1
1 Part: Stainless Steel Eye Surgery Needle, Outer Diameter 90 microns, Inner Diameter 37 microns, length 2 mm Task: To reduce Outer Diameter to 70 microns and to clean the needle edge from burrs. The aim occurred unreachable by any other methods tried . Problems: 1.To measure and to regulate the working current within the range of 2-3 microamperes 2. To handle a part of micro dimensions Solutions: 1.The current measure was carried out virtually, by calculation based on current field distribution inside the electrolyte. 2. Under microscope manipulated electro- polishing bath was installed for the purpose Results: The task was reached and tens needle were successfully treated and used in lab and clinical experiments Before electropolish: Outer Diameter 90 microns, burrs on the edge After electropolish: Outer Diameter 70 microns, no burrs Ensuring smooth and free of burrs inner surface of configurated juncted optic channels of 2-3 mm diameters, drilled inside a massive stainless steel part. Short-Term R&D Project. Page 1 of 1 TEMPLATE TO BE REPLACED

Before electropolish: Outer Diameter 90 microns, burrs on the edge

Embed Size (px)

DESCRIPTION

Ensuring smooth and free of burrs inner surface of configurated juncted optic channels of 2-3 mm diameters, drilled inside a massive stainless steel part. Short-Term R&D Project. Page 1 of 1 TEMPLATE TO BE REPLACED. - PowerPoint PPT Presentation

Citation preview

Page 1: Before electropolish: Outer Diameter 90 microns, burrs on the edge

1

Part: Stainless Steel Eye Surgery Needle, Outer Diameter 90 microns, Inner Diameter 37 microns, length 2 mm Task: To reduce Outer Diameter to 70 microns and to clean the needle edge from burrs. The aim occurred unreachable by any other methods tried .Problems: 1.To measure and to regulate the working current within the range of 2-3 microamperes2. To handle a part of micro dimensionsSolutions: 1.The current measure was carried out virtually, by calculation based on current field distribution inside the electrolyte.2. Under microscope manipulated electro-polishing bath was installed for the purposeResults: The task was reached and tens needle were successfully treated and used in lab and clinical experiments

Before electropolish: Outer Diameter 90 microns, burrs on the edge

After electropolish: Outer Diameter 70 microns, no burrs

Ensuring smooth and free of burrs inner surface of configurated juncted optic channels of 2-3 mm diameters, drilled inside a massive stainless steel part. Short-Term R&D Project. Page 1 of 1 TEMPLATE TO BE REPLACED