Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone 1
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
Table of Contents 2A. Scope 3B. The GeoLog Measuring Head. 3C. Screen Functions 41) Main backup depth screen 42) Depth Reset 43) Depth Adjust 44) Ground Level setting 55) Downhole Depth 66) Depth Increase 67) Depth Decrease 68) Reset Adjust 69) Back-up Depth 610) Depth Adjustment 611) Cable Size 712) Drum Counter 813) Drum Rotation Counter 814) Hydraulic Temperature 915) Main Screen 10
D. The Encoder Runs at 5-30 VDC with a Maximum of 100A 111) Industrial Encoder Specification 112) Scancon Industrial Encoders Type 2QEX 123) Scancon Ordering Code 16
2
Table of Contents
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
A. Scope
The Beijer Cluster Gauge allows the wireline truck operator to have a backup depth that is encoder based. The Scancon is a 300-pulse-per-revolution encoder that runs from 5- to- 30VDC (voltes direct current). The Beiger Gauge drives this encoder at 24VDC. The software on the Beijer screen enables the operator to set surface depth and downhole depth easily.
B. The GeoLog Measuring Head.
Your model may vary from the Geolog 20-20 2-ft Measuring Head shown below.
3
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
C. Screen Functions
1) Main backup depth screen To operate the screen for surface or downhole depth control, begin with the main (default) Back-Up Depth screen (If your screen is not here, touch the Back-Up Depth icon located on the top right corner of the screen; however, your default screen may still look different).2) Depth Reset
When setting the depth at ground level, touch the Depth Reset depth icon at the top left corner of the screen.3) Depth Adjust
When setting the depth downhole, touch the Depth Adjust.
4
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
4) Ground Level setting When at ground level (GL), touch the Depth Reset button to set the Back-Up Depth counter to zero (0.0).
5
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
5) Downhole Depth To adjust downhole depth, touch the Depth Adjust icon on the main screen.6) Depth Increase
Touch the Depth Inc icon to increase the Back-Up Depth counter number.7) Depth Decrease
Touch the Depth Dec icon to decrease the Back-Up Depth counter.8) Reset Adjust
Touching the Reset Adjust icon will return the screen setting to its original downhole depth as long as the Enter button has not been touched. The Reset Adjust button will not reset to the original setting if the operator touches the “Enter” button.9) Back-up Depth
Touching the Depth Inc icon will increase the Back-Up Depth counter number and will speed up exponentially the longer the button is held (slower to faster). Conversely, touching the Depth Dec icon will decrease the Back-Up Depth counter number. This button also speeds exponentially. 10) Depth Adjustment
When the depth adjustment is correct, touch Enter to set the depth counter.
6
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
11) Cable Size The cable size is also selectable in this screen. The line sizes available are 7/32, 1/4, 9/32 and 5/16. Select the appropriate line size and touch Enter.
7
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
12) Drum Counter Touch the Back-Up Depth icon on the upper right corner to go to the main Back-up Depth screen. The Drum Counter icon will be displayed on the bottom left corner of the Back Up Depth screen.
13) Drum Rotation Counter If the Drum Rotation icon on the right of the screen is selected, the Drum Rotation Counter (DRC) screen will be displayed and the Back Up Depth icon will be located on the bottom right side of the screen.
8
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
14) Hydraulic Temperature Touch the Hyd icon to display the hydraulic system pressure, charge pressure, hydraulic temperature and air pressure. The Back Up Depth will be minimized in the bottom right corner.
9
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
15) Main Screen Touch the Back-Up Depth icon to return to the main depth screen.
10
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
D. The Encoder Runs at 5-30 VDC with a Maximum of 100A. 1) Industrial Encoder Specification
See the Industrial Encoder Specification in the next section of this manual.
11
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
Rev. 1.5 18 Apr. 2013 Scancon Tranevang 1 3450 Allerød Denmark p.1
Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk
Oil & Gas / Heavy Industry
Type 2QEX
Mechanical Specifications
Material: Housing: Aluminum Cap: Aluminum Shaft: Stainless Steel (AISI 303)
Weight: Encoder: Approx. 350 gr (12.35 oz)
Bearing Life: > 1.9 x 1010revolutions at rated load
Shaft Speed: 6,000 rpm max.
Starting Torque: < 0.01 Nm (1.4 oz-in) at 25° C
Mass Moment of Inertia: 4 gcm (5.66 x 10-5 oz-in-sec )
Shaft Loads: Axial 50 N (11.25lbs) max. Radial 100 N (22.50lbs) max.
Electrical Specifications Code: Incremental Resolution: 1 to 12,500 ppr (pulses per rev.)
Supply Voltage: 4.5 Vdc min. to 30 Vdc max. at 45 mA max. (no load)
Output Voltage: Low: 500 mV max. at 10 mA High: (Vin – 0.6) at -10 mA (Vin – 1.3) at -25 mA
Output Current: 30 mA max. Load per output channel
Frequency Response: 300 kHz max.
Output Format:
Two channel (A, B) quadrature with Index (Z) and optional complementary (A-, B-, Z-) outputs
Phase Sense: A leads B counterclockwise (CCW) from the shaft end of the encoder
Index: 90° +/- 18° electrical
Accuracy: +/- 0.8 arc-min.
Output:
ASIC Push-pull and Differential OL7272 Push-pull and Differential Line Driver 26C31 Differential Line Driver 5V imput / 5V output
Electrical Protection:
Output short circuit protected. Reverse polarity protected for ASIC outputs only. (not for OL7272 or 26C31 outputs)
Noise Immunity:
Tested to EN50081-1 and EN 50082-2 (heavy industrial) for Electro Static Discharge (ESD), Radio Frequency Interference (RFI), Electrical Fast Transients (EFT), and Conducted and Magnetic Interference
Environmental Specifications Operating Temp.: -40° to +85° C
Storage Temp.: -40° to +85° C
Shock: 100 G @ 11 ms
Vibration: 10-2000 Hz@10 G
Bump: 10 G @ 16 ms (1000 x 3 axis)
Humidity: 98 % RH without condensation
Enclosure Rating:
IP 67 / Nema 6 (approx.) IP 66 / Nema 6 (approx.) option IP 65 / Nema 4 (approx.) option 22 micron anodization
Connection Options
Cable: 8 leads (0.14 mm-2, 26 AWG) twisted pairs; shielded
Connectors: 6-pin Mil radial 7-pin Mil radial 10-pin Mil radial
Ex nA Proof – Shaft Encoder – Ø 50 mm
2.5 in. or 2.63 in. Square Mount
Shaft: Ø 1/4 inch to 10 mm
Shaft Loads to 100 N (22.5 lbs)
IP 67 Environmental Protection
22 micron anodization “seawater-proof”
EN 60079
2) Scancon Industrial Encoders Type 2QEX
12
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
Rev. 1.5 18 Apr. 2013 Scancon Tranevang 1 3450 Allerød Denmark p. 2 Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk
Type 2QEX
Output waveform Disk Resolutions (pulses per revolution)
Channel tolerance 180 e°+/- 36 e° Phase difference tolerance 90 e°+/- 18 e° Z channel tolerance 180 e°+/- 36 e°
Mechanical Dimensions
Certifications
ATEX: Certificate No.: ITS08ATEX42972 II 3 G Ex nA IIC T5 and II 3 D Ex tD A22 IP64 T95°C - 40°C ≤ Tamb ≤ +85°C
GOST: Certificate No.: POCC DN.Б05.B03721 No. 0466143 II 3 G Ex nA IIC T5 and II 3 D Ex tD A22 IP64 T95°C - 40°C ≤ Tamb≤ +85°C
ISO 9001 : 2008 Certificate Registration No.: 44 100 111616 Report No: 3508 5281
Flange A Option
1 30 100 500 2000 2 32 125 600 2500 5 36 150 635 3000 6 40 180 720 3600 8 50 200 800 4000
10 60 250 1000 4096 15 64 300 1024 5000 16 75 360 1131 9000 20 80 400 1250 10000 25 90 455 1500 12500*
* Operating temperature: - 20°C to 50°C
13
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
Rev. 1.5 18 Apr. 2013 Scancon Tranevang 1 3450 Allerød Denmark p. 3 Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk
Type 2QEX
Flange A Option
Flange B Option
14
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
Rev. 1.5 18 Apr. 2013 Scancon Tranevang 1 3450 Allerød Denmark p. 4 Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk
Type 2QEX
Standard Cable
Standard Output
Differential Output
Channel Wire Color Wire Color A Pink Pink
A - Gray* Gray B Green Green
B - Yellow* Yellow Z White White
Z - Brown* Brown Vsup Red Red GND Blue Blue
* Gray, Yellow, and Brown are internally connected as Ground
GND = Circuit Ground
Output Terminations
6-pin Mil 7-pin Mil 10-pin Mil
Standard Output
Standard Output
Optional Standard
Output *
Optional Differential Output *
Differential Output
Optional Differential Output *
Pin Channel Channel Channel Channel Channel Channel
A GND Ch. A Ch. A Ch. A Ch. A Ch. A B Vsup Ch. B Ch. B Ch. B Ch. B Ch. B C Ch. Z Ch. Z NC Ch. A - Ch. Z Ch. A - D Ch. B Vsup Vsup Vsup Vsup Vsup E Ch. A NC NC Ch. B - NC Ch. B - F NC GND GND GND GND GND G NC NC Shield NC Shield H Ch. A - NC I Ch. B - NC J Ch. Z - NC
GND = Circuit Ground Shield = Case Ground
* ID number required
15
Back-Up Depth Counter Manual
Synergy Industries12963 Oak Grove Rd. SouthBurleson, Texas [email protected] phone
Rev. 1.5 18 Apr. 2013 Scancon Tranevang 1 3450 Allerød Denmark p. 5 Tlf +45 48 17 27 02 Fax +45 48 17 22 84 www.scancon.dk
Type 2QEX
2QEX-A - - AL - - - - - - -
Pulses per Revolution
See table
Material Aluminum AL
Output Standard N Differential D 26C31 Line Driver 5V only L* OL 7272 Line Driver M* * Not reverse polarity protected
Shaft Diameter x Length 1/4 in. x 20 mm 1/4 - 20 3/8 in. x 21 mm 3/8 - 20 3/8 in. x 22.5 mm 3/8 - 22 8 mm x 20 mm 08 - 20 10 mm x 20 mm 10 - 20
IP Rating IP 65 65 IP 66 66 IP 67 67
Cable Length Standard is 1 meter 01 Specifylength XX No cable 00
Cable Takeout
or Connector
Cable Side (Radial) takeout S Connector MIL 6 pins C6 MIL 7 pins C7 MIL 10 pins C10
Flange 2.50 in. square A 2.65 in. square B
Example: 2QEX – A – 120 – AL – D – 3/8 – 22 – 67 – 00 – C7 – A
Ordering Code
3) Scancon Ordering Code
16