Biostatistics for Coordinators. Peter D. Christenson REI and GCRC Biostatistician. GCRC Lecture Series: Strategies for Successful Clinical Trials Session #2 June 10, 2004. Outline. Typical Flow of Data in Clinical Studies - PowerPoint PPT Presentation
Citation preview
Biostatistics for Coordinators
Peter D. Christenson
REI and GCRC Biostatistician
GCRC Lecture Series:
Strategies for Successful Clinical Trials
Session #2 June 10, 2004
Outline
• Typical Flow of Data in Clinical Studies
• Biostatistical Resources at REI and GCRC
• Statistical Components of Research Protocols
Typical Flow of Data in Clinical Studies
Reports
Spreadsheets
Statistics Software
Graphics Software
SourceDocuments
Database
CRFs
Database is the hub: export to applications
Biostatistical Resources at REI and GCRC
• Biostatistician: Peter Christenson– Assist with study design, protocol development– Minor, limited analysis of data– Major analysis as investigator with %FTE on
funded studies– GCRC and non-GCRC studies
• Biostatistics short courses: 6 weeks 2x/yr• GCRC computer laboratory in RB-3
– For GCRC studies– Statistical, graphics, database software
• Webpage: www.gcrc.humc.edu/Biostat
NCSS: Basic intuitive statistics package in GCRC computer lab; has power module
SPSS: More advanced statistics package in GCRC lab
SAS: Advanced professional statistics package in GCRC lab
Sigma Plot: Scientific publication graphics software in GCRC lab
nQuery: Professional study size / power software in GCRC lab
www.gcrc.humc.edu/Biostat
www.statsoft.com/textbook/stathome.html
Good general statistics book by a software vendor.
www.StatCrunch.com
NSF-funded software development.
Not a download; use online from web browsers
www.stat.uiowa.edu/~rlenth/PowerOnline Study Size / Power Calculator
Statistical Components of Protocols
• Target population / sample (generalizability).• Quantification of aims, hypotheses.• Case definitions, endpoints quantified. • Randomization.• Blinding.• Study size: screen, enroll, complete.• Use of data from non-completers.• Justification of study size (power, precision,
other).• Methods of analysis.• Mid-study analyses.
Randomization
• Helps assure attributability of treatment effects.
• Blocked randomization assures approximate chronologic equality of numbers of subjects in each treatment group.
• Recruiters must not have access to randomization list.
• List can be created with a random number generator in software (e.g., Excel, NCSS), printed tables in stat texts, pick slips out of a hat.
Study Size / Power : Definition
• Power is the probability of declaring a treatment effect from the limited number of study subjects, if there really is an effect of a specified magnitude (say 10) among all persons to whom we are generalizing.[ Similar to diagnostic sensitivity. ]
• Power is not the probability that an effect (say 10) observed in the study will be “significant”.
Study Size / Power : Confusion
Reviewer comment on a protocol:
“… there may not be a large enough sample to see the effect size required for a successful outcome. Power calculations indicate that the study is looking for a 65% reduction in incidence of … [disease]. Wouldn’t it also be of interest if there were only a 50% or 40% reduction, thus requiring smaller numbers and making the trial more feasible?”
Investigator response was very polite.
Study Size / Power : Issues
• Power will be different for each outcome.
• Power depends on the statistical method.
• Five factors including power are inter-related. Fixing four of these specifies the fifth:– Study size– Power– p-value cutoff (level of significance, e.g.,
0.05)– Magnitude of treatment effect to be
detected– Heterogeneity among subjects (std dev)
Study Size / Power : Example
• “The primary outcomes for the hydrocortisone trial are changes in mean MAP and vasopressor use from the 12 hours prior to initiation of randomized treatment to the 96 hours after initiation.”
• Mean changes in placebo subjects will be compared with hydrocortisone subjects using a two sample t-test.
Project #10038: Dan Kelly & Pejman Cohan
Hypopituitarism after Moderate and Severe Head Injury
Study Size / Power : Example Cont’dThe following table presents detectable differences, with p=0.05 and 80% power, for different study sizes.
Total Number
of Subjects
Detectable Difference in
Change in Mean MAP (mm Hg)(1)
Detectable Difference in
Change in Mean Number
of Vasopressors(2)
20 10.9 0.77 40 7.4 0.49 60 6.0 0.39 80 5.2 0.34
100 4.6 0.30 120 4.2 0.27
Thus, with a total of the planned 80 subjects, we are 80% sure to detect (p<0.05) group differences if treatments actually differ by at least 5.2 mm Hg in MAP
change, or by a mean 0.34 change in number of vasopressors.
Study Size / Power : Example Cont’dPilot data: SD=8.16 for ΔMAP in 36 subjects.
For p-value<0.05, power=80%, N=40/group, the detectable Δ of 5.2 in the previous table is found as:
Study Size / Power : Summary
• Power analysis assures that effects of a specified magnitude can be detected.
• For comparing means, need (pilot) data on variability of subjects for the outcome measure. [E.g., Std dev from previous study.]
• Comparing rates (%s) does not require pilot variability data. Use if no pilot data is available.
• Helps support (superiority) studies with negative conclusions.
• To prove no effect (non-inferiority), use an equivalency study design.
Non-completing Subjects
• Enrolled subjects are never “dropouts”.• Some studies may require recording last
status at last known time.• Protocol should specify:
– Primary analysis set (e.g., all subjects with at least one post-baseline value for the primary endpoint, “modified Intent-to-Treat”.)
– How final values will be assigned to non-completers (e.g., Last Value Carried Forward).
• Study size estimates should incorporate the number of expected non-completers.
Mid-Study Analyses
• Mid-study comparisons should not be made before study completion unless planned for (interim analyses). Early comparisons are unstable, and can invalidate final comparisons.
• Mid-study reassessment of study size is advised for long studies. Only standard deviations to-date are used. Often, these analyses can be performed at the time of DSM reports.