Upload
kenna-leamon
View
215
Download
1
Embed Size (px)
Citation preview
BERKER B.IQ
08.2013 Ze Bekrer B.IQ 2
DESIGN & VERSIONSCONSTRUCTION & DIMENSIONSSTRUCTURE OF THE DISPLAY PARAMETERTECHNICAL DATA
08.2013 Ze Bekrer B.IQ 3
B.IQDESIGN
Frameless KNX pushbutton
4 different Materials Glass
■Polarwhite
■Black
Aluminium Plastic Stainless steel
08.2013 Ze Bekrer B.IQ 4
B.IQVERISONS
The Berker B.IQ is available in different verions:
1gang
2gang
3gang
4gang
3gang with RTR
4gang with RTR
5gang with RTR
08.2013 Ze Bekrer B.IQ 5
B.IQDESIGN & VERSIONS
Uniform installation height
B.IQ push button 1- 4 gang
B.IQ push button with RTR and display 3 - 5gang
08.2013 Ze Bekrer B.IQ 6
B.IQDESIGN & VERSIONS
Uniform installation height
B.IQ push button 1gang
B.IQ push button 4gang
B.IQ push button with RTR and
display 3gang (also 4gang and 5gang)
08.2013 Ze Bekrer B.IQ 7
B.IQ1- 4GANG STANDARD
Productname:
B.IQ Pushbutton, X-gang
Order No: 7516 x0 9x
08.2013 Ze Bekrer B.IQ 8
B.IQ1- 4GANG STANDARD
with anti-dismantling protection
with blue operation LED and white status LEDs
for switch, push-button, dimmer and shutter functions
dimming / position value transmitter 1 byte
extension unit for light scene push-button
08.2013 Ze Bekrer B.IQ 9
B.IQ1- 4GANG KOMFORT
Productname:
B.IQ Pushbutton, X-gang comfort
Order No: 7516 x5 9x
08.2013 Ze Bekrer B.IQ 10
B.IQ1- 4GANG KOMFORT
Standard functions plus:value transmitter for dimming, position, brightness and temperature values 1 and 2 bytecyclic transmission can also be started via switching objectalarm telegram after disconnection from bus coupling unit 1 bit or 1 bytesingle and two push-button operation parameterisableone push-button operation for switching, pushing, shutters and dimmingactivation of second user level via object
08.2013 Ze Bekrer B.IQ 11
B.IQ3- 5 GANG WITH RTR
Productname:
B.IQ Pushbutton, X-gang with thermostat and display
Order No: 7566 x5 9x
08.2013 Ze Bekrer B.IQ 12
B.IQ3- 5 GANG WITH RTR
with anti-dismantling protection
With blue operation LED and white status LEDs
LC display with symbols and illumination, switchable via object
display of operating mode, controller lockout, room/outside temperature, time (clock required)
text display (ASCII-format)
with 2 additional display buttons
end customer display scope parameterisable
08.2013 Ze Bekrer B.IQ 13
B.IQ3- 5 GANG WITH RTR
for switch, push-button, dimmer, shutter and room thermostat functions
value transmitter for dimming, position, brightness and temperature values 1 and 2 byte
extension unit for light scene push-button
single and two push-button operation parameterisable
one push-button operation for switching, pushing, shutters and dimming
08.2013 Ze Bekrer B.IQ 14
B.IQ3- 5 GANG WITH RTR
area dimming
shutter operation concept short-long-short and long-short parameterisable
alarm telegram after disconnection from bus coupling unit 1 bit, 1 or 2 byte
with room temperature timer and 2-week timer functions
For individual single room temperature control
controller operating modes: comfort, standby, night and frost/heat protection mode
08.2013 Ze Bekrer B.IQ 15
B.IQ3- 5 GANG WITH RTR
for heating and/or cooling mode with/without auxiliary step
control parameter for heating / cooling unit pre-set
temperature measurement via internal and/or external sensor with mean value formation
separate window contact object
indicator objects for heating and cooling
with valve protection function
object for controller status
with flash-controller technology
08.2013 Ze Bekrer B.IQ 16
DESIGN & VERSIONSCONSTRUCTION & DIMENSIONSSTRUCTURE OF THE DISPLAY PARAMETERTECHNICAL DATA
08.2013 Ze Bekrer B.IQ 17
B.IQCONSTRUCTION & DIMENSIONS
Labelling field (optional)
Spacer plate for the display (only required if the labelling field is used)
Base plate with display
Transparent protective cover for the electronics (do not remove or paint over)
Design cover (only to be fitted once all installation work has been completed)
08.2013 Ze Bekrer B.IQ 18
B.IQCONSTRUCTION & DIMENSIONS
Base plate with display
Guide pins
Securing screws for base plate / bus coupling unit supporting ring.
User interface (PEI)
08.2013 Ze Bekrer B.IQ 19
B.IQCONSTRUCTION & DIMENSIONS
Status LEDs
Operating LED
Display / display buttons
Function buttons /
rocker switches
Labelling field
08.2013 Ze Bekrer B.IQ 20
B.IQCONSTRUCTION & DIMENSIONS
08.2013 Ze Bekrer B.IQ 21
DESIGN & VERSIONSCONSTRUCTION & DIMENSIONSSTRUCTURE OF THE DISPLAY PARAMETERTECHNICAL DATA
08.2013 Ze Bekrer B.IQ 22
B.IQSTRUCTURE OF THE DISPLAY
Reserved for future developments
Lower values (left display button)
Accept a change into a sub-menu
“Comfort” operating mode
“Standby” operating mode
“Night” operating mode
Comfort extension (“Night” operating mode)
Frost / heat protection
Heating energy is supplied or control display in the programming
Cooling energy is supplied or control display in the programming
Change the menu item (right display button)
Raise the value (right display button)
Comfort extension (“Frost / heat protection” operating mode)
Switch off room cooling in the event of condensation on the cooling unit
A change made to the required value using the display buttons
Programming mode
Operation of the display buttons or individual rockers or operation of the device locked
Timer active or control display in respective programming
08.2013 Ze Bekrer B.IQ 23
DESIGN & VERSIONSCONSTRUCTION & DIMENSIONSSTRUCTURE OF THE DISPLAY PARAMETERTECHNICAL DATA
B.IQPARAMETER / ETS CONFIGUTATION
The standard and the comfort B.IQ‘s can be configured with Parameters directly in the ETS.
The B.IQ with Display and temperature control needs a plug-in which has to be installed. This is available with the Application on www.berker.com
The next sheets will show the parametration of a RTR B.IQ
08.2013 Ze Bekrer B.IQ 24
08.2013 Ze Bekrer B.IQ 25
B.IQPARAMETER / ETS CONFIGUTATION
Gerneral settings
08.2013 Ze Bekrer B.IQ 26
B.IQPARAMETER / ETS CONFIGUTATION
Display
08.2013 Ze Bekrer B.IQ 27
B.IQPARAMETER / ETS CONFIGUTATION
Push button function
08.2013 Ze Bekrer B.IQ 28
B.IQPARAMETER / ETS CONFIGUTATION
Rocker / Push button function
08.2013 Ze Bekrer B.IQ 29
B.IQPARAMETER / ETS CONFIGUTATION
Status LED
08.2013 Ze Bekrer B.IQ 30
B.IQPARAMETER / ETS CONFIGUTATION
Addressing by drag & drop
08.2013 Ze Bekrer B.IQ 31
B.IQPARAMETER / ETS CONFIGUTATION
Addressing
08.2013 Ze Bekrer B.IQ 32
B.IQPARAMETER / ETS CONFIGUTATION
Room temperature regulation
08.2013 Ze Bekrer B.IQ 33
B.IQPARAMETER / ETS CONFIGUTATION
Room temperature regulation
08.2013 Ze Bekrer B.IQ 34
B.IQPARAMETER / ETS CONFIGUTATION
Temperature measuring
08.2013 Ze Bekrer B.IQ 35
B.IQPARAMETER / ETS CONFIGUTATION
Room temperature regulation
08.2013 Ze Bekrer B.IQ 36
B.IQPARAMETER / ETS CONFIGUTATION
08.2013 Ze Bekrer B.IQ 37
DESIGN & VERSIONSCONSTRUCTION & DIMENSIONSSTRUCTURE OF THE DISPLAY PARAMETERTECHNICAL DATA
08.2013 Ze Bekrer B.IQ 38
B.IQTECHNICAL DATA
Supply Voltage (via bus line): 21–32 V DC
Power consumption (via bus line): typically 360 mW
Controls and displays Rockers (buttons) 3-5 (6-10)
Graphics display with 2 display buttons Two lines with symbol bar
Internal temperature sensor Measuring range 0° C to 40° C
Resolution 0.1 K
Air humidity 0% to 95% (non-condensing)
Internal clock Resolution 1 minute
Gang variation max. 8 minutes a day (use external clock!; update every hour over the bus)
Connections Flush-mounted bus coupling unit plus (7504 00 03)
User interface: 2 x 5-pin male connector
Index of protection IP 20
Ambient temperature range Mode -5 to +45°C
Storage / transportation -20 to +60 °C (storage at over +45°C will reduce the working life)
Assembly Plug into flush-mounted bus coupling unit
Mounting orientation any
Dimensions (W x H x D) depending on design see dimensional drawings
Thanks for your attention
08.2013 Ze Bekrer B.IQ 39