2 Technical info
Blow Heaters
1 Product Description
SKOV A/S supplies direct-fired blow heaters as a supplement to or as a replacement for water-based
indirect-fired heating systems.
Direct-fired means that the generation of heat takes place as a result of direct, open combustion of gas
in the house section itself.
Please note that some countries prohibit heating of livestock houses by means of direct-fired blow
heaters and that some countries require special approvals of the various types of burners. Blow heaters
included in the SKOV A/S product range are not to be sold in North America due to lacking UL
approval.
Heat rating Product Type
14 kW
GP 14 kW, NG
GP 14 kW, LPG
40 kW
GP 40 kW, NG
GP 40 kW, LPG
70 kW
GP 70 kW, LPG
GP 70 kW, NG
95 kW
GP 95 kW, LPG
GP 95 kW, NG
Table 1: Lists the variants of blow heaters used by SKOV A/S.
All sizes of blow heaters are available in two variants - natural gas fired and LPG/Propane fired.
• The blow heaters are designed specifically for application in livestock houses.
• Each blow heater is equipped with an independent controller - BCU (Burner Control Unit).
• The BCU controls and monitors that the burner works correctly as regards safety and output.
• An adjustment procedure as well as an individual test of the blow heaters has been carried out
by the manufacturer.
• The on/off heating function incorporated in the blow heaters is controlled by the DOL climate
computers from SKOV A/S.
• Comes with connection kit for natural gas or LPG/Propane gas.
• The gas grid, pipes, controller and storage tanks are not supplied by SKOV A/S.
• Blow heaters can be used as on/off air circulators, when heating is not required.
Technical info 3
Blow Heaters
1.1 Method of Operation
The blow heaters circulate the housing air by means of the built-in fans.
A signal is transmitted from the DOL climate computer from SKOV to the blow heaters to
make them switch on; the climate computer cuts off the signal when the heat requirement has
been covered.
Direct-fired blow heaters cause emission of waste products generated in the combustion
process into the housing air of the livestock house. This brings about a need for higher
minimum ventilation and a higher fuel consumption compared to waterborne heating.
Figure 1: The figure illustrates the application of blow heaters and air circulators in broiler houses. The
blow heaters are suspended from the ceiling below the air inlets and thus heat up the incoming
air.
Blow heater
Air circulator
4 Technical info
Blow Heaters
2 Product Survey
Blow heater
All blow heaters come with a standard suspension kit including 0.8m chain per suspension
point, hook and snap hooks. Each unit has 2, 3 or 4 suspension points respectively.
410138 Blow heater GP 14 kW, NG, 230V 50 Hz
410139 Blow heater GP 14 kW, LPG 230V 50 Hz
Applies to both:
Range of air jet: 10 m
Weight: 13.0 kg
Gas connection: ½” sleeve
410130 Blow heater GP 40 kW, NG, 230V 50 Hz
410131 Blow heater GP 40 kW, LPG 230V 50 Hz
Applies to both:
Range of air jet: 40 m
Weight: 26.8 kg
Gas connection: ½” sleeve
410132 Blow heater GP 70 kW, LPG 230V 50 Hz
410133 Blow heater GP 70 kW, NG, 230V 50 Hz
Applies to both:
Range of air jet: 50 m
Weight: 26.8 kg
Gas connection: ¾” nipple
410134 Blow heater GP 95 kW, LPG 230V 50 Hz
410135 Blow heater GP 95 kW, NG, 230V 50 Hz
Applies to both:
Range of air jet: 40 m
Weight: 38.4 kg
Gas connection: ¾” nipple
Technical info 5
Blow Heaters
Accessories for blow heater
410156 Connection kit blow heater ¾” 1.5m
Connection kit for GP70 and GP95, natural gas
Including ball plug valve ¾” sleeve
410157 Connection kit blow heater ½” 1.5m
Connection kit for GP14 to GP40, natural gas
Including ball plug valve ½” sleeve
410158 Connection kit blow heater LPG 1.5m
Connection kit for GP14/40/70/95 LPG
Complete as illustrated including controller. Supply
pressure to the controller must be between 0.53 and
1.9 bar.
A 6mm hose connection is required on the supply.
For supply of LPC/Propane.
This connection kit is able to regulate the pressure
on the gas grid down to the maximum permissible
supply pressure.
Order one set per blow heater.
410159 Suspension set incl. hoist for blow heater
Contains fixing rail and mounting set.
Order one set per blow heater.
410161 Suspension set for blow heater
Contains fixing rail and mounting set.
Order one set per blow heater.
530302 Loctite liquid packing, gas 577 50 ml
All-purpose liquid packing.
Well suited for mounting in places of low
temperatures, e.g. outdoors.
DVGW approved (EN 751-1)
WRC approved (BS 6920): 0711506
Max. pipe dimension: 3"
Disassembling, resistance to fracture: Medium
Application: -50°C - +150°C
Consumption amounts to one bottle / 20 blow
heaters.
6 Technical info
Blow Heaters
Air circulator
445044 DB 465 air circulator 230V 50Hz stepless
445093 DB 465 air circulator 230V 60Hz stepless
Is primarily used for air circulation.
Air circulator which can contribute to reduce
temperature difference.
Can be adjusted steplessly for example using DOL 31.
445043 DB 620 air circulator 230V 50Hz stepless
Is primarily used for air circulation.
Air circulator which can contribute to reduce
temperature difference.
Can be adjusted steplessly for example using DOL 31.
Accessories for air circulator
445047 Suspension parts for air circul, fixed
Is used for suspension of the above air circulators in
the ceiling.
Cannot be adjusted in height.
445048 Suspension parts for air circ., hoist
Is used for suspension of the above air circulators in
the ceiling.
Can be adjusted in height to facilitate positioning and
service.
Technical info 7
Blow Heaters
3 Technical Data
Article no. 410138 410130 410133 410135 410139 410131 410132 410134
Type GP 14 kW, NG
GP 40 kW, NG
GP 70 kW, NG
GP 95 kW, NG
GP 14 kW, LPG
GP 40 kW, LPG
GP 70 kW, LPG
GP 95 kW, LPG
Electrical Setup
Voltage [V]
230 230 230 230 230 230 230 230
Frequency [Hz]
50 50 50 50 50 50 50 50
Power consumption [A]
0.5 1.1 2.0 2.9 0.5 1.1 2.0 2.9
24 V DC signal [mA]
15 15 15 15 15 15 15 15
Gas
Gas Natural gas LPG / Propane
Supply pressure [mbar]
20-25 37-50
Effect [kW]
14 40 70 95 14 40 70 95
Nozzle: Number of holes / Hole size [mm]
1 / 3.3 12 / 1.8 12 / 2.3 12 / 2.7 1 / 1.9 6 / 1.6 6 / 1.9 12 / 1.7
Consumption Natural gas LOW [m³/h]
1.5 3.9 6.8 9.2
Consumption Natural gas HIGH [m³/h]
1.5 3.3 5.7 7.8
Consumption LPG/Propane [kg/h]
1.1 2.9 5.0 6.8
Connection kit 410157 410156 410158
Connection type ½” internal thread ¾” external thread 6mm hose connection
Mechanics
Output [m3/h]
1,200 3,900 4,500 6,500 1,200 3,900 4,500 6,500
Distance Min.- Max. [m]
5-10 20-40 25-50 20-40 5-10 20-40 25-50 20-40
Max distance without air circulator [m]
7 30 35 30 7 30 35 30
Max distance with air circulator [m]
10 40 50 40 10 40 50 40
Net weight [kg]
13.0 26.8 38.4 13.0 26.8 38.4
Gross weight [kg]
13.0 32.1 57.0 13.0 32.1 57.0
Length [mm]
600 1200 1150 600 1200 1150
Width [mm]
406 540 580 406 540 580
Height [mm]
470 442 520 470 442 520
* Note: When using 410158 Connection kit blow heater LPG 1.5m with LPG/Propane, the supply
pressure to the regulator must be between 0.53 and 1.9 bar.