13
bintec WLAN Controller Overview

Bintec WLAN Controller Overview. Designed for the requirements of organization with up to 100 employees Suitable for installation from 2 to 24 Access

Embed Size (px)

Citation preview

Page 1: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN ControllerOverview

Page 2: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

Designed for the requirements of organization with up to 100 employees

Suitable for installation from 2 to 24 Access Points

The installation of a new Wireless network must be possible without special training of the administrator.

The Wireless network must be support seamless hand-over for VoWifi phones. The network must be “Voice Ready”.

bintec WLAN Controller Target definition

Page 3: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

The WLAN Controller requires no dedicated hardware or a server.

For up to 6 APs the WLAN Controller license is running a Master-AP

For 7-24 APs a bintec R1202 router is required a controller hardware.

The WLAN Controller infrastructure requires a DHCP server. The functionality of the DHCP server can provide by the WLAN Controller or via an external DHCP server (i.e. Microsoft Server 2008)

bintec WLAN Controller The hardware

Page 4: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN Controller Installations with up to 6 APs

SwitchDHCP Server

AP 2 AP 3 AP 6

WLAN Controller license at a

W1002n (AP1)

AP 1

Page 5: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN Controller Installations with up to 6 APs

SwitchR1202WLAN Controller +

DHCP Server

AP 2 AP 3 AP 24

WLAN Controller license for up 24 APs

at a R1202

AP 1 AP 23

Page 6: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

Support the Access Points W1002n, WIx40n, WIx65n with SW-Release 7.9.6 or higher

Simple wizard based quick installation allow the installation in only five steps.

Automatic detection and installation of new access points.

Frequency management with automatic channel management

VLAN and Multi-SSID support

Any configuration changing, i. e. the adding of a new SSID, and the setup of the new configuration to all access points requires only a few clicks and is in a few seconds done.

Configuration management, the configuration are stored central at the WLAN controller. In case of power lost the WLAN controller distribute the configuration automatically after the power up.

The monitor support the detection of Neighbor AP und the supervision of clients.

Automatic firmware rollout for all managed access points.

bintec WLAN Controller Functionality

Page 7: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN Controller WLAN setup in five steps: Step 1

Selection of the interface and definition of the DHCP Servers

Page 8: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN Controller WLAN setup in five steps: Step 2

Selection of the frequency band (2,4 or 5 GHz)

Page 9: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN Controller WLAN setup in five steps: Step 3

Definition of the SSID details …

Page 10: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN Controller WLAN setup in five steps: Step 4

The detected APs are shown.

The APs there we want to manage are selected, …. and the installation is started by pressing the START button.

Page 11: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

bintec WLAN Controller WLAN setup in five steps: Step 5

Finished !

The APs have now a channel definition and the units are managed.

Page 12: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

Functionality of the license

The WLAN Controller functionality is available at each R-Serie, W-Serie and WI-Serie with software release 7.9.6 or higher and requires a license.

Up to 6 APs are manageable from one of the Access Points (Master-AP). No dedicated hardware for the controller is required. The Master-AP required the WLAN controller licenses.

If the network contain more than 6 APs, a bintec router i.e. R1202 is required as WLAN controller.

The Slave APs requires no license, but a software release 7.9.6 or higher.

Without WLAN controller license only one AP is manageable. This enables the customer to testing the WLAN controller free of charge.

License

To keep the numbers of different part numbers small only a license for 6 Access Points is available

For the W-Series and the WI-Series only one license are possible to install to support up to 6 Access Points

For the R-Series only up to 4 license are possible to install to support up to 24 Access Points

bintec WLAN Controller License model

Page 13: Bintec WLAN Controller Overview.  Designed for the requirements of organization with up to 100 employees  Suitable for installation from 2 to 24 Access

Thank you for your attention