7
AVK Part of the AVK PENTOFLOW MAINS TO METER range

AVK - proflo.ie

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AVK - proflo.ie

AVKPart of the AVK PENTOFLOW MAINS TO METER range

Page 2: AVK - proflo.ie

The new AVK range of Water Meter Boundary Boxes, comprises of a class leading, composite Grade B surface box able to withstand an 8 tonne loading and allowing, if required, Automated Meter Reading Technology (AMR).

With patented push-fit connections in d20, 25and 32mm, ½" HG and also ¾" BSP Female threaded.

• The unique surface box element has a 8 tonne rating, suitable for footpaths and driveways with regular traffic.

• Available as a fully sealed Class 1 or unsealed Class 2.

• Telescopic with a height adjustment from 555-850mm.

• The base unit manifold is a one piece design with a minimum number of components, reducing potential leak paths.

• Patented push-fit connections - no need to twist and also demountable by unscrewing nut.

Technical Specification – MaterialsWRAS approved materials are used throughout and full datasheets are available through the AVK UK website. www.avkuk.co.uk

• Main body, base plate, sliding guard tube, retainer ring, cover frame and cover assembly: Polypropylene (PP), higher mechanical resistance and thermal stability.

• Manifold retainer nut, manifold assembly push-fit and blanking plug 27mm AF hex: Acetal

• O-ring and seal for telescopic movement: NBR 70

• Frost protection: Plasazote LDPE

Standards• WIS 4-37-01 for boundary boxes• Surface box to BS 5834-2:2011• Push-fit joints according to WIS 4-32-11

Working temperature-15° C to + 35° C

Nominal Pressure (PN) and Product ApprovalsThe AVK is designed and pressure rated to PN16.

TeChNiCAl iNTroduCTioN

AVK UK Water Mains to Meter Offer & Price List 2016 | 2

Page 3: AVK - proflo.ie

The AVK range is manufactured by AVK Plastics in the Netherlands. The standard d25mm sealed version is available ex-stock at our National Distribution Centre in Corby, Northamptonshire.

The AVK has been designed to offer the installer advantages during installation and also the local utility once it is in operation, with or without a water meter. The AVK push-fit joints allow an easy connection but also if required can be de-constructed with ease.

The O-ring seal will ensure a reliable connection when the pipe is inserted. Height adjustment can be easily achieved for re-instating by adjusting the telescopic sliding guard. The surface box also has a 7° degree angle of adjustment and once installed the Grade B composite surface box can withstand a class leading 8 tonne load.

Surface box • Surface Box is Grade B – 8 tonne rated as

standard. Grade C – 3 tonne rating can be offered.

• Grade B means that it can be installed in a driveway and footpath with regular traffic.

• Composite materials do not hinder the radio signal if AMR is being used.

• 70 angle of adjustment if on slope.

Class 1 sealed• Completely water tight.• Less susceptible to frost damage.• Easier to read the meter.• Minimises chance of any contamination.

Telescopic• Best option for new installations and also

stop tap replacements.• Height adjustment from 555-850mm.• Shape of guard pipe makes it easy to

install a meter.• Design also reduces any direct stress on

the manifold.

Manifold• One piece manifold incorporating a ¼ turn

ball valve• Minimum number of joints and seals

reducing potential leak paths.

Joint options• d20-32mm Patented push-fit connections.• ½" HG push-fit, ½" HG compression and

¾" BSP female threaded.• No special tool needed to demount nut.• Liners included where required.

FeATureS ANd BeNeFiTS

3 | AVK UK Water Mains to Meter Offer & Price List 2016

Page 4: AVK - proflo.ie

© AVK GROUP A/S 2012-2016 - AVK UK Ltd. - Tel.: +44 (0) 1246 479100 - [email protected] - www.avkuk.co.uk version AA

Installation manualWater meter boundary box

No need to twist

No need to twist

No need to twist

No need to twist

1. Mark the pipe 54mm from the end.2. Prepare hole with level base.3. Remove stickers from push fit connections and take plastic sleeves out of push fit.4. Place sleeves into pipes and insert pipes into push fit connections (no need to twist). Push pipe as far as marked in step 1.

9. Use a straight edge to make sure the top of the boundary box is perfectly aligned with the ground level.10. Continue filling the hole with ±100mm layers of gravel and compact thoroughly at each step.

5. Remove cover and insulation pad. To remove the insulation pad, push one side down to be able to take it out. Store cover and pad in a clean area.6. Adjust height of telescopic boundary box.

11. For high load bearing requirements it is necessary to lay sufficient support, from 30mm under the cover frame up to the top of the cover frame.

7. Fill hole with gravel in steps of ±100mm layers and compact each layer.8. When the gravel is ±50mm over the outer sleeve, the top of the boundary box needs to be adjusted with the ground level.

12. Clean the seal area in the cover frame so it is clear of debris.13. Reinsert the insulation pad and place the cover onto the boundary box.

2

1

3

4

4

4

4

5

6

8

88

7

9

11

12

13

13

12

10

5

iNSTAllATioN iNForMATioN

AVK

-

-

AVK UK Water Mains to Meter Offer & Price List 2016 | 4

Page 5: AVK - proflo.ie

Type AVK ref. nos. d PN delivery Gross mm / inch bar Code Price £

8054-120-2211-10301000 20 Push-fit 16 B £81.768054-125-2211-10301000 25 Push-fit 16 A £87.418054-132-2211-10301000 32 Push-fit 16 B £94.638054-121-2211-10301000 ½” HG Push-fit 16 B £96.878054-221-2211-10301000 ½” HG Comp 16 C £96.878054-326-2211-10301000 ¾” BSP female 16 B £98.87

8054-120-3211-10301000 20 Push-fit 16 B £74.458054-125-3211-10301000 25 Push-fit 16 B £78.408054-132-3211-10301000 32 Push-fit 16 B £90.108054-121-3211-10301000 ½” HG Push-fit 16 C £94.258054-221-3211-10301000 ½” HG Comp 16 C £94.258054-326-3211-110301000 ¾” BSP female 16 C £96.79

8054-120-2202-10301000 20 Push-fit 16 C £80.458054125-2202-0301000 25 Push-fit 16 B £86.258054132-2202-10301000 32 Push-fit 16 B £92.708054-121-2202-10301000 ½” HG Push-fit 16 C £94.468054-221-2202-10301000 ½” HG Comp 16 C £94.468054326-2202-10301000 ¾” BSP female 16 C £96.48

8054-120-3202-10301000 20 Push-fit 16 C £73.218054-125-3202-10301000 25 Push-fit 16 B £77.888054-132-3202-10301000 32 Push-fit 16 B £89.468054-121-3202-10301000 ½” HG Push-fit 16 C £92.298054-221-3202-10301000 ½” HG Comp 16 C £92.298054-326-3202-10301000 ¾” BSP female 16 C £93.25

605970060 £6.00

605970120 £6.00

605970120 £6.00

605970901 £9.00

942700050 £9.00

605970921 £30.00

TBC £60.00

Series 8054/2211Water Meter Boundary Box Grade B Version, SealedAcetal manifoldPolypropylene frame, sliding tube, retainer ringNBR SealsWIS 4-37-01WRAS approvedPN16

liner included where required

Series 8054/3211Water Meter Boundary Box Grade C Version, SealedAcetal manifoldPolypropylene frame, sliding tube, retainer ringNBR SealsWIS 4-37-01WRAS approvedPN16

liner included where required

Series 8054/2202Water Meter Boundary Box Grade B Version, unsealedAcetal manifoldPolypropylene frame, sliding tube, retainer ringNBR SealsWIS 4-37-01WRAS approvedPN16

liner included where required

Series 8054/3202Water Meter Boundary Box Grade C Version, unsealedAcetal manifoldPolypropylene frame, sliding tube, retainer ringNBR SealsWIS 4-37-01WRAS approvedPN16

liner included where required

Pen

tobox

Blanking Plug Full-flow

long Valve handle

Short Valve handle

Check Valve Assembly

Frost Plug

lid Grade B

Sliding Guard Tube, Cover Frame & lid Grade B

ACCeSSorieS

5 | AVK UK Water Mains to Meter Offer & Price List 2016

Page 6: AVK - proflo.ie

AVK UK Water Mains to Meter Offer & Price List 2016 | 6

Page 7: AVK - proflo.ie

Webshophttps://shop.avkuk.co.uk/

Mains to Meter AUG 2016 Copyright©AVK Group A/S 2016

AVK UK Ltd Northampton Office8 Rushmills Northampton NN4 7YB England

T: +44 (0) 1604 601188 F: +44 (0) 1604 604818E: [email protected]

James Pick Business Manager - Water Mains to MeterM: +44 (0) 7568 429327E: [email protected]