B.M.P. DOORS LTD INDUSTRIAL RAPID DOORS
Web site : www.bmpdoors.co.uk e-mail : [email protected]
INSTALLATION MANUAL
Read this manual carefully before installing the product
The service of installation must be performed only by authorized personnel and in accordance with national wiring standards.
After reading the entire manual, keep it for future reference.
IMPORTANT
EN
GL
ISH
THERMICHROLL KOMBY
Operating instruction
Installation manual 2
INSTALLATION INSTRUCTIONS
- Always use a power circuit specifically dedicated to the door. For wiring follow the manufacturer's instructions.
- Tighten the screws of the electrical terminals to prevent loosening. - Make sure the power source has the required capacity. - Make sure the thickness of the cable conforms to what is stated in the
specification of the power source. - Never install a differential circuit breaker in wet or damp areas.
EQUIPMENT NEEDED
1 Tape measure 10 Level
2 Suitable lifting equipment (Genie, Forklift, Scissor Lift etc)
11 Set of spanners (17 mm, 13 mm, 10 mm, 8 mm)
3 Screwdriver set
12 Tester
4 Steel drill 13 Hammer
5 Hammer drill 14 Cordless screwdriver
6 Drill bits (Steel and concrete) 15 Grinder
7 Scissors 16 Silicone gun
8 Cable cutters
17 Pliers
9 Vices / Clamps 18 Set of Allen keys
Elevator Forklift WITH INTENTION TO CONTINUOSLY IMPROVE ITS SERVICE, B.M.P. SRL. RESERVES
THE RIGHT TO CHANGE THIS MANUAL AT ANY TIME, WITHOUT PRIOR NOTICE.
IMAGES USED IN THIS MANUAL MAY BE SLIGHTLY DIFFERENT FROM YOUR PRODUCT AND ARE USED FOR ILLUSTRATIVE PURPOSES ONLY.
Operating instruction
installation manual 3
ASSEMBLY OF THE MECANICAL PART
Door parts placed on the ground
Attach the base plates to the wall.
Fixing points.
Operating instruction
Installation manual 4
ROLL-UP SHUTTER DOOR PLATE HOLDER ASSEMBLY
Motor side
Bearing side - 30
Bearing Side - 40
Fix the Dynamicroll® support plates to the Roll-Up Shutter plate holders.
Operating instruction
installation manual 5
Rotate the motor using the chain, until it reaches the horizontal position.
Lift up and install the roll-up shutter.
Insert the bearing on the opposite side of the shaft.
Assemble the components of the Dynamicroll® door.
Operating instruction
Installation manual 6
1
INFRARED PHOTOCELLS - BP100
NOTE: IN CASE OF OTHER PHOTOELECTRIC SENSORS INSTALLED NEARBY,
YOU MAY EXPERIENCE DIFFICULTIES DUE UNCONTROLLED BEAM REFLECTIONS.
CONTROL BOARD
LEGEND
1 CONTROL CARD 6 MOTOR BRAKE TERMINAL FRAME (N°30-31) + FLASHING LIGHTS (N°29-30)
2 CONTROL CABINET 7 CONTROL CABINET LOCK 3 MOTOR TERMINALS (U-V-W) 8 START BUTTON 4 ISOLATOR 9 EMERGENCY BUTTON 5 EARTH TERMINAL 10
2
3
4 5
6
7
8
9
1
Operating instruction
installation manual 7
CONTROL CARD TERMINAL WITH LIMIT SWITCH
Jumpers inputs N.C. not used
Terminal N°
CONNECTION
1 +12V DC 100mA max. 2 0 V DC 100mA max. 3 Not used 4 5
SIGNAL - (option used 20.300) door open signal
- (option used 40.300) door close signal 6 Not used 7 Photocell/safety sensor or safety edge N.C. 8 Opening command, radar, push button, pull cord etc N.O. 9 Not used 10 Not used 11 Start opening (standard) / closing option in use 000008
N.O. 12 Pedestrian start N.O. 13 Common inputs (+12Vdc) 14 Photocell N.C. 15 Common inputs (+12Vdc) 16 Stop N.C. 17 Slow down opening limit switch N.C. 18 Slow down closing limit switch N.C. 19 Opening limit switch N.C. 20 Closing limit switch N.C. 21 24 V ac power. Accessories 300mA max. 22 24 V ac power. Accessories 300mA max.
32-33 SIGNAL: open door signal
Terminal N°
CONNECTION
23 Motor phase U 24 Motor phase V 25 Motor phase W 26 Power phase 230Vac 27 Neutral phase 230Vac 28 GROUNDING TERMINAL 29 Flashing light 230VDC 30 Flashing light/brake phase (COMMON) 31 Brake 105VDC
Operating instruction
Installation manual 8
PRE-WIRING WITH LIMIT SWITCH
Operating instruction
installation manual 9
CONTROL CARD TERMINAL WITH ENCODER
Jumpers inputs N.C. not used (no jumpers photocell with encoder)
Terminal N°
CONNECTION
1 +12v DC 100mA max. encoder red cable 2 0 V DC 100mA max. encoder black cable 3 Not used 4 5
SIGNAL - (option used 20.300) door open signal
- (option used 40.300) door close signal 6 Not used 7 Photocell/safety sensor or safety edge N.C. 8 Opening command, radar, push button, pull cord etc N.O. 9 Not used 10 Not used 11 Start opening (standard) / closing option in use 000008 N.O.
12 Pedestrian start N.O. 13 Common inputs (+12Vdc) 14 Photocell (no jumpers photocell with encoder) N.C. 15 Common inputs (+12Vdc) 16 Stop N.C. 17 Encoder green cable 18 Encoder yellow cable 19 Not used 20 Not used 21 24 V ac power. Accessories 300mA max. 22 24 V ac power. Accessories 300mA max.
32-33 SIGNAL (option used 20.300)closed door signal
Terminal N°
CONNECTION
23 Motor phase U 24 Motor phase V 25 Motor phase W 26 Power phas e 230Vac 27 Neutral phase 230Vac 28 GROUNDING TERMINAL 29 Flashing lights 230VDC 30 Flashing lights/brake phase (COMMON) 31 Brake 105VDC
Operating instruction
Installation manual 10
PRE-WIRING WITH ENCODER
SCREEN ENCODER CABLE MUST BE CONNECTED TO TERMINAL
NO. 2 (0Vdc) IN THE CARD
Operating instruction
installation manual 11
SIGNAL LED
LD2 LED CLOSING LIMIT SWITCH
LD3 LED OPENING LIMIT SWITCH
LD4 LED SLOW DOWN CLOSING LIMIT SWITCH
LD5 LED SLOW DOWN OPENING LIMIT SWITCH
LD6 LED STOP
LD7 LED ALIGNED PHOTOCELL
LD8 LED PEDESTRIAN START
LD9 LED START
LD10 NOT USED
LD11 NOT USED
LD12 LED OPENING COMMAND
LD13 LED PHOTOCELL/SAFETY SENSOR
Operating instruction
Installation manual 12
CURTAIN INSERTION
1
2
CURTAIN TENSIONING AND COLUMNS FIXING
GUIDA
MOLLA
MONTANTE
TELO
OPEN ING
BUTTON (P2)
PROGR. BUTTON
(P3)
CLOSINGBUTTON
(P1)
MAX!
P1 OPEN P2 CLOSE
12
13
REVERSE
Operating instruction
installation manual 13
B
500
LIMIT SWITCH
OPEN (green)
SLOW DOWN OPENING (white)
SLOW DOWN CLOSING (grey)
CLOSE (brown)
COMMON (yellow)
ADJUSTING SCREWS
CAMMES
Operating instruction
Installation manual 14
LIMIT SWITCH SETTINGS
SETTING OPEN GREEN CABLE (C1)
1) SETTING SLOW DOWN OPENING WHITE CABLE(C2)
2) SETTING SLOW DOWN CLOSING GREY CABLE (C3)
3) SETTING CLOSE BROWN CABLE (C4)
300-
400
mm
100
mm
PHOTOCELL
LED OK
LED OK
LED OK
LED OK
Operating instruction
installation manual 15
PLANNING WITH LIMIT SWITCH
PRESS START BUTTON
FAST FLASHING HOLD FOR 10 SECONDS
DOOR OPEN
WAIT BREAK TIME PRESS START
END
LED OK
1 2
3 4
5 6
7 8
DOOR CLOSE
OK
Operating instruction
Installation manual 16
SETTING WITH ENCODER
PRESS
FAST FLASHING
PRESS
HOLD FOR 20 SECONDS
WAIT BREAK TIME
CONFIRM BREAK TIME
START
DOOR CLOSE
CURTAIN STOPS AT PHOTOCELLS LEVEL
1 2
4 3
5 6
8 7
9 10
CONFIRM THAT THE DOOR IS OPEN
OK
PRESS
PRESS
Operating instruction
installation manual 17
SETTING POSITION OPEN AND CLOSE WITH PROGRAMMER (only with encoder)
ONLY AFTER PROGRAMMING THE ENCODER
INSERT PROGRAMMER IN THE CONTROL CARD PLUG
(*) OPEN RIDE VALUE INDICATIVE ONLY
(*) CLOSE RIDE VALUE INDICATIVE ONLY
*+/- 10qc = ~ 1cm
* +/- 10qc = ~ 1cm
Operating instruction
Installation manual 18
ATTENTION: CORRECT POSITION CLOSED DOOR
ATTENTION: CORRECT POSITION OPENED DOOR
YES NO BALLAST TUBE
YES NO
Operating instruction
installation manual 19
SETTING HIGHEST SPEED (System parameters)
MOTOR TYPE : 1,5 KW 50/60Hz
PARAMETER FREQUENCY MAX SPEED HZ OPEN FREQUENCY 70HZ
CLOSE FREQUENCY 40HZ SLOW DOWN OPEN FREQUENCY 30HZ
SLOW DOWN CLOSE FREQUENCY 30HZ
MOTOR TYPE : 0,75 KW 50Hz
PARAMETER FREQUENCY MAX SPEED HZ OPEN FREQUENCY 60HZ
CLOSE FREQUENCY 30HZ SLOW DOWN OPEN FREQUENCY 25HZ
SLOW DOWN CLOSE FREQUENCY 25HZ
PARAMETERS TO BE RESPECTED (System status)
(*) IF THE VALUE EXCEEDS THAT SHOWN LOWER OPEN FREQUENCY. (*) IF VALUE DROPS BELOW THATSHOWN CHECK THE POWER SUPPLY CIRCUIT (CABLES SECTION 2.5MM FROM MAIN SOURCE, POWER SUPPLY VOLTAGE ETC.)
POWER MOTOR (Opening door)
1.5KW = MAX 8.5A (*)
0.75KW = MAX 4.5A (*)
POWER BUS VOLTAGE (Opening door)
MIN 280V(*)
Operating instruction
Installation manual 20
PLANNING PEDESTRIAN OPENING WITH ENCODER
END
SLOWLY FLASH
PRESS WITHIN 5 SECONDS
WAIT BREAK TIME
4 3
5 6
8 7
CONFIRM PEDESTRIAN POSITION
PRESS
PEDESTRIAN HEIGHT
DOOR CLOSE
PRESS
PRESS
2 1
CONFIRM BREAK TIME
Operating instruction
installation manual 21
PLANNING PEDESTRIAN OPENING WITH LIMIT SWITCH
FAST FLASH
PRESS
PRESS 10/15 SEC.
CONFIRM BREAK TIME
WAIT BREAK TIME
DOOR CLOSE
END
1 2
4 3
5 6
8 7
CONFIRM PEDESTRIAN POSITION
PRESS
PRESS
PRESS
PEDESTRIAN HEIGHT
Operating instruction
Installation manual 22
CONNECTIONS WITHOUT ELECTRICAL PRE WIRING
WIRING CABLE:
Motor cable 3x1.5 screened cable (screen grounded)
Limit switch cable (where installed) 5x0,5 Encoder cable (where installed) 4x0,5 screened cable
(screen grounded) Break cable 2x1,00 screened cable
(screen grounded) Flashing light cable 2x1,00 screened cable
(screen grounded) Photocell receiver cable 3x0,5
Photocell transmitter cable 2x0,5 Motor safety switch cable 2x0.5
Button/anchors cable 2x0,5 Radar cable 4x0,5
Cable lines:
- First tube line: motor, brake and flashing light cable ( High voltage 230V)
- Second tube line: Photocell ,limit switch, push buttons, radar etc. ( Low voltage 12-24V)
BMP srl IS NOT RESPONSIBLE IF THE DOOR DOES NOT WORK WHEN THE REQUIREMENTS ARE NOT OBSERVED
MOTOR “TRIANGLE CONNECTION”
Operating instruction
installation manual 23
DOOR ELECTRICAL SYSTEM
MOTOR BOX WIRING
Operating instruction
Installation manual 24
SENSOR NO TOUCH
Operating instruction
installation manual 25
LIMIT SWITCH CONNECTION
C1 OPENING LIMIT SWITCH
C2 SLOW DOWN OPENING LIMIT SWITCH
C3 SLOW DOWN CLOSING LIMIT SWITCH
C4 CLOSING LIMIT SWITCH
F1 CONNECTION N.C.
F2 CONNECTION N.C.
F3 CONNECTION N.C.
F4 CONNECTION N.C.FC CONNECTION COMMON
DIP SWITCH (DS)
- ADJUSTABLE AUTOMATIC CLOSURE To set this function put the dip Switch1 to ON (*) Functioning mode set by the factory
- STEP BY STEP
To set this function put the dip switch 1 to OFF
ATTENTION!!! THIS FUNCTION DOES NOT PERFORM THE AUTOMATIC CLOSURE FUNCTIONING WITH “NEGATIVE” ENGINE BRAKE
To set this function put the dip switch 2 to OFF
FUNCTIONING WITH “POSITIVE” ENGINE BRAKE (*)
To set this function put the dip switch 2 to ON
(*) set it only if you have a door with “COUNTERWEIGHT” to open the door in case of power cut to the control board
Operating instruction
Installation manual 26
SAFETY RESISTIVE EDGE RECEIVER TRANSMITTER RESISTIVE EDGE
ATTENTION ALWAYS CHECK THE RESISTIVITY BEFORE CONNECTING TRANSMITTER AND RECEIVER
TRANSMITTER CONNECTION
NO JUMPER
PROG
RESISTIVE EDGE INSIDE CURTAIN
RESISTIVE EDGE VALUE BETWEEN
8.1 AND 8.4 kΩ (Tester on 20kΩ)
Operating instruction
installation manual 27
RECEIVER CONNECTION
CODE MEMORY
A) Press PROG (transmitter) until you hear a beep B) Press PROG (in 5 sec max) (receiver) until you hear a beep C) Wait 10/15 sec D) LD 13 (resistive edge) “ON”
MAXIMUM DISTANCE BETWEEN RECEIVER AND TRANSMITTER 8 METERS
TRANSMITTER
Operating instruction
Installation manual 28
MANUAL OPERATION
RESET CONTROL CARD
SAFETY GENERAL RULES
Before any intervention the maintenance engineer must:
o Cordon off area and affix the right signs in order to signal the maintenance works on the door
o Check that the electricity power is disconnected before you start the maintenance o Check that they fully understand the maintenance required and have read and
understand this manual o
The maintenance man can’t use the electrical fittings without a declaration of his proved experience.
Don’t allow unauthorized people to repair or maintenance the doors. Read the manual before maintaining the doors. During maintenance don’t use heat sources that could start fires. During maintenance do not weld The presence of the maintenance staff around the door must be limited. The presence of other people around the door is necessary only to support the maintenance staff
PERIODICAL CHECKS AND MAINTENANCE
CLOSE BUTTON
(P1)
OPEN BUTTON
(P2)
- SWITCH OFF THE POWER TO THE CONTROL CARD - PRESS AND HOLD BUTTONS P1 & P2 - SWITCH THE POWER BACK ON TO THE CONTROL
CARD WHILST STILL PRESSING THE BUTTONS P1 & P2 - KEEP PRESSED FOR 5-6 SECONDS - RESET COMPLETE, RESET ENCODER IF FITTED
Operating instruction
installation manual 29
GENERAL CLEANING AND MAINTENANCE The general maintenance operations can be carried out by the user. The maintenance and cleaning of the door is necessary to ensure the smooth operation and continued reliability in operation of the door. COMPONENT DESCRIPTION PERIODICITY
Structure
Verify that the structure is securely fixed to the wall in order to avoid incidents. Clean with soft cloth any dirt or dust build up ( use soap and water if required ) If there is ice on the structure immediately remove it
Six-month
Photocell and radar
Clean with soft cloth ( in dusty areas could be necessary to clean more frequently the photocells: dust on photocells could cause malfunctioning of the photocells)
Six-month
Vision Window Clean the window with a soft cloth and if necessary with soap and water ( do not use any solvent that could damage the window) Six-month
Curtain Check the condition of the belts and of the curtain. Clean the curtain with a soft cloth and if necessary with soap and water ( do not use any solvent that could damage the curtain)
Six-month
Operating instruction
Installation manual 30
CHECK, PLANNED INSPECTIONS AND MAINTENANCE Only the maintenance staff or authorized people could do checks, planned inspections and planned maintenance. These operations are necessary for the validity of the warranty INTERVENTION POINT
DESCRIPTION PERIODICITY
Structure
- Check the condition of the fixing frames, and all fixings are tight that secure the frame to the fixing face
- Check that there isn’t any structural damage due to impact or collisions
Six-month
Electrical components
- Check the electrical connections in the control board and check that there is no moisture inside the cabinet.
- Check the electrical connections in the junction box and check that there is no moisture present
- Check the condition and operation of the safety components (photocells, safety edge and emergency button etc)
- Check the condition and operation of the opening components (opening buttons, radars, loop detectors etc)
- Check that all the electrical cables are in good condition.
Six-month
Mechanical components
- Check the condition of the motor - Check the condition of the motor brake - Check the wear and tension of the drive chain from the
motor to the barrel (where applicable) - Check the condition of the Gearbox: eg oil leaks, fixing to
the motor, fixing of the structure. - Check the condition of the limit switch box: eg wear of the
drive chain, wear and fixing of the cogs, the correct functioning of the cams and micro switches.
- Check the tightness of all bolts for any part of the structure.
- Check the condition of the main barrel in the heading - Check the condition and grease the bearings. - Check the condition of the anti wear washers on the
columns - Check the condition and clean the guides ( on the
Dynamic doors) -
Six-month
Curtain
- Check the condition and wear of the curtain and in particular in the areas subject to rubbing.
- Check that there aren’t any tears on the curtain. - Check the condition and operation of the belts, lower and
upper fixing plates and of the loop belts( for the rapid pack doors)
- Check the condition of the curtain bars - Check the operation of the curtain rolling around the barrel
squarely - Check the tensioning of the curtain, the condition and
wear of the zips ( for the dynamic doors)
Six-month
Operating instruction
installation manual 31
PROBLEM SOLUTION
1 THE WARNING LIGHTS IN THE CONTROL BOARD DO NOT LIGHT UP
1 CHECK POWER SUPPLY ( 230 V )
1 CHECK FUSE
2 THE DOOR DOES NOT MOVE WITH P1 AND P2 BUTTON
2 CHECK SETTING MOTOR WITH PROGRAMMER (SETTING PARAMETERS – MOTOR TYPE ……kW)
2 RELEASE STOP BUTTON (LED 6 turned on)
2 CHECK MOTOR CONNECTION (triangle 230V three-phase, star 380V three-phase)
3 YOU CAN NOT COMPLETE THE SETTING OF THE CARD ( with encoder)
3 CHECK WITH PROGRAMMER PARAMETER OPTION IN USE 4300 FOR SINGLE PHOTOCELL 4380 FOR DOUBLE PHOTOCELL
3 RELEASE THE STOP BUTTON (LED 6 turned ON)
3 MOVE THE DOOR WITH BUTTON P1 AND P2 OF 40/ 50 cm AND LOCATE IT ON CLOSE POSITION ( this operation is useful to recognize the encoder )
3 VERIFY THAT THE LED LD13 (radio safety edge or sensor in the upper case) IS ON
3 IF NOT, MAKE JUMPERS 7 /13 AND CONTROL THEN THE SECURITY COMPONENTS
3 INVERT THE ENCODER CABLE (yellow with green )
3 FOR DOORS WITH UPPER PHOTOCELL CONTROL THAT LD 3 IS OFF WHEN THE DOOR IS CLOSE
4 YOU CAN NOT COMPLETE THE SETTING OF THE CARD
4 CONTROL THAT THE LIMIT SWITCH ARE CORRECTLY REGUALATED ( if slow down closing and closing limit switch are not pressed the card can not be set)
(with limit switch ) 4 VERIFY THAT THE LED LD13 (radio safety edge or sensor in the upper case) IS ON
4 VERIFY THAT THE LED LD7 (safety photocell ) IS ON
4 RELEASE STOP BUTTON (LED 6 turned on)
5 YOU CAN NOT COMPLETE THE SETTING OF THE RESISTIVE EDGE
5 VERIFY THAT THE JUMPER ON THE TRANSMITTER J1 IS TAKEN OFF
5 RESET THE OLD CODES (close the jumper "MR" press the PROG button until you hear a beeps tight series, then remove the jumper)
5 VERIFY WITH THE TESTER THE CHARGE OF THE TRANSMITTER BATTERIES
5 VERIFY IF THE RESISTENCE (8.2 KΩ) FOR THE CABLES THAT COME OUT FROM THE EDGE CHANGES IF YOU PRESS THE EDGE if it does not change control that the resistive band is perfectly flat for all the length of the black profile or take out the gum and control the integrity.
5 VERIFY THE CONNECTIONS OF THE RECEIVER
6 THE PHOTOCELL DOES NOT WORK ( LD 7 OFF)
6 VERIFY THE ALIGNMENT
6 VERIFY THE CONNECTION OF THE BLACK RECEIVER CABLE( brown +12Vdc) (blue 0V dc ) ( black: signal that it arrives to the terminal 14 in the local plant)
(the door does not close )
6 VERIFY THE CONNECTION OF THE TRANSMITTER GREY CABLE ( brown +12Vdc) (blue 0V dc)
( ATTENTION! If you invert the brown and blue cables you will damage the sensors)
7 THE ANTI-JAMMING SENSOR DOES NOT WORK (sensor) (the sensor does not light up)
7 VERIFY THE CONNECTION ( brown +12Vdc) (blue + white 0V dc ) ( black: signal that it arrives to the terminal 7 in the local plant)
Operating instruction
Installation manual 32
8 THE ANTI-JAMMING SENSOR DOES NOT WORK (sensor) (the door closes but the sensor does not work if I press it)
8 BRING THE SENSOR CLOSER TO THE CURTAIN
8 PUT THE SENSOR FRONTALLY TO THE TUBE AXIS
8 CONTROL THE CONNECTIONS ( brown +12Vdc) (blue 0V dc ) ( black connected to the cable 7 in the local plant)
9 THE DOOR STOPS AT THE PHOTOCELL LEVEL AND COMES BACK
9 REGULATE THE SLOWING DOWN LIMIT SWITCH: IT CLOSES 10 cm BEFORE THE PHOTOCELL ( the contact switch off the functioning )
10 THE DOOR CLOSES ONLY 50 cm AND THEN COMES BACK
10 INCREASE THE INTERVENTION TIME OF THE ANTI-JAMMING PHOTOCELL USING THE PROGRAMMER (PARAMETER SETTING- ANTI-JAMMING PHOTOCELL READING)
10 LOWER THE ANTI-JAMMING PHOTOCELL SENSOR
11 LD1 REMAINS ON( IN THE TOP LEFT-HAND )
11 VERIFIY THE FUSE
11 THE CARD IS DAMNAGED ( replace it)
12 THE DOOR DOES NOT CLOSE AUTOMATICALLY
12 VERIFY DIP 1 ( ON = automatic ) (OFF = manual )
12 CONTROL THE CORRECT FUNCTIONING OF THE SAFETY COMPONENTS ( LD 7 - LD 13- LD 6 on)
13 THE DOOR WORKS BUT SOMETIMES IT GETS STUCK (in any position)
13 VERIFY THE CORRECT SETTING OF THE MOTOR WITH THE PROGRAMMER (PARAMETER SETTING – TYPE OF MOTOR ……kW)
13 CONTROL THAT THE FLASHING LIGHTS WIRES OR THE MOTOR BRAKE WIRES ARE NOT IN THE SAME CABLE OF THE PHOTOCELL AND LIMIT SWITCH (interference problem) they must have their own cable and tube ,the 230V must be separated from 12- 24V
13 VERIFY WITH THE TESTER THAT THE CURRENT ISN’T LOWER THAN 220V (control when the door’s working) if the current is lower than 220V control the input
13 VERIFY WITH THE PROGRAMMER THAT THE BUS VOLTAGE IS NOT LOWER THAN 300V (SYSTEM CONDITION – BUS VOLTAGE) (control when the door’s working) if the voltage is lower than 300V control the input.
13 VERIFY WITH THE PRORAMMER THE MOTOR UPTAKE (SYSTEM CONDITION- MOTOR CURRENT with motor 0,75kW can’t be higher than 7A;with motor 1,5 kW can’t be higher than 9A, control when the door’s working) if the door exceeds the threshold lower the opening HZ
14 THE PHOTOCELL DOES NOT WORK (the door closes but the photocell doesn’t reverse the curtain)
14 CONTROL THAT IN THE VICINITY THERE ARE NOT ANY OTHER PHOTOCELLS THAT COULD CAUSE REFLECTION (try to darken the photocells)
14 CONTROL THAT WITH THE PHOTOCELL CABLES THERE ARE NOT ANY HIGH VOLTAGE CABLES (motor ,motor brake, flashing lights, power line) (take to the control board separated cables in different pipes, separate the low voltage 12-24V from the high voltage ≥ 100V)
14 PUT THE MINUS OF THE RECEIVER (black cable, blue wire) ground
15 WITH OPEN DOOR (locked) THE CURTAIN SLOW DOWN
15 SET THE MOTOR BRAKE (remove the fan cover and close of a quarter turn of the dial brake adjustment, then make tests to reach the optimum)
Information needed:
- Personal information company (or owner of the door) - Door data (serial NO.) - Description of the problem - Eventually photos
Spares or Technical support
Operating instruction
installation manual 33
- RUN OPTION with control card BMP1-VO1;BMP1-V03 end BMP2-V03 WARNING: logic board is set to the value of 200 (200 DEFAULT VALUE) by the factory.
- Further values must to be added.
FUNCTION DESCRIPTION
VALUE TO INSERT ON
“RUN OPTION”
Enable ups batteries: function opens after fixed time 2 Enable ups batteries: function opens after start command 4
Start button: it closes but it doesn’t open 8 Step cycle: closing the door to start stops mid 10
“Pause time” and “queue time after transit” individually considered with zero (0) break time only 20
Move the pedestrian start on internal radar: when you need pedestrian + ups 40 It disables current control brake before starting 100
It disables timeout control alarms on movements and other inconsistencies DEFAULT SETTING 200
Pedestrian start: it opens but doesn’t close, it only clears pause time 400 It disables unplugged encoder alarm 800
Frost protection function: maneuver every 15 minutes 1.000 Frost protection function: running every 60 minutes 2.000
Frost protection function: adjustable time You write the time in “queue time after transit” 3.000
Encoder recognized automatically to the first movement in jog DEFAULT SETTING 4.000
It reverses relay outputs for signal door state Terminals 4-5 = door open
Terminals 32-33 = door closed 20.000
It reverses relay outputs for signal door state Terminals 4-5 = door closed Terminals 32-33 = door open
DEFAULT SETTING
INTELOOK for BMP1-V03 end BMP2-V03(new models) Enable interlaced operation connect:
Terminal no. 4 of card “1” with terminal no. 12 of the card “2” Terminal no. 5 of card “1” with terminal free of the card “2”
Terminal no. 4 of card “2” with terminal no. 12 of the card “1” Terminal no. 5 of card “2” with terminal free of the card “1”
Write in the lcd menu "bussola/c.remoto terminal n°”….” The number of terminal used
80.000
INTELOOK for BMP1-V01(running model) Enable interlaced operation connect:
Terminal no. 4 of card “1” with terminal no. 12 of the card “2” Terminal no. 5 of card “1” with terminal no 13 of the card “2” Terminal no. 4 of card “2” with terminal no. 12 of the card “1” Terminal no. 5 of card “2” with terminal no. 13 of the card “1”
80.000
It disables automatic alignment (after blackouts to return power) With encoders and 1 single photocell 100.000
If you inserted a undervoltage motor heating (use only with installations in low temperature 200.000
On pedestrian cycle , when the door is open, It closes relay door state and disables automatic 400.000
The radar does not open it only performs reversals in closing 1.000.000