8
A fully mechanized rock bolting rig for bolt lengths from 1.5-3.5 m heights up to 9.5 meters BOLTEC M

Boltec M Technical specification - Atlas Copco spacing, controlled grout ratios, ... (16A or 32A socket size) ... Rebar - manual resin / cement cartridge,

Embed Size (px)

Citation preview

A fully mechanized rock bolting rig for bolt lengths from 1.5-3.5 m heightsup to 9.5 meters

BOLTEC M

A FULLY MECHANIZED ROCK BOLTING RIG FOR BOLT LENGTHS FROM 1.5-3.5 METERS. EFFECTIVE IN ROOF HEIGHTS UP TO 9.5 METERS.

MAIN BENEFITS

Productivity The Mechanised Bolting Unit (MBU) utilises a single feed rail concept that means that the unit never moves off the drilled bolt hole - this maximises the hole alignment capabilities when installing the bolt and ensures faster installation times.

Rock Drill The COP 1132 rock drill is optimised for bolt hole drilling, with it’s light weight and high frequency it reduces loads on the boom whilst achieving superior penetration rate. For larger hole diameters required for some friction bolt types or harder rock conditions the optional COP 1435 delivers the hitting power needed to get the job done.

Carrier Commonality The Boltec M-series machines share a common four wheel drive articulated carrier design with their Simba M/E and Boomer M/E stablemates. With an open service architechture philosophy it allows for fast and easy maintenance.

BOLTEC M MAKING MINING SAFE

2

Optional bulk cement silo for cement grouted bolts

Optional mesh handling arm

3

+ SAFETY Mechanised bolting removes the operator from the potential danger

area of unsupported ground. All drilling and bolt installation is controlled from the operator station under a FOPS canopy or optional ROPS/FOPS air

conditioned cabin.

+ BOLT INSTALLATION QUALITYMechanised bolting typically holds a much higher installation quality and

consistency than manual or semi-mechanised installation. Bolt angles, bolt spacing, controlled grout ratios, installation pressures, and bolt

numbers are just some of the data that can be collected or recorded.

+ OPERATOR COMFORTThe operator position affords excellent visibility of the bolting operation

as well as when tramming the vehicle. The operator area is spacious and features a swingable operator seat for driving and bolting. The optional

ROPS/FOPS air conditioned cabin enhances the operator’s comfort especially in extreme temperatures or dusty conditions.

BOLTEC M

SAFE BOLTINGSAFETY AND QUALITY OF BOLT INSTALLATION IS OUR FOCUS. THE BOLTEC M IS DESIGNED WITH STANDARD AND OPTIONAL FEATURES THAT ENSURE THESE GOALS ARE MET.

ATLAS COPCO SERVICE– IT’S NOT JUST ABOUT OUR PROMISES, IT’S ABOUT DELIVERYWe offers several levels of service agreements to meet the requirements of your operation and to se-cure your productivity. Our service agreements help you build a quality operation focused on proactive, planned maintenance to minimize unplanned down-time. We support maintenance with detailed parts information on every piece within our full inventory of components, accessories, and tools.

4

BUT 35HBE

Automatic boom lubrication system, rear part

Central boom lubrication kit

Ni-Cr boom cylinders for corrosive conditions

COP 1132

COP 1435

Rock drill lubrication, air dryer system

Air-water mist flushing, external water, internal air, hydraulic oil cooled by air fan

Air-water mist flushing, external water, internal air, hydraulic oil cooled by water

Air-water mist flushing, internal water, internal air, hydraulic oil cooled by air fan

Rock drill lubrication warning kit

Hole blowing kit

ROCK DRILL A B

TECHNICAL SPECIFICATIONS

Total installed power 63 kW (Auto cement, 83 kW)

Main motors 55 kW (Auto cement, 75 kW)

Voltage 380-1 000 V

Frequency 50Hz

Frequency 60 Hz

Soft start (380–690 V)

Transformer 8 kVA

Electronic overload protection for electric motors

Digital volt/ampere meter in electrical cabinet

Phase sequence and eart fault indicator

Battery charger

Cable reel with limiting switch

Electrical outlet, main supply voltage 16Amp 3-phase (16A or 32A socket size) - not for 1000V

Extra transformer 3-phase 15kVA capacity with 230V and 400V outlet (16A or 32A socket size)

PC4 or PC5 Plug/Socket

Spotlight, 1x70 W, 24 V

Illuminated stairs for platform (LED)

ELECTRICAL SYSTEM A B

BOOM A B

BOLTING UNIT A B

Compressor: Atlas Copco GAR5

Hydraulic water booster pump capacity at 7 bar, 80 l/min

Minimum water inlet pressure 2 bar

Water flow and pressure guard for flushing water

Water hose reel, including water hose

High pressure washing kit

AIR/WATER SYSTEM A B

Deutz TCD 2013 L4 120kW 4 cylinder Tier 3 / Stage IIIA diesel engine

Deutz TCD 4.1 115kW 4 cylinder Tier 4 final / Stage IV diesel engine

Articulated ±40° steering angle

Four wheel drive

Hot climate tramming kit

Electrical system 24 V

Batteries 2 x 125 Ah

Automatic differential lock on front axle, limited slip

Tyres, 12.00 R24

Clearance outside axles rear 13°

Front and rear hydraulic jacks

Fuel tank volume 4 cylinder engine 110 L

Central lubrication system

Tramming lights, rear 4 x 40W LED

Tramming lights, rear 2 x 40W LED + 2 x 70W Halogen

Working lights 2 x 320W LED 24V DC

Illuminated stairs for platform

Central grease point

Fire extinguisher

Fire suppression system ANSUL -manual release

Fire suppression system ANSUL -Automatic release (checkfire)

Fire suppression system ANSUL - Automatic release with CO2 in electrical cabinet

CARRIER A B

Mechanical bolting unit

Magazine capacity 10 bolts

Size of face plates, rectangular, diameter, max 150x150 mm

Size of face plates, round, diameter, max Ø 200 mm

Bolt length from 1.5 m to 3.5 m

Swellex, Mn 12, Mn 16, Mn 24

Split-Set, SS39, SS46

Mechanical anchor bolts, CT, Kiruna, including boltrotator

Rebar - manual resin / cement cartridge, including boltrotator

Rebar - resin cartridge injection system, automatic, including boltrotator

Rebar - Cement injection system, manual mixing

REbar - Cement injection system, automatic mixing with bulk cement silo 1 000 kg

Hose injection system for resin cartridges

Dual bolt lengths*

Dual bolt types

Extension drilling kit

Screen handling arm

*2nd bolt length no less than 70% length of maximum bolt length

Low oil level indicator

Oil temperature meter

Filtration 16 μm

Oil filter indicator

Mineral hydraulic oil

Electric oil filling pump

Biodegradable hydraulic oil

Hydraulic oil thermostat

Hydraulic oil leakage detection and shut-down system

Hydraulic oil fine particulate and water filtration system (not in conjunction with bulk cement system)

HYDRAULIC SYSTEM A B

Rig Control System (RCS)

Bolt quality log (BQL)

Bolt plan navigation

Rig Remote Access (RRA)

Bolt angle indication

Direct Hydraulic Control System (DCS)

CONTROL SYSTEM A B

A = BOLTEC M C = OPTION B = BOLTEC M D = STANDARD

5

Total 21 600 kg

Boom side 15 500 kg

Engine side 6 700 kg

WEIGHT

Width 2 245 mm

Height, Cabin fixed ROPS/FOPS 3 021 mm

Height, Protective roof (min/max) 2 361/3 061 mm

Length tramming MBU34.3 13 937 mm

Ground clearence 254 mm

Turning radius outer/inner 6 600/4 100mm

DIMENSIONS

Voltage Dimension, mm2 Diameter, mm Length

400V 3x185+3G35+2x1x1.5 56 mm 90 m

440V 3x150+3G25+2x1x1.5 52 mm 100 m

460-500V 3x120+3G25+2x1x1.5 46.5 mm 120 m

500-550V 3x95+3G16+2x1x1.5 42 mm 150 m

660-690V 3x70+3G16+2x1x1.5 37 mm 180 m

1000V 3x50+3G10+2x1x1.5 32 mm 200 m

Recommendations are given for surrounding temperature of 40°C

RECOMMENDED CABLE SIZES AND LENGTHS

FOPS/ROPS approved cabin, noise level <80 dB(A)

Low profile cabin ROPS/FOPS 150 mm lower than standard - seated operation only

Low profile cabin ROPS/FOPS 150 mm lower than standard - seated operation only

Cabin height fixed, lowered 140 mm from standard

Cabin height fixed, raised 250 mm from standard

Mediaplayer

12 V outlet for communication radio

Reversing camera with monitor

Air conditioning unit

Heating function for air conditioning (water transferred)

Swingable seat for drilling and tramming

Cabin body made of stainless steel

Joystick-controlled spotlights left and/or right, 70 W

Front window, 24 mm

FOPS-approved grizzly bar for front window

Cabin lift/tilt function (FOPS)

OPTIONAL CABIN A B

On flat ground (Rolling resistance 0.05) >15

On incline 1:8 >5

TRAMMING SPEED

TECHNICAL SPECIFICATIONSA = BOLTEC M C = OPTION B = BOLTEC M D = STANDARD

Mounting height increased 60mm from standard

Mounting height increased 310mm from standard

PROTECTIVE ROOF A B

6

3 262

20°

30°R 6

600

R 1

500

R 4 100

41°

R 7 050

1 2401 240

3 2623 712

9 39

02

230

4 91

3

2 508

3 49

0

EC

www.atlascopco.com

EC

2 105 801

2 661 4 940

4 838

1 430

2 000

13 937

Ø1 238

2 45

057

1

1 19

7

1 940 792

19°10°13°

139

TECHNICAL SPECIFICATIONS

Dimension illustration (Optional equipment mounted).

Coverage area (2.4 m bolts).

Turning radius.

7

COMMITTED TO SUSTAINABLE PRODUCTIVITY

We stand by our responsibilities towards our customers, towards the environment and the people around us. We make performance stand the test of time.This is what we call – Sustainable Productivity.

www.atlascopco.com

98

51 22

02 01i 2

016 Öre

bro, S

we

den

. Le

gal N

otice © C

opyrig

ht 2014

, Atlas C

op

co Ro

ck Drills A

B, Ö

reb

ro, Sw

ed

en. A

ll pro

du

ct nam

es in this pu

blicatio

n are tradem

arks of Atlas C

op

co. Any un

auth

orize

d use or co

pying

of the contents o

r any part there

of is pro

hibite

d. Illustratio

ns and p

hoto

s may sh

ow e

quip

ment w

ith optio

nal extras. N

o warranty is m

ade re

gard

ing sp

ecifi

cations o

r otherwise. S

pe

cificatio

ns and e

quip

ment are su

bje

ct to ch

ang

e with

ou

t notice. C

onsult yo

ur Atlas C

op

co Custo

mer C

enter for sp

ecifi

c inform

ation

.