1
BATTEK Battery Management System ANL Fuse Holder Website: http://rimskycheng.wix.com/battek Ebay: http://www.ebay.com/usr/rimskych Dimensions 114± 0.5 38± 1.0 39± 1.0 19.5± 1.0 20± 1.0 ANL Fuseholders are ideal for protecting today’s demanding on- board power electronics technology like Dual Battery System, Au- dio Amplifier, Inverters and Battery Chargers. They also protect wir- ing from short circuits, for example as a main fuse to protect house circuits, protection for digital switching main feed circuits, or heavy duty loads. Installation: 1. Choose mounting location in dry, interior location 2. Screw the fuseholder into chosen location 3. Plain washers must be used on top of fuses 4. Ensure that spring washers are in place beneath cable retaining nuts 5. Recommended torques: • 8mm (5/16”) studs: 12.5 Nm (9.2 lbf) • 10mm (3/8”) studs: 21.5 Nm (15.9 lbf) 6. Ensure that cables are securely fastened and strain relieved as per ABYC/ISO or other applicable standards

BATTEK ANL Fuse Holder

Embed Size (px)

DESCRIPTION

ANL Fuse Holder Technical Specification Features Installation Diagram

Citation preview

Page 1: BATTEK ANL Fuse Holder

BATTEK Battery Management SystemANL Fuse Holder

Website: http://rimskycheng.wix.com/battekEbay: http://www.ebay.com/usr/rimskych

Dimensions

Au plated东莞市赛力特保险丝制造有限公司

CUSTOMER

F

87

E

D

65432

C

B

ASCALE free

OFSHEET

PART NO.

1 1

DSGN

DFTS

CHKD

0.5

0.10 MAX° MAX

APPD0.050.20

MAXR.MAX

87

REVBURR & FLASH

PARTING LINE MISMATCH

BREAK CORNERS

DRAFT ANGLE/SIDE

65432

UNLESS OTHERWISE STATED

1

F

E

D

C

B

A

1

MMMMMM

DEG

.XX

.XXXLINEAR

WALL THICKNESS

ANGULAR

± 0.15

± 0.5

± 0.05

± 0.5

WALL THICKNESS

LINEAR.XX

.X

DEGMMMMMM

A ORIGINAL RELEASE

ASL-011/ANL-H2-B

20091210-011

Tonny 07-12-09

Owen 07-12-09

Bolt12

PB-ANL PA BASE 1BL-ANL 2 carbon steel Au plated

transparent

4NutNT-ANL3

PA+GF 94V0

spacer5 DQ-ANL 4

carbon steel

carbon steel PC 94V01PL-ANL-16 COVER transparent

Au platedcarbon steel Spring4 SP-ANL 2 Au plated

BlackCover7 PL-ANL-1 2 PVC

114± 0.5

38±

1.0

39±

1.0

19.5± 1.0

20±

1.0

Au plated东莞市赛力特保险丝制造有限公司

CUSTOMER

F

87

E

D

65432

C

B

ASCALE free

OFSHEET

PART NO.

1 1

DSGN

DFTS

CHKD

0.5

0.10 MAX° MAX

APPD0.050.20

MAXR.MAX

87

REVBURR & FLASH

PARTING LINE MISMATCH

BREAK CORNERS

DRAFT ANGLE/SIDE

65432

UNLESS OTHERWISE STATED

1

F

E

D

C

B

A

1

MMMMMM

DEG

.XX

.XXXLINEAR

WALL THICKNESS

ANGULAR

± 0.15

± 0.5

± 0.05

± 0.5

WALL THICKNESS

LINEAR.XX

.X

DEGMMMMMM

A ORIGINAL RELEASE

ASL-011/ANL-H2-B

20091210-011

Tonny 07-12-09

Owen 07-12-09

Bolt12

PB-ANL PA BASE 1BL-ANL 2 carbon steel Au plated

transparent

4NutNT-ANL3

PA+GF 94V0

spacer5 DQ-ANL 4

carbon steel

carbon steel PC 94V01PL-ANL-16 COVER transparent

Au platedcarbon steel Spring4 SP-ANL 2 Au plated

BlackCover7 PL-ANL-1 2 PVC

114± 0.5

38±

1.0

39±

1.0

19.5± 1.0

20±

1.0

Au plated东莞市赛力特保险丝制造有限公司

CUSTOMER

F

87

E

D

65432

C

B

ASCALE free

OFSHEET

PART NO.

1 1

DSGN

DFTS

CHKD

0.5

0.10 MAX° MAX

APPD0.050.20

MAXR.MAX

87

REVBURR & FLASH

PARTING LINE MISMATCH

BREAK CORNERS

DRAFT ANGLE/SIDE

65432

UNLESS OTHERWISE STATED

1

F

E

D

C

B

A

1

MMMMMM

DEG

.XX

.XXXLINEAR

WALL THICKNESS

ANGULAR

± 0.15

± 0.5

± 0.05

± 0.5

WALL THICKNESS

LINEAR.XX

.X

DEGMMMMMM

A ORIGINAL RELEASE

ASL-011/ANL-H2-B

20091210-011

Tonny 07-12-09

Owen 07-12-09

Bolt12

PB-ANL PA BASE 1BL-ANL 2 carbon steel Au plated

transparent

4NutNT-ANL3

PA+GF 94V0

spacer5 DQ-ANL 4

carbon steel

carbon steel PC 94V01PL-ANL-16 COVER transparent

Au platedcarbon steel Spring4 SP-ANL 2 Au plated

BlackCover7 PL-ANL-1 2 PVC

114± 0.5

38±

1.0

39±

1.0

19.5± 1.0

20±

1.0

ANL Fuseholders are ideal for protecting today’s demanding on-board power electronics technology like Dual Battery System, Au-dio Amplifier, Inverters and Battery Chargers. They also protect wir-ing from short circuits, for example as a main fuse to protect house circuits, protection for digital switching main feed circuits, or heavy duty loads.Installation:1. Choose mounting location in dry, interior location2. Screw the fuseholder into chosen location3. Plain washers must be used on top of fuses4. Ensure that spring washers are in place beneath cable retaining nuts5. Recommended torques: • 8mm (5/16”) studs: 12.5 Nm (9.2 lbf) • 10mm (3/8”) studs: 21.5 Nm (15.9 lbf)6. Ensure that cables are securely fastened and strain relieved as per ABYC/ISO or other applicable standards