Upload
nguyendieu
View
214
Download
0
Embed Size (px)
Citation preview
BALAZS TEST RESULTSTM
Air Liquide Electronics U.S. LP
46409 Landing Parkway, Fremont CA 94538
Telephone (510) 624-4000 Fax (510) 657-2292
MS JULES POISSON
TELEDYNE-DALSA SEMICONDUCTOR
18 BOULEVARD DE L'AEROPORT
BROMONT QC J2L 1S7
Phone: (450) 534-2321
Work Order: 17-11505
Report Date:
Order Date: 9-Nov-17
P.O.: 501266
Release:
Approved By: Tiffany Wilkus
ORGANIC LAB MANAGERTitle:Email: [email protected]
11-Dec-17
3Revision:
If you have any questions regarding the results, please call Tiffany Wilkus at (510) 624-4045
I. Background and Summary:
Two wafer samples (184021 Wafer 1 and 185114 Wafer 21) were submitted for analysis to determine the
concentrations of elemental contaminants, polybrominated biphyenyls (PBBs) and polybrominated diphenyl
ethers (PBDEs), and select phthalates present per the European RoHS directive.
II. Analysis Techniques:
The wafers were ground into a fine powder and different aliquots were taken for each analysis.
RoHS Parameters: Analyses for metals were conducted following the guidelines set out in IEC 62321,
Ed. 1, Revision 111/54/CDV, “Procedures for the Determination of Levels of Six Regulated Substances in
Electrotechnical Products”. The sample was hydrolyzed with concentrated acid prior to taking aliquots for
the metals analysis.
Trace elements were analyzed by ICP-MS in accordance with the documents EN1122, ICS 83.080.01,
Method “A” “Plastics - Determination of cadmium - Wet decomposition method”, and lead by EPA 3050B
Acid Digestion of Sediments, Sludges and Soils.
Hexavalent chromium (Cr(VI)) was analyzed by UV-Vis Spectrometry with a Cary 50 UV-Vis system
following ISO 3613:2000(E), “Chromate Conversion Coatings on Zinc, Cadmium, Aluminum-Zinc Alloys
and Zinc-Aluminum Alloys Test Methods”. This is the full immersion boiling water extraction.
These results were obtained by following standard laboratory procedures and are only representative of the sample as received by the laboratory.
The liability of AIR LIQUIDE - BALAZS NanoAnalysis ("Balazs") should not exceed the amount paid for this report. In no event shall Balazs be liable for
special of consequential damages. Client agrees not to use Balaz's name in reporting results obtained from tests performed by Balazs written consent
as to such use. Report shall not be reproduced except in full, without the written permission of Balazs.
Page 1 of 6
Air Liquide Electronics U.S. LP
46409 Landing Parkway, Fremont CA 94538
Telephone (510) 624-4000 Fax (510) 657-2292
MS JULES POISSON
TELEDYNE-DALSA SEMICONDUCTOR
Release:
501266P.O.:
9-Nov-17Order Date:
Report Date:
17-11505Work Order:
Approved By: Tiffany Wilkus
ORGANIC LAB MANAGERTitle:
11-Dec-17
Organobromines (polybrominated biphenyls & polybrominated diphenyl ethers) were evaluated in
accordance with the document labeled “Volatile Organic Compounds by Gas Chromatography/Mass
Spectrometry (GC/MS)”, EPA-1614 Draft Method in conjunction with the appropriate preparation technique.
III. Summary of Results:
A) RoHS Evaluation: None of the parameters listed below were detected in either sample at
concentrations in excess of those permitted under the RoHS directive which are:
Cadmium 100 ppmw (0.01% by weight)
Mercury 1,000 ppmw (0.1% by weight)
Hexavalent chromium 1,000 ppmw (0.1% by weight)
PBBs, PBDEs 1,000 ppmw (0.1% by weight)
DEHP 1,000 ppmw (0.1% by weight)
DBP 1,000 ppmw (0.1% by weight)
BBP 1,000 ppmw (0.1% by weight)
DIBP 1,000 ppmw (0.1% by weight).
Additionally, lead was not detected in sample 184021 Wafer 1 at or above 1,000ppmw.
Lead was detected in 185114 Wafer 21 at 27,674 ppmw.
These results were obtained by following standard laboratory procedures and are only representative of the sample as received by the laboratory.
The liability of AIR LIQUIDE - BALAZS NanoAnalysis ("Balazs") should not exceed the amount paid for this report. In no event shall Balazs be liable for
special of consequential damages. Client agrees not to use Balaz's name in reporting results obtained from tests performed by Balazs written consent
as to such use. Report shall not be reproduced except in full, without the written permission of Balazs.
Page 2 of 6
Air Liquide Electronics U.S. LP
46409 Landing Parkway, Fremont CA 94538
Telephone (510) 624-4000 Fax (510) 657-2292
MS JULES POISSON
TELEDYNE-DALSA SEMICONDUCTOR
Release:
501266P.O.:
9-Nov-17Order Date:
Report Date:
17-11505Work Order:
Approved By: Tiffany Wilkus
ORGANIC LAB MANAGERTitle:
11-Dec-17
Sample: 1134850 [184021 WAFER 1] 200MM SILICON WAFERSite ID:
Result ValueComponent Detection Limit Units
G0342-N-R GC/MS Analysis for Organic Bromine Compounds (IEC 62321 Edition 1 111/116/FDIS)
Polybrominated biphenyl (PBB) / 1 10 * ppm
Polybrominated diphenyl ether (PBDE) / 1 10 * ppm
G0344-N-R RoHS ICP Elemental Analysis for Cd, Pb, and Hg
Cadmium (Cd) / 1 1 * ppm
Lead (Pb) / 1 1 * ppm
Mercury (Hg) / 1 30 * ppm
G0345-N-R Hexavalent Chromium by UV-VIS (EC Method)
Hexavalent chromium (Cr+6) / 1 1.0 * ppm
G0315-N-R Gas Chromatography / Mass Spectrometry (GC/MS), Direct Injection Liquids
Dibutyl phthalate (DBP) 10 * ppm
Di(2-ethylhexyl)phthalate (DEHP) 10 * ppm
Benzyl butyl phthalate (BBP) 10 * ppm
Diisobutyl phthalate (DIBP) 10 * ppm
* = Analysis revealed that the analyte was not found at or about the detection limit
These results were obtained by following standard laboratory procedures and are only representative of the sample as received by the laboratory.
The liability of AIR LIQUIDE - BALAZS NanoAnalysis ("Balazs") should not exceed the amount paid for this report. In no event shall Balazs be liable for
special of consequential damages. Client agrees not to use Balaz's name in reporting results obtained from tests performed by Balazs written consent
as to such use. Report shall not be reproduced except in full, without the written permission of Balazs.
Page 3 of 6
Air Liquide Electronics U.S. LP
46409 Landing Parkway, Fremont CA 94538
Telephone (510) 624-4000 Fax (510) 657-2292
MS JULES POISSON
TELEDYNE-DALSA SEMICONDUCTOR
Release:
501266P.O.:
9-Nov-17Order Date:
Report Date:
17-11505Work Order:
Approved By: Tiffany Wilkus
ORGANIC LAB MANAGERTitle:
11-Dec-17
Sample: 1134851 [185114 WAFER 21] 150MM SILICON WAFERSite ID:
Result ValueComponent Detection Limit Units
G0342-N-R GC/MS Analysis for Organic Bromine Compounds (IEC 62321 Edition 1 111/116/FDIS)
Polybrominated biphenyl (PBB) / 1 10 * ppm
Polybrominated diphenyl ether (PBDE) / 1 10 * ppm
G0344-N-R RoHS ICP Elemental Analysis for Cd, Pb, and Hg
Cadmium (Cd) / 1 1 * ppm
Lead (Pb) / 1 1 30000 ppm
Mercury (Hg) / 1 30 * ppm
G0345-N-R Hexavalent Chromium by UV-VIS (EC Method)
Hexavalent chromium (Cr+6) / 1 1.0 * ppm
G0315-N-R Gas Chromatography / Mass Spectrometry (GC/MS), Direct Injection Liquids
Dibutyl phthalate (DBP) 10 * ppm
Benzyl butyl phthalate (BBP) 10 * ppm
Diisobutyl phthalate (DIBP) 10 * ppm
Di(2-ethylhexyl)phthalate (DEHP) 10 * ppm
* = Analysis revealed that the analyte was not found at or about the detection limit
These results were obtained by following standard laboratory procedures and are only representative of the sample as received by the laboratory.
The liability of AIR LIQUIDE - BALAZS NanoAnalysis ("Balazs") should not exceed the amount paid for this report. In no event shall Balazs be liable for
special of consequential damages. Client agrees not to use Balaz's name in reporting results obtained from tests performed by Balazs written consent
as to such use. Report shall not be reproduced except in full, without the written permission of Balazs.
Page 4 of 6
Air Liquide Electronics U.S. LP
46409 Landing Parkway, Fremont CA 94538
Telephone (510) 624-4000 Fax (510) 657-2292
MS JULES POISSON
TELEDYNE-DALSA SEMICONDUCTOR
Release:
501266P.O.:
9-Nov-17Order Date:
Report Date:
17-11505Work Order:
Approved By: Tiffany Wilkus
ORGANIC LAB MANAGERTitle:
11-Dec-17
Photo 1. Optical Image of 184021 Wafer 1 (200mm Wafer)
Photo 2. Optical Image of 185114 Wafer 21 (150mm Wafer)
These results were obtained by following standard laboratory procedures and are only representative of the sample as received by the laboratory.
The liability of AIR LIQUIDE - BALAZS NanoAnalysis ("Balazs") should not exceed the amount paid for this report. In no event shall Balazs be liable for
special of consequential damages. Client agrees not to use Balaz's name in reporting results obtained from tests performed by Balazs written consent
as to such use. Report shall not be reproduced except in full, without the written permission of Balazs.
Page 5 of 6
Air Liquide Electronics U.S. LP
46409 Landing Parkway, Fremont CA 94538
Telephone (510) 624-4000 Fax (510) 657-2292
MS JULES POISSON
TELEDYNE-DALSA SEMICONDUCTOR
Release:
501266P.O.:
9-Nov-17Order Date:
Report Date:
17-11505Work Order:
Approved By: Tiffany Wilkus
ORGANIC LAB MANAGERTitle:
11-Dec-17
These results were obtained by following standard laboratory procedures and are only representative of the sample as received by the laboratory.
The liability of AIR LIQUIDE - BALAZS NanoAnalysis ("Balazs") should not exceed the amount paid for this report. In no event shall Balazs be liable for
special of consequential damages. Client agrees not to use Balaz's name in reporting results obtained from tests performed by Balazs written consent
as to such use. Report shall not be reproduced except in full, without the written permission of Balazs.
Page 6 of 6