultCF-2A 35 Optional Synchronization SourceCF-2A 36 RU Data Base CorruptedCF-2A 37 Circuit Breaker Tripped or Fuse BlownCF-2A 38 Default Values UsedCF-2A 39 RX Cable DisconnectedCF-2A 40 Reset, DXU Link LostCF-2A 41 Lost communication to TRUCF-2A 42 Lost communication to ECUCF-2A 43 Internal Configuration FailedCF-2A 44 ESB Distribution FailureCF-2A 45 High TemperatureCF-2A 46 DB parameter faultCF-2A 47 Antenna Hopping FailureCF-2A 48 GPS Synch FaultCF-2A 49 Battery Backup time shorter than expectedCF-2A 50 RBS running on batteryCF-2A 51 TMA Supervision/Communications LostCF-2A 52 CXU Supervision/Communication LostCF-2A 53 HW and IDB InconsistentCF-2A .CF-2A .CF-2A 95

=====SO CF, External Condition Map Class 1=====Fault No Fault TypeEXT CF-1B 4 L/R SWI (BTS In Local Mode)EXT CF-1B 5 L/R TI (Local to Remote while Link Lost)

=====SO CF, External Condition Map Class 2=====Fault No Fault TypeEXT CF-2A 9 RBS DOOR (RBS cabinet door open)EXT CF-2A 10 MAINS FAIL (External power source fail)EXT CF-2A 11 ALNA/TMA FaultEXT CF-2A 12 ALNA/TMA DegradedEXT CF-2A 13 Auxiliary Equipment FaultEXT CF-2A 14 Battery Backup External Fuse FaultEXT CF-2A 15

=====SO CF, Replacement Unit Map=====No Replacement UnitCF RU 0 DXU or IXUCF RU 1 ECUCF RU 2 MICRO RBSCF RU 3 Y LINKCF RU 4 TIMCF RU 5 CDUCF RU 6 CCUCF RU 7 PSUCF RU 8 (R9 only)CF RU 8 (R10 only) BFUCF RU 9 (R9 only) BDM or BFU or BFU Fuse or Circuit BreakerCF RU 9 (R10 only) BDMCF RU 10 ACCUCF RU 11 ACTIVE COOLERCF RU 12 ALNA/TMA ACF RU 13 ALNA/TMA BCF RU 14 BATTERYCF RU 15 FANCF RU 16 HEATERCF RU 17 HEAT EXCHANGER EXT FANCF RU 18 HEAT EXCHANGER INT FANCF RU 19 HUMIDITY SENSORCF RU 20 TMA CMCF RU 21 (R9 only) TEMPERATURE SENSOR or ACTIVE COOLER FANCF RU 21 (R10 only) TEMPERATURE SENSORCF RU 22 CDU HLOUT HLIN CABLECF RU 23 CDU RX IN CABLECF RU 24 CUCF RU 25 DUCF RU 26 FUCF RU 27 (R9 only) FU CU PFWD CABLE or CDU CDU PFWD CABLECF RU 27 (R10 only) FU CU PFWD CABLECF RU 28 (R9 only)FU CU PREFL CABLE or CDU CDU PREFL CABLECF RU 28 (R10 only) FU CU PREFL CABLECF RU 29 CAB HLIN CABLECF RU 30 (R9 only) CDU BUS/IOM BUSCF RU 30 (R10 only) CDU BUSCF RU 31 ENVIRONMENTCF RU 32 LOCAL BUSCF RU 33 EPC BUS / POWER COMMUNICATION LOOPCF RU 34 IDBCF RU 35CF RU 36 TIMING BUSCF RU 37 CDU CXU RXA CABLECF RU 38 CDU CXU RXB CABLECF RU 39 XBUSCF RU 40 ANTENNACF RU 41 PSU DC CABLECF RU 42 CXUCF RU 43 FLASH CARDCF RU 44CF RU 45 BATTERY TEMP SENSORCF RU 46 FCUCF RU 47 TMA_CM CABLECF RU 48 GPS RECEIVER or LMU

CF RU 49 GPS RECEIVER DXU CABLECF RU 50 ACTIVE COOLER FANCF RU 51 BFU Fuse or Circuit BreakerCF RU 52 CDU CDU PFWD CABLECF RU 53 CDU CDU PREFL CABLECF RU 54 IOM BUSCF RU 55 ASU RXA UNITS OR CABLESCF RU 56 ASU RXB UNITS OR CABLESCF RU 57 ASU CDU RXA CABLECF RU 58 ASU CDU RXB CABLE95

=====SO TRXC, Internal Fault Map Class 1A=====Fault No Fault TypeTRX-1A 0TRX-1A 1 Reset, Power OnTRX-1A 2 Reset, SwitchTRX-1A 3 Reset, WatchdogTRX-1A 4 Reset, SW FaultTRX-1A 5 Reset, RAM FaultTRX-1A 6 Reset, Internal Function ChangeTRX-1A 7TRX-1A 8 Timing Reception FaultTRX-1A 9 Signal Processing FaultTRX-1A 10 RX Communication FaultTRX-1A 11 DSP CPU Communication FaultTRX-1A 12 Terrestrial Traffic Channel FaultTRX-1A 13 RF Loop Test FaultTRX-1A 14 RU Data Base CorruptedTRX-1A 15 XBus Communication FaultTRX-1A 16 Initiation FaultTRX-1A 17 X-Interface FaultTRX-1A 18 DSP FaultTRX-1A 19 Reset, DXU Link LostTRX-1A 20 HW And IDB InconsistentTRX-1A 21 Internal Configuration FailedTRX-1A 22 Voltage Supply FaultTRX-1A 23 Air Time Counter LostTRX-1A 24 High TemperatureTRX-1A 25 TX/RX Communication FaultTRX-1A 26 Radio Control System LoadTRX-1A 27 Traffic Lost DownlinkTRX-1A 28 Traffic Lost UplinkTRX-1A 29 Y Link Communication HW FaultTRX-1A 30 DSP RAM Soft Error..TRX-1A 47

=====SO TRXC, Internal Fault Map Class 1B=====Fault No Fault TypeTRX-1B 0 CDU/Combiner Not UsableTRX-1B 1 Indoor Temp Out Of Safe RangeTRX-1B 2TRX-1B 3 DC Voltage Out Of RangeTRX-1B 4TRX-1B 5

TRX-1B 6TRX-1B 7 TX Address ConflictTRX-1B 8 Y Link Communication FaultTRX-1B 9 Y Link Communication LostTRX-1B 10 Timing Reception Fault..TRX-1B 47

=====SO TRXC, Internal Fault Map Class 2A=====Fault No Fault TypeTRX-2A 0 RX Cable DisconnectedTRX-2A 1 RX EEPROM Checksum FaultTRX-2A 2 RX Config Table Checksum FaultTRX-2A 3 RX Synthesizer UnlockedTRX-2A 4 RX Internal Voltage FaultTRX-2A 5 RX Communication FaultTRX-2A 6 TX Communication FaultTRX-2A 7 TX EEPROM Checksum FaultTRX-2A 8 TX Config Table Checksum FaultTRX-2A 9 TX Synthesizer UnlockedTRX-2A 10 TX Internal Voltage FaultTRX-2A 11 TX High TemperatureTRX-2A 12 TX Output Power Limits ExceededTRX-2A 13 TX SaturationTRX-2A 14 Voltage Supply FaultTRX-2A 15 VSWR/Output Power Supervision LostTRX-2A 16 Non-Volatile Memory CorruptedTRX-2A 17 Loadfile Missing in TRUTRX-2A 18 DSP FaultTRX-2A 19 High Frequency of Software FaultTRX-2A 20 RX Initiation FaultTRX-2A 21 TX Initiation FaultTRX-2A 22 CDU-Bus Communication FaultTRX-2A 23 Default Values UsedTRX-2A 24TRX-2A 25 TX Max Power RestrictedTRX-2A 26 DB parameter faultTRX-2A 27TRX-2A 28TRX-2A 29 Power Amplifier FaultTRX-2A 30 CPU High TemperatureTRX-2A 31TRX-2A 32 RX High TemperatureTRX-2A 33 Inter TRX Communication FaultTRX-2A 34TRX-2A 35 Traffic Burst InhibitTRX-2A 36 RX Filter Loadfile Checksum FaultTRX-2A 37 RX Internal Amplifier FaultTRX-2A 38 Climate Capacity ReducedTRX-2A 39 RF-loop Test Fault, Degraded RXTRX-2A 40 Memory FaultTRX-2A .TRX-2A .TRX-2A 47

=====SO TRXC, External Condition Map Class 1=====Fault No Fault TypeEXT TRX-1B 4 L/R SWI (TRU In Local Mode)EXT TRX-1B 5 L/R TI (Local to Remote while Link Lost)

===== SO TRXC, External Condition Map Class 2=====Not used.

=====SO TRXC, Replacement Unit Map=====No RUTRX RU 0 TRU, dTRU or RRUTRX RU 1TRX RU 2 MICRO RBSTRX RU 3 CXU TRU RXA CABLETRX RU 4 CXU TRU RXB CABLETRX RU 5TRX RU 6TRX RU 7TRX RU 8TRX RU 9TRX RU 10 CDU TO TRU PFWD CABLETRX RU 11 CDU TO TRU PREFL CABLETRX RU 12 CDU TO TRU RXA CABLETRX RU 13 CDU TO TRU RXB CABLETRX RU .TRX RU .TRX RU 47TRX RU

=====AO CON, Internal Fault Map Class 1A=====Not used.

=====AO CON, Internal Fault Map Class 1B=====Not used.

=====AO CON, Internal Fault Map Class 2A=====Not used.

=====AO CON, External Condition Map Class 1=====Fault No Fault TypeEXT CON-1B 8 LAPD Q CG (LAPD Queue Congestion)

=====AO CON, External Condition Map Class 2=====Fault No Fault TypeEXT CON-2B 8 LAPD Q CG (LAPD Queue Congestion)

=====AO CON, Replacement Unit Map=====Not used. See Replacement Unit Map for SO CF forpossible HW causing the fault.

=====AO IS=====AO IS is not supervised.=====AO RX, Internal Fault Map Class 1A=====Not used.

=====AO RX, Internal Fault Map Class 1B=====

Fault No Fault typeRX-1B 0 RX Internal Amplifier FaultRX-1B 1 ALNA/TMA FaultRX-1B 2RX-1B 3 RX EEPROM Checksum FaultRX-1B 4 RX Config Table Checksum FaultRX-1B 5 RX Synthesizer A/B UnlockedRX-1B 6 RX Synthesizer C UnlockedRX-1B 7 RX Communication FaultRX-1B 8 RX Internal Voltage FaultRX-1B 9 RX Cable DisconnectedRX-1B 10 RX Initiation FaultRX-1B 11 CDU Output Voltage FaultRX-1B 12 TMA CM Output Voltage FaultRX-1B 13RX-1B 14 CDU Supervision/Communication FaultRX-1B 15 RX High TemperatureRX-1B 16RX-1B 17 TMA Supervision FaultRX-1B 18 TMA Power Distribution FaultRX-1B 19 RX Filter Loadfile Checksum FaultRX-1B .RX-1B .RX-1B 47 RX Auxiliary Equipment Fault

=====AO RX, Internal Fault Map Class 2A=====Fault No Fault typeRX-2A 0 CXU Supervision/Communication FaultRX-2A 1 RX Path Lost on A receiver sideRX-2A 2 RX Path Lost on B receiver side..RX-2A 47

=====AO RX, External Condition Map Class 1====Not used.

=====AO RX, External Condition Map Class 2=====Not used.

=====AO RX, Replacement Unit Map=====Not used. See Replacement Unit Map for SO CF and SOTRXC for possible HW causing the fault.

=====AO TF, Internal Fault Map Class 1A=====Not used.

=====AO TF, Internal Fault Map Class 1B=====Fault No Fault TypeTF-1B 0 Optional Synchronization SourceTF-1B 1 DXU-Opt EEPROM Checksum FaultTF-1B 2 GPS Synch Fault..TF-1B 47

=====AO TF, Internal Fault Map Class 2A=====

Fault No Fault TypeTF-2A 0 Frame Start Offset Fault..TF-2A 47

=====AO TF, External Condition Map Class 1=====Fault No Fault TypeEXT TF-1B 0 EXT SYNCH (No Usable External Reference)EXT TF-1B 1 PCM SYNCH (No Usable PCM-Reference)

=====AO TF, External Condition Map Class 2=====Fault No Fault TypeEXT TF-2B 0 EXT SYNCH (No Usable External Reference)EXT TF-2B 1 PCM SYNCH (No Usable PCM-Reference)

=====AO TF, Replacement Unit Map=====Not used. See Replacement Unit Map for SO CF forpossible HW causing the fault.

=====AO TS, External Condition Map Class 1=====Fault No Fault TypeEXT TS-1B 3 TRA/PCU (Remote Transcoder/PCU Com. Lost)

=====AO TX, Internal Fault Map Class 1A=====Fault No Fault typeTX-1A 0 TX Offending

=====AO TX, Internal Fault Map Class 1B=====Fault No Fault typeTX-1B 0 CU/CDU Not UsableTX-1B 1 CDU/Combiner VSWR Limits ExceededTX-1B 2 CDU Output Power Limits ExceededTX-1B 3TX-1B 4 TX Antenna VSWR Limits ExceededTX-1B 5TX-1B 6 TX EEPROM Checksum FaultTX-1B 7 TX Config Table Checksum FaultTX-1B 8 TX Synthesizer A/B UnlockedTX-1B 9 TX Synthesizer C UnlockedTX-1B 10 TX Communication FaultTX-1B 11 TX Internal Voltage FaultTX-1B 12 TX High TemperatureTX-1B 13 TX Output Power Limits ExceededTX-1B 14 TX SaturationTX-1B 15TX-1B 16TX-1B 17 TX Initiation FaultTX-1B 18 CU/CDU HW FaultTX-1B 19 CU/CDU SW Load/Start FaultTX-1B 20 CU/CDU Input Power FaultTX-1B 21 CU/CDU Park FaultTX-1B 22 VSWR/Output Power Supervision LostTX-1B 23 CU/CDU Reset, Power OnTX-1B 24 CU Reset, Communication FaultTX-1B 25 CU/CDU Reset, Watchdog

TX-1B 26 CU/CDU Fine Tuning FaultTX-1B 27 TX Max Power RestrictedTX-1B 28 CDU High TemperatureTX-1B 29TX-1B 30 TX CDU Power Control FaultTX-1B 31 Power Amplifier FaultTX-1B 32 TX Low TemperatureTX-1B 33 CDU-Bus Communication Fault..TX-1B 47 TX Auxiliary Equipment Fault=====AO TX, Internal Fault Map Class 2A=====Fault No Fault TypeTX-2A 0 TX Diversity Fault..47

^^^^^ LOGICAL RU ^^^^^A unit which can be refered to but is not a singlepysical unit. There are tree different kinds of logical RUs:1. BUSSES -XBUS -LOCAL BUS -TIMING BUS -CDU BUS -POWER COMMUNICATION LOOP2. ANTENNAS -RX A -RX B -TX A -TX B3. ENVIRONMENT -TEMPERATURE

^^^^^^ BITMAP FOR RXELP:MO=; ^^^^^^^^^^^^^^^^^^000000000001 0000000000002 1000000000004 2000000000008 3000000000010 4000000000020 5000000000040 6000000000080 7000000000100 8000000000200 9000000000400 10000000000800 11000000001000 12000000002000 13000000004000 14000000008000 15000000010000 16000000020000 17000000040000 18000000080000 19000000100000 20

000000200000 21000000400000 22000000800000 23 000001000000 24000002000000 25000004000000 26000008000000 27000010000000 28000020000000 29000040000000 30000080000000 31000100000000 32000200000000 33000400000000 34000800000000 35001000000000 36002000000000 37004000000000 38008000000000 39010000000000 40020000000000 41040000000000 42080000000000 43100000000000 44200000000000 45400000000000 46800000000000 47

^^^^^^^^^^^^^^^^ DIGITAL PATH FAULTS ^^^^^^^^^^^^^^^DIP fault 1 Alarm indication signal AISDIP fault 2 Loss of frame alignmentDIP fault 3 Excessive error rateDIP fault 4 Alarm indication from the remote endDIP fault 5 Alarm indication signal in time slot 16DIP fault 6 Loss of multiframe alignmentDIP fault 7 Alarm ind. from remote end signalling equipmentDIP fault 8 Alarm indication signal ALL1DIP fault 9 Loss of CRC multiframe alignmentDIP fault 10 Consectutive severely errrored seconds

^^^^^^^^^^^ RADIO X-CEIVER ADMINISTRATION ^^^^^^^^^^^^ MANAGED OBJECT STATUSBTS: Last known state of the MO in the BTSRES= MO is in state RESETSTA= STARTEDDIS= DISABLEDENA= ENABLED

BITMAP for BLO (Blocking origin of automatic blocking)HEX BITxxx1 0 AP object blocked from own superv. perm.xxx2 1 AT object blocked from own superv. temp.xxx4 2 AS object blocked due to fault suspectedxxx8 3 TG object blocked from TGxx10 4 TRXC object blocked from TRXCxx20 5 TGC object blocked from TGCxx40 6 OML object blocked from OML

xx80 7 X sparex100 8 LMT obj. blo. due to local maint. activitiesx200 9 CF object blocked from CFx400 10 LOM object blocked from due to local modex800 11 LOOP obj. blo. from due to loop test failure

BITMAP for BLA (Blocking origin of blocking due to action not completed)HEX BITxxx1 0 BNU obj. needs reset & uncond. load or reset & load. in progr.xxx2 1 BNR obj. needs reset & load check or reset & load. in progr.xxx4 2 BNL obj. needs reset and load check or loading in progressxxx8 3 BNP obj. needs polling or polling in progressxx10 4 BNT obj. needs testing or testing in progressxx20 5 BNI obj. needs intermittent test or interm. test in progr.xx40 6 BND obj. needs updating of MO dataxx80 7 BNS obj. needs to be startedx100 8 BNM obj. needs to be manually deblocked (BTS initiated)x200 9 BNO obj. needs loop test or loop loop test in progress

BITMAP for LMO (Blocking origin of logical managed object TS)HEX BITxx20 5 CRN LTS blocked due to creation in progressxx40 6 ENA LTS blocked due to not enabledxx80 7 Xx100 8 MO LTS blocked from TSx200 9 LTF LTS blocked from LTFx400 10 RSL RSL blocked from RSLx800 11 DEV LTS blocked from speech/data device1000 12 X2000 13 SYNCB LTS blo. due to sync. fault in BTS4000 14 X8000 15 CHG blocked due to change

BITMAP for LMO (Blocking origin of logical managed object TF)HEX BITxx20 5 CRN LTF blocked due to creation in progress xx40 6 ENA LTF blocked due to not enabled xx80 7 Xx100 8 MO LTF blocked from TF

9-Cell, TG, MO, RHDEV, RBLT, RP relation:

- Find all connected TG's and cells

RXTCP:MOTY=RXOTG;

- Find the TG number of a cell.

RXTCP:CELL=cell,MOTY=RXOTG;

- Find the RHDEV device.

RXMDP:MO=RXOTRX-x-y; (x=TG number, y=any TRX number 0,2 etc...)

- Find the RPG number

RADRP:DEV=RHDEV-z; (z=RHDEV number)

- Find the RBLT devices

RXAPP:MO=RXOTG-x;

10-Collect data according:

COMMAND: RXMSP:MO=RXOTG-X, SUBORD; COMMAND: RXAPP:MO=RXOTG-X; COMMAND: RXELP:MO=RXOTG-X; COMMAND: RXMFP:MO=RXOTG-X, SUBORD; COMMAND: RXMOP:MO=RXOTG-X; ! REPEAT FRO ALL MOs UNDER THE tg ! COMMAND: RXTCP:MO=RXOTG-X; COMMAND: RXCDP:MO=RXOTG-X;

1- Use command RXMDP to find the RHDEV device associated to the MO.

2- Use command RADRP to find the RP controlling that RHDEV.

3- If the RP is the same, then the problem lies in the TRH. 1- Take the BTS out of service:

COMMAND: RXBLI:MO=RXOTG-X, SUBORD,FORCE; COMMAND: RXESE:MO=RXOTG-X, SUBORD;

2- Put the BTS into service.

COMMAND: RXESI:MO=RXOTG-X, SUBORD; COMMAND: RXBLE:MO=RXOTG-X, SUBORD;

1-PRINTOUT CELL STATUSCommand: RLSTP:CELL=ALL;2-PRINTOUT CELL RESOURCESCommand:RLCRP:CELL=ALL; RLCRP:CELL=ALL,DETAIL;3-PRINTOUT RADIO X-CEIVER ADMINISTRATION MANAGED OBJECT DATA

Command:

RXMOP:MOTY=RXOTG; RXMOP:MOTY=RXOTRX;

4-PRINTOUT RADIO X-CEIVER ADMINISTRATION MANAGED OBJECT STATUS Command:For : RBS 2000RXMSP:MOTY=RXOTG;

RXMSP:MOTY=RXOTRX;RXMSP:MOTY=RXOCF;RXMSP:MOTY=RXOTF;RXMSP:MOTY=RXOTX;RXMSP:MOTY=RXORX;RXMSP:MOTY=RXOTS;1.1.1 Print TRH Device Load table Command:RAHHP:SNT=ALL ,(High);

1.1.2 Print RADIO CONTROL ADMINISTRATION TRH LOAD MONITORING AND DISTRIBUTION DATA. :RAHDP;

1.1.3 PRINTOUT OF THE TRH EVENT LOG.Command: RAHEP;

1.1.4 PRINTOUT OF TRH LOAD THRESHOLD DATA Command: RAHLP;

1.1.5 PRINTOUT TRH LOAD PERIODIC DISTRIBUTION STATE. Command: RAHPP;

1.1.6 PRINTOUT OF THE TRH DEVICE LOAD TABLE. Command: RAHTP:SNT=ALL;

11-To make a site operational follow the following instructions:

RXESI:MO=RXOTG-x;

RXBLE:MO=RXOTG-x;

RXESI:MO=RXOCF-x;

RXBLE:MO=RXOCF-x;

RXESI:MO=RXOIS-x;

RXBLE:MO=RXOIS-x;

RXESI:MO=RXOTF-x;

RXBLE:MO=RXOTF-x;

RXESI:MO=RXOCON-x;

RXBLE:MO=RXOCON-x;

RXESI:MO=RXODP-x-0;

RXBLE:MO=RXODP-x-0;

RXESI:MO=RXOTRX-x-0&&-n;

RXBLE:MO=RXOTRX-x-0&&-n;

RXESI:MO=RXOTX-x-0&&-n;

RXBLE:MO=RXOTX-x-0&&-n;

RXESI:MO=RXORX-x-0&&-n;

RXBLE:MO=RXORX-x-0&&-n;

RXESI:MO=RXOTS-x-0-0&&-7; !This needs to be done for all the connected TRX's

RXBLE:MO=RXOTS-x-0-0&&-7; !This needs to be done for all the connected TRX's

RLSTC:CELL=cell, STATE=ACTIVE;

SIMILARLY FOR BRINGING A SITE OUT OF SERVICE

RLSTC:CELL=cell,STATE=HALTED;

RXBLI:MO=RXOTS-x-0-0&&-7; !This needs to be done for all the connected TRX's

RXESE:MO=RXOTS-x-0-0&&-7; !This needs to be done for all the connected TRX's

RXBLI:MO=RXORX-x-0&&-n;

RXESE:MO=RXORX-x-0&&-n;

RXBLI:MO=RXOTX-x-0&&-n;

RXESE:MO=RXOTX-x-0&&-n;

RXBLI:MO=RXOTRX-x-0&&-n;

RXESE:MO=RXOTRX-x-0&&-n;

RXBLI:MO=RXODP-x-0;

RXESE:MO=RXODP-x-0;

RXBLI:MO=RXOCON-x;

RXESE:MO=RXOCON-x;

RXBLI:MO=RXOIS-x;

RXESE:MO=RXOIS-x;

RXBLI:MO=RXOTF-x;

RXESE:MO=RXOTF-x;

RXBLI:MO=RXOCF-x;

RXESE:MO=RXOCF-x;

RXBLI:MO=RXOTG-x;

RXESE:MO=RXOTG-x;

12-Cell into Service & out of service:

12.1Cell into Service

When a cell is to be taken into service the MO's must to be loaded in a specific hiercical order. If a higher level fails you will not be successful in taking the next level into service.The order in which the managed objects are brought into service in BTS Logical Model G01 is TG before the corresponding TRXC, TX and TF; and TRXC before the corresponding TS and RX. G01 is not used in the US market.The order in which the managed objects are brought into service in BTS Logical Model G12 is TG before the corresponding CF; and CF before thecorresponding IS, CON, TRXC, TF and DP; and TRXC before the corresponding RX, TX and TS.

Example for BTS Logical Model G12 (RBS2000)

------------

RXESI:MO=RXOTG-511;

RXESI:MO=RXOCF-511;

RXESI:MO=RXODP-511-0;

RXESI:MO=RXOCON-511;

RXESI:MO=RXOIS-511 & RXOTF-511;

RXESI:MO=RXOTRX-511-0&&-1;

RXESI:MO=RXORX-511-0&&-1 & RXOTX-511-0&&-1;

RXESI:MO=RXOTS-511-0-0&&-7 & RXOTS-511-1-0&&7;

Once a managed object has been brought into service it will initially be manually blocked, that is, in state COM. An attempt is then made to load the managed object. Before the cell is operational the MO's must be deblocked and the cell state changed to "active".See section blocking/deblocking of cell.

12.2 Cell out of Service

When a cell is to be taken out of service the MO's must to be blocked and taken into prepost service in a specific hiercical order. Attempts to block a higer level before subordinate MO will result in a fault code, please note that the cell and MO's must be blocked prior to taking them into prepost state.

The order in which the managed objects are brought out of service in BTS logical model G01 is TS and RX before the corresponding TRXC; and TRXC, TF and TX before the corresponding TG. G01 is not used in the US market.The order in which the managed objects is brought out of service in BTS logical model G12 is RX, TX and TS before the corresponding TRXC; and IS, CON,TRXC, TF, and DP before the corresponding CF; and CF before the corresponding TG Example for BTS Logical Model G12 (RBS2000)

RXESE:MO=RXOTS-511-0-0&&-7 & RXOTS-511-1-0&&-7;

RXESE:MO=RXOTS-511-2-0&&-7 & RXOTS-511-3-0&&-7;

RXESE:MO=RXORX-511-0&&-3 & RXOTX-511-0&&-3;

RXESE:MO=RXOTRX-511-0&&-1;

RXESE:MO=RXOTRX-511-2&&-3;

RXESE:MO=RXOIS-511 & RXOTF-511;

RXESE:MO=RXODP-511-0;

RXESE:MO=RXOCON-511;

RXESE:MO=RXOCF-511;

RXESE:MO=RXOTG-511;

12.3 Cell blocking and deblocking

The blocking/deblocking sequense should be done in the same order as described in the section Cell in or out of service. Blocking

Example for BTS Logical Model G12 (RBS2000)

Halt the cell

RLSTC:CELL=cell,STATE=HALTED;Block all MO's , defined equipment by be found issuing

RXCDP:MO=RXOTG-x;

RXBLI:MO=RXOTS-511-0-0&&-7 & RXOTS-511-1-0&&-7;

RXBLI:MO=RXORX-511-0&&-3 & RXOTX-511-0&&-3;

RXBLI:MO=RXOTRX-511-0&&-1;

RXBLI:MO=RXOIS-511 & RXOTF-511,FORCE;

RXBLI:MO=RXOCF-511;

RXBLI:MO=RXOTG-511;

RXBLI:MO=RXODP-511-0;

RXBLI:MO=RXOCON-511;

RXBLI:MO=RXOTG-511,FORCE;

DeblockingFor BTS Logical Model G12 (RBS2000) Block all MO's , defined equipment by be found by issuing

RXCDP:MO=RXOTG-x;

RXBLE:MO=RXOTG-511;

RXBLE:MO=RXODP-511-0;

RXBLE:MO=RXOCON-511;

RXBLE:MO=RXOCF-511;

RXBLE:MO=RXOIS-511 & RXOTF-511;

RXBLE:MO=RXOTRX-511-0&&-1;

RXBLE:MO=RXORX-511-0&&-3 & RXOTX-511-0&&-3;

RXBLE:MO=RXOTS-511-0-0&&-7 & RXOTS-511-1-0&&-7;

Activate the cell

RLSTC:CELL=cell,STATE=ACTIVE;

13-To know how many No. of devices connected to MSC

<STRSP:R=BSC9SPO;

DEVICE STATE SURVEYR NDV NOCC NIDL NBLO RSTATBSC9SPO 452 137 188 127 NORESEND

NDV- Total No. of devisesNOCC-Total No. of out of servise devisesNIDL-Total No. of operational devisesNBLO-Total No. of blocked devises

This command if you want to know the C7 link if active or not<C7LTP:LS=ALL;

CCITT7 LINK SET STATE

LS SPID SLC STATE INHIBST FCODE INFO2-1026 GMP1 00 ACTIVE 01 ACTIVE 02 ACTIVE

03 ACTIVE

2-1027 QUR2 00 DEACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-1059 MSC1 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE 04 ACTIVE 05 ACTIVE 06 ACTIVE 07 ACTIVE 08 ACTIVE 09 ACTIVE 10 ACTIVE 11 ACTIVE

2-1062 HLR1 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE 04 ACTIVE 05 ACTIVE 06 ACTIVE 07 ACTIVE

2-1065 MSC4 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-1067 MSC8 00 DEACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-1070 SMSC1 00 ACTIVE 01 ACTIVE

2-1071 SMSC2 00 ACTIVE 01 ACTIVE

2-1072 HLR3 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE 04 ACTIVE 05 ACTIVE 06 ACTIVE 07 ACTIVE

2-1073 MSC5 00 RESTORING 206 H'0 01 ACTIVE 02 ACTIVE

03 ACTIVE

2-1074 MSC6 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-1558 MSC2

2-2048 SOH2 00 ACTIVE 01 ACTIVE

2-2590 MSC9 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 DEACTIVE

2-4104 BSC1 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-4105 BSC2 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-4106 BSC3 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-4107 BSC4 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-4108 BSC5 00 ACTIVE 01 ACTIVE 02 ACTIVE

2-4109 BSC6 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-4110 BSC7 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE 04 ACTIVE 06 ACTIVE

2-4112 BSC9 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-4113 BSC10 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE

2-4114 BSC11 00 ACTIVE 01 ACTIVE 02 ACTIVE 03 ACTIVE 04 DEACTIVE

14-Ericsson Alarms:

To list printout of all active alarms allip;To list printout of active alarms class A1 allip:acl=a1;To get processor load plldp;To get active TCH rlcrp:cell=sab1a;To check the status rlstp:cell=sab1a;To change the status rlstc:cell=sab1a,state=halted/activeTo get cell description rldep:cell=sab1a;To get cell description of external cells 4 bsc rldep:cell=all,ext;To get frequencies or configuration rlcfp:cell=dar1a&dar1b&afm1c;To get frequencies/measure Handover rlmfp:cell=dar1a;To get the neighbours of cell rlncp:cell=dar1a;To get neighbours 4 cell with internal/external rlnrp:cell=dar1a,cellr=all,nodata;To get channels and its alarms class rlslp:cell=dar1a; To get cell locating data, means ERP of Antenna rllop:cell=dar1a;To get confg data, means the power input 2 combiner rlcpp:cell=dar1a;To get cell data if its macro/micro or umbrela rllhp:cell=dar1a;To make hopping on/off rlchc:cell=dar1a,hop=off/onTo get no. of logical channel and its alarm class rlslp:cell=dar1a;

To reset all dital path alarms 4 all cells/bsc dtqsr:dip=all,sf,df; dtqsr:dip=all,sf,es; dtqsr:dip=all,es2,ses2;

To check loop dtstp:dip=rblt12;To check quality of the loop dtqup:dip=rblt12;To block rblt dtbli:dip=rblt12;To unblock rblt dtble:dip=rblt12; dtstp:dip=all,state=abl ntstp:snt=etrblt-65;

To get status of MO (CF,TG) in BSC rxmsp:moty=rxotg;To get status of MO (CF,TG,TRX,TX,RX,TS) rxmsp:mo=rxotg-12; To get alarms status of MO rxasp:mo=rxotg-12;To get MO class fault information rxmfp:mo=rxotg-12;To get detailed info of MO (Site name and S/W) rxmop:mo=rxotg-12;To change S/W version for the MO rxmsc:mo=rxotg-12,swver=sw versionTo initiate S/W loading rxpli:mo=rxotg-12;To print error log of MO rxelp:mo=rxotg-12;To know which cell belong 2 this TG rxtcp:mo=rxotg-12;To know the cell name by using TG rxmsp:mo=rxotg-12;To get CF device information rxmdp:mo=rxocf-12;To find Tie Value rxmop:mo=rxocf-12; To block the Manage Object rxbli:mo=rxoxx-yy;To unblock the Manage Object rxble:mo=rxoxx-yy;To get rblt device no. rxapp:mo=rxotg-12;Then get etrblt no. radep:dev=rblt-400;Or stdep:dev=rblt-12;To get rblt no. of cascaded site rxtcp:cell=dar1a,moty=rxotg;To display no. of active cells in BSC saaep:sae=298;

Short Interval Statistics

Create environment imlit:spg=0;To get ststs for the cells in BSC sdtdp:rptid=101,int=15; (101 for TCH) (102 for SDCCH) (int for mnts)

MSC Commands

To get cell ID or coordination mgcep:cell=all;To initiate a cell in MSC mgcei:cell=cellname,cgi=cell id,bsc=bsc name;To create cell ID in MSC for BSC Motorola mgcei:cell=b6si29o,cgi=422-02-7010-26290,bsc=bsc6;To get BSC history syrip:survey

To trace the call in MSC ctrai:msisdn=9689466570;To trace the call in BSC rapti:dev=ralt-xxxx;To get imsi for a gsm no. mgtrp:msisdn=9689566750;To get more info of subs no. mgslp:imsi=422029689466750,all;To get the state of subs mgssp:imsi=422029689466750;To remove subs from VLR mgsre:imsi=422029689466750;To display active no. of subs. in VLR mgsvp;To see totl No of working Devises in switch strsp:r=bsc9spo; strdp:r=bsc9spo; 15-To know how many No. of devices connected to MSC strsp:r=bsc0spo; DEVICE STATE SURVEY R NDV NOCC NIDL NBLO RSTAT BSC9SPO 452 137 188 127 NORES END

NDV- Total No. of devises NOCC-Total No. of out of servise devises NIDL-Total No. of operational devises NBLO-Total No. of blocked devises

HLR Commands

To check subs. supplementary service data hgsdp:msisdn=9689512949,all;To check subs. permanent data hgsdp:msisdn=9689512949,suda;To give subs. services like TS21 hgsdc:msisdn=9689512949,sud=ts22-1; To block subs. cf in Ericsson HLR hgssi:msisdn=9689512949,ss=cfu,fnum=9351529;To deblock subs. cf in Ericsson HLR hgsse:msisdn=9689512949,ss=cfu;

BSIC& BCCHNO CGI: These value we get from Planning.

One BSIC & BSCIC shows for One cell is 2.One BSIC & BSCIC shows for Second cell is 2.One BSIC & BSCIC shows for Third cell is 2.

Shows Cell is 2+2+2…………………………………………………………

RLDEC:CELL=COL115A, CGI=413-01-20000-1151, BSIC=14, BCCHNO=520;, RLDEC:CELL=COL115B, CGI=413-01-20000-1152, BSIC=13, BCCHNO=518, RLDEC:CELL=COL115C, CGI=413-01-20000-1153, BSIC=13, BCCHNO=513,

TEI VALUE:

RXMOI:MO=RXOCF-115, TEI=62, SIG=UNCONC; RXMOI:MO=RXOCF-116, TEI=61, SIG=UNCONC; Second Casceded siteRXMOI:MO=RXOCF-117, TEI=60, SIG=UNCONC; Thiird Casceded site

RBS: 2202

Cabinet 4+4+4

One RBS cabinet TRX-0 o 5 DCP1=128,DCP2=129&130;Second RBS cabinet TRX-6 to 11 DCP1=160,DCP2=161&162;

RXMOI:MO=RXOTRX-TG-0, TEI=0, DCP1=128,DCP2=129&130, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-1, TEI=1, DCP1=131,DCP2=132&133, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-2, TEI=2, DCP1=134,DCP2=135&136, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-3, TEI=3, DCP1=137,DCP2=138&139, SIG=UNCONC;

DCP is used for Signaling while DCP2 is used for Speech.

RXMOI:MO=RXOTRX-TG-4, TEI=4, DCP1=140,DCP2=141&142, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-5, TEI=5, DCP1=143,DCP2=144&145, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-6, TEI=6, DCP1=146,DCP2=147&148, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-7, TEI=7, DCP1=149,DCP2=150&151, SIG=UNCONC;

RXMOI:MO=RXOTRX-TG-8, TEI=8, DCP1=166,DCP2=167&168, SIG=UNCONC;

RXMOI:MO=RXOTRX-TG-9, TEI=9, DCP1=169,DCP2=170&171, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-10, TEI=10, DCP1=166,DCP2=167&168, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-11, TEI=11, DCP1=169,DCP2=170&171, SIG=UNCONC;

RBS:2206

Cabinet 4+4+4

One RBS cabinet TRX-0 o 5 DCP1=128,DCP2=129&130;Second RBS cabinet TRX-6 to 11 DCP1=160,DCP2=161&162;

RXMOI:MO=RXOTRX-TG-0, TEI=0, DCP1=128,DCP2=129&130, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-1, TEI=1, DCP1=131,DCP2=132&133, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-2, TEI=2, DCP1=134,DCP2=135&136, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-3, TEI=3, DCP1=137,DCP2=138&139, SIG=UNCONC;

DCP is used for Signaling while DCP2 is used for Speech.

RXMOI:MO=RXOTRX-TG-4, TEI=4, DCP1=140,DCP2=141&142, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-5, TEI=5, DCP1=143,DCP2=144&145, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-6, TEI=6, DCP1=146,DCP2=147&148, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-7, TEI=7, DCP1=149,DCP2=150&151, SIG=UNCONC;

RXMOI:MO=RXOTRX-TG-8, TEI=8, DCP1=166,DCP2=167&168, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-9, TEI=9, DCP1=169,DCP2=170&171, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-10, TEI=10, DCP1=166,DCP2=167&168, SIG=UNCONC;RXMOI:MO=RXOTRX-TG-11, TEI=11, DCP1=1691-DEFINITION OF BSC/CELL DATA:

MGCEI:CELL=COL115A, CGI=413-1-20000-1151, BSC=BSCG2;MGCEI:CELL=COL115B, CGI=413-1-20000-1152, BSC=BSCG2;MGCEI:CELL=COL115C, CGI=413-1-20000-1153, BSC=BSCG2;

RXMOI:MO=RXOTG-115, COMB=HYB, RSITE=Biyagama, SWVER=XXXXX;

Check

rxmop:mo=rxotg-X;

SWVERACT value

RXMOI:MO=RXOCF-115, TEI=62, SIG=UNCONC;RXMOI:MO=RXOCF-116, TEI=61, SIG=UNCONC; Second Casceded siteRXMOI:MO=RXOCF-117, TEI=60, SIG=UNCONC; Thiird Casceded site

Application for 1+1+1 configuration

RXAPI:MO=RXOTG-115,DEV=RBLT-X&&-Y,DCP=1&&10;RXAPI:MO=RXOTG-116,DEV=RBLT-X&&-Y,DCP=10&&18;RXAPI:MO=RXOTG-117,DEV=RBLT-X&&-Y,DCP=21&&30;

Application for 1+1+1 configuration & can be extended to 2+2+2 for future

RXAPI:MO=RXOTG-115,DEV=RBLT-X&&-Y,DCP=1&&9;RXAPI:MO=RXOTG-116,DEV=RBLT-X&&-Y,DCP=11&&20;RXAPI:MO=RXOTG-117,DEV=RBLT-X&&-Y,DCP=21&&30;

To know TEI value

RXAPP:MO=RXOTG-X;

RXAPI:to add devices to tru.

2202 4+4+4

one RBS cabinet trx-0 to 5 dcp1=128,dcp2=129&130;second RBS cabinet trx-6 to 11 dcp1=160,dcp2=161&162;

2206

one RBS cabinet 4+4+4

trx-0 o 5 dcp1=128,dcp2=129&130;trx-6 to 11 dcp1=160,dcp2=161&162;

RXMOI:MO=RXOTRX-103-0, TEI=0, DCP1=128,DCP2=129&130, SIG=UNCONC;RXMOI:MO=RXOTRX-103-1, TEI=1, DCP1=131,DCP2=132&133, SIG=UNCONC;

RXMOI:MO=RXOTRX-103-4, TEI=4, DCP1=140,DCP2=141&142, SIG=UNCONC;RXMOI:MO=RXOTRX-103-5, TEI=5, DCP1=143,DCP2=144&145, SIG=UNCONC;

RXMOI:MO=RXOTRX-103-8, TEI=8, DCP1=166,DCP2=167&168, SIG=UNCONC;RXMOI:MO=RXOTRX-103-9, TEI=9, DCP1=169,DCP2=170&171, SIG=UNCONC;

RXMOC:MO=RXOTRX-103-0, CELL=COL103A;RXMOC:MO=RXOTRX-103-1, CELL=COL103A;

RXMOC:MO=RXOTRX-103-4, CELL=COL103B;RXMOC:MO=RXOTRX-103-5, CELL=COL103B;

RXMOC:MO=RXOTRX-103-8, CELL=COL103C;RXMOC:MO=RXOTRX-103-9, CELL=COL103C;

RXMOI:MO=RXOTX-103-0, BAND=GSM1800, MPWR=45, ANT=ANT;RXMOI:MO=RXOTX-103-1, BAND=GSM1800, MPWR=45, ANT=ANT;

RXMOI:MO=RXOTX-103-4, BAND=GSM1800, MPWR=45, ANT=ANT;RXMOI:MO=RXOTX-103-5, BAND=GSM1800, MPWR=45, ANT=ANT;

RXMOI:MO=RXOTX-103-8, BAND=GSM1800, MPWR=45, ANT=ANT;RXMOI:MO=RXOTX-103-9, BAND=GSM1800, MPWR=45, ANT=ANT;

RXMOC:MO=RXOTX-103-0, CELL=COL103A;

RXMOC:MO=RXOTX-103-1, CELL=COL103A;

RXMOC:MO=RXOTX-103-4, CELL=COL103B;RXMOC:MO=RXOTX-103-5, CELL=COL103B;

RXMOC:MO=RXOTX-103-8, CELL=COL103C;RXMOC:MO=RXOTX-103-9, CELL=COL103C;

RXMOI:MO=RXORX-103-0, BAND=GSM1800, RXD=AB, ANTA=ANTA, ANTB=ANTB;RXMOI:MO=RXORX-103-1, BAND=GSM1800, RXD=AB, ANTA=ANTA, ANTB=ANTB;

RXMOI:MO=RXORX-103-4, BAND=GSM1800, RXD=AB, ANTA=ANTA, ANTB=ANTB;RXMOI:MO=RXORX-103-5, BAND=GSM1800, RXD=AB, ANTA=ANTA, ANTB=ANTB;

RXMOI:MO=RXORX-103-8, BAND=GSM1800, RXD=AB, ANTA=ANTA, ANTB=ANTB;RXMOI:MO=RXORX-103-9, BAND=GSM1800, RXD=AB, ANTA=ANTA, ANTB=ANTB;

RXMOI:MO=RXOTS-103-0-0&&-7;RXMOI:MO=RXOTS-103-1-0&&-7;

RXMOI:MO=RXOTS-103-4-0&&-7;RXMOI:MO=RXOTS-103-5-0&&-7;

RXMOI:MO=RXOTS-103-8-0&&-7;RXMOI:MO=RXOTS-103-9-0&&-7;

!-------------------------------------------------------------------------!! ***** CONNECT TG TO CELL ***** !!-------------------------------------------------------------------------!

RXTCI:MO=RXOTG-103, CELL=COL103A, CHGR=0;RXTCI:MO=RXOTG-103, CELL=COL103B, CHGR=0;RXTCI:MO=RXOTG-103, CELL=COL103C, CHGR=0;

!97103,1!!Deblocking of MO's and Activation of Cell!!-------------------------------------------------------------------------!! ***** EQUIPMENT IN SERVICE ***** !!-------------------------------------------------------------------------!RXESI:MO=RXOTG-103, SUBORD;RXBLE:MO=RXOTG-103, SUBORD; ! THIS IS FOR LATER USE IF NEEDED !

RXESI:MO=RXOTG-103;RXESI:MO=RXOCF-103;RXESI:MO=RXOIS-103;RXESI:MO=RXOTF-103;RXESI:MO=RXODP-103-0;! RXESI:MO=RXOCON-103; LAPD CONCENTRATION NOT USED !

RXBLE:MO=RXOTG-103;RXBLE:MO=RXOCF-103;RXBLE:MO=RXOIS-103;RXBLE:MO=RXOTF-103;RXBLE:MO=RXODP-103-0;! RXBLE:MO=RXOCON-103;

RXESI:MO=RXOTRX-103-0;RXESI:MO=RXOTRX-103-1;

RXESI:MO=RXOTRX-103-4;RXESI:MO=RXOTRX-103-5;

RXESI:MO=RXOTRX-103-8;RXESI:MO=RXOTRX-103-9;

RXESI:MO=RXOTX-103-0;RXESI:MO=RXOTX-103-1;

RXESI:MO=RXOTX-103-4;RXESI:MO=RXOTX-103-5;

RXESI:MO=RXOTX-103-8;RXESI:MO=RXOTX-103-9;

RXESI:MO=RXORX-103-0;RXESI:MO=RXORX-103-1;

RXESI:MO=RXORX-103-4;RXESI:MO=RXORX-103-5;

RXESI:MO=RXORX-103-8;RXESI:MO=RXORX-103-9;

RXESI:MO=RXOTS-103-0-0&&-7;RXESI:MO=RXOTS-103-1-0&&-7;

RXESI:MO=RXOTS-103-4-0&&-7;RXESI:MO=RXOTS-103-5-0&&-7;

RXESI:MO=RXOTS-103-8-0&&-7;RXESI:MO=RXOTS-103-9-0&&-7;

RXBLE:MO=RXOTRX-103-0;RXBLE:MO=RXOTRX-103-1;

RXBLE:MO=RXOTRX-103-4;RXBLE:MO=RXOTRX-103-5;

RXBLE:MO=RXOTRX-103-8;RXBLE:MO=RXOTRX-103-9;

RXBLE:MO=RXOTX-103-0;RXBLE:MO=RXOTX-103-1;

RXBLE:MO=RXOTX-103-4;RXBLE:MO=RXOTX-103-5;

RXBLE:MO=RXOTX-103-8;RXBLE:MO=RXOTX-103-9;

RXBLE:MO=RXORX-103-0;RXBLE:MO=RXORX-103-1;

RXBLE:MO=RXORX-103-4;RXBLE:MO=RXORX-103-5;

RXBLE:MO=RXORX-103-8;RXBLE:MO=RXORX-103-9;

RXBLE:MO=RXOTS-103-0-0&&-7;RXBLE:MO=RXOTS-103-1-0&&-7;

RXBLE:MO=RXOTS-103-4-0&&-7;RXBLE:MO=RXOTS-103-5-0&&-7;

RXBLE:MO=RXOTS-103-8-0&&-7;RXBLE:MO=RXOTS-103-9-0&&-7;

!-------------------------------------------------------------------------!! ***** ACTIVATE CELL(s) ***** !!-------------------------------------------------------------------------!

RLSTC:CELL=COL103A,CHGR=0, STATE=ACTIVE;RLSTC:CELL=COL103B,CHGR=0, STATE=ACTIVE;RLSTC:CELL=COL103C,CHGR=0, STATE=ACTIVE;

!-------------------------------------------------------------------------!! ***** SEIZURE SUPERVISION OF LOGICAL CHANNELS ***** !!-------------------------------------------------------------------------!

RLVLI:CELL=COL103A,CHTYPE=TCH;RLVLI:CELL=COL103A,CHTYPE=SDCCH;RLVLI:CELL=COL103B,CHTYPE=TCH;RLVLI:CELL=COL103B,CHTYPE=SDCCH;RLVLI:CELL=COL103C,CHTYPE=TCH;RLVLI:CELL=COL103C,CHTYPE=SDCCH;

!-------------------------------------------------------------------------!! ***** SUPERVISION OF LOGICAL CHANNEL AVAILABILITY ***** !

!-------------------------------------------------------------------------!

RLSLI:CELL=COL103A;RLSLI:CELL=COL103B;RLSLI:CELL=COL103C;

!-------------------------------------------------------------------------!! ***** SYSTEM INFORMATION BCCH MESSAGE ***** !!-------------------------------------------------------------------------!

RLSMC:CELL=COL103A,MSGDIST=ON, SIMSG=1&7&8;RLSMC:CELL=COL103B,MSGDIST=ON, SIMSG=1&7&8;RLSMC:CELL=COL103C,MSGDIST=ON, SIMSG=1&7&8;

!$$$$!

RLGSI:Cell=cell; to activate GPRS IN cell