    Inquiry, quotation and order formfor actuator controls AUMA MATIC

    AM 01.1AM 02.1

    Issue 1.06

    Y000.212/002/en

    Actuator controls AUMA MATIC AM 01.1 / 02.1 for controlling AUMA multi-turn actuators AUMA NORM SA(R) 07.1 SA(R) 16.1 and part-turnactuators AUMA NORM SG 05.1 SG 12.1 and SG 03.3 SG 05.3.Reference documents: Product description and technical data Actuator controls AUMA MATIC

    Inquiry Project

    Quotation Code

    Order Shipping by:

    Order date : Forw. agent

    Delivery date : Sea freight Air freightQuantity: AM 01.1 AM 02.1

    Ordering code Prices in E

    Basic price AM 01.1

    AM 02.1

    Supply voltage / motor voltage

    other than standard

    Motor controls

    Reversing contactors for motor power up to 1.5 kW( AM 01.1) Reversing contactors for motor power up to 7.5 kW( AM 02.1)

    Reversing contactors for motor power up to 1.5 kW,each contactor 1 NC and 1 NO contact

    50.08

    Reversing contactors for motor power up to 7.5 kW,each contactor 1 NC and 1 NO contact

    50.17

    Reversing contactors for motor power up to 1.5 kW,each contactor 1 NO contact

    50.21

    Reversing contactors for motor power up to 7.5 kW,each contactor 1 NO contact

    50.22

    Thyristor unit instead of reversing contactors for supply voltage up to 500 V, recommendedfor a high number of starts

    for motor power up to 1.5 kW with internal fuses 50.01

    Control

    Control inputs OPEN STOP CLOSE, 24 V DC 46.00 Control inputs OPEN STOP CLOSE, 220 V AC 46.13

    Self-retaining REMOTE included not included

    Voltage output 24V DC, max. 50 mA for supply of the control inputs 49._ _

    115V AC, max. 30 mA for supply of the control inputs (not in combination withPTC tripping device)

    49._ _

    PositionerPositioner with 0/4 20mA input for nominal position value 41.10

    0 20 mA 4 20 mA 20 0 mA 20 4 mA

    Galvanic isolator for position feedback 0/4 20 mArecommended if feedback signal is to be further used in the system

    45._ _

    Position transmitter in actuator Potentiometer (0 5V)

    RWG (0/4 20mA) 0 20 mA 4 20 mA 20 0 mA 20 4 mA

    Fieldbus interfaces Profibus DP according to DIN 19 245, EN 50170 P1+3 41.38

    Modbus RTU 41.44

    Type of seating end pos. CLOSED Type of seating end pos. OPEN Limit seating Torque seating Limit seating Torque seating

    Local controlsSelf-retaining Local included not included

    Selector switch 2nd level (for positioner, ordering code 41.10, included in price adder) 51.02

    Protection cover, lockable 37

    Total carried forward to page 2

    Page 1 of 2

    3-phase AC voltages/frequencies

    400/50 220/50 230/50 240/50 380/50

    415/50 440/60 460/60 480/60 500/50

    1-phase AC voltages/frequencies

    110/60 115/60 120/60 220/50 230/50 240/50

    Note: The respective standard version is printed in bold + italics

  • 7/28/2019 bf_am1_en

    2/2

    AM 01.1AM 02.1

    Issue 1.06Y000.212/002/en

    Inquiry, quotation and order formfor actuator controls AUMA MATIC

    Page 2 of 2

    Ordering code Prices in E

    Motor protection Motor temperature monitoring (thermoswitches in actuator)

    Additional thermal overload relay 54._ _

    PTC tripping device in connection with PTC thermistors in the actuator 54.29

    Enclosure protection IP 67 IP67

    IP 68 IP68

    Terminal compartment additionally sealed against interior (double sealed), possible incombination with IP 67 (IP 67-DS) or IP 68 (IP 68-DS)

    DS

    Cable glands for enclosure protection IP 67 or IP 68. Please state cablediameters

    on request

    Corrosion protection KN incl. painting in standard colour KN

    KS incl. painting in standard colour(recommended for installation in aggressive atmosphere, with a moderate pollutant concentration)

    KS

    KX incl. painting in standard colour(recommended for installation in extremelyaggressive atmosphere, with a high pollutant concentration)

    KX

    Colour other than standard colour (for available colours please contact AUMA)

    Colour

    Special primer / special finish coat

    Accessories Wall bracket for mounting of AUMA MATIC separate from actuator, including plug/

    socket connector, (connecting cables on request).39.1

    Electrical connectionPlug cover with M-threads

    1 x M20 x 1.5 / 2 x M25 x 1.5 S-31 included in basic price

    1 x M20 x 1.5 / 2 x M25 x 1.5 / 1 x M32 x 1.5 SH-148

    1 x M20 x 1.5 / 1 x M25 x 1.5 / 1 x M32 x 1.5 SE-105

    1 x M20 x 1.5 / 2 x M25 x 1.5 Profibus DP S-G-PBD-31 without price adder

    1 x M20 x 1.5 / 2 x M25 x 1.5 Modbus RTU S-G-MOD-31 without price adder

    Plug cover with Pg-threads

    1 x Pg 13.5 / 2 x Pg 21 S-21 without price adder

    1 x Pg 13.5 / 2 x Pg 21 / 1 x Pg 29 SH-26

    1 x Pg 13.5 / 1 x Pg 21 / 1 x Pg 29 SE-03

    1 x Pg 13.5 / 2 x Pg 21 Profibus DP S-G-PBD-21 without price adder 1 x Pg 13.5 / 2 x Pg 21 Modbus RTU S-G-MOD-21 without price adder

    Plug cover with NPT-threads

    1 x " NPT / 2 x " NPT S-74

    2 x " NPT / 1 x 1" NPT SH-80 without price adder

    2 x " NPT / 1 x 1" NPT SE-80

    1 x " NPT / 2 x " NPT Profibus DP S-G-PBD-74 without price adder

    1 x " NPT / 2 x " NPT Modbus RTU S-G-MOD-74 without price adder

    Plug cover with G-threads

    2 x G " / 1 x G 1" / 1 x G 1" SH-178

    2 x G " / 1 x G 1" SH-179

    Special threads

    Control plug gold plated (sockets and pins)recommended in connection with gold contacts in switches

    S-G-xx

    Parking frame for plug, when removed from actuator 95

    Protection cover for plug compartment (when plug is removed) 96.1

    Wiring diagramMSP

    KMS TP

    Total carriedforward from page 1

    Price total / unit

    x quantity

    Price total

    Note: The respective standard version is printed in bold + italics