Complete Load Banks SolutionsJMHING
Complete Load Bank Soluions
1
We have manufactured load banks for 10 years,
and our Chinese brand has become Chinese a
renowned brand. Our main projects are OEM for
some major PLC’s with a series of load banks from
1kW to 60MW. We have a team of specialized
designers and electrical technicians along with
R&D, and we are developing a remote method of
controlling banks without an actual presence.
JMHING (HK) Electronic Technology Co., Ltd. , is
an established hi-tech brand with over 10 years
manufacturing experience, specializing in the
development and manufacture of stable continuous
and variable load banks with tailor-made testing
solutions to meet all requirements. JMHing is 100%
committed to maintaining the highest standards that
you have every right to expect throughout Design,
Manufacture and Product Support.
We have enjoyed some long cooperation’s with
some brands you may recognize and specialize in
developing bespoke ranges for companies from the
ideas level through to manufacture and installation.
With over a decade of extensive experience
allowing JMHing the capability to satisfy any load
bank design requirement, from standard size
resistive and reactive load banks to
custom-designed load banks of any size at any
voltage and frequency, from the basic manual
control to automatic or TCP/IP remote control. If you
have any questions or requirements, please contact
us without any hesitation.
When you build a data center, any unexpected glitch during commissioning can cause serious project delays, wasted
productivity, and significant budget overruns. So integrating rack mounted load banks into the design phase can help
our data center clients keep projects on budget and on time.
JMHing’s rack mounted load banks are designed especially for data center commissioning testing, they precisely
simulate high density server loads and air flow for the most accurate and complete hot aisle/cold aisle testing. We
provide resistive, reactive and capacitive load banks in low or medium voltage to cover the entire scope of your
commission and testing requirements. Our dedicated solutions for data center commissioning include:
Rack Mounted Load Banks
Capacity and
design voltage
Minimum load step
Air quantity
Dimensions
Options
Cables
Models 120VAC-3kW 230VAC-3kW 230VAC-6kW 230VAC-10.5kW 270VDC-3kW 270VDC-6kW
3kW@120VAC 3kW@230VAC 6kW@230VAC 10.5kW@230VAC 3kW@270VDC 6kW@270VDC
Or units can be designated at any capacity and voltage made to order
250W 250W 500W 500W 100W 100W
Or units can be designated at any minimum load step made to order
3U 4U 6U 9U 4U 4U
19” standard rack
Air flow control and display, Digital meter, Remote control
C13 C14
2
Purely resistive load bank is the most common type of load bank, and
it proves equivalent loading of both generator and prime mover. That
is, for each kilowatt of load applied to the generator by the load bank,
an equal amount of electrical energy converts to heat by power
resistors, in a general way, this heat must be dissipated from the load
bank by air forced means or other convection.
The JMHing’s resistors are made by high quality finned tubular heating
elements, they are of the type where the surface area is enlarged by a
strip in order to heat gases. At high power the surface temperature is
small and the heating element is short. Meanwhile, Load elements are
cooled usually via Fan Forced Air, blower power is typically provided
by an outside source. Selected load banks are available with blower
power derived from the power source under test.
AC Resisive Load Banks
3
JMHing’s AC resistive load banks can be further divided into these categories:
A resistive load bank easily carried or pushed on
strong robust swivel wheels for testing and
maintaining AC power equipment such as UPS
systems and generators up to 150kW.
A resistive load bank for testing and maintaining
AC power equipment such as UPS systems and
generators at one location up to 4600kW. Many
models can be used as modular building blocks for
applications requiring capacity of tens or hundreds
of megawatts. Also the load banks can be loaded
on a trailer for more flexibility.
1-6kW
or units can be designated at any capacity made to order
230VAC
or units can be designated at any voltage made to order
1 phase: 26A
1 phase: 26A
50Hz/60Hz
PF=1.0
100W
or units can be designated at any minimum load step
Voltage, Current, Frequency, Power and PF displayed by digital meter
Overheating alarm, Short circuit protection, Overheating protection, Emergency stop button, All protection can be configured
optionally
Manual control by MCBs or button switches or toggle switches
horizontal
Force-air cooling
49*60*21(cm)
Handle panel or PC remote control selectable
Maintains maximum capacity in ambient conditions up to 55° C, and 95% humidity
Capacity
rated voltage
Rated current
Frequency
PF
Minimum load step
Display
Protection
Control mode
Air flow
Dimensions
Options
Ambient parameters
Models 230VAC-6kW-R 480VAC-30kW-R 480VAC-60kW-R 480VAC-100kW-R 480VAC-200kW-R 480VAC-400kW-R
10-30kW
480VAC
1 phase: 36A
3 phases: 108A
50Hz/60Hz
PF=1.0
100W
vertical
Force-air cooling
50*67*116(cm)
30-60kW
480VAC
1 phase: 72A
3 phases: 216A
50Hz/60Hz
PF=1.0
100W
horizontal
Force-air cooling
51*97*110(cm)
60-100kW
480VAC
1 phase: 120A
3 phases: 361A
50Hz/60Hz
PF=1.0
1kW
horizontal
Force-air cooling
81*97*155(cm)
100-200kW
480VAC
1 phase: 240A
3 phases: 721A
50Hz/60Hz
PF=1.0
1kW
horizontal
Force-air cooling
80*120*161(cm)
200-400kW
480VAC
1 phase: 481A
3 phases: 1443A
50Hz/60Hz
PF=1.0
1kW
horizontal
Force-air cooling
80*180*150(cm)
AC resisive load banks
AC Small Portable: AC Stationary:
4
A resistive load bank on strong robust swivel wheels
for testing and maintaining larger AC power
equipment such as UPS systems and generators up
to 1000kW.
A resistive load bank for testing and maintaining
larger generators and other AC power equipment
up to 7000kW and up to 15,000 volts.
AC Large Portable: AC Medium/High Voltage:
Resisive/Reacive Load Banks
The resistive/reactive combination load banks are used to test the engine
generator set or other electromagnetic devices working at their rated power
factor. We mainly manufacture three types of resistive/reactive load banks as
follow for different testing purpose.
RL load bank, combined with resistive load and inductive load to simulate
lagging power factor, is mainly for generator and UPS testing. In most cases this
is 0.8 power factor, and to achieve a 0.8 power factor, the reactive(inductive)
load should be sized at 75% of the resistive load bank kW rating.
6kW
4.5kVAR
or units can be specified by customer
Single Phase, AC230V Three Phase 480VAC, or units can be specified by customer
Resistive amperes
per phase: 26A
Reactive amperes
per phase: 20A
50Hz and60Hzare available
0.8
100W, 100VAR
or units can be specified by customer
Voltage, Current, Frequency, Power and PF displayed by digital meter
Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button, All
protection can be configured optionally
Manual control by MCB’ s or push buttons
Horizontal, Force-air cooling
51*50*110 (cm)
Handle panel or PC remote control are selectable
30kW
22.5kVAR
Resistive amperes
per phase: 36A
Reactive amperes
per phase: 27A
0.8
100W, 100VAR
90*90*160 (cm)
60kW
45kVAR
Resistive amperes
per phase: 72A
Resistive amperes
per phase: 120A
0.8
100W, 100VAR
90*90*200 (cm)
500kW
375kVA
Reactive amperes
per phase: 180A
Reactive amperes
per phase: 451A
0.8
1kW, 1kVAR
120*120*200 (cm)
(3sets)
200kW
150kVAR
Reactive amperes
per phase: 54A
Reactive amperes
per phase: 90A
0.8
1kW, 1kVAR
90*90*200 (cm)
(3set)
100kW
75kVAR
Resistive amperes
per phase: 240A
Resistive amperes
per phase: 601A
0.8
1kW, 1kVAR
120*120*200 (cm)
Resistive load
Inductive load
Capacity
Rated voltage
Rated current at
480VAC
Frequency
PF
Min. load step
Display
Protection
Control mode
Air flow
Dimensions
Options
Model 230VAC-6kW-RL 480VAC-30kW-RL 480VAC -60kW-RL 480VAC -100kW-RL 480VAC -200kW-RL 480VAC -500kW-RL
Resisive/inducive load banks-RL
5
We also manufacture RLC load banks, in this type of load banks, inductive or
capacitive load are reactive only and must be used in combination with a resistive load
to provide the desired load profile to test a power system. Reactive loads banks can
provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
RCD load bank is similar to a reactive load bank in rating and
purpose, except that leading power factor loads are created. These
loads simulate certain electronic or non-linear loads typical of
telecommunications, computer or UPS industries.
Capacity
Rated voltage
Frequency
PF
Min. load step
Models 480VAC-30kW-RLC 480VAC -60kW-RLC 480VAC -100kW-RLC
Resistive load: 30kW Resistive load: 60kW Resistive load: 100kW
Inductive load: 30kVAR Inductive load: 60kVAR Inductive load: 100kVAR
Capacitive load: 30kVAR Capacitive load: 60kVAR Capacitive load: 60kVAR
or units can be specified by customer
Three Phase 480VAC, or units can be specified by customer
50Hz and 60Hz are available
0.1-1
100W, 100VAR 1kW, 1kVAR 1kW, 1kVAR
or units can be specified by customer
Resisive/inducive/capaciive load banks-RLC
Resistive load: 10kW
Capacitive load: 10kVAR
or units can be designated by customer
240VAC Three phase 415VAC, or units can be designated by customer
96A
\
50Hz or 60Hz
0.6-1.0
100W, 100VAR
or units can be designated by customer
Voltage, Current, Frequency, Power and PF displayed by digital meter
Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button, All
protection systems can be configured optionally
Manual control by MCBs or button switches
Horizontal, Force-air cooling
51*63*120 (cm)
Capacity
Rated voltage
Maximum
current
Frequency
PF
Min. load step
Display
Protection
Control mode
Air flow
Dimensions
Model 240VAC-10kW-RCD 415VAC-30kW-RCD 415VAC-100kW-RCD 415VAC-250kW-RCD 415VAC-400kW-RCD
Resisive/ capaciive load banks-RCD
Resistive load: 30kW
Capacitive load: 30kVAR
1P: 96A
3P: 288A
50Hz or 60Hz
0.6-1.0
100W, 100VAR
51*97*120 (cm)
Resistive load: 100kW
Capacitive load: 100kVAR
1P: 319A
3P: 957A
50Hz or 60Hz
0.6-1.0
1kW, 1kVAR
80*140*185(cm)
Resistive load: 250kW
Capacitive load: 250kVAR
1P: 798A
3P: 2394A
50Hz or 60Hz
0.6-1.0
1kW, 1kVAR
80*150*155(cm)
Resistive load: 400kW
Capacitive load: 400kVAR
1P: 1278A
3P: 3834A
50Hz or 60Hz
0.6-1.0
1kW, 1kVAR
80*150*190(cm)
6
DC Load BanksJMHing constant current DC load banks are designed for acceptance testing, discharge testing, battery capacity
testing, battery maintenance, engineering examination and other tests for DC power with loads. The standard range
starts at a nominal 24V/100A up to 1000V/500A, with a wide range of intermediate voltages and currents. Dual and
multiple voltage is available on some units.
Also applications for JMHING DC load banks vary according to our worldwide customers’ needs. We have the
expertise and capacity to deliver a range of larger load banks, for example:2500A@48V.
50kW
or units can be designated by customer
48VDC
1042A
100W or 1A
or units can be designated by customer
Voltage, Current and Power displayed by digital meter
Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button,
All protections can be configured optionally
Manual control by MCBs
Horizontal, Force-air cooling
50*97*110 (cm)
Handle panel, PC remote control or timer selectable
Capacity
Rated voltage
Rated current
Min. load step
Display
Protection
Control mode
Air flow
Dimensions
Options
Models 48VDC-50kW 100VDC-50kW 200VDC-100kW 400VDC-200kW 800VDC-400kW 1000VDC-500kW
50kW
100VDC
500A
100W or 1A
50*97*110 (cm)
100kW
200VDC
500A
100W or 1A
60*120*145 (cm)
200kW
400VDC
500A
100W or 1A
80*120*161 (cm)
400kW
800VDC
500A
1kW or 1A
80*180*150 (cm)
500kW
1000VDC
500A
1kW or 1A
80*180*190 (cm)
DC load banks
7
JMHing offers several models of stationary resistive or reactive load banks for testing and maintaining generators and
other AC power systems up to 4600 kW. Many models can be used as modular building blocks for applications
requiring a capacity of tens or hundreds of megawatts.
JMHing also manufactures several models of medium/high voltage (up to 12kV) resistive load banks for testing and
maintaining large generators and other AC power systems up to 6000 kW. We offer the convenience of direct connect
medium voltage load banks without the need for transformers.
Staionary Load Banks
8
What we can do?
Contact Informaion
JMHing manufactures load banks and our engineering team has extensive working experience with OEMs,
manufacturers and customized load bank designers and builders. Also as we are located in Shenzhen, (which is the
largest market of electronic products in Asia) we have an abundance of technical specialists within reach along with
our own team of R&D. This diverse team of engineering professionals will communicate, design, and deliver load bank
technology solutions that advance your business, at a speed that will impress.
JMHing strives to understand our customers’ needs and expectations, while continuously improving our operations to
achieve total customer satisfaction.
Our
services
UK Office (Yorkshire, UK)
Unit 10 Kelleythorpe Industrial Estate Driffield YO25
9DJ
Phone: +44 01377 252874
Email: [email protected]
UK Office (Yorkshire, UK)
Unit 10 Kelleythorpe Industrial Estate Driffield
YO25 9DJ
Phone: +44 01377 252874
Email: [email protected]
Appearance and printing solutions
Automatic load and deload solutions
Temperature control and display systems
Air flow control and display systems
PC software control systems
TCP/IP remote control systems
Wireless solutions
Substation protocols solutions
Trailer solutions
Outdoor solutions
1
2
3
4
5 10
9
8
7
6
9