SÜLEYMAN DEMİREL ÜNİVERSİTESİ MAKİNE MÜHENDİSLİĞİ BÖLÜMÜ HİDROLİK BASMAÇEKME DENEY CİHAZI HİDROLİK GÜÇ ÜNİTESİ DEVREYE ALMA KLAVUZU

Basma Çekme Deney Cihazı

Embed Size (px)

Citation preview

SLEYMANDEMRELNVERSTESMAKNE MHENDSLBLM HDROLKBASMAEKMEDENEYCHAZIHDROLK GNTES DEVREYEALMAKLAVUZU

A- TEKNK ZELLKLERSeri No : SU-11-069 Model : 2011 Debi : 1 cc Basn : 10-130 bar oransal ayarlanabilir Motor Gc : 0,37 kw Motor Devri : 1450 rpm Motor Voltaj : 380 Volt Bobin Voltaj : 24V DC alma Scakl : 5-60 C

B- ALIMA PRENSBSistem 0,37 kw 1450 rpm deerlerindeki motorun 1cc pompay tahrik etmesi ile yaklak 1,5 lt/dk debi retir. retilen debi 10 micron basn filtresinden geerek filtre edilir. 2.3 no lu valf retilen debiyi enerjisiz konumda iken by-pass ederek tanka gnderir. Sistem hareket ettirilmek istendii zaman yn valfinin yukar veya aa pozisyonu enerjilendirilir. Oransal basn emniyet valfine 0-10 volt kontrol voltaj gnderilerek sistem istenilen basnca ayarlanr. Oransal hz ayar valfine 0-10 volt kontrol voltaj gnderilerek sistem istenilen hz deerlerine ayarlanr. Sistemin ulaabilecei limit deerler aadaki gibidir. 50mm Hidrolik silindir, 1cc pompa ve 0,37 kw iin; Max Hz: 12mm/sn Max Kuvvet: 2550 kg Max Basn : 130 bar

C- CHAZIN DEVREYE ALINMASI1- Hidrolik g nitesi ya tankn ya seviye gstergesinin krmz izgisine kadar doldurunuz. 2- Elektrik motoru 380 volt AC balantsnn, yn kontrol valfi 24v DC balantsnn, oransal basn emniyet ve hz ayar valflerinin 24v DC besleme ve 0-10 volt DC kontrol voltaj balantlarnn kart devrelerine uygun olup olmadn ve doruluunu kontrol ediniz. 3- Elektrik motoru faz balantlarnn dn ynne uygun ekilde balandndan emin olunuz. 4- Hidrolik Silindirin ase zerinde tespit cvatalar sklm bir vaziyette sabitlendiinden emin olunuz. 5- Yukardaki kontroller yapldktan sonra cihaz yukarda belirtilen alma prensibine gre altrlabilir pozisyona gelecektir.

D- CHAZIN BAKIMI1- Ya tank zerinde iine debilecek ekilde yabanc parack olmamasna ve minimum ya seviyesine dikkat ediniz. 2- 6 aylk periyotlarda ya tank kapaklarn aarak ya boaltp tank ii ve emi filtreleri temizlii yapnz. 3- 1 yllk periyotlarda basn filtresi elemann yenisi ile deitiriniz. 4- Her yl sorun olsun olmasn elektrikli yn valflerinin oringlerini kontrol ederek deformasyon durumunda yenisi ile deiimini yapnz. 5- Pano kapa ve hidrolik depo kapann kapal durumda olmasna dikkat ediniz. 6- Arza durumunda Simya Hidrolik Ltd. ti. Servis Birimine mracaat ediniz.

Simya Hidrolik Pnmatik Ltd. ti. Fevzi akmak Mah. 10736. Sok. No:16 MODESA Karatay / KONYA Tel: 0 332 346 45 55 Fax: 0 332 346 45 58 www.simyahidrolik.com [email protected]

Malzeme Listesi Bill Of Materials

Mteri Ad / Customer Name S.D.. MAKNE MHENDSL BLMSipari Tar. / Order Date Teklif No / Quotation No Mteri Ref. / Customer Ref. Proje Sor. / Responsible Per. Teslim Haftas/Delivery Week Rev. / Rev. a Tarih / Date Revizyon Aklama / Revision Description

Proje Ad / Project Name BASMA DENEY CHAZI HDROLK G NTESDevre ema No / Circuit Diag. No

ST-0198-11 Mak. Mh. smail AHN

Montaj Resim No / Ass. Dwg. No Komponent No / Comp. List No Sipari Miktar / Order Quantity Hazrlayan / Prepared By

1 Mak. Mh. Kemalettin BACIOnay / Checked By

Poz. Pos.

Ident Numaras Ident Number

Malzeme Kodu / Material Code

Malzeme Ad / Tanm Material Name / Description

Marka Supplier

Adet Qty.

Rev.

Tek. Poz. Tec. Pos.

010 020 030 040 050 060 070 080 090 100 110 120 130 140 150 160 170 180 190 200 R928033536 SB-11-018 R901000847 R900702060 R900552009 R900934891 R901080965 63x160 BAR SGD 76 0510112003 EF 15

Gr.

20 lt MN 76 MM DERECEL HY-ZAHNRADPUMPE 15 lt DK 24 0,37 Kw 0K 160 350 LEN 040 VALF PLEYT DBET-61/315G24K4V VT-MSPA1-1X/VO/O 4WE 6 G6X/EG24N9K4/V 2FRE68-2X/2LK4RV VT-MRPA1-150-1X/VO/O ALTTAN IKILI GLSERNL HCD 250 C50/28-200 NTE NTE

YA TANKI DEPO KAPAI YA SEVYE GSTERGES DL POMPA EM FLTRES ELEKTRK MOTORU KAMPANA BASIN FLTRES HDROLK KONTROL BLOU ORANSAL BASIN EMN. VALF OR. BASIN EMN. VALF KARTI YN KONTROL VALF ORANSAL HIZ AYAR VALF OR. HIZ AYAR VALF KARTI MANOMETRE SLNDR BALANTI ELEMANLARI MONTAJ VE CLK

SMYA EMS EMS REXROTH EMS VOLT EMS REXROTH SMYA REXROTH REXROTH REXROTH REXROTH REXROTH PAKKENS SMYA CAST SMYA

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

LENM ELASTK DL KAPLN EMS

1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2,0 2,1 2,2 2,3 2,4 2,5 2,5 2,6 3,0 4,0

Proportional flow control valve, 2-way version

RE 29188/02.07 Replaces: 02.06

/2

Type 2FRE 6

Size 6 Component series 2X Maximum operating pressure 20 bar Maximum flow 25 l/minH639_d

Table of contentsContents Features Ordering code Standard types Symbols Function, section Technical data Electrical connection, cable sockets Characteristic curves Unit dimensions Page 2 2 3 4 5, 6 7 8, 9 0,

Features Valve with pressure compensator for the pressure-compensated control of a flow Actuation by means of proportional solenoid For subplate mounting: Position of ports to ISO 440-03-02-0-94 Subplates according to data sheet RE 45052 (separate order), see page 0 With electrical closed-loop position control of the metering orifice The position transducer coil can be axially shifted, which simplifies zero point balancing of the metering orifice (electrical-hydraulic) without the need for intervening into the control electronics Low manufacturing tolerances of the valve and the electrical amplifier types VT-VRPA-50-X (analogue) and amplifier module types VT-MRPA-50-X (analogue), separate order, see page 6 Flow control in both directions due to rectifier sandwich plate

Information on available spare parts: www.boschrexroth.com/spc

2/2

Bosch Rexroth AG

Hydraulics

2FRE 6

RE 29188/02.07

Ordering code: Proportional flow control valve 2FRESize 6 =6 V= R= M= K4 = = 1L = 2L = 8L = 3Q = 6Q = 10Q = 16Q = 25Q = 2QE

6

2X

K4

V

*Further details in clear text FKM seals, suitable for mineral oil (HL, HLP) to DIN 5524 With check valve Without check valve

With external closing of the pressure compensator =A (suppression of start-up jump) Without external closing of the pressure compensator = B Component series 20 to 29 = 2X (20 to 29: unchanged installation and connection dimensions) Nominal flow A B / Flow characteristics Linear: up to l/min up to 2 l/min up to 8 l/min Progressive: up to 3 l/min up to 6 l/min up to 0 l/min up to 6 l/min up to 25 l/min Progressiv with rapid speed Fine control range up to 2 l/min

Electrical connection Without cable socket with component socket to DIN EN 7530-803-A for proportional solenoid and GSA20 for position transducer Cable sockets separate order see page 7

Standard typesType 2FRE 6 B-2X/LK4RV 2FRE 6 B-2X/8LK4RV 2FRE 6 B-2X/0QK4RV 2FRE 6 B-2X/25QK4RV 2FRE 6 B-2X/2QEK4RV Material number R900947600 R900934070 R900949563 R90093787 R90095450

Ordering code: Rectifier sandwich plate Z4SSize 6 =6

6 1X V

*Further details in clear text

Component series 0 to 9 = 1X (0 to 9: unchanged installation and connection dimensions) FKM seals, suitable for mineral oil (HL, HLP) to DIN 5524 Type Z4S 6-X/V Material number R900489356 =V

Attention! Rectifier sandwich plate type Z4S 6-X/V can not be used in conjunction with a proportional flow control valve of type 2FRE 6 A-2X/ (with external closing of the pressure compensator).

RE 29188/02.07

2FRE 6

Hydraulics Bosch Rexroth AG

3/2

SymbolsProportional flow control valve (simplified, detailed) Type 2FRE 6 B-2X/MV Simplified Type 2FRE 6 B-2X/RV Type 2FRE 6 A-2X/MV Type 2FRE 6 A-2X/RV

Rectifier sandwich plate ( = component side, 2 = plate side) Type Z4S 6-X/V 1

Detailed

P

A

2 B

T

4/2

Bosch Rexroth AG

Hydraulics

2FRE 6

RE 29188/02.07

Function, sectionProportional flow control valves of type 2FRE feature a 2way function. They can control a flow, which is determined by an electrical command value, with pressure and temperature compensation. They basically consist of housing (), proportional solenoid with inductive position transducer (2), metering orifice (3), pressure compensator (4) and optional check valve (5). Proportional flow control valve type 2FRE 6 B-2X/.K4RV (without external closing, with check valve) The setting of the flow is determined by the setting (0 to 00 %) on the command value potentiometer. The selected command value causes metering orifice (3) to be adjusted via the amplifier and the proportional solenoid. The inductive position transducer senses the position of metering orifice (3). Any deviations from the command value are corrected by the closed-loop position control. Pressure compensator (4) keeps the pressure differential across metering orifice (3) always at a constant value. This ensures load-compensation of the flow. The low temperature drift is a result of the favourable design of the metering orifice. At a command value of 0 % the metering orifice is closed. In the event of a power failure or cable break on the inductive position transducer, the metering orifice closes. Starting from a 0 % command value, a jump-free start-up is possible. The metering orifice can be opened and closed with a delay provided by two ramps in the electrical amplifier. Check valve (5) allows the free return flow from B to A. The supply and return flow to and from the actuator can be controlled with the help of an additional rectifier sandwich plate of type Z4S 6 under the proportional flow control valve. Proportional flow control valve type 2FRE 6 A-2X/.K4MV (with external closing, without check valve) In principle, the function of this valve is the same as that of valve type 2FRE 6 B-2X/.K4RV. To suppress the start-up jump when metering orifice (3) is open (command value > 0 %), closing of pressure compensator (4) is provided via port P (6). There is no internal connection between port A and pressure compensator (4). The pressure in P upstream of directional valve (8) acts on pressure compensator (4) and holds it in the closed position against the force of spring (7). When directional valve (8) is switched from P to B, pressure compensator (4) moves from the closed position to the control position, thus preventing a start-up jump.

2

5 3 1 4

AType 2FRE 6 B-2X/.K4RV

B

3 7 4

8A A B

G B P

Actuator

6 A B PDse

P T

Type 2FRE 6 A-2X/.K4MV

RE 29188/02.07

2FRE 6

Hydraulics Bosch Rexroth AG

5/2

Technical data (for applications outside these parametes, please consult us!)GeneralWeight Proportional flow control valve Rectifier sandwich plate Installation orientation Storage temperature range Ambient temperature range C C kg kg ,8 0,9 Optional 20 to +80 20 to +50oil

Hydraulisch proportional flow control valve (measured with HLP46 and atMax. operating pressure in port A Version Max. flow Min. flow up to 00 bar up to 20 bar Max. leakage flow at 0 % command value p A B (measured at = 4 mm2/s and = 50 C) Minimum pressure differential Pressure differential with free return flow B A Pressure/flow relationship: Inlet/outlet pressure Dependence upon temperature Temperature drift, hydraulic and electrical Hydraulics fluid Max. permissible degree of contamination of the hydraulic fluid cleanliness class to ISO 4406 (c) Hydraulic fluid temperature range Viscosity range Hysteresis Repeatability Manufacturing tolerances Valve 2FRE 6 Amplifier VT-VRPA-50 (analogue) C mm2/s % % 50 bar 00 bar 20 bar l/min cm3/min cm3/min cm3/min cm3/min cm3/min bar bar up to 20 1L 25 25 4 5 7 6 to 0 2L 2 25 25 4 5 7

= 40 C 5 C) 3Q 3 5 25 4 5 7 6Q 6 25 25 4 5 7 10Q 0 50 50 6 8 2 16Q 6 70 70 7 0 5 25Q 25 00 00 0 5 22 2QE 25 5 25 4 5 7

8L 8 50 50 6 8 2

see characteristic curve on page 9 see characteristic curve on page 9 see characteristic curve on page 9 Mineral oil (HL, HLP) to DIN 5524 Further hydraulic fluids on enquiry! Class 20/8/5 ) 20 to +80 5 to 380 < of qVmax < of qVmax 3 % at 33 % command value 5 % at 00 % command value Amplifier must be matched to the valve 2)

Amplifier module VT-MRPA-50 (analogue) Amplifier must be matched to the valve 2)

Hydraulic rectifier sandwich plateOperating pressure Cracking pressure Nominal flow)

bar bar l/min

up to 20 0,7 252)

The cleanliness classes specified for components must be adhered to in hydraulic systems. Effective filtration prevents malfunction and, at the same time, prolongs the service life of components. For the selection of filters, see data sheets RE 50070, RE 50076, RE 5008, RE 0086 and RE 50088.

Due to tolerances of the oscillator frequency (position transducer supply), amplifiers are subject to tolerances. When installing new systems or replacing an amplifier, the amplifier settings may have to be adjusted.

6/2

Bosch Rexroth AG

Hydraulics

2FRE 6

RE 29188/02.07

Technical data (for applications outside these parametes, please consult us!)Electrical proportional solenoidType of voltage Coil resistance Cold value at 20 C Max. hot value Duty cycle Max. current per solenoid Electrical connection % A DC 5.4 8.2 00 .5 With component plug to DIN EN 7530-803-A Cable socket to DIN EN 7530-803-A ) Type of protection to EN 60529 IP 65 2) with cable socket mounted and locked

Electrical inductive position transducerCoil resistance Total resistance of coil between and 2 3,5 2 and 45,5 and 3,5 at 20 C (see page 7) Electrical connection

With component plug GSA20 Cable socket GM209N (Pg9) )

Type of protection to EN 60529 Inductance Oscillator frequency Electrical position measuring system Nominal stroke mm mH kHz

IP 65 2) with cable socket mounted and locked 6 to 8 2.5 Differential throttle 3.5

Control electronics (separate order)Associated amplifier in Euro-card format Associated amplifier module Type VT-VRPA-50-X (analogue) to data sheet RE 308 Type VT-MRPA-50-X (analogue) to data sheet RE 3022

) 2)

Separate order, see page 7 Due to the surface temperatures of solenoid coils, observe European standards DIN EN 563 and DIN EN 982!

RE 29188/02.07

2FRE 6

Hydraulics Bosch Rexroth AG

7/2

Electrical connection, cable sockets (nominal dimensions in mm)Proportional solenoid Connection to component plug Connection to cable socket

PE PE 1 2 1 2

to amplifier

Cable socket to DIN EN 7530-803-A Separate order stating material no. R901017011 (plastic version) 27,5 27,5 53

36

22,5 30 Seal material: NBR 4,5 ... 10 Shield 21 ~51 28,6 34 18 4,5 ... 7,0 Seal material: NBR

30

Cable socket Pg 9 Separate order stating material no. R900013674 (plastic version)

20,8

8/2

Bosch Rexroth AG

Hydraulics

2FRE 6

RE 29188/02.07

Characteristic curves (measured with HLP46 and at oil = 40 C 5 C)Dependence of flow on command value voltage (flow control from A B); pnom = 50 bar

Flow in l/min

Command value voltage in %

Flow in l/min

Command value voltage in %

Flow in l/min Command value voltage in % 80 100 0 20 Time in ms 40 60 80 100

Transient function at stepped command value change ; pnom = 00 bar; valve type 25Q 100 90 80 Stroke in % 70 60 50 40 30 20 10 0 20 40 60

Frequency response characteristic curves; pnom = 00 bar; valve type 25Q 1 0 1 2 Gain in dB 3 4 5 6 7 8 9 0,1 0,5 1 2 3 Frequency in Hz 4 5 6 8 10 15 20 Curve Command value amplitude 45 to 55 % (50 % 5 %) Curve Command value amplitude 0 to 100 % (50 % 50 %)

150 135 120 Phase angle in 105 90 75 60 45 30 15 0

RE 29188/02.07

2FRE 6

Hydraulics Bosch Rexroth AG

9/2

Characteristic curves (measured with HLP46 and atProportional flow control valve Pressure/flow relationship

oil

= 40 C 5 C)

Flow in l/min

Inlet pressure pnom(A) in bar (pressure in B ~ 0 bar) Dependence on temperature (flow characteristic 25Q largest deviation) at p = 30 bar 2600 2500 Flow in cm3/min 2400 2300 450 120 100 80 0 10 20 30 40 50 60 70

Flow in l/min

Outlet pressure pA(B) in bar (pressure in A 20 bar) Pressure differential across check valve B A Orifice closed Pressure differential in bar 7 6 5 4 3 2 1 0 4 8 12 16 20 24

Flow in l/min

Fluid and valve temperature in C Rectifier sandwich plate p-qV characteristic curve 6 Pressure differential in bar 5 4 3 2 1 0 5 10 15 20 25

Flow in l/min

10/2

Bosch Rexroth AG

Hydraulics

2FRE 6

RE 29188/02.07

Unit dimensions: Proportional flow control valve (nominal dimensions in mm) 3.2 4 215

3.1227 179

515 114

167

622

48

"Y"A P B

10 5,5

45 0,01/100mm Rzmax 4 Required surface quality of the valve contact face 63

10

60 P A B 12,6 8

88 A B

11

7

12,6 3

F1 47 F4 A P

B F2 G F3

Detail Y Type 2FRE 6 A 1 Valve housing 2 Proportional solenoid with indutive position transducer 3.1 Cable socket for proportional solenoid, separate order, see page 7 3.2 Cable socket for proportional solenoid, separate order, see page 7 4 Space required to remove cable socket 5 Nameplate 6 Identical seal rings for ports A, B, P and blind hole 7 Port A 8 Port B 9 Blind hole 2.6 mm 10 Machined valve contact face, position of ports to ISO 440(with locating bore) (Code: 440-03-02-0-94 explanation to ISO 5783)

9

Detail Y Type 2FRE 6 B Tolerances to:

10

General tolerances to ISO 2768-mK

Subplates to data sheet RE 45052 and valve fixing screws must be ordered separately. Subplates: G34/0 (G/4) G342/0 (G3/8) G502/0 (G/2)

Valve fixing screws (separate order) The following valve fixing screws are recommended: 4 socket head cap screws to ISO 4762 - M5x30 - 10.9-flZn240h-L (friction coefficient 0.09 to 0.4 to VDA 235-0); tightening torque MT = 7 Nm 0%, material no. R913000316 4 socket head cap screws to ISO 4762 - M5x30 - 10.9 (friction coefficient 0.08 to 0.6 to VDI 2230 tempering, black) tightening torque MT = 8. Nm 0%

RE 29188/02.07

2FRE 6

Hydraulics Bosch Rexroth AG

11/2

Unit dimensions: Rectifier sandwich plate (nominal dimensions in mm) A1 B1 140 (227) 12,5; 1,3

B28

11 12

A1 B140

6 13

A1

B160

0,01/100mm Rzmax 4 Required surface quality of valve contact face

1 Valve housing 6 Identical seal rings for ports A2 and B2 11 Rectifier sandwich plate 12 Subplate (separate order), see page 0 13 Valve contact face for 2FRE 6 Attention! Rectifier sandwich plate type Z4S 6-X/V can not be used in conjunction with a proportional flow control valve of type 2FRE 6 A-2X/ (with external closing of the pressure compensator).

(max. 35)

Tolerances to:

General tolerances ISO 2768-mK

Valve fixing screws (separate order) The following valve fixing screws are recommended: 4 socket head cap screws to ISO 4762 - M5x70 - 10.9-flZn-240h-L (friction coefficient 0.09 to 0.4 to VDA 235-0); tightening torque MT = 7 Nm 0%, material no. R93000325 4 socket head cap screws to ISO 4762 - M5x70 - 10.9 (friction coefficient 0.08 to 0.6 to VDI 2230 tempering, black) tightening torque MT = 8. Nm 0%

12/2

Bosch Rexroth AG

Hydraulics

2FRE 6

RE 29188/02.07

Notes

Bosch Rexroth AG Hydraulics Zum Eisengieer 9786 Lohr am Main, Germany Phone +49 (0) 93 52 / 8-0 Fax +49 (0) 93 52 / 8-23 58 [email protected] www.boschrexroth.de

This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. Without their consent it may not be reproduced or given to third parties. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

Analog amplifier module

RE 30221/02.09 Replaces: 06.08

1/8

Type VT-MRPA1-...

Series 1XH7076

Table of contentsContents Features Ordering details Functional description Block circuit diagram / connection allocation Technical data Terminal allocation Unit dimensions Engineering notes / maintenance guidelines / additional information Setting recommendations Page 1 2 2 3 4 5 5 6 6

Features Suitable for controlling direct operated proportional relief valves with electrical position feedback (type DBETR-1X) or for proportional flow control valves with electrical position feedback (type 2FRE...) Command value input +10 V (differential input) Ramp generator with separately adjustable ramp times up/down Zero point potentiometer Amplitude attenuation Enable input Reverse polarity protection for the power supply Power supply with a DC/DC converter without a raised zero point Cable break recognition in the position transducer branch LEDindicators: Operational(green) Enable(yellow)

Measuringsocketsfor: Commandvaluew Actualvalvex Ramptimest Suitable power supply: Type VT-NE30-2X, see RE 29929 Compact power supply 115/230 VAC 24 VDC, 108 W Attention:

When replacing a VT 11025, VT 11033 and VT 11034 the changed terminal allocation of position transducer conections has to be taken into account!

2/8

Bosch Rexroth AG

Hydraulics

VT-MRPA1-...

RE 30221/02.09

Ordering details VT-MRPA1Analog amplifier of modular design For controlling a DBETR-1X valve For controlling a 2FRE6-2X valve For controlling a 2FRE10 and 16-4X valve Series 10 to 19 (10 to 19: unchanged technical data and pinout) = 100 = 150 = 151 = 1X

1X V0

0

* Furtherdetailsincleartext Basic version Basic version

Functional descriptionGeneral These amplifier modules can be snapped onto top hat rails to EN 60715. The electrical connections are are established by means of screw terminals. The modules are operated using 24 VDC. Power supply unit [1] The amplifier modules comprise a power supply unit with an inrush current limiter. It provides all the internally required positive and negative supply voltages. The inrush current limiter prevents high inrush current peaks. Command value preselection The internal command value signal is generated from the sum[3]oftheexternalcommandvaluesignalappliedtodifferential input [2] and the zero point offset (zero point potentiometer Zw). A positive command value results in a current increase in the solenoid and, thereby an increase in pressure at the valve. Enable function [11] The enable function is used to enable the current output stages and to pass the internal command value signal on to the ramp generator. A LED on the front panel indicates the enable signal. When the enable is activated, the internal command value (an applied optional command value) changes according to the set ramp time. As a result of this, the valve does not open suddenly when activated. Ramp generator [4] The ramp generator limits the gradient of the control variable. Duetotheamplitudeattenuator,theramptimeisnotextended or shortened. Notes on the adjustment and measurement of the ramp time: Actual ramp time (20 %) Ut in V t in ms 1 0.5 0.3 333 Valueatmeasuringsockett Ut in V 5 20 3 33 2 50 0.02 5000 t in ms 0.05 100 V ms Ut Amplitude attenuation [5] The amplitude attenuator Gw can be used to adjust the maximumvalue,withintherangeof0-100%,tothehydraulic requirements. Amplitude limiter [6] The internal command value is limited to 0 % and 110 %. Oscillator [9] The oscillator generates the control signal for the inductive position transducer. Demodulator [10] The demodulator uses the position transducer signal to provide the actual value signal of the valve spool position: +100%=+10Vatmeasuringsocketx. Controller for the valve spool position [7] The position controller is used to minimize the valve hysteresis and is optimised to meet the individual valves requirements. Current output stages [8] The current output stage generates the clocked solenoid current for the proportional valve. The solenoid current is limited toapprox.1.85A.Theoutputstageoutputsareshort-circuitproof. The output stages are de-energized in the case of an internal fault signal or missing enable. Fault detection [14] The position transducer cable is monitored for cable break and short circuits and the output stage for overcurrent. [ ] = Cross-reference to the block circuit diagram on page 3

0.2

0.1

0.03 3333

100 200

500 1000 2000 t=

The following is valid: Example: Measured Results in

Ut = 5 V 100 V ms t = = 20 ms 5V

RE 30221/02.09

Differential input (Ucomm)w

t t>

4

u

Gmax

VT-MRPA1-...

12

Enable

3

11

& PID7 14UB M0 10

9 =11

Block circuit diagram / connection allocation

x

10 =Gx Zx 6

2 1

13

+ UB 1

DCAttention:

Operating voltage

12

0V

2

DC1

Hydraulics

L0

+ 15 V + 10 V M0 10 V 15 V

When replacing a VT 11025, VT 11033 and VT 11034 the changed terminal allocation of position transducer connections has to be taken into account. Pins 6 and 12 are exchanged.1 2 3 4 5 6 7 Power supply unit Differential amplifier Command value summator Ramp generator Amplitude attenuator Amplitude limiter Controller for valve spool position 8 9 10 11 12 13 14 Current output stage Oscillator Demodulator Enable function Proportional valve Inductive position transducer Fault detection

Zw = = = = = Enable Operational Actual value Command value w x

=

Zero point com. value

Gx

Actual value sensitivity

Zx

=

Zero point actual value

t

=

Ramp time down

Bosch Rexroth AG

Gw

=

Amplitude attenuator

3/8

4/8

Bosch Rexroth AG

Hydraulics

VT-MRPA1-...

RE 30221/02.09

Technical data (for applications outside these parameters, please consult us!)Operating voltage Operating range: Upper limit value Lower limit value Power consumption Current consumption Fuse UB 24 VDC +40 % 20 % uB(t)max 35 V uB(t)min 18 V PS 100k U 0 to 6.5 V; Re>100k 10 % 10 % 20 ms to 5 s 0 % to 110 % (valid for setting the zero point = 0 %)

RE 30221/02.09

VT-MRPA1-...

Hydraulics

Bosch Rexroth AG

5/8

Terminal allocationConnection cable (recommendation): 2-core cable, single screen, cross-section 1.5 mm2

Operating voltage

+UB 0V UF IN +IN 1

1 2 3 4 5 6

7 8 9 10 11 12 2

Solenoid

Enable

Free

Differential input Position transducer, primary

Position transducer control

3-core cable, single screen, max.cross-section1.5mm2

Attention: The position transducer connection has changed when compared to the VT 11025, VT 11033 and VT 11034!

Unit dimensions (dimensions in mm)Top hat rail TH 35-7,5 to EN 60715 7 8 9 10 11 12REXROTHVT-MRPA1-100

LED-indicators: Operational (green) Enable (yellow) Potentiometer: Gw Gx Zw Zx t< t> Amplitude attenuator for positive com. values Position transducer sensitivity (pre-set) Command value zero point Actual value zero point Ramp time for increasing command values Ramp time for decreasing command values Ramp time up Ramp time down Actual value Command value Measuring zero

Gw Zw Gx Zx t< t>t< t> x w

79

1 2 3 4 5 6 85,5 40

Measuring sockets: t< t> x w

6/8

Bosch Rexroth AG

Hydraulics

VT-MRPA1-...

RE 30221/02.09

Engineering notes / maintenance guidelines / additional informationThe amplifier module may only be wired when disconnected from the power supply! Do not lay cables in the vicinity of power cables! Do not use free-wheeling diodes in solenoid cables! The distance to antenna cables, radio devices and radar systems must be at least 1 meter! Always shield command value and position transducer cables; connect the shield to protective earth (PE) on the module side! In individual cases (e.g. PE subject to strong interference), it may be required to connect the shield of the position transducer cable directly to the LO of the amplifier module; leave the other end open (risk of earth loops). Recommendation: Also shield solenoid cables! For solenoid cables up to 50 m long, use cable type LiYCY 1.5 mm2! In case of longer lengths, please consult us!

Do not connect terminal of the position transducer to PE Use relays with gold-plated contacts for passing on command values (small voltages, small currents)! Use only instruments Ri>100kfortakingmeasurementsonthemodule. Inthecaseofstronglyfluctuatingoperatingvoltages,itmayberequiredinindividualcasestouseanexternalsmoothing capacitor with a capacitance of at least 2200 F. Recommendation: Capacitor module VT 11073 (see RE 29750); sufficient for up to 3 amplifier modules Attention: When replacing a VT 11025, VT 11033, VT 11034 the changed terminal allocation of position transducer connec tionshastobetakenintoaccount.Pins6and12areexchanged.

Setting recommendationsThe system-specific circuits must be provided. Signal Com. value zero point Setting MRPA1 Apply the enable signal Settheexternallyappliedcommandvaluetozero Set the internal command value to zero using the zero point potentiometer Zw and check at measuring socket w Act. value zero point Set enable signal to OFF or disconnect the solenoid plug (the valve moves to its mechanical limit stop) When making any adjustments, pay attention to the polarity of the measuring instrument measuring sockets! Ramp times Adjust the ramp time according to the formula or table (see functional description of the ramp generator) and check this at measuring sockets t>andt

I>F

UCommand value +10 V 6

9

10 W 16 i

U4 5

GwF

1 2 3 4 5 6

Fuse Suppressor diode Power supply unit Command value input Ramp generator Zero point potentiometer

7 8 9

Up ramp potentiometer Down ramp potentiometer Potentiometer Imax

13 Schmitt trigger 14 Output stage 15 Fault recognition 16 Measuring socket F on front panel

10 Characteristic curve generator 11 Current regulator 12 Clock pulse generator

Terminal assignment / drawingTerminal assignment Terminal 2 3 4 5 6 +UB Ground Ucomm Solenoid + Solenoid +Ucomm Gw Zw t< t> wI Drawing

4 5 6

P

Potentiometers:

Gw Pressure command value Zw t Zero point Ramp time up Ramp time down Pressure command value Actual current value Measurement zero

RexrothVT-MSPA1-1

ESockets:

w I "

1 2 3

4/6

Bosch Rexroth AG

Hydraulics

VT-MSPA1-1

RE 30223/07.07

Technical data (for applications outside these parameters, please consult us!)VT-MSPA1-1 Operating voltage Operating range:: Upper limit value Lower limit value Power consumption Current consumption Fuse Inputs: Command value (differential input) Outputs: Solenoid current/resistance Frequency Adjustment ranges: GW: Solenoid current ZW: t >: t wI

1 2 3

85,5

25

6/6

Bosch Rexroth AG

Hydraulics

VT-MSPA1-1

RE 30223/07.07

Engineering / maintenance notes / supplementary information The amplifier module may only be wired when disconnected from the power supply! The distance to radio equipment must be sufficiently large (>> m)! Shield command value cables; do not install them in the vicinity of power cables; shield solenoid cables! Do not use free-wheeling diodes in solenoid cables! In the case of strongly fluctuating operating voltages, it may in some cases be required to install a smoothing capacitor having a capacitance of at least 2200 F. Recommendation: Capacitor module VT 073 (see RE 29750); sufficient for up to 3 amplifier modules.

Bosch Rexroth AG Hydraulics Zum Eisengieer 9786 Lohr am Main, Germany Phone +49 (0) 93 52 / 8-0 Fax +49 (0) 93 52 / 8-23 58 [email protected] www.boschrexroth.de

This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

Proportional pressure relief valve, direct operated, without/with integrated electronics (OBE)Types DBET and DBETE

RE 29162/07.08 Replaces: 05.06

1/14

Size 6 Component series 6X Maximum operating pressure 420 bar Maximum flow 2 l/min

HAD/6825

HAD/7240

Type DBET-6X/..

Type DBETE-6X/..

Table of contentsContent Features Ordering code Standard types Accessories (not included in the scope of supply) Symbols Function, section Technical data Electrical connection Integrated electronics (OBE) Characteristic curves Unit dimensions Page 1 2 2 2 3 4 5 and 6 7 and 8 8 9 to 11 12 and 13

Features Direct operated valve for limiting a system pressure Actuation by proportional solenoid Proportional solenoid with central thread and detachable coil For subplate mounting: Porting pattern to ISO 4401-03-02-0-05 Integrated electronics (OBE) on type DBETE: Lowmanufacturingtoleranceofcommandvalue/pressure characteristic curve External control electronics for type DBET Amplifiersofmodulardesign,Euro-cardformat,andas plug-in amplifiers Independentlyadjustableupanddownramp Fine-tuningofcommandvalue/pressurecharacteristic curve possible

Information on available spare parts: www.boschrexroth.com/spc

2/14

Bosch Rexroth AG

Hydraulics

DBET, DBETE

RE 29162/07.08

Ordering code DBETProportional pressure relief valve For external control electronics = No code With integrated electronics (OBE) =E Component series 60 to 69 (60 to 69: unchanged installation and connection dimensions) Max. pressure rating Up to 50 bar Up to 100 bar Up to 200 bar Up to 315 bar Up to 350 bar Up to 420 bar Internal pilot oil drain External pilot oil drain Supply voltage of integrated electronics (OBE) 24 V DC voltage = 6X V=

6X

G24

V

*Further details in clear text Seal material FKM seals suitableformineraloil(HL,HLP) to DIN 51524 Electronics interface Command value 0 to 10 V Command value 4 to 20 mA On DBET

= 50 = 100 = 200 = 315 = 350 = 420 = No code =Y = G24

A1 = F1 = No code =

K4 =

Electrical connection for DBET: Without mating connector, with component plug to DIN EN 175301-803 for DBETE: Without mating connector, with component plug to DIN EN 175201-804

K31 =

Standard typesType DBET Type DBET-6X/50G24K4V DBET-6X/100G24K4V DBET-6X/200G24K4V DBET-6X/315G24K4V DBET-6X/350G24K4V Material no. R901000842 R901000845 R901000846 R901000847 R901000848 Type DBETE-6X/50G24K31A1V DBETE-6X/100G24K31A1V DBETE-6X/200G24K31A1V DBETE-6X/315G24K31A1V DBETE-6X/350G24K31A1V Type DBETE Material no. R901029966 R901029967 R901029968 R901029969 R901029970

Accessories (not included in the scope of supply) Subplates NG6 to data sheet RE 45052 G341/01(G1/4),Materialno.R900424447 G341/60(G3/8),Materialno.R901027119 External control for type DBET: AnalogamplifierVT-MSPA1-1-1X/V0/ofmodular design to data sheet RE 30223 DigitalamplifierVT-VSPD-1-2X/V0/.-0-1 in Euro-card format to data sheet RE 30523 AnalogamplifierVT-VSPA1-2-1X/V0/ in Euro-card format to data sheet RE 30115 AnalogamplifierVT-SSPA1-1-1X/V0/0-24asplug-in amplifier to data sheet RE 30265 Restrictions: No linearization of the command value/pressure characteristic curve, higher hysteresis and range of inversion Mating connectors (for details, see page 7) ForDBET:toDINEN175301-803, Material no. R901017011 ForDBETE:toDINEN175201-804, Material no. R900021267 or R900223890

RE 29162/07.08

DBET, DBETE

Hydraulics

Bosch Rexroth AG

3/14

SymbolsFor external control electronics (type DBET) Internal pilot oil drain T With integrated electronics (type DBETE) Internal pilot oil drain T

P External pilot oil drain (Y) T Y

P External pilot oil drain (Y) T Y

P

P

4/14

Bosch Rexroth AG

Hydraulics

DBET, DBETE

RE 29162/07.08

Function, sectionAllgemeines Proportional pressure relief valves of type DBET are remote control valves of poppet design and are used to limit a system pressure. They are actuated by a proportional solenoid with central thread and detachable coil. The inner chamber of the solenoid is connected with port T or Y and is filled with hydraulic fluid. These valves can be used to infinitely vary the system pressure to be limited in dependence upon the electrical command value. The valves basically consist of housing (1), proportional solenoid (2), valve seat (3) and valve poppet (4). Basic principle Toadjustthesystempressure,acommandvalueisprovided to the control electronics. Depending on this command value, the electronics applies an electric current to the solenoid coil. The proportional solenoid converts the electric current into a mechanical force, which acts via armature plunger (5) to valve poppet (4). Valve poppet (4) is pressed on valve seat (3) and closes the connection between port P and T or Y. When the hydraulic force that acts on valve poppet (4) is equal to the magnetic force, the valve regulates the set pressure by lifting valve poppet (4) off valve seat (3) thus allowing hydraulic fluid to flow from port P to T or Y. With a zero command value the control electronics applies only a minimum control current to proportional solenoid (2), which results in the minimum pressure.

Type DBET Type DBET...Y External pilot oil drain

Type DBETE

Type DBETE with integrated electronics (OBE) In terms of function and design, these valves correspond to type DBET. In addition, housing (6) with the control electronics is provided on the proportional solenoid. The supply and command value voltage is applied to component plug (7). The command value/pressure characteristic curve is finetuned in the factory with low manufacturing tolerances. For further details on the control electronics, see pages 6 and 8.

RE 29162/07.08

DBET, DBETE

Hydraulics

Bosch Rexroth AG

5/14

Technical data (for applications outside these parameters, please consult us!)GeneralType Weight Installation position Storage temperature range Ambient temperature range C C 20 to +70 kg DBET 2.0 Optional 20 to +80 20 to +50 DBETE 2.15

Hydraulic (measuredwithHLP46;oil = 40 C 5 C )Type Maximum operating pres- Port P sure Maximum pressure setting Pressure rating 50 bar Pressure rating 100 bar Pressure rating 200 bar Pressure rating 315 bar Pressure rating 350 bar Pressure rating 420 bar Minimum pressure setting (with command value 0 V or 4 mA) Return flow pressure Maximum flow Hydraulic fluid Hydraulic fluid temperature range Viscosity range C mm2/s Port T or Y bar bar bar bar bar bar bar bar l/min DBET 420 50 100 200 315 350 420 See characteristic curves on page 11 Separately at zero pressure to tank 2 1) Mineraloil(HL,HLP)toDIN51524, further hydraulic fluids on request! 20 to +80 20 to 380, preferably 30 to 46 Class 20/18/15 2) < 4 of set max. pressure < 0.5 of set max. pressure < 0.5 of set max. pressure 3 of set max. pressure < 1.5 of set max. pressure 3) < 1.5 of set max. pressure DBETE

Permissible maximum degree of contamination of the hydraulic fluid - cleanliness class to ISO 4406(c) Hysteresis Range of inversion Response sensitivity Linearity(flow0.8l/min) Tolerance of command value/pressure characteristic curve referred to0.8l/min;increasing pressure At command value 20 % At command value 100 % % % % % %

% < 5 of set max. pressure 4)

Step response (Tu + Tg) 0 100 % and 100 % 0 Linevolume10k

0 to 1.6 V actual value (1 mV

Connected to solenoid and valve body

Mating connectors to DIN EN 175201-804, soldered contacts for cable cross-section 0.5 to 1.5 mm2 86

6,511

Plastic version, Material no. R900021267 (separate order)

27

B C D

A F E

Metal version, Material no. R900223890 separate order

28

B C 813,5 D

AF E

85

8/14

Bosch Rexroth AG

Hydraulics

DBET, DBETE

RE 29162/07.08

Electrical connectionConnection cable for type DBETE Min. supply voltage in V Recommendation: 6-wire, 0.75 or 1 mm2 plus protective earth conductor and shield Connect shield to PE only on the supply side Permissible max. length 100 m The minimum supply voltage of the power supply unit depends on the length of the supply cable (see diagram).

Lengthinm

Integrated electronics (OBE) of type DBETEFunction The electronics is supplied with voltage via connections A and B. The command value is applied to differential amplifier connections D and E. With the help of the characteristic curve generator, the commandvalue/solenoidcurrentcharacteristiccurveisadjusted to the valve so that non-linearities in the hydraulics are compensated for and a linear command value/pressure characteristic curve is obtained. The current regulator regulates the solenoid current independently of the solenoid coil resistance. Block circuit diagram The power stage of the electronics for controlling the proportional solenoid is a chopper amplifier with a clock frequency of ca. 180 Hz to 400 Hz. The output signal is pulse-widthmodulated (PWM). For testing the solenoid current, a voltage, which is proportional to the solenoid current, can be measured on the plug-in connector between Pin F(+) and Pin C(). 1 mV corresponds to a solenoid current of 1 mA.

24 VDC Supply GND Actual value reference potential Command value Command value reference potential Actual value

A B C D E F PE U UDifferential amplifier

DC DCChopper amplifier Solenoid

Characteristic curve generator

Current regulator

U U

=Oscillator

RE 29162/07.08

DBET, DBETE

Hydraulics

Bosch Rexroth AG

9/14

Characteristic curves(measuredwithHLP46,oil = 40 C 5 C)Pressure in port P in dependence on command value (flow = 0.8 l/min) 100 Pressure in port P in % 80 60 40 20 0 20 40 60 80 100 DBET1)

DBETE 100 Pressure in port P in % 80 60 40 20 0

20

With 20 % factory zero Command value in % point calibration

40 60 80 Command value in %

100

1)OnvalveDBET,thetolerancecanbeadjustedontheex-

ternal amplifier (for type and data sheet, see page 2) using command value attenuator potentiometer Gw. The digitalamplifiercanbesetbymeansofparameterLimit. Here, the control current according to the technical data must not be exceeded. In order that several valves can be matched to the same characteristic curve, at a command value of 100 %, the pressure must not be set higher than the maximum pressure setting.

10/14

Bosch Rexroth AG

Hydraulics

DBET, DBETE

RE 29162/07.08

Characteristic curves(measuredwithHLP46,oil = 40 C 5 C)Pressure in port P in dependence on flow 60 Pressure in port P in bar 50 40 30 20 10 0 0,4 0,8 1,2 Flow in l/min 1,6 1 2,0 3 2 Pressure rating 50 bar 5 Pressure in port P in bar 4 120 100 80 60 40 20 0 0,4 0,8 1,2 Flow in l/min 5 1,6 1 2,0 4 3 2 Pressure rating 100 bar 5

Pressure in port P in bar

5 4 3 2

Pressure in port P in bar

240 200 160 120 80 40 0

Pressure rating 200 bar

350 300 250 200 150 100 50 0

Pressure rating 315 bar 1)

Max. operating pressure 4 3 2

0,4

0,8 1,2 Flow in l/min

1,6

1 2,0

0,4

0,8 1,2 Flow in l/min

1,6

1 2,0

Pressure in port P in bar

Pressure in port P in bar

Pressure rating 350 bar 2) 5 350 300 250 200 150 100 50 0 0,4

Max. operating pressure 4 3 2

420 400 350 300 250 200 150 100 50 0

Pressure rating 420 bar 2) 5

Max. operating pressure 4 3 2

0,8 1,2 Flow in l/min

1,6

1 2,0

0,4

0,8 1,2 Flow in l/min

1,6

1 2,0

Valid for all pressure ratings: Curve 1 at 0 % command value Curve 2 at 25 % command value1)

With characteristic curve 5, the command value must not exceed the maximum flow of 1.4 l/min With characteristic curve 5, the command value must not exceed the maximum flow of 0.8 l/min

Curve 3 at 50 % command value Curve 4 at 75 % command value Curve 5 at 100 % command value 1;2) The characteristic curves were measured without backpressure in port T measured. (pT = 0 bar)

2)

RE 29162/07.08

DBET, DBETE

Hydraulics

Bosch Rexroth AG

11/14

Characteristic curves(measuredwithHLP46,oil = 40 C 5 C)Min. set pressure in port P at command value 0 V or 4 mA in dependence on flow Pressure rating 50 bar Pressure in port P in bar Pressure in port P in bar Pressure rating 100 bar

3,0 2,5 2,0 1,5 1,0 0,5 0

0,4

Flow in l/min Pressure rating 200 bar Pressure in port P in bar Pressure in port P in bar

0,8 1,2 Flow in l/min

1,6

2,0

Pressure rating 315 bar

Flow in l/min Pressure rating 350 bar Pressure in port P in bar Pressure in port P in bar

Flow in l/min Pressure rating 420 bar

Flow in l/min Note The characteristic curves were measured without backpressure in port T. (pT = 0 bar) Min.controlcurrent100mA (This current is obtained with command value 0 V or 4 mA!)

Flow in l/min

12/14

Bosch Rexroth AG

Hydraulics

DBET, DBETE

RE 29162/07.08

Unit dimensions: Type DBET (dimensions in mm) 5 6 894 1 25 G1/4

1

212+1

15

Y

12,9

37 44,5

147,5 10 5,5

56,5

T 47 2

7 3

T P9,3 28,3 40,5 45

T Y P9,7

F1 A F4

F2 T B P F3 G 59

9

0,01/100 Rzmax 4 Required surface quality of valve mounting face

47 10,5

8

1 2 3 4 5 6 7 8

Proportional solenoid Valve housing Nameplate Identical seal rings for ports P, T, A and B Mating connector to DIN EN 175301-803 Space required to remove mating connector Blind countersinks A and B On variant ..Y.. (external pilot oil drain) port Y is internally connected to port T! Port T is not plugged! 9 Machined valve mounting face, porting pattern to ISO 4401-03-02-0-05 Deviating from standard: A and B channels are not drilled Locatingpinnotincludedinthescopeofsupply

Valve mounting screws (not included in the scope of supply) 4 hexagon socket head cap screws ISO4762-M5X45-10.9-flZn-240h-L (Friction coefficient, total: 0.09-0.14 to VDA 235-101), MT = 7 Nm 10% Material no.: R913000140

RE 29162/07.08

DBET, DBETE

Hydraulics

Bosch Rexroth AG

13/14

Unit dimensions: Type DBETE (dimensions in mm) 615 91 60

3

114,5

2 7max. 200

91

25 G1/4

512,9

Y

37 44,5

12+1

1

147,5 10 5,5

56,5

47 2

T

8

10 T

T45

45

37

Y P9,7

P9,3 40,5 F1 A F4 Proportional solenoid Valve housing Integrated electronics (OBE) Identical seal rings for ports P, T, A and B Mating connector to DIN EN 175301-804 Space required to remove mating connector Cable mount Blind countersinks A and B On variant ..Y.. (external pilot oil drain) port Y is internally connected to port T! Port T is not plugged! 10 Nameplate 11 Block circuit diagram of integrated electronics (OBE) 12 Machined valve mounting face, porting pattern to ISO 4401-03-02-0-05 Deviating from standard: A and B channels not drilled Locatingpinnotincludedinthescopeofsupply 1 2 3 4 5 6 7 8 9 10,5 59 F2 T B P F3 G

8

1147

120,01/100 Rzmax 4 Required surface quality of valve mounting face

Valve mounting screws (not included in the scope of supply enthalten) 4 hexagon socket head cap screws ISO4762-M5X45-10.9-flZn-240h-L (Friction coefficient, total: 0.09-0.14 to VDA 235-101), MT = 7 Nm 10% Material no.: R913000140

14/14

Bosch Rexroth AG

Hydraulics

DBET, DBETE

RE 29162/07.08

Bosch Rexroth AG Hydraulics Zum Eisengieer 1 97816LohramMain,Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 [email protected] www.boschrexroth.de

This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does notreleasetheuserfromtheobligationofownjudgmentandverification.Itmustberememberedthatourproductsaresubjecttoanatural process of wear and aging.

RE 29162/07.08

DBET, DBETE

Hydraulics

Bosch Rexroth AG

15/14

Bosch Rexroth AG Hydraulics Zum Eisengieer 1 97816LohramMain,Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 [email protected] www.boschrexroth.de

This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does notreleasetheuserfromtheobligationofownjudgmentandverification.Itmustberememberedthatourproductsaresubjecttoanatural process of wear and aging.

16/14

Bosch Rexroth AG

Hydraulics

DBET, DBETE

RE 29162/07.08

Bosch Rexroth AG Hydraulics Zum Eisengieer 1 97816LohramMain,Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 [email protected] www.boschrexroth.de

This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does notreleasetheuserfromtheobligationofownjudgmentandverification.Itmustberememberedthatourproductsaresubjecttoanatural process of wear and aging.