Page 1 of 3
BID NO.: 663 PROJECT NAME & LOCATION NYCCT New Academic Building 285 Jay Street Brooklyn, New York Description: Furnish, Deliver and Install Vertical Reciprocating Conveyor Lift Bid Open Location: DASNY 515 Broadway, Albany, New York Bid Open Date: February 26, 2020 Bid Open Time: 2:30 p.m. Contact: Susan Valente (518) 257-3363
NOTICE TO BIDDERS
MAIL BIDS EARLY Sealed bids will be received by DASNY at the above address for the items listed in the attached Bid Breakdown and Schedule. When submitting your bid you must:
1. Prepare your bid on the attached Bid Breakdown and Schedule. Return one signed original of the Bid Breakdown and Schedule
2. If your bid deviates from Specifications, explain such deviations or qualifications on your letterhead, setting forth therein such explanations, and attach them to the Bid Breakdown and Schedule.
3. Submission of a bid constitutes full knowledge and acceptance of all provisions of the Notice to Bidders, all information referenced in the Purchasing General Conditions, Supplemental and Detailed Specifications, the Bid Submission and any Supplemental General Requirements contained herein, as well as any addenda issued in relation to the Invitation for Bids.
4. Each bid shall bear on the outside of the envelope the name of the bidder, address, telephone number and designated as a bid for the following: DASNY Bid No. 663 - Furnish, deliver and install a vertical reciprocating conveyor lift. Bid Opening Date: February 26, 2020 @ 2:30PM Return to: DASNY Attn: Purchasing Unit 515 Broadway Albany, NY 12207-2964
Page 2 of 3
Bid No.: 663
When a sealed bid is placed inside another delivery jacket, the bid delivery jacket must be clearly marked on the outside “BID ENCLOSED” and “ATTENTION: PURCHASING UNIT”. The Dormitory Authority will not be responsible for receipt of bids which do not comply with these instructions.
5. Mail bid responses early in order for them to be received before the time of
the bid opening. Late bids will be automatically rejected. Individuals submitting bids in person or by private delivery services should allow sufficient time for processing through building security to assure that the bids are received prior to the deadline for submitting bids. All individuals who plan to attend bid openings will be required to present government-issued picture identification to building security officials and obtain a visitor’s pass prior to attending the bid opening.
6. In accordance with State Finance Law § 139-j and 139-k, this solicitation includes and imposes certain restrictions on communications between Dormitory Authority personnel and an Offerer during this procurement process. Designated contact for this solicitation is: Susa Valente, Purchasing Coordinator, Dormitory Authority – State of New York, 515 Broadway, Albany, NY 12207, (518) 257-3363. Contacts made to other Dormitory Authority Personnel regarding this procurement may disqualify the Offerer and affect future procurements with governmental entities in the State of New York. Please refer to the Authority’s website www.dasny.org for Authority policy and procedures regarding this law, or the NYS office of General Services website www.ogs.ny.gov/BU/PC/ for more information about this law.
Page 3 of 3
Bid No.: 663
If you are not submitting a bid it is requested that you complete and return the lower portion of this form
(Please check all that apply and provide comments in the space provided, if necessary)
We are not Submitting a bid.
We Request removal of our name from the mailing list.
Location of the job site. Commodity is not carried by our company.
Scope is too large.
Other/Additional Explanation:
NAME OF BIDDER:
ADDRESS:
Street City State Zip Telephone
Signature of Bidder Official Title
Rev. 12/12
CLAUSES PURSUANT TO THE OMNIBUS PROCUREMENT ACT OF 1992
It is the policy of New York State to maximize opportunities for the participation of New York State business enterprises, including minority and woman-owned business enterprises as bidders, subcontractors and suppliers on its procurement contracts.
Information on the availability of New York subcontractors and supplies is available from:
Empire State Development Small Business Division 30 South Pearl Street, 7th Floor Albany, NY 12207 Phone: (800) 782-8369
A directory of minority and woman-owned business enterprises is available from:
Empire State Development Division of Minority and Women Business Development 30 South Pearl Street Albany, NY 12207 Phone: (518) 292-5250
Online Directory: https://ny.newnycontracts.com/FrontEnd/VendorSearchPublic.asp
DASNY maintains a directory of minority and women-owned business enterprises: http://www.dasny.org/construc/mwsbereg/index.php
The contractor acknowledges notice that New York State may seek to obtain offset credits from foreign countries as a result of this contract and agrees to cooperate with the State in these efforts.
DASNY encourages the use of recycled Materials in the manufacturing process. To that end, the recycled product must meet the same codes, specifications and standards the non-recycled materials do, including requirements for cost, installation, aesthetics, availability and maintenance.
Rev. 12/12
The Omnibus Procurement Act of 1992 and § 2879 of the NYS Public Authorities Law require that by signing this bid, contractors certify that whenever the total bid amount is greater than $1 million:
1. The contractor has made reasonable efforts to encourage the participation of New York State Business Enterprises as suppliers and Subcontractors on this project, and has retained the documentation of these efforts to be provided upon request to the State. If the contractor determines that NYS business enterprises are not available to participate on the contract as subcontractors or suppliers, the contractor shall provide a statement indicating the method by which such determination was made. If the contractor does not intend to use subcontractors, contractor shall provide a statement verifying such;
2. The contractor has complied with the Federal Equal Opportunity Act of 1972 (PL 92-261), as amended;
3. The contractor agrees to make reasonable efforts to provide notification to New York State residents of employment opportunities on this project through listing any such positions with the Job Service Division of the New York State Department of Labor, or providing such notification in such manner as is consistent with existing collective bargaining contracts or agreements. The contractor agrees to document these efforts and to provide said documentation to the State upon request;
DASNY is required by law to notify the NYS Department of Economic Development of any procurement contract for one million dollars or more that is to be awarded to an out-of-state vendor. This notice must be done simultaneous to the notification of award provided to the vendor. A purchase order or contract cannot be issued until fifteen (15) days after such notification is provided.
Revised 12/12
GENERAL SPECIFICATIONS
(1) The enclosed Purchasing General Conditions are hereby incorporated by reference.
Submission of a bid response shall constitute acceptance of such conditions. Any exceptions/clarifications/qualifications to these conditions or other specifications and/or requirements contained herein must be clearly stated in the bid response and, depending upon the nature of such, may be grounds for rejection of your bid.
(2) Bids must be submitted in the bidder’s full legal name, or the bidder’s full legal name plus a registered assumed name, if any.
(3) All NYS bidders are required to be registered to do business with the NYS Department of State or their local County Clerk, whichever is applicable.
(4) All out-of-state bidders will be required to provide proof of registration to do business in their state. All out-of-state bidders that “do business in New York State” MUST BE REGISTERED WITH THE NYS DEPARTMENT OF STATE. Please contact the NYS Department of State at (518) 473-2492. Information is available at the DOS website: www.dos.ny.gov
(5) DASNY is required by law to notify the Empire State Development of any procurement contract for one million dollars or more that is to be awarded to an out-of-state vendor. This notice must be done simultaneous to the notification of award provided to the vendor. A purchase order or contract cannot be issued until fifteen (15) days after such notification is provided.
(6) Empire State Development is required by law to identify states and other jurisdictions that impose preferences or other penalties against New York bidders. DASNY is precluded from soliciting bids or entering into procurement contracts with companies that have their principal place of business located in one of the listed jurisdictions, unless the procurement is for a product that is substantially manufactured in New York State or the services are to be performed in New York State. Currently, this list of jurisdictions includes the states of Alaska, Hawaii, Louisiana, South Carolina, West Virginia and Wyoming.
(7) Unless otherwise indicated, any reference to brands or model numbers is intended to establish a standard. Items of all manufacturers will be considered, provided the item is determined to meet or exceed the required specification. DASNY’s decision as to whether a substitute item meets specification will be final. Your attention is directed to Article II-7, Page 5 of the General Conditions. In order to evaluate substitute items, detailed specifications must be submitted for any product that is other than the one(s) specified in the bid.
Revised 12/12
GENERAL SPECIFICATIONS CONTINUED
(8) Unless otherwise noted, guarantee on all items is to be one year as detailed in Article XVI of the General Conditions
(9) All upholstered furniture and drapery panels and lining must meet strict flammability requirements. Standards applicable to this bid, if any, will be delineated in the Detailed Specifications.
(10) LABOR/TRADES - Any labor, materials or means whose employment, or utilization during the course of this contract, shall not in any way cause or result in strike, work stoppages, delays, suspension of work; or similar troubles by workers employed by this contractor or his subcontractors, or by any of the trades working in or about the buildings and premises where work is being performed. Any violation by the contractor of this requirement may in the sole judgment of DASNY be considered as proper and sufficient cause for declaring the contractor to be in default, and for the owner to take action against him as set forth in the Purchasing General Conditions, Article VIII, “Termination", or such other action as DASNY may deem proper.
(11) Bid results are available on the DASNY website (www.DASNY.org). Bid results will not be given over the phone.
(12) If you are a NYS Certified Minority or Women Owned Business, please include a copy of your certification with the bid.
ANDREW M. CUOMO ALFONSO L. CARNEY, JR. REUBEN R. MCDANIEL, III Governor Chair Acting President & CEO
ALBANY (HEADQUARTERS): 515 Broadway, Albany, NY 12207 | 518-257-3000
NEW YORK CITY: One Penn Plaza, 52nd Floor, New York, NY 10119 | 212-273-5000
BUFFALO: 539 Franklin Street, Buffalo, NY 14202 | 716-884-9780
ROCHESTER: 3495 Winton Place, Building C, Suite 1, Rochester, NY 14623 | 585-450-8400
DORMITORY AUTHORITY STATE OF NEW YORK
WE FINANCE, DESIGN & BUILD NEW YORK’S FUTURE.
www.dasny.org
SUPPLEMENTAL SPECIFICATIONS
The following items are attached for informational purposes. Referenced documents need not be returned with the proposal. These documents are only applicable to the successful bidder and the ensuing procurement contract. Documents are only applicable to the successful bidder and the ensuing procurement contract. Documents applicable to the procurement that will result from this Invitation for Bids are designated by a check box ( ). Unless otherwise indicated, the referenced documents are located at the end of this Invitation for Bids.
Purchasing General Conditions – The DASNY Purchasing General Conditions contains terms and conditions of purchases made by DASNY. It is recommended that this document be reviewed fully.
M/WBE Utilization Plan and Request for Waiver - Minority and Women-Owned Business Enterprise (M/WBE) goals for this project are 0% and 0%, respectively. The successful bidder shall be required to complete a Utilization Plan or Request for Waiver, to be approved by DASNY’s Opportunity Programs Group. Reference Purchasing General Conditions, Article XIX, Affirmative Action for Contracts Mr. Michael Clay, DASNY Opportunity Programs Group at (518) 257-3464, is available to assist all bidders in attaining these goals. Reference the enclosed “Good Faith Efforts Guidelines”.
Supplemental General Requirements – Attached (if applicable) are the Supplemental General Requirements (SGRs) which provide important logistical information and additional conditions which govern this procurement. Please read these SGRs carefully.
Form of DASNY Contract – The procurement resulting from the Invitation for Bids will be executed through a DASNY purchase order and a related contract. The contract executed with the successful bidder will be in the same substantial form as the attached “Form of Contract”. Note that this Invitation for Bids and any response to such will be annexed as binding terms of the purchase agreement.
Certificate of Insurance (sample enclosed) – The successful bidder will be required to provide a Certificate of Insurance pursuant to Article XIV of the enclosed Purchasing General Conditions. The certificate shall name DASNY and other designated parties as additional insureds.
Page 2
SUPPLEMENTAL SPECIFICATIONS CONTINUED
Worker’s Compensation / Disability Insurance – The successful proposer will be required to provide specific documentation with respect to Worker’s Compensation and Disability Insurance pursuant to Article XIV of the enclosed Purchasing General Conditions. Requirements are detailed in the enclosed “Workers’ Compensation and Disability Benefits Requirements” document.
Prevailing Wage Schedule – NYS Labor Law requires all wages paid by contractors and subcontractors on public work projects be paid at the prevailing wage rates. Enclosed is the current rate schedule for the appropriate county. Contractors and Subcontractors are responsible for obtaining current rates throughout the course of the project. The NYS Department of Labor (NYS DOL) updates these rates on July1st of each year. Current rates can be obtained on the NYS DOL website (www.labor.state.ny.us) or by fax at (518) 485-1870. Note that an executed Contractor and Subcontractor Certification and certified payrolls, which include the hours and days worked by each workman, laborer or mechanic, the occupation at which he worked, the hourly wage rate paid and the supplements paid or provided, must be submitted with each and every payment requisition. DASNY will not process an invoice without this information. Forms are available on the DASNY website: http://www.dasny.org/construc/forms2/vendors.php
Labor and Material Payment Bond – The successful bidder must be prepared to provide surety bonds prior to award in accordance with Article XIV of the DASNY Purchasing General Conditions. The costs of these bonds are to be separately stated in the total bid price as indicated on the Bid Breakdown and Schedule.
Performance Bond – The Successful bidder must be prepared to provide surety bonds prior to award in accordance with Article XIV of DASNY Purchasing General Conditions. The costs of these bonds are to be separately stated in the total bid price as indicated on the Bid Breakdown and Schedule.
Standard Vendor Responsibility Questionaire (SVRQ) – The successful proposer, in accordance with Article XXII of DASNY Purchasing General Conditions, will be required to complete the enclosed SVRQ. The award of a contract will be subject to a review of the information contained in these forms.
Page 3
SUPPLEMENTAL SPECIFICATIONS CONTINUED
NYS Uniform Contracting Questionaire (UCQ) – The successful proposer will be required to complete the enclosed UCQ. The award of a contract will be subject to a review of the information contained in these forms.
DASNY Contractor and Consultant Questionaire (CCQ) – The successful proposer will be required to complete the enclosed CCQ. The award of a contract will be subject to a review of the information contained in these
ANDREW M. CUOMO ALFONSO L. CARNEY, JR. REUBEN R. MCDANIEL, III Governor Chair Acting President & CEO
ALBANY (HEADQUARTERS): 515 Broadway, Albany, NY 12207 | 518-257-3000
NEW YORK CITY: One Penn Plaza, 52nd Floor, New York, NY 10119 | 212-273-5000
BUFFALO: 539 Franklin Street, Buffalo, NY 14202 | 716-884-9780
ROCHESTER: 3495 Winton Place, Building C, Suite 1, Rochester, NY 14623 | 585-461-8400
DORMITORY AUTHORITY STATE OF NEW YORK
WE FINANCE, DESIGN & BUILD NEW YORK’S FUTURE.
www.dasny.org
Supplemental General Requirements
Site Visit: Site Visit February 12, 2020 at 9:00 a.m. Meet at the Lobby of 285 Jay Street in Brooklyn, N.Y. Contact Person: Juan Manuel Alvarez Telephone No.: 347-844-1538
Requests for Information:
All questions pertaining to Bid No. 663 – Furnish, deliver and install vertical reciprocating conveyor lift are due no later than 4:00 p.m. on February 14, 2020 to [email protected]. RFI Responses will be posted via Addenda to DASNY’s Website in the Attachments Section of the Bid Opportunity Page for Bid No. 663.
Prevailing Wage:
The install portion of this bid is pursuant to Article 8 of the New York State Labor Law. The wages paid for a legal day’s work shall not be less than the prevailing rate of wages and defined by New York State Labor Law. Each laborer, worker or mechanic employed by the Professional, the Professional’s Subconsultant, or any other person doing or contracting to do the whole or any part of the Work contemplated by the Contract shall be paid not less than the prevailing rate of wages as defined by New York State Labor Law and shall be provided not less than supplements as required by New York State Labor Law. The Prevailing Rate Case (PRC) number for the services pursuant to the prevailing rate of wages assigned to this bid is 2019001388.
ANDREW M. CUOMO ALFONSO L. CARNEY, JR. GERRARD P. BUSHELL Governor Chair President
CORPORATE HEADQUARTERS
515 Broadway Albany, New York 12207-2964
T 518-257-3000 F 518-257-3100
NEW YORK OFFICE
One Penn Plaza, 52nd Floor New York, New York 10119-0098
T 212-273-5000 F 212-273-5121
BUFFALO OFFICE
539 Franklin Street Buffalo, New York 14202-1109
T 716-884-9780 F 716-884-9787
www.dasny.org
DETAILED SPECIFICATIONS
SCOPE OF EQUIPMENT: A. Product Data: Provide rated capacity, dimensions, performance, operation, safety features, controls, and finishes. B. Shop Drawings: Provide plans, elevations, sections, details, and attachments to other work. Indicate loading on structure and required clearances.
1. Shop drawing, including plan and elevation dimensions of openings for chain closures, track mounting configuration and part list for specified product.
C. Certificates and Permits: Provide inspection and acceptance certificates and operating permits, as required by authorities having jurisdiction, for normal, unrestricted use of lifts. D. Maintenance Data: Provide maintenance manuals. Include parts list with sources indicated and recommended parts inventory list. E. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair, restore, or replace defective work within specified warranty period.
1. Warranty Period: 12 months from date of Substantial Completion. REQUIREMENTS: MATERIALS: A. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M. B. Steel Tubing: ASTM A 500. C. Steel Pipe: ASTM A 53/A 53M; standard weight (Schedule 40), unless otherwise indicated or required by structural loads. D. Carbon-Steel Sheet: Either cold-rolled steel sheet, ASTM A 366/A 366M, or hot-rolled steel sheet, ASTM A 569/A 569M. E. Galvanized Steel Sheet: ASTM A 653/A 653M, G90 (Z275) zinc coating. F. Stainless-Steel Bars and Shapes: ASTM A 276, Type 304.
ANDREW M. CUOMO ALFONSO L. CARNEY, JR. GERRARD P. BUSHELL Governor Chair President
CORPORATE HEADQUARTERS
515 Broadway Albany, New York 12207-2964
T 518-257-3000 F 518-257-3100
NEW YORK OFFICE
One Penn Plaza, 52nd Floor New York, New York 10119-0098
T 212-273-5000 F 212-273-5121
BUFFALO OFFICE
539 Franklin Street Buffalo, New York 14202-1109
T 716-884-9780 F 716-884-9787
www.dasny.org
G. Stainless-Steel Tubing: ASTM A 554, Grade MT-304. H. Stainless-Steel Sheet, Strip, Plate, and Flat Bar: ASTM A 666, Type 304. I. Inserts: Furnish required concrete and masonry inserts and similar anchorage devices for installing structural members, guide rails, machines, and other lift components where installation of devices is specified in another Section. J. Expansion Anchors: Anchor-bolt-and-sleeve assembly of material indicated below with capability to sustain, without failure, a load equal to 10 times the load imposed as determined by testing per ASTM E 488 conducted by a qualified independent testing agency:
1. Material: Carbon-steel components, zinc plated to comply with ASTM B 633, Class Fe/Zn 5.
K. Nonshrink, Nonmetallic Grout: Factory-packaged, nonstaining, noncorrosive, nongaseous grout complying with ASTM C 1107. L. Hydraulic Fluid: Nontoxic, readily biodegradable, fire-resistant fluid made from vegetable oil with antioxidant, anticorrosive, antifoaming, and metal-passivating additives. Hydraulic fluid is approved by elevator manufacturer for use with elevator equipment.
1. Product: Subject to compliance with requirements, provide "Hydro Safe" by Hydro Safe Oil Division, Inc.
VERTICAL PLATFORM LIFTS A. Vertical Reciprocating Conveyor Lift Basis-of-Design: Pflow Industries, Inc. Series m-t VRC, (telephone
414-352-9000) or an equivalent product from one of the following manufacturers:
1. Advance Lifts, Inc. 2. Giant Lift Equipment Mfg. Co. Inc. 3. Lift-Avator, Inc.
B. Lift:
1. Platform Size: 96 by 120 inches (2 440 by 3 050 mm). 2. Capacity: 4000 pounds. 3. Rated Speed: 25 fpm (0.15 m/s). 4. Motor: 5 HP.
C. Power Supply: 460 V, 60 Hz, 3 phase. D. Control System: Provide push-button-operated control.
1. System Control Voltage: 24-V ac.
ANDREW M. CUOMO ALFONSO L. CARNEY, JR. GERRARD P. BUSHELL Governor Chair President
CORPORATE HEADQUARTERS
515 Broadway Albany, New York 12207-2964
T 518-257-3000 F 518-257-3100
NEW YORK OFFICE
One Penn Plaza, 52nd Floor New York, New York 10119-0098
T 212-273-5000 F 212-273-5121
BUFFALO OFFICE
539 Franklin Street Buffalo, New York 14202-1109
T 716-884-9780 F 716-884-9787
www.dasny.org
E. Concealed Wiring: Enclose wiring within housings of units. Do not use conduit exposed to view. F. Self-Supporting Units: Support vertical loads of units only at base, with lateral support only at landing levels. G. Runway Enclosure: Manufacturer's standard rectangular steel-tube frame with expanded steel sheet panels.
1. Platform Gates: Rectangular steel-tube frames with expanded steel-sheet panels. 2. Gate Hardware: Provide electrical interlocks at gates at each landing.
H. Platform: 0.123-inch- (3.1-mm-) thick, diamond plate steel deck. I. Carriage Gates: Provide gates at each end of platform, expanded steel sheet, with a minimum opening height of 80 inches. J. Safety Override for Over-Capacity Operation: Provide a device to stop and hold conveyor lift when the lift is loaded to its capacity or beyond. This override device must operate independently of the driving mechanism. FINISHES A. General: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. B. Steel and Iron Finishes: Prepare and finish iron and steel, including galvanized steel, as follows:
1. Prepare uncoated ferrous-metal surfaces to comply with SSPC-SP 3, "Power Tool Cleaning," or SSPC-SP 6/NACE No. 3, "Commercial Blast Cleaning," followed by a conversion coating of type suited to organic coating applied over it.
2. Powder-Coated Finish: Immediately after cleaning and pretreating, apply manufacturer's standard, thermosetting polyester or acrylic urethane powder coating with a cured film thickness not less than 1.5 mils (0.04 mm).
a. Color and Gloss: As selected by Architect from manufacturer's full range.
SCOPE OF WORK: INSTALLATION A. General: Comply with manufacturer's written installation instructions applicable to products and applications indicated, except where more stringent requirements apply.
ANDREW M. CUOMO ALFONSO L. CARNEY, JR. GERRARD P. BUSHELL Governor Chair President
CORPORATE HEADQUARTERS
515 Broadway Albany, New York 12207-2964
T 518-257-3000 F 518-257-3100
NEW YORK OFFICE
One Penn Plaza, 52nd Floor New York, New York 10119-0098
T 212-273-5000 F 212-273-5121
BUFFALO OFFICE
539 Franklin Street Buffalo, New York 14202-1109
T 716-884-9780 F 716-884-9787
www.dasny.org
1. Enclose wiring within housings of units or building construction. Do not use conduit exposed to view in finished spaces.
B. Alignment: Coordinate runway gates with platform travel and positioning, for accurate alignment and minimum clearance between platforms, runway gates, sills, and gate frames. C. Position sills accurately, raised slightly above adjoining floor surfaces to minimize intrusion of dirt and spillage into runway. Fill space under sills solidly with nonshrink, nonmetallic grout. D. Adjust stops for accurate leveling at each landing, within specified tolerances.
1. Leveling Tolerance: 1/4 inch (6 mm) up or down, regardless of load and direction of travel. E. Lubricate operating parts of lift, including drive mechanism, guide rails, gates, safety devices, and hardware. FIELD QUALITY CONTROL A. Acceptance Testing: On completion of lift installation and before permitting use of lifts, perform acceptance tests as required and recommended by ASME A18.1 and governing regulations and agencies. B. Operating Test: In addition to above testing, load lifts to rated capacity and operate continuously for 30 minutes between lowest and highest landings served. Readjust stops and other devices and signal equipment for accurate landings and operation of system. C. Advise Owner, Architect, and authorities having jurisdiction in advance of dates and times tests are to be performed on lifts. DEMONSTRATION A. Instruct Owner's personnel in proper use, operation, and daily maintenance of lifts. Review emergency provisions, including emergency access and procedures to be followed at time of operational failure and other building emergencies. Train Owner's personnel in procedures to follow in identifying sources of operational failures or malfunctions. Confer with Owner on requirements for a complete lift maintenance program. B. Make a final check of each lift operation with Owner's personnel present and before date of Substantial Completion. Determine that operation systems and devices are functioning properly.
CCD1 (62086) Page 1 of 6
CCD1: Construction Code Determination Form pAGE2
5 Description of Request (utilize page 3/Section 7 if additional space is needed to property descnbe this request)
This is a request for:
Interpretation or clarification
lxl Variation of Building Code or Rules per § 28-103. 3 (please state in detail the practical difficulty that is specific to this project,and provide the analysis as to equally safe alternative, as per NYC Charter Section 645(b)(2))
Variation of Multiple Dwelling Law (MDL) § 277. 16 for Article 7B Buildings (please state in detail the practical difficulty that isspecific to this project and provide the analysis as to equally safe alternative, as per NYC Charter Section 645(b)(2))
NOTE: Variations of any other MDL provisions must be filed with the Board of Standards and Appeals (BSA) per MDL § 310.
Please itemize all attachments, including plans/sketches, submitted with this form. (attachment may not be larger than 11" x 17")If request is based on a plan examiner objection, type in the applicable objection text exactly as it appears on the Objection sheet andinclude a copy of the Objection sheet in the submitted Pdf.
This project is a City University of New York (CUNY), New York Institute of Technology New Academic Buildingconsisting of classrooms and a theatre.We are seeking relief of the conveyor and carriage enclosure due to the lift being of a theatrical application, wherethe College needs to be able to receive and load large scenery which they can't do with a fully enclosed carriage.The vertical reciprocating conveyor (VRC) proposed for College is for the theater loading area and travel is from thestreet level to the first floor only.
1. Appendix K, Chapter K2, Section 6.21. 1 Safety Considerations, item (e): Conveyor(s) shall be enclosed in a 2-hour fire rated hoistway, equipped with a minimum 1%hour fire-rated entrance at each landing served.
a. For Citytech, the VRC is serving as a theater loading dock leveler. The VRC does not penetrate any slabs andis located at the Edge of slab for material and equipment delivery to the theater.
b. This application is a lift from the street level to the first floor only, approx. 7'-2" travel distan at the loading dock.c. This VRC is not used for hazards, only scenery and equipment for the College's theater.d. Access to landings is restricted to authorized College personnel with No public access.
-We respectfully request a waiver for the VRC to be in a 2-hr rated enclosure and a 1-1/2hr rated entrance at thelanding.
continued on next page
NOTE: Department of Buildings Determination will be issued on the CCD1 Response Form
6 Statements and Signature Required for all requests (If Attorney, include'Esquire'or'Esq. 'in signature)
Name (please print)I hereby state that all of the above information is correct and complete to the best ofmy knowledge. Falsification of any statement is a misdemeanor and is punishable Joseph Aliottaby a fine or imprisonment, or both. It is unlawful to give to a City employee, or for aCity employee to accept, any benefit, monetary or otheranse, either as a gratuity for Signatureproperly performing the job or in exchange for special consideration. Violation ispunishable by imprisonment or fine, or both.
*
J-'.
^L/ ̂ ^c^^J-^/n:7/><
Date
r0^ '<^ 10/16/2017 -A
\J >.<>.
'<?.^o i63't<a
-^'0^
P.E. / R.A. Seal (a Qi? ffife nd date over seal -not required for Attorney d applications)
ADMINISTRATIVE USE ONLY
Reviewed By:
Control #:
Date:
01/18
CCD1 (62086) Page 2 of 6
CCD1: Construction Code Determination Form
7 Description of Request (use this section if additional space is required for description)
PAGE 3
2. Appendix K, Chapter K2, Section 6.21.2 Guarding items (c) and (d)... the carriers shall be provided with a conveyorenclosure securely fastened to the conveyor platform.
a. The VRC lift location access is protected by full, solid roll up doors of the main building.b. The carrier has a metal guardrail and metal gate for safety.d. This application is a lift from the street level to the first floor only, approx. 7'-2" travel distance at the loading dock.e. The VRC does not penetrate any slabs and is located at the Edge of slab for material and equipment delivery to
the theater.f. This VRC is not used for hazards, only scenery and equipment for the College's theater.g. Access to landings is restricted to authorized College personnel with No public access.
-We respectfully request a waiver for the VRC to be in a fully enclosed carriage as this would prohibit the use to receiveand deliver large scenery for theatrical functions.
The safety alternative is:1. In the down position at street level there is a 7'-0" vertical acting gate and 7'-0" rated wall surrounds.2. In the up position at the first floor; we have an 7'-0" high expanded metal enclosure and double swing gate forprotection.
NOTE: Department of Buildings Determination will be issued on the CCD1 Response Form
8 Statements and Signature Required for all requests
I hereby state that all of the above information is correct and complete to the best ofmy knowledge. Falsification of any statement is a misdemeanor and is punishableby a fine or imprisonment, or both. It is unlawful to give to a City employee, or for aCity employee to accept, any benefit, monetary or otherwise, either as a gratuity forproperly performing the job or in exchange for special consideration. Violation ispunishable by imprisonment or fine, or both.
(If Attorney, include 'Esquire'or 'Esq. 'in signature)
Name (please print)
Joseph AliottaSignal
ADate
10/16/201
^A. " 'v~7^.
P.E. / R.A. S6qf .feflp ' signal date over seal -
not required for' 6n§eJQ(^ t^S^' lications)
ADMINISTRATIVE USE ONLY
Reviewed By:
Control #:
Date:
01/18
CCD1 (62086) Page 3 of 6
CCD1 (62086) Page 4 of 6
1'-6"
17'-2"10"
R78'-5"
221'-4"
13'-0" 9'-0" 15'-0"3'-6"
20'-0
"12
'-0"
30'-0
"30
'-0"
12'-0
"
317'-
4"
18'-0" 16'-7" 21'-6" 19'-1" 19'-8" 12'-7" 21'-9"36'-0"
15'-1
0"
11'-8
"7'-
9"11
'-9"
22'-9
"14
'-0"
20'-6
"6'-
0"10
'-0"
1'-8"
1'-8"
30'-0
"
3'-0"
12'-2
"3'-
0"
1'-8"
1'-9"
1'-2"
1'-3"
10°11°
12°
11'-0"
15°
16°
9°
ROW
J
STAIR JSTAIR K
STAIR L
UP
(OPEN)
RAMP
UP
PE 5 PE 6
ELEVATOR C
PE 1 PE 2 PE 3 PE 4
ELEVATOR B
SE 9ELEVATOR D
13'-4
1/2"
5'-0" 6'-038"
6'-8"15'-1" SLAB OPENING
13'-8
3/4"
1'-0 3
/4"
4"56
'-0"
7 EQ.
@ 8'
-0"
100' 0"
2"
8'-0"
7'-0" CLR.
2'-0"
MIN.
WP
R52'-2"R69'-1"
R47'-3"
31'-138"
1'-2"
3'-5"
9'-5"
9'-5"
WP
5'-3 3/8"5'-11 3/4"
2'-0"
MIN.
8'-0"
4'-6"
4'-10
"
33'-6"3'-2"
35'-0"1'-10"
7'-91 4"
48'-278"56'-73
8"
2'-0"
5 8"
7'-1" 9'-6" 15'-2"
5'-11
"20
'-51 4"
1'-10
3 4"1'-
0" 3'-6"
8'-63 4"
3'-0"
1'-8"
3'-6"
12'-2
"3'-
0"1'-
10"
3'-0"
3" 1'-6"
5'-6"
14'-6
"
5'-834"3" 4'-9"
19'-1
01 4"11
'-71 2"
4'-31 2"
6"21'-1178"
7'-7"3'-4"M.O.
22'-7"3'-4"13'-5"4"
6'-1014"
6'-734"
LOW WALL7'-0"10'-0"
1'-058"
1'-3"
1'-10
3 4"6'-
4"11
3 4"
2'-3"
6'-0"
1'-01 2"
1'-6"
10'-0
" M.O
.4'-
101 2"
3'-4"
M.O.
65'-1
1"
1'-10"
86'-7
5 8"
4'-10
1 2"3'-
4"M.
O.7'-
8"7'-
8"3'-
4"M.
O.1'-
61 2"53
'-8" M
.O.
6'-8"LOW WALL7'-0"
2'-53 8"10
"
6'-1"
2'-23 8"
5'-11"
10'-7
"7'-
115 8"
95'-1
13 8"
2'-63 4"
2'-11
1 4"
14'-934"
8'-114" 6'-81
2"
10'-6
3 4"1'-
43 4"
812"
6"15'-614"
812"
15'-10 34 "
13'-834"
4'-51 2"
4'-3"
4'-0"
4'-1 58"
8'-514"
R29'-4
"
15'-103 4"
13'-834"
4'-51 2"
4'-3" 4'-0"8'-51
4"
78'-7
5 8"
1'-71 4"
6'-73 4"
35°
6'-7 34 "
35°
2'-81 4"
6'-95 8"
6'-4"
7'-91 4"
4'-11
5 8"
29'-8 38 "6'-4"
13'-6"
7'-21 8"
4'-212"3'-0"23'-03
8"
3'-0"12'-5"
104'-
111 4"
10'-2
"
1'-0"
13'-0"
13'-9
"
1'-8" 2'-534"
3'-0" 1'-6" 3'-0" 5'-134"
7'-77 8"
6'-1"
15'-1018"
5'-0"95
8"
4'-6" 13'-1134"
2"
15'-9"
14'-3"
1'-6"
5'-0"
1'-0"1'-
0"
5'-0" 1'-6"
1'-6"
FEC-01
FEC-01
FEC-03
FEC-01
FEC-01
FEC-01
FEC-01
FEC-01
FEC-01
1'-0"1'-0"
1'-0"1'-0"
10" 10"
10"
10"
1'-0"
ADA
ADA
ADA
34'-0" 1'-0" 1'-3"1'-0"
11'-0
"1'-
0"1'-
0"
4'-4"
5'-0"
8'-418" 10'-7" 3'-67
8" 6'-6" 10"5'-1"
5'-4"
5'-9"
5'-5"
103 4"
11" 2'-618" 3'-10"
2"
2'-078" 3'-8"
10"
9'-618"
8"1'-
1"4'-
6"5'-
4"9"
5'-578" 9" 3'-10"
1'-0"
9" 9"3'-6" 1'-1" 13'-8" 1"
91 4"1'-
1"9'-
10"
9"1'-
0"
1'-11" 12'-512" 3'-6"
412"10"
4'-334" 9"
1012"10"
3'-612" 1'-01
2" 7'-112" 8'-9"
OH-03
SECURITY
34567888874
8
8
8
7
7
141514
1516
181718192019
20
3431
28
27
26
13 17
3
4
5
6
7
8
8887
4
BOX 1024
BOX 1044
BOX 1034
BOX 1014
7 7 8 8
8
ROW
A
ROW
B
ROW
C
ROW
D
ROW
E
ROW
F
ROW
G
ROW
H
ROW
O
ROW
K
ROW
L
ROW
M
ROW
N
ROW
A
ROW
B
ROW
C
ROW
D
ROW
E
UP
DN
CORRIDOR
VESTIBULE
CORRIDOR
VESTIBULE
GYM / AUDITORIUM LOBBY
GARDEN
30' WIDE PERMANENTSEWER EASEMENT
OPEN TOBELOW
LINE OFCANOPYABOVE
SEELANDSCAPEDRAWING
OPTICALSECURITYDEVICE
SLIDING INSULATEDALUM. WALLASSEMBLY
(SEE LANDSCAPE DWGS)
STAINLESS STEEL GUARDRAIL;SEE LANDSCAPE DWG.
CORRIDOR
BIKE RACKSTORAGE UNDERGARDEN; SEELANDSCAPE DWGs.
GLASS CANOPYABOVE
STRUCTURALBEAM ABOVE.SEE S-121.
PLANTER
SST WALKOFF GRATEBELOW
MILLWORKSEE A-862
VRC. RE: A-619
DN
DOORACTIVATIONBOLLARD
FLOOR DRAINW/ GRATING
FLOOR DRAINW/ GRATING
BIKE STORAGE
SS SAFETY PIPE RAIL.SEE A-871
FLOOR GRILLE- SEE 1/A-622
SLIDING DOOR.SEE 6/A-617.
RETURNAIR GRILLE
RETURNAIR GRILLE
CUSTOM STAGEPLATFORM - SEETE-111.DWG
WASTE/ RECYCL. (NIC)
INVERTED "U" RACK
FLOOR DRAINW/ GRATING
FLAGPOLE;SEE CIVILDWGs FORFOUNDATIONDEETAILS
LINE OF OVERHANGABOVE
L50BL50L50A
L50BL50 L50A
L50BL50 L50A
L50B
L50L50A
DOOR ACTIVATIONPLATE
WASTE/RECYCL.(NIC)
MOTORIZEDBLACKOUTCURTAIN, TYP.
MOTORIZEDBLACKOUTCURTAIN, TYP.
LIGHT FIXTURES;SEE ELEC. DWGs. TYP.ALSO REFER TO CIVIL DWGs FOR
EXISTING BUS STOP
EXIST. CON EDVAULT TO REMAIN
EXIST. CON EDVAULT TO REMAIN
EXIST. CON EDVAULT TO REMAIN
FE-01 BELOW
EXPOSED STRUCTURALBRACING W/ INTUMESCENTPAINT. TYP. @GYM/ATRIUM LOBBY.
FD FD
FD
FD
FD
FD
FD
FD
FDFD
FD
FDFD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FDFD
SEE 4/A-333 FORWALL TYPE 3 & 4APARTIAL PLAN
SEE 3/A-332 FOR WALLTYPE 2 PARTIAL PLAN
UP
DNDN
UP
DN
UP UP
UP
UPDN TO C1
FIXED 4'-1"STOR. REQ.
FIXED
4'-1"STOR. REQ.
FIXED5'-1"
STOR. REQ.
MOTORIZED BLACKOUT CURTAIN, TYP.
WASTE /RECYCLING (NIC)
NEW CONC. CURB &
(40)205
232232
240
240
232
232232
603
603
603
232
500
WALK-OFF MATS
WALK-OFF MATS
FLOOR GRILLE- SEE 2/A-622
GLASS PANEL RAIL .SEE A-620 FOR DETAILS.
GLASS PANEL RAIL.SEE A-620 FOR DETAILS.
GLASS PANEL RAIL.SEE A-620 FOR DETAILS.
2'-6"
CLR
.
4" CONC. PAD
EXPOSED STRUCTURALBRACING W/ INTUMESCENTPAINT @ TOILET 107.06
STRUCTURAL BRACING W/SPAYED-ON FIREPROOFING @AV.IT/SEC 107.07
EXPOSED STRUCTURALTUBE POSTS W/INTUMESCENT PAINT, TYP.
6"
-3'-3"-2'-11"
-2'-7"-2'-3"-1'-11"-1'-7"-1'-3"-0'-11"-0'-7"-0'-3"
+0'-1"
+1'-0"+1'-6"+2'-0"
+2'-6"+3'-0"
+0'-0"
+0'-0"
+0'-2"
+0'-7"
5'-534"
4'-8"
5'-0"
5'-0"
2'-10" HIGH 114" Ø
PAINTED MTL.HAND RAIL
2'-10" HIGH 114" Ø
PAINTED MTL.HAND RAIL
MATCHLINE A
MATCHLINE B
CUSTOM STAGEPLATFORM - SEETE-111.DWG
BUILDOUT ZONE, TYP.SEE TE-111.DWG.
2'-91 4"
2HR RATEDACCESS DOOR.MECH.CONTRACTOR TOPROVIDE &COORDINATE.
10'-5
1 8"
2'-7"
3'-912"
3'-912"
1'-3"
GUTTERDRAINAGEPIPING
2'-7"
1'-3"
GUTTERDRAINAGEPIPING
GUTTERDRAINAGEPIPING
2'-8516"
4'-0"
4'-0"
9"
FREE STANDINGF.A. PULL MOUNTEDON 4"X4" ALUM. TUBE
FREE STANDINGF.A. PULL MOUNTEDON 4"X4" ALUM. TUBE
9"
3"6'-
3"
2" STUDSWITH 1
2" GWBBRACED TOSTRUCTURE,6" ABOVECEILING
1'-3"
1'-3"
6'-3"
3"
9"5"
FIRECONTROLPANEL
SPRINKLERDELUGEPANEL
3'-0"2'-2"
11'-9
3 4"
10'-10"2'-034"
4" CONC. EQUIPMENTPAD/CURB.SEE ELEC. & STRUCT. DWGs,TYP.
GWB BOX-OUT ATBEAM ABOVE
GWB BOX-OUT ATBEAM ABOVE
1'-0"
2'-10" HIGH 114" Ø PAINTED
MTL. HAND RAIL ANCHOREDTO SLAB, SPACE POSTMAX. 4'-0" O.C.
2'-10" HIGH 114" Ø
PAINTED MTL.HAND RAIL.ANCHORED TOSLAB.
BOLLARDS
1'-4" SIM.
2"
2"
1'-212"
4'-0"
6"
4'-0"
6"
3'-0"
14'-0
"EQ
.EQ
.5
EQ. S
PACE
D BI
KE B
OLLA
RDS
(5) 4-1/2" DIA DOMEDSTAINLESS STEELBOLLARD CYCLOOP W/SSTL BASE COVER; 2LOOP MODEL LOCATED3'-6" O.C.; BY COLUMIBIACASCADE 2172-E-S OREQUIVALENT:
6"
7'-3"1'-4"
STAINLESS STEEL BASE COVER
NOTE: 4,000 PSI CONCRETEFOOTING AND NO. 4 REBARTHRU POST.
SEE
CIVI
L
BOLLARD ASSEMBLY WITH TWO LOOPS:SCHED. 40 BRUSHED STAINLESS STEEL SEAMLESSBICYCLE BOLLARD; MIN. WALL THICKNESS 7/32" .BOLLARD TO HAVE 2 LOOPS; LOOPS SHALL BE 1" I.D.SCHED. 40 SEAMLESS ST. STEEL
FINISHED GRADE(SEE CIVIL)
COURSE AGGRAGATE,TYPE 1, GRADE B
3'-0"
6"
STABLE, COMPACTEDSUBGRADE
1'-0"
2'-11
1/4"
11-13/16"
LEVEL 01ENLARGEDFLOOR PLANNORTH
1/8" = 1'-0"
A-107.01XSCALE:
SEAL
PROJECT TITLE:
DRAWING TITLE:
DOB No: 320375839
PAGE: OF -
DOB BSCAN STICKER
BROOKLYN, NY 11201
PROJECT TITLE:
PROJECT No: 32130.00
CITY TECH
BUILDINGACADEMIC
285 JAY STREET
KEY PLAN
NO. REVISIONDATE
CONSTRUCTION DOCUMENTS
21 Penn, Plaza, 360 31st Street, 8th Floor
BALMORI ASSOCIATES833 Washington St, 2nd FloorNew York, NY 10014 Tel: 212 431 8616
New York, NY 10001 Tel: 212 479 5400
WSP CANTOR SEINUK
JAROS BAUM & BOLLES
New York, NY 10017 Tel: 212 687 9888228 East 45th Street, 3rd Floor
New York, NY 10005 Tel: 212 530 930080 Pine Street
MEP and FP Engineers:
Landscape Designer:
Structural:
CUNY THE CITY UNIVERSITY OF NEW YORK555 West 57th Street
LANGAN
New York, NY 10019 Tel: 212 541 0468
Civil / Site:
Owner:
47 Water StreetS. Norwalk, CT 06854 Tel: 203 299 0830
Cline Bettridge Berstein
New York, NY 10010 Tel: 212 741 328030 West 22nd Street, 4th Floor
Lighting Design:
Van Deusen & Associates7 Penn Plaza, Suite 404
Shen, Milson & Wilke
Theatre Projects Consultants
New York, NY 10016 Tel: 212 725 6800417 Fifth Avenue
New York, NY 10001 Tel: 212 868 9090
Theater Consultant:
IT and Acoustical Consultant :
Vertical Transporation:
ALT Cladding Limited
141 Thomson Road, Wanchai, Hong Kong Suite 2203-2204 Tai Yip Building
Façade Consultant:
Cerami & Associates, Inc.
New York, NY 10018 Tel: 212 370 1776404 Fifth Avenue
Audiovisual Consultants:
Acoustic Dimensions
New Rochelle, NY 10801 Tel: 914 712 1300145 Huguenot Street, Suite 406
Entek Engineering, LLC
Hackensack, NJ 07601 Tel: 201 820 2801166 Ames Street
Façade Maintenance:
HM WHITE SITE ARCHITECTS107 Grand Street, 6th FloorNew York, NY 10013 Tel: 212 868 9411
Landscape Architect:
Kroll Security Group
New York, NY 10016 Tel: 212 593 1000600 Third Avenue
Security Consultant:
01/24/2013
1 03/20/2013 REVISION NO. 12 09/11/2013 REVISION NO. 153 03/12/2014 REVISION NO. 204 04/11/2014 REVISION NO. 215 05/16/2014 REVISION NO. 236 07/03/2014 BULLETIN NO. 257 07/07/2016 BULLETIN NO. 638 11/02/2016 BULLETIN NO. 689 11/13/2017 BULLETIN NO. 79
DETAIL @ BIKE BOLLARD2SCALE : 1" = 1'-0"
10 04/14/2018 POST APPROVAL AMENDMENT
10
10
320375839 ES989753506DEPT OF BLDGS Job Number Scan Code
Under Directive 2 of 1975AMENDED APPLICATION
Date:
Yong Yu
05/10/2018
Vertical Reciprocating Conveyor; Refer to A-619
CCD1 (62086) Page 5 of 6
SCALE:
SEAL
PROJECT TITLE:
DRAWING TITLE:
DOB No: 320375839
PAGE: OF -
DOB BSCAN STICKER
BROOKLYN, NY 11201
PROJECT TITLE:
PROJECT No: 32130.00
CITY TECH
BUILDINGACADEMIC
285 JAY STREET
KEY PLAN
NO. REVISIONDATE
CONSTRUCTION DOCUMENTS
21 Penn, Plaza, 360 31st Street, 8th Floor
BALMORI ASSOCIATES833 Washington St, 2nd FloorNew York, NY 10014 Tel: 212 431 8616
New York, NY 10001 Tel: 212 479 5400
WSP CANTOR SEINUK
JAROS BAUM & BOLLES
New York, NY 10017 Tel: 212 687 9888228 East 45th Street, 3rd Floor
New York, NY 10005 Tel: 212 530 930080 Pine Street
MEP and FP Engineers:
Landscape Designer:
Structural:
CUNY THE CITY UNIVERSITY OF NEW YORK555 West 57th Street
LANGAN
New York, NY 10019 Tel: 212 541 0468
Civil / Site:
Owner:
47 Water StreetS. Norwalk, CT 06854 Tel: 203 299 0830
Cline Bettridge Berstein
New York, NY 10010 Tel: 212 741 328030 West 22nd Street, 4th Floor
Lighting Design:
Van Deusen & Associates7 Penn Plaza, Suite 404
Shen, Milson & Wilke
Theatre Projects Consultants
New York, NY 10016 Tel: 212 725 6800417 Fifth Avenue
New York, NY 10001 Tel: 212 868 9090
Theater Consultant:
IT and Acoustical Consultant :
Vertical Transporation:
ALT Cladding Limited
141 Thomson Road, Wanchai, Hong Kong Suite 2203-2204 Tai Yip Building
Façade Consultant:
Cerami & Associates, Inc.
New York, NY 10018 Tel: 212 370 1776404 Fifth Avenue
Audiovisual Consultants:
Acoustic Dimensions
New Rochelle, NY 10801 Tel: 914 712 1300145 Huguenot Street, Suite 406
Entek Engineering, LLC
Hackensack, NJ 07601 Tel: 201 820 2801166 Ames Street
Façade Maintenance:
HM WHITE SITE ARCHITECTS107 Grand Street, 6th FloorNew York, NY 10013 Tel: 212 868 9411
Landscape Architect:
Kroll Security Group
New York, NY 10016 Tel: 212 593 1000600 Third Avenue
Security Consultant:
AUDITORIUMPLAN AND SECTIONDETAILS
AS NOTED
A-619.00XX
WALL SECTION THRU VRC/OVERHEAD DOOR6SCALE : 1/4" = 1'-0"
JAMB DETAIL @ AUDITORIUM ROLL-UP DOOR8SCALE : 1 1/2" = 1'-0"
DETAIL SECTION OF CURB OVER STEEL2SCALE : 1" = 1'-0"
DETAIL SECTION OF CURB OVER CONCRETE3SCALE : 1" = 1'-0"
WALL SECTION THRU PE5 & PE6 - ELEVATOR SHAFT1SCALE : 1/4" = 1'-0"
HEAD DETAIL @ AUDITORIUM ROLL-UP DOOR7SCALE : 1 1/2" = 1'-0"
CURB DETAIL4SCALE : 3" = 1'-0"
LAYOUT PLAN - VRC5SCALE : 1/4" = 1'-0"
EXHAUST DUCTWORK RUN AT MID-PT9SCALE : 1/4" = 1'-0"
EXHAUST DUCTWORK RUN AT NORTH SIDE10SCALE : 1/4" = 1'-0"
01/24/2013
1 09/11/2013 REVISION NO. 151
REV. NO. 1509/11/2013
1REV. NO. 1509/11/2013
CCD1 (62086) Page 6 of 6
BuildingsAI1: Additional Information
Must be typewritten.
Orient and affix BIS
job number label here
Page number of BIS Document No.
1 Location and Job Information Required for all applications.
House No(s) 285 Street Name Jay St
Borough Brooklyn Block Lot BIN CBNo.
2 Revisions to Plans/Drawings Required whenever updating plans. All revisions for each page must be clearly described in section 3.
Submission is part of a Post Approval Amendment (PAA)? [_] Yes PW1 required Q No Indicate all actions for this submission:Original/New/ Superseding ^^^^ Original/New/ Superseding ^.̂ Original/New/ Superseding ^;^ Original/New/ SupersedingOmit Page ID Page ID """"" Omit Page ID Page ID "u'u" Omit Page ID Page ID ~ Ht-uu" Omit Page ID Page ID
N A619.00
For "Action" use "N" for new page, "S" for superseding page, "0" for omitting page.
3 Additional Information Required for all applications.
submitting planA619.01 to show the Vertical Reciprocating Conveyor system.
Is this section continued on additional AI1 forms? Q Yes Q No
/" ^ DA^c?'
^/"'*
/^.^̂̂Falsification of any statement is a misdemeanor and is punishable by a fine or imprisonment, or both. It isunlawful to give to a city employee, or for a city employee to accept, any benefit, monetar/ or otherwise,either as a gratuity for properly performing the job or in exchange for special consideration. Violation ispunishable by imprisonment or fine or both. I understand that if I am found after hearing to have knowingly or o.negligently made a false statement or to have knowingly or negligently falsified or allowed to be falsified anycertificate, form, signed statement, application, report or certification of the correction of a violation requiredunder the provisions of this code or of a rule of any agency, I may be barred from filing further applications ordocuments with the Department.
Name (Rleas p09)JOSEPH L
^1
ture o ig3'>90^ s< 0
Date
//^, ^2.0.A. Seal ('appiy-seg/J ;... "date over seal)
3/09
320375839 ES496453299DEPT OF BLDGS Job Number Scan Code
APPROVEDUnder Directive 2 of 1975
AMENDED APPLICATION
Date:
Katia Ilieva Asst. Plan Examiner
01/22/2020
320375839 ES958022024DEPT OF BLDGS Job Number Scan Code
SCALE:
SEAL
PROJECT TITLE:
DRAWING TITLE:
DOB No: 320375839
PAGE: OF -
DOB BSCAN STICKER
BROOKLYN, NY 11201
PROJECT TITLE:
PROJECT No: 32130.00
CITY TECH
BUILDINGACADEMIC
285 JAY STREET
KEY PLAN
NO. REVISIONDATE
21 Penn, Plaza, 360 31st Street, 8th Floor
BALMORI ASSOCIATES833 Washington St, 2nd FloorNew York, NY 10014 Tel: 212 431 8616
New York, NY 10001 Tel: 212 479 5400
WSP CANTOR SEINUK
JAROS BAUM & BOLLES
New York, NY 10017 Tel: 212 687 9888228 East 45th Street, 3rd Floor
New York, NY 10005 Tel: 212 530 930080 Pine Street
MEP and FP Engineers:
Landscape Designer:
Structural:
CUNY THE CITY UNIVERSITY OF NEW YORK555 West 57th Street
LANGAN
New York, NY 10019 Tel: 212 541 0468
Civil / Site:
Owner:
47 Water StreetS. Norwalk, CT 06854 Tel: 203 299 0830
Cline Bettridge Berstein
New York, NY 10010 Tel: 212 741 328030 West 22nd Street, 4th Floor
Lighting Design:
Van Deusen & Associates7 Penn Plaza, Suite 404
Shen, Milson & Wilke
Theatre Projects Consultants
New York, NY 10016 Tel: 212 725 6800417 Fifth Avenue
New York, NY 10001 Tel: 212 868 9090
Theater Consultant:
IT and Acoustical Consultant :
Vertical Transporation:
ALT Cladding Limited
141 Thomson Road, Wanchai, Hong Kong Suite 2203-2204 Tai Yip Building
Façade Consultant:
Cerami & Associates, Inc.
New York, NY 10018 Tel: 212 370 1776404 Fifth Avenue
Audiovisual Consultants:
Acoustic Dimensions
New Rochelle, NY 10801 Tel: 914 712 1300145 Huguenot Street, Suite 406
Entek Engineering, LLC
Hackensack, NJ 07601 Tel: 201 820 2801166 Ames Street
Façade Maintenance:
HM WHITE SITE ARCHITECTS107 Grand Street, 6th FloorNew York, NY 10013 Tel: 212 868 9411
Landscape Architect:
Kroll Security Group
New York, NY 10016 Tel: 212 593 1000600 Third Avenue
Security Consultant:
AUDITORIUMPLAN AND SECTIONDETAILS
AS NOTED
A-619.00XX
WALL SECTION THRU VRC/OVERHEAD DOOR6SCALE : 1/4" = 1'-0"
JAMB DETAIL @ AUDITORIUM ROLL-UP DOOR8SCALE : 1 1/2" = 1'-0"
HEAD DETAIL @ AUDITORIUM ROLL-UP DOOR7SCALE : 1 1/2" = 1'-0"
LAYOUT PLAN - VRC5SCALE : 1/4" = 1'-0"
CONSTRUCTION DOCUMENTS
1 09/11/2013 REVISION NO. 151
REV. NO. 1509/11/2013
1REV. NO. 1509/11/2013
320375839 ES087090819DEPT OF BLDGS Job Number Scan Code
APPROVEDUnder Directive 2 of 1975
AMENDED APPLICATION
Date:
Katia Ilieva Asst. Plan Examiner
01/22/2020