BRITISH STANDARD CABLES
TWIN AND EARTHARCTIC GRADE
6181Y6381Y
309_Y HRCU/XLPE/PVC/AWA/PVC
BS 5467BS 5467 CONTROL
BS 6724BS 6724 CONTROL
BRITISH STANDARD CABLES
123
Max. OperationTemperature
CONSTRUCTION
123
Copper conductor (class 5)PVC insulation (cold resistant)PVC outer sheath (cold resistant)
SPECIFICATIONSCode : ARCTIC GRADEStandards : BS 7919Rated voltage : Uo/U=300/500 V
Application :Used in low mechanical stress applications in dry or humidplaces, especially at home appliances such as connectioncables. Insulation and outer sheath compound are resistant tolow temperature which makes cable usable at sub-zerotemperature conditions.
Temperature Range
C60
Short CircuitTemperature
150C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
-40 / +50 Co
Flexible
rD<12=5DD>12=6D
Cold Resistance
ARCTIC GRADE
86
12
3
123
Copper conductor (class 1-2)PVC insulationPVC outer sheath
SPECIFITATIONSCode : TWIN AND EARTH / 624_YStandards : BS 6004Rated voltage : Uo/U=300/500 V
Application :Used in low mechanical stress applications in dry or humidplaces, especially at home appliances such as connectioncables. Not useful for outdoor applications.
Temperature Range
-20 / +60 Co
Max. Operation Temperature
C
60
Short Circuit Temperature
150C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
rr=6 x D
TWIN AND EARTH
Temperature Range
C60
Short CircuitTemperature
150C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
-40 / +50 Co
Flexible
rD<12=5DD>12=6D
Cold ResistanceTemperature Range
C60
Short CircuitTemperature
150C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
-40 / +50 Co
Flexible
rD<12=5DD>12=6D
Cold Resistance
CONSTRUCTION
BRITISH STANDARD CABLES
87
CONSTRUCTION
123
Copper conductor (class 5)PVC insulationPVC outer sheath
SPECIFICATIONSCode : 6381YStandards : BS 6004Rated voltage : Uo/U=300/500 V
Application :Used in low mechanical stress application in dry or humid placessuch as manufacturing facilities and office etc. over and underplaster.
Temperature Range
-20 / +60 Co
Max. OperationTemperature
C
70Short CircuitTemperature
160C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
rr=6 x D
6381Y
123
CONSTRUCTION
123
Copper conductor (class 1-2)PVC insulationPVC outer sheath
SPECIFICATIONSCode : 6181YStandards : BS 6004Rated voltage : Uo/U=300/500 V
Application :Used in low mechanical stress application in dry or humid placessuch as manufacturing facilities and office etc. over and underplaster.
Temperature Range
-20 / +60 Co
Max. OperationTemperature
C
70Short CircuitTemperature
160C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
rr=6 x D
6181Y
123
Flexible
BRITISH STANDARD CABLES
88
CONSTRUCTION
12345
Copper conductor (class 2)XLPE insulationPVC separation sheathAluminium wirePVC outer sheath
SPECIFICATIONSCode : Cu/XLPE/PVC/AWA/PVCStandards : BS 5467Rated voltage : Uo/U= 0.6/1 kV
Application :Mainly used in populated areas, power and switching stationsand underground. Through its armoured structure, cables iscompletely protected from mechanical damage.
Temperature Range Max. OperatingTemperature
C
90Short CircuitTemperature
250C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius
rr=15 x D
RoHS
-20 / +60 C
Mechanical Resistance
CU/XLPE/PVC/AWA/PVC
BASEC Certificate
12345
CONSTRUCTION
123
Copper conductor (class 5)PVC insulation (heat resistant)PVC outer sheath (heat resistant)
SPECIFICATIONSCode : 309_Y HRStandards : BS 6500Rated voltage : Uo/U=300/500 V
Application :Used in low mechanical stress applications in dry or humidplaces, especially at home appliances such as connectioncables. Outer sheath compound is resistant to high temperaturewhich makes cable usable at very hot conditions.
309_Y HR
Temperature Range
-20 / +80 Co
Max. OperationTemperature
C90
Short CircuitTemperature
150C
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHSFlexible
rD<12=5DD>12=6D
123
CONSTRUCTION
123456
Copper conductor (class 2)XLPE insulationPolyester tapePVC BeddingGalvanized round steel wirePVC outer sheath
SPECIFICATIONS
Code : CU/XLPE/SWA/PVCStandards : BS 5467Rated Voltage : Uo/U= 0.6/1 kV
Application :Mainly used in populated areas, power and switching stationsand underground. Through its steel wire armoured structure,cable is completely protected from mechanical damage risk.
BS5467
Temperature Range Max. OperatingTemperature
Short CircuitTemperature
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
C
90-20 / +60 C
r250C
Mechanical Resistance
r=15 x D
PHYSICAL AND ELECTRICAL PROPERTIES
BRITISH STANDARD CABLES
BASEC Certificate
mm2 mm kg/km m ½ / km (max.) A Acm12141516192126281315161820232830323841465055616314161720232730
300390470580860
113017002100
335440550770
1000135020402560290041005250678081009800
1225014900
400510640890
120017802430
1000100010001000100010001000100010001000100010001000100010001000100010001000
500500500500500
1000100010001000100010001000
3140526486
112145174
3140526486
112145174206254305348392444517585
3140526486
112145
243242537498
133162
243242537498
133162197250308359412475564649
243242537498
133
12.17.414.613.081.831.15
0.7270.524
12.17.414.613.081.831.15
0.7270.5240.3870.2680.1930.1530.124
0.09910.07540.0601
12.17.414.613.081.831.15
0.727
3x1.53x2.53x43x63x103x163x253x354x1.54x2.54x44x64x104x164x254x354x504x704x954x1204x1504x1854x2404x3005x1.55x2.55x45x65x105x165x25
rmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmsmsmsmsmsmsmsmsmrmrmrmrmrmrmrm
809090
100110120140150
8090
100110120130150150160200200180200210220220
90100100120130140150
Earth Air
Current carrying capacity in (30°C)Nominalcross-section
Overalldiameterapprox.
Net weightapprox.
Standartdelivery length
Conductor DCresistance
at 20°C
Delivery drumtype
12346 5
89
CONSTRUCTION
12345
Copper conductor (class 2)XLPE insulationPVC BeddingGalvanized round steel wirePVC outer sheath
SPECIFICATIONS
Code : Cu/XLPE/SWA/PVCStandards : BS 5467Rated Voltage : Uo/U=0.6/1 kV
Application :Used as control cables in energy panels of power centres andindustrial buildings etc. internally, externally or underground inwhere hard working conditions are necessary.
BS 5467
mm2 mm kg/km ½ / km (max.) A Am
12345
Temperature Range Max. OperatingTemperature
Short CircuitTemperature
Flame RetardantIEC 60332 -1-2
Min. Bending Radius RoHS
C
90-20 / +60 C
r250C
Mechanical Resistance
r=15 x D
PHYSICAL AND ELECTRICAL PROPERTIES
BRITISH STANDARD CABLES
BASEC Certificate
Earth Air
Current carrying capacity in (30°C)Nominalcross-section
Overall diameterapprox.
Net weightapprox.
Conductor DCresistance
at 20°C
Delivery drum typefor 1000 m. cable
151819202224262830172022242627293135
450615775820975
1200138015501875590810
1020123014601600185020802750
90110110120120130140150150100120120130140140150160180
12.112.112.112.112.112.112.112.112.17.417.417.417.417.417.417.417.417.41
242424242424242424323232323232323232
313131313131313131404040404040404040
7x1.510x1.512x1.514x1.519x1.521x1.524x1.530x1.540x1.57x2.5
10x2.512x2.514x2.519x2.521x2.524x2.530x2.540x2.5
rmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrm
90
CONSTRUCTION
12345
Copper conductor (class 2)XLPE insulationLSZH beddingGalvanized round steel wireLSZH outer sheath
SPECIFICATIONS
PHYSICAL AND ELECTRICAL PROPERTIES
TemperatureRange
Max. OperatingTemperature
Short CircuitTemperature
Flame RetardantIEC 60332 -1-2
Min. BendingRadius
RoHS
-20 / +70 C
C
90 r250C
Flame RetardantIEC 60332 -3-24 Cat.C
CIBr FI
Halogen FreeIEC 60754-1/2
Low Smoke EmissionIEC 61034-1/2
r=15 x D
1235 4
mm2 mm kg/km m ½ / km (max.) A A
Earth Air
Current carrying capacity in (30°C)Nominalcross-section
Overall diameterapprox.
Net weightapprox. Delivery length
Conductor DCresistance
at 20°C
cm
Delivery drumtype
121415161921262830131516182023283032374146505561651415171922263033
3x1.53x2.53x43x63x103x163x253x353x504x1.54x2.54x44x64x104x164x254x354x504x704x954x1204x1504x1854x2404x3005x1.55x2.55x45x65x105x165x255x35
rmrmrmrmrmrmrmrmsmrmrmrmrmrmrmrmrmsmsmsmsmsmsmsmsmrmrmrmrmrmrmrmrm
3140526486
1121451742063140526486
1121451742062543053483924445175853140526486
112145174
243242537498
133162197243242537498
133162197250308359412475564649243242537498
133162
809090
1001101201401501508090
1001101201301501501601802001802002102202409090
100110120140150160
300380470570860
1120170021002400330440535760
100013302025255031004340558072008750
105501307015900
390494625875
1200175024003050
10001000100010001000100010001000100010001000100010001000100010001000100010001000500500500500500
10001000100010001000100010001000
12,17,414,613,081,831,15
0,7270,5240,38712,17,414,613,081,831,15
0,7270,5240,3870,2680,1930,1530,124
0,09910,07540,0601
12,17,414,613,081,831,15
0,7270,524
Code : Cu/XLPE/LSZH/SWA/LSZHStandards : BS 6724Rated Voltage : Uo/U=0.6/1 kV
Application :These cables can withstand mechanical stress. Used in placeswhich are subject to fire danger such as hotels, hospitals, shoppingcenters, power plants, information technology centers and inplaces where human groups are carried by railway systems andalso where valuable equipments are kept. These cables do notconduct flame during fire, do not create high smoke density, donot create corrosive ambients and therefore provides increasedprotection. Can be used internally, externally or in underground.
BRITISH STANDARD CABLES
91
BS 6724
CONSTRUCTION
12345
Copper conductor (class 2)XLPE insulationLSZH BeddingGalvanized round steel wireLSZH outer sheath
SPECIFICATIONS
Code : Cu/XLPE/LSZH/SWA/LSZHStandards : BS 6724Rated Voltage : Uo/U=0.6/1 kV
Application :Used as control cables in energy panels of power centres athuman densed places or buildings internally, externally orunderground. Due to its characteristics; these cables do notconduct flame. Neither high smoke density nor corrosive ambients are are released from these cables during fire.
BS 6724
mm2 mm kg/km ½ / km (max.) A Am
12345
TemperatureRange
Max. OperatingTemperature
Short CircuitTemperature
Flame RetardantIEC 60332 -1-2
Min. BendingRadius
RoHS
C
90-20 / +60 C
r250C
MechanicalResistance
r=15 x D
PHYSICAL AND ELECTRICAL PROPERTIES
BASEC Certificate
Earth Air
Current carrying capacity in (30°C)Nominalcross-section
Overall diameterapprox.
Net weightapprox.
Conductor DCresistance
at 20°C
Delivery drum typefor 1000 m. cable
151819202224262830172022242627293135
450615775820975
1200138015501875590810
1020123014601600185020802750
90110110120120130140150150100120120130140140150160180
12.112.112.112.112.112.112.112.112.17.417.417.417.417.417.417.417.417.41
242424242424242424323232323232323232
313131313131313131404040404040404040
7x1.510x1.512x1.514x1.519x1.521x1.524x1.530x1.540x1.57x2.5
10x2.512x2.514x2.519x2.521x2.524x2.530x2.540x2.5
rmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrmrm
92
Flame RetardantIEC 60332 -3-24 Cat.C
BRITISH STANDARD CABLES