Page 1 of 2
To: API Lubricants Group Cc: Lubricants Group Mailing List
API Ballot for Technical Principles for New Viscosity Grades and Read Across At the October 11, 2018 Lubricants Standards Group (LSG) Meeting the Lubricants Group reviewed the BOI/VGRA Task Force Proposal 6-Sequence X Technical Principles Read Across Table. Revised Proposal 6 establishes Table F-y—Technical Principles for New Viscosity Grades and Read Across for new viscosity grades.
BOI/VGRA Revised Proposal 6 is given in Attachment 1, page 4. The Motion to Ballot BOI/VGRA Revised Proposal 6 is given on Attachment 1, Page 5. Background Information can be found Attachment 1, pages 6-10. After review and discussion, the LSG agreed by voice vote to Ballot Table F-y—Technical Principles for New Viscosity Grades and Read Across.
• Motion to Ballot Proposal 6 Table F-y—Technical Principles for New Viscosity Grades and Read Across
Motion by: Eric Kalberer
Second: Josh Frederick
Voice Vote: For = 17 | Against = 0 | Abstain = 0
Motion Passed
Page 2 of 2
Lubricants Group Members should use the API eBallot System to cast their vote and make comments. The eBallot Link is: http://Ballots.api.org. The Lubricants Group Member votes will be counted, and all received comments reviewed and considered before the ballot results are final. Non-Lubricants Group Members should comment on the Ballot Motion using the eBallot system. The eBallot Link is: http://Ballots.api.org. All comments on the Ballot Motion will be reviewed before the ballot results are final. This eBallot will close on November 30, 2018. All Votes and/or Comments must be received by the close date.
Attachment 1Proposal 6 Technical Principles for New Viscosity Grades
and Read Across
API Lubricants GroupBOI VGRA Task Force Proposals 5, 6
Sequence X VGRA
October 11, 2018
1
2
Proposal 5:Sequence X VGRA Read Table RecommendationAdd Table F.xx to Annex F
Table F-xx Groups II, III and IV Viscosity Read Across: Sequence X Test
Note: 1. Tested formulations containing Group I and/or Group V stocks must contain an equal amount of the same base stock in the
finished oil blend for application of viscosity grade read-across
Can Be “Read-Across1” to:
Test Run on 0W-16 0W-20 5W-20 5W-30 10W-30 10W-40
0W-16 NA X X X X X
0W-20 X NA X X X X
5W-20 X X NA X X X
5W-30 X X X NA X X
10W-30 X X X X NA X
10W-40 X X X X X NA
3
Proposal 6:New VGRA Technical Principles TableAdd Table F.y to Annex F
Table F-y—Technical Principles for New Viscosity Grades and Read Across
Passenger Car Motor Oils X
a Detergent (dispersant)- inhibitor (DI) content of the read-across viscosity grade shall be equal to or higher than that of the original viscosity grade. The increase in DI is limited to the maximum allowed by the ACC Code
b Base stock blend kinematic viscosity at 100°C of the read-across viscosity grade must be equal to or higher than that of the original viscosity grade, considering the precision of the test method
NA
c The viscosity modifier (VM) content of the read-across viscosity grade must be equal to or lower than that of the original viscosity grade
Note 3
Applies to oils with HTHS150 ≥ 2.3 mPa•s
1. = principle is applicable; NA = not applicable.2. New viscosity grades and associated read-across can only be added after review by the API BOI/VGRA Task Force and approval by the API
Lubricants Group.3. Viscosity Modifier content must be no more than 1.7 times higher than viscosity modifier content in the oil on which test was run4. For dispersant-type VM, the VM content of the read-across viscosity grade must be equal to or higher than the original viscosity grade.5. Read-across viscosity grades must contain an equal amount of the same Group V base stock (e.g., ester) in the finished oil blend if a Group V
base stock is used in the original viscosity grade
4
Revised Proposal 6:New VGRA Technical Principles TableAdd Table F.y to Annex F
Table F-y—Technical Principles for New Viscosity Grades and Read Across
Passenger Car Motor Oils X
a Detergent (dispersant)- inhibitor (DI) content of the read-across viscosity grade shall be equal to or higher than that of the original viscosity grade. The increase in DI is limited to the maximum allowed by the ACC Code
b Base stock blend kinematic viscosity at 100°C of the read-across viscosity grade must be equal to or higher than that of the original viscosity grade, considering the precision of the test method
NA
c The viscosity modifier (VM) content of the read-across viscosity grade must be equal to or lower than that of the original viscosity grade
Note 3
Applies to oils with HTHS150 ≥ 2.3 mPa•s
1. = principle is applicable; NA = not applicable.2. New viscosity grades and associated read-across can only be added after review by the API BOI/VGRA Task Force and approval by the API
Lubricants Group.3. Viscosity Modifier content must be no more than 1.7 times higher than viscosity modifier content in the oil on which the test was run because
this was the highest level of VM tested in the BOI/VGRA Matrix.4. For dispersant-type VM, the VM content of the read-across viscosity grade must be equal to or higher than the original viscosity grade.5. Read-across viscosity grades must contain an equal amount of the same Group V base stock (e.g., ester) in the finished oil blend if a Group V
base stock is used in the original viscosity grade
Motion to BallotMotion to Ballot the BOI/VGRA Task Force Revised Proposal 6 for Technical Principles Table for Seq. X.
• Motion by Eric Kalberer• Second Josh Frederick• For = 17 Against = 0 Abstain = 0
5
Background Information
6
Seq. X BOI/VGRA Matrix Statisticians ReportSept. 18, 2018
7
Seq. X BOI/VGRA Matrix Statisticians ReportSept. 18, 2018
8
Seq. X BOI/VGRA Matrix Statisticians ReportSept. 18, 2018
9
Seq. X : Impact of Relative Viscosity Modifier Treat Level
10
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
0.5 1.0 1.5 2.0
Tech 270
Cha
in S
tret
ch(R
aw)
6 results
Error bars reflect σ applied to average at each VM level
Average
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
0.5 1.0 1.5 2.0
Tech 2717 results
Error bars reflect σ applied to average at each VM level
Grp II Slate K4.2 cSt BOV
Grp III Slate D4.9 cSt BOV
Grp III Slate D6.2 cSt BOV
Average
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
0.5 1.0 1.5 2.0
Tech 101118 results
Error bars reflect σ applied to average at each VM level
Grp III Slate D4.2 cSt BOV
Average
All test data included
Additional information provided by ExxonMobil post BOI/VGRA Recommendation and not part of the Statistician’s Report.