1
Blur Unblurred – a Mini-Tutorial Hans Strasburger 1,2 , Michael Bach 3,4 , & Sven P. Heinrich 5,6 1 Inst. of Med. Psychology, Goethestr. 31, München, Germany; www.hans.strasburger.de , 2 Dept. of Med. Psychology and Med. Sociology, Georg-August University, Göttingen, Germany 3 Section for Functional Vision Research, Eye Center, Medical Center, University of Freiburg, Germany; [email protected] , 4 Faculty of Medicine, University of Freiburg, Germany 5 Section for Functional Vision Research, Eye Center, Medical Center, University of Freiburg, Germany; [email protected] , 6 Faculty of Medicine, University of Freiburg, Germany Summary •Optical blur from defocus (=dioptric defocus), often confused with low-pass filtering, can occur with myopia, presbyopia or misaccommodation, or purposefully with plus-lenses to study effects of optical degradation. •Perhaps surprisingly, the dioptric blur kernel is simply a cylinder. •The blur circle’s diameter is ~ pupil size · defocus. Its size can also be assessed from the near or far point. •There is a simple formula to derive decimal visual acuity from defocus. James Jurin (1738) A “circle of dissipation” on a ring stimulus. Jurin’s eye model for accommodation Spurious resolution Blur-Disk & pupil size & defocus Visual acuity & defocus References Blur kernel shapes Dioptric blur The effect of defocus on a frequency-sweep sine-wave grating. The contrast transfer factor for a defocused periodic sinusoidal grating. At 0.5 D defocus, contrast is zero. D p b mm 057 . 0 Gaussian blur Original stimulus Defocus "First-order" low-pass Defocus Gauss "First-order" low-pass Dioptric blur; disk kernel Ø= letter height P f df b stim stim foc stim d d d p b Blur disk diameter (°) 0,0 0,4 0,8 1,2 1,6 0 2 4 6 8 Defocus (D) Blur Disk Diameter (°)  Blendowske, R. (2015). Unaided visual acuity and blur: a simple model. Optometry and Vision Science, 92(6), e121-e125. Jurin, J. (1738). An essay on distinct and indistinct vision. In A compleat system of opticks in four books, viz. a popular, a mathematical a mechanical, and a philosophical treatise (pp. 115-171). Cambridge: Published by the author. Smith, G. (1982a). Angular Diameter of Defocus Blur Discs. American Journal of Optometry & Physiological Optics, 59(11), 885-889. Smith, G. (1982b). Ocular defocus, spurious resolution and contrast reversal. Ophthalmic and Physiological Optics, 2(1), 5-23. Watson, A. B., & Yellott, J. I. (2012). A unified formula for light-adapted pupil size. Journal of Vision, 12(10), 12. Thanks to Nick Wade for pointing out Jurin and language corrections. The derivation is given by Smith (1982a) using the simplified Gullstrand eye. See separate sheet. 0,0 0,2 0,4 0,6 0,8 1,0 0 1 2 3 4 Defocus (D) Degradation of acuity, v rel = v / v bc 2 1 / D v v bc 2 1 1 / D v v bc Blur disk in stimulus space when the target is too near or too far. p: pupil size A target approaching from the right. Blue line : Accommodation Red line : Too near Circle : JND b°: blur disk diameter in deg p mm : pupil size in mm D: Defocus in diopters v/v bc : Acuity degradation D: Defocus in diopters To induce blur Jurin proposed bringing a stimulus closer or farther than accommodation allows, and noticed physical blur is not perceptual blur. for small D Effect of blur on Sloan letters: original letters and PSFs PSF with exponential drop-off Energy is spread over a wide spatial range Gaussian blur. Blurred images increased in contrast. Isolumes = luminance steps of 7 %points Example: 1dpt decreases acuity to ½ its value Exponential lowpass Gaussian lowpass

Blur Unblurred – a Mini-Tutorial Summary Spurious ...hans-strasburger.userweb.mwn.de/reprints/ecvp_2016.pdf · Blur Unblurred – a Mini-Tutorial Hans Strasburger1,2, Michael Bach3,4,

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Blur Unblurred – a Mini-Tutorial Summary Spurious ...hans-strasburger.userweb.mwn.de/reprints/ecvp_2016.pdf · Blur Unblurred – a Mini-Tutorial Hans Strasburger1,2, Michael Bach3,4,

Blur Unblurred – a Mini-TutorialHans Strasburger1,2, Michael Bach3,4, & Sven P. Heinrich5,6

1Inst. of Med. Psychology, Goethestr. 31, München, Germany; www.hans.strasburger.de, 2Dept. of Med. Psychology and Med. Sociology, Georg-August University, Göttingen, Germany3Section for Functional Vision Research, Eye Center, Medical Center, University of Freiburg, Germany; [email protected], 4Faculty of Medicine, University of Freiburg, Germany5Section for Functional Vision Research, Eye Center, Medical Center, University of Freiburg, Germany; [email protected], 6Faculty of Medicine, University of Freiburg, Germany

Summary•Optical blur from defocus (=dioptric defocus), often confused with low-pass filtering, can occur with myopia, presbyopia or misaccommodation, or purposefully with plus-lenses to study effects of optical degradation.•Perhaps surprisingly, the dioptric blur kernel is simply a cylinder.•The blur circle’s diameter is ~ pupil size · defocus. Its size can also be assessed from the near or far point.•There is a simple formula to derive decimal visual acuity from defocus.

James Jurin (1738)

A “circle of dissipation” on a ring stimulus.

Jurin’s eye model for accommodation

Spurious resolution

Blur-Disk & pupil size & defocus

Visual acuity & defocus

ReferencesBlur kernel shapes

Dioptricblur

The effect of defocus on a frequency-sweep sine-wave grating.

The contrast transfer factor for a defocused periodic sinusoidal grating.

At 0.5 D defocus, contrast is zero.

Dpb mm057.0

Gau

ssia

n bl

urO

rigin

al s

timul

usD

efoc

us"F

irst-

orde

r" lo

w-p

ass

Defocus

Gauss

"First-order"low-pass

Dioptric blur;disk kernel Ø= letter height

P

f df

b

stim

stimfocstim d

ddpb

Blur disk diameter (°)

0,0

0,4

0,8

1,2

1,6

0 2 4 6 8

Defocus (D)

 Blu

r Dis

k D

iam

eter

(°) 

Blendowske, R. (2015). Unaided visual acuity and blur: a simple model. Optometry and Vision Science, 92(6), e121-e125.

Jurin, J. (1738). An essay on distinct and indistinct vision. In A compleat system of opticks in four books, viz. a popular, a mathematical a mechanical, and a philosophical treatise (pp. 115-171). Cambridge: Published by the author.

Smith, G. (1982a). Angular Diameter of Defocus Blur Discs. American Journal of Optometry & Physiological Optics, 59(11), 885-889.

Smith, G. (1982b). Ocular defocus, spurious resolution and contrast reversal. Ophthalmic and Physiological Optics, 2(1), 5-23.

Watson, A. B., & Yellott, J. I. (2012). A unified formula for light-adapted pupil size. Journal of Vision, 12(10), 12.

Thanks to Nick Wade for pointing out Jurin and language corrections.

The derivation is given by Smith (1982a) using the simplified Gullstrand eye.See separate sheet.

0,0

0,2

0,4

0,6

0,8

1,0

0 1 2 3 4Defocus (D)

Deg

rada

tion

of a

cuity

, vre

l = v

/ v b

c

21/ Dvv bc

211/D

vv bc

Blur disk in stimulus space when the target is too near or too far.p: pupil size

A target approaching from the right.Blue line: AccommodationRed line: Too nearCircle: JND

b°: blur disk diameter in degpmm: pupil size in mmD: Defocus in diopters

v/vbc: Acuity degradationD: Defocus in diopters

To induce blur Jurin proposed bringing a stimulus closer or farther than accommodation allows, and noticed physical blur is not perceptual blur.

for small D

Effect of blur on Sloan letters: original letters and PSFs

PSF with exponential drop-offEnergy is spread over a wide spatial range

Gaussian blur. Blurred images increased in contrast. Isolumes = luminance steps of 7 %points

Example:1dpt decreases acuity to ½ its value

Exponentiallowpass

Gaussianlowpass