TRAINING MANUAL FOR TRAINING PURPOSES ONLY B767-3S2F ATA 36-00 Page - 1 5/21/13 EFF - ALL PNEUMATICS CH 36

B767 ATA 36 Student Book

Embed Size (px)

DESCRIPTION

B767 ATA 36 Tranining Manual. Contains Operation of the Pneumatic System on the B767.

Citation preview

Page 1: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 1 5/21/13 EFF - ALL

PNEUMATICS

CH 36

Page 2: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 2 5/21/13 EFF - ALL

ATA 36 PNEUMATIC SUPPLY TABLE OF CONTENTS

GENERAL…………………………….……………………… ……………..............4

COMPONENT LOCATION ………………………………….….…………............6

CONTROL AND INDICATION………………………………............... ………….8

AIR SUPPLY DISTRIBUTION SYSTEM………………….….………….............10

ENGINE AIR SUPPLY SYSTEM...…………………………...………….............12

ENGINE AIR SUPPLY LOCATIONS ...................………….…………..............14

AIR SUPPLY PRESSURE SWITCHES……………….…….….………..............16

ENGINE AIR SUPPLY SYSTEM………………………….……………...............18

HIGH PRESSURE SYSTEM………………………….…….……………..............20

ENGINE BLEED CONTROL LOGIC…….............………….……….…………...22

ENGINE MANIFOLD PRESSURE CONTROL.........................................……. 24

HPSOV AND PRV……………………………………….……...…….…............... 26

BLEED LIGHT AND MESSAGES............……………………….…………...…...28

INTERMEDIATE PRESSURE CHECK VALVE………….……………...............30

FAN AIR SYSTEM...........……………………………………….………...……….32

AIR SUPPLY PRECOOLER……………………………………………............... 34

PRESSURE REGULATING AND SHUTOFF VALVE……………...…..............36

APU SHUTOFF VALVE CONTROL.................................................................38

APU SHUTOFF VALVE CONTROL..................................................................40

ISOLATION AND ISOLATION CHECK VALVES..............................................42

ISOLATION VALVE CONTROL........................................................................44

AIR SUPPLY INDICATION...............................................................................46

AIR SUPPLY DUCT PRESSURE INDICATION...............................................48

DUCT PRESSURE TRANSMITTERS...............................................................50

OPERATIONAL CHECKS.................................................................................52

GROUND CHECKS..........................................................................................54

Page 3: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 3 5/21/13 EFF - ALL

STUDENT NOTES:

Page 4: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 4 5/21/13 EFF - ALL

PNEUMATIC SYSTEM - GENERAL

Purpose

The pneumatic system provides air to the following users:

• Air Conditioning • Cargo Heating • Wing Anti-ice • Engine Nose Cowl Anti-ice • Engine Starting • Hydraulic Reservoir Pressurization • Total Air Temp Probe • Air Driven Hydraulic Pump (ADP)

System Description

The system is a supply and distribution system. It consists of three different types of air sources; engine, APU and ground air that are interconnected to the user systems by a distribution system.

This course will cover the pneumatic system in general, then in five basic sections: Engine Air Supply, APU Air Supply, Ground Air Supply, Air Supply Distribution and Air Supply Indication.

Page 5: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 5 5/21/13 EFF - ALL

PNEUMATIC SYSTEM - GENERAL

Page 6: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 6 5/21/13 EFF - ALL

PNEUMATIC SYSTEM - COMPONENT LOCATION

Location

The components of the pneumatic system are located throughout the airplane.

The control, monitoring and indication parts of the system are located in the flight compartment and main equipment center. The four basic sections of the pneumatic system are located as follows:

Engine air supply system is situated in three areas: on the engine, between the engine and strut and within the engine strut.

APU air supply system is situated between the APU firewall and aft pressure bulkhead.

Ground air supply system is situated forward of the left air conditioning pack which is forward of the left main wheel well.

Air supply distribution system extends from engine to engine and to the APU firewall.

Page 7: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 7 5/21/13 EFF - ALL

PNEUMATIC SYSTEM - COMPONENT LOCATION

Page 8: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 8 5/21/13 EFF - ALL

PNEUMATIC SYSTEM - CONTROL AND INDICATION

Description

The system incorporates an electronic monitoring/testing system (air supply bite module, E-3) and an electronic control circuit (bleed air control cards, P50) for the engine air supply system. One control panel is provided in the flight compartment on the P5 overhead for the pneumatic system. The control panel incorporates control switches, annunciator lights and a duct pressure gauge. EICAS provides messages on its upper display (CRT) that are associated with the annunciators on the control panel.

EICAS also provides duct pressure information on the ECS/MSG page, and as an option, temperature information on the engine bleed air just before it enters the air supply distribution system (precooler out).

Interfaces

The pneumatic system interfaces with EICAS. The system provides and/or receives information from the air conditioning and the nose cowl TAI systems.

Page 9: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 9 5/21/13 EFF - ALL

B767-300 CH 36-00 TRAINING MANUAL PAGE - 9 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

PNEUMATIC SYSTEM - CONTROL AND INDICATION

Page 10: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 10 5/21/13 EFF - ALL

PNEUMATIC SYSTEM - AIR SUPPLY DISTRIBUTION SYSTEM

General Operation

The pneumatic system requires minimum crew inputs to operate the system. The engine air supply section is enabled by placing the engine bleed air switchlight to the OPEN position (flow bar displayed). The system is then controlled automatically, providing temperature and pressure regulated air to the various user systems as shown on the graphic.

The APU air supply section is also automatically controlled, if it is enabled by placing the APU bleed air switchlight to the OPEN position (flow bar displayed). Once enabled, the APU air supply system will automatically supply air when required to the distribution system.

Operation of the ground air supply system requires a ground air cart(s) to be connected to the connector(s). The air flow and temperature is controlled externally at the ground cart(s).

The operation of the distribution system consists of selecting the position of the three isolation valves: left, right and center. For normal operation, the left and right valves are selected CLOSED and the center valve is selected OPEN. In this configuration, air from the engines would be available at all times to the center part of the distribution system through the bypass check valves.

The distribution system provides air to several user systems but the most important is the air driven hydraulic pump. Additional information on operation will be provided for each of the four basic sections of the pneumatic system, engine air supply, APU air supply, ground air supply and the air supply distribution system, in the following sections of this training manual.

Page 11: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 11 5/21/13 EFF - ALL

PNEUMATIC SYSTEM - AIR SUPPLY DISTRIBUTION SYSTEM

B767-300 CH 36-00 TRAINING MANUALPAGE - 11 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

14THSTAGEBLEED

TAT PROBE

Page 11

Page 12: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-10 Page - 12 May, 21,2013 EFF - ALL

PNEUMATIC SUPPLY - ENGINE AIR SUPPLY SYSTEM

Purpose

The engine air supply system selects engine bleed air from the High Pressure or Intermediate stage. Air from the engine is temperature and pressure regulated and is ducted to the air supply distribution system as the pneumatic source.

System Description

Two independent and identical systems are provided, one for each engine. Each system consists of pneumatically controlled valves, electrically enabled pneumatically operated controllers, sensors and pressure and temperature switches. These components function automatically to control the source, pressure and temperature of the engine bleed air. The system is divided into operating functions. These functions are Bleed source control, temperature control, reverse flow control, pressure control and overheat/over-pressure protection. The components that are incorporated into each of the basic functions are as follows:

Bleed Source Control

The source control components are the high pressure shutoff valve (HPSOV), which is pneumatically controlled by the high pressure shutoff valve controller (HPSOVC).

Temperature Control

There are three components to control the bleed air temperature. These are the precooler, fan air valve and the fan air sensor. The pressure regulating and Shutoff Valve (PRSOV) as a secondary function will regulate temperature.

Reverse Flow Control

The 8th stage check valve provides reverse flow control for the 8th stage. The PRSOV provides reverse flow control for the distribution system.

Pressure Control

Pressure control is provided by the Pressure Regulating Valve (PRV) for the engine manifold area. The PRSOV controls engine bleed pressure for the air supply distribution system.

Overheat and Overpressure Protection

A pressure switch and a temperature switch provide protection. The switches, if activated, will affect operational functions.

Page 13: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 13 May, 21,2013 EFF - ALL

PNEUMATIC SUPPLY - ENGINE AIR SUPPLY SYSTEM

Page 14: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-10 Page - 14 May, 21,2013 EFF - ALL

PNEUMATIC SUPPLY - ENGINE AIR SUPPLY LOCATIONS

Each engine air supply system consists of the following components:

• Pneumatic Ducts • Intermediate Pressure Check Valve • High Pressure Shut-Off Valve (HPSOV) • High Pressure Controller • Pressure Regulator Valve (PRV) • PRV Controller • Air Supply Precooler • Air Modulating Valve • Fan Air Temperature Sensor • Overheat Temperature Switch • Pressure Regulating And Shut-Off Valve (PRSOV)

Page 15: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 15 May, 21,2013 EFF - ALL

PNEUMATIC SUPPLY - ENGINE AIR SUPPLY LOCATIONS

Page 16: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-10 Page - 16 May, 21,2013 EFF - ALL

PNEUMATIC SUPPLY - AIR SUPPLY PRESSURE SWITCHES Description

The Air Supply Over-pressure Switch (114 psi) and PRV Exit Sensor monitor engine bleed air out of the PRV and is measured down stream of the precooler.

The PRV Exit Sensor provides information for BITE only.

Location

The Air Supply Over-Pressure Switch and The PRV Exit Sensor are located in the leading edge of the wing inboard of the engines.

Page 17: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 17 May, 21,2013 EFF - ALL

PNEUMATIC SUPPLY - AIR SUPPLY PRESSURE SWITCHES

Page 18: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 18 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - ENGINE AIR SUPPLY SYSTEM

System Interface

The bleed air control card provides PRSOV position information to the flow control cards of the air conditioning system. It also provides the same information to the APU air supply valve control circuit.

The control circuit for the nose cowl TAI system inputs the bleed air control card to enable the PRV controller if the following is true: there is no strut OVHT (see fire protection), and the engine is not being started. PRV opening can occur for cowl anti-ice with an activated overheat switch. The HPSOV will remain closed.

General Operation

The system is enabled by placing the engine bleed switch, on the bleed air supply control panel (P5) to ON. This enables the PRSOV, PRV controller and the HPSOV controller. Air is bled from the engine high pressure compressor at the 14th stage bleed ports or the 8th stage bleed ports. The HPSOV controller uses a predetermined schedule, which is dependent on High stage pressure and airplane altitude.

At low power settings, the High stage provides the air, and at high power settings, 8th stage is selected. The bleed air control card monitors the HPSOV through the valve's closed limit switch. The card will activate the HPSOV fail indication if the valve is not closed when commanded because of one of the following: High stage is greater than 127 psig, the strut OVHT detection system senses an OVHT (greater than 300 F, 149 C) or the engine bleed air OVHT switch activates (490 F, 254 C). At low power settings, when air is bled off High stage, the 8th stage (intermediate pressure) check valve prevents flow from the High stage into the 8th stage.

The PRV and controller regulates the pressure in the engine manifold so that it does not exceed 97+5/-12 psig. Engine bleed air, after flowing through the PRV, flows through the precooler which is part of the primary temperature control section of the engine bleed air system.

The precooler has the engine bleed air flowing towards the PRSOV, and cooling engine fan air flowing from the fan air (modulating) valve, through the precooler then overboard. Engine bleed air and cooling fan air are separated by cooling fins. The amount of fan air (cooling air) that flows through the precooler is

controlled by the fan air valve whose position is controlled by the fan air temperature sensor. The sensor is set to control the bleed air temperature to 400° F +/- 30° F.

The PRSOV regulates the pressure of the air entering the distribution system to 40 +/- 10 psig. The valve also has reverse flow control that will close the valve if engine manifold pressure is less than the distribution system pressure. The valve incorporates a temperature control circuit that will regulate flow if the temperature of the bleed air exceeds 450° F (232 C).

Overpressure and overheat switches monitor engine bleed air at the outlet of the precooler.

A pressure of 114 psig or greater in the engine manifold will activate the engine air supply overpressure switch which will activate the BLEED indication circuit (BLEED light and EICAS message ("L(R) ENG PRV") if the PRV is not closed.

If bleed air temperature exceeds 490° F +10°/ -5° F, the engine air supply overheat switch will activate and provide a signal to the bleed air control card.The card will output an OVHT signal for indication and another signal to command the PRV and HPSOV controllers to OFF. The circuit may be reset by cycling the engine bleed switch. The BLEED indication circuit will also be acti- vated anytime the PRV or HPSOV are commanded closed and are not closed after a short delay. The air supply bite module monitors the engine air supply system but does NOT provide any inputs for the operation or control of the system.

Page 19: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 19 5/21/13 EFF - ALL

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 19 2/27/13 EFF - ALL

00-63 HC003-767B TRAINING MANUALPAGE - 19 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

PRECOOLER OUT TEMP >490°

CF6-80C2

114PSI

PRV OR HPSOV OPEN WHEN COMMANDED CLOSED

BLEEDAIR CARD

PNEUMATIC SUPPLY - ENGINE AIR SUPPLY SYSTEM

PNEUMATIC SUPPLY - ENGINE AIR SUPPLY SYSTEM

Page 20: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 20 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - HIGH PRESSURE SYSTEM

Description

The high pressure controller opens and closes the high pressure shutoff valve. The controller is remotely located to avoid harmful temperatures and vibration. The controller is located on the upper left hand side of the engine just aft of the fan cowl.

The high pressure controller consists of a cast aluminum body, altitude biased pneumatic switch, internal sensing diaphragm, and a latching shutoff solenoid. Four pressure switches provide BITE LOGIC which will monitor operation of the high pressure controller.

Operation

The solenoid is commanded to the AUTO or OFF position by signals from the bleed air control card. In AUTO, the HPSOV controller allows the high pressure shutoff valve to operate depending upon high stage pressure. At low altitudes the switchover pressure is 105 psi. Below 105 psi the pneumatic system operates on high stage pressure and above105 psi on intermediate stage pressure. An aneroid changes the switchover pressure linearly from 105 psi at 27,000 feet to 77 psi at 41,000 feet.

In the event of electrical power loss, the solenoid remains in the last commanded position.

BITE Switches

The air supply BITE module monitors the operation of the controller and thevalve with BITE pressure switches and position switches. The switches do not have an effect on the operation of the controller or valve. The switches are for indication only.

Physical Description

The high pressure shutoff valve operates in response to pneumatic servo pressure from the high pressure controller. The HPSOV is located on the right side of the engine and the Controller is on the upper left side of the engine. The valve is spring loaded to close.

The high pressure shutoff valve is a 5.5" disk valve. A half-area pneumatic actuator positions the valve. A piston-type crank drives the disk through a link and crank.

The valve shaft extension is hex shaped to allow manual positioning of the valve. A lock pin, normally stored in the actuator cap, must be used to dump actuator servo pressure and lock the valve in the closed position. Failure to use the dedicated lock pin can result in damage to the shutoff valve diaphragm.

Page 21: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 21 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - HIGH PRESSURE SYSTEM

Page 22: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 22 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - HIGH PRESSURE CONTROL

Operation/Control Sequence

The high pressure controller and the PRV controller are activated to Auto (ON) by the engine bleed air supply switch, or the engine nose cowl TAI system. The controllers will be inhibited and latched off if an overheat occurs in the engine strut or in the engine bleed air manifold. There is one exception; the PRV controller will not be affected by an OVHT in the engine bleed air manifold when commanded to AUTO by the activation of the engine nose cowl TAI system.

Reset of the latching circuits may be accomplished after the overheat condition no longer exists by cycling the engine bleed air switch OFF then to ON.

The PRV controller is commanded OFF during the engine start sequence for both engines if the airplane is on the ground and the APU is providing the air. Otherwise only the controller for the engine being started will be commanded OFF.

The high pressure shutoff valve's controller (HPSOVC) will be automatically commanded to Auto (ON) during engine start. This will provide pneumatic pressure to the Pressure Regulating Valve (PRV) to ensure positive closure.

Backup Operation

If a failure occurs in the high pressure control system an indication will be provided. Depending on the faulty component(s), the air supply bite module will record which component is faulty. Also, depending on the fault, the control circuit (bleed air control card) will take action automatically to protect the engine air supply system. The action can be in the form of activating a message on EICAS that requires crew action, or by commanding the PRV, HPSOV, & PRSOV to OFF. The following describes the engine bleed air protection circuit by listing the possible messages and annunciator lights.

BLEED Light

The BLEED light will illuminate if either the HPSOV or the PRV is open when commanded closed.

ENG PRV message, BLEED light

The level "B" message, "L ENG PRV" will be activated if the PRV is commanded closed and does not close within five seconds, or if engine manifold pressure exceeds 114 PSI and the PRV is open.

ENG HPSOV message, BLEED light

A level "B" EICAS message “L ENG HPSOV" is associated with the High Pressure Shutoff Valve (HPSOV). The message and "Bleed" light are activated by the bleed air control card.

The EICAS message and the "Bleed" light will be activated for the following:

• HPSOV open and High stage pressure greater than 127 PSIG (PPH switch in the HPSOV controller).

• HPSOV commanded to close and does not close. • The Air Supply Bite Module will indicate if the HPSOV or the HPSOV

controller is faulty.

STRUT DCT LEAK message, DUCT LEAK light

The "L STRUT DCT LEAK" level "B" EICAS message and the DUCT LEAK light are activated and latched by the bleed air control card to indicate a strut leak (overheat). The bleed air control card also commands the HPSOV and PRV to OFF for this condition. Reset after cool down, by cycling the ENG BLEED switch. The air supply bite module does not monitor the strut duct leak circuit.

L ENG BLD OVHT Message, OVHT Light

The L ENG BLD OVHT level "C" message and the OVHT light are activated and latched by the bleed air control card when the air supply OVHT switch activates. In addition the card will command the PRSOV to OFF,HPSOV controller to OFF under all conditions unless Thrust Reversers are selected upon landing and a Strut Overheat condition does not exist. The PRV controller will be commanded to OFF if it is not commanded to AUTO by the ENGINE COWL TAI system. closed. The air supply bite module, if interrogated, will indicate the faulty components.

Page 23: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 23 5/21/13 EFF - ALL

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 23 2/27/13 EFF - ALL

00-63 HC003-767B TRAINING MANUALPAGE - 23 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

> 490° F

L PRV NOT CLOSED AT 114 PSI

L HPSOV NOT CLOSED AT 127 PSI

114 PSI

OFFAUTO14TH

> 127

>114PSI

LEFT BLEED AIR CONTROL CARD

PNEUMATIC SUPPLY - HIGH PRESSURE CONTROL

PNEUMATIC SUPPLY - HIGH PRESSURE CONTROL

CF6-80C2

Page 24: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-10 Page - 24 May, 21,2013 EFF - ALL

PNEUMATIC SUPPLY - ENGINE MANIFOLD PRESSURE CON-TROL

Purpose

The pressure regulating valve (PRV) in conjunction with the PRV controller regulates downstream (engine pneumatic manifold) pressure to a level compatible with downstream components and ducting.

Location

The PRV is just upstream of the precooler on the upper right hand side of the engine. The PRV controller is mounted on the top left side of the engine just aft of the HPC. PRV

The PRV is a 5.5 inch butterfly valve and is spring loaded closed when air pressure is removed. The PRV operates in response to control pressure from the PRVC. The HP Valve and the PRV are interchangeable.

PRV Controller

The PRV controller is a solenoid activated (latching type) pneumatic controller. It includes all the pneumatic-mechanical and electrical-mechanical control functions for the PRV.

Operation

The PRV and PRV controller operate together to control the engine manifold pressure to 97 +5/-12psig.

Page 25: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 25 May, 21,2013 EFF - ALL

ACTUATOR SERVO PRESSURE

REGULATED

ELECTRICAL PRESSURE PORT CONNECTOR (DOWNSTREAM OF PRV)

_ SOLENOID

GE CF6 - 80C2 - 11 O'CLOCK HPC CASE

FILTER SUPPLY

PRESSURE PORT

ACTUATOR (UPSTREAM OF PRV)

PRESSURE PORT

(TO PRV)

B767-300 CH 36-00 TRAINING MANUAL PAGE - 25 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

PRV AND PRVC

PNEUMATIC SUPPLY - ENGINE MANIFOLD PRESSURE CONTROL

Page 26: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 26 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - HPSOV AND PRV

Ground Handling

The High Pressure Shutoff Valve (HPSOV) and the Pressure Regulating Valve are identical and interchangeable. Thus the deactivation procedures for each valve is exactly the same. The airplane operating procedures (crew procedures) are different for each valve. For details see the recommended MEL.

The valves may be deactivated to the locked CLOSE position only. The right thrust reverser must be opened to gain access to either valve. The valves may be deactivated (locked close) by removing the locking pin from its stowed position in the actuator.

Insure the valve is fully closed (position indicator). If it is not closed, rotate the manual override hex nut until the position indication aligns with the CLOSE mark on the valve. Install the locking pin through the locking crank and into the valve.

CAUTION: IT IS NECESSARY TO LOCK THE THRUST REVERSER IN THE FORWARD THRUST POSITION IF EITHER THE PRV OR THE HPSOV IS DEACTIVATED. REFER TO THE MEL.

To activate, reverse the above procedures. It is very important to insure the locking pin is properly reinstalled in the stowed position. If it is not installed completely, the valve will not operate correctly because the actuator pressure will be vented to ambient around the pin.

Page 27: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 27 5/21/13 EFF - ALL

POSITION SWITCHES ELECTRICAL

CONNECTIONS

VALVE INLET

HPSOV PRV

HEX FOR MANUAL

OPERATION

LOCKING PIN

HOLE

LOCKING CRANK VALVE ___________

ACTUATOR

ACTUATOR SERVO

PRESSURE

LOCKING PIN (STOWED POSITION)

VALVE OUTLET

B767-300 CH 36-00 TRAINING MANUAL PAGE - 27 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

PNEUMATIC SUPPLY - HPSOV AND PRV

Page 28: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 28 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - BLEED LIGHT AND MESSAGES

Review Pneumatic Supply Bleed Normal Parameters

Engine air supply system controls the pressure, temperature, and flow of bleed air: • 8th stage intermediate air • 14th stage for high pressure

When high stage pressure increases to 105PSI (+/-5) the HPC closes the HPSOV.

The PRV keeps air pressure to 97PSI (+5/-12) before entering the precooler. The precooler is an air-to-air heat exchanger that uses fan air for cooling.

The Fan Air Temperature Sensor works to keep precooler output temps at 400F (+/_30F).

The PRSOV contains a temp controller which keeps bleed air temps below 490F. At 442F (+/-7) PRSOV moves toward closed. At 490F PRSOV goes fully closed. The PRSOV also contains a pressure controller which keeps downstream pressure at 40PSI (+/-10).

Overpressure switch condition 114 psi.

Abnormal Conditions for Bleed Light and Messages

Conditions illustrated in graphic for Bleed Light. Message will specify which valve is responsible.

Page 29: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 29 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - BLEED LIGHT AND MESSAGES

Page 30: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 30 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - INTERMEDIATE PRESSURE CHECK VALVE

Physical Description

The intermediate pressure check valve is an in-line check valve. The valve consists of an outer shell, inner shell with strut supports, piston guide and a sliding valve plate/piston assembly.

The duct in which the valve mounts is a 5.5 inch diameter duct. An arrow on the body of the valve indicates direction of flow.

When the pressure upstream of the intermediate check valve becomes greater than that downstream, the valve plate and attached piston of the intermediate pressure valve, slide open. The piston guide in the inner shell guides the plate/piston assembly when moving. When the pressure upstream of the intermediate pressure check valve becomes less than that downstream, the plate/piston assembly slide closed. This prevents reverse flow through the valve.

The check valve is located on the engine at the 3 o'clock position. Removal of the check valve requires opening of the right T/R.

Page 31: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 31 5/21/13 EFF - ALL

VALVE PLATE

SUPPORT STRUT

INNER SHELL OUTER SHELL

_______________________

_______________

FROM 8TH STAGE BLEED AIR SOURCE

VORTEX GENERATOR FLOW

VALVE PLATE

(CLOSED)

FRONT VEIW VALVE PLATE (OPEN)

FROM HIGH STAGE PISTON GUIDE BLEED AIR SOURCE

VALVE PISTON INNER SHELL

ENGINE MANIFOLD DUCTING OUTER SHELL

INTERMEDIATE PRESSURE CHECK VALVE

B767-300 CH 36-00 TRAINING MANUAL PAGE - 31 - FOR TRAINING PURPOSES ONLY

PNEUMATIC SUPPLY - INTERMEDIATE PRESSURE CHECK VALVE

Page 32: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 32 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - FAN AIR SYSTEM

Sensor Description

The fan air temperature sensor mounts in the duct between the precooler and the PRSOV (pressure regulator and shutoff valve). The sensor body contains a lever and crank operated by a bimetallic temperature probe. The temperature probe projects into the duct. A ball poppet regulator valve and air filter are located in the pressure supply line of the sensor unit. Two pressure switches and a temperature sensor provide information to the BITE system.

Sensor Operation

The fan air temperature sensor modulates the servo pressure that controls the fan air valve. The valve is spring loaded open. With the system pressurized the valve then closes.

Increasing temperature causes the poppet to open, servo pressure then vents and the fan air modulating valve opens. Below 370° F (188° C), all temperature bias is removed and the valve remains closed.

At 370° F the valve begins to open and when the temperature reaches 430° F (221° C) the valve is full open.

Valve Description

The fan air modulating valve is a nine-inch diameter pneumatically actuated disk valve. The valve mounts at the cooling air inlet to the precooler. The valve consists of a half-area actuator spring-loaded to the open valve position. The actuator contains a diaphragm-operated poppet attached to a spring compensated lever.

A cooling shroud surrounds sensitive valve components. The shroud allows cooling air to pass over the components to prevent overheating. A locking crank and pin is mounted on the actuator. The locking pin when installed in the locking crank manually locks the valve 48 +/- 4° from the valve closed position and vents supply pressure.

Valve Operation

The fan air modulating valve opens and closes in response to pressure signals from the fan air temperature sensor.

The actuator modulates the disk to maintain a bleed outlet air temperature at 400° +/- 30° F (204° C). The valve begins to open at 370° F (188° C) and fully opens at 430° F (221° C).

BITE Switches and Sensor

Two BITE pressure switches, a BITE temperature sensor and valve limit switches are used to monitor the system's integrity. The air supply BITE module uses the following logic to identify faults in the fan air system:

• When bleed air temperature is below 265° F (129° C), the sensed servo pressure (switch 1) . should be greater then 9.25 psig and the fan air valve should be closed.

• When bleed air temperature is above 445° F (229° C), the servo pressure (switch 2) should be open and the fan air valve should be open.

The BITE module first tests the fan air sensor. If no faults are found, then it tests the fan air valve for faults. A fault in the sensor will inhibit a fault indication of the valve. If no faults are found in either the sensor or the valve the BITE module, then tests the precooler by monitoring the precooler out temperature through the fan air sensor.

Page 33: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 33 5/21/13 EFF - ALL

POPPET REGULATED VALVE CLOSED POSITION SWITCH

AIR SUPPLY BITE MODULE

TO BITE MODULE

PRESSUREREGULATING CONTROL

CONTROL NO. 1 POPPET BITEPRESSURE AND

PRESS. NOZZLE SWITCH

PRESS. 9.25 PSI IF THEN

TEMP VALVE TEST PORT

<265` >9.25PSI

POSITIONSWITCHES

AMBIENT OPEN

CLOSEDLOCKINGPIN

OPEN

AMBIENT

VALVECONTROL NO. 2 LEVER BITE

SENSOR PRESS.

DIAPHRAGM SWITCH

COMPENSATING

BALL POPPET REGULATOR

CLOSED

>445` <2.25PSI OPEN

FILTER

FEEDBACKCAM

COOLING AIR

FANAIR

LOCKINGPIN SLOT

CLOSE

LOCKINGPIN HOLE

SPRINGSSIGNAL

VALVE PRESSURECONTROL

LEVER

TEMP PROBE (BIMETALLIC)

BLEED BLEED AIR PR

-AIR

FROM PRECOOLER

PRESS. 2.25 PSI

TEMPERATURE

INCREASING BITETEMP TEMP

SENSOR

INLET TO PRESSURE

REGULATING & SHUTOFF VALVE

PRSOV (REF) OPEN

LOCKINGCRANK

TEMPERATURE REGULATED CONTROL PRESSURE FROM FAN AIR TEMPERATURE SENSOR

POSITIONSWITCHCONNECTIONS

SIGNAL PRESSURE LOCKING FROM PRECOOLER CRANK

FILTERACTUATOR

LOCKINGPIN

DISK

OUTLET PORT TO PRECOOLER

BITE TEMP SENSOR

BLEED AIR TEMP PROBE

UP ACCESSDOOR FRAME

FWD

CONTROL PRESSURE ELECTRICAL CONNECTION

BITEPRESSURESWITCHES

FILTER

__________________________

FAN_AIR_MODULATING_VALVE NOTE: VIEW FROM RIGHT SIDE OFENGINE INTO STRUT ACCESS DOOR

FAN AIR SYSTEM

B767-300 CH 36-00 TRAINING MANUALPAGE - 33 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLYPage 33

PNEUMATIC SUPPLY - FAN AIR SYSTEM

Page 34: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 34 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - AIR SUPPLY PRECOOLER

Purpose

The precooler is the part of the engine bleed air temperature control system that transfers the heat from the bleed air to the fan air without mixing the two together.

Location

The precooler is mounted to the lower engine strut firewall. The precooler is in the area between the engine and engine strut and is accessible by opening the thrust reverser and core cowling. Physical Description/Features

The air supply precooler is an air-to-air heat exchanger of the cross-flow type. The unit consists of layers of fins separated by parting plates and closure bars. The bleed air inlet receives pressure regulated bleed air from the PRV. A pressure sense port on the precooler provides servo pressure to the fan air valve, which is attached to the fan air inlet.

Operation

The precooler allows heat from engine bleed air to be absorbed by cooler fan air. Bleed air and fan air flow at approximately right angles to each other, separated by the fin-plate arrangement. Heat from the bleed air is absorbed by the fan air via the fins and plates, thereby cooling the bleed air to a nominal 400 +/- 30° F (204° C).

Page 35: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 35 5/21/13 EFF - ALL

MOUNTING POINTS

2 OF 4

BLEED AIR OUTLET

TO PRSOV

FAN AIR INLET

BLEED AIR INLETFROM THE PRV

FWD

AIR SUPPLY PRECOOLER

FAN AIR OUTLET

B767-300 CH 36-00 TRAINING MANUALPAGE - 35 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLYPage 35

PNEUMATIC SUPPLY - AIR SUPPLY PRECOOLER

Page 36: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 36 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - PRESSURE REGULATING AND SHUT-OFF VALVE

Purpose

The Pressure Regulating and Shutoff Valve (PRSOV) provides four basic functions:

• ON/OFF control of the engine bleed air system • Pressure regulation of the engine supplied bleed air • Engine bleed air temperature limiting (protection) and prevents reverse

flow from the pneumatic distribution system into the engine bleed air system

Location

The PRSOV is mounted to the six inch (15 cm) ducting downstream of the precooler in the engine strut (pylon).

Physical Description/Features

The multipurpose PRSOV is a pneumatically operated and electrically controlled valve. The valve incorporates a valve body and disk, an actuator, a pressure controller, a reverse flow limiter, a temperature probe, limit switches, pressure switches, a solenoid, and devices for locking the valve closed. The spring loaded closed valve has a valve shaft extension which is splined to the valve disk and a locking crank. The locking crank extends on either side of the valve shaft and one end is used as an actuation arm for the Open/Close limit switches. The other end has a threaded hole which allows the valve to be locked closed when a lock pin is installed. The lock pin is stowed on the valve. The locking crank has a hex for manual operation of the valve.

Electrical control is provided by a latching type solenoid. Pressure switches and position switches are installed to provide information for the Air Supply BITE MODULE and the engine bleed air control circuit. The valve serves as a firewall shutoff valve and constitutes a part of the firewall.

Operation

The solenoid is energized to the AUTO position by a signal from the bleed air control card. The valve is pneumatically actuated to maintain 40 +/- 10 psi. The BITE pressure and position switches provide information to the air supply BITE module.

BITE

The BITE module monitors the valve for faults. It compares the OFF solenoid signal to the closed position switch (valve should be closed); the 60 psi pressure switch to the OFF position switch (valve should be closed); and the 20 psi pressure switch to the OPEN position switch (valve should be open).

Ground Handling

The MEL requires that at least one PRSOV be operational, along with several exceptions, to dispatch the airplane. The dispatch deviations guide (DDG) provides the steps required to satisfy the exceptions. One of these exceptions requires the failed PRSOV to be in the closed position. To insure the valve stays in the closed position, the locking pin may be installed in the locking pin hole in the locking crank when the valve is fully closed. If the valve is not fully closed, use a wrench on the hex, rotating the locking crank until the locking pin hole aligns with a hole in the valve body. When restoring the PRSOV to normal operation, insure the LOCKING PIN is installed in its stowed position securely. If the pin is not installed or not installed completely, the valve will not operate.

Page 37: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 37 5/21/13 EFF - ALL

TEMPERATURE CONTROL 450`F - 490`F

FROM PRECOOLER

NO. 1 NO. 2 BITE BITE PRESS PRESS SWITCH SWITCH

PRESSURE CONTROL 40 +/ - 10 PSI

LOCKING PIN (STOWED) VALVE ACTUATOR REVERSE FLOW (SPRING LOADED CHECK CONTROL

CLOSED) ÄP.18 PSI SOLENOID CONTROL AUTO OFF

OPEN/CLOSE POSITION SWITCHES

FROM STARTER LOCKING_PIN

P < 20 PSI P > 60 PSI AIR SUPPLY

BITE MODULE

AUTO/OFF

FAN AIR TEMPERATURE SENSOR TO AIR SUPPLY DISTRIBUTION

VALVE BODY

TEMPERATURE SENSOR

LOCKING PIN HOLE

CLOSE LOCKING CRANK

HEX LEFT_SIDE_VIEW

LOCKING PIN (STOWED POSITION)

SHUTOFF SOLENOID MAIN FILTER POSITION SWITCHES

ELECTRICAL PRESSURE REGULATING AND SHUTOFF VALVE

TEMPERATURE SENSOR PROBE

DISK HEX FOR CONNECTOR MANUAL OPERATION (VALVE SHAFT BITE PRESSURE EXTENSION) SWITCHES (NOT SHOWN)

VALVE_ROTATED_FOR_CLARITY

PRESSURE REGULATING AND SHUTOFF VALVE

B767-300 CH 36-00 TRAINING MANUAL PAGE - 37 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

INLET PRESSURE

PNEUMATIC SUPPLY - PRESSURE REGULATING AND SHUTOFF VALVE

Page 38: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 38 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - APU SHUTOFF AND CHECK VALVES

Description

The APU shutoff valve is a 4.5 inch diameter, duct mounted, disk valve. It is located in the APU air supply duct just forward of the APU firewall. It opens or closes to allow supply air from the APU to enter the air supply distribution system.

A 115 volt ac motor drives the valve.

The valve consists of an electrical actuator, a body and disk assembly, and a manual override.

The disk assembly opens and closes in response to the electrical actuator or the manual override. The valve can be locked in either open or closed positions.

The disk assembly pivots on a shaft within the body. One end of the shaft engages the output shaft of the actuator. Actuator position determines the position of the disk.

APU Check Valve

The APU check valve is a 6-inch, duct-mounted, dual flapper-type, check valve. It mounts in the APU air supply duct forward of the APU shutoff valve.The valve prevents air flow from the engines or ground air connector from entering the APU.

The check valve consists of two semi-circular flappers hinged about a pin. The pin runs through the center of the valve body normal to the valve body axis.

Normal airflow (away from APU) overcomes the helical torsion spring and drives the check valve flappers open until contact is made with the check valve stop pin. Reverse airflow aids the helical torsion spring to close the check valve.

Page 39: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 39 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - APU SHUTOFF AND CHECK VALVES

Page 40: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 40 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - APU SHUTOFF VALVE CONTROL

Description

Power requirements for the APU shutoff valve include 115v ac power for valve operation, 28v dc for relay control and switchlights, and 5v ac for white bar lights.

Description/Operation

To open the APU AIR SUPPLY valve the following conditions must be met. The APU start switch moved to the START position, which will cause the APU START/ON relay to energize. The APU operating above 95%. The APU FIRE switch in the normal position. The APU AIR SUPPLY switch selected to the ON position and the APU AIR SUPPLY OVERRIDE relay relaxed. This override relay will be relaxed if any of the following sets of conditions is satisfied:

• Starting either engine • Both engines N2 RPM is below 50% • The center isolation valve is closed • Both left and right PRSOVs are closed

Closing of the APU air supply valve can be done by selecting the APU air supply to the OFF position. The valve will close automatically whenever all of the following are met: left or right PRSOV(s) open, the center isolation valve open an engine is not being started and either engine(s) N2 above 50%. The valve will also close automatically when the APU is selected off, or the APU fire switch is in the fire position or the battery switch is placed off. (The battery bus supplies the power for the APU start/on relay).

Valve Indication

The "VALVE" light will illuminate in the APU air supply valve switchlight if a disagreement exists between commanded and actual valve position. If the disagreement lasts longer than six seconds, a level "C" APU BLEED VALVE message will be displayed by the EICAS.

Page 41: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 41 5/21/13 EFF - ALL

START R ENG STARTING

L ENG STARTING

CENTER ISOLATION VALVE CLOSED

BOTH ENGINES N2 < 50%

R PRSOV

1

2

3

4

5

APU START/ON RELAY ENERGIZED

APU N2 > 95%

APU FIRE SW 1 IN NORMAL (FLT COMPT) APU AIR SUPPLY VALVE

APU AIR SUPPLY "OPEN" SWITCH SELECTED

TO ON (P5)

APU AIR SUPPLY

AUX PWR CONTROL UNIT

CLOSED OVERRIDE RELAY NOT ENERGIZED

COMMAND SIGNAL L PRSOV CLOSED

1 APU AIR SUPPLY VALVE COMMAND SIGNAL

DISAGREES WITH ACTUAL VALVE POSITION

V A "C" APU BLEED L V E

VALVE LIGHT (P5) EICAS MESSAGE (6 SECOND DELAY)

APU SHUTOFF VALVE CONTROL

B767-300 CH 36-00 TRAINING MANUAL PAGE - 45 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

PNEUMATIC SUPPLY - APU SHUTOFF VALVE CONTROL

Page 42: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 42 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - ISOLATION AND ISOLATION BYPASS CHECK VALVES

Description/Location Isolation Valve

There are three isolation valves in the air supply system. The left and right isolation valves are located in their corresponding air supply body crossover ducts. The center isolation valve is in the APU air supply duct just aft of the crossover duct, on the forward wall of the left wheel well.

All three isolation valves are non-modulating 6-inch diameter disk valves. The valves are powered by 115 volt ac. A lever normally engaged with the motor drive disengages to allow manual movement of the disk independent of the valve motor.

Isolation Bypass Check Valve

Two isolation bypass check valves are mounted directly under the left and right isolation valves. The check valves are flapper-type valves with a 5-inch diameter inlet and a 4-1/2 inch-diameter outlet. The check valves consist of two semi-circular flappers attached to a hinge pin. The hinge pin runs through the center of the valve body.

Airflow in the direction of the arrow on valve body overcomes a helical torsion spring and drives the valve flappers open until contact is made with the check valve stop pin. Reverse airflow aids the helical torsion spring in closing the valve flappers.

Note: Clamps with safety latches must be installed on the inboard side of the left and right isolation valves and bypass check valves and on the lower side of the center isolation valve.

Page 43: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 43 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - ISOLATION AND ISOLATION BYPASS CHECK VALVES

Page 44: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 44 5/21/13 EFF - ALL

PNEUMATIC SUPPLY - ISOLATION VALVE CONTROL

Operation

Power requirements for the valves include 115 volts ac power for operation, 28 volts dc power for the indication part of the circuit, and 0-5 volts ac power for white flow bar illumination (panel lights).

There is a separate switchlight to control each valve (left, right, and center). The CENTER ISOLATION VALVE control switchlight is normally selected to the OPEN position and is guarded to that position.

The control circuits for the three valves are similar so only the circuit for the left valve is shown.

When the control switchlight is pressed to OPEN (Flow Bar Displayed), 115 volts ac powers the valve open. When the valve control switchlight is pressed again (Flow Bar Not Displayed), 115 volts ac powers the valve closed.

28 volts dc provides power to the indication relays which control the amber disagreement lights and the EICAS indications. The amber VALVE light is on during valve actuation and off when valve reaches its commanded position.

This is determined by the limit switches on each valve. If the amber light remains on for greater than six seconds, a disagreement between the valve position and command is indicated on EICAS as a level C message.

Indication power is provided by the STBY bus. Operating power is provided by the XFR BUS. Its closed indication relay provides a discrete input to the ENG EEC.

The Center ISLN VLV CONTROL SWITCH provides a discrete input to the L ENG EEC. The Center ISLN VLV closed IND relay is part of the control circuit for the APU AIR SUPPLY VALVE.

Operation - Simplified

There is a separate switchlight to control each isolation valve (left, right, and center). The CENTER ISOLATION VALVE switchlight is guarded in the valve open position. When the switchlight is depressed to open, 115 volts ac powers

the valve open. When the valve switchlight is depressed again, 115 volts ac powers the valve closed.

28 volts dc is provided through relay logic for the amber valve disagreement light. The amber VALVE light is on during valve actuation and off when valve reaches its selected position.

This is determined by the limit switches on each valve. If the amber light remains on, a disagreement between the valve position and selected is indicated. If the disagreement last longer than 6 seconds the EICAS advisory message L(C)(R) BLD ISLN VAL Will be displayed.

Page 45: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 45 5/21/13 EFF - ALL

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 45 2/27/13 EFF - ALL

00-63 HC003-767B TRAINING MANUALPAGE - 49 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

LEFT ENGINE AIR

PNEUMATIC SUPPLY - ISOLATION VALVE CONTROL

PNEUMATIC SUPPLY - ISOLATION VALVE CONTROL

Page 46: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 46 5/21/13 EFF - ALL

PRESSURE INDICATION SYSTEM - AIR SUPPLY INDICATION

Purpose

The air supply indication system provides information to the flight crew and maintenance personnel. The system monitors and displays normal and abnormal system conditions.

Description

The system consists of engine bleed air control cards, duct pressure indication, an air supply bite module, overheat and valve operation annunciation.

The duct pressure indicating circuit has transducers in each air conditioning compartment, and display is provided on EICAS and on the air supply control panel. The air supply bite module is located in the main equipment center. The air supply bite module receives information from the left and right bleed air supply system components, air/ground relays, air driven hydraulic pump operation, and both bleed air control cards.

The air supply bite module can be interrogated for system faults when the engines are not operating. The module has memory of up to eight flights.

Page 47: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 47 5/21/13 EFF - ALL

PRESSURE INDICATION SYSTEM - AIR SUPPLY INDICATION

B767-300 CH 36-00 TRAINING MANUAL PAGE - 51 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

490° F

Page 48: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 48 5/21/13 EFF - ALL

PRESSURE INDICATION SYSTEM - AIR SUPPLY DUCT PRES-SURE INDICATION

Description

The right and left air supply duct transmitters are connected to short sensing lines to monitor air pressure on either side of the distribution system. Output signals from these transmitters are routed to the duct pressure indicator and to the two EICAS computers.

Operation

The pressure transmitters are powered by 28 volts dc from the L and R dc buses. In the pressure transmitters, pressure variations cause a bellows to move the wiper arm of a potentiometer.

The resultant voltage from the potentiometer is amplified and then routed to an EICAS computer where it is processed for display on the lower EICAS display unit. The transmitter voltages are also routed to a dual air supply duct pressure indicator which is powered by 115 volts ac from the left 115 volt ac bus. The signal voltages vary from 0.4 to 5.2 volts dc for the pressure range of 0-80 psi.

The signal from each pressure transmitter is processed by a servo amplifier. The servo amplifier powers a torque motor which in turn rotates the left or right indicating needle, as appropriate. Whenever the input voltage changes, the torque motor will rotate the display needle until the servo amplifier's input signal is nulled out by a voltage from the rebalance potentiometer which is equal in amplitude, but opposite in polarity.

Page 49: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 49 5/21/13 EFF - ALL

PRESSURE INDICATION SYSTEM - AIR SUPPLY DUCT PRESSURE INDICATION

28V DC L BUS POWER C1332 SUPPLY LEFT AIR SUPPLY DUCT PRESS

28V DC R BUS B

DC C1342 RIGHT AIR SUPPLY

DUCT PRESS IND 115V AC L BUS POWER C4221 SUPPLY

AIR SUPPLY DUCT PRESS IND PWR P11 OVERHEAD CIRCUIT BREAKER PANEL

TORQUE MOTOR SERVO AMP

L AIR SUPPLY DUCT PRESS TRANSMITTER + -

DC

LEFT EICAS COMPUTER C C R O

60 40

20

80 DUCT PRESS PSI 0

REBALANCE S POTENTIOMETER POWER S

SUPPLY T DC A L A K

B + - U

ECS/MSG L R DUCT PRESS 45 35

EICAS LOWER DISPLAY UNIT (P2) TORQUE MOTOR

SERVO S AMP

DC R AIR SUPPLY DUCT PRESS TRANSMITTER RIGHT

EICAS REBALANCE COMPUTER POTENTIOMETER

DUAL AIR SUPPLY DUCT PRESSURE INDICATOR(P5)

TO TAT TO LEFT PROBE HEAT TO FWD TO RIGHT COOLING & RAIN CARGO COOLING

PACK REPELLENT HEAT PACK

B A V44 L V45 R AIR SUPPLY AIR SUPPLY ISLN VLV ISLN VLV

L ENG R ENG BLEED AIR BLEED AIR

PNEUMATIC GROUND CONNECTIONS V46 C

AIR SUPPLY ISLN VLV

APU BLEED AIR AIR SUPPLY DUCT PRESSURE INDICATION

B767-300 CH 36-00 TRAINING MANUAL PAGE - 53 27 Jul 2012 EFF- ALL FOR TRAINING PURPOSES ONLY

Page 50: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 50 5/21/13 EFF - ALL

PRESSURE INDICATION SYSTEM - DUCT PRESSURE TRANSMITTERS

Purpose

The pressure transmitters provide a variable signal to the dual duct pressure gage, (P5) and to the EICAS computers for duct pressure indication.

Location

The transmitters are mounted to support brackets near access doors forward of the Air Conditioning compartments.

Description

The transmitters consist of a housing with an electrical connector on one end and an pneumatic connector on the other. There is an amplifier, a potentiometer, and a bellows assembly contained in the housing.

Page 51: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 51 5/21/13 EFF - ALL

PRESSURE INDICATION SYSTEM - DUCT PRESSURE TRANSMITTERS

SEE D

FROM LEFT ENGINE

LEFT DUCT

FROM LEFT DUCT PRESSURE ENGINE TRANSDUCERS

DUCT PRESSURE TRANSDUCERS

FROM RIGHT

PRESSURE TRANSDUCER

PNEUMATIC DUCT (REF)

FWD

FROM APU

ENGINE RIGHT DUCT PRESSURE TRANSDUCER

D 1

FWD

FROM APU

D 2 1

1 2

141 - 999 101 - 139

141 - 999

DUCT PRESSURE TRANSMITTERS

B767-300 CH 36-00 PAGE - 57 27 Jul 2012 EFF- ALL

TRAINING MANUAL FOR TRAINING PURPOSES ONLY

FROM APU

Page 52: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 52 5/21/13 EFF - ALL

AIR SUPPLY BITE SYSTEM - OPERATIONAL CHECKS

Description

The air supply bite module uses 115 volt ac power from the left bus. When both engines are operating, operational logic is provided to the bite module for left and right system monitoring.

Operation High Pressure Shutoff Valve

The module will fault the shutoff valve for the following:

• High stage pressure greater than 127 psi (pressure switch No.1, PHH open) and the valve disk is open (position switch).

• High stage pressure is less than 62 psi (pressure switch No. 2, PHL closed) and the valve disk is closed (position switch).

• High pressure controller solenoid with OFF signal and the valve disk is open (position switch).

High Pressure Controller

The module will fault the controller for the following:

• High stage pressure greater than 127 psi (pressure switch No. 1, PHH) and control pressure is greater than 14 psi (PC servo pressure switch).

• High stage pressure less than 62 psi (HP pressure switch No. 2, PHL) and control output pressure not within supply pressure by 20 psi (differential pressure switch, PH-PC).

• Controller solenoid OFF signal applied and servo pressure is greater than 14 psi (PC servo pressure switch).

Pressure Regulating Valve and Controller

The module will fault the valve/controller for the following:

• Overpressure switch closed and the valve disk open (position switch). • Controller solenoid OFF signal applied and the valve open (position

switch).

Pressure Regulating and Shutoff Valve

• The module will fault the pressure regulating and shutoff valve for the following:

• Solenoid OFF signal applied and the valve disk open (position switch). • Downstream pressure is greater than 60 psi (PR pressure switch No. 1)

and the valve disk is open (position switch). • Downstream pressure less than 20 psi (PR pressure switch No. 2) and

valve disk is closed (closed position switch). Inhibits test if temperature is greater than 420° F (216° C), (fan air bite temperature sensor) or if the high pressure shutoff valve is closed and high stage pressure is less than 62 psi.

• Temperature greater than 550° F (287° C) (fan air bite temperature sensor).

Fan Air Modulating Valve

The module will fault the valve for the following:

• Temperature is greater than 430° F (221° C), as sensed by the fan air bite temperature sensor, and the valve is not open as sensed by the position switch. The valve fault is inhibited if the fan air temperature sensor is faulty.

• Temperature less than 265° F (129° C) as sensed by the fan air bite temperature sensor, and the valve is not closed, as sensed by the position switch. The valve fault is inhibited if the fan air temperature sensor is faulty.

Fan Air Temperature Sensor

The module will fault the sensor for the following:

• Temperature less than 265° F (129° C) as sensed by the fan air bite temperature sensor and pressure is less than 9.25 psi as sensed by pressure switch No. 1.

• Temperature greater than 445° F (229° C), as sensed by the fan air bite temperature sensor, and pressure is greater than 2.25 psi, as sensed by fan air control pressure switch No. 2.

Air Supply Bite ModuleThe bite module conducts a self-test using temperature sensors and position switches to test for out-of-range checks, ground position check, and open wire tests.

Page 53: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 53 5/21/13 EFF - ALL

AIR SUPPLY BITE SYSTEM - OPERATIONAL CHECKS

Page 54: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 54 5/21/13 EFF - ALL

AIR SUPPLY BITE SYSTEM - GROUND CHECKS

Description/Operation

The air supply BITE system identifies and stores LRU faults that occur within the engine air supply system. The BITE module continuously checks the system operation and identifies components faults. The processor stores this information in a nonvolatile memory for up to eight flights. When power is applied to the module, the main routine activates a self-test.

The first one is a comprehensive test, it takes less than two seconds. If the comprehensive test fails, the main routine automatically turns on the BITE module lamp and stores the fault. All other module functions are inhibited when this lamp is on. If the lamp stays on you must replace the Air Supply BITE module. If the lamp goes off, or never came on, the main routine continues. The main routine then starts periodic testing. This is a shorter test. The module will return to the comprehensive test if power is interrupted or if a fault is found. If everything is OK, the main routine will select a mode. It can select from two modes.

Operational Check Mode

If the airplane is in the air, or there is at least one engine running, the main routine selects the operational check mode. In the operational check mode the module continuously checks to make sure all components in the engine bleed and BITE systems are operating correctly. Any detected faults are stored in memory. The switches and the LED lamps on the front panel of the module are inactive in the operational check mode.

Ground Check Mode

When the airplane is on the ground with both engines shutdown, the main routine selects the ground check mode. In this mode the module continuously monitors the wiring and BITE components. If they are not in their engine off position, a fault is stored in memory.The front panel switches and lamps are enabled. If faults are detected, BITE stores the faults in its memory, no lamps turn on.

Built-In Test

The air supply BITE module incorporates circuitry to isolate functional failures of components due to critical wire and connector failures, as distinguished from component failure, and records intermittent flight failures that may not repeat on the ground. Identification of failed items is stored in the air supply BITE module. Actuation of the PRESS TO TEST switch on the BITE panel will test power to the unit and the function of the panel lights and displays.

Actuation of the BITE switch will cause the light of the failed item to be illuminated. Fault indicators are stored in previous fault memory for eight flights, after which they are automatically cleared.

Verification Test

After replacement of failed LRU, actuation of the VERIFY switch will confirm that the replacement LRU is installed correctly, its basic function is operable and its interfaces have been re-established.

If the NO FAULT light illuminates during verification, verification is OK and allows reset of the BITE data store. Failure to pass the verification test is indicated by illumination of the failed LRU light.

Reset

During reset, all "BITE STEP" faults are cleared from nonvolatile memory.

The "VERIFY" switch must be pressed and the "NO FAULT" light illuminated before the "RESET" switch is pressed.

Page 55: B767 ATA 36 Student Book

TRAINING MANUALFOR TRAINING PURPOSES ONLY

B767-3S2F ATA 36-00 Page - 55 5/21/13 EFF - ALL

AIR SUPPLY BITE SYSTEM - GROUND CHECKS