6
Polysorb Braided, Synthetic Absorbable Suture STRENGTH AND SECURITY WHEN IT’S NEEDED MOST

Braided, Synthetic Absorbable Suture - Amtech · 2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE Polysorb ... upholding and advancing the standards of effectiveness for sutures throughout

Embed Size (px)

Citation preview

Page 1: Braided, Synthetic Absorbable Suture - Amtech · 2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE Polysorb ... upholding and advancing the standards of effectiveness for sutures throughout

Polysorb™ Braided, Synthetic Absorbable Suture

STRENGTH AND SECURITY WHEN IT’S NEEDED MOST

Page 2: Braided, Synthetic Absorbable Suture - Amtech · 2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE Polysorb ... upholding and advancing the standards of effectiveness for sutures throughout

Polysorb™ suture provides statistically equivalent levels of bacterial colonisation as compared to both Vicryl™* Plus suture and Vicryl™* suture.4

Vicryl™* Suture Polysorb™ Suture

Biosyn™ SutureVicryl™* Plus Suture

100000

10000

1000

100

10

1

DAY 0 DAY 1 DAY 2 DAY 6

**

*all braided suture statistically equivalent at all time points4

CFU

S/M

L

BACTERIAL COLONISATION (STAPHYLOCOCCUS AUREUS)

*

Page 3: Braided, Synthetic Absorbable Suture - Amtech · 2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE Polysorb ... upholding and advancing the standards of effectiveness for sutures throughout

We’re all part of the same community. A community entrusted with

enhancing and saving the lives of patients. At Covidien, we actively help

you and all of our partners in the healthcare community. Every day.

Together, we can

provide your patients

with optimal care and

quality of life. Today,

Tomorrow and Beyond.

Page 4: Braided, Synthetic Absorbable Suture - Amtech · 2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE Polysorb ... upholding and advancing the standards of effectiveness for sutures throughout

Polysorb™ Suture. Strength and Security, When It’s Needed Most.

TEN

SILE

STR

ENG

TH (K

g of

For

ce)

6.0

5.0

4.0

3.0

2.0

1.0

0

WEEK 0 WEEK 1 WEEK 2 WEEK 3

2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE

Polysorb™ suture is 37% stronger out-of-package1

Polysorb™ suture provides 21% greater strength during the critical wound-healing period

Polysorb™ Suture

Vicryl™* Suture

You Want the Best for Your Patients.That’s where Covidien comes in. You can rely on our Polysorb™ sutures to deliver the treatment your patients need to heal successfully.

Polysorb™ suture is 21% stronger than Vicryl™* suture during the critical wound healing period with a similar absorption profile.1

Polysorb™ suture’s sheath and core design has a greater number of finer fibers giving it a superior tensile strength over Vicryl™* suture.

Our robust manufacturing and quality testing processes ensure that the products we put in your hands are reliable and effective.

Page 5: Braided, Synthetic Absorbable Suture - Amtech · 2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE Polysorb ... upholding and advancing the standards of effectiveness for sutures throughout

• Significantly stronger knot security than Vicryl™* suture.2

• Significantly less drag force than Vicryl™* suture.2

PERFORMANCE

• Significantly lower mean cumulative incidence of suture spitting compared to Vicryl™* suture 31% vs. 19%.3

PEACE OF MIND

• Stronger out of the package than Vicryl™* suture and after it is knotted which provides greater strength during surgery.1

• 21% stronger than Vicryl™* suture during the critical wound healing period, when strength is most important.1

STRENGTH

Dedication To Product ImprovementYour patients’ well being can never be compromised, which is why we have been upholding and advancing the standards of effectiveness for sutures throughout our history.

CUM

ULAT

IVE

INCI

DEN

CE

OF

SUTU

RE S

PITT

ING

(%)

30

25

20

15

10

5

0

WEEK 1 WEEK 2 WEEK 3 WEEK 4 WEEK 5

Polysorb™ SutureVicryl™* Suture

Why Use Polysorb™ Suture?KNOT BREAKING STRENGTH (N)

Four throw knot (1x1=1=1)

Size 0 Polysorb™ SutureSize 0 Vicryl™* Suture

0 1 2 3 4

6.04

4.81

5 6 7

TISSUE DRAG FORCE (g)

Size 0 Polysorb™ SutureSize 0 Vicryl™* Suture

0 30 60 90 120

24.54

142.88

150

Page 6: Braided, Synthetic Absorbable Suture - Amtech · 2/0 BRAIDED SYNTHETIC ABSORBABLE SUTURE Polysorb ... upholding and advancing the standards of effectiveness for sutures throughout

references

1 Covidien Internal R&D, Tensile strength size 2/0, Kg of force.

2 Faulkner, et al, University of Virginia School of Medicine, Biomechanical Performance of a Braided Absorbable Suture, 1996.

3 Drake, et al, University of Virginia Health Sciences Center, Experimental Studies in Swine for Measurement of Suture Extrusion, 2004.

4 Covidien Internal R&D. In Vitro Evaluation of Staphylococcus aureus of commercial Braided Synthetic Absorbable (BSA) suture materials (some containing Triclosan) and Monofilament Synthetic Absorbable (MSA) sutures, 2006.

SPECIFICATIONS

COMPOSITION: Lactomer Glycolide/Lactide Copolymer coated with Caprolactone and Calcium Stearoyl Lactylate

SUTURE SIZE OPTIONS: Available in all sizes USP sizes 2 (5 metric) through 8-0 (0.4 metric)

SUTURE LENGTH OPTIONS: Available in 13cm, 20cm, 30cm, 45cm, 60cm, 75cm, 90cm, 100cm, 120cm, 150cm, 240cm, 250cm, 366cm as well as Reels, Precuts and Standard Length.

NEEDLE OPTIONS: • Conventional Cutting• Reverse Cutting• Premium Reverse Cutting• Spatula• Premium Spatula• Multipurpose • Straight Cutting• Taper Point• Taper Cutting• Blunt Point • Blunt Taper

For more information or to set up a product demonstration, contact your local Covidien wound closure specialist

COVIDIEN, COVIDIEN with logo, Covidien logo and “positive results for life” are U.S. and internationally registered trademarks of Covidien AG. ™ Trademark of a Covidien company. ™* Trademark of its respective owner. © 2013 Covidien. Suture 252-09-13 Polysorb Brochure

Covidien Pty Ltd 166 Epping Road, Lane Cove NSW 2066 Australia (t) 1800 252 467

Covidien New Zealand LtdCentral Park Corporate CentreLevel 3, Building 5666 Great South RoadPenrose, Auckland 1051(t) 0508 489 264

www.covidien.com