22
Brain Electrical Source Analysis This is most likely location of dipole Project “Forward Solution” Compare to actual data

Brain Electrical Source Analysis

  • Upload
    yeva

  • View
    48

  • Download
    0

Embed Size (px)

DESCRIPTION

Brain Electrical Source Analysis. Project “Forward Solution”. This is most likely location of dipole. Compare to actual data. Brain Electrical Source Analysis. EEG data can now be coregistered with high-resolution MRI image. Anatomical MRI. Brain Electrical Source Analysis. - PowerPoint PPT Presentation

Citation preview

Page 1: Brain Electrical Source Analysis

Brain Electrical Source Analysis

This is most likely location of dipole

Project “Forward Solution”

Compare to actual data

Page 2: Brain Electrical Source Analysis

Brain Electrical Source Analysis

• EEG data can now be coregistered with high-resolution MRI image

Anatomical MRI

Page 3: Brain Electrical Source Analysis

Brain Electrical Source Analysis

• EEG data can now be coregistered with high-resolution MRI image

Anatomical MRI

3D volume is rendered and electrode locations are superimposed

Page 4: Brain Electrical Source Analysis

Brain Electrical Source Analysis

• EEG data can now be coregistered with high-resolution MRI image

Page 5: Brain Electrical Source Analysis

Magnetoencephalography

• For any electric current, there is an associated magnetic field

Magnetic Field

Electric Current

Page 6: Brain Electrical Source Analysis

Magnetoencephalography

• For any electric current, there is an associated magnetic field

• magnetic sensors called “SQuID”s can measure very small fields associated with current flowing through extracellular space

Magnetic Field

Electric Current

SQuIDAmplifier

Page 7: Brain Electrical Source Analysis

Magnetoencephalography

• MEG systems use many sensors to accomplish source analysis

• MEG and EEG are complementary because they are sensitive to orthogonal current flows

• MEG is very expensive

Page 8: Brain Electrical Source Analysis

MEG/EEG

• Any complex waveform can be decomposed into component frequencies– E.g.

• White light decomposes into the visible spectrum• Musical chords decompose into individual notes

Page 9: Brain Electrical Source Analysis

MEG/EEG

• MEG/EEG is characterized by various patterns of oscillations

• These oscillations superpose in the raw data

4 Hz

8 Hz

15 Hz

21 Hz

4 Hz + 8 Hz + 15 Hz + 21 Hz =

Page 10: Brain Electrical Source Analysis

How can we visualize these oscillations?• The amount of energy at any frequency is expressed as

% power change relative to pre-stimulus baseline

• Power can change over time

Freq

uenc

y

Time0

(onset)+200 +400

4 Hz

8 Hz

16 Hz

24 Hz

48 Hz

% changeFromPre-stimulus

+600

Page 11: Brain Electrical Source Analysis

Where in the brain are these oscillations coming from?

• We can select and collapse any time/frequency window and plot relative power across all sensors

Win Lose

Page 12: Brain Electrical Source Analysis

Where in the brain are these oscillations coming from?

• Can we do better than 2D plots on a flattened head?

• As in ERP analysis we (often) want to know what cortical structures might have generated the signal of interest

• One approach to finding those signal sources is Beamformer

Page 13: Brain Electrical Source Analysis

Beamforming

• Beamforming is a signal processing technique used in a variety of applications:– Sonar– Radar– Radio telescopes– Cellular transmision

Page 14: Brain Electrical Source Analysis

Beamforming in EEG/MEG

• It then adjusts the signal recorded at each sensor to tune the sensor array to each voxel in turn

Q = % signal change over baseline

Page 15: Brain Electrical Source Analysis

Beamformer

• To apply Beamformer to EEG or MEG data we first select the band and time window of interest – in this case theta between about 175 and 375 ms

Page 16: Brain Electrical Source Analysis

Beamformer

• Applying the Beamformer approach yields EEG or MEG data with fMRI-like imaging

L

R

Page 17: Brain Electrical Source Analysis

Your Research Proposal Project

• A research proposal attempts to persuade the reader that:– The underlying question is highly important– The proposed methodology and experimental design is the

best approach– That you have the knowledge and know-how to do the

proposed research

L

R

Page 18: Brain Electrical Source Analysis

Your Research Proposal Project

• A research proposal is therefore similar to many other situations in which you will try to persuade someone of something– The skill is portable

L

Page 19: Brain Electrical Source Analysis

Your Research Proposal Project

• As in other situations, your reader should be assumed to be unconvinced and thus unwilling to spend much time and energy entertaining your argument!

• You must make your argument easy and fast

• The key to that is organization

L

Page 20: Brain Electrical Source Analysis

Research Proposals Should be “Theory Driven”

• Most proposals are organized around a specific theory

• What is the difference between a theory and a question?

L

Page 21: Brain Electrical Source Analysis

The Parts of a Research Proposal

• Background• Statement of the theory• Prediction(s) that follow from the theory• Experimental Method and Design• Timeline• Budget• References

L

Page 22: Brain Electrical Source Analysis

The Parts of a Research Proposal

• Background• Statement of the theory• Prediction(s) that follow from the theory• Experimental Method and Design• Timeline• Budget• References

L

These aren’t necessary for your project