11
VG VG 1 W.O. Miller i T i i T i Bridge Thermal Model Bridge Thermal Model Salient Features Salient Features High conductivity (700W/mK, 0.5mm thick) CC bridge material High conductivity (700W/mK, 0.5mm thick) CC bridge material support for 0.28mm thick hybrid(1W/mK) support for 0.28mm thick hybrid(1W/mK) 40 chips @ 0.25W/chip 40 chips @ 0.25W/chip Detector 0.28mm thick, 148W/mK Detector 0.28mm thick, 148W/mK Allcomp carbon foam for bridge support (isotropic 45W/mK) Allcomp carbon foam for bridge support (isotropic 45W/mK) Carbon Foam for tube support (45/45/45 W/mK) Carbon Foam for tube support (45/45/45 W/mK) Reduced density over POCO foam (0.2g/cc versus 0.5 g/cc) Reduced density over POCO foam (0.2g/cc versus 0.5 g/cc) Sandwich foam Sandwich foam Allcomp foam option, ~0.1g/cc @ 3W/mK Allcomp foam option, ~0.1g/cc @ 3W/mK Comparison with Hybrid on 10cm Detector Comparison with Hybrid on 10cm Detector Thermal solution with both with inner tube wall at -28 Thermal solution with both with inner tube wall at -28 ºC ºC Simulates -30 Simulates -30 ºC with 8000W/m ºC with 8000W/m 2 K No change made to material properties in 10cm detector No change made to material properties in 10cm detector with integrated hybrid with integrated hybrid

Bridge Thermal Model

Embed Size (px)

DESCRIPTION

Bridge Thermal Model. Salient Features High conductivity (700W/mK, 0.5mm thick) CC bridge material support for 0.28mm thick hybrid(1W/mK) 40 chips @ 0.25W/chip Detector 0.28mm thick, 148W/mK Allcomp carbon foam for bridge support (isotropic 45W/mK) - PowerPoint PPT Presentation

Citation preview

Page 1: Bridge Thermal Model

VG VG 11W.O. Miller

i T ii T i

Bridge Thermal ModelBridge Thermal Model

• Salient FeaturesSalient Features– High conductivity (700W/mK, 0.5mm thick) CC bridge material support High conductivity (700W/mK, 0.5mm thick) CC bridge material support

for 0.28mm thick hybrid(1W/mK)for 0.28mm thick hybrid(1W/mK)– 40 chips @ 0.25W/chip40 chips @ 0.25W/chip– Detector 0.28mm thick, 148W/mKDetector 0.28mm thick, 148W/mK– Allcomp carbon foam for bridge support (isotropic 45W/mK)Allcomp carbon foam for bridge support (isotropic 45W/mK)– Carbon Foam for tube support (45/45/45 W/mK)Carbon Foam for tube support (45/45/45 W/mK)

• Reduced density over POCO foam (0.2g/cc versus 0.5 g/cc)Reduced density over POCO foam (0.2g/cc versus 0.5 g/cc)– Sandwich foamSandwich foam

• Allcomp foam option, ~0.1g/cc @ 3W/mKAllcomp foam option, ~0.1g/cc @ 3W/mK

• Comparison with Hybrid on 10cm DetectorComparison with Hybrid on 10cm Detector– Thermal solution with both with inner tube wall at -28Thermal solution with both with inner tube wall at -28ºCºC

• Simulates -30Simulates -30ºC with 8000W/mºC with 8000W/m22KK

• No change made to material properties in 10cm detector No change made to material properties in 10cm detector with integrated hybrid with integrated hybrid

Page 2: Bridge Thermal Model

VG VG 22W.O. Miller

i T ii T i

10cm Detector-No Bridge10cm Detector-No Bridge

Old model parameters

Page 3: Bridge Thermal Model

VG VG 33W.O. Miller

i T ii T i

10cm Detector-No Bridge10cm Detector-No Bridge

• Material PropertiesMaterial Properties– See previous slide (#2)See previous slide (#2)

• 40 chips per detector, 80 40 chips per detector, 80 totaltotal– 0.25W/chip Q (Si)=0W0.25W/chip Q (Si)=0W– Tube inner surface -28Tube inner surface -28ºC, no ºC, no

convection coefficientconvection coefficient

• Interest in Interest in ΔΔT from chip T from chip and detector surface to and detector surface to tube surfacetube surface

• Peak chip temperaturePeak chip temperature– Middle hybrid region: -20.5ºCMiddle hybrid region: -20.5ºC

• Peak DetectorPeak Detector– Middle hybrid region: -21.5ºCMiddle hybrid region: -21.5ºC

– ΔΔT in region of max T in region of max gradient: 6.5ºCgradient: 6.5ºC

Page 4: Bridge Thermal Model

VG VG 44W.O. Miller

i T ii T i

10 CM Wide Stave-No Bridge10 CM Wide Stave-No Bridge

• SolutionSolution– Replaced honeycomb Replaced honeycomb

core with Allcomp carbon core with Allcomp carbon foam (<0.2g/cmfoam (<0.2g/cm33: : 45W/mK)45W/mK)

– Also, replaced POCO Also, replaced POCO foam tube support with foam tube support with same foamsame foam

• Peak Chip Temp: -Peak Chip Temp: -22.722.7ºCºC

• Peak Detector: -24ºCPeak Detector: -24ºC– ΔΔT (referenced to tube T (referenced to tube

wall)wall)

• 4ºC4ºC

Page 5: Bridge Thermal Model

VG VG 55W.O. Miller

i T ii T i

10 CM Wide Stave-No Bridge10 CM Wide Stave-No Bridge

• Solution: Simulate “outer” Solution: Simulate “outer” long strip detectorlong strip detector– One upper and power hybrid for One upper and power hybrid for

10cm detector10cm detector– 20 chips @ 0.25W/chip20 chips @ 0.25W/chip– Coolant tube inner surface: -28Coolant tube inner surface: -28ºCºC– Materials, see slide (#2)Materials, see slide (#2)

• DetectorDetector– Peak temp beneath hybrid: -Peak temp beneath hybrid: -

24.824.8ºCºC– ΔΔT in region of max gradient: T in region of max gradient:

3.2ºC3.2ºC

• Chip Peak Temp: -24.1ºCChip Peak Temp: -24.1ºC

Page 6: Bridge Thermal Model

VG VG 66W.O. Miller

i T ii T i

Thermal Bridge Model (1/2 of 10cm)Thermal Bridge Model (1/2 of 10cm)

Wire bonds, simulated as thin solid, reduced K to 97W/mK

Chips 0.38mm thick (148W/mK)

Al Cooling tube 0.21mm ID

Separation between facings 4.95mm

10cm

Foam bridge support

1mm air gap for bridge

Page 7: Bridge Thermal Model

VG VG 77W.O. Miller

i T ii T i

Bridge Thermal ModelBridge Thermal Model

Enclosed bridge model in an air box. Air participates only through pure conduction. Air fills all cavities not occupied by a solid

Air box

Page 8: Bridge Thermal Model

VG VG 88W.O. Miller

i T ii T i

Model ParametersModel Parameters

Cable and adjacent adhesive layers modeled as single layer 0.227mm and K=0.31W/mK

Page 9: Bridge Thermal Model

VG VG 99W.O. Miller

i T ii T i

Solution with -30Solution with -30ºC ºC Tube 8000 W/mTube 8000 W/m22K K 0.5W/chip Q (Si)=00.5W/chip Q (Si)=0

Slight asymmetry caused by variance in interior coolant wall temperature

Detector max=-21.4ºC

Chip peak=-16.5ºC

Page 10: Bridge Thermal Model

VG VG 1010W.O. Miller

i T ii T i

Solution with -30Solution with -30ºC ºC Tube 8000 W/mTube 8000 W/m22K K 0.25W/chip Q (Si)=00.25W/chip Q (Si)=0

Slight asymmetry caused by variance in interior coolant wall temperature

Detector max=-25.8ºC

Chip peak=-23.3ºC

Page 11: Bridge Thermal Model

VG VG 1111W.O. Miller

i T ii T i

Solution with -30Solution with -30ºC ºC Tube 8000 W/mTube 8000 W/m22K K 0.25W/chip Q (Si)=00.25W/chip Q (Si)=0

Bridge foam and tube foam 45W/mk, density ~0.2 g/cm3(no POCO foam) Peak detector temp -24.2ºC

Sandwich foam core 3W/mK, density ~0.06 g/cm3

Peak chip=-21.8ºC

Wire bonds 97W/mK