Dakota Nickerson, Kyle Pflueger , Adam Leschber , Andrew Dahlke M.E. Undergrad. Boiling Water Test Loop University of Idaho . What We Want to Accomplish Today. Provide Insight s found for Initial BWTL Provide Insights found for Proposed BWTL Verify Deliverable for this Project - PowerPoint PPT Presentation

Citation preview

Page 1: Boiling Water Test Loop University  of  Idaho

1

Boiling Water Test LoopUniversity of Idaho

Dakota Nickerson, Kyle Pflueger, Adam Leschber, Andrew Dahlke

M.E. Undergrad

Page 2: Boiling Water Test Loop University  of  Idaho

2

What We Want to Accomplish Today

Provide Insights found for Initial BWTL

Provide Insights found for Proposed BWTL

Verify Deliverable for this Project

Verify Component Selection

Page 3: Boiling Water Test Loop University  of  Idaho

3

BWTL

BWTL- Boiling Water Test Loop

A closed steam loop system that simulates the conditions seen in a Boiling Water Reactor for the purpose of testing nuclear fuel rods in the Advanced Test Reactor (ATR).

Page 4: Boiling Water Test Loop University  of  Idaho

4

BWTL Design Recieved

Condenser or quench tank

Dem

iner

alize

r

Booster Pump

CondensatePump

Circulating Water

Pressure Control Valve

Flow Elements

IsolationValve

Line heater

Heater Element

TE

TE

TE

TE

PI

Temp – 530FPress – 1050 psig

Temp – 100FPress – 2 psig

Temp – 110FPress – 160 psig

PI

Line heaterFeedwater pump

Temp – 400FPress – 1050 psig

Temp – 120FPress – 600 psig

Temp – 545FPress – 1020 psig

Page 5: Boiling Water Test Loop University  of  Idaho

5

Problem Identification

The purpose of this project is to design and build a scaled boiling water test loop

that can be used to verify the boiling regime while controlling inlet and outlet

steam qualities.

Page 6: Boiling Water Test Loop University  of  Idaho

6

Proposed BWTL Design

Line heater

Heater E

lement

Temp – 295 ± 5 FPress – 60 psig

Pressure Relief Valve

Heat Exchanger

PETE

Pump

Temp – 295 ± 5 FPress – 60 psig

PETE

TE

Temp –290 ± 5 FPress – 60 psig

Temp 290 ± 5 FPress – 60 psig

TE

ASME Expansion Tank

1

2

3

456

Page 7: Boiling Water Test Loop University  of  Idaho

7

Value Gained From This Project

1st Pass Prototype that will provide insight into critical design aspects associated with a Boiling Water Test Loop.

Page 8: Boiling Water Test Loop University  of  Idaho

8

1: Cartridge Heater

A Chromalox cartridge heater has been chosen to simulate the 18” nuclear fuel rod.

Dimensions are: 18” length, .500” diameter. The manufacturer has told us we can expect 5.6 kW/ft.

Page 9: Boiling Water Test Loop University  of  Idaho

9

2: Test Section

Option 1: Transparent High Temp Plastic Tube

Poly-Sulfone Rated to 300 F ID of 0.75 in, and OD of 1.00 in. Cost is approximately $100.

Page 10: Boiling Water Test Loop University  of  Idaho

10

2: Test Section

Option 2: Sight Glass Tube

Glass Pressure vessel.

Can be threaded or flanged directly to pipe.

Rated to 500F and 500 psi

Cost: $600

Recommended Design

Page 11: Boiling Water Test Loop University  of  Idaho

11

3: Heater

Circular Flow Heater Will Provide 15 kW of energy into system. Accompanied with Control panel that will provide

inlet and outlet temperature.

Page 12: Boiling Water Test Loop University  of  Idaho

12

4: Pump

Recommended Pump:Manufacturer Model Nominal Capacity at

Maximum SpeedMaximum DifferentialPressure

MaximumTemperature

Cost

GPM PSI ˚F $Viking Pump Heavy duty series-

FH C323 200 800 300-350

Page 13: Boiling Water Test Loop University  of  Idaho

13

5: Heat Exchanger

Cross flow, shell and tube heat exchanger

Capacity in excess of 20 kW

Page 14: Boiling Water Test Loop University  of  Idaho

14

6: Expansion Tank

ASME pressure vessel

Will allow room for water to turn to vapor

Page 15: Boiling Water Test Loop University  of  Idaho

15

Analysis

Linear Heat Rate From The Chromalox Heater:

5.65 kW/ft Required exit quality:

14.6% Assuming inlet quality:

7.5% Expected Scaled Loop Flow Rate:

0.89 gallons per minute

Page 16: Boiling Water Test Loop University  of  Idaho

16

Critical Heat Flux

Critical Heat Flux is 1944 kW/m2

Our heat flux is 464 kW/m2

Therefore our critical linear heat rate is 23.6 kW/ft – well below heater output

Page 17: Boiling Water Test Loop University  of  Idaho

17

Design Concerns

Line heater Outlet steam management Pump life Control system Safety Costs

Page 18: Boiling Water Test Loop University  of  Idaho

18

Total Cost Cartridge Heater: $200 Sight Glass/Test tube: $600 Heater: $1000 Heater Control: N/A Pump: $350 Pump Motor and Speed Control: N/A Heat Exchanger: $1100 Expansion Tank: $800 Stainless Steel Tubing 30 ft: $150 Fittings: $450 Mounting System: $350 Tubing Insulation: $100 Sensors: N/A

Total≈ $5100 + sensors, pump motor, and sensors/control

Page 19: Boiling Water Test Loop University  of  Idaho

19

Spring 2010 Timeline

Detailed design package completed by January 29

All parts ordered by February 5. Apparatus built by April 9. Trouble shooting and Testing April 16 –

May 7

Page 20: Boiling Water Test Loop University  of  Idaho

20

SpecificaitonsDescription Function Specification

1 Test Section Heater Simulates nuclear fuel rod. 220 V and 300 W/in2

2 Transparent Test Section Allows a person to see the boiling regime on the heater

Polysulfone plastic, operates at 295 ±5 F and vapor pressure of water at 295 ± 5 F.

3. Line Heater Adds energy to the water so that the quality of the water at the test section inlet can be adjusted.

Operates at vapor pressure of water at 295 ± 5 F, and has a 15 kW capacity.

4 Pump Pressurizes test section and circulates water

Operates at the vapor pressure of water at 295 ± 5 ˚F and can support the head seen in the system while maintaining the satisfying a flow rate varying from 0.0-3.0 gpm.

5 Heat Exchanger Takes energy out of the circulating water

Operates at vapor pressure of water at 295 ±5 F and removes up to 20 kW energy from water.

6 Expansion Tank Allows for expansion of the water in the loop when vapor occurs

Operates at vapor pressure of water at 295 ±5 F and supplies excess volume in loop for steam expansion.

Temp. Elements Measures the temperature at different places in the loop.

Operates at vapor pressure of water at 295 ±5 F sends an electrical signal which can be input to a data acquisition system. Likely a J type thermo couple.

Pressure Elements Measures the pressure at different places in the loop.

Operates at vapor pressure of water at 295 ± 5 F and sends an electrical signal which can be input to a data acquisition system.