Baterii Automate Varlogic

Embed Size (px)

Citation preview

  • 8/13/2019 Baterii Automate Varlogic

    1/14version: 4.2437E3365 11

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Classic

    Varset is a capacitor bank composed of Varpluscapacitors, speci c contactors for capacitor switchingand a Varlogic power factor controller. It is offered in

    two models, with or without incoming circuit breaker.It is presented in enclosures or cubicles with differentheight. It is available in Classic, Comfort and Harmonyaccording to the level of harmonic pollution.

    Varset Classic "without incoming circuit breaker"No polluted network (Gh/Sn y 15 %)

    Varset Classic "without incoming circuit breaker"400 V(kvar)

    Step Type Ref. 400 V(kvar)

    Step Type Ref.

    7.5 3x2.5 Enclosure C1 52831 225 15x15 Cubicle A2 5290910 4x2.5 Enclosure C1 52833 240 8x30 Cubicle A2 5291112.5 5x2.5 Enclosure C1 52835 6x40 Cubicle A1 5291315 3x5 Enclosure C1 52837 270 18x15 Cubicle A3 5291517.5 7x2.5 Enclosure C1 52839 9x30 Cubicle A2 5291720 4x5 Enclosure C1 52841 280 7x40 Cubicle A2 5291922.5 3x7.5 Enclosure C1 52843 300 5x60 Cubicle A2 5292125 5x5 Enclosure C1 52845 10x30 Cubicle A3 5292327.5 2.5x11 Enclosure C2 52847 320 8x40 Cubicle A2 5292530 3x10 Enclosure C1 52849 330 11x30 Cubicle A2 52927

    6x5 Enclosure C1 52851 360 12x30 Cubicle A3 5292935 7x5 Enclosure C1 52853 9x40 Cubicle A2 52931

    40 4x10 Enclosure C1 52855 390 13x30 Cubicle A3 529338x5 Enclosure C2 52857 400 10x40 Cubicle A3 52935

    45 3x15 Enclosure C1 52859 420 7x60 Cubicle A3 529379x5 Enclosure C2 52861 14x30 Cubicle A3 52939

    50 5x10 Enclosure C1 52863 450 15x30 Cubicle A3 5294155 11x5 Enclosure C2 52865 480 8x60 Cubicle A3 5294360 6x10 Enclosure C2 52867 12x40 Cubicle A3 52945

    12x5 Enclosure C2 52869 510 17x30 Cubicle A3 5294765 13x5 Enclosure C2 52871 520 13x40 Cubicle A3 5294970 7x10 Enclosure C2 52873 540 9x60 Cubicle A3 5295175 5x15 Enclosure C2 52875 570 19x30 Cubicle A3 5295380 4x20 Enclosure C2 52877 600 15x40 Cubicle A3 5295590 6x15 Enclosure C2 52879 10x60 Cubicle A3 52957

    9x10 Enclosure C2 52881 660 11x60 Cubicle A4 52959100 5x20 Enclosure C2 52883 720 12x60 Cubicle A4 52961

    105 7x15 Enclosure C2 52885 780 13x60 Cubicle A4 52963120 8x15 Cubicle A1 52887 840 14x60 Cubicle A4 52965

    6x20 Enclosure C2 52889 900 15x60 Cubicle A4 52967135 9x15 Cubicle A1 52891 960 8x120 Cubicle A4 52969140 7x20 Cubicle A1 52893 16x60 Cubicle A4 52971150 10x15 Cubicle A1 52895 1020 17x60 Cubicle A4 52973160 8x20 Cubicle A1 52897 1080 18x60 Cubicle A4 52975165 11x15 Cubicle A1 52899 9x120 Cubicle A4 52977180 9x20 Cubicle A1 52901 1140 19x60 Cubicle A4 52979195 13x15 Cubicle A2 52903 1200 20x60 Cubicle A4 52981200 5x40 Cubicle A1 52905 10x120 Cubicle A4 52983210 14x15 Cubicle A2 52907

    Technical data b capacitor rated voltage: 415 V, 3-phase 50 Hz b capacitance value tolerance: -5, +10 % b insulation level: v 0.69 kV v withstand 50 Hz 1 min: 2.5 kV b maximum permissible current: 30 % max. (400 V) b maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 10 % b ambiant temperature around the equipment (electrical room): v maximum temperature: 40 C v average temperature over 24 hrs: 35 C v average annual temperature: 25 C v minimum temperature: -5 C b degree of protection:

    v enclosure: IP31 v cubicle: IP31 (except on outlet fan: IP21D) b load shedding (main-standby) b transformer 400/230 V integrated

    b protection against direct contact (opened door) b colour: RAL 9001 b standards: IEC 60439-1, EN 60439-1, IEC 61921.

    Accessory for Varset Classic "without incoming circuit breaker" Ref.Free-standing plinth for enclosures C1 and C2 65980

    P B 1 0 2 0 4 1

    _ S E

    - 3 0

    Enclosures C1 and C2 without incoming circuit breaker.

    P B 1 0 2 0 2 0

    _ S E

    - 5 5

    Cubicles without incoming circuit breaker.

  • 8/13/2019 Baterii Automate Varlogic

    2/14version: 4.2 437E336522

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Classic

    Installation b xing:

    v

    enclosure: wall mounting or by free standing plinth (accessory) with topconnection of power cables v cubicle: free standing cubicle with bottom connection of power cables to the

    busbar pads b the CT (5 VA sec. 5 A), not supplied, has to be placed upstream from the capacitor

    bank and loads b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactor

    coils.

    Options b xed base compensation b extension b top connection b please consult us for other options.

    DimensionsVarset Classic "without incoming circuit breaker"400 V (kvar) Type Dimensions (mm) Weight

    (kg)H W D7.5 to 25, 30 and 35 Enclosure C1 450 500 275 2027.5 Enclosure C2 800 500 275 2540 4x10 Enclosure C1 450 500 275 20

    8x5 Enclosure C2 800 500 275 2545 3x15 Enclosure C1 450 500 275 30

    9x5 Enclosure C2 800 500 275 3050 Enclosure C1 450 500 275 2555 Enclosure C2 800 500 275 2560, 65 and 70 Enclosure C2 800 500 275 4075 and 80 Enclosure C2 800 500 275 4590, 100 and 105 Enclosure C2 800 500 275 50120 8x15 Cubicle A1 1100 550 600 60

    6x20 Enclosure C2 800 500 275 50135 to 160 Cubicle A1 1100 550 600 60165 and 180 Cubicle A1 1100 550 600 65195 Cubicle A2 1100 800 600 85200 Cubicle A1 1100 550 600 65210 Cubicle A2 1100 800 600 85225 Cubicle A2 1100 800 600 85240 8x30 Cubicle A2 1100 800 600 80

    6x40 Cubicle A1 1100 550 600 70270 18x15 Cubicle A3 2000 800 600 150

    9x30 Cubicle A2 1100 800 600 95280 Cubicle A2 1100 800 600 95300 5x60 Cubicle A2 1100 800 600 95

    10x30 Cubicle A3 2000 800 600 155320 and 330 Cubicle A2 1100 800 600 100360 12x30 Cubicle A3 2000 800 600 165

    9x40 Cubicle A2 1100 800 600 105390 Cubicle A3 2000 800 600 180400 Cubicle A3 2000 800 600 155420 7x60 Cubicle A3 2000 800 600 155

    14x30 Cubicle A3 2000 800 600 155450 Cubicle A3 2000 800 600 165480 8x60 Cubicle A3 2000 800 600 160

    12x40 Cubicle A3 2000 800 600 165510 Cubicle A3 2000 800 600 180520 Cubicle A3 2000 800 600 180540 Cubicle A3 2000 800 600 180570 Cubicle A3 2000 800 600 185600 15x40 Cubicle A3 2000 800 600 190

    10x60 Cubicle A3 2000 800 600 195660 and 720 Cubicle A4 2000 1600 600 340780 and 840 Cubicle A4 2000 1600 600 360900 Cubicle A4 2000 1600 600 370

    960 8x120 Cubicle A4 2000 1600 600 37016x60 Cubicle A4 2000 1600 600 385

    1020 Cubicle A4 2000 1600 600 3851080 Cubicle A4 2000 1600 600 4501140 Cubicle A4 2000 1600 600 4501200 Cubicle A4 2000 1600 600 450

    Cubicles A1 and A2 withoutincoming circuit breaker.

    D B 1 1 0 6 3 2

    _ 1

    Cubicle A3 without incomingcircuit breaker.

    D B 1 1 0 6 3 7

    _ 1

    Cubicle A4 without incoming circuit breaker.

    D B 1 1 0 6 4 0

    _ 1

    Enclosures C1 withoutincoming circuit breaker.

    D B 1 1 0 6 3 4

    _ 1

    Enclosures C2 withoutincoming circuit breaker.

    D B 1 1 0 6 2 7

    _ 1

  • 8/13/2019 Baterii Automate Varlogic

    3/14version: 4.2437E3365 33

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Classic

    Varset is a capacitor bank composed of Varpluscapacitors, speci c contactors for capacitor switchingand a Varlogic power factor controller. It is offered in

    two models, with or without incoming circuit breaker.It is presented in enclosures or cubicles with differentheight. It is available in Classic, Comfort and Harmonyaccording to the level of harmonic pollution.

    Varset Classic "with incoming circuit breaker"No polluted network (Gh/Sn y 15 %)

    Varset Classic "with incoming circuit breaker"400 V(kvar)

    Step Type Ref. 400 V(kvar)

    Step Type Ref.

    7.5 3x2.5 Enclosure C1 52832 225 15x15 Cubicle A3 5291010 4x2.5 Enclosure C1 52834 240 8x30 Cubicle A3 5291212.5 5x2.5 Enclosure C1 52836 6x40 Cubicle A2 5291415 3x5 Enclosure C1 52838 270 18x15 Cubicle A3 5291617.5 7x2.5 Enclosure C1 52840 9x30 Cubicle A3 5291820 4x5 Enclosure C1 52842 280 7x40 Cubicle A3 5292022.5 3x7.5 Enclosure C1 52844 300 5x60 Cubicle A3 5292225 5x5 Enclosure C1 52846 10x30 Cubicle A3 5292427.5 2.5x11 Enclosure C2 52848 320 8x40 Cubicle A3 5292630 3x10 Enclosure C1 52850 330 11x30 Cubicle A3 52928

    6x5 Enclosure C1 52852 360 12x30 Cubicle A3 5293035 7x5 Enclosure C1 52854 9x40 Cubicle A3 52932

    40 4x10 Enclosure C1 52856 390 13x30 Cubicle A3 529348x5 Enclosure C2 52858 400 10x40 Cubicle A3 52936

    45 3x15 Enclosure C1 52860 420 7x60 Cubicle A3 529389x5 Enclosure C2 52862 14x30 Cubicle A3 52940

    50 5x10 Enclosure C1 52864 450 15x30 Cubicle A3 5294255 11x5 Enclosure C2 52866 480 8x60 Cubicle A3 5294460 6x10 Enclosure C2 52868 12x40 Cubicle A3 52946

    12x5 Enclosure C2 52870 510 17x30 Cubicle A3 5294865 13x5 Enclosure C2 52872 520 13x40 Cubicle A3 5295070 7x10 Enclosure C2 52874 540 9x60 Cubicle A3 5295275 5x15 Enclosure C2 52876 570 19x30 Cubicle A3 5295480 4x20 Enclosure C2 52878 600 15x40 Cubicle A3 5295690 6x15 Enclosure C2 52880 10x60 Cubicle A3 52958

    9x10 Enclosure C2 52882 660 11x60 Cubicle A4 52960100 5x20 Enclosure C2 52884 720 12x60 Cubicle A4 52962

    105 7x15 Enclosure C2 52886 780 13x60 Cubicle A4 52964120 8x15 Cubicle A2 52888 840 14x60 Cubicle A4 52966

    6x20 Enclosure C2 52890 900 15x60 Cubicle A4 52968135 9x15 Cubicle A2 52892 960 8x120 Cubicle A4 52970140 7x20 Cubicle A2 52894 16x60 Cubicle A4 52972150 10x15 Cubicle A2 52896 1020 17x60 Cubicle A4 52974160 8x20 Cubicle A2 52898 1080 18x60 Cubicle A4 52976165 11x15 Cubicle A2 52900 9x120 Cubicle A4 52978180 9x20 Cubicle A2 52902 1140 19x60 Cubicle A4 52980195 13x15 Cubicle A3 52904 1200 20x60 Cubicle A4 52982200 5x40 Cubicle A2 52906 10x120 Cubicle A4 52984210 14x15 Cubicle A3 52908

    Technical data b capacitor rated voltage: 415 V, 3-phase 50 Hz b capacitance value tolerance: -5, +10 % b insulation level: v 0.69 kV v withstand 50 Hz 1 min: 2.5 kV b maximum permissible current: 30 % max. (400 V) b maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 10 % b ambiant temperature around the equipment (electrical room): v maximum temperature: 40 C v average temperature over 24 hrs: 35 C v average annual temperature: 25 C v minimum temperature: -5 C b degree of protection:

    v enclosure: IP31 v cubicle: IP31 (except on outlet fan: IP21D) b load shedding (main-standby) b transformer 400/230 V integrated

    b protection against direct contact (opened door) b colour: RAL 9001 b standards: IEC 60439-1, EN 60439-1, IEC 61921.

    Accessory for Varset Classic "with incoming circuit breaker" Ref.Free-standing plinth for enclosures C1 and C2 65980

    P B 1 0 2 0 4 1

    _ S E

    - 3 0

    Enclosures C1 and C2 withincoming circuit breaker.

    P B 1 0 2 0 1 0

    _ S E

    - 5 5

    Cubicle A2 with incomingcircuit breaker.

    P B 1 0 2 0 0 9

    _ S E

    - 6 0 2

    Cubicles A3 and A4 withincoming circuit breaker.

  • 8/13/2019 Baterii Automate Varlogic

    4/14version: 4.2 437E336544

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Classic

    Installation b xing:

    v

    enclosure: wall mounting or by free standing plinth (accessory) with topconnection of power cables v cubicle: free standing cubicle with bottom connection of power cables to the

    busbar pads b the CT (5 VA sec. 5 A), not supplied, has to be placed upstream from the capacitor

    bank and loads b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactor

    coils.

    Options b xed base compensation b extension b top connection b please consult us for other options.

    DimensionsVarset Classic "with incoming circuit breaker"400 V (kvar) Type Dimensions (mm) Weight

    (kg)H W D7.5 to 25 Enclosure C1 450 500 275 2227.5 Enclosure C2 800 500 275 2730 and 35 Enclosure C1 450 500 275 2240 4x10 Enclosure C1 450 500 275 22

    8x5 Enclosure C2 800 500 275 2745 3x15 Enclosure C1 450 500 275 32

    9x5 Enclosure C2 800 500 275 3250 Enclosure C1 450 500 275 2755 Enclosure C2 800 500 275 2760, 65 and 70 Enclosure C2 800 500 275 4275 and 80 Enclosure C2 800 500 275 4790, 100 and 105 Enclosure C2 800 500 275 52120 8x15 Cubicle A2 1100 800 600 62

    6x20 Enclosure C2 800 500 275 52135 to 160 Cubicle A2 1100 800 600 62165 and 180 Cubicle A2 1100 800 600 67195 Cubicle A3 2000 800 600 150200 Cubicle A2 1100 800 600 70210 Cubicle A3 2000 800 600 150225 Cubicle A3 2000 800 600 150240 8x30 Cubicle A3 2000 800 600 150

    6x40 Cubicle A2 1100 800 600 70270, 280 Cubicle A3 2000 800 600 155300 5x60 Cubicle A3 2000 800 600 160

    10x30 Cubicle A3 2000 800 600 165320, 330 Cubicle A3 2000 800 600 165330, 360 Cubicle A3 2000 800 600 165390 Cubicle A3 2000 800 600 210400 Cubicle A3 2000 800 600 185420 7x60 Cubicle A3 2000 800 600 185

    14x30 Cubicle A3 2000 800 600 185450 Cubicle A3 2000 800 600 195480 8x60 Cubicle A3 2000 800 600 190

    12x40 Cubicle A3 2000 800 600 195510 Cubicle A3 2000 800 600 210520 Cubicle A3 2000 800 600 210540 Cubicle A3 2000 800 600 210570 Cubicle A3 2000 800 600 215600 15x40 Cubicle A3 2000 800 600 220

    10x60 Cubicle A3 2000 800 600 225660, 720 Cubicle A4 2000 1600 600 370780, 840 Cubicle A4 2000 1600 600 390900 Cubicle A4 2000 1600 600 400960 8x120 Cubicle A4 2000 1600 600 400

    16x60 Cubicle A4 2000 1600 600 4151020 Cubicle A4 2000 1600 600 4151080, 1140 and 1200 Cubicle A4 2000 1600 600 430

    Cubicle A2 with incoming circuit breaker.

    D B 1 1 0 6 3 1

    _ 1

    Cubicle A3 with incoming circuit breaker.

    D B 1 1 0 6 3 8

    _ 1

    Cubicle A4 with incoming circuit breaker.

    D B 1 1 0 6 3 9

    _ 1

    Enclosures C1 withincoming circuit breaker.

    D B 1 1 0 6 3 3

    _ 1

    Enclosures C2 with incomingcircuit breaker.

    D B 1 1 0 6 2 6

    _ 1

  • 8/13/2019 Baterii Automate Varlogic

    5/14version: 4.2437E3365 55

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Comfort

    Varset is a capacitor bank composed of Varpluscapacitors, speci c contactors for capacitor switchingand a Varlogic power factor controller. It is offered in

    two models, with or without incoming circuit breaker.It is presented in enclosures or cubicles with differentheight. It is available in Classic, Comfort and Harmonyaccording to the level of harmonic pollution.

    Varset Comfort "without incoming circuit breaker"Polluted network (15 % < Gh/Sn y 25 %)

    Varset Comfort "without incoming circuit breaker"400 V (kvar) Step Type Ref.30 4x7.5 Enclosure C1 6550145 6x7.5 Enclosure C2 6550360 8x7.5 Enclosure C2 6550575 5x15 Enclosure C2 6550790 6x15 Enclosure C2 65509105 7x15 Cubicle A1 65511120 8x15 Cubicle A1 65513150 5x30 Cubicle A1 65515180 6x30 Cubicle A1 65517210 7x30 Cubicle A2 65519240 8x30 Cubicle A2 65521270 9x30 Cubicle A2 65523315 7x45 Cubicle A3 65525

    360 8x45 Cubicle A3 65527405 9x45 Cubicle A3 65529450 5x90 Cubicle A3 65531495 11x45 Cubicle A4 65533540 6x90 Cubicle A4 65535585 13x45 Cubicle A4 65537630 7x90 Cubicle A4 65539675 15x45 Cubicle A4 65541720 8x90 Cubicle A4 65543765 17x45 Cubicle A4 65545810 9x90 Cubicle A4 65547855 19x45 Cubicle A4 65549900 10x90 Cubicle A4 65551

    Technical data b capacitor rated voltage: 480 V, 3-phase 50 Hz b capacitance value tolerance: -5, +10 % b insulation level: v 0.69 kV v withstand 50 Hz 1 min: 2.5 kV b maximum permissible current: 30 % max. (400 V) b maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 10 % b ambiant temperature around the equipment (electrical room): v maximum temperature: 40 C v average temperature over 24 hrs: 35 C v average annual temperature: 25 C v minimum temperature: -5 C b degree of protection:

    v enclosure: IP31 v cubicle: IP31 (except on outlet fan: IP21D) b load shedding (main-standby)

    b transformer 400/230 V integrated b protection against direct contact (opened door) b colour: RAL 9001 b standards: IEC 60439-1, EN 60439-1, IEC 61921.

    Accessory for Varset Comfort "without incoming circuit breaker" Ref.Free-standing plinth for enclosures C1 and C2 65980

    Enclosures C1 and C2 withoutincoming circuit breaker.

    P B 1 0 2 0 1 0

    _ S E

    - 5 5

    Cubicles A1 and A2 without incoming circuit breaker.

    P B 1 0 2 0 0 9

    _ S E

    - 6 0 2

    Cubicles A3 and A4 withoutincoming circuit breaker.

    P B 1 0 2 0 1 1

    _ S E

    - 4 5

    P B 1 0 2 0 4 1

    _ S E

    - 3 0

  • 8/13/2019 Baterii Automate Varlogic

    6/14

  • 8/13/2019 Baterii Automate Varlogic

    7/14version: 4.2437E3365 77

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Comfort

    Varset is a capacitor bank composed of Varpluscapacitors, speci c contactors for capacitor switchingand a Varlogic power factor controller. It is offered in

    two models, with or without incoming circuit breaker.It is presented in enclosures or cubicles with differentheight. It is available in Classic, Comfort and Harmonyaccording to the level of harmonic pollution.

    Varset Comfort "with incoming circuit breaker"Polluted network (15 % < Gh/Sn y 25 %)

    Varset Comfort "with incoming circuit breaker"400 V (kvar) Step Type Ref.30 4x7.5 Enclosure C1 6550045 6x7.5 Enclosure C2 6550260 8x7.5 Enclosure C2 6550475 5x15 Enclosure C2 6550690 6x15 Enclosure C2 65508105 7x15 Cubicle A2 65510120 8x15 Cubicle A2 65512150 10x15 Cubicle A2 65514180 6x30 Cubicle A2 65516210 7x30 Cubicle A3 65518240 8x30 Cubicle A3 65520270 9x30 Cubicle A3 65522315 7x45 Cubicle A3 65524

    360 8x45 Cubicle A3 65526405 9x45 Cubicle A3 65528450 5x90 Cubicle A3 65530495 11x45 Cubicle A4 65532540 6x90 Cubicle A4 65534585 13x45 Cubicle A4 65536630 7x90 Cubicle A4 65538675 15x45 Cubicle A4 65540720 8x90 Cubicle A4 65542765 17x45 Cubicle A4 65544810 9x90 Cubicle A4 65546855 19x45 Cubicle A4 65548900 10x90 Cubicle A4 65550

    Technical data b capacitor rated voltage: 480 V, 3-phase 50 Hz b capacitance value tolerance: -5, +10 % b insulation level: v 0.69 kV v withstand 50 Hz 1 min: 2.5 kV b maximum permissible current: 30 % max. (400 V) b maximum permissible voltage (8 hours over 24 hours as in IEC 60831): 10 % b ambiant temperature around the equipment (electrical room): v maximum temperature: 40 C v average temperature over 24 hrs: 35 C v average annual temperature: 25 C v minimum temperature: -5 C b degree of protection:

    v enclosure: IP31 v cubicle: IP31 (except on outlet fan: IP21D) b load shedding (main-standby) b transformer 400/230 V integrated b protection against direct contact (opened door) b colour: RAL 9001 b standards: IEC 60439-1, EN 60439-1, IEC 61921.

    Accessory for Varset comfort "with incoming circuit breaker" Ref.Free-standing plinth for enclosures C1 and C2 65980

    Enclosures C1 and C2 withincoming circuit breaker.

    P B 1 0 2 0 1 0

    _ S E

    - 5 5

    Cubicle A2 with incomingcircuit breaker.

    P B 1 0 2 0 0 9

    _ S E

    - 6 0 1

    Cubicles A3 and A4 withincoming circuit breaker.

    P B 1 0 2 0 4 1

    _ S E

    - 3 0

  • 8/13/2019 Baterii Automate Varlogic

    8/14version: 4.2 437E336588

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Comfort

    Installation b xing:

    v

    enclosure: wall mounting or by free standing plinth (accessory) with topconnection of power cables v cubicle: free standing cubicle with bottom connection of power cables to the

    busbar pads b the CT (5 VA sec. 5 A), not supplied, has to be placed upstream from the capacitor

    bank and loads b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactor

    coils.

    Options b xed base compensation b extension b top connection b please consult us for other options.

    DimensionsVarset Comfort "with incoming circuit breaker"400 V (kvar) Type Dimensions (mm) Weight

    (kg)H W D30 Enclosure C1 450 500 275 2345 Enclosure C2 800 500 275 4360 Enclosure C2 800 500 275 4875 Enclosure C2 800 500 275 4890 Enclosure C2 800 500 275 53105 Cubicle A2 1100 800 600 85120 Cubicle A2 1100 800 600 85150 Cubicle A2 1100 800 600 85180 Cubicle A2 1100 800 600 85210 Cubicle A3 2000 800 600 190240 Cubicle A3 2000 800 600 200270 Cubicle A3 2000 800 600 210315 Cubicle A3 2000 800 600 220360 Cubicle A3 2000 800 600 355405 Cubicle A3 2000 800 600 360450 Cubicle A3 2000 800 600 375495 Cubicle A4 2000 1600 600 355540 Cubicle A4 2000 1600 600 360585 Cubicle A4 2000 1600 600 375630 Cubicle A4 2000 1600 600 380675 Cubicle A4 2000 1600 600 385720 Cubicle A4 2000 1600 600 390765 Cubicle A4 2000 1600 600 405810 Cubicle A4 2000 1600 600 410855 Cubicle A4 2000 1600 600 425900 Cubicle A4 2000 1600 600 430

    Cubicle A2 with incoming circuit breaker.

    D B 1 1 0 6 3 1

    _ 1

    Cubicle A3 with incoming circuit breaker.

    D B 1 1 0 6 3 8

    _ 1

    Cubicle A4 with incoming circuit breaker.

    D B 1 1 0 6 3 9

    _ 1

    Enclosures C1 withincoming circuit breaker.

    D B 1 1 0 5 6 3

    Enclosures C2 withincoming circuit breaker.

    D B 1 1 0 5 5 3

  • 8/13/2019 Baterii Automate Varlogic

    9/14

  • 8/13/2019 Baterii Automate Varlogic

    10/14version: 4.2 437E33651010

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Harmony

    Installation b cubicle: free standing cubicle with bottom connection of power cables to the

    busbar pads b the CT (5 VA sec. 5 A), not supplied, has to be placed upstream from the capacitorbank and loads

    b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactorcoils.

    Options b xed base compensation b extension b top connection b please consult us for other options.

    DimensionsVarset Harmony "without incoming circuit breaker"Tuning order 400 V (kvar) Type Dimensions (mm) Weight

    (kg)H W D2.7(135 Hz)

    12 Cubicle A2 1100 800 600 10525 Cubicle A2 1100 800 600 11537 Cubicle A2 1100 800 600 12550 Cubicle A2 1100 800 600 13562 Cubicle A2 1100 800 600 14575 3x25 Cubicle A2 1100 800 600 155

    6x12.5 Cubicle A3 2000 800 600 200100 4x25 Cubicle A2 1100 800 600 175

    8x12.5 Cubicle A3 2000 800 600 220125 Cubicle A2 1100 800 600 195137 Cubicle A3 2000 800 600 250150 6x25 Cubicle A3 2000 800 600 300

    3x50 Cubicle A2 1100 800 600 195175 Cubicle A3 2000 800 600 330200 Cubicle A3 2000 800 600 360225 Cubicle A3 2000 800 600 380250 Cubicle A3 2000 800 600 400275 Cubicle A3 2000 800 600 420300 Cubicle A3 2000 800 600 440350 Cubicle A4 2000 1600 600 520375 Cubicle A4 2000 1600 600 540400 Cubicle A4 2000 1600 600 560450 Cubicle A4 2000 1600 600 600500 Cubicle A4 2000 1600 600 640550 Cubicle A4 2000 1600 600 680600 12x50 Cubicle A4 2000 1600 600 720

    6x100 Cubicle A4 2000 1600 600 720700 Cubicles A4+A3 2000 2400 600 1000800 Cubicles A4+A3 2000 2400 600 1080900 Cubicles A4+A3 2000 2400 600 11801000 Cubicles A4+A3 2000 2400 600 12801050 Cubicles A4+A3 2000 2400 600 13601200 Cubicles A4+A3 2000 2400 600 1440

    Cubicle A2 without incomingcircuit breaker.

    D B 1 1 0 6 3 0

    _ 1

    Cubicle A3 without incomingcircuit breaker.

    D B 1 1 0 6 3 7

    _ 1

    Cubicle A4 without incoming circuit breaker.

    D B 1 1 0 6 4 0

    _ 1

  • 8/13/2019 Baterii Automate Varlogic

    11/14version: 4.2437E3365 1111

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Harmony

    Dimensions (cont.)Varset Harmony "without incoming circuit breaker"

    Tuningorder

    400 V (kvar) Type Dimensions (mm) Weight(kg)H W D

    3.8 (190 Hz) 12 Cubicle A2 1100 800 600 10525 Cubicle A2 1100 800 600 11537 Cubicle A2 1100 800 600 12550 Cubicle A2 1100 800 600 13562 Cubicle A2 1100 800 600 14575 3x25 Cubicle A2 1100 800 600 155

    6x12.5 Cubicle A3 2000 800 600 200100 4x25 Cubicle A2 1100 800 600 175

    8x12.5 Cubicle A3 2000 800 600 220125 Cubicle A2 1100 800 600 195137 Cubicle A3 2000 800 600 250150 6x25 Cubicle A3 2000 800 600 300

    3x50 Cubicle A2 1100 800 600 195

    175 Cubicle A3 2000 800 600 330200 Cubicle A3 2000 800 600 360225 Cubicle A3 2000 800 600 380250 Cubicle A3 2000 800 600 400275 Cubicle A3 2000 800 600 420300 Cubicle A3 2000 800 600 440350 Cubicle A4 2000 1600 600 520375 Cubicle A4 2000 1600 600 540400 Cubicle A4 2000 1600 600 560450 Cubicle A4 2000 1600 600 600500 Cubicle A4 2000 1600 600 640550 Cubicle A4 2000 1600 600 680600 Cubicle A4 2000 1600 600 720700 Cubicles A4+A3 2000 2400 600 1000800 Cubicles A4+A3 2000 2400 600 1080

    900 Cubicles A4+A3 2000 2400 600 11801000 Cubicles A4+A4 2000 3200 600 12801050 Cubicles A4+A4 2000 3200 600 13601200 Cubicles A4+A4 2000 3200 600 1440

    4.3 (215Hz) 12.5 Cubicle A2 1100 800 600 10525 Cubicle A2 1100 800 600 11537.5 Cubicle A2 1100 800 600 12550 Cubicle A2 1100 800 600 13562.5 Cubicle A2 1100 800 600 14575 3x25 Cubicle A2 1100 800 600 155

    6x12.5 Cubicle A3 2000 800 600 200100 4x25 Cubicle A2 1100 800 600 175

    8x12.5 Cubicle A3 2000 800 600 220125 Cubicle A2 1100 800 600 195137 Cubicle A3 2000 800 600 250

    150 6x25 Cubicle A3 2000 800 600 3003x50 Cubicle A2 1100 800 600 195

    175 Cubicle A3 2000 800 600 330200 Cubicle A3 2000 800 600 360225 Cubicle A3 2000 800 600 380250 Cubicle A3 2000 800 600 400275 Cubicle A3 2000 800 600 420300 Cubicle A3 2000 800 600 440350 Cubicle A4 2000 1600 600 520375 Cubicle A4 2000 1600 600 540400 Cubicle A4 2000 1600 600 560450 Cubicle A4 2000 1600 600 600500 Cubicle A4 2000 1600 600 640550 Cubicle A4 2000 1600 600 680600 Cubicle A4 2000 1600 600 720

    700 Cubicles A4+A3 2000 2400 600 1000800 Cubicles A4+A3 2000 2400 600 1080900 Cubicles A4+A3 2000 2400 600 11801000 Cubicles A4+A4 2000 3200 600 12801050 Cubicles A4+A4 2000 3200 600 13601200 Cubicles A4+A4 2000 3200 600 1440

    Cubicle A2 without incoming circuit breaker.

    D B 1 1 0 6 3 0

    _ 1

    Cubicle A3 without incoming circuit breaker.

    D B 1 1 0 6 3 7

    _ 1

    Cubicle A4 without incoming circuit breaker.

    D B 1 1 0 6 4 0

    _ 1

  • 8/13/2019 Baterii Automate Varlogic

    12/14

  • 8/13/2019 Baterii Automate Varlogic

    13/14version: 4.2437E3365 1313

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Harmony

    Installation b cubicle: free standing cubicle with bottom connection of power cables to the

    busbar pads b the CT (5 VA sec. 5 A), not supplied, has to be placed upstream from the capacitorbank and loads

    b it is not necessary to provide a 230 V/50 Hz power supply to supply the contactorcoils.

    Options b xed base compensation b extension b top connection b please consult us for other options.

    DimensionsVarset Harmony "with incoming circuit breaker"Tuningorder

    400 V (kvar) Type Dimensions (mm) Weight(kg)H W D

    2.7(135 Hz)

    12 Cubicle A2 1100 800 600 17025 Cubicle A2 2000 1350 600 18037 Cubicle A2 2000 1350 600 19050 Cubicle A2 2000 1350 600 20062 Cubicle A2 2000 1350 600 21575 3x25 Cubicle A2 2000 1350 600 225

    6x12.5 Cubicle A3B 2000 1350 600 270100 4x25 Cubicle A2 2000 1350 600 245

    8x12.5 Cubicle A3B 2000 1350 600 290125 Cubicle A2 2000 1350 600 265137 Cubicle A3B 2000 1350 600 320150 Cubicle A3B+A2 2000 1350 600 370175 Cubicle A3B 2000 1350 600 400200 Cubicle A3B 2000 1350 600 430225 Cubicle A3B 2000 1350 600 450250 Cubicle A3B 2000 1350 600 470275 Cubicle A3B 2000 1350 600 490300 Cubicle A3B 2000 1350 600 510350 Cubicle A4B 2000 2150 600 590375 Cubicle A4B 2000 2150 600 610400 Cubicle A4B 2000 2150 600 630450 Cubicle A4B 2000 2150 600 670500 Cubicle A4B 2000 2150 600 710550 Cubicle A4B 2000 2150 600 750600 Cubicle A4B 2000 2150 600 790700 Cubicles A4B+A3B 2000 3500 600 1140800 Cubicles A4B+A3B 2000 3500 600 1220900 Cubicles A4B+A3B 2000 3500 600 13201000 Cubicles A4B+A3B 2000 4300 600 14201050 Cubicles A4B+A3B 2000 4300 600 15001200 Cubicles A4B+A3B 2000 4300 600 1580

    Cubicle A3B with incoming circuit breaker.

    D B 1 1 0 6 3 6

    _ 1

    Cubicle A4B with incoming circuit breaker.

    D

    B 1 1 0 6 3 5

    _ 1

  • 8/13/2019 Baterii Automate Varlogic

    14/14

    Power factor correctionand harmonic filtering

    Capacitors and banks 50 Hz400/415 V network voltageVarset Harmony

    Dimensions (cont.)Varset Harmony "with incoming circuit breaker"

    Tuningorder

    400 V (kvar) Type Dimensions (mm) Weight(kg)H W D

    3.8(190 Hz)

    12 Cubicle A2 2000 1350 600 17025 Cubicle A2 2000 1350 600 18037 Cubicle A2 2000 1350 600 19050 Cubicle A2 2000 1350 600 20062 Cubicle A2 2000 1350 600 21575 3x25 Cubicle A3B 2000 1350 600 225

    6x12.5 Cubicle A3B 2000 1350 600 270100 4x25 Cubicle A3B 2000 1350 600 245

    8x12.5 Cubicle A3B 2000 1350 600 290125 Cubicle A2 2000 1350 600 265137 Cubicle A3B 2000 1350 600 230150 Cubicle A3B+A2 2000 1350 600 370175 Cubicle A3B 2000 1350 600 400200 Cubicle A3B 2000 1350 600 430

    225 Cubicle A3B 2000 1350 600 450250 Cubicle A3B 2000 1350 600 470275 Cubicle A3B 2000 1350 600 490300 Cubicle A3B 2000 1350 600 510350 Cubicle A4B 2000 2150 600 590375 Cubicle A4B 2000 2150 600 610400 Cubicle A4B 2000 2150 600 630450 Cubicle A4B 2000 2150 600 670500 Cubicle A4B 2000 2150 600 710550 Cubicle A4B 2000 2150 600 750600 Cubicle A4B 2000 2150 600 790700 Cubicles A4B+A3B 2000 3500 600 1140800 Cubicles A4B+A3B 2000 3500 600 1220900 Cubicles A4B+A3B 2000 3500 600 13201000 Cubicles A4B+A4B 2000 4300 600 14201100 Cubicles A4B+A4B 2000 4300 600 15001200 Cubicles A4B+A4B 2000 4300 600 1580

    4.3(215Hz)

    12 Cubicle A2 2000 1350 600 17025 Cubicle A2 2000 1350 600 18037 Cubicle A2 2000 1350 600 19050 Cubicle A2 2000 1350 600 20062 Cubicle A2 2000 1350 600 21575 3x25 Cubicle A2 2000 1350 600 225

    6x12.5 Cubicle A3 2000 1350 600 270100 4x25 Cubicle A2 2000 1350 600 245

    8x12.5 Cubicle A3 2000 1350 600 290125 Cubicle A2 2000 1350 600 265137 Cubicle A3 2000 1350 600 320150 Cubicle A3+A2 2000 1350 600 370175 Cubicle A3 2000 1350 600 400200 Cubicle A3 2000 1350 600 430225 Cubicle A3 2000 1350 600 450250 Cubicle A3 2000 1350 600 470275 Cubicle A3 2000 1350 600 490300 Cubicle A3 2000 1350 600 510350 Cubicle A4 2000 2150 600 590375 Cubicle A4 2000 2150 600 610400 Cubicle A4 2000 2150 600 630450 Cubicle A4 2000 2150 600 670500 Cubicle A4 2000 2150 600 710550 Cubicle A4 2000 2150 600 750600 Cubicle A4 2000 2150 600 790700 Cubicles A4B+A3B 2000 3500 600 1140800 Cubicles A4B+A3B 2000 3500 600 1220900 Cubicles A4B+A3B 2000 3500 600 13201000 Cubicles A4B+A4B 2000 4300 600 14201100 Cubicles A4B+A4B 2000 4300 600 15001200 Cubicles A4B+A4B 2000 4300 600 1580

    Cubicle A3B with incoming circuit breaker.

    D B 1 1 0 6 3 6

    _ 1

    Cubicle A4B with incoming circuit breaker.

    D B 1 1 0 6 3 5