13
For the latest products, information, innovations and solutions, go to bannerengineering.com Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 763-544-3164 • 1-888-373-6767 www.bannerengineering.com P/N 178074

Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

For the latest products, information, innovations and solutions, go tobannerengineering.com

Banner Engineering Corp.9714 Tenth Avenue NorthMinneapolis, Minnesota 55441763-544-3164 • 1-888-373-6767www.bannerengineering.comP/N 178074

Page 2: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

2014

Page 3: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

Banner solves problems for most of the manufacturing companies in the Fortune 500, who rely on innovative automation solutions.

Banner products help manufacture the cars you drive, the TVs you watch, the food you eat, the medicine you take and virtually every product you consume. Whatever the industry, Banner has a solution to help you automate your plants, improve efficiency and manufacture quality products.

The Complete Solution

Sensors

Vision

Wireless

Lighting &Indication

MachineSafety

• Presence

• Absence

• Inspection

• Gating

• Counting

• Measurement

• Position

• Pattern Recognition

• Complex Part Inspection

• Multi-Component Gauging

• Part ID/Orientation

• Assembly Verification

• Print Verification

• Traceability(Bar Code and Text)

• Operator Guidance

• Andon Indication

• Pilot & Stack Light Replacement

• Visual Management

• Bin & Part Picking

• Error Proofing

• Pick-to-Light & Call for Parts

• Visual & Audible Indication

• Agriculture & WaterManagement

• Traffic Monitoring& Control

• Process Control & Monitoring

• Factory Automation

• Commercial & ConsumerMonitoring

• Safety Light Screens

• Safety Modules& Controllers

• Emergency Stop Devices

• Safety Interlocks

• Ergonomic Two-Hand Control& Run Bars

Page 4: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

1More information online at bannerengineering.com

Who is Banner

Customers First Integrity Always

Quality in EverythingNew Solutions — Every Day

3.5Seconds

Somewherein the World

Banner Sensor Installed Every

30,000+

Solutions

Products

Experts

Manufacturing Specialists

CustomizationRapid

Contact Us

Banner Specials

Application

3,000Network of

Professionals

Global Presence

Page 5: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

2

iVu page 490

PresencePLUS page 499

Vision Lighting page 512

Photoelectric page 27

Featured page 28

Rectangle page 110

Right Angle page 158

Barrel page 184

Slot & Area page 222

Miniature page 236

Fiber Optics page 256

Measurement page 314

Optical page 316

Ultrasonic page 334

Radar page 372

Arrays page 380

Special Purpose page 396

Barcode Readers page 398

Registration, Color & Luminescence page 414

Stainless Steel page 428

Clear Object page 454

Temperature page 468

Hazardous Area page 474

Sensors

Brackets 846

Cordsets 904

Misc Accessories 940

Reference 974

Index 1060

Conte

nts Vision

page 19 page 488

Page 6: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

3More information online at bannerengineering.com

Light Screens page 682

Laser Scanner page 710

E-Stop & Stop Control page 716

Interlock Switches page 758

Controllers & Modules page 798

Two-Hand Control page 832

Discrete page 654

Discrete & Analog page 654

Serial page 662

Serial & Ethernet page 664

LED Lighting page 532

Tower Lights page 554

Indicators page 568

Base Mount page 570

Barrel Mount page 582

T-Style page 588

Flat Mount page 594

Touch Buttons page 606

Pick-to-Light page 628

Lighting & Indicators

Wireless Machine Safety

page 528 page 650 page 676

Page 7: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

306

PHOTOELECTRIC FEATURED RECTANGLE RIGHT ANGLE BARREL SLOT & AREA MINIATURE FIBER OPTIC

Glass Fiber Optics• Solve numerous challenging sensing applications in the most hostile

environments, including temperatures up to 480° C, corrosive materials and extreme moisture

• Withstand severe shock and vibration• Ignore extreme electrical noise• Constructed of a combination of optical glass fiber, stainless steel, PVC,

brass, molded thermoplastics and optical-grade epoxy

Choosing Glass or PlasticPlastic fibers are for general purpose use. They tolerate severe flexing, can be cut to length in the field and cost less than glass fibers. Glass fibers are the best choice for challenging environments such as high temperatures, corrosive materials and moisture.

Plastic fibers page 286• Inexpensive and easily cut to length during installation• Bend for a precise fit• Available in high-flex models to withstand flexing• Offered with special jackets that withstand corrosion, impact and abrasion• Available in coiled versions for applications requiring articulated or reciprocating motion• Available in diameters of 0.25, 0.5, 1.0 or 1.5 mm• Can be quickly custom designed and built for your unique applications

Glass fibers page 306• Solve numerous challenging sensing requirements• Ideal for hostile environments such as high temperatures to 480° C,

corrosive materials and extreme moisture• Withstand high levels of shock and vibration• Inherently immune to extreme electrical noise• Available with choice of sheathings: standard stainless-steel flexible conduit, PVC or other flexible tubing• Can be quickly custom designed

Fiber ConstructionCore: Thin glass or plastic center of the

fiber through which light travels

Cladding: Outer optical material surrounding the core that reflects light back into the core

Jacket/ Protective layer to protect fiber Sheath: from damage and moisture

Sheath

Core & cladding

Cladding

Core

Jacket

Glass

Plastic

Page 8: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

307More information online at bannerengineering.com

PHOTOELECTRIC FEATURED RECTANGLE RIGHT ANGLE BARREL SLOT & AREA MINIATURE FIBER OPTIC

* Individual glass fibers are packaged separately.

ASSEMBLY STYLE designator

B = Bifurcated fiberI = Individual fiber*

SENSING END TIP STYLE designator

A = 90° AngleAM = Miniature 90° AngleAT = 90° Angle/ThreadF = FerruleM = Miniature TipMP = Miniature ProbeMT = Miniature ThreadR = Rectangular Bundle TerminationT = ThreadTA = Thread/90° AngleTETA = Thread and Extra Tight 90° Angle

I A T 2 3 S X X

Model Key

FIBER BUNDLE DIAMETER designator

.44 = 0.027 in = 0.69 mm

.5 = 0.032 in = 0.81 mm

.75 = 0.046 in = 1.17 mm1 = 0.062 in = 1.57 mm1.5 = 0.09 in = 2.29 mm2 = 0.125 in = 3.18 mm2.5 = 0.156 in = 3.96 mm

OVERALL LENGTH designator (in feet)

2 = 2 ft. = 610 mm ±38 mm3 = 3 ft. = 914 mm ±38 mm

MODIFICATIONS designator

“MXX” = Sensing end tip modification“M600” = Sensing end withstands 315° C“M900” = Sensing end withstands 480° C

SHEATHING MATERIAL designator

S = Stainless steel flexible conduitP = PVC with galvanized monocoil reinforcing wire

Page 9: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

308

PHOTOELECTRIC FEATURED RECTANGLE RIGHT ANGLE BARREL SLOT & AREA MINIATURE FIBER OPTIC

Fiber Mode End Tip (mm) Features Typical Range (mm) Model

Standard

OPPOSED

12.7 27.9

R 12.7ø 4.8720.3

ø 6.4 • 3.18 mm core diameter• 19 mm bend radius

• 90° angle

M600 M900M600 M900

QS18R55FSME312D12ED12

7151050

250975550

IA23S

ø 6.4

20.3ø 4.8

12.7 27.9

R 12.7

38.1

ø 7.4 • 3.18 mm core diameter• 19 mm bend radius

• 90° angle/thread

• Lenses available

M600 M900M600 M900

QS18R55FSME312D12ED12

9001050

250975550

IAT23S

ø 5.8 ø 7.4 ø 4.8

12.712.7

• 3.18 mm core diameter• 19 mm bend radius• Smooth ferrule

M600 M900M600 M900

QS18R55FSME312D12ED12

9901050

975550

IF23P

ø 3.0 ø 3.8

12.712.7

• 0.69 mm core diameter• 9.5 mm bend radius• Miniature thread

QS18R55FSME312D12ED12

NA7525

10270

NA

IMT.442P

ø 8.0ø 6.4

38.112.7

• 3.18 mm core diameter• 19 mm bend radius• Thread

• Lenses available

M600 M900M600 M900

QS18R55FSME312D12ED12

9001050250975550

IT23S

ø 8.0

ø 6.4 38.1 15.812.7

27.9

ø 4.8

R 9.7

• 3.18 mm core diameter• 19 mm bend radius

• 90° angle/thread

M600 M900M600 M900

QS18R55FSME312D12ED12

11001050

250925550

ITA23S

Miniature Probe

OPPOSED

ø 8.0ø 1.5ø 6.4

25.435.6

R 3.05

4.8

• 1.17 mm core diameter• 19 mm bend radius

• 90° angle

M600 M900

QS18R55FSME312D12ED12

11013050

180170

IAM.752S

ø 7.4 ø 1.5ø 4.6ø 6.4

12.7 12.7 25.4

• 1.17 mm core diameter• 19 mm bend radius• Non-bendable probe

M600 M900

QS18R55FSME312D12ED12

NA13050

180170

NA

IM.752S

ø 3.0 ø 3.8 ø 1.5

25.412.7

• 1.17 mm core diameter• 9.5 mm bend radius

QS18R55FSME312D12ED12

NA13050

180170

NA

IMP.753P

NA: Not recommended.

M600 M900Available 315° C models. Add M600 to end of model number (example, IA23SM600).

M600 M900 Available 480° C models. Add M900 to end of model number (example, IA23SM900).Dimensions may vary for these models.

Page 10: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

309More information online at bannerengineering.com

PHOTOELECTRIC FEATURED RECTANGLE RIGHT ANGLE BARREL SLOT & AREA MINIATURE FIBER OPTIC

Fiber Mode End Tip (mm) Features Typical Range (mm) Model

Area Sensing (Array)

OPPOSED

ø 6.438.1

25.4

12.7

50.8

2x 4.8

• 3.69 mm core diameter• 19 mm bend radius

• Straight exit; 38 mm widthM600 M900

QS18R55FSME312D12ED12

7601175350975580

IR2.53S

ø 6.42.54

19.1

11.7

2x 3.2

19.1

• 3.18 mm core diameter• 19 mm bend radius

• Straight exit; 10 mm widthM600 M900

QS18R55FSME312D12ED12

10451050

250925550

IR23S

Side View

OPPOSED

25.4

ø 5.3ø 5.1 ø 4.8ø 3.05

5.3

12.7

• 2.29 mm core diameter• 19 mm bend radius• Ultra-compact head

M600 M900

QS18R55FSME312D12ED12

250600180500450

IA1.53SMETA

35.1

ø 6.4ø 5.3 ø 3.05

7.1

• 2.29 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

340600180500450

IA1.53SMTA

ø 8.0ø 6.45/16-24 thd brass

2 jam nuts included

38.112.7 25.4

ø 4.8ø 3.05

5.3

• 2.29 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

390600180500450

ITETA1.53S

Vacuum

OPPOSED 12.0 3.0

M4 x 0.7

M2.5 x 0.045

ø 4.2 • 1.27 mm core diameter• 19 mm bend radius

QS18R55FSME312D12ED12

Contact factory for sensing range IMT.753SMVF

Extended Range Lens

45.7

ø 14.3

5/16" - 24 thread

lens optic

• Glass lens withstands 315° C L9

58.4

ø 28.6

5/16" - 24 thread

lens optic

• Plastic housing withstands 105° C L16F

58.4

ø 28.6

5/16" - 24 thread

lens optic

• Aluminum housing withstands 315° C L16FAL

58.4

ø 28.6

5/16" - 24 thread

lens optic

• Stainless steel housing withstands 480° C L16FSS

M600 M900Available 315° C models. Add M600 to end of model number (example, BA23SM600).

Continued on next page

Page 11: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

310

PHOTOELECTRIC FEATURED RECTANGLE RIGHT ANGLE BARREL SLOT & AREA MINIATURE FIBER OPTIC

Fiber Mode End Tip (mm) Features Typical Range (mm) Model

Standard

DIFFUSE

38.1

12.7 27.9

ø 4.820.3

ø 6.4

• 3.18 mm core diameter• 19 mm bend radius

M600 M900M600 M900

QS18R55FSME312D12ED12

8011025

180150

BA23S

ø 6.4

5/16-24UNF brass2 brass jam

nuts included

20.3ø 4.8

12.7 27.9

38.1

ø 7.4

38.1 • 3.18 mm core diameter• 19 mm bend radius

M600 M900M600 M900

QS18R55FSME312D12ED12

9011025

180150

BAT23S

ø 5.8

38.1

ø 7.4ø 4.8

12.712.7

• 3.18 mm core diameter• 19 mm bend radius

QS18R55FSME312D12ED12

10011025

180150

BF23P

ø 3.0

38.1

ø 3.8#8-32 thd brass

2 jam nuts included

12.712.7

• 0.69 mm core diameter• 9.5 mm bend radius

QS18R55FSME312D12ED12

NANA1

105

NANA

BMT.442P

ø 8.0ø 6.4 5/16-24 thd brass2 jam nuts included

38.112.738.1

• 3.18 mm core diameter• 19 mm bend radius

M600 M900M600 M900

QS18R55FSME312D12ED12

10011025

180150

BT23S

ø 8.0

ø 6.4

5/16-24 thd brass2 jam nuts included

38.1 15.8

27.9

12.7

ø 4.838.1

• 3.18 mm core diameter• 19 mm bend radius

M600 M900M600 M900

QS18R55FSME312D12ED12

8511025

180150

BTA23S

Miniature Probe

DIFFUSE

ø 8.0ø 1.5ø 6.4

25.435.6

R 3.05

4.8

38.1

• 1.17 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

NA113

4225

NA

BAM.752S

ø 7.4

25.412.7 12.738.1

ø 4.6 ø 1.5ø 6.4

• 1.17 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

NA113

4225

NA

BM.752S

ø 1.5

25.412.738.1

ø 3.0 ø 3.8

• 1.17 mm core diameter• 9.5 mm bend radius

QS18R55FSME312D12ED12

NA113

4225

NA

BMP.753P

M600 M900Available 315° C models. Add M600 to end of model number (example, BA23SM600).

M600 M900 Available 480° C models. Add M900 to end of model number (example, BA23SM900). Dimensions may vary for these models.

Page 12: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

311More information online at bannerengineering.com

PHOTOELECTRIC FEATURED RECTANGLE RIGHT ANGLE BARREL SLOT & AREA MINIATURE FIBER OPTIC

Fiber Mode End Tip (mm) Features Typical Range (mm) Model

Area Sensing (Array)

DIFFUSE

ø 6.4

38.1

25.4

12.750.8

2x 4.8

6.4 38.1

• 3.69 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

7512030

180155

BR2.53S

ø 6.4

38.1

2.54

19.1

11.7

2x 3.2

19.1

• 3.18 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

11011025

180150

BR23S

Side-View

DIFFUSE

25.4

ø 5.3ø 5.1 ø 4.8

ø 3.05

12.738.1

• 2.29 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

456520

135125

BA1.53SMETA

35.1

ø 5.3 ø 6.4 ø 3.05

38.1

• 2.29 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

506020

135125

BA1.53SMTA

ø 8.0ø 6.4 5/16-24 thd brass2 jam nuts included

38.112.7 25.4

ø 4.8ø 3.05

5.3

38.1

• 2.29 mm core diameter• 19 mm bend radius

M600 M900

QS18R55FSME312D12ED12

306020

135125

BTETA1.53S

Convergent Beam Spot

DIFFUSE

45.7

ø 14.3

5/16" - 24 thread

lens optic • Glass lens; withstands 315° C • Focuses light to .80 mm with

ø 1.6 mm fiberContact factory for range information L10

M600 M900Available 315° C models. Add M600 to end of model number (example, BA23SM600).

Page 13: Banner Engineering Corp. - ideadigitalcontent.com · Banner Engineering Corp. 9714 Tenth Avenue North Minneapolis, Minnesota 55441 ... ø 6.4 ø 7.4 ø 4.6 ø 1.5 12.7 12.7 25.4 •

312

PHOTOELECTRIC FEATURED RECTANGLE RIGHT ANGLE BARREL SLOT & AREA MINIATURE FIBER OPTIC

Glass Fiber Optics SpecificationsConstruction Combination of optical glass fiber, stainless steel or PVC, brass, molded thermoplastics, and optical-grade epoxy. Optical fiber is F2 core,

EN1 clad, approx. 50 µm diameter per strand. Flexible steel interlock sheathing is 302 stainless.

Sensing Range Refer to the specific fiber optic to be used

Bend Radius Inside bend radius must be 12 mm or greater for PVC covered fiber optic assemblies, and 25 mm or greater for stainless steel armored cable covered fibers

Length Standard length for assemblies is 915 mm; see dimension diagramsMost models are available from the factory with shorter or longer cable lengths, up to 18 m max

Length Dimension Tolerance

Overall assembly length: ±12 mm per 300 mm of lengthShrink junction dimensions: ±12 mm

Implied Dimensional Tolerances All dimensions are in millimeters: x = ±2.5 mm, x.x = ±0.25 mm and x.xx = ±0.12 mm, unless specified.

Operating Conditions Fiber assemblies with stainless-steel (SS) sheathing and metal end tips: -140° to +249° CFiber assemblies with PVC sheathing and/or plastic end tips: -40° to +105° CSpecial order assemblies with SS sheathing and metal end tips and model suffix “M600”: -140° to +315° C* Special order assemblies with SS sheathing and metal end tips and model suffix “M900”: -140° to +480° C*; note dimensional

changes from STD models

* sensing end tip only

! Application Notes and Warnings !

The ends of glass fiber optic assemblies are optically ground and polished. Care taken in this manufacturing process accounts for the light coupling efficiency of the fiber optic assembly. As a result, glass fiber assemblies cannot be shortened, spliced or otherwise modified.

Use caution when applying fiber optics in hazardous locations. Although fiber optic assemblies are by themselves, intrinsically safe, the sensor and associated electronics must be LOCATED IN A SAFE ENVIRONMENT. Alternatively, fiber optics may be used with sensor model SMI912FQD. This sensor is approved for use inside hazardous areas when used with an appropriate intrinsic barrier. Also, see NAMUR sensor models Q45AD9F and MIAD9F. Fiber optics do not necessarily provide a hermetic seal between a hazardous environment and the safe environment.

In applications where glass fibers are used to insulate the control from high voltage, specify silicone rubber, Teflon®, or high-density polyethylene sheathing with no reinforcing wire in the cable. It is the responsibility of the user to test each fiber optic assembly for insulation capacity.

Do not subject the fibers to sharp bends, pinching, repeated flexing or high levels of radiation.

When ordering fiber lengths in excess of 1 m, take into account light signal reduction of 5 percent per 300 mm of additional length.

Teflon® is a registered trademark of Dupont™.

1

2

3

4

5