B PEAD-RP100JALQ PEAD-RP100JALQC PUHZ-SHW112VHA(-BS) PUHZ-SHW112YHA(-BS)E Inside dB 63 63
F Out-side dB 69 69
G R410A GWP 1975 *14.9 4.9
J B BK kWh/a 714 714L kW 10 10
3.8 3.8J A AK kWh/a 4664 4664L kW 12.7 12.7
P kW 11.2 (-10℃) 11.2 (-10℃)
R kW 11.2 (-7℃) 11.2 (-7℃)
S kW 9.4 (-25℃) 9.4 (-25℃)
T kW 1.5 1.5
at operation limittemperature
Back up heating capacity
M
Heating(Aver-ageseason)
SCOPEnergy efficiency classAnnual electricity consumption *2Design load
NDe-claredcapacity
at reference de-sign temperatureat bivalent tem-perature
DSound power levels on coolingmode
Refrigerant
H Cooling
SEEREnergy efficiency classAnnual electricity consumption *2Design load
A ModelIndoor unitOutdoor Unit
Function (indicate if present)
If function includes heating: Indicate the heating season theinformation relates to. Indicated values should relate to oneheating season at a time. Include at least the heating seasonAverage (mandatory) Y
PRODUCT INFORMATION (*)
PACKAGED AIR CONDITIONERINDOOR MODEL PEAD-RP100JALQOUTDOOR MODEL PUHZ-SHW112VHA(-BS)
cooling Y Warmer (if designated) N
Item symbol value unitDesign load
heating Y
SEER 4.9
Colder (if designated)
Item
N
symbol value unit
SCOP/A 3.8 -
Seasonal efficiencycooling Pdesignc 10.0 kW cooling -
heating/Warmerheating/Average Pdesignh 12.7 kW heating/Averageheating/Warmer Pdesignh x kW SCOP/W x -heating/Colder Pdesignh x kW heating/Colder SCOP/C x -
Declared capacity for cooling, at indoor temperature 27(19)℃and outdoor temperature Tj
Declared energy efficiency ratio, at indoor temperature 27(19)℃ and outdoor temperature Tj
Tj=35℃ Pdc 10.0 kW Tj=35℃ EERd 3.4 -Tj=30℃ Pdc 7.3 kW Tj=30℃ EERd 4.7 -
Tj=25℃ EERd 6.3 -Tj=25℃ Pdc 5.4 kWTj=20℃ EERd 7.9 -Tj=20℃ Pdc 5.6 kW
Declared capacity for heating/Average season, at indoortemperature 20℃ and outdoor temperature Tj
Declared coefficient of performance/Average season, atindoor temperature 20℃ and outdoor temperature Tj
Tj=-7℃ Pdh 11.2 kW Tj=-7℃ COPd 2.7 -3.7 -Tj=2℃ Pdh 6.8 kW
Tj=7℃ Pdh 4.4 kWTj=2℃ COPd
Tj=12℃ COPd 5.7 -Tj=7℃ COPd 4.9 -
Tj=bivalent temperature Pdh 11.2 kWTj=12℃ Pdh 5.1 kW
1.5 -Tj=bivalent temperature COPd 2.7 -
COPd x -
Declared capacity for heating/Warmer season, at indoortemperature 20℃and outdoor temperature Tj
Tj=operating limit Pdh 9.4 kW Tj=operating limit COPd
Tj=7℃ Pdh x kW
Declared coefficient of performance/Warmer season, at indoortemperature 20℃ and outdoor temperature Tj
Tj=2℃ Pdh x kW Tj=2℃Tj=7℃ COPd x -Tj=7℃ Pdh x kWTj=12℃ COPd x -Tj=7℃ COPd x -
Tj=bivalent temperature Pdh x kWTj=12℃ Pdh x kW
x -Tj=bivalent temperature COPd x -
Tj=operating limit Pdh x kW Tj=operating limit COPd
Declared capacity for heating/Colder season, at indoortemperature 20℃and outdoor temperature Tj
Declared coefficient of performance/Colder season, at indoortemperature 20℃ and outdoor temperature Tj
Tj=-7℃ Pdh x kW Tj=-7℃ COPd x -Tj=2℃ COPd x -Tj=2℃ Pdh x kWTj=7℃ COPd x -Tj=7℃ Pdh x kWTj=12℃ COPd x -Tj=12℃ Pdh x kWTj=bivalent temperature COPd x -Tj=bivalent temperature Pdh x kWTj=operating limit COPd x -Tj=operating limit Pdh x kWTj=-15℃ COPd x -Tj=-15℃ Pdh x kW
Bivalent temperature Operating limit temperatureheating/Average Tbiv -7 ℃ heating/Average Tol -25 ℃
heating/Warmer Tol x ℃heating/Warmer Tbiv x ℃heating/Colder Tol x ℃heating/Colder Tbiv x ℃
Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc x kW for cooling EERcyc x -
for heating COPcyc x -for heating Pcych x kWDegradion co-efficient heating Cdh 0.25 -Degradation co-efficient cooling Cdc 0.25 -
Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode POFF 15 W cooling QCE 714 kWh/a
heating/Average QHE 4664 kWh/astandby mode PSB 15 Wx kWh/athermostat - off mode PTO(c/h) 212/74 W
crankcase heater mode PCK 0 Wheating/Warmer QHE
63/69 dB(A)
heating/Colder QHE x kWh/a
staged N Global warming potential GWP
Capacity control (indicate one of three options) Other items
fixed N Sound power level(indoor/outdoor)
LWA
variable Y Rated air flow(indoor/outdoor)
- 2520/6000 m3/h
1975 kgCO2eq.
Contact details for obtaining MITSUBISHI ELECTRIC CORPORATION SHIZUOKA WORKS3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, Japan
(*) This information is based on the "product information requirement" in COMMISSION REGULATION (EU) No206/2012.
Contact details for obtainingmore information
3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, JapanE-mail: [email protected]
Function
Capacity control
ItemSeasonal efficiency (2)
Energy efficiency class
Other items
250H1400W732D (mm)OUTDOOR MODEL PUHZ-SHW112VHA(-BS) 1350H950W330D (mm)
cooling Yheating Y
TECHNICAL DOCUMENTATION (1)
PACKAGED AIR CONDITIONERINDOOR MODEL PEAD-RP100JALQ
Colder (if designated) N
fixed N
The heating seasonAverage (mandatory) Y
Warmer (if designated) N
symbol value unit
staged Nvariable Y
heating/Average SCOP/A 3.8 -cooling SEER 4.9 -
-
heating/Colder SCOP/C x -heating/Warmer SCOP/W x -
heating/Average SCOP/A A -cooling SEER B
dB(A)
heating/Colder SCOP/C x -heating/Warmer SCOP/W x -
Refrigerant - R410A -Sound power level (indoor/outdoor) LWA 63/69
Global warming potential GWP 1975 kgCO2eq.
(1) This information is based on COMMISSION DELEGATED REGULATION (EU)No626/2011.(2) SEER/SCOP values are measured based on FprEN 14825:2011: Testing and rating at part load conditions and calculation of seasonal performance.
identification and signatureof the person empowered tobind the supplier
Hideyo TamuraManager,Packaged Air Conditioners Quality Control SectionMITSUBISHI ELECTRIC CORPORATION SHIZUOKA WORKS