AVEVA P&ID 12.1

User Guide

Page 2: aveva p&id

AVEVA Solutions Ltd

Disclaimer1.1 AVEVA does not warrant that the use of the AVEVA software will be uninterrupted, error-free or free from viruses.

1.2 AVEVA shall not be liable for: loss of profits; loss of business; depletion of goodwill and/or similar losses; loss of anticipated savings; loss of goods; loss of contract; loss of use; loss or corruption of data or information; any special, indirect, consequential or pure economic loss, costs, damages, charges or expenses which may be suffered by the user, including any loss suffered by the user resulting from the inaccuracy or invalidity of any data created by the AVEVA software, irrespective of whether such losses are suffered directly or indirectly, or arise in contract, tort (including negligence) or otherwise.

1.3 AVEVA's total liability in contract, tort (including negligence), or otherwise, arising in connection with the performance of the AVEVA software shall be limited to 100% of the licence fees paid in the year in which the user's claim is brought.

1.4 Clauses 1.1 to 1.3 shall apply to the fullest extent permissible at law.

1.5 In the event of any conflict between the above clauses and the analogous clauses in the software licence under which the AVEVA software was purchased, the clauses in the software licence shall take precedence.

CopyrightCopyright and all other intellectual property rights in this manual and the associated software, and every part of it (including source code, object code, any data contained in it, the manual and any other documentation supplied with it) belongs to, or is validly licensed by, AVEVA Solutions Limited or its subsidiaries.

All rights are reserved to AVEVA Solutions Limited and its subsidiaries. The information contained in this document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted without the prior written permission of AVEVA Solutions Limited. Where such permission is granted, it expressly requires that this copyright notice, and the above disclaimer, is prominently displayed at the beginning of every copy that is made.

The manual and associated documentation may not be adapted, reproduced, or copied, in any material or electronic form, without the prior written permission of AVEVA Solutions Limited. The user may not reverse engineer, decompile, copy, or adapt the software. Neither the whole, nor part of the software described in this publication may be incorporated into any third-party software, product, machine, or system without the prior written permission of AVEVA Solutions Limited, save as permitted by law. Any such unauthorised action is strictly prohibited, and may give rise to civil liabilities and criminal prosecution.

The AVEVA software described in this guide is to be installed and operated strictly in accordance with the terms and conditions of the respective software licences, and in accordance with the relevant User Documentation. Unauthorised or unlicensed use of the software is strictly prohibited.

July 2008 © AVEVA Solutions Ltd, and its subsidiaries 2010 AVEVA shall not be liable for any breach or infringement of a third party's intellectual property rights where such breach results from a user's modification of the AVEVA software or associated documentation.

The AVEVA P&ID Reports user interface is based on the Microsoft® Office Fluent™ user interface.

AVEVA Solutions Limited, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom.

TrademarkAVEVA and Tribon are registered trademarks of AVEVA Solutions Limited or its subsidiaries. Unauthorised use of the AVEVA or Tribon trademarks is strictly forbidden.

AVEVA product/software names are trademarks or registered trademarks of AVEVA Solutions Limited or its subsidiaries, registered in the UK, Europe and other countries (worldwide).

The copyright, trademark rights, or other intellectual property rights in any other product or software, its name or logo belongs to its respective owner.

Page 3: aveva p&id

AVEVA P&ID 12.1 User Guide

Contents Page

AVEVA P&ID 12.1 User Guide

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1About this User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1Overview of AVEVA P&ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1Interfaces with other Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:2

Features of AVEVA P&ID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:2

Project Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:1Upgrading Pipes and Symbols from old Projects. . . . . . . . . . . . . . . . . . . . . . . . 2:1Upgrading the Symbol Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:1Upgrading Symbols and Pipes on Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:2

Project Options Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:5AVEVA P&ID Project Administration Program . . . . . . . . . . . . . . . . . . . . . . . . . . 2:6Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:6Project Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:13VPE Workbench Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:16Project Database Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:25P&ID Reports Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:27Drawing Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:30Item Types Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:41Label Types Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:45Text Styles Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:49Symbols Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:50List of Values Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:62Pipes Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:67Signal Styles Configuration Category. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:87Tracing Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:89

12.1i© 2011 AVEVA Solutions Ltd

Page 4: aveva p&id

AVEVA P&ID 12.1 User Guide

Instruments Configuration Category. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:91Equipment Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:109Valves Configuration Category. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:124Line Fittings Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:138Nozzles Configuration Category. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:141Offsheet Connector Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:142Miscellaneous Configuration Category. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:144Excel Interface Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:154Spec Driven Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:156User Defined Attributes Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:167User Access Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:175PDMS Integration Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:176AI Integration Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:177AVEVA NET Configuration Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:178AE Integration Configuration Category. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:183

Changing Units on a Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:184Associated Project Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:184

Defining Project Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:184Creating a New Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:184Upgrading Symbols from Old Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:185Avoiding Problems when using Client Symbology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:185Symbol Utility Programs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:185

Defining a New Pipe Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:189Defining a New Signal Line Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:189Defining a New Tracing Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:195Customisation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:195Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:195Start-up Routines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:195Explorers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:198Right Click Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:198Toolbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:199Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:199Adding Custom Lisp Routines to AVEVA P&ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:199Adding new multi line styles in AVEVA P&ID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:200Running AVEVA P&ID in "Save To Model Mode" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:201Auto Save Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:203Project Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:204Complex Linetypes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:204

12.1ii© 2011 AVEVA Solutions Ltd

Page 5: aveva p&id

AVEVA P&ID 12.1 User Guide

Customising the AVEVA P&ID Tool Palette. . . . . . . . . . . . . . . . . . . . . . . . . . . 2:204Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:204Grouping Palettes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:205Creating New Groups and Palettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:209Adding Signal and Process Lines to the Tool Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:210Adding Symbols to the Tool Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:214

Principles and Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:1Good Drawing Practice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:1Templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:2Automatic Drawing Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:2Pipes and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:2Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:2Pipe Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:3Inserting Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:4

Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:4

The Graphical User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:1Explorer Display Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:1Engineering Explorer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:3Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:3Equipment, Instrument and Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:4Unassigned Items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:6Context Sensitive Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:6Searching for Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:8

Symbol Explorer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:9Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:9Using the Symbol Explorer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:10

Symbol Editor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:14Logging On. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:14Accessing the Symbol Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:14New Symbol Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:15Using the Symbol Editor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:16Closing the Symbol Editor and Updating the Drawing Symbol Library . . . . . . . . . . . . . . . 4:19

P&ID Data Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:21Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:21Viewing P&ID Drawing Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:23Assigning Unassigned Items to a Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:23

12.1iii© 2011 AVEVA Solutions Ltd

Page 6: aveva p&id

AVEVA P&ID 12.1 User Guide

Assigning Sources/Destinations to Page Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:24Viewing and Assigning AVEVA Instrumentation and AVEVA Electrical Data . . . . . . . . . . 4:24Viewing and Exporting to a PDMS Schematic Database. . . . . . . . . . . . . . . . . . . . . . . . . . 4:26Zooming into an item on the Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:28Labelling the Drawing with Data from the P&ID Data Grid. . . . . . . . . . . . . . . . . . . . . . . . . 4:28Configuring the Grid Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:28Exporting the Grid to an Excel Spreadsheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:34Viewing Item Datasheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:34

AVEVA P&ID Tool Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:36The Drawing Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:37Viewing Pipe and Inline Item Properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:37Drawing Page Menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:37

Properties Dialogs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:42Modal Properties Dialogs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:42Non-Modal Properties Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:46

AVEVA P&ID Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:48Home Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:48Data Management Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:58Utilities Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4:61

Upgrading AutoCAD Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:1AutoCAD Drafting Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:1Upgrading AutoCAD Lines to AVEVA P&ID Pipes, Process Links and Signal Lines. . . . . . 5:1Upgrading AutoCAD Blocks to AVEVA P&ID Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:2Upgrading AutoCAD Text to AVEVA P&ID Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:2Viewing Upgraded and Un-upgraded Entities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:2

AutoCAD Drafting Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:3AVEVA P&ID Drawing Upgrade Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:4Starting the AVEVA P&ID Drawing Upgrade Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:4Assigning P&ID Item Types and Symbol Data to AutoCAD Blocks . . . . . . . . . . . . . . . . . . . 5:6Assigning P&ID Symbol Names to AutoCAD Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:8Assigning P&ID Pipe Types to AutoCAD Line Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:11Assigning P&ID Signal Line Types to AutoCAD Line Types . . . . . . . . . . . . . . . . . . . . . . . 5:11

Upgrade Procedures in AVEVA P&ID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:13Upgrading Lines to Pipes and Signal Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:13Upgrading Blocks to Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:18Upgrading Text to Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:21Viewing Upgraded Entities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:25

12.1iv© 2011 AVEVA Solutions Ltd

Page 7: aveva p&id

AVEVA P&ID 12.1 User Guide

Drawing P&IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:1Quick Guide to Drawing P&IDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:1Creating a New Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:4Starting and Exiting AVEVA P&ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:5Titling a Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:5Inserting Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:6Inserting Unassigned P&ID Database Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:7Inserting Unassigned VPE Workbench Items . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:7Drawing Pipes and Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:9Drawing Pipes and Process Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:9Drawing Signal Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:10Tracing Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:11Indicating Pipe Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:11

Selecting Multiple Drawing Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:11Labelling Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:12General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:12Setting Text Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:13Labelling/Editing Non-AVEVA P&ID Text. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:13Label Inheritance from Owning Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:13Labelling Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:14Labelling General Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:15Labelling Inline Fittings (Special Piping Items). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:16Labelling Pipe Destination Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:16Labelling Port Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:17Labelling Instrument Valves (Control Valves) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:17Labelling General Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:18Labelling General Instruments - Using Instrument Pattern Labels. . . . . . . . . . . . . . . . . . . 6:20Labelling General Instruments - Panel Reference Labels . . . . . . . . . . . . . . . . . . . . . . . . . 6:21Labelling System I/O Connections, Interlocks and Logic Boxes . . . . . . . . . . . . . . . . . . . . 6:21Labelling I/O Rockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:21Labelling Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:21Labelling Miscellaneous Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:22Labelling Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:22Labelling Clouds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:22Labelling Pipe Flags. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:22Labelling Revision Triangles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:23Setting Properties Sheet fields to inherit previously entered values . . . . . . . . . . . . . . . . . 6:23

12.1v© 2011 AVEVA Solutions Ltd

Page 8: aveva p&id

AVEVA P&ID 12.1 User Guide

Setting Labels to Inherit Values from Drawing Sheet Attributes. . . . . . . . . . . . . . . . . . . . . 6:23Inserting Symbols with Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:25Automatic Tagging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:25

Labelling Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:26General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:26Label Display Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:28Labelling Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:30Labelling Pipes with Reducers and Reducing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:31Labelling Pipes with Breaks and Inline Breaks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:31Adding Pipe Destination Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:32Modifying Pipe Label Fields and Cascading Changes Through a Pipe Run . . . . . . . . . . . 6:32Setting Properties Sheet fields to inherit previously entered values . . . . . . . . . . . . . . . . . 6:33Setting Labels to Inherit Values from Drawing Sheet Attributes. . . . . . . . . . . . . . . . . . . . . 6:33Inserting Symbols with Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:34Automatic Tagging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:34

Adding User-Defined Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:36Label Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:37Label Validation against Lists of Valid Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:37Label Format Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:38Label Uniqueness Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:39Label Validation across all Project P&IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:39Label Validation against Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:41

Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:42Typical Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:42Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:43Sheet-to-Sheet Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:44Unique identifiers in VPE Workbench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:44Typical Item Flag in AVEVA P&ID Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:44Typical Items in VPE Workbench. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:44Associated Project Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:44

Dynamic Labelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:44Item Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:44Design Data Templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:45Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:45

General Editing, Notes and Revision Clouds . . . . . . . . . . . . . . . . . . . . . . . . . . 6:45Deleting Items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:46Detecting Corrupted Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:47Saving Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6:48

12.1vi© 2011 AVEVA Solutions Ltd

Page 9: aveva p&id

AVEVA P&ID 12.1 User Guide

Data Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:1Exporting Data to an AVEVA P&ID Reports Database . . . . . . . . . . . . . . . . . . . . 7:1Data Validation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:1Points to Note. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:2

Transferring Data to and from AVEVA Instrumentation and AVEVA Electrical 7:2Exporting to AVEVA Instrumentation and AVEVA Electrical . . . . . . . . . . . . . . . . . . . . . . . . 7:2Importing from AVEVA Instrumentation and AVEVA Electrical . . . . . . . . . . . . . . . . . . . . . . 7:3

Exporting to PDMS Schematic Databases. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:3Importing VPE Workbench Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:4Importing Instrument Tag/Loop Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:4Importing Equipment Design Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:5Importing I/O Address Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:5

Exporting Data to a VPE Workbench Database . . . . . . . . . . . . . . . . . . . . . . . . . 7:6Data Validation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:7Points to Note. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:7

Exporting Data to AVEVA NET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:8Exporting to an ISO 15926 File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:9Transferring Data to and from Excel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7:10

AVEVA P&ID Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:1Preliminary Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:1Specifying Project Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:1Creating Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:1Upgrading AutoCAD Drawings to AVEVA P&ID Drawings . . . . . . . . . . . . . . . . . . . . . . . . . 8:1Upgrading Items from old Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:1Opening a Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:2Adding a Title to a Drawing and entering Drawing Sheet Attributes . . . . . . . . . . . . . . . . . . 8:2

Implementing Configuration Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:6Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:6Updating Equipment Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:7Updating PipeTags. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:8Updating Spec Driven Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:9Convert Project Label Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:10

Changing AVEVA P&ID Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:11Turning Automatic Flow Arrows On and Off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:11Turning Automatic Tracing On and Off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:11Turning Automatic Breaks On and Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:12Turning the Display of Ports On and Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:12

12.1vii© 2011 AVEVA Solutions Ltd

Page 10: aveva p&id

AVEVA P&ID 12.1 User Guide

Selecting the Style of New Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:13Selecting the Tracing Style of New Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:13Selecting the Style of New Signal Lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:14

Inserting Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:15Inserting Symbols - General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:15Inserting Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:17Inserting Electrical Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:19Inserting Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:21Inserting Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:22Inserting Instrument Valves (Control Valves) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:24Inserting Inline Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:29Inserting Instruments (Balloons). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:31Inserting Flow Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:34Inserting Miscellaneous Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:36Inserting Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:38Inserting Unassigned P&ID Database Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:40Inserting Unassigned VPE Workbench Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:41

Drawing Pipes and Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:45Drawing Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:45Inserting Unassigned P&ID Database Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:46Drawing Process Links. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:48Changing Pipe Styles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:53Applying Tracing to Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:54Drawing Signal Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:54Changing Signal Line Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:55Breaking Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:56Merging Pipes, Branches and Signal Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:57Splitting Pipes and Signal Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:57Splitting off Branches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:59Reversing Pipe and Signal Line Flows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:60Adding Pipe and Signal Line Segments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:61Merging Pipe Segments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:62Deleting Pipe and Signal Line Segments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:62Changing the Length of Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:63Adding Elbows to a Line. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:64Changing Pipes to Branches and Branches to Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:66Changing the Owning Pipes of Branches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:67Connecting Pipes to Nozzles and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:68Disconnecting Pipes from Nozzles and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:69

12.1viii© 2011 AVEVA Solutions Ltd

Page 11: aveva p&id

AVEVA P&ID 12.1 User Guide

Labelling Symbols and Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:70Labelling - General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:70Labelling Using the Non-Modal Properties Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:72Labelling Equipment (with or without Trim) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:74Labelling Electrical Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:79Adding Equipment Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:82Labelling Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:83Labelling General Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:86Labelling Port Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:91Labelling Inline Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:93Labelling Pipe Destination Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:96Creating Instrument Loops. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:98Labelling General Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:99Labelling System I/O Connections, Interlocks and Logic Boxes . . . . . . . . . . . . . . . . . . . 8:105Labelling I/O Rockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:107Labelling Revision Triangles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:110Creating Pipe Groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:114Labelling Pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:116Labelling and Connecting Pipe Flags. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:122Labelling Reducers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:128Labelling Breaks and Inline Breaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:133Adding Pipe Destination Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:135Labelling with Data from the P&ID Data Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:138Refreshing P&ID Data Grid Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:140Editing Non-AVEVA P&ID Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:140Labelling Typical Items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:141Replacing Tags with Tags in the Automatic Tag Format . . . . . . . . . . . . . . . . . . . . . . . . . 8:143Setting a Pipe Label as the Main Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:144Changing the Association of a Pipe Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:146Adding Notes to Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:147Globally Editing Labels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:148Setting Symbols to Inherit Label Data from a Manually Selected Pipe . . . . . . . . . . . . . . 8:151Switching off Label Data Inheritance from Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:152Labelling Items with UDAs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:152Removing UDAs from Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:154

Modifying Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:156Copying Drawing Objects and Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:156Moving Drawing Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:162Mirroring Drawing Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:164Stretching Drawing Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:165

12.1ix© 2011 AVEVA Solutions Ltd

Page 12: aveva p&id

AVEVA P&ID 12.1 User Guide

Rotating Drawing Objects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:167Deleting Drawing Objects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:168Exchanging Individual Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:169Exchanging Symbols Globally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:171Moving Items to the Non-Plot Layer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:171Drawing Revision Clouds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:172Changing the Colours of Multiple Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:173

Data Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:183Checking for Corrupted Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:183Exporting Data to a P&ID Reports Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:183Connecting to a P&ID Reports Database. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:187Opening a P&ID Reports Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:188Synchronising Data with a VPE Workbench Database . . . . . . . . . . . . . . . . . . . . . . . . . . 8:189Synchronising Multiple Drawing Data with VPE Workbench . . . . . . . . . . . . . . . . . . . . . . 8:199Connecting to a VPE Workbench Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:200Disconnecting from a VPE Workbench Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:201Labelling with VPE Workbench Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:202Inserting Tables of VPE Workbench Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:204Refreshing VPE Workbench Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:205Transferring Data from AVEVA Instrumentation and AVEVA Electrical. . . . . . . . . . . . . . 8:206Transferring Data to PDMS Schematic Databases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:208Publishing Data to AVEVA NET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:209Exporting Data to ISO 15926 Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:210Exporting Data to Excel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:212Editing P&ID Data in an Excel Spreadsheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:215Importing Data from Excel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:218Exporting Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:223

Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:226Creating Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:226Regenerating the Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:228Creating Item Associations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:228Show Associations between Items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:229List Item Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:230Assigning a New Branch Id to a Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:232Viewing and Editing Pipe Entity Sequences. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:232Deleting Error Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:235Recovering Project Configuration Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:235

Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:1AVEVA P&ID Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:1

12.1x© 2011 AVEVA Solutions Ltd

Page 13: aveva p&id

AVEVA P&ID 12.1 User Guide

PID.MLN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:1

Output File Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:8Drawing Details - .drg file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:8Equipment Information - .equ file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:9Nozzle Information - .noz file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:10Instrument Loops - .ilp file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:10In-Line Non-Valves - .inv file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:10Process Connected Instrument Information - .ipc file. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:12Remote Instrument Information - .irm file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:13In-Line Valves Information - .ivl file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:14System Output Information - .isy file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:15Pipe Information - .pip file. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:16Pipe Item Information - .pit file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:16Notes Information - .nte file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:17Link Connectivities Information - .con file. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:17User-Defined Attributes Information - .usd file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:17Valve Port Information - .por file. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:18Monitor File - .mon file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:18

AVEVA P&ID Item Types and Label Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:18Pipes, Trim and Process Links Item Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:18Signal Line Item Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:18Tracing Item Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:19Symbol Item Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:19Label Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:21

AutoCAD Defaults set by AVEVA P&ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:24The ISO15926 (Version 3.2.0) Schema Specification . . . . . . . . . . . . . . . . . . . . 9:25Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:25XML Model Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:25Shared Attribute Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:28Element Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:31

The ISO15926 (Version 3.3.3) Schema Specification . . . . . . . . . . . . . . . . . . . . 9:94Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:94Model Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:94Shared Attribute Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:100Element Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:102

Format of the Excel Interface Spreadsheet . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:173The Spreadsheet Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:173Item Worksheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:173Drawing Data Worksheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:174

12.1xi© 2011 AVEVA Solutions Ltd

Page 14: aveva p&id

AVEVA P&ID 12.1 User Guide

NEW Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:174Insertable and Updateable Fields. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:174Validated Rows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:175

Setting up AVEVA P&ID to Connect with VPE Workbench . . . . . . . . . . . . . . 9:176Installing the VPE Middle Tier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:176Configuring the AVEVA P&ID Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:179Synchronising. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:180Batch Loading data to VPE Workbench. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:181

Setting up PDMS to Connect with P&ID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:182

12.1xii© 2011 AVEVA Solutions Ltd

Page 15: aveva p&id

AVEVA P&ID 12.1 User GuideOverview

1 Overview

1.1 About this User GuideThis user guide is for AVEVA P&ID 12.1.

The sections of the guide, and their content, are as follows:

Overview An overview of this user guide and of AVEVA P&ID.

Project Configuration Information on the configuration requirements at the start of a project, and those that may be necessary from time to time during the project.

Principles and Concepts Recommended drawing practices and background information on the operation of AVEVA P&ID.

The Graphical User Interface Information on the Engineering and Symbol Explorers, drawing page features, toolbars, menus and other aspects of the GUI.

Upgrading AutoCAD Drawings Procedures for using the AVEVA P&ID Drawing Upgrade Utility and AVEVA P&ID facilities to upgrade “dumb" AutoCAD drawings to "intelligent" AVEVA P&ID drawings.

Drawing P&IDs A guide to the generating P&IDs, with links to the appropriate detailed procedures.

Data Transfer Information on transferring data to and from AVEVA P&ID.

AVEVA P&ID Procedures Step-by-step instructions on carrying out AVEVA P&ID procedures for creating, editing, and exporting data from P&IDs.

Appendices Data on commands, file formats, item and label types, and the AutoCAD defaults used by AVEVA P&ID.

1.2 Overview of AVEVA P&IDAVEVA P&ID is an AutoCAD 2011 (64-bit) based application that enables the creation of intelligent P&IDs quickly and accurately. As a user inserts engineering symbols, and draws flow lines in AVEVA P&ID engineering intelligence is embedded in the AutoCAD drawing that identifies the items and the connectivity between them. Engineering tag information or labels, such as Equipment, Pipeline and Instrument identifiers can be added as the items

12.11:1© 2011 AVEVA Solutions Ltd

Page 16: aveva p&id

AVEVA P&ID 12.1 User GuideOverview

are created, or later to suit the progressive development of P&IDs and the engineering data available at the time.

The AVEVA P&ID Graphical User Interface (GUI) comprises a project explorer displaying lists of the Lines, Equipment and Instruments on the drawing, plus symbol libraries, customised menus and toolbars and properties dialog style dialog boxes for entering engineering tags or labels, which integrate smoothly with the AutoCAD display and software.

Information is validated online as it is entered into AVEVA P&ID by a conformance check against validation lists.

1.2.1 Interfaces with other ApplicationsAVEVA P&ID Reports is an engineering database fully integrated with P&ID. Item data can be exported to AVEVA P&ID Reports from P&ID drawings. AVEVA P&ID Reports can be used to add to, edit and manage this data between imports from AVEVA P&ID, use this data to create custom reports and queries in Excel, and to manage pipes that span multiple P&IDs. Data in a P&ID Reports database can be viewed in the P&ID Data Grid and used to label drawings.

Data can be saved directly into PDMS Schematic databases in the AVEVA PDMS Schematic Model Manager. Feedback from such PDMS load activities is captured and displayed in the P&ID user interface. The content of a Schematic database can be viewed in the P&ID Data Grid and the data used to label drawings.

AVEVA P&ID can export instrument data and electrical equipment data to AVEVA Instrumentation (AI) and AVEVA Electrical (AE), and drawings containing the exported data can be viewed in the AI and AE core applications. A stockpile of Instruments created in AI and equipment created in AE can be viewed in the P&ID Data Grid and can be inserted into the P&ID drawings, and item data used to label drawings.

Engineering tag information and connectivity from each drawing can be synchronised with data in AVEVA VPE Workbench, where the engineering items are automatically created or revised.

As data is transferred from the P&IDs to VPE Workbench a logical Plant Connectivity Model (PCM) is created and maintained automatically, that identifies all the Lines, Equipment and Instruments on the project and the Line connectivity between items and the ownership implied by the P&ID connections. Once the PCM has been populated engineers can review the P&ID changes and Issue this information for detailed engineering, where the P&ID data forms the basis of their engineering datasheets, project reports, and schematics.

Once detailed engineering design data has been entered into VPE Workbench and Released by other groups of engineers, this data can be referenced, displayed on the P&ID and automatically updated when it changes. This ensures data consistency between the design information and the drawings.

1.3 Features of AVEVA P&IDAVEVA P&ID provides the designer with a flow diagram development system which has the following features:

• A Graphical User Interface (GUI) that includes and supports the Microsoft Office 2010 Fluent User Interface. Familiarity with the GUI enables users to concentrate on the features provided and hence reduce the learning periods.

12.11:2© 2011 AVEVA Solutions Ltd

Page 17: aveva p&id

AVEVA P&ID 12.1 User GuideOverview

• Fast Performance and Graphical Creation. When each entity is placed on a flow diagram by AVEVA P&ID, it is assigned an engineering type reference which determines its 'behaviour' (new items are assigned a type reference at the outset).

• Both object driven (select object(s) then select command to apply to object(s), and command driven (select command then object(s) to which the command is to be applied) methods of drawing can be utilised.

• Intelligent 'labels' as engineering item tags are overlaid on graphics. The 'labels' can be added to items as they are created or later when project data becomes available, hence preventing bottlenecks in flow diagram production.

• Online validation of intelligent labels as they are placed on the flow diagram from project data entered into VPE Workbench and exported, or by manually created project validation lists. It is possible to export the validation files from VPE Workbench if the flow diagram data is to be loaded back into that database.

• Project specific configuration including layer/level, line styles, symbol sets, tag formats and colour, allows conformity to client standards.

• Items that logically reside together (for example, items of equipment with nozzles) are associated together when placed by AVEVA P&ID.

• Data security is provided through AutoCAD's extensive programming capabilities and cannot be accessed without an application to do so.

• AVEVA P&ID can co-exist with AutoCAD with no change to the setup parameters for the underlying CAD software.

• Data can be transferred from P&ID drawings into AVEVA P&ID Reports databases where it can be edited and managed, and used to produce a range of reports in Excel format. Data in a P&ID Reports database can be viewed in the P&ID Data Grid and used to label drawings.

• Data can be saved directly into PDMS Schematic databases in the AVEVA PDMS Schematic Model Manager. The content of a Schematic database can be viewed in the P&ID Data Grid and the data used to label drawings.

• AVEVA P&ID can export instrument data to AVEVA Instrumentation (AI), and drawings containing the exported instrument data can be viewed in AI. Instruments created in AI can be viewed in the P&ID Data Grid and can be inserted into the P&ID drawings, and instruments data used to label drawings.

• AVEVA P&ID can export electrical equipment data to AVEVA Electrical (AE), and drawings containing the exported equipment data can be viewed in AE. Electrical equipment created in AE can be viewed in the P&ID Data Grid and can be inserted into the P&ID drawings, and equipment data used to label drawings

• Ability to work online with the VPE Workbench for two-way data transfers enabling flow diagram information to be exported to VPE Workbench and Pipeline, Instruments and selected Equipment design information can be referenced from the database onto the flow diagram for display and data consistency.

• Ability to work offline with the VPE Workbench database. P&IDs can be edited offline from the database and synchronized back into the project by connecting to VPE Workbench at any time.

• Data can be transferred automatically to an SQL database when it is entered or edited, or “manually” synchronized.

• Data can be exported to Microsoft Excel spreadsheets, where it can be edited. The edited data can then be imported back into AVEVA P&ID.

• Easy substitution of client symbols with no naming restrictions. • Ability to read in client drawings/designs or to scan them for use as backgrounds. • Ability, in conjunction with the AVEVA P&ID Drawing Upgrade Utility, to upgrade "dumb"

AutoCAD lines and blocks to "intelligent" AVEVA P&ID pipes and symbols.

12.11:3© 2011 AVEVA Solutions Ltd

Page 18: aveva p&id

AVEVA P&ID 12.1 User GuideOverview

12.11:4© 2011 AVEVA Solutions Ltd

Page 19: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2 Project Configuration

2.1 Upgrading Pipes and Symbols from old ProjectsA revised version of pipe lines that improved the performance and usability of the application considerably was introduced with AVEVA VPE P&ID 7.2 SP3.

For projects developed using previous versions of AVEVA P&ID, an upgrade of the pipes and symbols on the project drawings is required before the drawings can be used in AVEVA VPE P&ID 7.2 SP3 or AVEVA P&ID 12.0 or later.

It is mandatory to verify that all the pipes are valid in 7.2 SP2 (or previous 7.2 versions) before executing the upgrade process. This validation process can be executed by using the command “net validate all”.

It is also mandatory to Synchronise (see 8.8.5: Synchronising Data with a VPE Workbench Database) each of the legacy drawings to be upgraded, using the legacy version machine. This process must be successful and the output files generated must be kept in the Project Area (e.g. …\Vantage\...).

All the project files must then be copied to the 12.0 or later machine where the upgrade process will be continued.

Once the files are copied to the 12.0 or later machine, the project must be upgraded using the Project Wizard in the normal way. This process does not upgrade the pipes and the symbols but it upgrades the project from the legacy versions to the latest version.

The next steps are to upgrade the symbol library, and then run the AVEVA Legacy Project Upgrade Utility to upgrade the symbols and pipes on the project drawings.

2.1.1 Upgrading the Symbol LibraryThe upgrade procedure for symbols in the project symbol library is as follows:

1. In 7.2 SP3 and 12.0 or later, all symbols in the symbol must have ports. To upgrade the symbols in the symbol library by adding ports, access the Symbol Explorer, right-click on the lower pane and select the Upgrade Ports from the menu that is then displayed. Each project symbol is then upgraded in turn. Wait until the process is finished.

Note: Only the symbol files located in the \PMETSYM (Metric projects) or \PIMPSYM (Imperial projects) symbol folders, or in sub-folders in these folders, are included in the upgrade.

Note: If single connection symbols are included in the upgrade, it is recommended that they are checked afterwards to ensure that ports have been placed on the correct sides of the symbols. It is not always possible for the upgrade routine to detect which this is.

12.12:1© 2011 AVEVA Solutions Ltd

Page 20: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2. A log file is created in the project symbol folder that contains lists the symbols that were correctly upgraded, any errors that occurred, and warnings that single connection symbols were upgraded (and therefore should be checked). For example:

[C:\Aveva\P&ID\PROJECT\IPE\Autocad\Pmetsym\NV.DWG] [VLV] succesfully upgraded Error: Symbol not found in project area [WEVA] Warning: Symbol with single insertion point [C:\Aveva\P&ID\PROJECT\IPE\Autocad\Pmetsym\Line Fittings\FLAG2.DWG] [PFL]

The log files are best viewed in WordPad.3. To manually upgrade symbols, use the Symbol Editor.

2.1.2 Upgrading Symbols and Pipes on Drawings1. Once the symbol library has been upgraded, the existing symbols and pipes on the

projects can be upgraded from the revised symbol library. This is done using the AVEVA P&ID Upgrade Utility.

Note:• If upgrading symbols in a legacy project, the drawings must first be synchronised

(see 8.8.5: Synchronising Data with a VPE Workbench Database). The output files generate by the synchronisation process must be available in the AVEVA Data Path directory.

• The project .PRJ file must be available for selection (see below).• The INST.VAL, EQUIP.VAL and PID.SYM must be available in the Validation

directory.• It is recommended that the upgraded symbols are tested in an empty drawing

before proceeding to edit real project drawings.

Select AVEVA > P&ID > AVEVA P&ID Upgrade Utility > AVEVA P&ID Project Upgradefrom the Programs menu.

12.12:2© 2011 AVEVA Solutions Ltd

Page 21: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The AVEVA Legacy Project Upgrade dialog is then displayed.

2. In the Select Input Folder field, enter the folder in which the drawings to be upgraded are located, or press the Browse button and browse for the location. The full location and file name of each AVEVA P&ID drawing in the selected input folder is the listed in the dialog.

3. In the Select P&ID Project File field, enter the location and file name of the configuration file (.PRJ) of the P&ID project associated with the drawings, or press the Browse button and browse for the file.

4. In the Select Output Folder field, enter the folder in which the upgraded drawings are to be placed, or press the Browse button and browse for the location.

5. The utility may optionally be used to export data from drawings to XML files in ISO 15928 format. This data can subsequently be imported into AVEVA PDMS using Schematic Model Manager.

If this is required, check the ISO 15926 checkbox.6. In the Select ISO Output Folder field, enter the folder in which the XML files are to be

placed, or press the Browse button and browse for the location. 7. Select ISO 15926 schema version to be used, either 3.2 or 3.3.8. If all the P&ID drawings found in the input folder are to be upgraded (and optionally

have data exported from), select the Select All checkbox. If only certain drawings are to be upgraded and exported from, check or uncheck the Select File checkboxes for the individual drawings as required.

9. Select the Process button. The upgrade operation then takes place.

12.12:3© 2011 AVEVA Solutions Ltd

Page 22: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

10. When a drawing has been processed successfully, a green tick is displayed in its Progress field. A red cross is displayed if the drawing is processed with errors.

11. To stop the operation, select the Cancel button.12. Once a drawing has been processed, details of errors and warnings an be viewed by

selecting its View Log File button. 13. Close the utility by selecting the Exit button.

Once the symbols have been upgraded the next step is to upgrade pipes and process links.

12.12:4© 2011 AVEVA Solutions Ltd

Page 23: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.2 Project Options Overview AVEVA P&ID can be configured to suit project requirements by means of project options. These options are contained within the project catalogue file, <project>.prj, which resides in the working directory of the current project. The options in this catalogue are modified using the AVEVA P&ID Project Administration Program.

Project specific configurations can be established for directory paths, project numbers and units, pipe thickness and styles, and many others.

Most changes in the project configuration are applied to an existing drawing when it is loaded into the drawing editor, or when the Refresh Settings option in the AVEVA P&ID Group of the Home Tab is selected. See 8.2: Implementing Configuration Changes.

Some configuration changes, those that would significantly slow down the opening of drawings, must be triggered by the user after the drawing has opened.

Theoretically, changes can be made to the project catalogue configuration right up to the point of data synchronisation with VPE Workbench although this is undesirable. If several drawings have been created and such a change occurs, it is advisable to write a simple script file which loads each drawing, saves it, and unloads it.

Warning: Changes made to project options should be authorised in advance and the details documented, as these affect all other AVEVA P&ID users and can also affect work already completed. If changes made to the project configuration result in configuration conflicts that prevent a drawing from loading, use the Recovering Project Configuration Settings procedure to resolve this problem.

12.12:5© 2011 AVEVA Solutions Ltd

Page 24: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3 AVEVA P&ID Project Administration Program

2.3.1 IntroductionAVEVA P&ID can be configured to suit project requirements by means of various options set using the AVEVA P&ID Project Administration program. See 2.2: Project Options Overviewfor an overview of the use and impact of these options.

Most changes in the project configuration are applied to an existing drawing when it is loaded into the drawing editor, or when the Refresh Settings option in the AVEVA P&ID Group of the Home Tab is selected.. See 8.2: Implementing Configuration Changes.

If changes made to the project configuration result in configuration conflicts that prevents a drawing from loading, use the Recovering Project Configuration Settings procedure to resolve this problem.

The AVEVA P&ID Project Administration program is a separate application from AVEVA P&ID. It can be opened from the Project Administrator option in the AVEVA P&ID Groupof the Home Tab, or from a shortcut on the Programs menu (e.g. AVEVA Plant > Engineer > P&ID 12.1 > Projects > [Project Name] > Project Administrator [Project Name]), or from a desktop shortcut:

The LogIn dialog is displayed:

Enter the project login details for accessing the Administration program and press the OK button (these are set when the project is installed/upgraded but can be amended using the Project Database Configuration Category).

12.12:6© 2011 AVEVA Solutions Ltd

Page 25: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The password used if the Login as Administrator with password (SQL Server Security) option is selected is set using the User Access Configuration Category of the Administration program.

The following is then displayed:

The File menu consists of the following options: • Save: Saves project file settings for the current project. A toolbar button is also

available to perform this function. • Open: Used to browse for and open another project. Project settings are stored in files

with a suffix of .PRJ. A toolbar button is also available to perform this function. If a project is already open it must be closed by using the Close option.

• Close: Closes the settings dialogs for the current project. • Recent: Displays a list of recently opened projects. Double-click on a project to switch

to it. If a project is already open it must be closed by using the Close option.• Help: Opens a sub-menu from which the online help and "About" information can be

opened.• Application Event Log: Displays a dialog in which application events are listed.• Exit: Exits the application.

12.12:7© 2011 AVEVA Solutions Ltd

Page 26: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Project Catalogue Editor DialogDisplay the settings of a project by clicking the File tab (click on the File tab again to return to the File menu). The following is then displayed:

The dialog box consists of two distinct sections: • The Explorer • Configuration Category application pane

12.12:8© 2011 AVEVA Solutions Ltd

Page 27: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Explorer is used to navigate to the different Configuration Categories for which settings and data are to be configured.

Each Configuration Category is concerned with a different aspect of the project configuration. For example, Item Types, Signal Styles, Equipment, etc.

For some Configuration Categories, e.g. Drawing, information sub-categories are available, e.g. Grid, Labels and Layers etc. Expand or close a Configuration Category by clicking on the +/- boxes. For example:

As well as by using the Explorer, Configuration Categories may be selected from a menu accessed by clicking the title of the current Configuration Category.

12.12:9© 2011 AVEVA Solutions Ltd

Page 28: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Following selection of a Configuration Category, the relevant data and configuration parameters are displayed in the application pane.

The fields, checkbox etc in the application panes are used to change project settings. The majority of displayed data may be amended, and is validated on data entry where applicable.

Tables of data associated with a Configuration Category are displayed in grids. Grids are provided with standard facilities for grouping data by columns, pinning rows, re-ordering columns and filtering the displayed data (similar to those of the P&ID Data Grid - see 4.5.9: Configuring the Grid Layout).

A set of toolbars buttons is also provided to manage data in grids:

12.12:10© 2011 AVEVA Solutions Ltd

Page 29: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

These buttons provide the following functions:

• To create a new record in a grid, use the button. A dialog is then displayed in which the unique identifier of the record must be entered. The new record is then added to the grid.

• To move up and down the list of rows in order to edit existing entries, use the and

buttons.

• To delete a row, scroll to the row in question and select the button.

• To copy a row, scroll to the row in question and select the button. As each record must have a unique identifier, a dialog is then displayed in which the unique identifier for the record copy must be entered. The copied record is then added to the grid as a new row.

• To rename a row, scroll to the row in question and select the button. A dialog is then displayed in which the new unique identifier of the record must be entered.

Not all these button are active for every grid. Some are not applicable for some grids and are disabled.

The Configuration Categories are as follows: • Project Configuration Category• VPE Workbench Configuration Category• Project Database Configuration Category• P&ID Reports Configuration Category• Drawing Configuration Category • Item Types Configuration Category • Label Types Configuration Category • Text Styles Configuration Category • Symbols Configuration Category• List of Values Configuration Category • Pipes Configuration Category • Signal Styles Configuration Category • Tracing Configuration Category • Instruments Configuration Category

12.12:11© 2011 AVEVA Solutions Ltd

Page 30: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Equipment Configuration Category• Valves Configuration Category • Line Fittings Configuration Category• Nozzles Configuration Category• Offsheet Connector Configuration Category• Miscellaneous Configuration Category • Excel Interface Configuration Category• Spec Driven Configuration Category• User Defined Attributes Configuration Category• User Access Configuration Category• PDMS Integration Configuration Category• AI Integration Configuration Category• AVEVA NET Configuration Category• AE Integration Configuration Category

12.12:12© 2011 AVEVA Solutions Ltd

Page 31: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.2 Project Configuration Category

The Project Configuration Category is configured using a single application pane:

The application pane is divided into seven sections:

• Project Number Section The Project Number field is used to set the identifier of the project, and is established when the project is generated using the project wizard but can be changed if required. The project number provides security when a synchronisation with VPE Workbench procedure performed and prevents accidental transfers to the wrong project within VPE Workbench.

12.12:13© 2011 AVEVA Solutions Ltd

Page 32: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Project Units Section This section is used to specify two settings:

• The Drawing Units field displays the drawing units specified by the project wizard. Drawing units should never be changed once the project is under way, as they affect the size of drawings, line thicknesses, symbols etc in AutoCAD, and so the field is read-only.

• Select either the Metric or Imperial Label Units button. This setting controls whether sizes entered as part of item labels are in metric or imperial units, and which list of values file is used to validate the entries. Label units may be changed part way through a project as required. Drawings will be automatically updated with the new units when they are reloaded.

Note: Changes to drawings resulting from the label units being changed are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded. See 8.2.5: Convert Project Label Units.

• Project Paths Section During the procedure for installing AVEVA P&ID, directory paths are set up. These can be edited using the fields in the Project Paths section. The Browse buttons adjacent to each field may be used to search for a new file path.

• The P&ID Installation Path field is used to specify the directory into which the AVEVA P&ID software was installed.

• The AVEVA Data Path field is used to specify the output directory into which drawing output files are saved. AVEVA P&ID also imports instrument loop numbers from VPE Workbench via this directory, if the project is configured to do so.

• The Validation Directory Path field is used to specify the location of the files that contain on-line validation data (lists of valid values against which item labels are checked on entry). These validation files can be exported from VPE Workbench, in which case they should not be edited locally.

• The Project Tag Data Path field is used to specify the location of the Access database to which data could be exported in previous versions of AVEVA P&ID. This path is used when upgrading a project to the current version.

• The Standard Metric Symbol Pat is used to specify displays the directory in which standard metric symbols are located.

• The Project Metric Symbol Path field is used to specify the directory in which project symbols are located.

• The Standard Imperial Symbol Path field is used to specify the directory in which standard imperial symbols are located.

• The Project Imperial Symbol Path field is used to specify the directory in which project imperial symbols are located.

• The Helpfile Path field is used to specify the location of the Online Guide. • The Monitor File Path field is used to specify the location of the monitor file generated

each time an export takes place.• The Drawing Location field is used to specify the directory in which project drawings

are located. Drawings can only be opened from this folder and from sub-folders in this folder.

• The Assemblies Path field is used to specify the directory in which assemblies are located.

12.12:14© 2011 AVEVA Solutions Ltd

Page 33: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• When P&ID data is transferred to VPE Workbench, a copy of the P&ID drawing may be made available for use by AVEVA Model Management. In the Save Path field, specify the interface directory into which the copies of the P&IDs are to be saved

If the project is set to use Metric drawing units, the Standard Imperial Symbol Path and the Project Imperial Symbol Path fields will be 'greyed out'. If the project is set to use Imperial drawing units, the Standard Metric Symbol Path and the Project Metric Symbol Path fields will be 'greyed out'.

• Symbol Search Priority Section It is possible to create a project symbol with the same name as a standard symbol supplied with the installation. If this occurs, it is necessary to determine which directory, and which version of the symbol, is to be searched for first and be the preferred version for the project.

See the 2.3.10: Symbols Configuration Category topic for details of symbol creation.

Select either the Project or Standard button to determine the symbol search priority. The search priority also affects which directory any assemblies are created under, either standard or project.

It is recommended that in normal circumstances the search priority is set to Project so that project assemblies are created in the project directories.

• Update Graphical Changes Automatically on Start Up SectionIf drawings are to be automatically updated when opened for the first time after changes have been made to graphical Project Administration settings, check the Update checkbox.

If the user is to prompted to choose whether or not the changes are to be implemented when opening the drawings, uncheck the checkbox.

The checkbox controls how changes to the followings settings are implemented:

Pipe Tags

Equipment Tags

Pipe Styles

Signal Styles

Item Type properties changes (Layers and Colours)

12.12:15© 2011 AVEVA Solutions Ltd

Page 34: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.3 VPE Workbench Configuration Category

The VPE Workbench Configuration Category using the main VPE Workbench Configuration Category pane and the Tables sub-category:

• VPE Workbench Configuration Category Pane• Tables Sub-Set

12.12:16© 2011 AVEVA Solutions Ltd

Page 35: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• VPE Workbench Configuration Category Pane

Note: See also 9.8: Setting up AVEVA P&ID to Connect with VPE Workbench.

12.12:17© 2011 AVEVA Solutions Ltd

Page 36: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The application pane is divided into four sections.

- Synchronise Settings Section

In the VPE Config File field, specify the location of the .INI configuration file of the VPE Workbench installation with which the AVEVA P&ID project is to interface. This may be a copy of the original file located on the VPE Workbench middle tier server.

In the VPE Service Path, enter the path to the EngAPIService component that will handle the transfer of data to VPE Workbench. This should be located on the VPE Workbench middle tier server. This path must include the port (which must be open) to be used for data transfers. The default port is 8080.

- Explore Database Unassigned Settings Section

If the unassigned items in the VPE Workbench Database, i.e. those that have not yet been included on a project P&ID, are to be displayed in the Engineering Explorer check the Show Unassigned Items in Explorer checkbox.

- VPE Settings Section

In the Publisher Folder field, specify the folder into which drawings are published when loading to the selected VPE Workbench project.

In the Database Project field, select the VPE Workbench project with which the AVEVA P&ID project is to interface. The list of projects available in this field is taken from the specified .INI file (see above).

The Export to VPE Workbench checkbox is used to set the default setting (checked or unchecked) of the Export Data to Publishing Area checkbox on the Synchronise dialog (see Synchronising Data with a VPE Workbench Database).

When a drawing is loaded to a VPE Workbench 5.8 or later project, e-mails can be sent to users of that project to inform them of this. Enter the user names and e-mail addresses of the VPE Workbench project users in the grid at the bottom of the section.

If a new e-mail recipient is to be entered, use the button to create a new row. Enter the user name of the new recipient in the dialog that is then displayed:

User names cannot be edited. The user name row must be deleted and re-entered with a new user name.

12.12:18© 2011 AVEVA Solutions Ltd

Page 37: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Batch Load to Workbench Section

This section is used to load/publish data from multiple drawings into a VPE Workbench database.

The Select Drawings to Publish pane lists all the drawings that were either individually synchronised using the Synchronising Data with a VPE Workbench Database procedure, or had output files generated using the Synchronising Multiple Drawing Data with VPE Workbench procedure.

The procedure for loading/publishing depends on whether drawing data is being exported to a VPE Workbench 5.8 (or later) project, or a VPE Workbench 5.6 or 5.7 project.

Loading/Publishing to VPE Workbench 5.8 or later Projects

Note that drawings can optionally be loaded/published to a VPE Workbench 5.8 project as part of the Synchronise procedure.

If the project is a VPE Workbench 5.8 or later project, select the drawings to be loaded in the Select Drawings to Publish pane and load/publish them by pressing the > button. The drawings are moved to the Publishing Area pane and loaded into the VPE Workbench project.

A message is displayed in the messages pane at the bottom of the section to indicate the successful loading of the drawing data to the publishing area, for example: "905675 File Successfully Loaded to Staging Area".

Use the >> button to load/publish all the listed drawings.

Loading/Publishing to VPE Workbench 5.6 or 5.7 Projects

If the project is a VPE Workbench 5.6 or 5.7 project, check the Using Workbench Legacy Version (5.6/5.7) checkbox.

A connection to the VPE Workbench Database must then be established, if this has not already been done. Press the Login button. The VPE Workbench Log In dialog is then displayed.

For information on the use of this dialog and other options for connecting the a VPE Workbench database see the Connecting to a VPE Workbench Database procedure.

Once the connection has been made, select the drawings to be loaded in the Select Drawings to Publish pane and use the > button to move them to the Publishing Area pane. Use the >> button to select all the listed drawings for loading.

Start the load by pressing the Load button.

12.12:19© 2011 AVEVA Solutions Ltd

Page 38: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Progress, error and warning messages are displayed in the message pane at the bottom of the section. Once loaded, the drawings are removed from the Publishing Area pane.

To view the log file of messages generated while loading/publishing, press the View Log button. The file then opens in Notepad.

To delete all the drawings currently in the publishing area, press the Clear button. A message is then displayed requesting that the deletion be confirmed. Press Yes to continue with the deletion.

• Tables Sub-SetThe Tables pane is used create and maintain the definitions of tables of VPE Workbenchdata that can be placed on AVEVA P&ID drawings:

- Existing Tables Section

This section lists all existing table definitions.

12.12:20© 2011 AVEVA Solutions Ltd

Page 39: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To create a new table, select the Add Table button. Enter the name of the new table in the dialog that is then displayed:

The name of the new table definition is then added to the list. Continue by entering the settings of the table definition in the Table Details Section (see below). Note that the Table Details Section will initially be populated with the settings entered for the previous table definition, or if no table definition has been created previously, with default settings.

• To delete a table definition, select it and the Delete Table link. • To rename a table definition, select it and the Rename Table link. Enter the new name

of the table definition in the dialog that is then displayed, and press the OK button. • To edit an existing table definition, select it from the list. The current settings for the

selected table definition are then displayed in the Table Details Section and may be changed as required.

- Table Details Section

Specifying the Appearance of a Table:

1. The Colour field defines the colour of the table (both the table borders and the table text).

2. The Browse button adjacent to the Colour field is used to select the colour. On selection of the button, the colour selection dialog box is displayed:

The colour can be selected by the following three methods: • By selection of one of the colours shown in the palette.

12.12:21© 2011 AVEVA Solutions Ltd

Page 40: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• By double clicking the Assume Owner Colour hyperlink. Not applicable for tables.• By double-clicking on the Assume By Layer hyperlink. Tables will automatically

assume the colours of the layers they are inserted into, as set on the Layers Sub-Set the Drawing Configuration Category.

• By manually entry into the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in Colour field.

3. The X and Y fields are used to specify the coordinates that the table will be placed at on drawings.

4. The Text Style field is used to specify the style of the table text. Select the required style from the list. Text styles are set up using the Text Styles pane. The default will be the ROMANS style, which is supplied with the product and does not need to be set up.

5. The Row Height field is used to specify the height of the table rows. 6. The Text Height field is used to specify the height of text in the table.

Specifying the Type of Data a Table will display:

The API Group Set, API Group and API Group Set Argument fields are used to specify the type of data that is to appear in the table:

1. Select the API Lookup button. If a connection to the project database has not been established, the AVEVA P&ID Logon dialog is then displayed:

2. Complete the Username and Password fields, and select the required project from the drop-down list in the Project field.

3. Select the OK button. The API Group Lookup dialog is then displayed. 4. If a connection to the database has already been established in this session, this dialog

is displayed when the API Lookup button is selected.

12.12:22© 2011 AVEVA Solutions Ltd

Page 41: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

5. Select the API Group and the Group Set which contain the required data, and press the Set button.

6. The API Group Set and API Group fields in the Table Details Section are then populated with the selected Group and the Group Set.

By default, tables will only be populated with data relating to items that are on the drawing on which the tables are placed. Alternatively, the table or tables that data is to be extracted can be specified in the API Group Set Argument field.

For example, if the following is entered:

Drawing_ID="9999"

Data will be extracted from the project drawing with the ID of 9999. If data is to be extracted from multiple drawings, multiple arguments may be entered.

Setting up Table Columns:

Once the type of data has been specified, the columns that the table is to consist of, and the data that is to populate these columns is set up using the grid section.

Adding a Column:

1. To add a column, select the button and enter the column name in the dialog that is then displayed. A new row is then added to the grid. Each row in the grid is used to set up one table column.

2. The Column field displays the number of each column. These numbers control the order in which columns are displayed in the table, i.e. the column with the lowest number will be the first column on the left.

The Column field is read-only. To change the order of columns, use the copy and delete facilities.

3. In the Caption field, enter the text that is to appear as the heading for the column. 4. In the Designator field, select the required designator. When the table is placed on a

drawing, the designator is replaced with the appropriate value. The list of designators is restricted to those in the selected API Group and the Group Set.

5. In the Width field, enter the width of the column. 6. The Text Align field is used to specify the alignment of the text in the column. Enter the

appropriate code (1 to 9):

1 = Top Left

12.12:23© 2011 AVEVA Solutions Ltd

Page 42: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2 = Top Centre

3 = Top Right

4 = Middle Left

5 = Middle Centre

6 = Middle Right

7 = Bottom Left

8 = Bottom Centre

9 = Bottom Right

If no value is entered, the alignment defaults to Middle Left.

12.12:24© 2011 AVEVA Solutions Ltd

Page 43: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.4 Project Database Configuration Category

The Project Database Configuration Category is configured using the Settings sub-category:

- SQL Server Settings Section

Project data is stored in an SQL database. This section is used to enter details of the SQL server the project database is to use. These details are initially specified when a project is installed or upgraded, but they may subsequently be amended here.

Enter a valid server name in the Server Name field.

Depending on whether the database is to be logged into using Windows Authentication or SQL Server Authentication, select either the Use Windows Integrated Security (Windows Authentication) option or the Login as Administrator with password (SQL Server Security) option.

If the second option is selected, enter the login details in the Admin Login Name and Password fields. This login must be a valid SQL Server Administrator account login.

12.12:25© 2011 AVEVA Solutions Ltd

Page 44: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Test that the entered details are valid by selecting the Test Connection button. A message will then be displayed indicating whether or not the connection details are valid. For example:

- Online Editing Section

If label data is to be saved automatically to an SQL database when it is entered, check the Save to database on Update checkbox. The saved data is used when validating the uniqueness of tags in a project. See 6.13.4: Label Validation across all Project P&IDs

When a project is upgraded, in order for Spec Driven data and functionality to be available (see 2.3.23: Spec Driven Configuration Category), the project database schema must be updated by selecting the Upgrade Specdriven Database Schema - Upgrade button.

12.12:26© 2011 AVEVA Solutions Ltd

Page 45: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.5 P&ID Reports Configuration Category

The P&ID Reports Configuration Category is configured using the main P&ID Reports Configuration Category pane and the Settings sub-category:

• P&ID Reports Configuration Category Pane• Settings Sub-Set

• P&ID Reports Configuration Category Pane

A P&ID Reports database is supplied with the product (PidReports). By default, AVEVA P&ID will be set to export data to this database. To create a new, blank P&ID Reports database, press the Create button. A new database will then be created.

The filename of the new database will be "PidReports_<project name>_<incremented number>.

The P&ID Reports Server Name field displays the name of the SQL server, as specified on the Project Database Configuration Category.

The P&ID Reports Database field displays the name of the current P&ID Reports database. Select a different database from the list available from this field if required. The list consists of all P&ID Reports databases created for the project.

12.12:27© 2011 AVEVA Solutions Ltd

Page 46: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Settings Sub-Set

- P&ID Reports Settings

UDA values are displayed in AVEVA P&ID Reports on the UDA tab. If UDA values are also to be displayed on the same tabs as the items they are associated with (assuming there are fields available for them to be displayed in), check the Merge UDA Values checkbox.

The Update P&ID Reports after Synchronize checkbox controls the default setting of the Export to PID Reports checkbox on the Synchronise dialog. If the Update P&ID Reports after Synchronize checkbox is checked, then the default setting of the Export to PID Reports checkbox is checked, and vice versa.

The Update and Consolidate P&ID Reports Database after Synchronize checkbox controls the default setting of the Export & Consolidate Database checkbox on the Synchronise dialog. If the Update and Consolidate P&ID Reports Database after Synchronize checkbox is checked, then the default setting of the Export & Consolidate Database checkbox is checked, and vice versa.

If the Add P&ID Drawing Details to Database checkbox is checked, the comments regarding an export that may be entered in the Description dialog during the export process are added to the P&ID Reports database.

12.12:28© 2011 AVEVA Solutions Ltd

Page 47: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Line Consolidation Section

This section is used to select which line properties are to be compared when attempting to consolidate lines which are present on multiple P&IDs when they are transferred into P&ID Reports. Both the properties of lines and the properties of the components on the ends of lines may be compared.

As required, check the checkboxes in the First / Last component fields and/or Line fields sections.

Note that the unique pipe validation fields specified in the P&ID project settings are compared regardless of these settings.

When the fields of two lines with unique pipe validation tag do not match, the lines are not consolidated and warning message is displayed in log tab of P&ID Reports.

12.12:29© 2011 AVEVA Solutions Ltd

Page 48: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.6 Drawing Configuration Category

The Drawing Configuration Category is divided into five sub-categories: • Grid Sub-Set• Labels Sub-Set • Layers Sub-Set • Settings Sub-Set • Validation Sub-Set

12.12:30© 2011 AVEVA Solutions Ltd

Page 49: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Grid Sub-Set

The fields in the Grid application pane are used to set up the dimensions and other elements of the drawing grid.

The application pane is divided into two sections.

- Drawing Frame Settings Section

This section contains the following settings: • Drawing Length and Height fields. These fields specify the length and height of the

drawing.

12.12:31© 2011 AVEVA Solutions Ltd

Page 50: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Horizontal Start, Mid and End Distance fields are used to specify the horizontal dimensions of the drawing frame grid.

• The Horizontal Start field is used to set the distance from the left-hand edge (0,0) of the sheet to the left-hand edge of the frame.

• The Horizontal Mid field is used to set the length of AVEVA P&ID grid squares within the frame.

• The Horizontal End field is used to set the distance from the right-hand edge of the frame to the right-hand edge of the sheet.

• The Vertical Start, Mid and End Distance fields are used to specify the vertical dimensions of the drawing frame grid.

• The Vertical End field is used to set the distance from the top edge of the sheet to the top edge of the frame.

• The Vertical Mid field is used to set the height of AVEVA P&ID grid squares within the frame.

• The Vertical Start field is used to set the distance from the bottom edge of the frame (0,0) to the bottom edge of the sheet.

Only objects within the limits of drawings, as specified here using Drawing Length and Height fields, will be validated.

- Grid Settings Section

This section contains the following settings: • Vertical Grid Direction. This is a group of two buttons - Up and Down. It is only possible

to have one button selected at a time. Depending on the button selected, the grid will increment from the top or the bottom along the Y-axis.

• Horizontal Grid Direction. This is a group of two buttons - Left and Right. It is only possible to have one button selected at a time. Depending on the button selected, the grid will increment from the left or from the right along the X-axis.

• Vertical and Horizontal Grid Type. This is a group of two buttons - Letters and Numbers. It is only possible to have one button select at a time. Depending on the button selected, the X and Y-axes are assigned either letters or numbers.

• Grid Spacing field. This field is used to specify the size of the AutoCAD grid spaces. Note that the AutoCAD grid is a separate feature from the AVEVA P&ID grid (see below).

• Snap Spacing field. This field is used to specify the size of the snap spacing. Usually, the snap spacing is set first and then the grid spacing is set to match the snap spacing. AVEVA P&ID grid and snap definitions will override AutoCAD settings so snap and grid settings must always be defined in the project configuration to suit the symbol set in use.

• Grid Letters to Ignore field. This field is used to specify the grid letters to ignore, for example I and O, which may be confused with one and zero. List the letters to be excluded, using commas as separators, or enter NONE.

The AutoCAD drawing grid, and the AVEVA P&ID drawing grid are two distinct features. The AutoCAD drawing grid is a standard AutoCAD feature switched on by pressing the GRID button at the bottom of the P&ID drawing pane. The AutoCAD drawing grid is a grid of dots laid over the P&ID as a drawing aid. The Grid Spacing field described above is used to specify the size of the grid squares.

The AVEVA P&ID drawing grid is used to give each item on a P&ID a location identifier derived from the letters and/or numbers of the grid axes e.g. G5. When P&ID data is transferred to VPE Workbench, the location identifier of each item is also transferred. This is to help VPE Workbench users find items more easily if they have to refer back to a P&ID.

12.12:32© 2011 AVEVA Solutions Ltd

Page 51: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Please note that all grid calculations performed by AVEVA P&ID assume that the border sheet has its bottom left corner at the 0,0 AutoCAD coordinate. If this is not the case grid references will not be correct, and some items could report to be off of the grid.

• Labels Sub-Set

The Labels sub-category is used to configure how project drawings themselves (as opposed to items on these drawings) are labelled with a drawing title.

The Labels application pane is divided into two sections.

- Drawing Labels Section

This section contains the following settings: • If the design area of drawings is required as part of the drawing title label, and is also to

be used as a prefix for instrument/equipment labels, check the Design Area from Title Block used for Instrument Label Field 1 checkbox.

• If the project number is to be part of the drawing title label, check the Place Project Number Label as part of Drawing Title checkbox.

• Number of Design Area Labels to place, Number of Drawing Number Labels to place and Number of Project Number Labels to place. Several labels may be placed for Drawing Area, Drawing Number and Project Number when using the Adding a Title to a Drawing and entering Drawing Sheet Attributes procedure. Enter the number of labels required for each in the three fields provided.

12.12:33© 2011 AVEVA Solutions Ltd

Page 52: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- VPE Drawing Attributes Section

The VPE Drawing Attributes section is used to select VPE Workbench data with which to label drawings in the project, for example information regarding systems that items on the drawings are allocated to.

The section contains Default X Pitch and Default Y Pitch fields and a grid with three columns - Designator, Default X Pitch and Default Y Pitch. Enter or edit the Designator name in the first field, the Default X Pitch value in the second field and the Default Y Pitch value in the third field.

The X and Y pitch values control the spacing between VPE Workbench attribute data where there is more than one such attribute labelling a drawing. Change the default values as required.

- Creating a new VPE Drawing Attribute

If a VPE Drawing Attribute is to be created, select the button. The following dialog box is then displayed:

Enter a unique value for the VPE Drawing Attribute designator and press the OK button.

The dialog box will be closed and the entered value will be displayed in the Designator column. The Default X Pitch and Default Y Pitch will automatically default to the values entered in the corresponding fields above the grid.

To edit a designator name, select the button and enter the new value in the dialog that is then displayed.

To edit the Default X Pitch and Default Y Pitch values scroll to the row in question and click. This will activate the cursor within the selected row, and the value may then be edited.

12.12:34© 2011 AVEVA Solutions Ltd

Page 53: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Layers Sub-Set

AVEVA P&ID is supplied with layers already set up for pipes, equipment, instruments, labels and a non-plotting layer. The Layers application pane is used to edit these layers and to add new layers as required.

- Creating a new Drawing Layer

If a layer is to be created, select the button. The following dialog box is then displayed:

Enter a unique value for the drawing layer and press the OK button.

The dialog box will be closed and the entered new value will be displayed in the Drawing Layer column. The colour code will be set automatically to the default value, but may be amended. See below for details

To edit a drawing layer name, select the button and enter the new value in the dialog that is then displayed.

- Entering a Colour Code

Scroll to the row in question. The colour box dialog button is displayed:

12.12:35© 2011 AVEVA Solutions Ltd

Page 54: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

On selection of the button, the colour selection dialog box is displayed:

The Colour Code can be selected by the following methods: • Selection of one of the colours shown in the palette • By manually entering the Colour Code field

The Assume Owner Colour and Assume ByLayer options are not applicable in this case.

Following selection, press OK. The selected colour code will then be displayed in the grid.

If the colour of an existing layer is changed, drawings will be updated with the new colour when they are reloaded.

12.12:36© 2011 AVEVA Solutions Ltd

Page 55: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Settings Sub-Set

The Settings application pane is divided into two sections.

The pane also includes the Entity selected is added to the current selection set checkbox. This checkbox is used to specify the method used to select multiple objects on drawings.

If the checkbox is unchecked (the default setting), to select multiple drawing objects, press the Shift key while selecting each of the objects. If the Shift key is not pressed when an object or objects are selected, any previously selected objects are de-selected.

If the checkbox is checked, it is not necessary to press Shift in order to select multiple objects. Each object is added to the set of selected objects as it is selected. To remove objects from the set of selected objects, press Shift and select them.

- User Defined Sheet Attributes Section

This section is used to enter the field names for the Sheet Attribute fields on the Advanced Drawing Properties sheet. These fields are used to enter drawing sheet properties in addition to those of the drawing title.

As required, enter meaningful field titles in the ten fields provided.

12.12:37© 2011 AVEVA Solutions Ltd

Page 56: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The first field on the Advanced Drawing Properties sheet will always display the Design Area attribute, though the field name may still be changed if required.

The attributes entered in the Advanced Drawing Properties sheet are not used to label the drawing sheet themselves, but the values entered may be properties that are common to many items on the drawing, for example the design area, and may be "inherited" into label fields of these items. This inheritance is set up for each category of item (e.g. equipment) using the appropriate Configuration Category pane.

- Drawing History Settings

Check the Show Drawing History checkbox if the Description dialog is to be displayed automatically when saving changes to a drawing and during the Synchronisation process. The dialog is used to enter comments regarding changes to the drawing.

- Drawing Labels Settings

This section is used to specify the positions of labels that may be used to label the drawing.

The grid lists all the label types of the drawing properties under the Label Type heading. The description of each of the label types is displayed under the Description heading. Label types and descriptions cannot be edited.

If a label is to be placed in its default position on the drawing, select N from the list in the Fix Position field. If a label is to be placed at specified coordinates, select Y.

Note: Some drawing properties are not placed on drawings by default, for example minimum and maximum line and loop numbers. However, if coordinates are entered for them, they will be placed at these coordinates.

Enter the X and Y coordinates of the label in the X and Y fields.

For the drawing title label type (XDT) an Y offset may also be entered. This is because drawing title label may consist of multiple lines (up to 5). The Y offset specifies the vertical gap between each line. If any drawing title is to consist of more than one line, enter a number in the Y Offset (XDT Only) field. Note that the offset number should be negative, as second and subsequent lines should be placed below the first line.

12.12:38© 2011 AVEVA Solutions Ltd

Page 57: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Validation Sub-Set

This sub-category is used to specify the permitted format of entries into selected drawing properties fields.

In the fields provided, enter the following characters as required:

For example, if AaN is entered for the Design area Attribute field, when a user is completing this field in the Drawing Properties dialog, the first character must be an uppercase letter, the second a lower case letter, and the third a number.

The Advanced Format Options dialog is available from the button adjacent to each field.

Code Description

A Upper Case Alpha Character [A-Z]

a Lower Case Alpha Character [a-z]

M Mixed Case Alpha Character [A-Z, a-z]

F Upper Case Free Character [A-Z, 0-9, white space]

f Lower Case Free Character [a-z, 0-9, white space]

X Mixed Case Free Character [A-Z, a-z, 0-9, white space]

N Numeric Character [0-9]

12.12:39© 2011 AVEVA Solutions Ltd

Page 58: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To test how the validation will work in practice, make an entry in the Test Data field of the Test tab, and press the Test button. A message will be displayed indicating whether or not the test data would be a valid entry.

To directly edit the regular expression that comprises the validation entry, select the Advanced tab. The expression is displayed in the Regular Expression field and may be amended as required. For help on editing Regular Expressions, click on the help link displayed on this tab.

12.12:40© 2011 AVEVA Solutions Ltd

Page 59: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.7 Item Types Configuration Category

The Item Types Configuration Category is divided into two sub-categories: • Standard Sub-Set• Signal Sub-Set

• Standard Sub-Set

This sub-category is used to set default drawing layers and colours for item types other than signal line item types. These are edited using the Signal sub-category. When an item is inserted into a drawing, it will be placed on the default layer in the default colour, unless another layer and colour are specified for that particular item as it is inserted. Layers are configured on the Drawing - Layers Sub-Set.

If the item type of an item is not in the list on this pane, it will be placed on the current layer, in the default colour of that layer. The item colour will also be set to the default colour of the layer it is placed on if no colour is specified when the item is inserted. Item types that break into lines can alternatively be set to have a colour entry of 300. Such items will automatically assume the colour of the line that they are being inserted into. If the colour of an item is required to default to the drawing layer colour, set the colour to 256.

The application pane consists of a grid with four columns - Item Type, Drawing Layer, Colour and Description. The Item Type and Description are not editable; edit the Drawing Layer name in the second field, and the colour of the layer in the third field.

12.12:41© 2011 AVEVA Solutions Ltd

Page 60: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Changing a Drawing Layer

If a Drawing Layer is to be changed, scroll to the row in question and double click. The following list of values selection box will then be displayed:

Choose the required value from the list and press Enter to save the selection.

- Entering a Colour Code

Scroll to the row in question. The colour box dialog button is displayed:

On selection of the button, the colour selection dialog box is displayed:

The Colour Code can be selected by the following four methods: • Selection of one of the colours shown in the palette • By double clicking the Assume Owner Colour hyperlink. Items will automatically

assume the colours of the owning items, e.g., the colours of the lines they are inserted into. When there is no owning item, they will be set to the default colour.

12.12:42© 2011 AVEVA Solutions Ltd

Page 61: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• By double-clicking on the Assume By Layer hyperlink. Items will automatically assume the colours of the layers they are inserted into, as set on the Layers Sub-Set the Drawing Configuration Category.

• By manually entering the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in the grid.

• Signal Sub-Set

This sub-category is used to set default drawing layers (levels) and colours for signal line item types. It can also be used to create new signal line item types.

To change the drawing layer or colour of a signal line item type, proceed as described above for standard item types.

To add a new signal line item type, select the button. The following dialog box is then displayed:

All signal line item type identifiers are three-letter codes beginning with "S". The "S" is added automatically to the beginning of the entered identifier. Enter the second and third characters and press OK.

12.12:43© 2011 AVEVA Solutions Ltd

Page 62: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The dialog box will be closed and the new item type will be displayed in the grid. Select a default drawing layer and change the default colour as required.

Signal item types identifiers cannot be edited. The item type row must be deleted and re-entered with a new identifier.

12.12:44© 2011 AVEVA Solutions Ltd

Page 63: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.8 Label Types Configuration Category

The Label Types application pane is used to set up the default layers, colours, text height and other text options of types of labels.

The application pane is divided into two sections.

• Label Details SectionThis section contains the following settings:

• Select either the Metric or Imperial Label Units button. Labelling units may be changed part way through a project; drawings will be automatically updated with the new units when they are reloaded (these buttons perform the same function as those on the Project pane).

• The Label Null Character field is used to choose the null character which is used during item labelling. During labelling, if data is not yet known, the null character, for example a question mark, may be put in its place. This may then be replaced with the "real" data at a later stage. If the null character is changed, the next time a drawing including the null character is loaded, the previous null character will be replaced with the new one.

• If text styles are not in use on the project (see below), the Label Font field is used to specify the font of all labels. The default font is ROMANS, a standard AutoCAD font, but any other available font may be entered. The label font may be changed part way through a project. Drawings will be automatically updated with the new font when they are reloaded.

• If text styles are to be used, check the Use Text Style checkbox. Select the default style in the Default Text Style field. Text styles are set up using the Text Styles pane. The

12.12:45© 2011 AVEVA Solutions Ltd

Page 64: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

initial default will be the ROMANS style which is supplied with the product and does not need to be set up.

• If unlabelled nozzles are to result in a warning being displayed during synchronisation, the Nozzle Error-Balloon Placement checkbox must be checked.

• If unlabelled reducers are to result in an error being displayed during synchronisation, check the "Reducer Not Labelled' Error-Balloon Placement checkbox.

• If unlabelled ports on port valves are to result in an error being displayed during synchronisation, check the Port Error-Balloon Placement checkbox. Port valves are valves that have ports whose sizes are inherited from attached pipes or may be individually labelled with their sizes if they are connected to a process link.

• Label Types Grid Section This section is used to set up the default layers, colours, text height and other text options of types of labels.

• The default justification and/or rotation of text can be overridden when a label is placed. If the label type of a label is not in the list in this section, it will be placed on the current layer/level, in the default colour of that layer/level, with a text height of 2.5mm or 1/8".

• If a label is given a colour entry of 300 it will assume the colour of the owning item. • This section consists of a grid that includes the following columns - Label Type,

Drawing Layer, Text Height, Text Options and Description. The Label Type and Description are not editable. Edit the Drawing Layer name in the second field, the Text Height in the third field, and the colour of the layer in the fourth field. See below for details on setting up these options.

• The Text Options field is used to specify the justification of the label, and whether or not prompts will be received to specify text height and rotation when the label is inserted. See below for details on setting up these options.

• If text styles are to be used, select text styles for labels from the list in the Text Style field, or leave set to the default style selected in the Default Text Style field (see above).

• Changing a Drawing Layer If a Drawing Layer is to be changed, scroll to the row in question and double click. The following list of values selection box will then be displayed:

Choose the required value from the list and press Enter to save the selection.

12.12:46© 2011 AVEVA Solutions Ltd

Page 65: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Entering a Colour CodeScroll to the row in question. The colour box dialog button is displayed:

On selection of the button, the colour selection dialog box is displayed:

The Colour Code can be selected by the following three methods: • Selection of one of the colours shown in the palette • By double clicking the Assume Owner Colour hyperlink. Labels will automatically

assume the colours of the owning items. When there is no owning item, they will be set to the default colour.

• By double-clicking on the Assume By Layer hyperlink. Labels will automatically assume the colours of the layers they are inserted into, as set on the Layers Sub-Set the Drawing Configuration Category.

• By manually entering the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in the grid.

• Editing Text Options Scroll to the row in question. The label options box dialog button is displayed:

12.12:47© 2011 AVEVA Solutions Ltd

Page 66: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Label Options selection dialog box is then displayed:

Select the required options and press OK. The selected options will then be displayed in the grid as comma delimited text e.g. M, N, N. The first letter indicates the justification setting, the third letter the rotation setting. The second letter is an indicator related to a legacy setting that is no longer used.

If Y is entered in the Rotation field, the text rotation is specified by the user when labels of this type are inserted.

12.12:48© 2011 AVEVA Solutions Ltd

Page 67: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.9 Text Styles Configuration Category

The Text Styles application pane is used to set up text styles. These styles are subsequently applied to label types using the Label Types application pane. When an item is labelled, the label uses the text style applied to the label type.

• Adding a Style

If a style is to be added, select the button. The following dialog box is then displayed:

Enter a style name and press the OK button. The dialog box will be closed and the entered new style name will be displayed in the grid.

Style names cannot be edited. The style row must be deleted and re-entered with a new name.

• Defining Text Styles 1. Allocate a type face for each new text style. 2. If a font file is to be used, enter Y in the Use Font File column, and select the file in the

Font File column. 3. If a "Big Font" is to be used, enter Y in the Use Big Font column, and select the file in

the Big Font File column. 4. Only fonts available to the AutoCAD installation may be selected. To check the

available fonts, check the available font files, for example at C:\Program Files\AutoCAD 2008\Fonts.

5. If the text style is to be bold or italic, enter Y as required in the Bold and/or Italic columns.

6. As required, enter the width of the text in the Text Width column.

12.12:49© 2011 AVEVA Solutions Ltd

Page 68: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.10 Symbols Configuration Category

The Symbols pane is used to update the definitions of all the symbols that can be inserted into a AVEVA P&ID drawing.

• When the product is installed, a standard set of symbols is installed with it. Also installed is a default project. This includes symbol data as part of the project catalogue which includes settings that define the behaviour of all the standard symbols. A copy of symbol data is automatically copied into the directory structure of a new project whenever a new project is generated.

• A project can be granted access to the standard set of symbols via the appropriate Standard Symbol Path, as displayed on the Project pane of the Administration program. In this way, a common set of symbols can be made available to all projects.

• The standard symbol set can be changed simply by redrawing or replacing the standard symbols using AutoCAD. The default symbol data should also be changed to reflect this by the use of this screen in the administrator, replacing the symbol names of the supplied set with those of the replacement set.

• If project specific symbols are required in addition to the standard symbol set, these can either be drawn in AutoCAD or preferably by using the Symbol Editor facility, and placed as appropriate in the project symbol directory.

• The symbols grid of the Symbols pane provides facilities for adding definitions of project symbols to the project, and for editing them as required. These new definitions are added to the project copy of the symbol data in the project catalogue.

• The pane in fact provides facilities for editing the settings of all symbols that are available to the project, including standard symbols. Since these changes are saved and stored in the project catalogue, changes made to the settings of standard symbols for a project do not change the default settings for these symbols as stored in the default project.

The application pane is divided into four sections.

12.12:50© 2011 AVEVA Solutions Ltd

Page 69: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Import Symbols Section This section contains two hyperlinks - Import/Re-Import ALL Standard Symbols and Import/Re-Import ALL Project Symbols.

On selection of Import/Re-Import ALL Standard Symbols, the following dialog box is called:

On selection of Import/Re-Import ALL Project Symbols, the following dialog box is called:

Select the Yes or No buttons as required.

These options are used to replace the standard or project symbols currently listed in the symbols grid with those that are actually currently stored in the standard and project symbol directories respectively.

This may be required if, for example: • The standard symbols set has been changed since the project was created, and the

project needs to be updated to reflect this. • A large number of new project specific symbols have been placed in the project symbol

directory and need to be made available to the project. Usually it would be quicker to individually add definitions of new project symbols using the facilities available from the symbols grid, but if there are enough new symbols, it might be quicker to use the import facility.

After an import takes place, the settings of the imported symbols will have to be entered in the symbols grid, as the only fields that will be completed with anything other than default settings will be the Symbol Name fields.

See below for details of completing the symbol grid and its facilities.

• Symbol Viewer Section This section contains two hyperlinks - Open Symbol Viewer Window… and Close Symbol Viewer Window…

12.12:51© 2011 AVEVA Solutions Ltd

Page 70: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

On selection of Open Symbol Viewer Window…, a window is opened in which the symbol currently selected in the symbol grid is graphically displayed. The Symbol Viewer is refreshed with the appropriate symbol if another symbol is selected from the symbol grid.

The window can be moved and 'docked' within the application pane.

On selection of Close Symbol Viewer Window…, the viewer window is closed.

Note: If using AutoCAD 2009, the AutoCAD background colour must be set to black in order to correctly display symbols in the Symbol Viewer Window. To do this, open the Symbol Editor Window (see below), and from the Tools menu, "Options Display" and then the "Colours" icon. Set the background colour to black, then save the Symbol Editor Window and close it.

• User Defined Attributes SectionAfter User-Defined Attributes (UDAs) have been added to symbols or edited using the Symbol Editor, in order to implement these changes to all project drawings, or to a selection of project drawings, the Refresh UDAs facility must be used.

Click the Upgrade UDAs In Drawings hyperlink. The Refresh UDAs dialog is then opened. See below for more details.

• Symbol Grid SectionThe Symbols grid is used to manage the properties of symbols.

See below for guidance on entering symbol data.

12.12:52© 2011 AVEVA Solutions Ltd

Page 71: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Adding a New Symbol

If a symbol definition is to be added to the project, select the button. The following file dialog box is then displayed:

• If a new symbol definition is to be created and added to the project, press the New button. Enter the name of the new symbol in the Symbol Name field. Select a P&ID type and enter a description in the PID Type and Symbol Description fields. Browse for the location for the new symbol file via the button adjacent to the File/Directory path field.

Note: In the case of pipe flags (off-sheet connectors), the symbol name must end with either -IN or -OUT depending on whether the flag symbol is intended to represent a connector into drawings or out of drawings.

• If an existing symbol definition is to be added to the project, one that has already been drawn, perhaps in another project, press the Existing button. Then browse for the appropriate symbol drawing file using the button adjacent to the File/Directory path field. Select a P&ID type and enter a description in the PID Type and Symbol Description fields.

When all details of the symbol have been entered, press OK. The dialog box will be closed and the values of the added symbol will be displayed in the grid. New symbols can now be drawn using the Symbol Editor, and Existing symbols edited.

Symbol names cannot be edited. The symbol row must be deleted and re-entered with a new name.

• Entering Symbol Data • Column 1: Symbol Name • Column 2: P&ID Type • Column 3: Fixed Size or User Defined • Column 4: Insertion in Pipes, Links and Signal Lines • Column 5: Symbol Length • Column 6: Break Offset

12.12:53© 2011 AVEVA Solutions Ltd

Page 72: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Column 7: Number of Insert Points • Column 8: Graphical Creation Angle • Column 9: Graphical Trace Around • Column 10: Trace Width • Column 11: Item Type • Column 12: Valve Type • Column 13: Valve Actuator Type • Column 14: Instrument Location • Column 15: PDMS Type • Column 16: PDMS Sub Type

Note: In the case of port valves, most of the data described below is derived automatically from the physical attributes of the symbol drawing. The only attribute that may need to be set is the Number of Insert Points.

- Column 1: Symbol Name

The column may contain a maximum of 32 characters and holds the name of the block defined by the user.

- Column 2: P&ID Type

Decide which AVEVA P&ID item type the new block falls into. If in doubt, look at the default blocks provided with the installation. Once decided, enter the 3 character type in this column in capital letters e.g. VLV-valve. The AVEVA P&ID type dictates the block's behaviour and labelling capabilities in the drawing. If uncertain, leave the symbol out and do this later. Establish whether it will appear in the instrument or valve list, if not, leave the symbol off the drawings completely. Do not insert it as a Miscellaneous item type otherwise it may be necessary to remove it, purge the drawing, reinsert the correct symbol and label it.

- Column 3: Fixed Size or User Defined

This setting determines whether the block can be re-sized or not. The only items which can be re-sized are equipment items of AVEVA P&ID types EQU, EQV and EQE

Select 1 for Fixed or 2 for User Defined for these types only. Set to 0 for all other types.

- Column 4: Insertion in Pipes, Links and Signal Lines

This setting governs whether a block may break into a pipe, signal line or process link. Enter 1 for No or 2 for Yes. Take extra care when creating new symbols such as reducers and insulation; some only need to overlay the pipe and some actually need to break into a pipe in order to be exported correctly.

12.12:54© 2011 AVEVA Solutions Ltd

Page 73: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Column 5: Symbol Length

Any block that is connected to or breaks into a line needs a length to be defined for it. This is because AVEVA P&ID needs to know the length of the corresponding break to be made in the line. Enter the length of the block, if applicable, as a decimal number e.g. 8.0. If 1 was the entry in column 4, enter 0.0 for null. Avoid entering lengths which divide by 2 to give an odd number, as this then forces the user to have a snap spacing of 1, which is too small to be workable.

- Column 6: Break Offset

The distance from the insert point of the block to the start of the break in the line, pipe etc. Enter 0.0 for null if the entry in Column 4 was 1 (No). Alternatively, enter the offset as a decimal number, e.g. 2.0. If the offset is not half the length, AVEVA P&ID will allow the picking of an offset distance moving in a left to right direction.

12.12:55© 2011 AVEVA Solutions Ltd

Page 74: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Column 7: Number of Insert Points

The block may have one or more insert points depending on what it consists of e.g. spec break, reducer, handwheel. Enter 1 if the block should assume the angle of the pipe into which it is breaking or 0 degrees. Enter 2 if the program should ask the user for a second point to show the angle.

Note: The number of insertion points is significant when upgrading project symbols developed before AVEVA VPE P&ID 7.2 SP3. Symbols with single insertion points may have to be upgraded manually. Refer to 2.1: Upgrading Pipes and Symbols from old Projects for details.

- Column 8: Graphical Creation Angle

The graphical creation angle must be taken into account when creating blocks.

The basic rule is that AVEVA P&ID subtracts the graphical creation angle from the angle of the pipe so that the group always aligns itself with the pipe upon insertion and hence looks "correct".

12.12:56© 2011 AVEVA Solutions Ltd

Page 75: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

A graphical creation must be stated when creating 2-way, 3-way, or angled valves dependent on the insertion point.

Enter the graphical creation angle if applicable, as a decimal figure e.g. 90.0. This number can easily be changed using the Project Administration program if it is discovered that on insertion the angle is incorrect. Often the easiest way of understanding this requirement is to change the angle and make an insertion; go back to the Project Administration program and keep altering it until the desired result is achieved.

- Column 9: Graphical Trace Around

Enter 2 if the block is an inline item and should be traced around. Enter 1 if the symbol should not be traced around.

- Column 10: Trace Width

Enter a decimal number to denote the width of the tracing. Enter 0.0 for null.

- Column 11: Item Type

This prompt is shown when a symbol is inserted. It is a description of the block which may be up to 32 characters in length.

12.12:57© 2011 AVEVA Solutions Ltd

Page 76: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Column 12: Valve Type

For instruments only, the type of valve e.g. globe. Enter up to 32 characters or NONE if this column does not apply.

- Column 13: Valve Actuator Type

For instruments only, the type of actuator on a valve e.g. diaphragm. Enter up to 32 characters or NONE if this column does not apply.

- Column 14: Instrument Location

For instruments only, the location of the instrument e.g. panel, rack etc. Enter up to 32 characters and NONE if this column does not apply.

- Column 15: PDMS Type

Field used by AVEVA Model Management and PDMS.

- Column 16: PDMS Sub Type

Field used by AVEVA Model Management and PDMS.

12.12:58© 2011 AVEVA Solutions Ltd

Page 77: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Updating UDAsAfter User-Defined Attributes (UDAs) have been added to symbols or edited using the Symbol Editor, in order to implement these changes to all project drawings, or to a selection of project drawings, the Refresh UDAs facility must be used.

Click the Upgrade UDAs In Drawings hyperlink. The Refresh UDAs dialog is then opened.

In the Select Drawing Folder field, select the folder in which the drawings to be updated are located, or press the Browse button to browse for the required folder.

All the AVEVA P&ID drawings in the selected folder are then listed.

To select a drawing to be updated with the UDA changes, check the appropriate Select File checkbox. To select all drawings, check the Select All checkbox.

When the required drawings have been selected, select the Process button. A warning message is then displayed advising the user to ensure that none of the drawings selected

12.12:59© 2011 AVEVA Solutions Ltd

Page 78: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

are currently being edited. Assuming that this is the case, select the OK button. The selected drawings are then updated with the UDA changes.

The Progress field will indicate the progress of the operation.

To cancel the process, select the Quit button.

12.12:60© 2011 AVEVA Solutions Ltd

Page 79: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To view details of the process once it is complete, press the View Log button. The log of the process will then be displayed in Notepad.

The log will list for each selected drawing, which UDAs have been added or deleted and the symbols to they have been added/deleted to/from.

To close the Refresh UDAs dialog, select the Exit button.

12.12:61© 2011 AVEVA Solutions Ltd

Page 80: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.11 List of Values Configuration Category

The List of Values set application pane is used to edit the lists of values available when labelling items. A default set of lists of values is provided with the product. If online validation is active (as described later in the Miscellaneous Configuration Category topic), data entered during labelling is checked against these lists, with only values in these lists being valid. User-defined lists can also be created.

12.12:62© 2011 AVEVA Solutions Ltd

Page 81: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The application pane includes a drop down list:

Select the required validation data set from this list. The content of the data set is then displayed in the grid below and may be edited as required. For more information see Principle and Concepts - Validation.

The list also includes any user-defined lists of values. See below for the procedure for creating user-defined lists of values.

The list also includes the AlphaNumeric/Numeric equivalent Size list. This is used to specify the numeric equivalents of alphanumeric size values, to be used when data is exported, for example to a Schematic database.

In the above example, the alphanumeric size value of 20A has a numeric equivalent of 20. As a result, when size values of 20A are exported, they will automatically be converted to 20.

• Adding a Value

If a value is to be added, select the button. The following dialog box is then displayed:

12.12:63© 2011 AVEVA Solutions Ltd

Page 82: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Enter a unique value and press the OK button. The dialog box will be closed and the entered new value will be displayed in the grid. Enter a description in the adjacent Description field.

To edit a value, select the button and enter the new value in the dialog that is then displayed.

Note: In order for reducers to automatically change orientation, so that the wide end is always connected to the larger pipe size and the narrow end is always connected to the smaller pipe size, the list of values for sizes used on the project (Metric Sizes or Imperial Sizes) must set up sorted from smallest size to largest size.

• Editing Pipe Styles Data entered on this application pane includes the pipe styles that are valid for the project. Select Pipe Styles from the drop down list. Update existing values, or add new pipe styles as required. If the style of a pipe that exists on a drawing is changed, the drawing will be updated with the new style when it is reloaded.

1. In the Multi-Line (Y/N) field enter Y if the new style is to consist of multiple lines, otherwise enter N. For further details on creating multi-lines, refer to AutoCAD documentation.

2. In the Line Type field, select the AutoCAD line type that the new style is to be based on. 3. Enter a meaningful description in the Description field. 4. If the change the drawing layer that pipes of a pipe style are to be placed on, double

click on the appropriate field. Choose the required value from the list of values that is then displayed and press Enter to save the selection.

5. To change the colour of a pipe style, double click on the appropriate field. The colour box dialog button is displayed:

On selection of the button, the colour selection dialog box is displayed:

12.12:64© 2011 AVEVA Solutions Ltd

Page 83: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Colour Code can be selected by the following three methods: • Selection of one of the colours shown in the palette • By double clicking the Assume Owner Colour hyperlink. Items will automatically

assume the colours of the owning items. When there is no owning item, they will be set to the default colour.

• By double-clicking on the Assume By Layer hyperlink. Labels will automatically assume the colours of the layers they are inserted into, as set on the Layers Sub-Set the Drawing Configuration Category.

• By manually entering the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in the grid.

• Creating User-Defined Lists of ValuesTo create a user-defined list of values, select this button in the User-Defined List of Values

section of the pane: .

The following dialog box is then displayed:

Enter the name of the new list of values and press the OK button. The dialog box will be closed and the name of the list will be displayed in the grid in the User-Defined List of Values section. Note that the application automatically prefixes the names of user-defined lists of values with "USERLOV_".

12.12:65© 2011 AVEVA Solutions Ltd

Page 84: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The LOV File Name field displays the filename of the list. This is automatically generated and cannot be changed.

Once a list of values has been created, it can be selected from the list of list of values at the top of the pane. The values that comprise the list can then be entered as described above.

The toolbar buttons in the User-Defined List of Values section work in the same way as those in the upper section, as described above. Use these to rename lists of values, sort the lists in the grid, delete lists etc.

To edit a list of values name, select the button and enter the new value in the dialog that is then displayed.

12.12:66© 2011 AVEVA Solutions Ltd

Page 85: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.12 Pipes Configuration Category

The Pipes Configuration Category is divided into four sub-categories: • Settings Sub-Set • Labels Sub-Set • Validation Sub-Set • Automatic Tag Format Sub-Set

12.12:67© 2011 AVEVA Solutions Ltd

Page 86: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Settings Sub-Set

(continued on next page)

12.12:68© 2011 AVEVA Solutions Ltd

Page 87: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

12.12:69© 2011 AVEVA Solutions Ltd

Page 88: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The fields in this application pane are used to set up the configuration properties of pipes.

The application pane is divided into twelve sections.

- Settings Section

If items are to inherit some of their properties from the pipe that they are owned by, the Inherit Item Labels from Owner Pipe checkbox must be checked.

If pipe connection size data is to be output when synchronising with a VPE Workbench database, ensure that the Pipe Size Connection Output checkbox is checked.

Select the default style of process links in the Default Process Link Style field.

Select the default style of instrument process links (also known as "Legacy" process links) in the Default Instrument Process Link Style field.

- Breaks Section

This section contains the following settings: • The 'Automatic Breaks ON' checkbox governs whether pipes break automatically or not

when crossed by another pipe. If the checkbox is not checked, warnings are given that junctions have not been formed when pipes cross each other. If the checkbox is checked, pipelines drawn crossing other pipes will be drawn with breaks positioned according to the setting of the Break Pipe Direction field (see below).

• The Break Distance field is used to set the width of the gap created in the pipe when it is broken by another. This distance separates the break symbols.

• Depending on which Break Pipe Direction button is selected, Horizontal and Vertical, pipes will either break vertically or horizontally, assuming the Automatic Breaks ON checkbox has been checked.

• The Symbol Name field is used to specify the break symbol inserted when a pipe is broken, e.g. LBRK. The symbol name is selected from a drop down list.

• The Symbol Layer field is used to specify the layer on which the break symbols reside. The layer name is selected from a drop down list.

• The Symbol Colour field defines the colour of the break symbol inserted when a pipe is broken.

The Browse button adjacent to the Symbol Colour field is used to select the colour. On selection of the button, the colour selection dialog box is displayed:

12.12:70© 2011 AVEVA Solutions Ltd

Page 89: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Colour Code can be selected using the following methods: • Selection of one of the colours shown in the palette • By double clicking the Assume Owner Colour hyperlink. Items will automatically

assume the colours of the owning items, e.g., the colours of the lines they are inserted into. When there is no owning item, they will be set to the default colour.

• By double-clicking on the Assume By Layer hyperlink. Items will automatically assume the colours of the layers they are inserted into, as set on the Layers Sub-Set the Drawing Configuration Category.

• By manually entering the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in the Symbol Colour field.

- Flow Arrows Section

This section contains the following settings: • The Automatic Arrows checkbox governs the presence or absence of flow arrows at

the direction change points of pipes. • The Symbol Name field specifies which flow arrow symbol is used. The symbol name is

selected using the drop down list.

- Values to Remember from Last Pipe Edit Section

The section contains fifteen checkboxes - Size, Fluid/Service, Number, Area, Specification, Insulation (Table), Insulation (Index), Insulation (Condition), Paint Code, Tracing (Number), Tracing (Size), Tracing (Type), Project Field 1, Project Field 2 and Project Field 3.

A project can be configured so that a value entered in a field in a Properties dialog is "remembered" by the same field when that Properties dialog is accessed again when labelling another, previously unlabelled, item of that type.

If, for example, the functionality is switched on for the pipe Number field, and a pipe is labelled with a value of "001". The next time a pipe is labelled for the first time, when the Properties dialog for this item is opened, the Number field will automatically be completed with the value "001". This can be replaced by another value if required. This new value will then be the "remembered" value for the pipe Number field.

This functionality is switched on and off for individual Properties dialog fields by checking and unchecking the checkboxes in this section.

- Label Validation Across P&IDs Section

The project may be set to check that all pipe labels in all P&IDs in a project are unique. • Select the Prevent button if users are to be prevented from entering project duplicate

pipe labels. If this is attempted, an error message is displayed and the duplicate label may not be placed on the P&ID.

12.12:71© 2011 AVEVA Solutions Ltd

Page 90: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Select the Warn button if users are to be warned if they enter project duplicate pipe labels. The entry of duplicate labels is permitted in this case, but an error message will be displayed on the P&ID, and will accompany the pipe label data when transferred to VPE Workbench.

• If no uniqueness validation of pipe labels across P&IDs is required, select Ignore button. Duplicate pipe labels may be entered in different P&IDs in this case. Duplicate pipe labels are still not permitted in the same P&ID.

Duplicate pipe labels are not regarded as duplicates if the pipes in question are connected with cross-sheet connectors.

Note that if the Prevent or Warn options are set, a connection to the VPE Workbenchdatabase must be established before labels can be edited. This is because in order to check the uniqueness of labels across a project, AVEVA P&ID refers to the VPE Workbenchdatabase.

- Size Consistency Section

If the synchronisation process is to check that nozzle and pipe sizes match and to report any mismatches as errors, check the Enforce Nozzle and Pipe Size Match checkbox.

If this checkbox is checked, any such mismatches must be corrected before the nozzles and pipes in question can be successfully synchronised.

- Populate Specification in Database Section

If specification values are not going to be entered into the P&IDs, but populated in VPE Workbench instead, check the Populate Spec in Database checkbox.

- Inheritance Section

The values of pipe attributes may be inherited from the sheet attributes entered on the Advanced Drawing Properties sheet. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design area. The inheritance facility enables all items to inherit these common values. The attributes of items that do not share these common values may subsequently be edited manually using their properties sheets.

The Inheritance section is used to select which pipe attributes are to inherit values from which sheet attributes. As required, select for each pipe attribute the sheet attribute field from which values are to be inherited.

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

- Reducer Setting Section

From the Reducer Label Format list, select the direction in which reducer labels are to be orientated.

12.12:72© 2011 AVEVA Solutions Ltd

Page 91: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

If "Flow Direction" is selected, the first part of the label (i.e. the first diameter) is positioned on the upstream side of the reducer and the second part of the label on the downstream side of the reducer, e.g.:

If "Largest size first" is selected, the first part of the label is placed on the wider side of the reducer, the second part on the narrower side:

If "Smallest size first" is selected, the first part of the label is placed on the narrower side of the reducer, the second part on the wider side:

Note: In order for this functionality to work correctly, the list of values for sizes used on the project (Metric Sizes or Imperial Sizes) must set up sorted from smallest size to largest size. Lists of values are set up using the List of Values Configuration Category.

- Cascade Settings Section

By default, when the properties of parent pipe label are edited, any changes to these properties may immediately be reflected in the labelling of the branches off that pipe.

If required, this cascading of changes may be disabled for selected properties. If this is required, check the Disabled Cascading in Branches checkbox.

12.12:73© 2011 AVEVA Solutions Ltd

Page 92: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To select the property fields to be excluded from cascading, select the Browse button adjacent to the Select Fields to Disable field. The Select Fields to Disable Cascading dialog box is then displayed:

Select the fields to be disabled from the list of values and then select the OK button. The Select Fields to Disable field will then list the numbers representing the selected fields.

Note: Fields specified for unique validation (see the Labels Sub-Set below) will still be cascaded regardless of these settings.

- Legacy Settings Section

Check the Use Legacy Process Link checkbox if the pre-AVEVA VPE P&ID 7.2 SP3 type of process links are to be used (PLK item type). These are known as "Legacy" or instrument process links.

If this checkbox is not checked (default setting), process links are drawn as pipes (i.e. as branches between main pipes and offline items - PMA item type) in the process link pipe style.

- Synchronise warning settings or unconnected items Section

If, when a drawing is synchronised, a warning message is to be displayed on the drawing for “unconnected” items, i.e. items for which owner details are not available, check the Display owner warning checkbox.

12.12:74© 2011 AVEVA Solutions Ltd

Page 93: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Labels Sub-Set

(continued over)

12.12:75© 2011 AVEVA Solutions Ltd

Page 94: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The fields in this application pane are used to set up the pipe label configuration format.

The application pane is divided into eleven sections.

- Main Pipe Label Colour Section

The Main Pipe Label Colour field defines the colour of the pipe label that is selected in the pipe label set to represent the main values of the pipe.

12.12:76© 2011 AVEVA Solutions Ltd

Page 95: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Browse button adjacent to the field is used to select the colour. On selection of the button, the colour selection dialog box is displayed:

The Colour Code can be selected using the following methods: • Selection of one of the colours shown in the palette • By double clicking the Assume Owner Colour hyperlink. Labels will automatically

assume the colours labelled items. When there is no owning item, they will be set to the default colour.

• By double-clicking on the Assume By Layer hyperlink. Labels will automatically assume the colours of the layers they are inserted into, as set on the Layers sub-category of the Drawing Configuration Category.

• By manually entering the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in the Main Pipe Label field.

- Default Reporting Label Format Section

A pipe may be labelled with labels in various formats. One of these labels may be set as the default label, i.e. the label that will be used to identify the pipe in the database. If required, such labels may be highlighted on drawings by having them displayed in a different colour.

If this is required, check the Default Reporting Label Format checkbox.

To select the colour, select the Browse button adjacent to the Default Reporting Label Colour field, and select the colour from the Colour dialog (see above). The number code of the selected colour is then displayed in the field.

- Source and Destination Formats Section

A different display format from the normal display format (see below) may be used for pipe source and destination labels on a drawing, where the sources and/or destinations are different pipes. This section is used to switch on this facility and to define the required formats.

Check the Source Label Format and/or Destination Label Format checkboxes as required to switch on this facility for source/and or destination formats.

The buttons next to the Select Source Label Format and Select Destination Label Format are used to open the Tag Format Editor field in which the required format may defined.

12.12:77© 2011 AVEVA Solutions Ltd

Page 96: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

See the Display Label Format section below for details.

- Pipe Label Format Section

This section contains the following settings: • When using the properties dialog for pipe labelling, it is possible to toggle between

standard and single-field pipe labelling. The Fixed Pipe Label Format checkbox determines which the default setting is. If fixed (i.e. standard) pipe labelling is on, the whole of a pipe label must be placed on the drawing. If switched off, the option is available to place individual fields of the pipe label on the drawing.

• The Pipe Label Format fields are used to select the fields included in pipe labels, and the order in which they are displayed. Pipe labels may consist of up to fifteen fields and must include Size, Number and Specification (unless the 'Populate Spec in Database' checkbox is set) as a minimum.

12.12:78© 2011 AVEVA Solutions Ltd

Page 97: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Browse button adjacent to the field is used to select the format. On selection of the button, the Pipe Label Format dialog box is displayed:

The Pipe Label Format can be selected by using the drop down lists. A field cannot be selected twice.

Following selection, press OK. The selected Pipe Label Format will then be shown in the Pipe Label Format field as a set of values separated by commas, e.g. 1,3,5,6,10. The numbers represent label fields are follows:

1. Size

2. Fluid/Service

3. Number

4. Area

5. Specification

6. Insulation (Table)

7. Insulation (Index)

8. Insulation (Condition)

9. Paint Code

10. Tracing (No of Tracers)

11. Tracing (Size)

12. Tracing (Type)

13. Project1 (Project definable)

14. Project2 (Project definable)

12.12:79© 2011 AVEVA Solutions Ltd

Page 98: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

15. Project3 (Project definable)

- Display Label Format Section

This section contains the following settings: • The Display Label Format fields are used to select the types of data displayed in pipe

labels, and the order in which they are displayed. Fields may appear in a different order from those of the "actual" pipe label, and fields that are in the "actual" pipe label may be left out, though additional fields may not be included.

At least one display label format must be set up.

Multiple display label formats may set up, one of which will be set as the default. When labelling pipes, the label will default to this format, but another format may be selected if required.

The Browse button adjacent to the field is used to select the format. On selection of the button, the Select a Tag Format dialog is displayed:

The dialog lists the existing display formats.

To set a format as the default, select if from the list and select the Set as Default button. The current default format is indicated by the word "True" in the IsDefault column.

To edit a format, select it and then select the Edit button. The Tag Format Editor dialog is then displayed. Edit the format as described below.

To delete a format, select it and then select the Delete button.

12.12:80© 2011 AVEVA Solutions Ltd

Page 99: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To create a new format, select the New button. The Tag Format Editor dialog is then displayed.

The Tag Format field cannot be edited. It displays the current display label format configuration (i.e. the selected fields and delimiters).

Enter a description of the format in the Description field. If required, enter any additional information in the Remarks field.

The format is selected by using the drop down lists below these fields. A field cannot be selected twice.

Unlike the "actual" pipe label format, which uses the delimiter entered in the Delimiter field (see below) for every part of the label, the display format may have different delimiters displayed after each label component. Enter a delimiter for each label field used, or leave blank if no delimiter is required.

When the new display label format has been set up, select the Save button. The new format is then added to the list in the Select a Tag Format dialog. If required, set it as the default display label format as described above.

Press OK. The default display label format will then be shown in the Pipe Label Format field, e.g. 1,-,2,-,3,/,4,-,5,. Refer to the previous section (above) for the meanings of these numbers.

• The Delimiter field defines the delimiter separating the Pipe Label Format fields. The use of a '|' character is restricted as this is the delimiter used in the transfer files to VPE Workbench.

• The Unique Validation field is used to specify which combination of fields in pipe labels are to be checked for uniqueness.

12.12:81© 2011 AVEVA Solutions Ltd

Page 100: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Browse button adjacent to the field is used to select the values. On selection of the button, the Unique Validation dialog box is displayed:

The Unique Validation fields can be selected by using the drop down lists. Following selection, press OK, and the selected Unique Validation values will be shown in the Unique Validation field. e.g. 2, 9, 11.

• The Trim Label Prefix field is used to specify the text prefix to the trim identifier in a trim label. Whenever a trim label is created on a vessel, this word appears in front of the main label. If no prefix is required, change the setting to NONE.

• If a delimiter is required after an area code, the Delimiter After Area Field checkbox must be checked if display label format is not being used.

• If a delimiter is not required after an area code, the program needs to know how many characters are allowed for the Area field. Complete the Number of Characters fields with this value.

Note: Changes to drawings resulting from changes to the Display Label Format settings are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded. See 8.2.3: Updating PipeTags.

- Project Definable Fields Section

The fields in the Project Definable Fields section specify the boilerplate text for the three project definable fields, which appear on the pipe labelling Properties dialog. These fields are not validated within AVEVA P&ID.

The values in these fields are exported, so the field titles should match those set-up for the Line Tag in VPE Workbench. The fields may be validated during the Issue to Engineering operation into VPE Workbench.

12.12:82© 2011 AVEVA Solutions Ltd

Page 101: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

If required, from the adjacent drop-down lists, select lists of values that entries in these fields must be chosen from. If this is not required, select the <NONE> value from the list (this is the default entry). Lists of values are set up on the List of Values Configuration Category of the Administration program.

- Split Format Section

It is possible to place some fields of a pipe label above the pipe and the remainder below the pipe. This is termed Split Pipe Labelling and is controlled by the three fields in the Split Format section.

The Split After Field field is used to indicate which field in the pipe format to split on. The number entered here determines how many fields to count from the left of the pipe label before the split occurs.

The Y offset above line and Y offset below line fields are used to specify the positions of the two parts of the label as follows:

• If a pipe label symbol (see below) is not placed with a split label, the Y offset above line value is not used. The first part of the label is placed at the position specified by the user.

• If a pipe label symbol is placed with a split label, the first part of the label is offset by the amount specified in the Y offset above line field from the insertion point of the pipe label symbol, plus the offset specified in the Symbol X Offset and Symbol Y fields in the Pipe Label Symbols section (see below). It is recommended that 0 is entered in this field.

• Whether or not a pipe label symbol is placed, the second part of the label is then offset from the first part of the label by the amount specified in the Y offset below line field.

Note: The Y offset above line setting will be overridden by the Offset Distance setting (see below) if the Fix pipe label position checkbox is checked.#

- Define Split labels and offset for symbol Section

If split label formatting (see above) is to be used and a pipe labels symbol (see above) is to be used, up to four label fields may be placed before the split in the selected label symbol. This section is used to select which fields will be placed in the symbol and their to define their positions in the symbol.

Select the required fields from the list of values in the Label Type field. Select <NONE> from the list where no field is required. Select the position of each field relative to the insertion point of the label symbol in the Offset X and Offset Y fields.

- Display Instrument Labels at Pipe Destination Section

This section contains the following settings: • In the Display Instrument Labels at Pipe Destination Section, if the Pipe Instrument

Labelling checkbox is checked, instrument labels will be used for a pipes source or destination.

• The Instruments Allowing Labelling field is used to enter the list of instrument types which will be used as valid pipe sources or destinations. Enter a list of item types, for example: IRA,IR3,IR4,IRV,IBD.

12.12:83© 2011 AVEVA Solutions Ltd

Page 102: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Pipe Label Symbols Section

This section contains the following settings: • If the Pipe Label Symbol checkbox is checked, a symbol will be placed with fixed pipe

labels. For example, a box may be placed around the labels. • The Symbol Name field is used to select the name of the symbol that will be placed

with the pipe labels. • The Symbol X Offset and Symbol Y fields control the offset of the labels in relation to

the point selected when placing pipe symbols. Note that for split labels, the label insertion point may be further adjusted by the entry in the Y offset above line field (see above).

- Fix Single Pipe Label from owner segment

If the Fix pipe label position checkbox is checked, pipe labels subsequently placed will automatically be placed a fixed distance from the pipe segments they are labelling. This does not change the positioning of labels placed before the checkbox was checked.

Enter the distance that labels are to be placed from pipe segments in the Offset Distance field.

• Validation Sub-Set

This section is used to specify the permitted format of entries into selected pipe label fields.

12.12:84© 2011 AVEVA Solutions Ltd

Page 103: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

In the fields provided, enter the following characters as required:

For example, if AaN is entered for the Number field, when a user is completing this field in the Pipe labelling Properties dialog, the first character must be an uppercase letter, the second a lower case letter, and the third a number.

The Advanced Format Options dialog is available from the button adjacent to each field.

To test how the validation will work in practice, make an entry in the Test Data field of the Test tab, and press the Test button. A message will be displayed indicating whether or not the test data would be a valid entry.

To directly edit the regular expression that comprises the validation entry, select the Advanced tab. The expression is displayed in the Regular Expression field and may be amended as required. For help on editing Regular Expressions, click on the help link displayed on this tab.

Code Description

A Upper Case Alpha Character [A-Z]

a Lower Case Alpha Character [a-z]

M Mixed Case Alpha Character [A-Z, a-z]

F Upper Case Free Character [A-Z, 0-9, white space]

f Lower Case Free Character [a-z, 0-9, white space]

X Mixed Case Free Character [A-Z, a-z, 0-9, white space]

N Numeric Character [0-9]

12.12:85© 2011 AVEVA Solutions Ltd

Page 104: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Automatic Tag Format Sub-SetIf pipes are to be tagged automatically, the format of pipe tags is defined using this sub-category.

If automatic tagging is to be used, check the Apply Project based Auto Tagging checkbox.

Place the cursor in the Tag Expression field, and select the Insert Counter button. The counter is added like so: [Counter].

Enter the number that the counter is to be incremented by in the Increment By field. Select the length of the counter number from the list in the Format field.

To clear the Tag Expression field, select the Clear button.

The counter may be reset to 0 for the project by selecting the Reset Counter button.

12.12:86© 2011 AVEVA Solutions Ltd

Page 105: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.13 Signal Styles Configuration Category

The Signal Styles application pane is used to configure signal styles for the project.

The first section of the application pane consists of a Default Signal Line Style field, which has a drop down list for selecting the default Signal Style.

• Creating New Signal Line Styles

If a signal line style is to be created, select the button. The following dialog box is then displayed:

Enter a unique value for the signal line style and press the OK button.

12.12:87© 2011 AVEVA Solutions Ltd

Page 106: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The dialog box will be closed and the entered new value will be displayed in the Signal Name column.

Once a signal line style has been added its layer and colour must be configured in the Item Types - Signal Sub-Set.

For the complete procedure for creating new signal line styles, see 2.7: Defining a New Signal Line Type.

• Editing Signal Styles When editing an existing signal line style, you can select a P&ID Type from a list of values, select the base AutoCAD line style from the Line Type field, and add or change the description in the Type field.

When defining a new signal style, a new P&ID type has to be created. This is achieved by assigning a unique type value of three characters, starting with 'S'. AVEVA P&ID will then recognize this as a new signal line type. Then select the base AutoCAD line style from the Line Type field, and add or change the description in the Type field.

To edit a signal style name, select the button and enter the new value in the dialog that is then displayed.

12.12:88© 2011 AVEVA Solutions Ltd

Page 107: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.14 Tracing Configuration Category

The Tracing application pane is used to configure tracing styles for the project.

The application pane is divided into two sections.

The first section contains the following settings: • In the Offset field, enter the distance between pipe lines and the tracing lines on project

P&IDs. Must be at least 1mm or 0.075". • From the Default field select the default graphical tracing style from the list of available

styles (e.g. ELEC). • From the Select Trace File field, select the tracing file that you wish to edit. The

contents of the selected file are then displayed in the grid section. There are four tracing files.

• The Graphical Tracing Style file controls the appearance of the different tracing styles on project P&IDs, while the others are lists of values used when tracing is defined in pipe label fields.

Two default graphical styles, ELEC and STEAM, are supplied with the product. These styles may be edited, and new styles added as required.

The other three files contain the lists of values available from the fields on the Pipe Properties dialog used for defining the tracing properties of pipes: Code, Size and Type.

The second section of the application pane consists of a grid. This grid is used to edit the selected trace file.

When defining a new graphical tracing style, or editing an existing one, you can select the base AutoCAD line style from the Line Type field, and add or change a descriptive name in the Trace Type field.

When editing one of the other files, you can add, change or delete values as required.

12.12:89© 2011 AVEVA Solutions Ltd

Page 108: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Creating a new Tracing Style or Value

If a tracing style or value is to be created, select the button. The following dialog box is then displayed:

Enter a unique name for the tracing style, or a new value as appropriate, and press the OK button.

The dialog box will be closed and the entered new entry will be displayed in the grid.

To edit a tracing style name, select the button and enter the new value in the dialog that is then displayed.

12.12:90© 2011 AVEVA Solutions Ltd

Page 109: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.15 Instruments Configuration Category

The Instruments Configuration Category is divided into five sub-categories: • Settings Sub-Set• Labels Sub-Set • Patterns Sub-Set • Validation Sub-Set • Automatic Tag Format Sub-Set

12.12:91© 2011 AVEVA Solutions Ltd

Page 110: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Settings Sub-Set

This application pane is used to set up the configuration properties of instruments.

12.12:92© 2011 AVEVA Solutions Ltd

Page 111: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The application pane is divided into seven sections.

- Number of TAG fields Section

If four tag fields are to be used for project instruments (Prefix, Type, Number, Suffix), select the 4 Tag Fields option.

If six tag fields are to be used for project instruments (Block, Function, Prefix, Type, Number, Suffix), select the 6 Tag Fields option.

Note: Two extra tag fields (block and Function) were introduced with AVEVA VPE P&ID 7.2 SP1. Before a project can use these two new fields, the project database schema must be updated by selecting the Upgrade Database Schema - Upgrade button on the VPE Workbench Configuration Category.

- Values to Remember from Last Instrument Edit Section

This section contains a number of checkboxes - Block, Function, Prefix, Type, Number, Suffix, Descriptor, Pattern Reference, Alarm 1, Alarm 2, Alarm 3, Alarm 4, Size and Specification.

Note that the Block and Function checkboxes are only active if the 6 Tag Fields option in the Number of Tag fields section is selected.

A project can be configured so that a value entered in a field in a Properties dialog is "remembered" by the same field when that Properties dialog is accessed again when labelling another, previously unlabelled, item of that type.

If, for example, the functionality is switched on for the instrument Prefix field, and an instrument is labelled with a value of "20". The next time an instrument is labelled for the first time, when the Properties dialog for this item is opened, the Prefix field will automatically be completed with the value "20". This can be replaced by another value if required. This new value will then be the "remembered" value for the instrument Prefix field.

This functionality is switched on and off for individual Properties dialog fields by checking and unchecking the checkboxes in this section.

- Instrument Panel Dialog Labels Section

This section contains four fields, which are used to specify the boilerplate text to replace the defaults of Prefix, Tag, Number and Suffix in the Instrument Panel Reference Properties dialog and other dialogs.

- Instrument Dialog Labels and List of Values Section

This section contains four or six active fields, depending on the setting in the Number of Tag fields section.

They are used to specify the boilerplate text to replace the defaults of Block, Function, Prefix, Tag, Number and Suffix in the Label Instrument Properties dialog and other dialogs.

12.12:93© 2011 AVEVA Solutions Ltd

Page 112: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The first two fields are not active if the 4 Tag Fields option in the Number of Tag fields section is selected, i.e.:

In the Delimiter After Field 1, 2, 3, 4 and 5 fields, enter the delimiters used to separate the fields.

Note that these delimiters are not displayed on P&IDs or in the Engineering Explorer. They are used to ensure tag format consistency when exporting to PDMS via the ISO15926/P&ID Manager interface.

If required, from the drop-down lists next to each field, select the list of values against which entries in a tag field are to be validated: Area Code, Block Code, Function Code or Instrument Type.

• Area Code• Block Code• Equipment Type• Function Code• Imperial Size• Instrument Type Letter• Insulation Table• Insulation Condition• Insulation Index• Metric Size• Paint Code• Service/Fluid Code• Specification Code• Valve Code• Valve Closure

A list cannot be selected more than once. Lists of values are set up on the List of Values Configuration Category of the Administration program.

Note: List of values validation takes priority over both pipe label inheritance and sheet attribute inheritance (see below).

- Inheritance Section

This section contains the following settings: • If instrument properties are to be inherited from owner pipes the Inherit Item Labels

from Owner Pipes checkbox must be checked. Note the Inherit Item Labels from Owner Pipes checkbox on the Miscellaneous - Settings Sub-Set must also be checked, as this activates the pipe label inheritance feature for the project as a whole.

12.12:94© 2011 AVEVA Solutions Ltd

Page 113: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Note: If an instrument label field is set to be validated against a list of values its Fields from Pipes field will not be accessible. List of values validation takes priority over pipe label inheritance. However, pipe label inheritance takes priority over sheet attribute inheritance (see below).

• If item labels are to be inherited from owner pipes, the fields to be inherited from for each label are specified in the Instrument Prefix, Type, Number and Suffix fields, plus the Block and Function fields if the 6 Tag Fields option in the Number of Tag fields section is selected.

• The Browse button adjacent to these fields is used to select the fields to be inherited from. On selection of the button, the following dialog box is displayed:

The fields required are selected using the drop down lists. Following selection, press OK. The selected fields will then be displayed in the Instrument Prefix, Type, Number and Suffix fields, plus the Block and Function fields if the 6 Tag Fields option in the Number of Tag fields section is selected.

• The values of instrument labels may be inherited from the sheet attributes entered on the Advanced Drawing Properties sheet. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design area. The inheritance facility enables all items to inherit these common values. The labels of items that do not share these common values may subsequently be edited manually using their properties sheets.

The Fields from Sheet Attribute fields are used to select which instrument label fields are to inherit values from which sheet attributes. As required, select for each instrument label field the sheet attribute field from which values are to be inherited.

Note: If an instrument label field is already set to inherit from the owning pipe, or is set to be validated against a list of values (see above), its Fields from Sheet Attribute field will not be accessible. Both list of values validation and Pipe label inheritance take priority over sheet attribute inheritance.

12.12:95© 2011 AVEVA Solutions Ltd

Page 114: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

• Instrument label fields that inherit values from sheet attributes can be hidden, i.e. though they are part of instrument labels and will be included in any exports of P&ID data, they are not displayed on P&IDs. To hide an inherited instrument label field, check the checkbox next to the field in question. The Type and Number fields cannot be hidden.

Note: Changing these settings will not change the appearance existing item labels. Only the appearance of labels subsequently added to a drawing will be affected.

- Label Validation Across P&IDs Section

The project may be set to check that all instrument labels in all P&IDs in a project are unique.

• Select the Prevent button if users are to be prevented from entering project duplicate instrument labels. If this is attempted, an error message is displayed and the duplicate label may not be placed on the P&ID.

• Select the Warn button if users are to be warned if they enter project duplicate instrument labels. The entry of duplicate labels is permitted in this case, but an error message will be displayed on the P&ID, and will accompany the instrument label data when transferred to VPE Workbench.

• If no uniqueness validation of instrument labels across P&IDs is required, select Ignore button. Duplicate instrument labels may be entered in different P&IDs in this case. Duplicate instrument labels are still not permitted in the same P&ID.

Note that if the Prevent or Warn options are set, a connection to the VPE Workbenchdatabase must be established before labels can be edited. This is because in order to check the uniqueness of labels across a project, AVEVA P&ID refers to data that is extracted from the VPE Workbench database.

- Instrument Loop Tag Section

This section is used to define which fields are used to identify instrument loops, and which of these fields are inherited by instruments in loops.

This section contains four or six pairs of checkboxes, depending on the setting in the Number of Tag fields section.

• As required, check the Block, Function, Prefix and/or Suffix checkboxes to define which fields are to be used to identify instrument loops.

• The Type and Number checkboxes are checked automatically and cannot be unchecked. Type and Number are the minimum fields required to identify instrument loops.

• If instruments within a loop are to inherit values from the loop they are in, check the appropriate Inherit Field to Instrument checkbox. For example, if instruments in a loop are to inherit the function of the loop, check the Inherit Function to Instrument checkbox.

• If an Inherit Field to Instrument checkbox is checked, the adjacent loop field checkbox is checked automatically. For example if the Inherit Function to Instrument checkbox is checked, the Function checkbox is checked automatically.

• The Inherit Type to Instrument checkbox is unchecked automatically and cannot be changed. The instrument type cannot be inherited.

• The Inherit Number to Instrument checkbox is checked automatically and cannot be changed. The instrument type is always inherited.

12.12:96© 2011 AVEVA Solutions Ltd

Page 115: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• The Display Label Format Fields field is used to select the types of data displayed in instrument loop labels, and the order in which they are displayed. Fields may appear in a different order from those of the "actual" label, and fields that are in the "actual" label may be left out, though additional fields may not be included.

The Browse button adjacent to the field is used to select the format. On selection of the button, the Display Label Format dialog box is displayed:

Use the lists of values to select which fields are to be displayed, and the order that they are to be displayed in. For example, if Type is to appear first, select Type from the list of values in the Field 1 field.

A field will not be available for selection unless its checkbox has been checked to specify that it will be part of instrument loop tags, as described above. The number of active fields in the dialog depends on the number of checkboxes checked.

As required, enter a delimiter character in the field adjacent to each field selection list. For example, if the Type part of an instrument loop display label is to be separated from the next field in the label by a “-”, enter that symbol in the field next to the field in which Type is selected.

Following selection, press OK. The selected Display Label Format will then be shown in the Display Label Format Fields field, e.g. 1,-,2.

12.12:97© 2011 AVEVA Solutions Ltd

Page 116: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Labels Sub-Set

The fields in this application pane are used to set up the label configuration properties of instruments.

12.12:98© 2011 AVEVA Solutions Ltd

Page 117: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The application pane is divided into six sections:

- Label Options Section

This section contains the following settings: • The setting of the Loop Numbers from VPE Workbench checkbox determines whether

the instrument loop is imported from VPE Workbench or not. If this checkbox is checked, a temporary loop number is assigned to each instrument when data is exported to VPE Workbench and the loop numbers are then edited in VPE Workbenchand exported back to P&ID. When the P&ID is subsequently opened the loop numbers are revised accordingly. If this checkbox is checked the loop numbers are read only in P&ID.

• If instrument prefixes are required for the project, ensure that the Prefix Label Required checkbox is checked.

• If instrument labels are to be rotated when the symbol they are associated with is rotated, ensure that the Rotate Labels with Symbol checkbox is checked.

- Label Balloon Section

This section contains the following settings: • In the Label Balloon Symbol field, select the symbol name of the Instrument Label

Balloon symbol from the drop down list. • If all link lines between instruments and their balloons are to be switched off, then

ensure that the Label Balloon Link Lines Off checkbox is checked. This setting will not update existing instruments when the drawing is reloaded.

- Instrument Label Position Section

The fields in this section govern the positions of the different elements that make up an instrument label, relative to the insert point of the labelled instrument. In the fields provided, enter the X and Y coordinates for the instrument labels components.

The number of fields in which positions can be entered depends on the option selected in the Number of Tag fields section of the Settings pane. If the 4 Tag fields option is selected, the first two fields (Block and Function) will not be active.

If different label positions are needed for different types of instrument balloons, the default positioning can be overridden by selecting the Instrument Label Positional data option in the List of Values Configuration Category.

- Unique Tags Section

The Unique Validation field is used to specify which combination of fields in instrument labels are to be checked for uniqueness.

12.12:99© 2011 AVEVA Solutions Ltd

Page 118: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Browse button adjacent to the field is used to select the values. On selection of the button, the Select Unique Identifier(s) dialog box is displayed:

The fields can be selected by using the drop down lists. A field cannot be selected twice.

Following selection, press OK, and the numbers of the selected Unique Validation fields will be shown in the Unique Validation field. e.g. 1, 2, 3, 4, 5, 6.

The numbers represent label fields are follows:

1. Block

2. Function

3. Prefix

4. Tag

5. Number

6. Suffix

For example, if PREFIX, SUFFIX, NUMBER, TYPE was selected, the field would display: 3,6,5,4.

Note that if the 4 Tag fields option in the Number of Tag fields section of the Settings pane is selected, the first two lists will not be active.

Note that, although <NONE> can be selected from the drop down lists, all fields must be selected. If <NONE> is selected for any field, the format will reset to the default format of 1,2,3,4.

- Instrument Panel Label Position Section

The fields in this section govern the positions of the different elements that make up a panel label, relative to the insert point of the instrument panel reference symbols. In the fields

12.12:100© 2011 AVEVA Solutions Ltd

Page 119: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

provided, enter the X and Y coordinates for the Prefix, Letters, Number and Suffix parts of the instrument panel labels.

Panel reference label positioning does not automatically update on reload of the drawing if these settings have been changed.

- I/O Label Position Section

This section contains the following settings: • If I/O labels are to be placed on the Non-plot layer, ensure that the Labels on Non-Plot

Layer checkbox is checked. • I/O labels must be automatically positioned in the same place for each I/O symbol and

the X, Y offsets in the Offset from Symbol Origin fields control the automatic positioning of the I/O Address, Card Type, Signal/Area Code and Remarks.

• The four components of I/O Symbol labels may be individually rotated as they are brought in from VPE Workbench. Check the appropriate Rotate with Symbol checkboxes to activate the rotation. Ensure the checkboxes are unchecked to have the labels placed at zero degrees to the symbol angle.

• Patterns Sub-Set

The Pattern application pane is used to edit the definitions of project instrument patterns.

The application pane consists of two sections. The first section of the application pane is used to add, amend and delete pattern definitions.

12.12:101© 2011 AVEVA Solutions Ltd

Page 120: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Existing Patterns Section

The first section contains a list of existing patterns and three tools for managing patterns - Add Pattern, Delete Pattern and Rename Pattern.

- Adding a New Pattern

If a new pattern is to be created, select the Add Pattern…. hyperlink. The following dialog box is then displayed:

Enter a unique value for the pattern name and press the OK button

The dialog box will be closed and the new value is displayed in the Existing Patterns list box.

- Deleting a Pattern

If a pattern is to be deleted, select the Deleted Pattern…. hyperlink. The following dialog box is then displayed:

To proceed with the deletion select Yes. If the value is not to be deleted select No.

12.12:102© 2011 AVEVA Solutions Ltd

Page 121: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

If Yes is selected the dialog box will be closed and the pattern deleted from the Existing Patterns list box. All associated pattern property data is deleted.

- Renaming a Pattern

If a pattern is to be renamed, select the Rename Pattern…. hyperlink. The following dialog box is then displayed:

Enter a unique value for the pattern name and press the OK button

The dialog box will be closed and the amended name is displayed in the Existing Patterns list box.

- Patterns Components Section

The second section contains a grid, which is used to manage the components of a pattern.

See below for guidance on entering pattern component data.

• Entering Instrument Pattern Labels A pattern definition must consist of two types of items, a single substitute instrument (which is the item shown on the drawing), and the component instruments that it represents.

The substitute item can appear on any row; it does not have to be positioned first within the pattern listing.

Create a new row is created by selecting the button. The following dialog box is then displayed:

Enter the sequence number of the new row. The new row then is created at the bottom of the grid.

12.12:103© 2011 AVEVA Solutions Ltd

Page 122: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Pattern labels details are entered in the following fields:• Field 1: Sequence No • Field 2: Tag Label• Field 3: Suffix Label• Field 4: Symbol Name• Field 5: P&ID Substitute Item• Field 6: Instrument Alarms• Field 7: Instrument Desc• Field 8: Process Links• Field 9: Signal Lines• Field 10: No of Signal Line Types

- Field 1: Sequence No

Normally the item handle forms the unique identifier for an instrument exported to VPE Workbench. However, component pattern items do not posses such a handle. To overcome this lack, the handle of the substitute item is used together with an asterisk and the sequence number of the component item, e.g., AB*1, where AB is the substitute instrument handle, and 1 is the sequence number of the component instrument.

If there are no sequence numbers in the file, an error will occur on output.

If pattern instrument data has been loaded into VPE Workbench and the pattern is then changed on the P&ID, the existing sequence numbers should be maintained. For example, if the sequence was 1, 2, 3, and 2 was removed - the new sequence should be 1, 3, not 1, 2. This is to avoid inconsistencies which would occur if the pattern was reloaded into VPE Workbench.

Sequence numbers cannot be edited in the grid. The sequence number row must be deleted and re-entered with a new name.

- Field 2: Tag Label • Substitute Instrument: It is possible to label the substitute instrument with a

concatenated label, e.g., FEIT to indicate that it consists of an FE (the substitute item), an FI and an FT. However, the substitute item must appear in the IPT file with its valid name, i.e., FE.

12.12:104© 2011 AVEVA Solutions Ltd

Page 123: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Component Instruments: The tag part of the instrument label must be entered here for component items, e.g., FI, FE, FT.

- Field 3: Suffix Label • Substitute Instrument: If the substitute instrument has a suffix in its label, enter it here. • Component Instruments: If two or more pattern items are to be labelled identically

when the records are created on export, make sure that the suffices are entered in this column to prevent exact duplicates occurring.

- Field 4: Symbol Name• Substitute Instrument: This field has its data inherited from the P&ID, and must be left

blank. • Component Instruments: Enter the symbol names here for component items. Symbol

names can be identified using the Symbols Configuration Category of the AVEVA P&IDProject Administration program or from the item Properties dialogs.

- Field 5: P&ID Substitute Item

A pattern can consist of any number of component items, but only one inline substitute item is permitted.

The substitute item is denoted by an asterisk, *. If an attempt is made to export with two or more asterisks in any one pattern listing, an error message will be received.

The substitute item can appear on any row; it does not have to be positioned first within the pattern listing.

- Field 6: Instrument Alarms • Substitute Instrument: This field has its data inherited from the P&ID, and must be left

blank. • Component Instruments: Enter any alarms here separating them with commas, e.g., H,

HH. All other restrictions such as maximum of 4 alarms still apply.

- Field 7: Instrument Desc• Substitute Instrument: This field has its data inherited from the P&ID, and must be left

blank. • Component Instruments: The description is used within VPE Workbench. When

assigning VPE Workbench item types to incoming instruments from AVEVA P&ID, for example, a description of Vortex, Magnetic FLOW, Coriolis, or Turbine could be used to specifically differentiate between different types of FLOW transmitters. A more restricted choice of item types will be available than if the descriptor for the instrument were left blank.

- Field 8: Process Links• Substitute Instrument: The substitute item will either be inline or process connected.

Place an asterisk in this column if the substitute item is process connected. Leave blank if the instrument is inline.

• Component Instruments: Put an asterisk in this column if the pattern item is to appear as process connected in the export file.

Note: If component instruments are both process and signal connected, the process connection takes precedence.

12.12:105© 2011 AVEVA Solutions Ltd

Page 124: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Field 9: Signal Lines • Substitute Instrument: This field has its data inherited from the P&ID, and must be left

blank. • Component Instruments: Enter the number of signal lines here if the instrument is to be

signal connected, i.e., would have been attached to one or more signal lines if actually drawn on the P&ID.

Note: If instruments are BOTH process and signal connected, the process connection takes precedence.

- Field 10: No of Signal Line Types• Substitute Instrument: This field has its data inherited from the P&ID, and must be left

blank. • Component Instruments: Enter the number of signal line types which are to be

connected to the component instrument. On output the signal line types are checked for validity against the signal line validation file.

• Validation Sub-Set

This pane is used to specify the permitted format of entries into selected instrument and panel reference label fields.

Note that if the 4 Tag fields option in the Number of Tag fields section of the Settings pane is selected, the first two fields in the Instrument Label Field Validation section (Block and Function) will not be active.

12.12:106© 2011 AVEVA Solutions Ltd

Page 125: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

In the fields provided, enter the following characters as required:

For example, if AaN is entered for the Prefix Field field, when a user is completing this field in the Instruments labelling Properties dialog, the first character must be an uppercase letter, the second a lower case letter, and the third a number.

The Advanced Format Options dialog is available from the button adjacent to each field.

To test how the validation will work in practice, make an entry in the Test Data field of the Test tab, and press the Test button. A message will be displayed indicating whether or not the test data would be a valid entry.

To directly edit the regular expression that comprises the validation entry, select the Advanced tab. The expression is displayed in the Regular Expression field and may be amended as required. For help on editing Regular Expressions, click on the help link displayed on this tab.

Code Description

A Upper Case Alpha Character [A-Z]

a Lower Case Alpha Character [a-z]

M Mixed Case Alpha Character [A-Z, a-z]

F Upper Case Free Character [A-Z, 0-9, white space]

f Lower Case Free Character [a-z, 0-9, white space]

X Mixed Case Free Character [A-Z, a-z, 0-9, white space]

N Numeric Character [0-9]

12.12:107© 2011 AVEVA Solutions Ltd

Page 126: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Automatic Tag Format Sub-SetIf Instruments are to be tagged automatically, the format of instruments tags is defined using this sub-category.

If automatic tagging is to be used, check the Apply Project based Auto Tagging checkbox.

Place the cursor in the Tag Expression field, and select the Insert Counter button. The counter is added like so: [Counter].

Enter the number that the counter is to be incremented by in the Increment By field. Select the length of the counter number from the list in the Format field.

To clear the Tag Expression field, select the Clear button.

The counter may be reset to 0 for the project by selecting the Reset Counter button.

12.12:108© 2011 AVEVA Solutions Ltd

Page 127: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.16 Equipment Configuration Category

The Equipment Configuration Category is divided into four sub-categories: • Settings Sub-Set • Labels Sub-Set • Validation Sub-Set • Automatic Tag Format Sub-Set

12.12:109© 2011 AVEVA Solutions Ltd

Page 128: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Settings Sub-Set

12.12:110© 2011 AVEVA Solutions Ltd

Page 129: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The fields in this application pane are used to set up the configuration properties of equipment.

The application pane is divided into eight sections.

- Number of TAG fields Section

If four tag fields are to be used for project equipment (Prefix, Type, Number, Suffix), select the 4 Tag Fields option.

If six tag fields are to be used for project equipment (Block, Function, Prefix, Type, Number, Suffix), select the 6 Tag Fields option.

Note: Two extra tag fields (block and Function) were introduced with AVEVA VPE P&ID 7.2 SP1. Before a project can use these two new fields, the project database schema must be updated by selecting the Upgrade Database Schema - Upgrade button on the VPE Workbench Configuration Category.

- Equipment Classification Section

If, when equipment is exported (e.g. to AVEVA P&ID Manager), the descriptions of equipment in the equipment type validation files are to be used instead of the descriptions associated with the equipment symbol types, check the Use Equipment Type Specification checkbox

- Equipment Data from VPE Workbench Section

This section contains the following settings: • The item type of EDL enables a chosen symbol to be placed on a P&ID and associated

with a piece of equipment. When an import of equipment data is carried out from VPE Workbench, an EDL file is created. When the P&ID is loaded and AVEVA P&IDinitialised with the Import Equipment Data checkbox checked, the exported data from the file will attach itself to the correct EDL symbol and appear on the P&ID.

• The first piece of data is placed on the insert point of the symbol. The Column X Offsets and Row Y Offsets fields control the offsetting of successive items of equipment information relative to the EDL symbol. The numbers represent relative distances between the pieces of information and are separated by the "pipe" character: |. It is possible to arrange information in a table format using the X and Y offset distances.

• The Browse button adjacent to the Column X Offsets field is used to select the value for thus field. On selection of the button, the Equipment X Offsets dialog box is displayed:

Following selection press OK. The selected Equipment X Offsets will then be displayed in the Equipment X Offsets field as a set of values separated by a delimiter.

12.12:111© 2011 AVEVA Solutions Ltd

Page 130: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Dialog Box Field Labels and List of Values Section

This section contains four or six active fields, depending on the setting in the Number of Tag fields section.

They are used to specify the boilerplate text to replace the defaults of Block, Function, Prefix, Tag, Number and Suffix in Equipment properties sheets.

The first two fields are only active if the 6 Tag Fields option in the Number of Tag fields section is selected, i.e.:

If required, from the drop-down lists next to each field, select the list of values against which entries in a tag field are to be validated: Area Code, Block Code, Function Code or Equipment Type.

• Area Code• Block Code• Equipment Type• Function Code• Imperial Size• Instrument Type Letter• Insulation Table• Insulation Condition• Insulation Index• Metric Size• Paint Code• Service/Fluid Code• Specification Code• Valve Code• Valve Closure

A list cannot be selected more than once. List of values are set up on the List of Values Configuration Category of the Administration program.

- Values to Remember from Last Equipment Edit Section

This section contains a number of checkboxes - Block, Function, Prefix, Type, Number, Suffix, Size and Specification.

Note that the Block and Function checkboxes are only active if the 6 Tag Fields option in the Number of Tag fields section is selected.

12.12:112© 2011 AVEVA Solutions Ltd

Page 131: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

A project can be configured so that a value entered in a field in a Properties dialog is "remembered" by the same field when that Properties dialog is accessed again when labelling another, previously unlabelled, item of that type.

If, for example, the functionality is switched on for the equipment Prefix field, and an equipment item is labelled with a value of "20". The next time an equipment item is labelled for the first time, when the Properties dialog for this item is opened, the Prefix field will automatically be completed with the value "20". This can be replaced by another value if required. This new value will then be the "remembered" value for the equipment Prefix field.

This functionality is switched on and off for individual Properties dialog fields by checking and unchecking the checkboxes in this section.

- Values to Remember from Last In-Line Equipment Edit Section

The checkboxes in this section are used in the same way as those in the Values to Remember from Last Equipment Edit Section but for inline equipment Properties dialog fields.

- Label Validation Across P&IDs Section

The project may be set to check that all equipment labels in all P&IDs in a project are unique.

• Select the Prevent button if users are to be prevented from entering project duplicate equipment labels. If this is attempted, an error message is displayed and the duplicate label may not be placed on the P&ID.

• Select the Warn button if users are to be warned if they enter project duplicate equipment labels. The entry of duplicate labels is permitted in this case, but an error message will be displayed on the P&ID, and will accompany the equipment label data when transferred to VPE Workbench.

• If no uniqueness validation of equipment labels across P&IDs is required, select Ignore button. Duplicate equipment labels may be entered in different P&IDs in this case. Duplicate equipment labels are still not permitted in the same P&ID.

Note that if the Prevent or Warn options are set, a connection to the VPE Workbenchdatabase must be established before labels can be edited. This is because in order to check the uniqueness of labels across a project, AVEVA P&ID refers to data that is extracted from the VPE Workbench database.

- Equipment Inheritance Section

The values of equipment labels may be inherited from the sheet attributes entered on the Advanced Drawing Properties sheet. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design area. The inheritance facility enables all items to inherit these common values. The labels of items that do not share these common values may subsequently be edited manually using their properties sheets.

The Fields from Sheet Attribute fields are used to select which equipment label fields are to inherit values from which sheet attributes. As required, select for each equipment label field the sheet attribute field from which values are to be inherited.

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

Equipment label fields that inherit values from sheet attributes can be hidden, i.e. though they are part of equipment labels and will be included in any exports of P&ID data, they are not displayed on P&IDs. To hide an inherited equipment label field, check the checkbox next to the field in question. The Type and Number fields cannot be hidden.

12.12:113© 2011 AVEVA Solutions Ltd

Page 132: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Note: Changing these settings will not change the appearance existing item labels. Only the appearance of labels subsequently added to a drawing will be affected.

- In-line Equipment Inheritance Section

This section contains the following settings: • If item labels are to be inherited from owner pipes, the fields to be inherited from for

each label are specified in the Prefix, Type, Number and Suffix fields, plus the Block and Function fields if the 6 Tag Fields option in the Number of Tag fields section is selected.

• The Browse button adjacent to these fields is used to select the fields to be inherited from. On selection of the button, the following dialog box is displayed:

The fields required are selected using the drop down lists. Following selection, press OK. The selected fields will then be displayed in the Prefix, Type, Number and Suffix fields, plus the Block and Function fields if the 6 Tag Fields option in the Number of Tag fields section is selected.

• The values of inline equipment labels may be inherited from the sheet attributes entered on the Advanced Drawing Properties sheet. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design area. The inheritance facility enables all items to inherit these common values. The labels of items that do not share these common values may subsequently be edited manually using their properties sheets.

The Fields from Sheet Attribute fields are used to select which inline equipment label fields are to inherit values from which sheet attributes. As required, select for each inline equipment label field the sheet attribute field from which values are to be inherited.

12.12:114© 2011 AVEVA Solutions Ltd

Page 133: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Note that if an inline equipment label field is already set to inherit from the owning pipe (see above), this Fields from Sheet Attribute field will not be accessible. Pipe label inheritance takes priority over sheet attribute inheritance.

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

12.12:115© 2011 AVEVA Solutions Ltd

Page 134: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Labels Sub-Set

12.12:116© 2011 AVEVA Solutions Ltd

Page 135: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The fields in this application pane are used to set up the equipment label configuration format.

The application pane is divided into seven sections.

- Label Format Section

This section contains the following settings: • Delimiter After Field 1 to 5. These checkboxes control the type and the presence or

absence of a delimiter after the Block, Function, Prefix, Type and Number fields when a fixed equipment label format is being used. For example, if a delimiter is to be placed after the first field, check the Delimiter after Field 1 checkbox.

Depending on the set-up of the project options, delimiters will appear automatically when the equipment label is placed. Trailing delimiters will not occur if parts of the equipment label are not used.

- Equipment Label Position Section

This section contains the following settings: • The Use Fixed Equipment Label Format and Use Fixed In-Line Equipment Label

Format checkboxes are used to specify whether or not equipment and in-line equipment labels are to be placed as a single text string (fixed formatting), or if the individual components of such labels are to be placed at specified X and Y coordinates from the label insertion point. Uncheck the checkbox if label components are to be placed at specified X and Y coordinates.

• The Block, Function, Prefix, Type Letter, Number, and Suffix Position fields are used to set the X and Y coordinates of equipment and in-line equipment label components when fixed formatting is not in use. These fields are disabled if the Use Fixed Equipment Label Format checkbox is checked.

The number of fields in which positions can be entered depends on the option selected in the Number of Tag fields section of the Settings pane. If the 4 Tag fields option is selected, the first two fields (Block and Function) will not be active.

12.12:117© 2011 AVEVA Solutions Ltd

Page 136: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Equipment Label Format Section

The Equipment Label Format fields are used to specify the format of equipment labels, i.e. the order in which equipment label fields are displayed.

The Browse button adjacent to the field is used to select the format. On selection of the button, the Select Unique Identifiers dialog box is displayed:

The Equipment Label Format can be selected by using the drop down lists.

Following selection, press OK, and the numbers of the selected Unique Validation fields will be shown in the Unique Validation field. e.g. 1, 2, 3, 4, 5, 6.

The numbers represent label fields are follows:

1. Block

2. Function

3. Prefix

4. Tag

5. Number

6. Suffix

For example, if PREFIX, SUFFIX, NUMBER, TYPE was selected, the field would display: 3,6,5,4.

Note that if the 4 Tag fields option in the Number of Tag fields section of the Settings pane is selected, the first two lists will not be active.

Note that, although <NONE> can be selected from the drop down lists, all fields must be selected. If <NONE> is selected for any field, the format will reset to the default format of 1,2,3,4.

12.12:118© 2011 AVEVA Solutions Ltd

Page 137: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Note: Changes to drawings resulting from changes to the Equipment Label Format settings are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded. See 8.2.2: Updating Equipment Tags.

- Unique Tags Section

The Unique Validation field is used to specify which combination of fields in equipment labels are to be checked for uniqueness.

The Browse button adjacent to the field is used to select the values. On selection of the button, the Select Unique Identifier(s) dialog box is displayed:

The fields can be selected by using the drop down lists. A field cannot be selected twice.

Following selection, press OK, and the numbers of the selected Unique Validation fields will be shown in the Unique Validation field. e.g. 1, 2, 3, 4. Refer to the previous section (above) for the meanings of these numbers.

- Equipment Label Symbol Section

This section contains the following settings: • Equipment Label Symbol. If this checkbox is checked a symbol will be placed with

equipment labels. For example, a box may be placed around the labels. • Symbol Name. This field is used to select the name of the symbol that will be placed

with the equipment labels. • Symbol X Offset. The X offset to the equipment type letters label. • Symbol Y Offset. The Y offset to the equipment type letters label.

12.12:119© 2011 AVEVA Solutions Ltd

Page 138: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- In-Line Equipment Label Position Section

This section contains the following settings: • Use Fixed In-Line Equipment Label Format. This checkbox is used to specify whether

or not in-line SPP equipment labels are to be placed as a single line (fixed formatting), or if the individual components of such labels are to be placed at specified X and Y coordinates from the label insertion point. Uncheck the checkbox if label components are to be placed at specified X and Y coordinates.

• Block, Function, Prefix, Type Letter, Number, and Suffix Position. The fields in this section are used to set the X and Y coordinates of in-line SPP equipment label components when fixed formatting is not in use. These fields are disabled if the Use Fixed In-Line Equipment Label Format checkbox is checked.

The number of fields in which positions can be entered depends on the option selected in the Number of Tag fields section of the Settings pane. If the 4 Tag fields option is selected, the first two fields (Block and Function) will not be active.

- In-Line Equipment Label Symbol Section

This section contains the following settings: • In-Line Equipment Label Symbol. If this checkbox is checked a symbol will be placed

with in-line equipment labels. For example, a box may be placed around the labels. • Symbol Name. This field is used top select the name of the symbol that will be placed

with the in-line equipment labels. • Symbol X Offset. The X offset to the in-line equipment type letters label. • Symbol Y Offset. The Y offset to the in-line equipment type letters label.

12.12:120© 2011 AVEVA Solutions Ltd

Page 139: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Validation Sub-Set

This pane is used to specify the permitted format of entries into selected equipment and in-line equipment label fields.

Note that if the 4 Tag fields option in the Number of Tag fields section of the Settings pane is selected, the first two fields in both sections (Block and Function) will not be active.

In the fields provided, enter the following characters as required:

For example, if AaN is entered for the Prefix Field field, when a user is completing this field in the Equipment labelling Properties dialog, the first character must be an uppercase letter, the second a lower case letter, and the third a number.

The Advanced Format Options dialog is available from the button adjacent to each field.

Code Description

A Upper Case Alpha Character [A-Z]

a Lower Case Alpha Character [a-z]

M Mixed Case Alpha Character [A-Z, a-z]

F Upper Case Free Character [A-Z, 0-9, white space]

f Lower Case Free Character [a-z, 0-9, white space]

X Mixed Case Free Character [A-Z, a-z, 0-9, white space]

N Numeric Character [0-9]

12.12:121© 2011 AVEVA Solutions Ltd

Page 140: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To test how the validation will work in practice, make an entry in the Test Data field of the Test tab, and press the Test button. A message will be displayed indicating whether or not the test data would be a valid entry.

To directly edit the regular expression that comprises the validation entry, select the Advanced tab. The expression is displayed in the Regular Expression field and may be amended as required. For help on editing Regular Expressions, click on the help link displayed on this tab.

12.12:122© 2011 AVEVA Solutions Ltd

Page 141: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Automatic Tag Format Sub-SetIf equipment is to be tagged automatically, the format of equipment tags is defined using this sub-category.

If automatic tagging is to be used, check the Apply Project based Auto Tagging checkbox.

Place the cursor in the Tag Expression field, and select the Insert Counter button. The counter is added like so: [Counter].

Enter the number that the counter is to be incremented by in the Increment By field. Select the length of the counter number from the list in the Format field.

To clear the Tag Expression field, select the Clear button.

The counter may be reset to 0 for the project by selecting the Reset Counter button.

12.12:123© 2011 AVEVA Solutions Ltd

Page 142: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.17 Valves Configuration Category

The Valves Configuration Category is divided into five sub-categories:• Settings Sub-Set• Labels Sub-Set • Validation Sub-Set • Automatic Tag Format Sub-Set• Patterns Sub-Set

12.12:124© 2011 AVEVA Solutions Ltd

Page 143: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Settings Sub-Set

The fields in this application pane are used to set up the configuration properties of valves.

12.12:125© 2011 AVEVA Solutions Ltd

Page 144: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The application pane is divided into five sections.

- Valve Settings Section

This section contains the following settings: • If the labels of valve tags are to automatically be placed in a fixed position when valves

are labelled, check the Valve Tag in Fixed Location checkbox. • If valve tag labels are to be automatically rotated to match the orientation of the valves

they are associated with, check the Rotate Valve Tag with Symbol checkbox. • If valve labels are to inherit data from owning pipes the Inherit Item Labels from Owner

Pipes checkbox must be checked. Note the Inherit Item Labels from Owner Pipes checkbox on Miscellaneous - Settings Configuration Category pane must also be checked, as this activates the pipe label inheritance feature for the project as a whole.

• The Valve Tag field is used to specify the pipe label fields to be inherited by the valve tag.

Note: If automatic valve tagging is to be used (see 6.10.25: Automatic Tagging), do not set up inheritance to the Tag field.

• The Browse button adjacent to the field is used to select the fields to be inherited from. On selection of the button, the following dialog box is displayed:

The fields required are selected using the drop down lists. Following selection, press OK. The selected field numbers will then be displayed in the Valve Tag field.

- Valve Tag Offset from Symbol Location Section

This section contains the following settings to enable valve tag labels to be placed in a fixed position. This is undertaken by completing the X and Y Valve Tag offset from symbol location fields with the appropriate position coordinates.

12.12:126© 2011 AVEVA Solutions Ltd

Page 145: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Use Valve code checkbox controls whether the valve Code field is present on the Valve Properties dialog.

- Values to Remember from Last Valve Edit Section

This section contains nine checkboxes - Tag, Size, Closure, Code, Specification, SPP Prefix, SPP Type, SPP Number and SPP Suffix.

A project can be configured so that a value entered in a field in a Properties dialog is "remembered" by the same field when that Properties dialog is accessed again when labelling another, previously unlabelled, item of that type.

If, for example, the functionality is switched on for the valve Tag field, and a valve is labelled with a value of "V-0001". The next time a valve is labelled for the first time, when the Properties dialog for this item is opened, the Tag field will automatically be completed with the value "V-0001". This can be replaced by another value if required. This new value will then be the "remembered" value for the valve Tag field.

This functionality is switched on and off for individual Properties dialog fields by checking and unchecking the checkboxes in this section.

- Label Validation Across P&IDs Section

The project may be set to check that all valve labels in all P&IDs in a project are unique. • Select the Prevent button if users are to be prevented from entering project duplicate

valve labels. If this is attempted, an error message is displayed and the duplicate label may not be placed on the P&ID.

• Select the Warn button if users are to be warned if they enter project duplicate valve labels. The entry of duplicate labels is permitted in this case, but an error message will be displayed on the P&ID, and will accompany the valve label data when transferred to VPE Workbench.

• If no uniqueness validation of valve labels across P&IDs is required, select Ignore button. Duplicate valve labels may be entered in different P&IDs in this case.

Separate sets of buttons are provided for normal valves and for valves which are special pipe items.

Note that if the Prevent or Warn options are set, a connection to the VPE Workbenchdatabase must be established before labels can be edited. This is because in order to check the uniqueness of labels across a project, AVEVA P&ID refers to data that is extracted from the VPE Workbench database.

- Inheritance Section

This section contains the following settings: • If item labels are to be inherited from owner pipes, the fields to be inherited from for

each label are specified in the Tag, Prefix, Type, Number and Suffix fields.

Note: If automatic valve tagging is to be used (see 6.10.25: Automatic Tagging), do not set up inheritance to the Tag field.

12.12:127© 2011 AVEVA Solutions Ltd

Page 146: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• The Browse button adjacent to these fields is used to select the fields to be inherited from. On selection of the button, the following dialog box is displayed:

The fields required are selected using the drop down lists. Following selection, press OK. The selected fields will then be displayed in the Tag, Prefix, Type, Number and Suffix fields.

• The values of valve labels may be inherited from the sheet attributes entered on the Advanced Drawing Properties sheet. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design area. The inheritance facility enables all items to inherit these common values. The labels of items that do not share these common values may subsequently be edited manually using their properties sheets.

The Fields from Sheet Attribute fields are used to select which valve label fields are to inherit values from which sheet attributes. As required, select for each valve label field the sheet attribute field from which values are to be inherited.

Note that if a valve label field is already set to inherit from the owning pipe (see above), this Fields from Sheet Attribute field will not be accessible. Pipe label inheritance takes priority over sheet attribute inheritance.

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

12.12:128© 2011 AVEVA Solutions Ltd

Page 147: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Labels Sub-Set

The fields in this application pane are used to set up the label properties of valves.

The application pane is divided into three sections:

- Valve Labels Section

This section contains the following settings: • If the valve code is to be automatically positioned on P&IDs, uncheck the Manual

Placement checkbox. • If port sizes for port valves are to be placed on the drawing by default, ensure that the

Place Port Sizes checkbox is checked.

- Code Offset from Symbol Origins Section

To specify the position in which automatic placement of the valve code takes place, enter coordinates in the Code Offset from Symbol Origins X and Y fields. These coordinates represent the X and Y distances from the insert point of the valve.

- Dialog Box Field Labels Section

This section contains four fields, which are used to specify the boilerplate text to replace the defaults of Prefix, Tag, Number and Suffix in the Valve Properties dialog.

12.12:129© 2011 AVEVA Solutions Ltd

Page 148: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

These fields are only completed if the valve is a Special Piping Item (SPP). The Miscellaneous - Validation Sub-Set is used to specify validation rules for entries into SPP properties fields of both valves and line fittings.

- Valve Label Symbol Section

This section contains the following settings: • Valve Label Symbol. If this checkbox is checked a symbol will be placed with

equipment labels. For example, a box may be placed around the labels. • Symbol Name. This field is used to select the name of the symbol that will be placed

with the valve labels. • Symbol X Offset. The X offset to the equipment type letters label. • Symbol Y Offset. The Y offset to the equipment type letters label.

• Validation Sub-Set

This section is used to specify the permitted format of entries into the Tag field of valve labels.

In the fields provided, enter the following characters as required:

For example, if AaN is entered, when a user is completing Tag field in the Valves labelling Properties dialog, the first character must be an uppercase letter, the second a lower case letter, and the third a number.

Code Description

A Upper Case Alpha Character [A-Z]

a Lower Case Alpha Character [a-z]

M Mixed Case Alpha Character [A-Z, a-z]

F Upper Case Free Character [A-Z, 0-9, white space]

f Lower Case Free Character [a-z, 0-9, white space]

X Mixed Case Free Character [A-Z, a-z, 0-9, white space]

N Numeric Character [0-9]

12.12:130© 2011 AVEVA Solutions Ltd

Page 149: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Advanced Format Options dialog is available from the button adjacent to the field.

To test how the validation will work in practice, make an entry in the Test Data field of the Test tab, and press the Test button. A message will be displayed indicating whether or not the test data would be a valid entry.

To directly edit the regular expression that comprises the validation entry, select the Advanced tab. The expression is displayed in the Regular Expression field and may be amended as required. For help on editing Regular Expressions, click on the help link displayed on this tab.

12.12:131© 2011 AVEVA Solutions Ltd

Page 150: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Automatic Tag Format Sub-SetIf valves are to be tagged automatically (see 6.10.25: Automatic Tagging), the format of valve tags is defined using this sub-category.

Note: Do not set up automatic valve tagging if inheritance to the valve tag field is to be used (see above).

12.12:132© 2011 AVEVA Solutions Ltd

Page 151: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

If automatic tagging is to be used, check the Apply Project based Auto Tagging checkbox.

The format of automatic valve tags is defined in the Tag Expression field. A preview of a tag using the current definition is displayed in the Sample Tag Valve field.

1. In the Tag Expression field, enter any fixed values such as prefixes and delimiters (e.g. V-).

2. If valve tags are to include valve properties, select the property from the list in the Available Data Properties field, then place the cursor where the property is to be located in the expression and select the Insert Property button. The list of properties is taken from the attributes of a DataSet defined for this purpose (see Defining Valve Tag Properties for Automatic Valve Tagging).

The selected property is added to the expression like so: [name of property].3. If valve tags are to include owner pipe properties, select the property from the list in the

Available Pipe Properties field, then place the cursor where the property is to be located in the expression and select the Insert Property button.

The selected property is added to the expression like so: [name of property].4. If valve tags are to include an automatically incrementing number, place the cursor in

the expression where this number is to be located, and select the Insert Counter button.

The counter is added to the expression like so: [Counter]. 5. Enter the number that the counter is to be incremented by for each valve in the

Increment By field. Select the length of the counter number from the list in the Format field.

6. To clear the Tag Expression field, select the Clear button.

If a counter is in use, it may be reset to 0 for the project by selecting the Reset Counter button.

12.12:133© 2011 AVEVA Solutions Ltd

Page 152: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Patterns Sub-Set

The Pattern application pane is used to edit the definitions of project valve patterns.

The application pane consists of two sections. The first section of the application pane is used to add, amend and delete pattern definitions.

12.12:134© 2011 AVEVA Solutions Ltd

Page 153: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Existing Patterns Section

The first section contains a list of existing patterns and three tools for managing patterns - Add Pattern, Delete Pattern and Rename Pattern.

- Adding a New Pattern

If a new pattern is to be created, select the Add Pattern…. hyperlink. The following dialog box is then displayed:

Enter a unique value for the pattern name and press the OK button

The dialog box will be closed and the new value is displayed in the Existing Patterns list box.

- Deleting a Pattern

If a pattern is to be deleted, select the Deleted Pattern…. hyperlink. The following dialog box is then displayed:

To proceed with the deletion select Yes. If the value is not to be deleted select No.

12.12:135© 2011 AVEVA Solutions Ltd

Page 154: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

If Yes is selected the dialog box will be closed and the pattern deleted from the Existing Patterns list box. All associated pattern property data is deleted.

- Renaming a Pattern

If a pattern is to be renamed, select the Rename Pattern…. hyperlink. The following dialog box is then displayed:

Enter a unique value for the pattern name and press the OK button

The dialog box will be closed and the amended name is displayed in the Existing Patterns list box.

- Patterns Components Section

The second section contains a grid, which is used to manage the components of a pattern.

Create a new row is created by selecting the button. The following dialog box is then displayed:

Enter the sequence number of the new row. The new row then is created at the bottom of the grid.

The first valve specified will be the substitute item. All other items will be component items. Only a single valve can be specified. All other items must be line fittings.

• Sequence No FieldNormally the item handle forms the unique identifier for an item exported to VPE Workbench. However, component pattern items do not posses such a handle. To overcome this lack, the handle of the substitute item is used together with an asterisk and the sequence number of the component item, e.g., AB*1, where AB is the substitute valve handle, and 1 is the sequence number of the component item.

12.12:136© 2011 AVEVA Solutions Ltd

Page 155: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

If there are no sequence numbers in the file, an error will occur on output.

If pattern valve data has been loaded into VPE Workbench and the pattern is then changed on the P&ID, the existing sequence numbers should be maintained. For example, if the sequence was 1, 2, 3, and 2 was removed - the new sequence should be 1, 3, not 1, 2. This is to avoid inconsistencies which would occur if the pattern was reloaded into VPE Workbench.

Sequence numbers cannot be edited in the grid. The sequence number row must be deleted and re-entered with a new name.

• Symbol Name FieldSubstitute Item: Enter the symbol name of the valve that is to be the substitute item. Only a single valve may be specified in a valve pattern.

Component Item: Enter the symbols names here for component line fitting items. Symbol names can be identified using the Symbols Configuration Category of the AVEVA P&ID Project Administration program or from the item Properties dialogs.

• P&ID Substitute Item FieldA pattern can consist of any number of component items, but only one substitute item is permitted. This is automatically the first valve defined. The substitute item is denoted by a "Yes" in this field.

• Description FieldEnter a description of each item as required.

12.12:137© 2011 AVEVA Solutions Ltd

Page 156: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.18 Line Fittings Configuration Category

The Line Fittings Configuration Category consists of the Settings sub-category:

The application pane is divided into four sections.

12.12:138© 2011 AVEVA Solutions Ltd

Page 157: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Line Fittings Symbol SectionThis section contains the following settings:

• Line Fittings Label Symbol. If this checkbox is checked a symbol will be placed with line fittings labels. For example, a box may be placed around the labels.

• Symbol Name. This field is used to select the name of the symbol that will be placed with the line fitting labels.

• Symbol X Offset. The X offset to the line fitting type letters label. • Symbol Y Offset. The Y offset to the line fitting type letters label.

• Line Fittings Label Position Section The Prefix, Type Letter, Number, and Suffix Position fields in this section are used to set the X and Y coordinates of line fitting label components.

• Inheritance SectionThis section contains the following settings:

• If item labels are to be inherited from owner pipes, the fields to be inherited from for each label are specified in the Prefix, Type, Number and Suffix fields.

• The Browse button adjacent to these fields is used to select the fields to be inherited from. On selection of the button, the following dialog box is displayed:

The fields required are selected using the drop down lists. Following selection, press OK. The selected fields will then be displayed in the Prefix, Type, Number and Suffix fields.

• The values of line settings labels may be inherited from the sheet attributes entered on the Advanced Drawing Properties sheet. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design

12.12:139© 2011 AVEVA Solutions Ltd

Page 158: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

area. The inheritance facility enables all items to inherit these common values. The labels of items that do not share these common values may subsequently be edited manually using their properties sheets.

The Fields from Sheet Attribute fields are used to select which line settings label fields are to inherit values from which sheet attributes. As required, select for each line settings label field the sheet attribute field from which values are to be inherited.

Note that if a line settings label field is already set to inherit from the owning pipe (see above), this Fields from Sheet Attribute field will not be accessible. Pipe label inheritance takes priority over sheet attribute inheritance.

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

- Label Validation Across P&IDs Section

The project may be set to check that all special piping item line fitting labels in all P&IDs in a project are unique.

• Select the Prevent button if users are to be prevented from entering project duplicate line fitting labels. If this is attempted, an error message is displayed and the duplicate label may not be placed on the P&ID.

• Select the Warn button if users are to be warned if they enter project duplicate line fittinglabels. The entry of duplicate labels is permitted in this case, but an error message will be displayed on the P&ID, and will accompany the valve label data when transferred to VPE Workbench.

• If no uniqueness validation of line fitting labels across P&IDs is required, select Ignore button. Duplicate line fitting labels may be entered in different P&IDs in this case.

Note that if the Prevent or Warn options are set, a connection to the VPE Workbenchdatabase must be established before labels can be edited. This is because in order to check the uniqueness of labels across a project, AVEVA P&ID refers to data that is extracted from the VPE Workbench database.

12.12:140© 2011 AVEVA Solutions Ltd

Page 159: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.19 Nozzles Configuration Category

The Nozzles Configuration Category is divided into two sub-categories:• Settings Sub-Set • Labels Sub-Set

• Settings Sub-Set

If nozzle sizes are to cascaded onto connecting pipes, check the Cascade Nozzle to Pipe checkbox.

• Labels Sub-Set

If nozzles are to be labelled using an automatically incrementing number, check the Increment Nozzle Sequence checkbox.

If nozzles labels are to automatically include a prefix, enter this prefix in the Nozzle Prefix field. If no prefix is required, enter <NONE> (the default entry).

The Increment Nozzle Sequence checkbox is disabled if <NONE> is entered in the Nozzle Prefix field, or if the field is blank.

12.12:141© 2011 AVEVA Solutions Ltd

Page 160: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.20 Offsheet Connector Configuration Category

The Offsheet Connector Configuration Category consists of the Labels sub-category:

The application pane is divided into four sections.

12.12:142© 2011 AVEVA Solutions Ltd

Page 161: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Display Label FormatThe Display Label Format Fields field is used to select order in which pipe flag label field are displayed. Fields may appear in a different order from those of the "actual" label.

The Browse button adjacent to the field is used to select the format. On selection of the button, the Display Label Format dialog box is displayed:

Using the drop-down lists, select the order in which the parts of pipe flag fields are to be displayed. If required, enter a delimiter to be displayed between the two label components in the other field.

Click OK. The selected format is then displayed in the Display Label Format Fields field.

If pipe flag fields are to be "fixed", i.e. the two parts are to displayed concatenated as single strings that cannot be split on a drawing, check the Fix Label Format checkbox.

• Flags SectionThe Flags Positioned at field defines the default arrangement of pipe flags that are positioned on pipes as they are drawn. From the drop down list, select the value that corresponds to the required value (none -0, start only -1, end only -2, or at both ends -3).

• Default Off-Sheet Connector for Pipe End StylesThese fields set the default flag style (symbol type PFL) for flags positioned at the start and end of pipes. Select the symbol type from the drop down lists.

• Connector Label SettingsThis grid is used to specify the default insertion points for the different label types that may be used to label pipe flags, relative to the pipe flag symbols they are labelling.

If labels of a type are to be placed in a fixed position, enter Y in the Fix Position field.

Enter the label type positions relative to pipe flag symbols in the X and Y fields.

12.12:143© 2011 AVEVA Solutions Ltd

Page 162: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.21 Miscellaneous Configuration Category

The Miscellaneous Configuration Category is divided into three sub-categories: • Settings Sub-Set• Labels Sub-Set • Validation Sub-Set

12.12:144© 2011 AVEVA Solutions Ltd

Page 163: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Settings Sub-Set

12.12:145© 2011 AVEVA Solutions Ltd

Page 164: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The application pane is divided into seven sections.

- Miscellaneous Settings Section

This section contains the following settings: • To turn on online validation (see 6.13.1: Label Validation against Lists of Valid Values),

check the On-Line Data Validation checkbox. • The Dialog Boxes checkbox controls whether or not dialog boxes will be in use for the

project. If checked, a project will have dialog boxes and Properties dialogs in use. If unchecked, they will not be available.

• If VPE Workbench data placed on a drawing is to be automatically refreshed whenever a connection to VPE Workbench is made, the Auto Refresh VPE Workbench Data checkbox must be checked.

• If item labels are to inherit data from owning pipes the Inherit Item Labels from Owner Pipes checkbox must be checked. Checking this checkbox enables this facility for the entire project. Inheritance details are specified using the appropriate AVEVA P&IDAdministrator Configuration Category, i.e. Instruments, Equipment (for inline equipment), Valves or Line Fittings.

• If an image of the symbol being labelled is to be displayed at the bottom of Properties dialogs, ensure the Use the Docviewer checkbox is checked.

• Select the non-plotting layer from the Non-Plotting Layer Name field. The list will consist of the names of layers as set up using the Drawing - Layers Sub-Set.

• From the Error Symbol Name field, select the name of the symbol which will indicate errors on project P&IDs.

- Text Position from Origin Section

In the Text position from origin fields, enter the X and Y coordinates that specify the position that error message text is placed in, relative to the error symbol.

- Setting Colour for Display During Synchronize

This section is used to specify the text colours of the error and warning messages that may be displayed on drawings when they are synchronized.

The Browse buttons adjacent to the Colour for warning and Colour for errors fields are used to select the colour.

12.12:146© 2011 AVEVA Solutions Ltd

Page 165: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

On selection of the button, the colour selection dialog box is displayed:

The Colour Code can be selected using the following methods: • Selection of one of the colours shown in the palette • By double clicking the Assume Owner Colour hyperlink. Messages will automatically

assume the colours of the item they are associated with • By double-clicking on the Assume By Layer hyperlink. Messages will automatically

assume the colours of the layers they are on.• By manually entering the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in the Symbol Colour field.

- Values to Remember from Last Nozzle Edit Section

This section contains two checkboxes - Tag and Size.

A project can be configured so that a value entered in a field in a Properties dialog is "remembered" by the same field when that Properties dialog is accessed again when labelling another, previously unlabelled, item of that type.

If, for example, the functionality is switched on for the nozzle Tag field, and a nozzle is labelled with a value of "N-0001". The next time a nozzle is labelled for the first time, when the Properties dialog for this item is opened, the Tag field will automatically be completed with the value "N-0001". This can be replaced by another value if required. This new value will then be the "remembered" value for the nozzle Tag field.

This functionality is switched on and off for individual Properties dialog fields by checking and unchecking the checkboxes in this section.

- Default OSnap Section

If the default object snap setting of the project is that snapping should be to the nearest point, ensure that the Nearest button is pressed.

If "smart" snapping is to be the default, ensure that the Smart button is pressed. Snapping will then default to End, Intersection, Perpendicular etc as appropriate.

If snapping is to be off by default, ensure that the Osnap Off button is pressed.

12.12:147© 2011 AVEVA Solutions Ltd

Page 166: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Auto Save Section

This section is used to control the AutoCAD Auto Save facility.

To enable or disable this facility check or uncheck the AutoSave checkbox as required.

In the Save Interval field enter the interval between the automatic saves. This may also be set for individual users in the user start up routine (see 2.9: Customisation Guide).

- User Defined Directives Section

This section is used to set up the names and values of directives to be used in user-defined VBA macros.

Enter the names and values of each directive in the grid fields.

If a directive is to be added, select the button. The following dialog box is then displayed:

Enter a unique name and press the OK button. The dialog box will be closed and the entered new directive will be displayed in the grid.

To edit a directive name, select the button and enter the new value in the dialog that is then displayed.

12.12:148© 2011 AVEVA Solutions Ltd

Page 167: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Directives for Export to ISO15926 Files

If data is to be exported from drawings to XML files in ISO15926 format, the following directives should be set up. These directives control the XML schema that is to be used, and the appearance of the SVG files used to view the exported drawings in P&ID Manager and PDMS.

Name Values Notes

USER_BACKCOLOUR BLACK or WHITE Specifies the background colour of drawings in SVG files

USER_LINEWEIGHTFACTOR Number Specifies the relative line width of lines in the SVG files compared to lines in AVEVA P&ID.

For example:

If 1 is entered the widths will be the same.

If 2 is entered, line widths will be multiplied by 2 in the SVG files compared to those in the AVEVA P&ID files.

If 0.5 is entered, they will be half the size.

USER_SCHEMAVERSION 3_2 or 3_3 Specifies the ISO15926 XML schema to be used, 3.2.0 or 3.3.3.

3.3.3 should only be used if exporting to version 12.0 SP5 of PDMS or later.

12.12:149© 2011 AVEVA Solutions Ltd

Page 168: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Labels Sub-Set

The application pane is divided into four sections.

- Auto-Labelling Section

If pipe labels and routes are to be validated automatically after they are drawn, ensure the Auto-Validate checkbox is checked.

The rest of the auto-labelling checkboxes control whether the properties sheets used for labelling items are to be automatically displayed or not after an item in a particular category of items is drawn or placed on a P&ID.

For example, if the Properties dialog for labelling pipes is to be automatically displayed after a pipe is drawn, check the Auto-Label Piping checkbox.

- Revision Symbols Section

The Label Offset from Symbol Origin fields on this pane define the X and Y coordinates which specify the position that revision triangles are placed in, relative to the insert point of the revised symbol.

12.12:150© 2011 AVEVA Solutions Ltd

Page 169: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

If grid references of revised symbols are to be placed on P&IDs, ensure that the Place Grid-Reference of each Symbol checkbox is checked. Note that these grid references are not updated if revised symbols are subsequently moved.

- Typical Labelling Section

This section contains the following settings: • The Typical Labelling checkbox is used to enable or disable the typical items function.

If it is checked, Typicals options will be enabled on item shortcut menus. • If typical data is already on a P&ID and the checkbox is unchecked, then the data will

remain on the P&ID, but the Typicals options will remain greyed out. The data will also be ignored when an output is performed from the P&ID with a warning message being displayed to indicate that typical data exists, but is not exported.

• The colours of typical pipes, pipe flags, instruments, equipment, SPPs, valves and nozzles are set in the following fields provided. • Pipe Typical Colour. • Pipe Flag Typical Colour. • Instrument Typical Colour. • Equipment Typical Colour. • SPP Typical Colour. • Valve Typical Colour. • Nozzle Typical Colour.

When labelled as typical, the item labels will change to these colours. If these colours are changed at a later date, after typical data has been entered onto the drawing, the colours will be updated when AVEVA P&ID is re-loaded.

• The Browse button adjacent to the typical colour fields is used to select the colour this field.

On selection of the button, the colour selection dialog box is displayed:

The Colour Code can be selected using the following methods: • Selection of one of the colours shown in the palette

12.12:151© 2011 AVEVA Solutions Ltd

Page 170: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• By double clicking the Assume Owner Colour hyperlink. Items will automatically assume the colours of the owning items, e.g., the colours of the lines they are inserted into. When there is no owning item, they will be set to the default colour.

• By double-clicking on the Assume By Layer hyperlink. Items will automatically assume the colours of the layers they are inserted into, as set on the Layers Sub-Set the Drawing Configuration Category.

• By manually entering the Colour Code field

Following selection, press OK. The selected colour code will then be displayed in the grid.

- Dialog Box Field Labels Section

The Dialog Box Field Labels section contains four fields, which are used to specify the boilerplate text to replace the defaults of Prefix, Tag, Number and Suffix on the Properties dialog for labelling Special Piping Items.

In the Delimiter After Field 1, 2 and 3 fields, enter the delimiters used to separate the fields.

Note that these delimiters are not displayed on P&IDs or in the Engineering Explorer. They are used to ensure tag format consistency when exporting to PDMS via the ISO15926/P&ID Manager interface.

• Validation Sub-Set

- Nozzle and Special Piping Items Label Field Validation Sections

These sections are used to specify the permitted format of entries into selected nozzle and SPP label fields.

In the fields provided, enter the following characters as required:

Code Description

A Upper Case Alpha Character [A-Z]

a Lower Case Alpha Character [a-z]

M Mixed Case Alpha Character [A-Z, a-z]

F Upper Case Free Character [A-Z, 0-9, white space]

12.12:152© 2011 AVEVA Solutions Ltd

Page 171: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

For example, if AaN is entered for the Prefix Field field, when a user is completing this field in the SPP labelling Properties dialog, the first character must be an uppercase letter, the second a lower case letter, and the third a number.

The Advanced Format Options dialog is available from the button adjacent to each field.

To test how the validation will work in practice, make an entry in the Test Data field of the Test tab, and press the Test button. A message will be displayed indicating whether or not the test data would be a valid entry.

To directly edit the regular expression that comprises the validation entry, select the Advanced tab. The expression is displayed in the Regular Expression field and may be amended as required. For help on editing Regular Expressions, click on the help link displayed on this tab.

f Lower Case Free Character [a-z, 0-9, white space]

X Mixed Case Free Character [A-Z, a-z, 0-9, white space]

N Numeric Character [0-9]

Code Description

12.12:153© 2011 AVEVA Solutions Ltd

Page 172: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.22 Excel Interface Configuration Category

The Excel Interface Configuration Category consists of the Settings sub-category:

12.12:154© 2011 AVEVA Solutions Ltd

Page 173: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Export to Excel - excelout SectionThis section is used to select the format of Excel spreadsheets exported from AVEVA P&ID: Item Type or Item Group.

If a spreadsheet is in the Item Type format, data for each item type that was exported is displayed on its own worksheet.

If a spreadsheet is in the Item Group format, item type data is grouped into item categories: pipes, instruments, equipment, valves, line fittings, reducers, nozzles and off-sheet connectors. There is a worksheet for each category.

• Import to P&ID - excelin SectionThis section is used to select the item types imported from Excel spreadsheets into AVEVA P&ID, e.g. drawing attributes, equipment, pipes etc, are to have data imported from the NEW columns on the spreadsheets.

• Filter for Excel - excelfiler SectionThis section is used to select the default types of items to be exported to Excel spreadsheets from AVEVA P&ID, e.g. drawing attributes, equipment, pipes etc. If required, a different set of item types from these defaults can be selected for each individual export procedure.

12.12:155© 2011 AVEVA Solutions Ltd

Page 174: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.23 Spec Driven Configuration Category

The Spec Driven Configuration Category is used to control which symbols can be inserted into pipes based on the specification of those pipes.

Note: When a project is upgraded, in order for Spec Driven data and functionality to be available, the database schema must be updated by selecting the Upgrade Specdriven Database Schema - Upgrade button in the Project Database Configuration Category.

The Spec Driven Configuration Category is divided into three sub-categories: • Symbols Sub-Set• Add/Edit Specs Sub-Set• Assign Specs Sub-Set

The Symbols sub-category is used to specify valid pipe specifications for individual symbols. The Add/Edit and Assign Specs sub-categories are used to specify valid pipe specifications to groups of symbols.

12.12:156© 2011 AVEVA Solutions Ltd

Page 175: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Symbols Sub-Set

For example, it may be specified that Ball Valve symbols may only be inserted into pipes with a specification of AAA3, and an inlet bore size of 20 and an outlet bore size of 20.

Multiple combinations of pipe specs and sizes may be specified as compatible with the insertion of a symbol. If no specs or sizes are specified for a symbol, insertion of this symbol is unrestricted.

Spec/size insertion restrictions may be set up for Valves, Instrument Valves and Reducers.

Currently, only restrictions for 2-way symbols may be specified, but not symbols inserted at pipe junctions such as 3-way and 4-way valves.

Note: Changes to drawings resulting from changes to Spec Driven settings are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded. See 8.2.4: Updating Spec Driven Data.

12.12:157© 2011 AVEVA Solutions Ltd

Page 176: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Specifying the Valid Specs and Pipe Sizes for the Insertion of a Symbol

Note: Valid specification and size data can be imported from an AVEVA PDMS project. See PDMS Cats and Specs Import below.

To specify the specs and sizes of pipes that a symbol may be inserted into:

1. From the list of values at the top of the application pane, select the symbol.

2. From the list of values below this, select the symbol.

The selected symbol is displayed next to the list.

Note: Symbols are set up using the Symbols Configuration Category.

3. From the bore sizes grid, select the inlet and outlet size by clicking on the cell at the intersection of these values. The vertical axis displays the inlet size, the horizontal axis displays the outlet size. The selected cell is displayed with a blue background.

Note that only light grey cells can be selected.

12.12:158© 2011 AVEVA Solutions Ltd

Page 177: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

In the case of Valves and Instrument Valves, only those cells at the intersection of identical bore size values can be selected, as valves have the same inlet and outlet sizes.

In the case of Reducers, only those cells at the intersection of different bore size values can be selected, as reducers must have different inlet and outlet sizes.

Note: The list of sizes is set up using the List of Values Configuration Category.

4. From the list of pipe spec codes, select the code or codes. To select a code from the list, click on it. The spec code is then highlighted with a blue background. Multiple codes can be selected.

To de-select a spec code, click on it again. The code will no longer be highlighted in the list, and will be removed from the cell in the table.

12.12:159© 2011 AVEVA Solutions Ltd

Page 178: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Spec codes can be copied and pasted from one cell to another. To copy the contents of a cell, right-click and select the Copy option from the menu that is then displayed.

To paste into a cell, right-click on the cell and select the Paste option from the menu.

Note: The list of pipe spec codes is set up using the List of Values Configuration Category.

5. Repeat steps 3 and 4 for each valid combination of spec and bore sizes for the symbol.6. To populate all cells with every code from the list of spec codes, select the Set as

Default button. Individual codes may then be de-selected if required for each cell, as described above.

7. To clear every cell in the grid of codes, select the Clear button.

- Insertion Options

These settings control what happens when symbols are inserted into pipes with specs and/or sizes that the symbols are not valid for. These settings are applicable to all symbols that are subject to this functionality, not just the one selected at the top of the application pane.

• Select the Prevent button if users are to be prevented from inserting a symbol into a pipe with a spec and/or size that the symbol is not valid for. If this is attempted, an error message is displayed and the symbol is not placed on the P&ID.

• Select the Warn button if users are to be warned if they insert an invalid symbol. The insertion of the symbol is permitted in this case, but an error message will be displayed on the P&ID, and will accompany the symbol when transferred to VPE Workbench. Invalid symbols are displayed on the P&ID in a specific colour (see below)

• If the specs and sizes of pipes are to be ignored when inserting symbols, select Ignore button.

The Out of Spec Symbol Warning Colour at P&ID field is used to specify the colour of symbols that are not valid for the spec and/or size of the pipe that they are inserted into (see the Warn option above).

12.12:160© 2011 AVEVA Solutions Ltd

Page 179: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To select a colour, press the green button next to the field. On selection of the button, the colour selection dialog box is displayed:

The Colour Code can be selected by selection of one of the colours shown in the palette, or by manually entering the Colour Code field.

Following selection, press OK. The selected colour code will then be displayed in the grid.

- PDMS Cats and Specs Import

Valid specs and sizes can be imported from a PDMS project.

In the Paragon Module of PDMS, a report must be run on the specifications in question (see Spec Driven Data Import from PDMS - PML Function and Report).

The contents of this report can then be imported into the project settings of an AVEVA P&ID project.

1. Press the green button next to the Spec Report Location field, and browse for the PDMS report. By default, the report will be called spco.report and will be located in the c:/temp folder.

2. Check the Use Report to Populate Specification List of Values checkbox.3. Press the Import Spec Report to Database button.4. The import then takes place. The grid in the Symbols pane is then automatically

populated with valid symbol spec and size data from the PDMS project. Existing settings are replaced.

• Spec Driven Data Import from PDMS - PML Function and ReportA PML function can be adapted by a customer to filter the Specification data. The order in which the data is listed must as described below as the code to import the data into P&ID relies on this. The correct order is:

Specification Name, Symbol Name, Catalogue Reference, Bore 1, gtype, bore2

These must be delimited by a one space character. The PML for this is:

!temp = !spec & ' ' & !name & ' ' & !catref & ' ' & !bore & ' ' &!gtype & ' ' & !bore2

12.12:161© 2011 AVEVA Solutions Ltd

Page 180: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Where ‘!temp’ is a temporary string.

AVEVA P&ID will display the report correctly only if the names from the report (from PDMS) correspond to the symbol names configured at the P&ID Project Administrator. Verify that the report is correctly imported by revising the P&ID project database at the Project Projmet folder, e.g.:

C:\AVEVA\P&ID\Project\IPE\Autocad\Projmet\IPE.mdb

Below is a sample PML function report:

/A1A /A1A/RE500x400:500_400 /AARE2001Y 500 REDU 400

/A1A /A1A/XER:500_400 /XAARE2001Y 500 REDU 400

/A1A /A1A/RC500x450:500_450 /AARC2001Z 500 REDU 450

/A1A /A1A/RE500x450:500_450 /AARE2001Z 500 REDU 450

/A1A /A1A/XER:500_450 /XAARE2001Z 500 REDU 450

/A1A /A1A/RC600x400:600_400 /AARC2003Y 600 REDU 400

/A1A /A1A/RE600x400:600_400 /AARE2003Y 600 REDU 400

/A1A /A1A/XER:600_400 /XAARE2003Y 600 REDU 400

/A1A /A1A/RC600x450:600_450 /AARC2003Z 600 REDU 450

/A1A /A1A/RE600x450:600_450 /AARE2003Z 600 REDU 450

/A1A /A1A/XER:600_450 /XAARE2003Z 600 REDU 450

/A1A /A1A/RC600x500:600_500 /AARC20031 600 REDU 500

/A1A /A1A/RE600x500:600_500 /AARE20031 600 REDU 500

/A1A /A1A/XER:600_500 /XAARE20031 600 REDU 500

/A1A /A1A/RE600x550:600_550 /AARE20032 600 REDU 550

/A1A /A1A/XER:600_550 /XAARE20032 600 REDU 550

/A1A /A1A/KT15 /A0KD330D0 15 CAP 0

/A1A /A1A/KD15 /A0KD530D0 15 CAP 0

/A1A /A1A/KT20 /A0KD330E0 20 CAP 0

/A1A /A1A/KD20 /A0KD530E0 20 CAP 0

/A1A /A1A/KC65 /AAKC200K0 65 CAP 51

/A1A /A1A/KC80 /AAKC200L0 80 CAP 64

/A1A /A1A/KC100 /AAKC200N0 100 CAP 76

/A1A /A1A/KC150 /AAKC200R0 150 CAP 102

/A1A /A1A/KC200 /AAKC200T0 200 CAP 127

/A1A /A1A/KC250 /AAKC200V0 250 CAP 152

/A1A /A1A/KC300 /AAKC200W0 300 CAP 178

/A1A /A1A/KD25 /A0KD330F0 25 CAP 0

/A1A /A1A/KD40 /A0KD330H0 40 CAP 0

/A1A /A1A/KD50 /A0KD330J0 50 CAP 0

12.12:162© 2011 AVEVA Solutions Ltd

Page 181: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

/A1A /A1A/KM15 /ABKM600D0 15 PCOM 0

/A1A /A1A/KM20 /ABKM600E0 20 PCOM 0

/A1A /A1A/VG15 /A0VG3X0DD 15 VALV 45

/A1A /A1A/VH15 /A0VH3X0DD 15 VALV 33

/A1A /A1A/VC15 /A0VC3X0DD 15 VALV 60

/A1A /A1A/GA-1117:15 /VGVG5XRDD 15 VALV 21

/A1A /A1A/GL-1132:15 /VGVH5XRDD 15 VALV 28

/A1A /A1A/CK-1429:15 /A0VJ5X0DD 15 VALV 26

/A1A /A1A/VG20 /A0VG3X0EE 20 VALV 56

/A1A /A1A/VH20 /A0VH3X0EE 20 VALV 38

/A1A /A1A/VC20 /A0VC3X0EE 20 VALV 64

In the generated report care must be taken to remove (if apply) the preceding “/” from the symbol names. The names must correspond to the P&ID Project Administrator symbol names. Please note these values can be also changed at project SQL database.

• Add/Edit Specs Sub-Set

The Add/Edit Specs sub-category is used to create specifications which are groups of piping specification codes links to an item type or an item group (Instrument Valves, Reducers or Valves).

Specific symbols within the item type or item group can then be assigned to the specification using the Assign Specs Sub-Set.

12.12:163© 2011 AVEVA Solutions Ltd

Page 182: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

To create a specification:

1. Select the Create Specification Template button. The Add Specifications dialog is then displayed:

2. If the specification is to be for an item type, select the Item Type button. If it is to be for an item group, select the Item Group button.

3. Enter the name of the specification in the Spec Name field.4. From the list in Item Type field, select the item type of item group that the specification

is for.5. Click OK to save the spec.6. The dialog remains open so that further specs can be created if required, as described

in steps 2 to 5. Click Done to close the dialog.7. From the bore sizes grid, select the inlet and outlet size by clicking on the cell at the

intersection of these values. Then, from list of pipe spec codes, select the code or codes. See the description of the Symbols Sub-Set for details.

8. Select the Save button to save the specification. Specific symbols can now be assigned to the specification using the Assign Specs Sub-Set.

To edit an existing specification, select the specification from the list available from the Select Specifications field and then edit the bore sizes/pipe spec codes as required.

To delete a specification, open it as described above, then select the Delete button.

12.12:164© 2011 AVEVA Solutions Ltd

Page 183: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Assign Specs Sub-Set

12.12:165© 2011 AVEVA Solutions Ltd

Page 184: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Assign Specs sub-category is used to assign symbols to specifications created using the Add/Edit Specs sub-category.

To edit an existing specification, select the specification from the list available from the Select Specification Template field and then edit the bore sizes/pipe spec codes as required.

The grid beneath the Spec Name field then displays the valid bore size/pipe specification associations set using the Add/Edit Specs sub-category. They cannot be edited here.

- Assigning Symbols to Specifications

The grid beneath the bore size/pipe specification associations grid displays all the symbols of the item type or item group of the specification. The name and description of each symbol is listed. To assign a symbol to the spec, check its Select checkbox.

To assign all the listed symbols, check the Select All Symbols checkbox. The Select checkbox for every symbol is then checked.

When all the required symbols have been selected, select the Assign button to complete the procedure.

- Insertion Options

The Spec Driven Symbols and Out of Spec Symbol Warning Colour at P&ID controls are used to control what happens when symbols are inserted into pipes with specs and/or sizes that the symbols is not valid for. These settings are applicable to all symbols that are subject to this functionality.

See the description of the Symbols Sub-Set for details.

12.12:166© 2011 AVEVA Solutions Ltd

Page 185: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.24 User Defined Attributes Configuration Category

The User Defined Configuration Category is divided into two sub-categories:• UDA List of Values Sub-Set• DataSet Sub-Set

Each sub-category is concerned with one of the two types of User Defined Attributes (UDAs) that may be used in AVEVA P&ID:

• Attributes added to symbols and pipes using the standard AutoCAD Attribute Definition dialog, accessed from the Symbol Editor. Lists of valid values for these attributes can then be selected using the UDA List of Values sub-category.

• DataSet UDAs are groups of attributes that are set up for types of items or symbols that meet user-defined criteria. They are defined using the DataSet sub-category.

• UDA List of Values Sub-Set

The UDA List of Values application pane is divided into two sections.

The upper section is used to scan the symbols in the projects for UDAs. These are then listed in the lower section, which is used to select which lists of values are to be used when entering values for these UDAs on project drawings.

To scan for UDAs, check the Project Symbol Path and/or the Standard Symbol Path checkboxes to specify which project symbol directories are to be scanned. Select the Scan button.

12.12:167© 2011 AVEVA Solutions Ltd

Page 186: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

All detected UDAs are then displayed in the lower section of the pane (all UDAs previously scanned by the Project Administrator will already be listed).

To specify a list of values, select it from the list in the appropriate LOV Name field. The default selection is <NONE>, i.e. no list of values is selected.

Lists of values are set up on the List of Values Configuration Category of the Administration program.

• DataSet Sub-Set

12.12:168© 2011 AVEVA Solutions Ltd

Page 187: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

- Creating a DataSet

1. To create a new DataSet, select the Create New DataSet button. The Add New DataSet dialog is then displayed.

2. Enter the name of the new DataSet in the DataSet Name field.3. The Criteria section is used to define the criteria that will specify which item the

DataSet will be applied to. For example, for a particular type of equipment, or for equipment in general.

From the Item Type list, specify whether or not the criterion will be applied to an item class name, item group or symbol name.

4. From the Criteria list, select the required operator, e.g. equal to (=) etc,

12.12:169© 2011 AVEVA Solutions Ltd

Page 188: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

5. From the Item Value list, select the required class name, item group or symbol name.

6. The Condition list is used if multiple criteria are to be used. Select AND to specify that the DataSet is to be applied to items that meet both criteria.

7. When the required settings for the first criterion have been defined, select the Add button. The details of the criterion are then displayed in the lower of the dialog.

8. If another criterion is to be defined, change the settings in the Criteria fields as required and select the Add button again. The second criterion is then added to the list of criteria.

12.12:170© 2011 AVEVA Solutions Ltd

Page 189: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

In this example, the DataSet will be applied to all items that are in either the Equipment or Instrument item groups.

9. To delete a criterion, select it from the list and press the Delete button.10. When all required criteria have been defined, select the Save button to save changes

and close the dialog. The DataSet name and criterion are displayed in the DataSet List and Criterion fields on the DataSet Sub-Set pane.

To close the dialog without saving any changes, select the Cancel button.

- Defining DataSet Attributes

To define the attribute or attributes that comprise a DataSet, first select the DataSet from the DataSet List field. The item selection criteria of the DataSet (see above) are then displayed in the Criterion field.

1. Attributes are defined and displayed in the grid in the lower part of the DataSet Sub-Set

pane. To add an attribute, select this button from the toolbar above the grid: . The Add New Attribute dialog is then displayed.

2. In the Attribute Name field, enter the name of the attribute. This name will be the title of the field used to enter the value for the attribute on the Properties dialogs of items that meet the DataSet criteria.

3. From the Data Type list field, select String.4. If the values for this attribute are to be selected from a list of values, select this list from

the LOV field. Lists of values are set up on the List of Values Configuration Category of the Administration program.

12.12:171© 2011 AVEVA Solutions Ltd

Page 190: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

5. If the Properties dialog field for the attribute is to be automatically completed with a default value from the select list of values, select it from the Default Value field list.

6. Select the Save button to save changes and close the dialog. The attribute details are then displayed in the grid.

7. To close the dialog without saving any changes, select the Cancel button.

Repeat the above procedure for each attribute required for the DataSet.

- Editing and Deleting DataSets

To edit or delete a DataSet, select the DataSet from the DataSet List field. The item selection criteria of the DataSet (see above) are then displayed in the Criterion field.

To edit the DataSet, select the Edit Criterion button. The Edit DataSet Criterion dialog is then displayed with the existing properties of the DataSet displayed. Edit them as required as described above.

Attribute names cannot be edited. The attribute row must be deleted and re-entered with a new name.

To delete the DataSet, select the Delete DataSet button.

- Defining Valve Tag Properties for Automatic Valve Tagging

If valves are to be tagged automatically (see 6.10.25: Automatic Tagging), the format of valve tags is defined on the Automatic Tag Format Sub-Set of the Valves Configuration Category. The list of valve properties that are available for selection when defining this format are taken from a DataSet which must be set up for this purpose, as follows:

• The DataSet name must be "Valves"• The DataSet criteria must be "Item_Group = Valve"• Attributes may then be defined as required

12.12:172© 2011 AVEVA Solutions Ltd

Page 191: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

For example:

Note that if the DataSet is not set up, or no attributes are defined for it, automatic valve tagging may still be used, but the valve tags cannot include any of the attributes of the valves.

- Defining the Pipe Groups DataSet

If pipes are to be allocated to groups for reporting purposes, the names and optionally the default values associated with these groups must be specified in a DataSet.

The DataSet must be defined as follows:• The DataSet name must be "PIPE_GROUPS"• The DataSet criteria must be "Item_Group = Pipes"

Specify the name of each pipe group in the Attribute Name fields. If required, enter the default user-defined attribute to be assigned to each pipe group in the Default_Value fields.

12.12:173© 2011 AVEVA Solutions Ltd

Page 192: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

For example:

12.12:174© 2011 AVEVA Solutions Ltd

Page 193: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.25 User Access Configuration Category

The User Access Configuration Category consists of the User Access Settings sub-category:

The sub-category is used to change the password required to access the Administration program if the Login as Administrator with password (SQL Server Security) option is selected in the Project Database Configuration Category.

In the Password field enter the current password.

Note: The default password is "Admin".

In the Enter New Password field enter the new password.

In the Confirm New Password field enter the new password again.

Select the Change button to implement the new password.

12.12:175© 2011 AVEVA Solutions Ltd

Page 194: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.26 PDMS Integration Configuration Category

The PDMS Integration Configuration Category consists of the PDMS Settings sub-category:

If the AVEVA Schematic Database node is not to be displayed in the P&ID Data Grid, check the Hide PDMS Node in P&ID checkbox.

The Project Name and Database Name field are used to specify the default entries for the Project and MDB fields in the PDMS Login dialog.

Select the location of PDMS installation that the AVEVA P&ID project is to interface with in the PDMS Version (Installation Location) field.

Note: The earliest version of PDMS that AVEVA P&ID can interface with is 12.0.SP5.

Note: Configuration is also required in PDMS to set up the interface between AVEVA P&ID and PDMS. See 9.9: Setting up PDMS to Connect with P&ID for details.

12.12:176© 2011 AVEVA Solutions Ltd

Page 195: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.27 AI Integration Configuration Category

The AI Integration Configuration Category is used to specify settings for the integration of AVEVA P&ID and AVEVA Instrumentation. It consists of the AI Settings sub-category:

If the AVEVA Instrumentation node is not to be displayed in the P&ID Data Grid, check the Hide AI Node in P&ID checkbox.

In the Derive Instrument AREA from field, if required, select the AVEVA P&ID Instrument tag field which will be populated with the Area values of instruments imported from AVEVA Instrumentation (AI).

In the Derive Loop AREA from field, if required, select the AVEVA P&ID Loop tag field which will be populated with the Area values of loops imported from AVEVA Instrumentation (AI).

12.12:177© 2011 AVEVA Solutions Ltd

Page 196: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.28 AVEVA NET Configuration Category

The AVEVA NET Configuration Category is divided into four sub-categories: • Configurations Sub-Set• Mappings Sub-Set• Setting Sub-Set• Advanced Options Sub-Set

• Configurations Sub-Set

The Settings sub-category is used to specify general settings for the AVEVA NET interface, relating to the format of the files generated by the export from AVEVA P&ID.

For detailed information, refer to the AVEVA NET Schematic Gateway Configuration Guide.

• Mappings Sub-Set

12.12:178© 2011 AVEVA Solutions Ltd

Page 197: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The mappings between AVEVA P&ID format data and AVEVA NET Portal format data are stored in sets of three XML files, one for each of the following types of mapping:

• Presentation Mapping • Attribute Mapping• Class Mapping

This sub-category is used to select the mapping files to be used.

For detailed information, refer to the AVEVA NET Schematic Gateway Configuration Guide.

• Setting Sub-Set

The Settings sub-category is used to specify general settings for the AVEVA NET interface, relating to the format of the files generated by the export from AVEVA P&ID.

For detailed information, refer to the AVEVA NET Schematic Gateway Configuration Guide.

12.12:179© 2011 AVEVA Solutions Ltd

Page 198: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• Advanced Options Sub-Set

The Advanced sub-category is used is to export data to a remote location, and to export data from multiple project drawings.

- AVEVA NET Service Section

Drawing data already generated by an AVEVA NET export may be transferred to a remote location, for example a shared network folder, using a AVEVA NET server service.

If this facility is to be used, check the Transfer files to Remote AVEVA NET Server checkbox.

12.12:180© 2011 AVEVA Solutions Ltd

Page 199: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

In the AVEVA NET Service Path field, enter the location of the AVEVA NET server service. Select the Test button to test that the location of a functional service has been entered. If so, message is displayed to confirm this:

In the Remote Server Publishing Location field, enter the remote folder into which output files are to be copied.

Select the Transfer button to copy all the files currently in the local staging area (as specified on the Configurations sub-category) to the remote location. A message is displayed once the transfer is complete.

- Batch Publish option to AVEVA NET Section

The Project drawings available list displays all those project drawings from which data can exported.

To select a drawing to export data from, select it and select the > button.

To select multiple drawings to export data from, select them and select the >> button.

To select all available drawings to export data from, select the button with the green arrow on it.

Selected drawings are moved from the Project drawings available list to the Drawings selected for publish list.

Use the < and << buttons to de-select single or multiple drawings and move them back to the Project drawings available list.

Select the button with the red cross button on it to de-select all selected drawings.

When all required drawings have been selected, select the Apply button.

Carry out the export using facilities available in the Log Options section.

- Log Options Section

To generate export files from the drawings selected in the Batch publish option to AVEVA NET section, select the Start button.

The export then takes place. The progress of the export is indicated by a progress bar.

12.12:181© 2011 AVEVA Solutions Ltd

Page 200: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Details of the export or displayed in the log window below it.

To stop the export, select the Stop button.

To clear the log window, select the Clear button.

To view the log in the log file generated as part of the export, select the View Log button.

12.12:182© 2011 AVEVA Solutions Ltd

Page 201: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.3.29 AE Integration Configuration Category

The AE Integration Configuration Category is used to specify settings for the integration of AVEVA P&ID and AVEVA Electrical. It consists of the AE Settings sub-category:

If the AVEVA Electrical node is not to be displayed in the P&ID Data Grid, check the Hide AE Node in P&ID checkbox.

In the Derive Equipment AREA from field, if required, select the AVEVA P&ID Equipment tag field which will be populated with the Area values of equipment imported from AVEVA Electrical (AE).

12.12:183© 2011 AVEVA Solutions Ltd

Page 202: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.4 Changing Units on a Project If, in mid-project, it is decided that a units change must occur, either from metric to imperial or vice versa, a change must be made to the labelling units setting in the project configuration file using the Project Configuration Category of the AVEVA P&ID Project Administration program.

Note: Changing the project drawing units is not possible.

Set labelling units to metric or imperial on the Project pane of the AVEVA P&ID Project Administration program. AVEVA P&ID should not be loaded while this file is being edited. The units on existing drawings will only be converted on reload into AVEVA P&ID.

Note: ONLY the labelling units will change and NOT the physical size of the graphical symbols.

Note: Changes to drawings resulting from the label units being changed are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded. See 8.2.5: Convert Project Label Units.

If an attempt is made to insert metric symbols into an imperial drawing, they will be inserted 25.4 times bigger than intended due to the 25.4 mm:1" ratio. To correct this it is necessary to edit the symbol lengths using the Symbols Configuration Category of the AVEVA P&IDProject Administration program.

In order to carry out these conversions, AVEVA P&ID uses a file located in the validation directory, named CONV.UNI. An excerpt from this file is shown below:

3 = 1/8"

6 = 1/4"

10 = 3/8"

25.4 = 1" etc

Comment lines to begin with a * character. Sizes shown are in <mm>=<inches>.

2.4.1 Associated Project Configuration Options • Specify the size of the snap spacing using the Snap Spacing field on the Drawing - Grid

Sub-Set of the AVEVA P&ID Project Administration program. • Specify the size of grid spacing using the Grid Spacing field. • The drawing and label units used on the project are set using the buttons on the Project

Configuration Category pane. These should not be changed once the project has begun.

2.5 Defining Project Symbols

2.5.1 Creating a New Symbol Symbols can be drawn and edited using the Symbol Editor.

See Symbol Editor for a description of this facility.

To create a new symbol without using this facility, proceed as follows:

12.12:184© 2011 AVEVA Solutions Ltd

Page 203: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

1. If running AVEVA P&ID on a networked setup, ensure that AVEVA P&ID is not in use anywhere on the network. Without initialising AVEVA P&ID, load an existing AVEVA P&ID drawing and locate an existing item of similar size and AVEVA P&ID type to the new symbol. Measure its length and width to get some idea of scale.

2. Using AutoCAD drawing commands, draw the new item at the required size on a new AVEVA P&ID drawing dialog, again without AVEVA P&ID being initialised. Make the item into a block, carefully picking an insertion point which is at the centre of a symmetrical object or at the left hand end of a non-symmetrical one. For angled, 3 way and 4 way valves, the insertion point should be at the centre, not at the bottom, or the pipes will not break correctly.

3. There are no restrictions on linestyles, colours or naming conventions during symbol creation. However, when AVEVA P&ID inserts a symbol, the colours may alter according to layer/level settings in the project configuration file. Symbols can be manipulated after insertion, for example, rotated, or mirrored. This reduces the required number of standard symbols in a library.

4. Ensure that the block is available to all users, i.e., by using WBLOCK in AutoCAD, and place in the \PMETSYM or \PIMPSYM project symbol directory or import using the Symbols Configuration Category of the AVEVA P&ID Project Administration program. Enter the properties of the new symbol in the Symbols pane.

5. Attempt to insert the symbol in order to test the new item with AVEVA P&ID now initialised (see Inserting Symbols - General Information). Check the correct insertion point has been selected when creating the block and that the graphical creation angle is correct. If any errors occur, edit the symbol using the Administration program, re-load the drawing, initialise AVEVA P&ID again and retest.

6. If a metric symbol is inserted into an imperial drawing or an imperial symbol into a metric drawing, it will be inserted at the wrong scale. To correct this, edit the symbol length in the Symbols pane.

2.5.2 Upgrading Symbols from Old ProjectsFor projects developed before AVEVA VPE P&ID 7.2 SP3, an upgrade of the symbols on the project drawings is required.

Refer to 2.1: Upgrading Pipes and Symbols from old Projects.

2.5.3 Avoiding Problems when using Client SymbologyA client will often specify the symbols which are to be employed when drawing P&IDs for a project. In these instances, the standard symbol library may not be acceptable. The following points should be addressed situation:

• Check to see if an AVEVA P&ID symbol library, together with its AVEVA P&ID file, exists for the client elsewhere. This library can then be used without having to set up a completely new set of symbols, and therefore can save time and effort.

• If an AVEVA P&ID symbol library does not exist for the client, the client may still have their symbols in AutoCAD drawings as blocks. These can then converted to symbols using one of several utilities available for this purpose. These utilities are obtainable by calling AVEVA P&ID Technical Support. Their functionality is detailed in the Symbol Utility Programs section. AutoCAD block colours should be set to BYBLOCK prior to them becoming AVEVA P&ID symbols.

• If the client symbols exist only on paper or in an untranslatable graphics format, they will have to be redrawn in AutoCAD.

2.5.4 Symbol Utility Programs The following AutoLISP programs described below:

12.12:185© 2011 AVEVA Solutions Ltd

Page 204: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• CLEANATT.LSP • CREATSYM.LSP • REMATTS.LSP

However, they have not been issued as part of the AVEVA P&ID installation kit. To request installation contact AVEVA P&ID Technical Support.

• CLEANATT.LSP Used to remove all existing attribute values from all blocks on an existing AutoCAD drawing. Attributes must be removed from blocks before they are converted to symbols. This utility may be needed from time to time to remove client attributes before relabelling using AVEVA P&ID. The blocks remain intact and a prompt is still received for new attribute values if new insertions are performed.

- Syntax:

Enter: CLEANATT

This will remove all attribute values.

The Command prompt will display:

Are you sure <Y/N>:

Enter Y

A regeneration is performed and the command ends.

• CREATSYM.LSP Project symbol data is stored in the PID.SYM file. This utility is used to append information from existing AutoCAD blocks to an existing AVEVA P&ID PID.SYM file or to create a new correctly formatted PID.SYM.

- Syntax:

Enter: CS

The first block highlights and is panned to the centre of the screen.

The Command prompt will display:

Add symbol to sym file Y/N:

If N is entered, the next symbol is highlighted and panned to the centre of the screen.

If the symbol is already in the PID.SYM file, it will be missed out automatically.

Enter Y for Yes.

12.12:186© 2011 AVEVA Solutions Ltd

Page 205: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The prompt will then display

AVEVA P&ID type e.g. VLV:

Enter a valid item type.

The Command prompt will then display:

Does symbol break pipe Y/N:

Enter Y for Yes.

The Command prompt will then display:

Symbol size - 1st point:

Pick 2 points to show the width of the symbol.

The Command prompt will then display:

2nd point: Offset point:

The insertion point is found by AVEVA P&ID - pick one of the width points.

The Command prompt will then display:

How many insert points 1/2:

Enter 1 or 2.

The Command prompt will then display:

Creation angle <0.0>:

Enter angle.

The Command prompt will then display:

Graphical Tracing <Y>/N:

Enter Y.

12.12:187© 2011 AVEVA Solutions Ltd

Page 206: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The Command prompt will then display:

Tracewidth point:

Pick a point above the object where tracing should be placed.

The Command prompt will then display:

Description:

Enter Test Valve.

The command then moves onto the next block.

• REMATTS.LSP Used to explode existing AutoCAD blocks, remove all attributes completely and remake the block under the same name.

- Syntax:

Enter: REMATTS

The Command prompt will display.

Select object:

Pick existing block.

The command finishes.

12.12:188© 2011 AVEVA Solutions Ltd

Page 207: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.6 Defining a New Pipe Style Pipe styles can be created and edited by selecting the Pipe Styles option on the List of Values Configuration Category of the AVEVA P&ID Project Administration program.

2.7 Defining a New Signal Line Type Simple signal line styles can be created and edited using the Signal Styles Configuration Category of the AVEVA P&ID Project Administration program.

More complex line styles can be created using the following procedure.

This procedure is based on the AutoCAD functionality for defining complex Line Styles. For more information please see the AutoDesk website:

http://usa.autodesk.com/adsk/servlet/item?siteID=123112&id=2671814&linkID=9240615

1. The first step is to open a project drawing and draw the shape that is going to be used in the new line type (by using AutoCAD geometries: circles, lines, arcs, etc.). For instance:

2. Next, use the “MKSHAPE” command to convert the geometry into a Shape object. The application will ask for the location to save the file. Specify the Bin directory at:

C:\...........\Aveva\P&ID\Install\AutoCad\Bin

12.12:189© 2011 AVEVA Solutions Ltd

Page 208: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Type the name of the file, in this example “Twocir”, and click Save:

At the command prompt, the application will ask for the name of the shape and other parameters:• “Enter the name of the Shape: TCI” - (e.g. “TCI”).• “Enter resolution <128>:” - “Enter” to select the default option.• “Specify the insertion point:” - select at the screen the insertion point, for

instance the west quadrant of the circle.• “Select Objects:” - select the circle and the line and press “Enter”.

The command prompt will display “Shape "TCI" created. Use the SHAPE command to place shapes in your drawing".

3. The next step is to insert the previously defined shape in the drawing area by using the SHAPE command. After the command is entered the application will display:

“Enter Shape name or [?]” - in this case enter TCI. Press “Enter”.

“Insertion point” - select any point in the drawing area.

”Specify height <1.0000>” - press “Enter” to use the default value.

“Specify rotation angle <0>:” - press “Enter” to use the default value.4. Once the Shape is inserted into the drawing area, the next step is to use the command

“MKLTYPE” to define the parameters of the line type in a “.lin file”. In this case save the .lin file at the “Projmet” folder at (in this example under the IPE project):

C:\........\Aveva\P&ID\Project\IPE\Autocad\Projmet

12.12:190© 2011 AVEVA Solutions Ltd

Page 209: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

For example:

The command prompt will then display:• “Enter linetype name: LTN” - e.g. LTN.• “Enter Linetype description: Circle and Line” - e.g. Circle and Line.• “Specify starting point for line definition:” - e.g. at the screen left

end, west quadrant of the circle.• “Specify ending point for line definition:” - e.g. select any point

near to the right end point of the line. For example:

12.12:191© 2011 AVEVA Solutions Ltd

Page 210: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

• "Select Objects:” -select the previously inserted shape and press Enter. The command prompt will the display “Linetype "LTN" created and loaded".

5. Delete from the drawing area the previously inserted geometries and shape and save and close the P&ID application.

6. The Style Lines used by each project are defined in the “acad.lin” file at:

C:\Aveva\P&ID\Project\IPE\Autocad\Projmet

For example:

Next, open the next “.lin” files located at the “Projmet” folder by using Notepad:• “acad.lin”• “TST.lin” previously defined

Copy (Ctrl-C) all the lines from the “TST.lin”:

12.12:192© 2011 AVEVA Solutions Ltd

Page 211: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Paste them at the end of the “acad.lin” file:

Save the “acad.lin” file and close it. 7. The next step is to configure the new Signal Style using the Project Administrator. In

the Signal sub-category of the Item Types Configuration Category (see Signal Sub-Set), create a new Signal Type by selecting the “insert row” button.

Then define:• The name of the new Signal Type, in this case “STS”• The Drawing layer: for instance “AS_INST” • The colour: for instance “2”• Description: for instance “Signal Line (demo)”.

Save the Project Administrator.

12.12:193© 2011 AVEVA Solutions Ltd

Page 212: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

8. The next step is to define the Signal Style using the Signal Styles Configuration Category. Insert a new Signal Style by using the “Insert row" button and enter the signal name, for instance “CIRDEMO”:

9. The next step is to define the parameters of the new Signal Style:• In the “P&ID type” field, select the previously configured STS Signal Type • In the “Line Type” field select the previously configured LTN Line Type • Finally, in the “Signal Type” field enter the name displayed in the “Signal Styles”

dropdown menu in the P&ID application, for instance “DEMO”. See below:

12.12:194© 2011 AVEVA Solutions Ltd

Page 213: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

10. Finally save the Project Administrator, open the P&ID application and test the new Signal Style in a drawing. It will be available for selection from the list of signal styles in the Signal Line Group of the Home Tab.

2.8 Defining a New Tracing StyleTracing styles can be created and edited using the Tracing Configuration Category of the AVEVA P&ID Project Administration program.

2.9 Customisation Guide

2.9.1 Introduction The graphical user interface in AVEVA P&ID is fully customisable. Users can alter the toolbars, right click menus, pull down menus and add start up routines to suit their project needs.

• Start-up Routines • Explorers • Right Click Menus • Toolbars • Menus • Adding Custom Lisp Routines to AVEVA P&ID • Adding new multi line styles in AVEVA P&ID • Running AVEVA P&ID in "Save To Model Mode" • Auto Save Settings • Project Profiles • Complex Linetypes

See also: • 2.10: Customising the AVEVA P&ID Tool Palette

2.9.2 Start-up Routines Taking advantage of the AutoCAD VBA interface, AVEVA P&ID automatically loads a VBA routine called "UserStartUp" located in the Users module.

By altering the start up routine users can easily modify toolbars and menus, and control whether the Engineering Explorer loads automatically or not. To access this routine, after AVEVA P&ID has been loaded, type VBAIDE at the command prompt.

In the VBA editor go to the VBA project explorer and double click the module Users" and select "UserStartUp".

Note that when a project is upgraded, by default, the users.dvb module is overwritten. However, the upgrade wizard includes an option to preserve it.

Listed below is an example of the start up routine:

Public Sub UserStartUp() '' This macro will start up automatically with the application. '' WARNING: Any routine placed here will be run every time a drawing loads...

12.12:195© 2011 AVEVA Solutions Ltd

Page 214: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Dim UsersClass As UserUtils Dim BatchFile As String Dim defdir As String Dim SaveToModelFlag As Boolean Dim UserPreferences As AcadPreferencesUser Dim USerName As String Dim Password As String Dim Connection As String Dim PlotfileName As String Dim ErrorMode As Boolean Dim FreezeNonPlotLayer As Boolean Dim PrinterName As String Dim f As Long Dim Utils As Object Dim AutoSave As String Dim AutoSaveFlag As String

On Error Resume Next ' Get an instance of Public Class UserUtils Set UsersClass = New UserUtils ' Set User preferences for right click menu, disable AutoCAD short cut menus... Set UserPreferences = ThisDrawing.Application.Preferences.User UserPreferences.ShortCutMenuDisplay = False ' Get ruth of Project directory using Directive DATDIR defdir = UsersClass.GetDefaultDirectory ' Find out if there is a savetoModel bath file to run in batch mode... If Right(defdir, 1) = "\" Then

BatchFile = defdir & "SaveToModel.Bat" PlotFile = defdir & "PidPlot.Bat" BatchConfig = defdir & "pidplot.txt"

Else BatchFile = defdir & "\SaveToModel.Bat" PlotFile = defdir & "\PidPlot.Bat" BatchConfig = defdir & "\pidplot.txt"

End If If UsersClass.FileExists(PlotFile) Then '' User must set default values here...

PlotfileName = "" PrinterName = "" NumberOfCopies = 1

12.12:196© 2011 AVEVA Solutions Ltd

Page 215: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

ErrorMode = False FreezeNonPlotLayer = True '' PlotConfig = defdir & "HP LaserJet 5Si.pc3" PlotConfig = "" BatchPlot.Show If Len(PlotConfig) > 3 And InStr(UCase(PlotConfig), "PC3") <> 0 Then

UsersClass.PlotActiveDrawing PlotfileName, PlotConfig, NumberOfCopies, ErrorMode, FreezeNonPlotLayer, PlotPrinter Set UsersClass = Nothing Application.ActiveDocument.Close False Application.Quit Exit Sub

End If End If '' If save To Model Batch File exist then '' Application will run in Save To Model Mode.... If UsersClass.FileExists(BatchFile) Then

' Save To Model -- SAVE TO DB SET TO: TRUE ' Create Output Files Only SET TO FALSE SaveToModelFlag = False '' USERNAME, PASSWORD AND CONNECTION STRING MUST BE SET HERE If SaveToModelFlag Then

USerName = "SPROC" Password = "SPROC" Connection = "vpe53dev1"

End If UsersClass.SaveToModelInBatchMode USerName, Password, Connection, SaveToModelFlag

Else ''Enable Right Click menu -- Default UsersClass.EnableRightClickMenu '' Load Explorer Application.ActiveDocument.SendCommand "ASEXPLORER" & vbCr DoEvents '' Delete VPE P&ID 2nd Toolbar Row ''Application.ActiveDocument.SendCommand "ASDELTOOLBARS" & vbCr ''DoEvents '' LOADS VPE P&ID 2nd Toolbar Row ''Application.ActiveDocument.SendCommand "ASLOADTOOLBARS" & vbCr ''DoEvents

12.12:197© 2011 AVEVA Solutions Ltd

Page 216: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

'' Modify Toolbars ans rearreange P&ID Menus '' UsersClass.ModStandardTBar '' Modify Standard menus ''UsersClass.ModStandardMenu ' Set Right Click Menu Status... '' Disable Rigth click Menu ''UsersClass.DisableRightClickMenu '' Set return Key to Right Click Menu ''UsersClass.SetRightClickToReturnKey '' Audit and fix errors in drawing as they are loaded... ''UsersClass.AuditActiveDrawing '' Validate all pipes mark as invalid (RED) in the explorer '' Could take a long time in "heavy" drawings... ''UsersClass.ValidateAllPipes '' Set Drawing LImits to match Project setting for Drawing Length and Height UsersClass.SetDrawingLimits '' Set AutoSaveIntervals from project settings UsersClass.SetProjectAutoSaveTimeSettings

End If

2.9.3 Explorers The following options are available for the Project and Symbol Explorers:

1. Do not display Engineering Explorer on start up

Remove or "comment out" (i.e. add a quotation mark at the start of the line) the following line from the "UserStartUp" routine.

Application.ActiveDocument.SendCommand "ASEXPLORER" & vbCr

Whether or not the Symbol Explorer is displayed on start up is controlled at project level.

2. Display Project and Symbol Explorers in Floating Mode on start up

If the default display mode of the Explorers is to be floating, proceed as above, but then "comment in" (i.e. remove the quotation mark) from the following line:

Application.ActiveDocument.SendCommand "ASEXPLORERFLOAT" & vbCr 3. Display Project and Symbol Explorers in Docking Mode on start up

If the default display mode of the Explorers is to be docking, no changes are required.

Note that the above only apply the first time a user starts a project session. Subsequently, the Explorers are automatically displayed in the position and mode they were in at the end of the user's previous session.

2.9.4 Right Click Menus The following options are available for right click menus:

12.12:198© 2011 AVEVA Solutions Ltd

Page 217: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

1. Disable AVEVA P&ID default right click menus

To disable AVEVA P&ID default right click menu, just "comment in" in the following line from the "UserStartUp" routine.

"UsersClass.DisableRightClickMenu

When the AVEVA P&ID right click menu is disabled the standard AutoCAD right click behaviour will be active instead.

2. Set Right click button to return key

To the right click button press in AVEVA P&ID to act as the return key just comment in the following line from the "UserStartUp" routine.

"UsersClass.SetRightClickToReturnKey 3. Enable right click menu (default)

No changes required.

To customise right click menus programmatically, use the "BeginRightClick" event of the "AcadDocument" object.

Private Sub AcadDocument_BeginRightClick(ByVal PickPoint As Variant)

‘ Write your mouse right click event here….

End Sub

See the AutoCAD customisation guide for more details on customising right click menus.

2.9.5 Toolbars The "ModStandardTBar" method of the "UserUtils" class in the "UserStartUp" routine controls the display of the toolbars first loaded when AVEVA P&ID is opened.

It is possible to modify standard behaviour of toolbars during the loading process by altering this method.

Commenting out this method will allow users to control toolbars by editing the menu files (PID.MNU, ACAD.MNU).

See the AutoCAD customisation guide for more details on customising MNU files.

Note: The second toolbar is critical to the application and therefore can not be altered or disabled by users.

2.9.6 Menus The "ModStandardMenu" method of the "UserUtils" class controls the display of the pull down menus loaded by the application.

It is possible to modify standard behaviour of pull down menus during the loading process by altering this method.

Commenting out this method will allow users to control pull down menus from the menu files (PID.MNU, ACAD.MNU).

See the AutoCAD customisation guide for more details on customising MNU files.

2.9.7 Adding Custom Lisp Routines to AVEVA P&ID Lisp routines can be added to "acaddoc.lsp" located at the Bin folder of the standard installation.

12.12:199© 2011 AVEVA Solutions Ltd

Page 218: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Below is an example of a lisp routine supplied with version 6.1.0.16 that creates the command "ai_selall" which selects every entity in the active drawing.

;;;----------------------------------------------------------------------------

; New "Select All" function. Cannot be called transparently.

(defun c:ai_selall ( / ss old_error a b old_cmd old_hlt)

(setq a "CMDECHO" b "HIGHLIGHT"

old_cmd (getvar a) old_hlt (getvar b)

old_error *error* *error* ai_error)

(if (ai_notrans)

(progn

(princ "Selecting objects...")

(setvar a 0)

(setvar b 0)

(command "_.SELECT" "_ALL" "") ; Create Previous SS

(setvar a old_cmd)

(setvar b old_hlt)

(setq ss (ssget "_P"))

(sssetfirst ss ss) ; Non-gripped, but selected (someday!)

(princ "done.\n")

)

)

(setq *error* old_error old_error nil ss nil)

(princ)

)

Some sample lisp programs are supplied in the BIN folder of the standard installation.

Warning: Lisp routines that modify intelligent entities in AVEVA P&ID drawings could potentially corrupt entities and drawings as a consequence.

2.9.8 Adding new multi line styles in AVEVA P&IDMulti line styles are stored in a file called PID.MLN. A copy of this file is supplied with AVEVA P&ID which includes a number of default multi lines styles. This file loads automatically when AVEVA P&ID is loaded.

To provide a set of specific multi-lines styles for a project you must add a new path to the Support File Search Path A copy of this file must be placed at this location.

To achieve this, use command preferences and access the "Support File Search Path" node of the "Files" tab.

The path priority is set from top to bottom.

Below there is a sample of a multi-line style set in the PID.MLN supplied with version 6.1.0.16.

MLSTYLE

2

12.12:200© 2011 AVEVA Solutions Ltd

Page 219: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

MULTI-MAIN

70

0

3

62

6

51

90.00000000000000

52

90.00000000000000

71

2

49

1.5000000000000000

62

6

6

BYLAYER

49

-1.5000000000000000

62

6

6

BYLAYER

0

See the AutoCAD customisation guide for more details on creating new multi line styles.

See also AVEVA P&ID Files - PID.MLN.

2.9.9 Running AVEVA P&ID in "Save To Model Mode" In order to run Save to Model (see 8.8.5: Synchronising Data with a VPE Workbench Database) on multiple drawings in a project use the supplied "MakeSaveToModelBatch" routine.

Before running the routine some editing may be required (see sections in bold below). To access the routine, type VBAIDE at the command prompt. In the VBA editor go to the VBA project explorer and double click the "Users" module node, and select "MakeSaveToModelBatch". Run or edit the routine as required.

The routine can also be edited and run by selecting the Make Synch Batch File option from the .AVEVA Integration Group of the Data Management Tab.

Below is an example of the routine supplied with version 6.1.0.16.

Public Sub MakeSaveToModelBatch()

'' Create Batch File to run SaveToModel in multiple drawings located at one folder....

'' After batch file is created, exit the application and run batch file from command prompt.

12.12:201© 2011 AVEVA Solutions Ltd

Page 220: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Dim AcadLocation As String

Dim AcadProfile As String

Dim AcadConfig As String

'' Please Specify Location of ACAD.EXE in your system

AcadLocation = "C:\Program Files\AutoCAD 2002\acad.exe" '' Specify Active Configuration file

AcadConfig = "C:\Program Files\AutoCAD 2002\acad2002.cfg" '' P&ID Profile

AcadProfile = "PID61"

On Error Resume Next

Dim Uclass As UserUtils

Set Uclass = New UserUtils

Uclass.CreateSaveToModelBatchFile AcadLocation, AcadConfig, AcadProfile, Application.ActiveDocument.FullName

Set Uclass = Nothing

End Sub

Below is an example of the batch file generated by this routine.

CD "C:\Projects\RUYTER"

"C:\Program Files\AutoCAD 2002\acad.exe" /c "C:\Program Files\AutoCAD 2002\acad2002.cfg" "C:\Projects\RUYTER\Flowsheets\SaveToModel\144-000-PR-PID-0005.dwg" /p PID61

"C:\Program Files\AutoCAD 2002\acad.exe" /c "C:\Program Files\AutoCAD 2002\acad2002.cfg" "C:\Projects\RUYTER\Flowsheets\SaveToModel\144-000-PR-PID-0011.dwg" /p PID61

"C:\Program Files\AutoCAD 2002\acad.exe" /c "C:\Program Files\AutoCAD 2002\acad2002.cfg" "C:\Projects\RUYTER\Flowsheets\SaveToModel\144-000-PR-PID-0012.dwg" /p PID61

"C:\Program Files\AutoCAD 2002\acad.exe" /c "C:\Program Files\AutoCAD 2002\acad2002.cfg" "C:\Projects\RUYTER\Flowsheets\SaveToModel\144-000-PR-PID-0013.dwg" /p PID61

"C:\Program Files\AutoCAD 2002\acad.exe" /c "C:\Program Files\AutoCAD 2002\acad2002.cfg" "C:\Projects\RUYTER\Flowsheets\SaveToModel\144-000-PR-PID-0014.dwg" /p PID61

DEL "C:\Projects\RUYTER\SaveToModel.Bat"

The first line must point to the root of the project folder where the PID.PRJ (project catalogue) file is located.

Additional changes must be made to the routine “UserStartUp” to match the project requirements.

To Save the drawing data to a project database the flag “SaveToModelFlag” must be set to True. Also, the username, password and connection string must be set to match the user database.

' Save To Model -- SAVE TO DB SET TO: TRUE

12.12:202© 2011 AVEVA Solutions Ltd

Page 221: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

' Create Output Files Only SET TO FALSE

SaveToModelFlag = True '' USERNAME, PASSWORD AND CONNECTION STRING MUST BE SET HERE

If SaveToModelFlag Then

USerName = "SPROC"

Password = "SPROC"

Connection = "vpe53dev1"

End If

Note: After the routine ends the file will be automatically deleted. To ensure AVEVA P&IDwill run in editing mode ensure the file “SaveToModel.Bat” is deleted from the root of the project folders.

2.9.10 Auto Save Settings By default, the AutoCAD Auto Save interval for a user, and whether this facility is active, is derived from the project configuration settings. See the 2.3.21: Miscellaneous Configuration Category of the AVEVA P&ID Project Administration program for details.

In order to override these project settings for an individual user, the following code in the “UserUtils” macro can be edited: The macro is accessible from Users” module of the VBA editor as described above.

Public Function SetProjectAutoSaveTimeSettings()

'' Set Autosave intervals according to value set in the project

Dim Value As String

Dim AutoSaveFlag As String

Dim SaveIntervals As String

Dim Pref As AcadPreferences

On Error Resume Next

Set Pref = Application.Preferences

AutoSaveFlag = "AUTOSAVE"

SaveIntervals = "SAVEINTERVAL"

Value = UCase(GetProjectDirective(AutoSaveFlag))

If Trim(Value) = "YES" Then

Value = UCase(GetProjectDirective(SaveIntervals))

Pref.OpenSave.AutoSaveInterval = CInt(Value)

Else

Pref.OpenSave.AutoSaveInterval = 0 End If

12.12:203© 2011 AVEVA Solutions Ltd

Page 222: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Err.Clear

End Function

Edit the highlighted line as required, e.g.

Pref.OpenSave.AutoSaveInterval = 40

2.9.11 Project Profiles When the project wizard is run it will create a profile, the name of which matches project name, which contains project specific information. In the unlikely event that the project name needs to be changed, the project wizard Upgrade an Existing Project, or the Install Project Shortcut Only option must be run in order to create new a project profile. An error will result if the project profile name does not match project name as displayed in the Project Configuration Category of the AVEVA P&ID Project Administration program.

Customisation of project profiles, such as the changing of background colours, will only affect the current project and not the software in general.

2.9.12 Complex LinetypesCustomisation can be applied by creating complex linetypes for use by project pipes, signal lines etc.

See:

http://usa.autodesk.com/adsk/servlet/item?siteID=123112&id=2671814&linkID=9240615

2.10 Customising the AVEVA P&ID Tool Palette • Introduction• Grouping Palettes• Creating New Groups and Palettes• Adding Signal and Process Lines to the Tool Palette• Adding Symbols to the Tool Palette

2.10.1 Introduction The AutoCAD Tool Palette has been customised to give users another way of creating and inserting symbols and intelligent lines, and to execute various other AVEVA P&IDcommands.

The functionality is available with AVEVA VPE P&ID 6.2 patch 14. After this patch is installed, to make the AVEVA P&ID palette available, the Project Wizard upgrade routine must be run.

Once the project is upgraded, the palette can be accessed from the drawing editor either by pressing CTRL+3, by entering TOOLPALETTES at the command line, or by selecting the option Tool Palettes Window from the AutoCAD Tools pull down menu.

12.12:204© 2011 AVEVA Solutions Ltd

Page 223: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.10.2 Grouping Palettes When the project is first loaded after the upgrade, the sample palette that is distributed with the patch will be displayed in a single group called All Palettes:

12.12:205© 2011 AVEVA Solutions Ltd

Page 224: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The set of distributed palettes match AVEVA P&ID standard project configuration. To make the palettes easy to navigate through, it is advisable to group them. To group tool palettes, select the Customize… option from the Tool Palette right-click menu:

The AutoCAD Customize dialog box will then be displayed:

A sample group is provided, located in the folder:

\\Aveva\P&ID\Install\AutoCad\Bin\palettes

12.12:206© 2011 AVEVA Solutions Ltd

Page 225: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

The folder contains a group file called Standard.xpg, which can be loaded by right-clicking at the palette group list box and selecting the Import option:

Browse to the indicated location and select the standard.xpg file:

12.12:207© 2011 AVEVA Solutions Ltd

Page 226: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

After the group file has been loaded it, the Palette Groups displayed in the Customizedialog box will look like this:

Palettes have been allocated to sub-groups to facilitate navigation around the tool palette:

12.12:208© 2011 AVEVA Solutions Ltd

Page 227: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Close the Customize dialog box and access the Tool Palette right-click menu. The groups will now be accessible:

2.10.3 Creating New Groups and Palettes To add new groups, right-click and select the Customise… option, then and right-click in the Palette Groups pane and select the New Groups option. See the AutoCAD development guide documentation for more details.

To add new palettes, navigate to the group in which the palette is to be created, right-click and select New Palette:

The new palette must then be given a valid name. See the AutoCAD development guide documentation for more details.

12.12:209© 2011 AVEVA Solutions Ltd

Page 228: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.10.4 Adding Signal and Process Lines to the Tool PaletteNavigate to the Lines sub group using the right-click menu:

Each of the icons displayed on the tool palettes are called Tools. Right-click on one of the tool icons and select Copy:

12.12:210© 2011 AVEVA Solutions Ltd

Page 229: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Then paste the icon into the same palette, or into any other as required:

Then right-click and select the Properties option of the new tool icon. The Tool Propertiesdialog is then displayed:

Enter a name and a description.

12.12:211© 2011 AVEVA Solutions Ltd

Page 230: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Right-click on the image and select Specify Image to browse for a 32x32 bitmap to represent the new tool (this step is optional).

In the case of signal lines, in the Command string field enter:

^C^C(c:asdrawsignal "Signal Description")

Where:

^C^C cancels any ongoing operation in AutoCAD.

ASDRAWSIGNAL is a command that is used to insert signal lines.

"Signal Description" is the name of the signal line to be inserted.

The signal line is then available for insertion from the Tool Palette.

Note that the signal must exist in the project. The list of valid signal lines can be viewed in the Signal Line Group of the Home Tab:

In the case of process lines, in the Command string field enter:

^C^C(c:asdrawpipe "Pipe Style Description")

Where:

^C^C cancels any ongoing operation in AutoCAD.

ASDRAWPIPE is a command that is used to insert pipes.

"Pipe Style Description" is the name of the pipe to be inserted.

Pipes in the new style are then available for insertion from the Tool Palette (see 8.5.1: Drawing Pipes).

12.12:212© 2011 AVEVA Solutions Ltd

Page 231: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Note that the pipe style must exist in the project. The list of valid pipe styles can be viewed in the Pipeline Group of the Home Tab::

12.12:213© 2011 AVEVA Solutions Ltd

Page 232: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

2.10.5 Adding Symbols to the Tool Palette It is recommended that new symbols be assigned new pictures. To add a picture to the Tool Palette, drag and drop an existing symbol from a drawing (for instance from a legend dialog) into the Picture Catalogue palette:

The symbol must have been present in the drawing prior to the last drawing save.

To add a new symbol, copy and paste a tool icon from any of the existing symbol palettes (e.g. the Picture Catalogue palette) into the palette in which the new symbol tool icon is to be located.

12.12:214© 2011 AVEVA Solutions Ltd

Page 233: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Then access the Properties dialog for the tool.

12.12:215© 2011 AVEVA Solutions Ltd

Page 234: aveva p&id

AVEVA P&ID 12.1 User GuideProject Configuration

Enter a name and a description, and optionally select a representative image:

In the Command string field enter either:

^C^C(c:ASMINSERT "Symbol Name")

or

^C^C(c:ASINSERT "Symbol Name")

Where:

^C^C cancels any ongoing operation in AutoCAD.

ASMINSERT and ASINSERT are commands used to insert symbols.

ASMINSERT is used to insert multiple instances of the same symbol.

ASINSERT is used to perform a single symbol insert.

"Symbol Name" is the name of the symbol to be inserted.

The symbol is then available for insertion from the Tool Palette (see 8.4.1: Inserting Symbols - General Information).

The symbol name must exist in the project symbol catalogue. Refer to the Project Administrator symbol catalogue or the AVEVA P&ID Symbol Explorer to view the project symbol names and description.

12.12:216© 2011 AVEVA Solutions Ltd

Page 235: aveva p&id

AVEVA P&ID 12.1 User GuidePrinciples and Concepts

3 Principles and Concepts

3.1 Good Drawing Practice The following points should be observed when drawing P&IDs:

• Label all instruments, equipment, pipes, bypasses, spec breaks as fully as possible. • All Pipe On/Off flags should be labelled. • Do not forget to label reducers in labelled pipes. • Always ensure when editing a P&ID that the AS_NONPLOT layer is On. Stretching,

moving or editing the drawing with this layer Off will compromise drawing integrity and may inadvertently leave Start or End nodes online labels in the wrong position. Do not stretch pipes with the NON PLOTTING layer turned Off.

• Always use the correct symbol. Incorrect symbols will be seen as a different item to the one intended in the validation. If the correct symbol is not available, a new one should be made.

• Some LISP files contain AutoCAD commands and therefore should not be used. Consult AVEVA P&ID technical support for guidance on this subject. Ensure that all nozzles are associated with equipment items.

• Equipment items should be used for the purpose intended, or pipe source and destination information will be lost during the AVEVA P&ID load.

• Where appropriate Process Links should be used instead of pipes for the case where a branch does not need to be labelled, or a connection to an off-line instrument is required.

• Colours: (these comments are subject to whatever project configuration has been setup) • If the project has configured in-line items to be the same colour as the pipe then

items which are not the same colour as the pipe they are associated with have been incorrectly inserted.

• Line fittings should be the same colour as the pipe they were inserted into. If they are not, the symbol has not been inserted correctly the first time or was created on that P&ID.

• Do not place symbols between start and end nodes, or they will not appear in a pipe for any subsequent export of data.

• Process links can be created in any available pipe style defined for the project. Take care to ensure that only branches that are not being labelled are created using the Process Link command or toolbar button.

• Avoid cross associated labels between pipes, i.e. place the label on the pipe which possesses the associated start and end nodes. Use the Show Associations between Items procedure to determine the association.

• Always use destination text if a pipe does not end at a symbol, e.g. if it is expelling steam to the atmosphere or connected to a package item.

12.13:1© 2011 AVEVA Solutions Ltd

Page 236: aveva p&id

AVEVA P&ID 12.1 User GuidePrinciples and Concepts

• Prepare drawing borders at the start of a project in the required drawing sizes and initialize AVEVA P&ID on them, so that when new drawing are created the application will start-up automatically.

• Always be aware of the sequencing in the pipe labels, especially when adding reducers.

• Drawing numbers and pipe flag labels should not have spaces in them.

3.2 Templates AutoCAD templates are basic drawings that provide project standard layouts and styles of drawings, for example drawing sizes, layers, title blocks, borders etc, on which project drawings can be based.

Create the required templates and load the AVEVA P&ID menu into each one. Other users can then copy and open these templates, and start AVEVA P&ID from the attached AVEVA menu. Any changes to network file locking or running untested applications (normally written in C) or LISP routines is not advised. Subsequent problems are unlikely to be supported by the AVEVA P&ID support hotline.

3.3 Automatic Drawing Configuration When AVEVA P&ID is opened for a drawing, AVEVA P&ID compares the current project configuration with the drawing configuration. If differences are found, the drawing is automatically revised to suit.

For details see Project Configuration - 2.2: Project Options Overview.

3.4 Pipes and Symbols

3.4.1 Categories

• Pipes AVEVA P&ID supports an unlimited number of project defined pipe styles. The product ships with defaults of Main, Subsidiary and Process Link defined. On the Pipe toolbar the pipe style can be selected independent of the create pipe or link option buttons. This means that both pipes and links can be created using any of the pipe styles. Users must ensure that any branches that need labelling are created with the Create Pipe option.

• Symbols All symbols consist of AutoCAD blocks, and the available categories are:

• Valves • Equipment • Electrical equipment • Line fittings • Instrument valves (control valves) • Instruments (balloons) • Flow elements • Nozzles

12.13:2© 2011 AVEVA Solutions Ltd

Page 237: aveva p&id

AVEVA P&ID 12.1 User GuidePrinciples and Concepts

• Miscellaneous • Assemblies Non-AVEVA P&ID blocks

3.4.2 Pipe CreationNote: For projects developed using versions of AVEVA P&ID older than AVEVA VPE P&ID

7.2 SP3, an upgrade of the pipes on the project drawings is required. See 2.1: Upgrading Pipes and Symbols from old Projects.

The main points governing the creation of pipes using the Drawing Pipes procedure are as follows:

• A pipe run can be defined freely as a network with many starts and ends and can be drawn in any pipe style. These multiple origins and destinations are included in the connectivity data transferred to the VPE Workbench and are then available for the line list. A pipe can also be created with off-sheet connectors by selecting the required end style on the pipe toolbar before creating the pipe.

• Branches may be drawn in any pipe style. When a branch is connected to another pipe section a tee point is automatically created. If a branch is deleted, the parent connected pipe automatically remakes itself into one line.

• Trim pipes are usually supplied by a vessel vendor and when labelled, are associated with the vessel. Adding trim is achieved by selecting the vessel and clicking the right mouse button, when a menu is displayed showing the trim options.

• Tracing can be added only to pipes and process links but not to signal lines. By means of appropriate commands, tracing can be added to existing pipes, or automatically included when new pipes are drawn. If tracing is required when a pipe is created a check box exists on the pipe toolbar to enable it.

• Pipelines do not show a two-way flow, but, in such cases, the VPE Workbench line list contains destinations read from connected graphical elements, with an appropriate comment, for example 'bi-directional'.

• To manually break pipelines i.e.: when they cross vessels, use of the AVEVA P&IDsymbol insert facility is required to insert break symbols. The break symbols, for example small crosses, are placed by default on the non-plotting layer, but are visible on the screen.

• Where the flow line does not receive a line number, for example, a pressure indicator connected to a pipe or equipment item, process links are used to establish connections between instruments and process items. Where the connecting line is not a signal line, process links are also used for instrument-to-instrument connections. Process links can be drawn in any project defined line style. When data is transferred to VPE Workbench, AVEVA P&ID determines pipe, equipment or instrument owners for connected instruments.

• Pipes when created can be automatically labelled by selecting the auto label pipes checkbox on the label toolbar. When a pipe's graphical route is completed, and the prompt for a new or branch pipe is answered pipe start and end nodes are placed automatically and the label Properties dialog is displayed to define the label.

• Branches can be added to an existing labelled pipe by selecting the pipe label and clicking the right mouse button to display a menu that shows the Add Branch option.

• A default set of signal lines is provided. The set is to ISA standards and consists of signal lines for electrical, pneumatic, hydraulic, electromagnetic, sonic, unidentified signals, and for capillary tubes.

12.13:3© 2011 AVEVA Solutions Ltd

Page 238: aveva p&id

AVEVA P&ID 12.1 User GuidePrinciples and Concepts

3.4.3 Inserting SymbolsNote: For projects developed using versions of AVEVA P&ID older than AVEVA VPE P&ID

7.2 SP3, an upgrade of the symbols on the project drawings is required. See 2.1: Upgrading Pipes and Symbols from old Projects.

Items can be placed on a AVEVA P&ID drawing either by selecting and inserting the required item from Symbol Explorer or from the AVEVA P&ID Tool Palette. See the 8.4.1: Inserting Symbols - General Information procedure for further details.

Every graphical item on a P&ID or flow diagram is classified by a AVEVA P&ID TYPE reference. For example, VLV - Pipe valve. See the 9.3: AVEVA P&ID Item Types and Label Types topic for details. The type reference is assigned automatically on insertion, provided that the symbol is listed in the Symbols Configuration Category of the AVEVA P&ID Project Administration program. The type reference is vital because it allows all AVEVA P&IDcommands to recognize each symbol, and to react accordingly.

Alternatively symbols can be inserted by using Copy and Paste by selecting the required symbol in the drawing, and clicking the right mouse button, where the options will be seen on the menu. This can also be achieved by the use of shortcut keys CTRL-C for copy, and CTRL-V for paste. In-line fittings when pasted into a drawing must be pasted over a flow line where they will insert into the line.

The Insert key on the keyboard opens the Symbol Explorer.

3.5 Validation When drawing a P&ID, two forms of validation must be considered:

• Online (label data) validation, which takes place when P&ID graphics are labelled.

See Drawing P&IDs - 6.13: Label Validation. • Drawing integrity validation, which takes place when the synchronising procedure is

carried out (see 8.8.5: Synchronising Data with a VPE Workbench Database or 8.8.2: Exporting Data to a P&ID Reports Database). This procedure can be used either to validate the data or to both validate and transfer the data to another application such as VPE Workbench.. See also 7.5: Exporting Data to a VPE Workbench Database.

The List Item Details procedure is another validation tool. It can be used to identify the item type of an object and confirm the sequence ID of labels in a pipe.

12.13:4© 2011 AVEVA Solutions Ltd

Page 239: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4 The Graphical User Interface

4.1 Explorer Display OptionsThe AVEVA P&ID graphical user interface includes two Explorers - the Engineering Explorer and the Symbol Explorer. Each is displayed on a tab in the AVEVA P&ID Explorer pane.

The Explorer pane may be displayed in two modes: docking and floating. The docking version may be dragged and "docked" to any edge of the drawing window or may be positioned anywhere within the drawing window. The floating version is designed to be used primarily on dual screen monitors, as it can be dragged to any position on the screen (or screens), not just within the drawing window, so that is does not obscure any part of a drawing.

Docked - Engineering Explorer displayed:

12.14:1© 2011 AVEVA Solutions Ltd

Page 240: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Floating - Symbol Explorer displayed:

The default starting position and mode of the Explorer pane is docked on the left-hand edge of the drawing page, although this may be changed by editing the user's start-up routine (see 2.9: Customisation Guide). When a user initializes a session, it is displayed in the position and mode it was in when the user’s previous session ended.

Continue at:

4.2: Engineering Explorer

4.3: Symbol Explorer

12.14:2© 2011 AVEVA Solutions Ltd

Page 241: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.2 Engineering Explorer • Introduction • Equipment, Instrument and Pipes • Unassigned Items • Context Sensitive Menus • Searching for Items

4.2.1 Introduction The Engineering Explorer provides a hierarchical view of items within the currently open drawings. Details of all open drawings within the current project can be displayed simultaneously. Deleting, adding or modifying an item on a drawing will cause the Engineering Explorer to update accordingly.

You can control the amount of information displayed in the explorer by expanding and contracting the levels using the +/- boxes at the left of each list item.

If an item is selected on the drawings, it is automatically selected in the Engineering Explorer as well.

The Engineering Explorer may be displayed in two modes: docking and floating. For further details, refer to 4.1: Explorer Display Options.

12.14:3© 2011 AVEVA Solutions Ltd

Page 242: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.2.2 Equipment, Instrument and Pipes For each drawing, items are grouped under one of three headings: Equipment, Instrument Loop and Pipes.

• The Equipment heading groups together all equipment items. Equipment items can in turn be collections of items, and this is represented in the Engineering Explorer that displays the hierarchy of items within an equipment collection. The nozzles, trim, trim branches, electrical equipment associated with a top-level equipment item are displayed.

• Under the Instrument Loops heading is a list of the instrument loops on the drawing. Instruments are listed under the appropriate loop node. Instruments that are not in a loop are grouped under a node called "UNNAMED". Instruments can be assigned to loops by dragging and dropping between loop nodes.

• The Pipes heading groups together all the pipes on the drawing, plus the hierarchy of all the branches of each pipe. Inline piping components are not currently represented. Note that pipes will not be displayed in the Engineering Explorer until they have been labelled.

• The part of the pipe that has been labelled as the "main" pipe label is displayed at the top of the hierarchy of a pipe and its branches (see 4.7: The Drawing Page for details). If no main pipe label has been set, the pipe start node properties assume this position by default.

12.14:4© 2011 AVEVA Solutions Ltd

Page 243: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Under the Pipes heading, beneath the list if pipes, pipe groups may be specified for reporting purposes (see 8.6.16: Creating Pipe Groups). Pipes may be assigned to these groups by dragging them from the list of pipes dropping them into the appropriate group.

• Where the label or tag of an item is displayed in red, this indicates that the item is invalid in some way. This occurs when the label of the item has not been sufficiently completed, or in the case of nozzles, not labelled at all.

• The labels of typical items may also be displayed in distinct colours, as specified in the project settings. For example, typical instrument labels may be set to be green in colour. This colour is used for the label both on the drawing, and in the Explorer.

12.14:5© 2011 AVEVA Solutions Ltd

Page 244: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.2.3 Unassigned Items Beneath the drawing nodes, an Unassigned node may be displayed:

• Whether or not this node is displayed is controlled by an option on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

• Beneath this node are listed items in the VPE Workbench database that have not yet been placed on a project P&ID.

• The list is divided into Equipment and Instruments. Items in the Equipment list are sub-divided by discipline (Electrical, Mechanical and Process), then by item type. Items in the Instruments list are sub-divided by item type only (as they are all of the Instruments discipline).

• The list of unassigned items is extracted from the VPE Workbench database when a connection to the database is established (see 8.8.7: Connecting to a VPE Workbench Database). After this has taken place, the connection may be discontinued, and the list derived from a snapshot of the database stored in an XML file.

• Once an item is placed on a project drawing, it is automatically removed from the Unassigned list, and moved to the appropriate position on the drawing item hierarchy as described above.

4.2.4 Context Sensitive Menus When selected, items and folders in the Engineering Explorer have shortcut (right-button) menus.

12.14:6© 2011 AVEVA Solutions Ltd

Page 245: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Drawing Menus • Every menu includes a Sort option that sorts all the engineering items displayed in the

Engineering Explorer according to their labels. • All menus except the top-level Equipment, Instrument and Pipes menus include a

Refresh option which regenerates the Explorer hierarchy. • The Project menu includes options to open new and existing project drawings, and to

connect and disconnect to and from a VPE Workbench project database. • The VPE Login and Logout options are also available on the Drawing menu (see 8.8.7:

Connecting to a VPE Workbench Database and 8.8.8: Disconnecting from a VPE Workbench Database). In addition, this menu includes options to close the drawing, to save it (this options opens a Save Drawing As dialog), to print it, and to synchronise drawing data with data in an external database (VPE Workbench or SQL), assuming that a connection has been established (see 8.8.5: Synchronising Data with a VPE Workbench Database).

• The Drawing menu also includes Close, Save, Synchronise, Print, VPE Logon, VPE Logoff and Insert Symbol options.

• The Synchronise option is used to validate and export data on the drawing to VPE Workbench (see 8.8.5: Synchronising Data with a VPE Workbench Database). The VPE Logon and VPE Logoff options are used to connect and disconnect from the VPE Workbench database (see 8.8.7: Connecting to a VPE Workbench Database and 8.8.8: Disconnecting from a VPE Workbench Database).

• The Insert Symbol option opens the Symbol Explorer, from which the required symbol can then be inserted (see 8.4.1: Inserting Symbols - General Information).

• The Drawing menu and all the menus for engineering items include a Properties option. This option opens the Properties dialog for the selected item, which can be used to enter the labels and other details of the drawing or item. See 4.8: Properties Dialogs.

• Every engineering item menu has four common options: Find, Move, Copy and Delete. When the Find option is selected, the selected item will be zoomed to on the drawing. If the drawing display does not currently show the item (i.e. if the item is not within the current drawing view window, the drawing view window will change accordingly.

• The Move, Copy and Delete options can be used to perform these actions on individual items, or on collections of items. For example, these options can be used to move,

12.14:7© 2011 AVEVA Solutions Ltd

Page 246: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

copy or delete a single branch, or an entire pipe collection including of the branches of the pipe.

• The Instrument Loop node menu includes a New Loop options, used to create new instrument loops. See 8.6.11: Creating Instrument Loops.

• The Pipes node menu includes a New Group option, used to create new pipe groups. See 8.6.16: Creating Pipe Groups.

• Unassigned Menus • Every menu includes a Refresh option that is used to refresh the list of unassigned

items with any changes that have been made to the database (if a connection is present) and to update the list with any drawing changes that it is not yet reflecting.

• The item menus also include Insert and Properties options. The Insert option is used to add items to the current drawing (see 8.4.1: Inserting Symbols - General Information).

• The Properties option opens the Properties dialog for the selected item, on which the details of the item can be viewed. See 4.8: Properties Dialogs. While an item is unassigned, no changes may be made to these details except to assign a Symbol Name, if that has not yet been recorded for the item in the database.

4.2.5 Searching for Items

• To search for items, select this button: . • The Search pane is then displayed:

• Enter all or part of the item tag in the Find What field. Press Enter and select the Find button. The first item that matches the search criteria is then highlighted in the Engineering Explorer and on the drawing. Select the button again to find additional matches.

• As the search criteria are being typed in, items with tags that start with characters entered so far are automatically listed below the field.

• Note that when search for a nozzle, a concatenation of tag of the owning equipment followed by the nozzle number must be entered in the Find What field.

• To select an item from the list, scroll to it using the up and down keyboard buttons and press Enter.

• Press the button again to close the Search pane.

12.14:8© 2011 AVEVA Solutions Ltd

Page 247: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.3 Symbol Explorer

4.3.1 IntroductionThe Symbol Explorer is used to select symbols and place them on a drawing. It is also used to access the Symbol Editor, used to create and edit symbols, and to upgrade existing symbols by adding ports to them.

The Symbol Explorer may be displayed in two modes: docking and floating. For further details, refer to 4.1: Explorer Display Options

12.14:9© 2011 AVEVA Solutions Ltd

Page 248: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.3.2 Using the Symbol Explorer • The top section of the pane displays lists of both Project and Standard groups of

symbols, for example valves or nozzles. If a group of symbols is selected, the content of the group is displayed in the section below.

• The content of a group may be displayed either as icons (below top) or as details (below bottom).

12.14:10© 2011 AVEVA Solutions Ltd

Page 249: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Select the required format from this drop-down menu:

• When the pane is in Icons view mode, details of the currently selected symbol are displayed below the symbol icons. When the pane is in Details view mode, a preview image of the selected symbol is displayed below the symbol details.

12.14:11© 2011 AVEVA Solutions Ltd

Page 250: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• To refresh the images of symbols, for example if a symbol has been edited or a new symbol has been created using the Symbol Editor (see below), right-click and select the Refresh option.

• To search for a symbol, select this button:

The Symbol Search pane is then displayed:

Enter all or part of the symbol name in the Find What field, and select either Symbol Name or Symbol Description from the Find In field. Press Enter. The first symbol that matches the search criteria is then highlighted in the Symbol Explorer. Select the button again to find additional matches.

As the search criteria are being typed in, symbols descriptions that start with characters entered so far are automatically listed below the field. For example, if "GAT" is typed, "Gate Valve" will be listed, plus any other symbol descriptions that start with "GAT".

To select a symbol description from the list, scroll to it using the up and down keyboard buttons and press Enter. The mouse cannot be used for this due to an AutoCAD limitation.

Select the button again to close the Symbol Search pane. • Once the required symbol has been selected it may be inserted by right-clicking on it,

and selecting the Insert option, by double-clicking on it, or by dragging and dropping it from the Symbol Explorer onto the drawing page. See 8.4.1: Inserting Symbols - General Information.

• Symbols may also be inserted as "unintelligent" AutoCAD blocks, instead of as intelligent VPE symbols, by right-clicking on the symbol in question and selecting Insert Block.

• When assemblies are created (see 8.9.1: Creating Assemblies), they are automatically placed in the Assemblies sub-folder of the Project folder.

12.14:12© 2011 AVEVA Solutions Ltd

Page 251: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• When symbols are exported from a drawing (see 8.8.19: Exporting Symbols), they are automatically placed in the ExportSymbols sub-folder of the Project folder.

• Creating and Editing SymbolsSymbols are created and edited using the Symbol Editor, which is accessed from the Create Symbol and Edit Symbol right-click menu options. Before the Symbol Editor is accessed, the user must login as a Project Administrator (using the same password used to access the AVEVA P&ID Project Administration Program), by selecting the Admin Login menu option (the Admin Login option is replaced by Admin Logout if the user has already logged in).

Click here for details of the Symbol Editor.

• Upgrading SymbolsThe Symbol Explorer includes a facility to upgrade existing symbols by adding ports to them.

Note: This procedure must be carried out to upgrade all symbols on project drawings to AVEVA VPE P&ID 7.2 SP3 or AVEVA P&ID 12.0 or later standard.

To upgrade symbols, right-click on the Symbol Explorer and select the Upgrade Ports option from the menu that is then displayed. Each project symbol is then upgraded in turn.

Note: Only the symbol files located in the \PMETSYM (Metric projects) or \PIMPSYM (Imperial projects) symbol folders, or in sub-folders in these folders, are included in the upgrade.

A log file is created in the project symbol folder that contains lists the symbols that were correctly upgraded, any errors that occurred, and warnings that single connection symbols were upgraded (and therefore should be checked). For example:

[C:\Aveva\P&ID\PROJECT\IPE\Autocad\Pmetsym\NV.DWG] [VLV] successfully upgraded Error: Symbol not found in project area [WEVA] Warning: Symbol with single insertion point [C:\Aveva\P&ID\PROJECT\IPE\Autocad\Pmetsym\Line Fittings\FLAG2.DWG] [PFL]

The log files are best viewed in WordPad.

Note: If single connection symbols are included in the upgrade, it is recommended that they are checked afterwards to ensure that ports have been placed on the correct sides of the symbols. It is not always possible for the upgrade routine to detect which this is.

Note: After the upgrade process is complete it is recommended that before using the upgrade symbols they are inspected using the Symbol Editor, to check that the ports have been added correctly.

Ports can also be added to symbols manually, using the Symbol Editor.

12.14:13© 2011 AVEVA Solutions Ltd

Page 252: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.4 Symbol EditorNew project symbols can be created, and existing symbol edited using the Symbol Editor.

New symbols can be created using the Symbol Editor by:• Drawing an entirely new symbol• Selecting an existing symbol from a symbol library and editing it• Selecting entities on a drawing, either "dumb" AutoCAD blocks or "intelligent" AVEVA

P&ID symbols, and editing them

4.4.1 Logging OnBefore the Symbol Editor can be accessed, the user must login to the Administrator. Right-click on a symbol in the Symbol Explorer and select Admin Login from the menu that is then displayed. The Login dialog is then displayed. Enter the required login details (see the AVEVA P&ID Project Administration Program).

To logout, right-click and select the Admin Logout option instead (the Login option is replaced by this when the user has logged in).

4.4.2 Accessing the Symbol EditorThe Symbol Editor can then be accessed by:

• right-clicking on a symbol in the Symbol Explorer and selecting either the Create Symbol or Edit Symbol option from the menu that is then displayed, or

• selecting the Create Symbol option from The Drawing Page shortcut menus or the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Symbol Editor then opens within the AVEVA P&ID window.

Note that only one symbol can be created or edited at a time.

If the Edit Symbol option was selected, the symbol right-clicked on in the Symbol Explorer is opened for editing in the Symbol Editor.

12.14:14© 2011 AVEVA Solutions Ltd

Page 253: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.4.3 New Symbol OptionsIf the Create Symbol option was selected, the following file dialog box is then displayed:

• If a new symbol definition is to be created and added to the project, select the New option. Enter the name of the new symbol in the Symbol Name field. Select a P&ID type and enter a description in the PID Type and Symbol Description fields. Browse for the location for the new symbol file via the button adjacent to the File/Directory path field.

Note: In the case of pipe flags (off-sheet connectors), the symbol name must end with either -IN or -OUT depending on whether the flag symbol is intended to represent a connector into drawings or out of drawings.

• If an existing symbol definition is to be added to the project, one that has already been drawn, perhaps in another project, press the Existing button. Then browse for the appropriate symbol drawing file using the button adjacent to the File/Directory path field. Select a P&ID type and enter a description in the PID Type and Symbol Description fields.

• If a symbol is being created from entities on the drawing, select the From Drawing option.

Note: If the dialog was accessed from the drawing page menu option, only this option is available.

Enter the name of the new symbol in the Symbol Name field. Select a P&ID type and enter a description in the PID Type and Symbol Description fields. Browse for the location for the new symbol file via the button adjacent to the File/Directory path field. • If the dialog was opened from the Symbol Explorer, or was accessed from drawing

page shortcut menu with nothing selecting on the drawing, the entities on the drawing that are to form the basis of the new symbol must be selected on the drawing.

• If the dialog was opened from drawing page shortcut menu with an entity selected, this is not required. The selected entity or entities will form the basis of the new symbol.

12.14:15© 2011 AVEVA Solutions Ltd

Page 254: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Note: When a symbol is created by selecting entities from a drawing, make sure that AutoCAD limits are checked, to ensure that the graphical components of the symbol are within the drawing limits before the base point is set.

The command to check and change drawing limits is “Limits”.• When all details of the symbol have been entered, press OK. The dialog box will be

closed and the Symbol Editor will open. New symbols can now be drawn using the Symbol Editor, and Existing symbols or drawing entities edited to create the new symbol.

4.4.4 Using the Symbol EditorThe Symbol Editor is an AutoCAD based application. Symbols are drawn and edited using standard AutoCAD and AVEVA P&ID drawing facilities. Additional controls are provided to enable the user to create valid AVEVA P&ID symbols, such as port valves (see below).

• Adding Insertion PointsEvery AVEVA P&ID symbol must have an insertion point. This is specified in the Symbol Editor by right-clicking and selecting the Set Base Point option from the menu that is then displayed.

Select the insertion point by clicking on the required point on the symbol. The insertion point is marked with a yellow circle.

12.14:16© 2011 AVEVA Solutions Ltd

Page 255: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Adding Ports to SymbolsTo add ports to a symbol, right-click on it and select the Insert Port option from the menu that is then displayed, and then place the ports at the required positions.

Once all the ports have been placed, they may be named. Select the Edit Port Identities option from the right-click menu. The following dialog is then displayed:

As required, in the Port ID fields enter the identifiers of each port. Port identifiers can be alpha or numeric, or any combination, but must be unique on the valve.

These IDs will be displayed for these ports on the Properties dialogs used to label port valves of the current type, and will be exported to VPE Workbench as the port identifiers, and appear on datasheets as appropriate.

• Adding User Defined Attributes To add user defined attributes to symbols:

1. Select the symbol in question and open the Symbol Editor as described above.

12.14:17© 2011 AVEVA Solutions Ltd

Page 256: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

2. Enter the ATTDEF command at the command line. The Attribute Definition dialog is then displayed.

3. Check the Preset checkbox. Check the other checkboxes, e.g. the Invisible checkbox as required. Refer to AutoCAD documentation for guidance.

4. Enter the name of the attribute in the Tag field.5. Enter the default value of the attribute in the Default field.6. Press the OK button. The dialog then closes.7. Unless the insertion point of the new attribute was specified in the dialog, the following

prompt will then be displayed: "Specify start point:”. Specify the insertion point of the attribute in the main Symbol Editor window, i.e. where the attribute value is to be displayed relative to the symbol when the symbol is labelled.

Once defined for a symbol type, user-defined attribute values can be entered using the AVEVA P&ID Properties dialogs (see 4.8: Properties Dialogs). They will be grouped under a node called User Defined Attributes.

12.14:18© 2011 AVEVA Solutions Ltd

Page 257: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Note: If a new attribute has been defined for a symbol of a type which already has labelled instances on a drawing, to add the new attribute to the labels of these symbols, enter UDAS at the command line, and select one of the symbols on the drawing. All the symbols of that type will then labelled with default value of the new attribute.

To update all project drawings or selected project drawings with new or changed attributes, use the Refresh UDAs utility (see below).

To remove all such UDAs from selected symbols on a drawing, see 8.6.34: Removing UDAs from Symbols.

• Accessing the Dynamic Block EditorSymbols may be made into dynamic blocks by using the AutoCAD Block Editor. This is accessed from the Symbol Editor by selecting the Dynamic Block Editor option from the right-click menu.

See AutoCAD documentation for details of the Block Editor.

4.4.5 Closing the Symbol Editor and Updating the Drawing Symbol LibraryTo close the Symbol Editor and save any changes made to the symbol being edited, select the Done option from the right-click menu.

To load a new symbol into the drawing symbol library, select the Refresh Settings option in the AVEVA P&ID Group of the Home Tab.

12.14:19© 2011 AVEVA Solutions Ltd

Page 258: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

The following message is then displayed:

Click Yes to continue.

12.14:20© 2011 AVEVA Solutions Ltd

Page 259: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.5 P&ID Data Grid

4.5.1 OverviewThe P&ID Data Grid is used to display details of project equipment, pipes, instruments nozzles, valves, line fittings and unassigned sheet connectors in tabular form.

It can also be used to:• Assign unassigned items (created in P&ID Reports) to drawings• Assign source/destination drawing sheets to off-page connectors• Transfer instruments from AVEVA Instrumentation and add them to drawings.• Transfer electrical equipment from AVEVA Electrical and add them to drawings.• Transfer data to and view PDMS Schematic databases.• Label drawings with any of the data displayed in the tables.

Note that the P&ID Data Grid only displays details of drawing data that has been Synchronised (see 8.8.5: Synchronising Data with a VPE Workbench Database).

To open the P&ID Data Grid, select the Load P&ID Grid option in the P&ID Reports Groupof the Data Management Tab.. The P&ID Data Grid opens by default below the drawing window.

To close the P&ID Data Grid, click the x button in the top-left corner.

The P&ID Data Grid consists of two main windows. The left-hand window of the P&ID Data Grid includes hierarchical tree-view of project items, similar to that of the Engineering Explorer.

It includes Unassigned and Assigned nodes under the AVEVA P&ID Database node. The Assigned node lists items in the database that are on a project drawing. The Unassigned node lists items, created in P&ID Reports, which have not been added to a project drawing, and sheet connectors on project drawings which have no source or destination drawing sheet defined for them.

The tree-view also lists of assigned and unassigned instruments from AVEVA Instrumentation and of assigned and unassigned electrical equipment from AVEVA Electrical, and lists of items in the connected PDMS Schematic database.

12.14:21© 2011 AVEVA Solutions Ltd

Page 260: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

The tree view is used to select an item or category of item, the details of which are in displayed in a grid in the right-hand window.

This is used to select an item or category of item, the details of which are in displayed in a grid in the right-hand window.

Note that the layout of the data as displayed in the right-hand section may be configured. Columns may be added, removed, re-ordered, filtered and pinned, and data may be grouped the values in selected columns. See below for details.

Above the windows, a number of buttons are displayed. These are used to configure the display of data in the right-hand window, zoom into a selected item on the drawing, refresh labels on the drawing inserted from the P&ID Data Grid, and to export the data displayed in the right-hand windows to an Excel spreadsheet.

Continue at:• 4.5.2: Viewing P&ID Drawing Data• 4.5.3: Assigning Unassigned Items to a Drawing• 4.5.4: Assigning Sources/Destinations to Page Connectors• 4.5.5: Viewing and Assigning AVEVA Instrumentation and AVEVA Electrical Data• 4.5.6: Viewing and Exporting to a PDMS Schematic Database• 4.5.7: Zooming into an item on the Drawing• 4.5.8: Labelling the Drawing with Data from the P&ID Data Grid

12.14:22© 2011 AVEVA Solutions Ltd

Page 261: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• 4.5.9: Configuring the Grid Layout• 4.5.10: Exporting the Grid to an Excel Spreadsheet• 4.5.11: Viewing Item Datasheets

4.5.2 Viewing P&ID Drawing DataThe P&ID Data Grid can display data either from the current drawing only, or from all project drawings.

To view details of assigned items, i.e. items on a project drawing, select the Assigned node. If only data from the current drawings is to be displayed, select the Current Drawing Data option from the Drawing Selection field list. If data from all project drawings is to be displayed, select the Project Data option.

To view details of unassigned items, i.e. items which were created in P&ID Reports and on not yet assigned to a project drawing, select the Unassigned node.

To view details of all items in a category of item, for example all instruments, select the appropriate node under the AVEVA P&ID Database node in the left-hand window.

To view details of a single item, expand the item category node and select the item in question from the list of items under that node.

Details of the selected item or items are then displayed in the grid in the right-hand window.

Facilities are provided to assign a selected unassigned item to the current drawing. See 4.5.3: Assigning Unassigned Items to a Drawing.

Located under the Unassigned node, the Unassigned Page Connectors node is used to view lists of sheet connectors which have no source or destination drawing sheet defined for them. These nodes can be used to assign source or destination sheets to unassigned connectors (see 4.5.4: Assigning Sources/Destinations to Page Connectors).

4.5.3 Assigning Unassigned Items to a DrawingThe Equipment, Instruments and Pipes nodes under the Unassigned node of the AVEVA P&ID Database node is used to view items in the project database that have not been added to a project drawing. Such items are created in P&ID Reports (refer to AVEVA P&ID Reports documentation for details). They may be added to a drawing by the facilities provided by the P&ID Data Grid.

For details of the procedure for adding unassigned items to a drawing, see 8.4.12: Inserting Unassigned P&ID Database Symbols and 8.5.2: Inserting Unassigned P&ID Database Pipes.

12.14:23© 2011 AVEVA Solutions Ltd

Page 262: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.5.4 Assigning Sources/Destinations to Page ConnectorsThe Unassigned Page Connectors node under the Unassigned node of the AVEVA P&ID Database node is used to view lists of all the sheet connectors on project drawings which have no source or destination drawing sheet defined for them. There are separate lists for off-sheet and on-sheet connectors. .

These nodes can be used to create connection between these unassigned connectors, and a new or existing connector on the current drawing. See 8.6.18: Labelling and Connecting Pipe Flags for details.

4.5.5 Viewing and Assigning AVEVA Instrumentation and AVEVA Electrical DataBefore AVEVA Instrumentation or AVEVA Electrical data can be viewed, the appropriate AVEVA Instrumentation or AVEVA Electrical project must first be logged onto to.

Right-click on the AVEVA Instrumentation or AVEVA Electrical node and select the Login option from the menu that is then displayed.

Note: Whether or not these nodes are displayed is controlled on the AI Integration Configuration Category and the AE Integration Configuration Category of the AVEVA P&ID Project Administration program.

From the dialog that is then displayed, click on the required project, and press the Select button.

12.14:24© 2011 AVEVA Solutions Ltd

Page 263: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

If an AVEVA Instrumentation project is selected, details of the instruments in the AVEVA Instrumentation project are then listed under the Unassigned Instruments and Assigned Instruments nodes. The Assigned Instruments node lists those instruments that have been added to a P&ID project drawing. The Unassigned Instruments node lists those that have not.

If an AVEVA Electrical project is selected, details of the electrical equipment in the AVEVA Electrical project are then listed under the Unassigned Electrical Equipment and Assigned Electrical Equipment nodes. The Assigned Electrical Equipment node lists the equipment that has been added to a P&ID project drawing. The Unassigned Electrical Equipment node lists those that have not.

Beneath each of these nodes is a node for each type of item. If one these nodes is selected, details of the item of the selected type are displayed in the grid in the right-hand window.

For the procedure for assigning AVEVA Instrumentation instruments and AVEVA Electrical equipment, see 8.8.12: Transferring Data from AVEVA Instrumentation and AVEVA Electrical.

To view additional properties of an instrument or the loop it is assigned to, right-click and select the Show Instrument Detail or the Shop Loop Detail option.

To view additional properties of electrical equipment, right-click and select the Show Equipment Detail.

12.14:25© 2011 AVEVA Solutions Ltd

Page 264: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

A dialog will then be opened that will display all details of the instrument, loop or electrical equipment.

Refer to AVEVA Instrumentation and AVEVA Electrical documentation for details of these dialogs.

4.5.6 Viewing and Exporting to a PDMS Schematic DatabaseBefore PDMS Schematic data can be viewed, the appropriate PDMS Schematic database must first be logged onto to.

Right-click on the AVEVA Schematic Database node and select the Login option from the menu that is then displayed.

Note: Whether or not this node is displayed is controlled on the PDMS Integration Configuration Category of the AVEVA P&ID Project Administration program.

The PDMS Login dialog is then displayed.

12.14:26© 2011 AVEVA Solutions Ltd

Page 265: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Enter the appropriate login details for the Schematic database project and database, and press the OK button.

Note: Default entries for the Project and MDB fields are set in the PDMS Integration Configuration Category.

Right-click on the AVEVA Schematic Database node and select the Get Work option from the menu that is then displayed.

Details of the offline instruments, inline instruments, equipment and pipes in the selected database are then listed under the AVEVA Schematic Database node.

If the Current Drawing Option is selected, only items exported to the database from the current drawing are displayed. If the Project Data option is selected, items exported from all project drawings are displayed.

12.14:27© 2011 AVEVA Solutions Ltd

Page 266: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

To view details of all items in a category of item, for example all offline instruments, select the appropriate node under the AVEVA Schematic Database node in the left-hand window.

To view details of a single item, expand the item category node and select the item in question from the list of items under that node.

To connect to a different database, right-click on the AVEVA Schematic Database node and select the Login option again.

To export data to the Schematic database, right-click on the AVEVA Schematic Database node and select the Save Work option. Refer to 8.8.13: Transferring Data to PDMS Schematic Databases for details.

4.5.7 Zooming into an item on the DrawingTo select an item on the drawing and zoom into it, select the item in the grid and either right-click and select the Zoom-In option from the menu that is then displayed, or select this

button from the area above the grid: .

4.5.8 Labelling the Drawing with Data from the P&ID Data GridAll of the data displayed in the tables in the right-hand window of the P&ID Data Grid may be used to label the drawing. In this way, the drawing may be labelled with data not available using the normal labelling procedures, i.e. with properties of items that are not included in the standard labels.

For details of this procedure see 8.6.22: Labelling with Data from the P&ID Data Grid.

See also 8.6.23: Refreshing P&ID Data Grid Labels.

4.5.9 Configuring the Grid Layout• Adding, Removing and Re-Ordering Columns• Grouping Data• Filtering Data• Fixing Column Headings

• Adding, Removing and Re-Ordering ColumnsThe order in which columns are displayed from left to right can be changed. To change the position of a column, drag and drop the column heading to the required position.

The width of columns may also be changed. Place the cursor at the edge of a column heading, hold down the left-mouse button and drag it out or in to the required width.

12.14:28© 2011 AVEVA Solutions Ltd

Page 267: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

To add or remove columns, and to change the default order that columns are displayed in from left to right, open the grid to be configured, and select this button from the area above

the grid: .

The Grid Column Settings dialog is then displayed:

The Select Type field lists each of the grids, for example the grid displaying instrument details (INSTLIST). By default, the grid displayed when the dialog was accessed is displayed. Select another grid type if required.

The Column Name fields list all the data columns that may be displayed in the selected grid. To include a column in the display, check the adjacent Visibility checkbox. To remove it, uncheck the checkbox.

To change the default order in which columns are displayed, select a column from the list and press the up or down arrow button as appropriate. Multiple columns can be selected and moved.

Select the Apply button to save the changes without closing the dialog.

Select the OK button to save the changes and close the dialog.

12.14:29© 2011 AVEVA Solutions Ltd

Page 268: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Select the Cancel button to close the dialog without saving the changes.

• Grouping DataThe format of the display of items can be changed so that records with attribute values in common are grouped together. For example, item records can be grouped according to their Description or Tag.

To group data, first activate this facility by selecting this button from the area above the grid:

.

The grouping bar is then displayed above the column headings:

To group data, drag and drop the column heading of the attribute in question into the space above the column headings.

The form then changes to display the name of each group in the following format:

<Attribute Name>: <Attribute Value> <(Number of records in the group)>.

The name of the column that records are grouped by is displayed in the grouping bar.

12.14:30© 2011 AVEVA Solutions Ltd

Page 269: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

To view the items within a group, click on the “+” button next to the group name. The items are then listed under the name. Press the “-“ button to close the list.

Note that the fields within a group can be fixed, moved and filtered in the normal way.

- Grouping by Multiple Attributes

Records can be grouped by more than one attribute. For example, by Description and then by Tag. To group by a second attribute, for example Tag, drag and drop the heading of this attribute into the grouping bar.

If the heading of the second attribute (e.g. Tag) is dropped to the right of the first attribute (Description), items will be grouped first by (Description), then by (Tag).

For example, each group of item records with the same Description will be sub-divided into groups of items with the same Tag.

12.14:31© 2011 AVEVA Solutions Ltd

Page 270: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

If the second heading is dropped to the left of the first heading, records will be grouped the other way round.

- Ungrouping Data

To "ungroup" data, drag and drop the column heading or heading from the grouping bar back to the column bar.

To remove the grouping bar, select the button above the grid again.

• Filtering DataThe data displayed in a grid can be filtered so that only items that meet the criteria set in the filter conditions are displayed.

To filter data, first activate this facility by selecting this button from the area above the grid:

.

The filter symbol then appears in the column headings.

To apply a filter, click on the filter symbol in the appropriate column heading. A list of filtering options is then displayed.

If (All) is selected, all records will be displayed (i.e. there is no filtering)

If (Blanks) is selected the filter will restrict the data displayed to those records that do not have a value in the selected column.

If (NonBlanks) is selected the filter will restrict the data displayed to those records that do have a value in the selected column.

If (Custom) is selected, the Enter Filter Criteria dialog will be displayed. This is used to set up more advanced filters (see below).

If a column value is selected from the list, only records that contain that value in the column are displayed.

- Applying a Custom Filter

More complicated filters can be set up using the Enter filter criteria dialog. To access, select the (Custom) option in the list. The Enter filter criteria for [name of field] dialog is then displayed.

Two types of filter conditions can be set up using this dialog, “And” and “Or”. For data to be displayed on a tab, it must either match all of the “And” conditions and at least one of the “Or” conditions.

12.14:32© 2011 AVEVA Solutions Ltd

Page 271: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

To set up a custom filter:

1. In the Operator field, select an operator. In the Operand field, select a value.2. To add a second condition, select the Add a condition button. Another row of fields is

then added to the form in which a filter condition can be entered as described above. Repeat for each required filter condition.

3. Specify whether the conditions are "And" conditions or "Or" conditions by selecting either the And condition or Or condition button.

4. To delete a condition, select it by pressing the button at the beginning of the filter condition row, then press the Delete Condition button.

5. When all the required filter conditions have been set up, press the OK button. The filter will then be applied to the grid.

- Removing Filtering

To remove all filtering from a column, select the (All) option from each of the list of filtering options.

To deactivate filtering, select the button above the grid again.

12.14:33© 2011 AVEVA Solutions Ltd

Page 272: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Fixing Column HeadingsColumns can be fixed. When a column is fixed, it is moved to the left-hand edge of the display, and remains fixed in that position and visible when the grid is scrolled to the right.

To fix columns, first activate this facility by selecting this button from the area above the grid:

.

Pin buttons are then displayed in the column headings.

To fix a column, click on the pin button in the column heading.

The pin button changes to indicate that the column is pinned. The column is moved so that it is the first column on the left. Multiple columns can be pinned at the same time.

To un-pin a column, press the button again. The column is no longer pinned, but will remain in the far-left position.

To remove the pin buttons, select the menu option or the toolbar button again.

4.5.10 Exporting the Grid to an Excel SpreadsheetTo export a grid to an Excel spreadsheet, select this button from the area above the grid:

.

A Save As dialog is then displayed. Specify the name and location of the spreadsheet to be generated.

Press the Save button. The report spreadsheet is then generated.

The data in the spreadsheet will be displayed in the same layout as the grid in currentlyin.

4.5.11 Viewing Item DatasheetsTo view a datasheet for an AVEVA Instrumentation instrument or AVEVA Electrical equipment, right-click on the item in the grid and select the View DataSheet option from the menu that is then displayed.

12.14:34© 2011 AVEVA Solutions Ltd

Page 273: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

The datasheet for the item is then displayed.

A datasheet number must have been assigned to item in AVEVA Instrumentation or AVEVA Electrical. If not, an error message will be displayed.

12.14:35© 2011 AVEVA Solutions Ltd

Page 274: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.6 AVEVA P&ID Tool Palette The AVEVA P&ID Tool Palette is a customised version of the AutoCAD Tool Palette, used to insert intelligent symbols and lines.

See 2.10: Customising the AVEVA P&ID Tool Palette for more details.

12.14:36© 2011 AVEVA Solutions Ltd

Page 275: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.7 The Drawing Page

4.7.1 Viewing Pipe and Inline Item PropertiesThe properties of pipes and items can be viewed on the drawing page by hovering the cursor over the pipe segment or symbol in question. The properties are then displayed as illustrated below.

4.7.2 Drawing Page MenusItems on a drawing page have shortcut menus accessed by right-clicking on the them. The options displayed depend on the item selected. Shortcut menus are also available for the drawing page itself.

12.14:37© 2011 AVEVA Solutions Ltd

Page 276: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

All items on a drawing page have a number of common options:• The Enter and Cancel options are used to complete or abort commands on the

selected item(s). • The Repeat Last Command option is used to repeat the last selected command.• The Copy, Paste, Delete, Rotate and Move options can be used to perform these

actions on individual items, or on collections of items (using these options on the drawing page menu – see below). For example, these options can be used to copy (see 8.7.1: Copying Drawing Objects and Labels), paste, delete (see 8.7.6: Deleting Drawing Objects), rotate (see 8.7.5: Rotating Drawing Objects) or move (see 8.7.2: Moving Drawing Objects) a single item, or a group of items selected using the mouse.

• The Properties option opens the Properties dialog for the selected item, which can be used to enter the labels and other details of the drawing or item. See 4.8: Properties Dialogs.

• The Typicals option is available if the Typical Items facility is enabled at project level, and if the item has been labelled with the minimum mandatory data for the item type. The option provides access to a dialog box for the entry, deletion and modification of the typical data. See 8.6.25: Labelling Typical Items.

• The Create Symbol option is used to access the Symbol Editor.

The menus for pipes, pipe start nodes, trim pipes and so on include the following additional options:

• The Segments... option opens a sub-menu which consists of options for adding, merging, deleting and adding elbows to pipe segments. See 8.5.13: Adding Pipe and Signal Line Segments, 8.5.14: Merging Pipe Segments, 8.5.15: Deleting Pipe and Signal Line Segments) and 8.5.17: Adding Elbows to a Line.

12.14:38© 2011 AVEVA Solutions Ltd

Page 277: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• The Pipes... option opens a sub menu which consists of options for merging pipes, splitting a pipe into two new pipes, splitting a branch off a pipe, and reversing the flow of a pipe. See 8.5.9: Merging Pipes, Branches and Signal Lines, 8.5.10: Splitting Pipes and Signal Lines, 8.5.11: Splitting off Branches and 8.5.12: Reversing Pipe and Signal Line Flows)

• The Extend option is used to change the length of a line (i.e. a pipe, process link or signal line). See 8.5.16: Changing the Length of Lines.

• The Break option is used to manually insert a break in a pipe. See 8.5.8: Breaking Lines.

• The Refresh Pipe Arrows option is used to redraw the pipe arrows (flow direction indicators) of a pipe. This may be required in case the flow direction is changed and the arrows do not immediately re-orientate themselves automatically.

• The Set As Main on - off option is used, in the case of pipes that have multiple labels, to set one of these labels as the “main pipe label”. See 8.6.27: Setting a Pipe Label as the Main Label.

• The Add Label... option is used to place additional labels on a labelled pipe (use the Properties option to enter properties for an unlabelled pipe or to edit an existing pipe label). See Adding Extra Labels to a Labelled Pipe.

The instruments menu also includes the Segments... option and sub-menu. In the case of instruments, only the Add option is used, for use if a pipe segment is to be added to an inline instrument at the end of a pipe. See 8.5.13: Adding Pipe and Signal Line Segments.

The equipment menu include the following additional options:

• The Add Trim Label... option is used to label the trim of a vessel. See Adding a Trim

Label.• The Add Header option is used to add and edit equipment headers. See 8.6.5: Adding

Equipment Headers.

The Pipe Flag menu includes the following additional options:

• The Open Target Drawing... option is used to open the drawing on which the linked pipe flag is located, assuming the connection between the two flags has been hyperlinked.

12.14:39© 2011 AVEVA Solutions Ltd

Page 278: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• The Propagate... option is used to propagate the properties of a pipe to another pipe via connected pipe flags. See Propagating Changes to Pipe Properties.

• The Disconnect... option is used to disconnect linked pipe flags. See Disconnecting Pipe Flags.

The instrument label balloon menu includes the following additional options:

• The Associate Text Option is used as part of the AutoCAD drawing upgrade routine to upgrade AutoCAD text to labels for instruments. See Upgrading Instrument Text.

• The Associate as Label Balloon option is used as part of the AutoCAD drawing upgrade routine to associate an upgraded label balloon to an inline instrument. See Associating Instrument Label Balloons with Inline Instruments.

The pipe label menu includes a Set as Default Label option, used to specify that a specific pipe label is the default label by which a pipe will be identified in the database. See Setting a Pipe Label as the Default Pipe Label.

If multiple items are selected, or if no item is selected on the drawing page, right clicking opens the drawing page menu, which includes the following additional options:

12.14:40© 2011 AVEVA Solutions Ltd

Page 279: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• The various Zoom options and the Aerial View... option are used to change the viewing magnification and area.

• The Regen option refreshes the drawing display. • The Delete Error Blocks option is used to delete error blocks from the drawing after

the errors they highlight have been resolved.• The Ports Display -on and Ports Display -off options are used to turn the display of

valve ports on and off. See 8.3.4: Turning the Display of Ports On and Off.• The Insert Symbol... option opens the Symbol Explorer, from which the required

symbol can be selected for insertion. See 8.4.1: Inserting Symbols - General Information.

• This menu also includes the Copy, Paste, Delete, Rotate and Move options, so that these actions can be carried out on the multiple items selected.

• The Properties option on this menu is used to open the Properties Dialogs for the drawing, in which the title and other general drawing details can be added or edited.

• The Upgrade Utility Commands options are used to upgrade non-intelligent "dumb" AutoCAD pipes, symbols and text to intelligent AVEVA P&ID items and labels. See 5.4: Upgrade Procedures in AVEVA P&ID.

12.14:41© 2011 AVEVA Solutions Ltd

Page 280: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.8 Properties DialogsProperties dialogs are used to add and modify the “intelligence” associated with engineering items, such as the label (tag) and other details. Properties dialogs are also available for entering general details of drawings, and to select default settings relating to drawing and labelling.

There are two types of Properties dialog, modal and non-modal. There is a modal dialog for each type of item for which properties can be viewed and entered. Only one modal dialog can be opened at a time.

There is a single non-modal dialog which displays the details of whichever item is currently selected. Unlike the modal dialog, other dialog can be opened and interacted with while this dialog is open.

4.8.1 Modal Properties Dialogs• Modal Properties dialogs can be accessed in various ways. They can be opened by

selecting an item on the drawing page or the Engineering Explorer, and then selecting the "Properties" options on the shortcut menu for the item. Alternately, activate the labelling command first and then select an item to be labelled. See 8.4.1: Inserting Symbols - General Information.

• The modal Properties dialog for an item may also be displayed automatically when an item is placed on the drawing if "auto-labelling" is on for the category of item. For example, if auto-labelling is on for equipment, immediately after an equipment item is placed, the modal Properties dialog for the equipment opens automatically. Auto-labelling can be switched on and off facilties in the Pipeline Group of the Home Tab.

12.14:42© 2011 AVEVA Solutions Ltd

Page 281: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Modal Properties dialogs consist of two tabs. The Properties tab is used to enter the tag and other essential engineering data for the item.

• It may also be used to change the layer that the item label is located on, and the line type and line type scale of the item symbol.

12.14:43© 2011 AVEVA Solutions Ltd

Page 282: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• The All Properties tab includes fields for entering all data relating to the item, for example additional engineering data and the appearance of the item label, as well as the fields on the Properties tab.

• Fields are grouped under headings into logical categories. The fields within a category can be hidden or revealed by using the +/- boxes at the left of each category heading.

12.14:44© 2011 AVEVA Solutions Ltd

Page 283: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Beneath the fields, tips on how to complete each individual field are displayed as each field is selected. A preview of how the item tag will appear on the P&ID is also displayed, as configured in the AVEVA P&ID Project Administration program.

• Many of the fields on a modal Properties dialog can be completed by selecting from a drop-down list. These lists contain the values that are "allowed" for the particular field. List of values can be accessed by clicking the button at the right-hand side of the field. The lists of values display descriptions of each value.

When typing into a field that has a list of values, this list is displayed automatically after the first character is entered. You may then select the rest of the entry from the list, or continue to type it in. The permissible values comprising such lists are held in the validation files for the project (see 3.5: Validation). If an invalid entry is made, the field will replace the invalid value with a default value from the list.

• The project can be set-up so the last value entered in a Properties dialog field automatically populates that field that next time that Properties dialog is accessed for an unlabelled item of that item type. This is set up using the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program.

• User Defined Attributes (UDAs) may be defined for project items (see 6.12: Adding User-Defined Attributes). The Properties dialogs for these items will include the fields required to enter values for these attributes.

Note: In the rest of this document, modal Properties dialogs are simply referred to as "Properties dialogs".

12.14:45© 2011 AVEVA Solutions Ltd

Page 284: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.8.2 Non-Modal Properties Dialog• The non-modal Properties dialog is opened by select the P&ID Properties option in the

Properties Group of the Home Tab:

• The dialog displays details of whichever item is currently selected on the drawing. If no item is selected, the drawing properties are displayed.

• The non-modal Properties dialog displays all the properties of the item, including UDAs etc, on a single tab.

12.14:46© 2011 AVEVA Solutions Ltd

Page 285: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Note that tags, pipe sizes, instrument types and other validated data cannot be entered or changed using this dialog. A button in each tag field opens the relevant modal Properties dialog, in which the required values must be entered:

The modal dialog will include a field for all the data of the item that cannot be modified in the non-modal dialog.

• Drawings can be labelled from the non-modal dialog by hovering the mouse over the value in the Properties dialog that the drawing is to be labelled with, then moving the cursor over the drawing. The user will then be prompted to pick a point place the label.

12.14:47© 2011 AVEVA Solutions Ltd

Page 286: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.9 AVEVA P&ID TabsThe first three tabs of the AVEVA P&ID ribbon menu consist of AVEVA P&ID specific commands.

See:• Home Tab• Data Management Tab• Utilities Tab

4.9.1 Home Tab

• AVEVA P&ID GroupThe AVEVA P&ID group consists of a single menu:

Project Administrator

Used to open the AVEVA P&ID Project Administrator program. See 2.3: AVEVA P&ID Project Administration Program.

Refresh Settings

Used to update the drawing with the current project settings (see 2.2: Project Options Overview).

12.14:48© 2011 AVEVA Solutions Ltd

Page 287: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

• Modify GroupThe Modify group consists of the following menus:

Move

Used to move items to different locations in the drawing. See 8.7.2: Moving Drawing Objects.

Copy

Used to copy items to different locations in the drawing. See 8.7.1: Copying Drawing Objects and Labels.

Rotate

Used to rotate items through 90o. See 8.7.5: Rotating Drawing Objects.

Mirror

Used to mirror AVEVA P&ID entities or groups. Operates almost identically to the AutoCAD command except the mirrored object(s) are always retained. See 8.7.3: Mirroring Drawing Objects.

Stretch

Operates as for the moving command (see above) but retains connections enabling stretching to take place. See 8.7.4: Stretching Drawing Objects.

Delete

Used to delete both AVEVA P&ID and non-AVEVA P&ID entities. See 8.7.6: Deleting Drawing Objects.

12.14:49© 2011 AVEVA Solutions Ltd

Page 288: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Change to Non-Plot Layer

Use to move items to the non-plot layer. See 8.7.9: Moving Items to the Non-Plot Layer.

Find and Replace

Used for performing global editing on labels other than pipe labels. See 8.6.30: Globally Editing Labels.

Add Segment

Used to add a new segment to the end of a pipe or signal line. See 8.5.13: Adding Pipe and Signal Line Segments.

Delete Segment

Used to delete a pipe segment. See 8.5.15: Deleting Pipe and Signal Line Segments.

Merge Segment

Used to merge two pipe segments into one. See 8.5.14: Merging Pipe Segments.

Extend Segment

Used to change the length of a pipe. See 8.5.16: Changing the Length of Lines.

Elbow Stretch

Used to add an elbow to a line. See 8.5.17: Adding Elbows to a Line.

12.14:50© 2011 AVEVA Solutions Ltd

Page 289: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Split To Main Pipe

Used to split a single main pipe or signal line into two separate pipes or signal lines. See 8.5.10: Splitting Pipes and Signal Lines.

Split Branch Pipe

Used to split a section of a pipe off as a branch. See 8.5.11: Splitting off Branches.

Main to Branch Pipe

Used to change pipes into branches. See 8.5.18: Changing Pipes to Branches and Branches to Pipes.

Branch to Main Pipe

Used to change branches into pipes. See 8.5.18: Changing Pipes to Branches and Branches to Pipes.

AVEVA Connect

Used to connect nozzles to pipes. See 8.5.20: Connecting Pipes to Nozzles and Equipment.

AVEVA Disconnect

Used to disconnect nozzles from pipes. See 8.5.21: Disconnecting Pipes from Nozzles and Equipment.

12.14:51© 2011 AVEVA Solutions Ltd

Page 290: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Break

Used for manually breaking pipes, process links and signal lines where they cross other lines. See 8.5.8: Breaking Lines.

Merge Branch/Pipe

Used for merging two separate pipes, branches or signal lines into a single pipe, branch or signal line. See 8.5.9: Merging Pipes, Branches and Signal Lines.

Reverse Flow

Used to reverse the flow of a pipe. See 8.5.12: Reversing Pipe and Signal Line Flows.

• Pipeline GroupThe Pipeline Group consists of the following menus and drop-down lists:

Draw Pipeline

Used to draw pipes. The pipe will be drawn with the tracing type, pipe style and end styles selected from the above list boxes. See 8.5.1: Drawing Pipes.

Process Link

Used to draw process links between process and instrument items where the flow line has no line number. Also between two instruments where the connecting line is not a signal line. See 8.5.3: Drawing Process Links.

Instrument Link

Used to draw process links (see above) of the instrument (or "legacy") process link type. See 8.5.3: Drawing Process Links.

12.14:52© 2011 AVEVA Solutions Ltd

Page 291: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Used to select a pipe style.

Used to select pipe end styles.

Used to select a pipe tracing type.

12.14:53© 2011 AVEVA Solutions Ltd

Page 292: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Add Label

Used to add additional labels to labelled pipes. See Adding Extra Labels to a Labelled Pipe.

Change Style

Used to change the pipe style of an existing pipe. Select the new pipe style from list box described above. Then select this button followed by the pipe the style of which is to be changed. See 8.5.4: Changing Pipe Styles.

Add Trace

Used to add tracing of a project definable style to an existing pipe. Inline fittings are automatically traced around. See 8.5.5: Applying Tracing to Pipes.

BREAK

Used to switch automatic pipe breaks on or off.

ARROWS

Used to switch automatic directional flow arrows on or off.

TRACE

Used to switch automatic tracing on or off.

12.14:54© 2011 AVEVA Solutions Ltd

Page 293: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

The PIPE, EQUIP, VALVE, NOZZLE and INSTR checkboxes are used to set whether or not the Properties Dialogs of items in these categories will open automatically when an item placed on a drawing, so that the item may be labelled straight away. For example, if the Equip checkbox is checked, immediately after an equipment item is placed, the Properties dialog for the equipment opens automatically.

• Signal Line GroupDraw Signal Line

Used to draw signal lines. The style, thickness and colour are all project definable. See 8.5.6: Drawing Signal Lines.

Used to select a signal line style.

Change Style

Used to change the signal line style of existing signal lines. See 8.5.7: Changing Signal Line Styles.

• Symbol GroupThe Symbol group consists of the following menus:

Note

Notes may be added to any item except clouds. They may be up to 132 characters long and appear in the output files when an export is carried out. See 8.6.29: Adding Notes to Items.

Revision Cloud

Clouds are normally used to highlight changes from the previous revision of a drawing. This command draws revision clouds to any size. See 8.7.10: Drawing Revision Clouds.

12.14:55© 2011 AVEVA Solutions Ltd

Page 294: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Insert UDAs

Used to label items on a drawing with their User-Defined Attribute (UDA) values, including DataSet UDAs. See 8.6.33: Labelling Items with UDAs.

Assembly

Groups a collection of VPE Workbench designators and values into assemblies, also called Design Data Templates. An assembly may be repeatedly used on the same flow diagram or on other flow diagrams. See 8.9.1: Creating Assemblies.

Exchange Symbol

Used to exchange one type of symbol for another. See 8.7.7: Exchanging Individual Symbols.

Global Symbol Exhange

Used for performing all symbol exchanges other than exchanges of individual symbols. Used in conjunction with the entries in the Symbol Exchange List in the List of Values Configuration Category of the AVEVA P&ID Project Administration program. Client symbols may be converted using this procedure. See 8.7.8: Exchanging Symbols Globally.

Inherit Owner Pipe Data

Used to set individual valves and instruments to inherit their label data from a selected pipe. See 8.6.31: Setting Symbols to Inherit Label Data from a Manually Selected Pipe.

Remove Inherit Data

Used to turn off the inheritance of pipe label data for instruments, inline equipment, valves and line fittings. See 8.6.32: Switching off Label Data Inheritance from Pipes.

12.14:56© 2011 AVEVA Solutions Ltd

Page 295: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Assign Tags Equipment

Used to replace equipment tags with tags in the automatic tag format.

Assign Tags Instruments

Used to replace Instrument tags with tags in the automatic tag format.

Assign Tags Pipes

Used to replace pipe tags with tags in the automatic tag format.

Assign Tags Valves

Used to replace valve tags with tags in the automatic valve tag format. See 8.6.26: Replacing Tags with Tags in the Automatic Tag Format.

• Properties GroupThe Properties group consists of the following commands:

Properties

Used to place labels or 'intelligence' on the flow diagram. Also used to edit non-AVEVA P&ID text. See 8.6.1: Labelling - General Information.

P&ID Properties

Used to open the Non-Modal Properties Dialog.

Show Object Associations

Used to show the associations between items vessel and its nozzles. Associated items are highlighted. See 8.9.4: Show Associations between Items.

List AVEVA P&ID attributes

Lists the item handle, registered application name, code and ASCII string (item type) of a selected item. The sequence id is also shown if you choose a label. See 8.9.5: List Item Details.

12.14:57© 2011 AVEVA Solutions Ltd

Page 296: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

4.9.2 Data Management Tab

• P&ID Reports GroupP&ID Reports Launch

Used to open an AVEVA P&ID Reports database. See 8.8.4: Opening a P&ID Reports Database.

Login

Used to login to an AVEVA P&ID Reports database. See 8.8.3: Connecting to a P&ID Reports Database.

Load P&ID Grid

Used to open the P&ID Data Grid.

Refresh Grid

Used to refresh labels added to the drawing from the P&ID Data Grid. See 8.6.23: Refreshing P&ID Data Grid Labels.

• AVEVA Integration GroupThe AVEVA Integration group consists of the following commands and menus:

Synchronise

Used to validate and export data on a drawing. See 8.8.5: Synchronising Data with a VPE Workbench Database.

Login

Used to connect to a VPE Workbench database. See 8.8.7: Connecting to a VPE Workbench Database.

Logout

Used to disconnect from a VPE Workbench database. See 8.8.8: Disconnecting from a VPE Workbench Database.

12.14:58© 2011 AVEVA Solutions Ltd

Page 297: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Properties

Used to select VPE Workbench data to associate with items on the drawing. See 8.8.9: Labelling with VPE Workbench Data.

Refresh

Used to refresh VPE Workbench data displayed on a drawing. See 8.8.15: Exporting Data to ISO 15926 Files.

Insert Tables

Used to place tables of VPE Workbench data on a drawing. See 8.8.10: Inserting Tables of VPE Workbench Data.

Make Synch Batch File

Used to transfer data to VPE Workbench from a batch of drawings. See 8.8.6: Synchronising Multiple Drawing Data with VPE Workbench.

Publish to AVEVA NET

Used to export drawing data in a format that can be imported into AVEVA NET Portal. See 8.8.14: Publishing Data to AVEVA NET.

Save Work

Used to save data to a PDMS Schematic database. See 8.8.13: Transferring Data to PDMS Schematic Databases.

Piping Sequence

Used to view and edit the sequence of entities in pipes. See 8.9.7: Viewing and Editing Pipe Entity Sequences.

Delete Error Blocks

Used to delete error blocks from the drawing, for example those issued during the Synchronising Data with a VPE Workbench Database process. Deleting Error Blocks.

ISO 15926

Used to export data from a drawing to an XML file in ISO 15926 format. See 8.8.15: Exporting Data to ISO 15926 Files.

ISO 15926 Batch

Used to export data from multiple drawings to XML files in ISO 15926 format. See 8.8.15: Exporting Data to ISO 15926 Files.

• Import/Export GroupThe Import/Export group consists of the following menus and commands:

12.14:59© 2011 AVEVA Solutions Ltd

Page 298: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Excel Open

Used to open an exported Excel spreadsheet for editing. See 8.8.17: Editing P&ID Data in an Excel Spreadsheet.

Excel Import

Used to import data from an Excel spreadsheet. See 8.8.18: Importing Data from Excel.

Make Excel Import Batch File

Used to create a batch file for importing data from multiple Excel spreadsheets into multiple drawings. See 8.8.16: Exporting Data to Excel.

Excel Export

Used to export data to an Excel spreadsheet. See 8.8.16: Exporting Data to Excel.

Make Excel Export Batch File

Used to create a batch file for exporting data from multiple drawings into multiple Excel spreadsheets. See 8.8.18: Importing Data from Excel.

12.14:60© 2011 AVEVA Solutions Ltd

Page 299: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Excel Filter

Used to specify the types of data to be exported to Excel spreadsheets, e.g. drawing attributes, equipment, pipes etc. See 8.8.16: Exporting Data to Excel.

4.9.3 Utilities Tab

• Project Configuration GroupThe Project Configuration group consists of the following menus and commands:

Update Equipment Tag

Used to implement changes to equipment tags on a drawing resulting from changes to project configuration settings. See 8.2.2: Updating Equipment Tags.

Update Pipe Tag

Used to implement changes to pipe tags on a drawing resulting from changes to project configuration settings. See 8.2.3: Updating PipeTags.

Update Spec Driven Data

Used to implement changes to drawings resulting from changes to Spec Driven project configuration settings. See 8.2.4: Updating Spec Driven Data.

12.14:61© 2011 AVEVA Solutions Ltd

Page 300: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Recover Project Configuration Data

Used to resolve configuration conflicts in a drawing caused by changes to the project configuration, and to reload a fresh set of project configuration data so that the drawing may load correctly. See 8.9.9: Recovering Project Configuration Settings.

Audit

Checks the drawing for corrupted items and places an error balloon at each corrupted item insertion point. See 8.8.1: Checking for Corrupted Items.

The options on this menu are not used.

Set Aspect Ratio

Used to set the thumbnail images of symbols that may be displayed in the Symbol Explorer. Opens a dialog into which the X and Y values can be entered.

Convert Units

Used to implement changes to drawings resulting from changes to the project label units. 8.2.5: Convert Project Label Units.

Find Start Node using Branch Id

Used when the Synchronising Data with a VPE Workbench Database procedure reports that pipes have duplicated Branch Id's, this option assigns new, unique, Id's to selected pipes. See 8.9.6: Assigning a New Branch Id to a Pipe.

• Non-Intelligent Entities Upgrade GroupThe Non-Intelligent Entities Upgrade group consists of the following menus and commands:

Create Pipe

Used when upgrading AutoCAD lines to AVEVA P&ID pipes to create a pipe from selected line segments and symbols. See Creating a Pipe from Line Segments and Symbols.

12.14:62© 2011 AVEVA Solutions Ltd

Page 301: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Create Tee

Used when upgrading AutoCAD lines to AVEVA P&ID pipes to add tees to upgraded lines. See Adding Tees to Upgraded Pipe Junctions.

Reverse Pipe Segment

Used to reverse the flow direction of pipe segments. See Reversing Pipe Segments.

Add Flow Arrows to Pipe/Pipes

Used to add flow arrows to upgraded pipes. See Adding Flow Arrows to Upgraded Lines.

Remove Pipe

Used to reverse the upgrade of a pipe. See Undoing the Upgrade of a Line.

Remove Entity From Pipe

Used to remove a symbol or segment from a pipe. See Removing Entities from a Pipe.

Map Block Attributes to Pipe Field

Used to map the AutoCAD attributes of a block to AVEVA P&ID pipe fields, so that the attribute values will populate those pipe fields. See Mapping AutoCAD Attributes to AVEVA P&ID Pipe Fields.

View Upgraded Entities

Used to identify which drawing entities have been upgraded and which have not. See 5.4.4: Viewing Upgraded Entities.

Create Symbol

Used to access the Symbol Editor.

12.14:63© 2011 AVEVA Solutions Ltd

Page 302: aveva p&id

AVEVA P&ID 12.1 User GuideThe Graphical User Interface

Upgrade Entities

Used to upgrade lines and blocks to the pipe types, signal line types and symbols mapped to them using the AVEVA P&ID Drawing Upgrade Utility. See Assigning Mapped Pipe Types and Signal Types to Lines.

Export Symbols

Used to export the symbols on a drawing. It copies all the symbols on a drawing to the ExportSymbols folder of the project. From there they may be edited, or manually copied elsewhere, e.g. to another project. See 8.8.19: Exporting Symbols.

• P&ID Help GroupThe P&ID Help group consists of the following menus and commands:

AVEVA P&ID Help

Opens the AVEVA P&ID Online Guide.

AutoCAD Help

Opens the AutoCAD help system.

AVEVA P&ID Support

Opens the AVEVA Helpdesk website, which provides online support.

What's New

Opens the “What’s New” screen, which lists and briefly describes the main changes to functionality in the current version AVEVA P&ID. Selecting a link on this screen will open the help topic relevant to the improvement, where more details can be found.

About AVEVA P&ID

Opens the AVEVA P&ID "About" screen, on which general product information is displayed.

12.14:64© 2011 AVEVA Solutions Ltd

Page 303: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5 Upgrading AutoCAD Drawings

5.1 IntroductionExisting "dumb" AutoCAD drawings can be upgraded to "intelligent" AVEVA P&ID drawings by using a combination of the AVEVA P&ID Drawing Upgrade Utility and commands within AVEVA P&ID.

5.1.1 AutoCAD Drafting GuidelinesIn order for the upgrade procedure to run as smoothly as possible, it is recommenced that a number of guidelines be followed when drafting the AutoCAD drawings to be upgraded. See 5.2: AutoCAD Drafting Guidelines for details.

5.1.2 Upgrading AutoCAD Lines to AVEVA P&ID Pipes, Process Links and Signal LinesAutoCAD lines may optionally be mapped to AVEVA P&ID Pipe Types and Signal Line Types using the AVEVA P&ID Drawing Upgrade Utility. See 5.3.4: Assigning P&ID Pipe Types to AutoCAD Line Types and 5.3.5: Assigning P&ID Signal Line Types to AutoCAD Line Types.

If inline items are to be upgraded as part of the line upgrade procedure, they must be mapped to an AVEVA P&ID Symbol in the project using the AVEVA P&ID Drawing Upgrade Utility. See 5.3.3: Assigning P&ID Symbol Names to AutoCAD Blocks.

A procedure may then be carried out in AVEVA P&ID to convert AutoCAD lines to the Pipe and Signal Line Types they have been mapped to. See Assigning Mapped Pipe Types and Signal Types to Lines.

No further procedures are required to upgrade AutoCAD lines to Signal Lines and Process Links. To complete the conversion of lines to Pipes:

1. The start and end points of the line, and the entities of the line that are to be upgraded must be specified. An AVEVA P&ID pipe is then created from the selected segments and symbols. See Creating a Pipe from Line Segments and Symbols.Note that lines will be upgraded to an AVEVA P&ID Pipe of the current default Pipe Type unless a Pipe Type has already been assigned to it as described above.

2. Any entities accidentally selected for inclusion in the upgraded line can be removed from it. See Removing Entities from a Pipe.

3. Tees must then be added to the junctions of upgraded line segments. See Adding Tees to Upgraded Pipe Junctions.

4. Flow arrows can then be added to the upgraded line. See Adding Flow Arrows to Upgraded Lines.

12.15:1© 2011 AVEVA Solutions Ltd

Page 304: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5. When flow arrows are added they automatically point in the direction that the pipe was drawn in. As this may not be the flow direction, pipe segments may be reversed so that flow arrows point in the correct direction. See Reversing Pipe Segments.

6. The label balloons and connecting leader lines of inline instruments must then be associated with the instruments. See Associating Instrument Label Balloons with Inline Instruments.

5.1.3 Upgrading AutoCAD Blocks to AVEVA P&ID SymbolsThere are four ways of converting AutoCAD blocks to AVEVA P&ID symbols:

• In the AVEVA P&ID Drawing Upgrade Utility assign AVEVA P&ID Item Types and symbol property data to an AutoCAD blocks and then add those blocks as a new AVEVA P&ID Symbols to the project (see 5.3.2: Assigning P&ID Item Types and Symbol Data to AutoCAD Blocks). Like any other project symbols, they can then be added to a drawing, or selected to convert AutoCAD blocks to as described below.

• Map blocks to AVEVA P&ID Symbols using the AVEVA P&ID Drawing Upgrade Utility (see 5.3.3: Assigning P&ID Symbol Names to AutoCAD Blocks), and then upgrading them as part of the procedure for converting AutoCAD lines into AVEVA P&ID pipes (see Creating a Pipe from Line Segments and Symbols).

• Map blocks to AVEVA P&ID Symbols using the AVEVA P&ID Drawing Upgrade Utility and then upgrading all mapped blocks on a drawing using a procedure in AVEVA P&ID (see Upgrading Multiple Blocks to Symbols).

• Individually upgrading blocks in a drawing by specifying a project Symbol for them to be converted to (see Upgrading Individual Blocks to Symbols).

5.1.4 Upgrading AutoCAD Text to AVEVA P&ID LabelsNo mapping procedures in the AVEVA P&ID Drawing Upgrade Utility. A number of commands are provided in AVEVA P&ID to convert AutoCAD text to labels for different types of AVEVA P&ID items.

See 5.4.3: Upgrading Text to Labels.

5.1.5 Viewing Upgraded and Un-upgraded EntitiesA utility is provided which can be used to easily visually identify those items on drawing which have and have not been upgraded.

See 5.4.4: Viewing Upgraded Entities.

12.15:2© 2011 AVEVA Solutions Ltd

Page 305: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5.2 AutoCAD Drafting GuidelinesIn order for the upgrade procedure to run as smoothly as possible, it is recommenced that the following guidelines be followed when drafting the AutoCAD drawings to be upgraded:

• Use different layers for primary pipeline and secondary pipelines, e.g. draft all primary pipelines on the “MAJOR” layer and all secondary pipelines on the "MINOR” layer.

• All blocks should be placed with their respective names, not only on the drawing but also in the project. Avoid different names for a single block, as will commonly happen if CTRL+C and CTRL+V are used for copying block information. A block should be unique for a project: avoid duplicate block definitions.

• Use a block scale of “1”. Symmetrical blocks with their widths in whole numbers are ideal as this makes the automatic port upgrade procedure (the adding ports to symbol) more efficient, and thus less effort is required subsequently, adding ports to symbols manually.

• Information for components such as Pipes, Instruments, and Valves etc can either come from attributed text or from plain text in the right format. For example, dumb text such as "10-A-250" can be used to create a pipe tag in P&ID using the associate text facility. This information can also come from attribute definitions in AutoCAD attached to the block. In this case, the Attribute Mapping facility can be used to create tags.

• Equipment should be placed on the “EQUIP” layer.• Equipment components should be placed on the “EQPT” layer.• Piping components and inline instruments should be placed on the “PID” layer.• Offline instruments should be placed on the “INST” layer.• Connections to process lines should be placed on the “LINK” layer.• Electrical and pneumatic lines should be placed on the “ELEC” layer.• Capillary lines should be placed on the “CAPILLARY” layer.• Software lines should be placed on the “SOFT” layer.• Attributed text information shall be placed on the “ATT-TEXT” layer.• Use a different layer for each type of component.• Snap should be set to “On”.• The lines or polylines that represent a single pipe should be drawn in the same

direction (e.g. left to right).• The drawing of leader lines for instrument label balloons is recommended.

12.15:3© 2011 AVEVA Solutions Ltd

Page 306: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5.3 AVEVA P&ID Drawing Upgrade Utility

5.3.1 Starting the AVEVA P&ID Drawing Upgrade UtilityTo open the AVEVA P&ID Drawing Upgrade Utility, select AVEVA > P&ID > P&ID Drawing Upgrade from the Programs menu.

The utility is then displayed.

To select the drawings which are to be updated, select the Project Settings option from the menu on the File tab:

12.15:4© 2011 AVEVA Solutions Ltd

Page 307: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

In the Select Project Folder field, enter the location of the configuration file (.PRJ) of the P&ID project, or press the Browse button and browse for the file.

In the Select Drawing Folder field, enter the folder in which the drawings are located, or press the Browse button and browse for it.

The Drawing List pane then lists all the .DWG files in the selected folder. To select a drawings to for upgrade, check its checkbox. To check all the checkboxes, check the Select all Files checkbox.

When the required drawings have been selected, select the OK button.

The utility grids are then populated with lists of the block, line, symbol etc data from the selected drawings ready for mapping to AVEVA P&ID item types, pipe types etc.

Continue at:• 5.3.2: Assigning P&ID Item Types and Symbol Data to AutoCAD Blocks• 5.3.3: Assigning P&ID Symbol Names to AutoCAD Blocks• 5.3.4: Assigning P&ID Pipe Types to AutoCAD Line Types• 5.3.5: Assigning P&ID Signal Line Types to AutoCAD Line Types

Data in the grids can be grouped and filtered, and grid rows can be pinned. These facilities work in the same way as those in the P&ID Data Grid. Refer to P&ID Data Grid - Configuring the Grid Layout for more information.

12.15:5© 2011 AVEVA Solutions Ltd

Page 308: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5.3.2 Assigning P&ID Item Types and Symbol Data to AutoCAD BlocksAutoCAD blocks can be converted to AVEVA P&ID symbols in two ways:

• Using the Blocks setup grid, they can be mapped to an AVEVA P&ID Item Type, and have AVEVA P&ID symbol data such as Size Type, Insertion, PDMS Type etc assigned to them. When the Process button above the grid is pressed, they are converted into intelligent AVEVA P&ID symbols as new types of Symbols. This process is described below.

• Alternatively, in the Symbol Mapping grid (see 5.3.3: Assigning P&ID Symbol Names to AutoCAD Blocks), they can be mapped to an existing AVEVA P&ID Symbol in the project. Such blocks can then be converted to the selected AVEVA P&ID Symbols using procedures within the main AVEVA P&ID application (see Upgrade Procedures in AVEVA P&ID - 5.4.1: Upgrading Lines to Pipes and Signal Lines and 5.4.2: Upgrading Blocks to Symbols).

Open the Blocks setup grid by clicking this button:

The grid is then displayed.

The Symbol Name column lists the blocks from the selected drawings.

12.15:6© 2011 AVEVA Solutions Ltd

Page 309: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

To view a symbol, click on its entry. It is then displayed in a separate window.

In the P&ID Type column, select the P&ID Item Types to be mapped to the blocks.

If a block is to be defined as a new symbol in the P&ID project., edit the Size Type, Insertion etc columns to define the symbol data for that block. See AVEVA P&ID Project Administration Program - Symbols Configuration Category - Entering Symbol Data for guidance.

The next step is to process the blocks to add intelligence to them. If a block is to be included from this process, check its Include checkbox.

Press the UnSelect All button to uncheck all Include checkboxes. The name of the button then changes to Select All. Press it to check all Include checkboxes.

Whether or not the symbol definitions are to be added to the catalogue of project symbols (as displayed in the Symbols Configuration Category of the AVEVA P&ID Project Administration Program) is controlled by the Add symbol to catalogue / Do not add Symbol to catalogue toggle button. If the button is set to Do not add Symbol to catalogue, blocks are not added to the symbol catalogue. If the button is set to Add Symbol to catalogue, they are.

Whether or not symbols with the same file names are to be overwritten in the project symbol folder is controlled by the Export all symbols / Do not export existing Symbols toggle button. If the button is set to Do not export existing Symbols, existing symbols are not overwritten. If the button is set to Export all symbols, they are.

Press the Process button. The blocks are then opened in AVEVA P&ID and intelligence is added to them to convert them into AVEVA P&ID symbols. They are processed one at a time.

12.15:7© 2011 AVEVA Solutions Ltd

Page 310: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

A dialog is opened which displays each block as it is processed:

Once the process is converted, a message displays the number of symbols successfully export.

The selected symbols are copied to ExportSymbols folder of the project, as displayed in the message. They can be viewed by clicking on this folder in the Symbol Explorer.

Note: Ports must now be added to the new symbols. Refer 4.4: Symbol Editor for details.

To view the log file of messages generated during the process press the View Log button. The file then opens in Notepad.

5.3.3 Assigning P&ID Symbol Names to AutoCAD BlocksAutoCAD blocks may be added to the project as new Symbols (see 5.3.2: Assigning P&ID Item Types and Symbol Data to AutoCAD Blocks for details).

Alternatively they may be mapped to existing project Symbols and converted to symbols of these types using a procedure in the main AVEVA P&ID application (see 5.4.2: Upgrading Blocks to Symbols).

12.15:8© 2011 AVEVA Solutions Ltd

Page 311: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

The mapping procedure is carried out using the Symbol mapping grid. Open the Symbol mapping grid by clicking this button:

The grid is then displayed.

The Symbol Name column lists the names of the AutoCAD blocks.

From the Mapped Symbol column, select the AVEVA P&ID project Symbol to map to each AutoCAD block. By default, if there is project Symbol with the same name as a block, this will be automatically selected. However a different Symbol can be selected if required.

To delete a mapping row, select it and press the Delete button.

AutoCAD block attributes can be mapped to AVEVA P&ID properties.

Click on a symbol name. The Properties dialog is then displayed, listing all the AutoCAD attribute names of the selected block.

12.15:9© 2011 AVEVA Solutions Ltd

Page 312: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

In the MappedName fields, select AVEVA P&ID properties to map the attributes to.

The following P&ID Item Types support attribute mapping:

Instruments (INS)

All Valves types (V*)

Nozzles (NOZ)

Reducers (RDC)

Spec Breaks (LSP)

Pipe Connector Flags (PFL)

When the block is upgraded to an AVEVA P&ID symbol, the mapped AVEVA P&ID properties will automatically be populated with the values of the AutoCAD attributes they are mapped to.

Once all Symbol names and attributes have been mapped, press the Save button.

12.15:10© 2011 AVEVA Solutions Ltd

Page 313: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5.3.4 Assigning P&ID Pipe Types to AutoCAD Line TypesThe Pipe Line mapping grid is used to map AutoCAD lines to AVEVA P&ID Pipes Types, including process links.

AutoCAD lines are mapped to AVEVA P&ID signal lines using the Signal Line mapping grid (see 5.3.5: Assigning P&ID Signal Line Types to AutoCAD Line Types).

To open the Pipe Line mapping grid, press this button:

The grid is then displayed.

1. Select the Add button to add a row to the grid.2. In the Pipe Type field, select the AVEVA P&ID Pipe Type that each line is to be mapped

to. 3. In the Line, Layer, Line Type and Colour columns enter the properties of the AutoCAD

line in the selected drawings that is to be mapped to the selected AVEVA P&ID Pipe Type.

4. If a line type represents a process link, check its IsProcessLink checkbox.5. Repeat the above procedure for each type of AutoCAD line to be mapped.6. To delete a mapping row, select it and press the Delete button.7. Once the pipe types have been mapped, press the Save button to save the mappings.

A procedure can then be carried out in AVEVA P&ID to apply the mapped types to AutoCAD lines. Further procedures can then be carried out to convert these lines into AVEVA P&ID pipes. For details, see 5.4.1: Upgrading Lines to Pipes and Signal Lines.

5.3.5 Assigning P&ID Signal Line Types to AutoCAD Line TypesThe Line-Signal Mapping grid is used to map AutoCAD lines to AVEVA P&ID Signal Line Types.

AutoCAD lines are linked to pipe types and process links using the Pipe Line mapping grid (see 5.3.4: Assigning P&ID Pipe Types to AutoCAD Line Types).

12.15:11© 2011 AVEVA Solutions Ltd

Page 314: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

To open the Signal Line mapping grid, press this button:

The grid is then displayed.

1. Select the Add button to add a row to the grid.2. In the Signal Type field, select the AVEVA P&ID Signal Type that each line is to be

mapped to. 3. In the Line, Layer, Line Type and Colour columns enter the properties of the AutoCAD

line in the selected drawings that is to be mapped to the selected AVEVA P&ID Signal Type.

4. Repeat the above procedure for each type of AutoCAD line to be mapped.5. To delete a mapping row, select it and press the Delete button.6. Once the Signal Types have been mapped, press the Save button to save the

mappings.

A procedure can then be carried out in AVEVA P&ID to apply the mapped types to AutoCAD lines, converting them to AVEVA P&ID Signal Lines. For details, see 5.4.1: Upgrading Lines to Pipes and Signal Lines.

12.15:12© 2011 AVEVA Solutions Ltd

Page 315: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5.4 Upgrade Procedures in AVEVA P&ID

5.4.1 Upgrading Lines to Pipes and Signal LinesThis procedure is used to upgrade AutoCAD lines into AVEVA P&ID pipes, process links and signal lines, including, if required, all the inline fittings, valves etc.

Note: If it is required to generate a simple line list from AVEVA P&ID using the Synchronize facility (see 8.8.5: Synchronising Data with a VPE Workbench Database), it is not necessary to upgrade inline symbols. Line lists can be generated from "semi-intelligent" drawings in which only the lines themselves have been upgraded to pipes.

The procedure is as follows:

1. Assign AVEVA P&ID Pipe Types and Signal Types to AutoCAD lines, as specified by mappings setup in the AVEVA P&ID Drawing Upgrade Utility. The upgraded lines will adopt the appearance of the specified pipe types and signal types. See Assigning Mapped Pipe Types and Signal Types to Lines.

2. The start and end points of the line, and the entities of the line to be upgraded must be specified. An AVEVA P&ID pipe is then created from the selected segments and symbols. See Creating a Pipe from Line Segments and Symbols.

3. Any entities accidentally selected for inclusion in the upgraded line can be removed from it. See Removing Entities from a Pipe.

4. Tees must then be added to the junctions of upgraded line segments. See Adding Tees to Upgraded Pipe Junctions.

5. Flow arrows can then be added to the upgraded line. See Adding Flow Arrows to Upgraded Lines.

6. When flow arrows are added they automatically point in the direction that the pipe was drawn in. As this may not be the flow direction, pipe segments may be reversed so that flow arrows point in the correct direction. See Reversing Pipe Segments.

7. The label balloons and connecting leader lines of inline instruments must then be associated with the instruments. See Associating Instrument Label Balloons with Inline Instruments.

8. The upgraded line should now be labelled, either by using standard labelling facilities (see 8.6.1: Labelling - General Information), or by upgrading AutoCAD text and associating it with the line (see Upgrading Pipe Text). Optionally, the AutoCAD attributes of a block can be mapped to AVEVA P&ID pipe fields. The upgraded line can then be selected, and the values of the attributes will then automatically populate the pipe property fields they were mapped to. See Mapping AutoCAD Attributes to AVEVA P&ID Pipe Fields.

If required, an upgraded line may be changed back into a dumb AutoCAD line. See Undoing the Upgrade of a Line.

• Assigning Mapped Pipe Types and Signal Types to LinesThe Pipe Types and Signal Types mapped to AutoCAD lines in the AVEVA P&ID Drawing Upgrade Utility (see 5.3.4: Assigning P&ID Pipe Types to AutoCAD Line Types and 5.3.5: Assigning P&ID Signal Line Types to AutoCAD Line Types) are applied to all the AutoCAD lines in a drawing by:

1. Selecting the Upgrade Utility Commands > Upgrade Entities option from the shortcut menu of The Drawing Page or the Upgrade Entities option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab..

12.15:13© 2011 AVEVA Solutions Ltd

Page 316: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

2. All AutoCAD lines in the drawing with sets of properties mapped to AVEVA P&ID Pipe or Signal Types are then converted to lines in the mapped types and will adopt the appearance of these types.

Note: When lines that have not had AVEVA P&ID Pipe or Signal Types assigned to them using this procedure are upgraded to pipes using the procedure below, they will automatically adopt the current default Pipe Type.

Note: This procedure will also convert all AutoCAD blocks that have had AVEVA P&ID Symbol Types mapped to them in the in the AVEVA P&ID Drawing Upgrade Utility (see 5.3.3: Assigning P&ID Symbol Names to AutoCAD Blocks) to AVEVA P&ID symbols of the mapped types.

No further upgrade procedures are required to convert AutoCAD lines to AVEVA P&ID Signal Lines and Process Links. To complete the conversion of AutoCAD lines to AVEVA P&ID Pipes (and Process Links), proceed as described below.

• Creating a Pipe from Line Segments and Symbols1. Select the Upgrade Utility Commands > Pipe Upgrade > Create Pipe option from

the shortcut menu of The Drawing Page or the Create Pipe option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Command prompt will display:

Pick start point of the line:

Pick the start of point of the line to be upgraded.2. The Command prompt will display:

Pick second point to determine angle:

Pick a point a little further along the line from the start point.3. The Command prompt will display:

Pick start point of the line:

Pick the end point of the line.4. The Command prompt will display:

Pick second point to determine angle:

Pick a point a little way back along the line from the end point.

12.15:14© 2011 AVEVA Solutions Ltd

Page 317: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5. The Command prompt will display:

Please select entities in the correct sequence, upstream to downstream:

Select all the segments, and if they are to upgraded, the symbols that the pipe is to consist of from upstream to downstream. The command prompt will display a count of the number of entities selected.

6. Press Enter. The line and all selected entities will then be upgraded.

The line will then be upgraded to an AVEVA P&ID pipe of the default Pipe Type (unless a Pipe or Signal Type has already been assigned to it as described above).

The line will be upgraded to the type of pipe, process link or signal line specified for the AutoCAD line type in the AVEVA P&ID Drawing Upgrade Utility (see 5.3.4: Assigning P&ID Pipe Types to AutoCAD Line Types and 5.3.5: Assigning P&ID Signal Line Types to AutoCAD Line Types).

Select symbols will be upgraded to the types of items and symbols specified for the AutoCAD block in the AVEVA P&ID Drawing Upgrade Utility (see 5.3.2: Assigning P&ID Item Types and Symbol Data to AutoCAD Blocks and 5.3.3: Assigning P&ID Symbol Names to AutoCAD Blocks).

If no mapping has been set up for a line type or block in the AVEVA P&ID Drawing Upgrade Utility, it will not be upgraded.

Note: The sequence of entities in a pipe can be checked and if necessary edited using the Viewing and Editing Pipe Entity Sequences procedure. This procedure can also be used to add and remove entities to and from a pipe.

• Removing Entities from a Pipe1. To remove entities from an upgraded pipe, that for example may have been selected

for inclusion in a pipe by mistake in the above upgrade procedure, select the Upgrade Utility Commands > Pipe Upgrade > Remove Entity option from the shortcut menu of The Drawing Page or the Remove Entity From Pipe option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Command prompt will display:

Select entity:

2. Select the entity to be removed from the pipe.

Press Enter. The selected entity is then removed from the pipe.

12.15:15© 2011 AVEVA Solutions Ltd

Page 318: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

• Adding Tees to Upgraded Pipe Junctions1. Select the Upgrade Utility Commands > Pipe Upgrade > Create Tee option from the

shortcut menu of The Drawing Page or the Create Tee option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Command prompt will display:

Select objects:

2. Select all the objects of the pipe that is to have a tee added to end of it, and all the objects of the pipe that it forms a junction with.

Press Enter. The tee will then be added.

• Adding Flow Arrows to Upgraded Lines1. Select the Upgrade Utility Commands > Pipe Upgrade > Add Flow Arrows to Pipe/

Pipes option from the shortcut menu of The Drawing Page or the Add Flow Arrows To Pipe option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Command prompt will display:

Select Pipe/Pipes to add flow arrows:

2. Select the pipes to which flow arrows are to be added.

Press Enter. The flow arrows will then be added to selected pipes.

• Reversing Pipe Segments1. Select the Upgrade Utility Commands > Pipe Upgrade > Reverse Pipe Segment

option from the shortcut menu of The Drawing Page or the Reverse Pipe Segment option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Command prompt will display:

Select Segments to reverse flow:

Select the segments the flow of which is to be reversed.2. Press Enter. The flow direction of the selected segments is then reverse, as indicated

by the flow arrows.

• Associating Instrument Label Balloons with Inline Instruments1. Select the Associate as Label Balloon option fromThe Drawing Page shortcut menu

of the label balloon. Note that the balloon symbol must have been upgraded. The Command prompt will display:

Select Symbol to Associate Balloon:

Select the appropriate instrument symbol.

12.15:16© 2011 AVEVA Solutions Ltd

Page 319: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

2. The Command prompt will display:

Select Leader Line for the Balloon:

Select the leader line connecting the balloon symbol to the instrument symbol.

The selected balloon and leader line are then associated with the instrument.

• Mapping AutoCAD Attributes to AVEVA P&ID Pipe Fields1. Select the Upgrade Utility Commands > Pipe Upgrade > Map Block Attributes to

Pipe Fields option from the shortcut menu of The Drawing Page or the Map UDAs To Pipe Field option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Command prompt will display:

Select Block for Pipe Attributes:

Pick the block that attributes will be mapped from.2. The Properties dialog will then be displayed:

The dialog displays the names and values of the block's attributes. Select the pipe fields to map the attributes to in the Pipe Field fields. Click OK.

12.15:17© 2011 AVEVA Solutions Ltd

Page 320: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

The following P&ID Item Types support attribute mapping:

Instruments (INS)

All Valves types (V*)

Nozzles (NOZ)

Reducers (RDC)

Spec Breaks (LSP)

Pipe Connector Flags (PFL)3. The Command prompt will display:

Select Pipe/Pipes for Attribute Mapping:

Select the pipe or pipes to which the block attributes will be mapped.4. Press Enter. The property fields of the selected pipes will then be populated with the

values of the attributes mapped to them.

• Undoing the Upgrade of a Line1. To reverse the upgrade of a pipe, reverting the pipe and it's entities to dumb AutoCAD

lines and blocks, elect the Upgrade Utility Commands > Pipe Upgrade > Remove Pipe option from the shortcut menu of The Drawing Page or the Remove Pipe option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab. The Command prompt will display:

Select Pipe:

Select the pipe.2. Press Enter. The pipe will then be converted back into an AutoCAD line and its symbols

into AutoCAD blocks.

Note that the formatting of the pipe, for example its colour and line style does not revert. It maintains its upgraded appearance but is not longer and "intelligent" AVEVA P&ID pipe.

5.4.2 Upgrading Blocks to Symbols"Dumb" AutoCAD blocks may be upgraded to "intelligent" AVEVA P&ID symbols as part of the procedure for upgrading lines to pipes. See 5.4.1: Upgrading Lines to Pipes and Signal Lines.

Other symbols, such as offline instruments and equipment should be upgraded using the following procedures.

All AutoCAD blocks on that drawing have been mapped to AVEVA P&ID project Symbols using the AVEVA P&ID Drawing Upgrade Utility (see 5.3.3: Assigning P&ID Symbol Names to AutoCAD Blocks) can be upgraded to the mapped Symbols in one go. AutoCAD blocks that have not been mapped must be upgraded individually.

12.15:18© 2011 AVEVA Solutions Ltd

Page 321: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

• Upgrading Multiple Blocks to SymbolsTo upgrade all the blocks on a drawing to the project Symbols they have been mapped to in the AVEVA P&ID Drawing Upgrade Utility:

1. Select the Upgrade Utility Commands > Upgrade Entities option from the shortcut menu of The Drawing Page or the Upgrade Entities option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab.

2. All AutoCAD blocks in the drawing with Symbol mapping set up for them in the AVEVA P&ID Drawing Upgrade Utility are then converted to the mapped AVEVA P&ID Symbols.

Note: This procedure will also upgrade all AutoCAD lines with properties that have been mapped to an AVEVA P&ID Pipe Type or Signal Type to Pipes/Signal Lines of those types (see 5.3.4: Assigning P&ID Pipe Types to AutoCAD Line Types and A5.3.5: Assigning P&ID Signal Line Types to AutoCAD Line Types).

• Upgrading Individual Blocks to SymbolsIf a block has not been mapped to an AVEVA P&ID Symbol, or it is not required to be converted to the Symbol it is mapped to, upgrade it as follows:

1. Right-click on the block to be upgraded and select the Upgrade Symbol option from the drawing page shortcut menu. The Command prompt will display:

12.15:19© 2011 AVEVA Solutions Ltd

Page 322: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

2. The Symbol List dialog is then displayed, from which the type of symbol that the block is to be upgraded to is selected:

3. Select the category of symbol from the left-hand window, and then the name of the symbol from the left-hand window. If the name of the symbol is known, but not its category, enter the name of the symbol in the Find field, and click on the Find button. To select a symbol, click on it in the right-hand window. An image of it is displayed in the lower half of the dialog box, along with the symbol name and description. Press the OK button.

4. The block is then converted to an AVEVA P&ID symbol of the selected type.

12.15:20© 2011 AVEVA Solutions Ltd

Page 323: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

5.4.3 Upgrading Text to LabelsAutoCAD text can be upgraded to an AVEVA P&ID label by associating it with the pipe or item that it is to label. The text then changes, if required, to reflect the properties of the selected pipe or item, and becomes a P&ID label.

This facility is available for pipes, nozzles, valves and instruments. Continue at:• Upgrading Pipe Text• Upgrading Nozzle and Valve Text• Upgrading Instrument Text

• Upgrading Pipe TextAutoCAD text can be upgraded either to a full pipe label, which will consist of all the properties included in the project pipe label format, or a partial pipe label which will consist of a single pipe property.

Multiple label formats can be configured using the Select a Tag Format For Pipe dialog (see below). The user can then select from these when upgrading text to pipe labels, or set up a different format.

To upgrade AutoCAD text using the pipe label format currently selected in the Select a Tag Format For Pipe dialog, select the AutoCAD text on The Drawing Page, then select Drawing Upgrade Associate > Associate Text > To Pipe from the shortcut menu.

The Tag Attributes List dialog is then displayed:

The dialog lists the attributes and values of the selected text. As required, in the Association column, match values to either the Tag, Start Node or End Node of the pipe to be labelled with the text. The selected text will form the labels of these parts of the pipe.

Select OK.

12.15:21© 2011 AVEVA Solutions Ltd

Page 324: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

The following will then be displayed if the tag format does not match the format of the selected text:

If Yes is selected, the Select a Tag Format For Pipe dialog is then displayed. Select or create a tag format as described below. If No is selected, the commands then ends.

After a tag format has been selected, or if the tag format does match the format of the selected text, the Command prompt will then display:

Select pipe to associate label:

Select the pipe that the selected text is to become a label of.

The text will then be changed to an AVEVA P&ID label of the selected pipe, and if required will change to reflect the properties of the pipe.

Note: Alternately, existing pipe labels can be changed to a selected AutoCAD text value. In this case, the AutoCAD text will remain as it is, and the labels of the selected pipe will change to it, i.e. the pipe properties will be updated with the AutoCAD text value. Whether or not this option is applied is dependent on the setting of the Upgrade Label checkbox on the Select a Tag Format For Pipe dialog (see below).

If attribute values were mapped to the pipe start and/or end nodes in the Tag Attributes List dialog, the user will be prompted to position these values as pipe destination text. For example:

Select start node to associate label:

- Setting Up Pipe Label Format or Selecting a Different Pipe Label Format

To configure label formats for upgrading pipe text, or to select a different existing format to apply to AutoCAD text, select AutoCAD text on The Drawing Page, then select Drawing Upgrade Associate > Associate Text > Configure... from the shortcut menu.

12.15:22© 2011 AVEVA Solutions Ltd

Page 325: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

The Select a Tag Format For Pipe dialog is then displayed.

Those formats previously set up are listed in this dialog.

To configure a new format:

1. Click the New button. The Tag Format Editor dialog is then displayed.

2. Enter a description, plus any remarks if required.

12.15:23© 2011 AVEVA Solutions Ltd

Page 326: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

3. The drop-down lists in the lower part of the dialog are used to select the label format, i.e. the properties of the pipe that are to displayed, the order that they are to be displayed in, and the delimiters that are to separate them. Select the properties and delimiters from the list as required.

Note: If a format with more that one property is to be configured, i.e. a full pipe label, it must be in exactly the same format as the Display Label Format, as set up on the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program.

The selected format is displayed in the field at the top of the dialog.4. Once the required format has been set up, click Save. The dialog is then closed and

the new format added to the list in the Select a Tag Format For Pipe dialog.

To edit an existing format, select it from the list and click the Edit button. The Tag Format Editor dialog is then displayed. Edit the format as described above.

To delete a format, select it from the list and click the Delete button.

To select a format to apply to AutoCAD text, click on it in the list of formats, and click the Select button on the toolbar (top-right corner of the dialog). Until a different format is selected from this dialog, all text upgraded to a pipe label will adopt this format.

If, instead of AutoCAD text being upgraded to AVEVA P&ID labels, the existing labels of pipes are to be changed to the values of the AutoCAD text, ensure that the Upgrade Label checkbox is not checked.

• Upgrading Nozzle and Valve TextThe procedures for upgrading AutoCAD text to a nozzle label and a valve label are the same.

AutoCAD text can be upgraded to either the tag value or the size value of a nozzle or valve.

Select AutoCAD text on The Drawing Page, then select Drawing Upgrade Associate > Associate Text > To Nozzle > or To Valve >, then either Tag or Size as required from the shortcut menu.

The Command prompt will then display, for example:

Select nozzle:

Select the nozzle or valve that the selected text is to become a label of.

The text will then be changed to an AVEVA P&ID label of the selected item, and if required will change to reflect the tag or size of that item.

• Upgrading Instrument TextAutoCAD text is upgraded to instrument labels by selecting, for each piece of text, which instrument property that text is to become.

To upgrade AutoCAD text to an instrument label, select the instrument label balloon on The Drawing Page, then select Associate Text from the shortcut menu.

12.15:24© 2011 AVEVA Solutions Ltd

Page 327: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

The Associate Text to Instrument Label dialog is then displayed.

In the dialog, click the ... button for the instrument component, for example Alarm 1, that the AutoCAD text is to be upgraded to.

The dialog then closes and the Command prompt will display, for example:

Select text to associate with InstrumentAlarm1:

Select the text that is to be upgraded to the selected instrument property.

The dialog is then displayed again. Repeat the above procedure for each piece of AutoCAD text to be upgraded by association with the selected instrument.

When each piece of AutoCAD text has been associated with an instrument property, click OK.

The AutoCAD text will then be changed to AVEVA P&ID labels displaying the selected properties, and if required will change to reflect the values of those properties.

5.4.4 Viewing Upgraded EntitiesAVEVA P&ID includes a utility which can be used to quickly identify which drawing entities have been upgraded and which have not, using colour.

From The Drawing Page shortcut menu of a drawing, select View Upgraded Entities or select View Upgraded Entities option in the Non-Intelligent Entities Upgrade Group of the Utilities Tab.

12.15:25© 2011 AVEVA Solutions Ltd

Page 328: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

The AVEVA Dwg Viewer dialog is then displayed.

The dialog displays the selected drawing. Standard toolbar buttons are provided to pan, zoom in, zoom out etc.

Initially, all drawing entities are displayed in grey. To apply different colours to different types and states (upgraded or not upgraded) of entities, select the Set Colours button.

12.15:26© 2011 AVEVA Solutions Ltd

Page 329: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

The following dialog is then displayed.

To specify a colour for a type of upgraded item, for labels, errors, warning and for entities that have not been upgraded ("Undefined Entities"), click on the colour field next to the type of entity. Select the required colour from the dialog that is then displayed. When the required colours have been selected, click OK.

12.15:27© 2011 AVEVA Solutions Ltd

Page 330: aveva p&id

AVEVA P&ID 12.1 User GuideUpgrading AutoCAD Drawings

To apply the colours, select the Apply Colours Settings button. The selected colours are then applied to the drawing view.

Entities that have errors or warnings associated with them can be displayed in specific colours, as described above. To view an error or warning, hover the mouse cursor over the entity in question:

12.15:28© 2011 AVEVA Solutions Ltd

Page 331: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6 Drawing P&IDs

6.1 Quick Guide to Drawing P&IDsThe table below lists the procedures that are undertaken in order to draw a P&ID. Alongside the procedures are references to the most efficient way a user can make use of the AVEVA P&ID graphical user interface in order to carry out each procedure.

To learn more about each procedure, click on 'Details'. To learn more about a part of the graphical user interface, click on the appropriate link text. There are links from all the pictures of the toolbar buttons.

See also 8: AVEVA P&ID Procedures.

Procedure Best use of the Graphical User Interface

Create a new drawing See 6.2: Creating a New Drawing.

Create a new AVEVA P&ID drawing, plus any required templates.

Start to draw the P&ID in AVEVA P&ID.

Add a title and other general data to the drawing See 6.4: Titling a Drawing.

Complete the Properties Dialogs for the drawing.

Insert equipment, valves, line fittings, instruments and so on See 6.5: Inserting Symbols.

Select and insert the symbols using the Symbol Explorer.

Insert items in project database not yet placed on a P&ID 6.7: Inserting Unassigned VPE Workbench Items.

Select and insert items from the Unassigned node of the Engineering Explorer.

Label the symbols with tag and other engineering data. See 6.10: Labelling Symbols.

Complete the Properties Dialogs of the items.

Will activate automatically after symbol is placed if “Auto-labelling” has been turned on in the Pipeline Group of the Home Tab.

12.16:1© 2011 AVEVA Solutions Ltd

Page 332: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Draw the required pipes, branches and process links See 6.8: Drawing Pipes and Connections.

Use the Pipeline Group of the Home Tab to choose the required type, style, tracing style and end styles, and whether flow arrows, breaks and tracing are placed automatically.

Select the Draw Pipeline option in the Pipeline Group of the Home Tab to start drawing pipes.

Select the Process Link option in the Pipeline Group of the Home Tab to draw process links.

To edit lines and segments use the options in the Modify Group of the Home Tab.

Select the Add Trace option in the Pipeline Group of the Home Tab to add pipe tracing manually

To add flow arrows manually insert an arrow symbol.

Label the pipes See 6.11: Labelling Pipes.

Complete the Properties Dialogs for the pipes, plus reducers and spec breaks

Will activate automatically after pipe is drawn if "Auto-labelling" has been turned on in the Pipeline Group of the Home Tab.

If required, set pipe labels as the "main" pipe labels using The Drawing Page shortcut menus.

Set valves and instruments to inherit label data from pipes See 6.10.4: Label Inheritance from Owning Pipes.

Select the Inherit Owner Pipe Data option in the Symbol Group of the Home Tab.

Draw the required signal lines See 6.8.2: Drawing Signal Lines.

Use the Signal Line Group of the Home Tab to choose the required signal line style.

Select the Draw Signal option in the Signal Line Group of the Home Tab.

Modify the style of existing pipes and signal lines

Select the Change Style option in the Pipeline Group of the Home Tab to modify pipe styles.

Select the Change Style option in the Signal Line Group of the Home Tab to modify signal line styles.

Group together items to form assemblies See 6.14: Assemblies.

Select the Assembly option in the Symbol Group of the Home Tab.

Procedure Best use of the Graphical User Interface

12.16:2© 2011 AVEVA Solutions Ltd

Page 333: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Add "Dynamic Labels" as required See 6.16: Dynamic Labelling.

Connect to VPE Workbench database by selecting the Loginoption in the AVEVA Integration Group of the Data Management Tab.

Choose VPE Workbench data to label drawing by selecting the Properties option in the AVEVA Integration Group of the Data Management Tab.

If the selected data is subsequently changed in VPE Workbench, select the Refresh option in the AVEVA Integration Group of the Data Management Tab.

Disconnect from VPE Workbench by selecting the Logoutoption in the AVEVA Integration Group of the Data Management Tab.

Add notes and revision clouds See 6.17: General Editing, Notes and Revision Clouds.

Select the Note option in the Symbol Group of the Home Tab.

Select the Revision Cloud option in the Symbol Group of the Home Tab.

Moving objects to and from the non-plot layer. See 6.17: General Editing, Notes and Revision Clouds.

Select the Change to Non-Plot Layer option in the Modify Group of the Home Tab.

Edit labels and properties or symbols and pipes

Access the relevant Properties Dialogs and change the entered data as required.

To bulk edit large numbers of labels, use the Find and Replace facility (non-pipe labels only) or the Excel Interface. See 8.6.30: Globally Editing Labels or 7.8: Transferring Data to and from Excel.

Perform any required symbol exchange, i.e. swapping one symbol for another See 6.17: General Editing, Notes and Revision Clouds.

To change symbols individually, select the Exchange Symbol option in the Symbol Group of the Home Tab.

To change multiple symbols at once, select the Global Symbol Exchange option in the Symbol Group of the Home Tab.

General Editing - Copying and Moving See 6.17: General Editing, Notes and Revision Clouds.

Copy or move items by selecting them on The Drawing Pageand selecting the Copy and Cut options from the drawing page short cut menus. Indicate the required location(s) that the items are to be moved or copied to.

The Copy and Move options on the Engineering Explorershortcut menus can also be used to copy and move items or collections of items.

Procedure Best use of the Graphical User Interface

12.16:3© 2011 AVEVA Solutions Ltd

Page 334: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.2 Creating a New Drawing AVEVA P&ID drawings can be created by using one of the following methods:

• Creating and saving a new drawing in AVEVA P&ID.• Opening an AutoCAD drawing in AVEVA P&ID, adding "intelligence", and saving.• Upgrading an existing "dumb" AutoCAD drawing to an "intelligent" AVEVA P&ID

drawing. See Upgrading AutoCAD Drawings.

When an AVEVA P&ID drawing is opened, AVEVA P&ID will start automatically.

Before actual drawings are created, it is recommended that an administrator should create a set of AutoCAD template drawings on which a user can base a new drawing (see 3.2: Templates).

If an appropriate template drawing has not been generated, create a drawing in AVEVA P&ID with the desired drawing size, and load line types and layers into it as required. Assign colours and line types to the layers. Use Ortho/Axis Lock and Snap On to prevent pipe start/end nodes being rotated. Starting and Exiting AVEVA P&ID

General Editing - Mirroring, Stretching and Rotating See 6.17: General Editing, Notes and Revision Clouds.

Mirroring: select the Mirror option in the Symbol Group of the Home Tab.

Stretching: select the Stretch option in the Symbol Group of the Home Tab.

Rotating: Select the relevant items on the drawing and select Rotate from the drawing page shortcut menu.

General Editing - Deleting See 6.18: Deleting Items.

Select the relevant items on the drawing and select Deletefrom the drawing page shortcut menu.

The Delete option on the Engineering Explorer shortcut menus can also be used to delete items or collections of items.

General Editing - Undoing changes to the drawing See 6.17: General Editing, Notes and Revision Clouds.

Select Undo from the The Drawing Page shortcut menus.

Validate and export P&ID data See 7.5: Exporting Data to a VPE Workbench Database.

If exporting direct to VPE Workbench, connect to VPE Workbench database by selecting the Login option on the Engineering Explorer shortcut menu for the drawing.

To start export, select the Synchronize with VPE Workbench option drawing shortcut menu of the Engineering Explorer.

Disconnect from VPE Workbench by selecting the Logoutoption on the Engineering Explorer shortcut menu.

Procedure Best use of the Graphical User Interface

12.16:4© 2011 AVEVA Solutions Ltd

Page 335: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.3 Starting and Exiting AVEVA P&IDWhenever a AVEVA P&ID drawing is opened in AutoCAD, AVEVA P&ID is initialised automatically.

AVEVA P&ID can also be opened from the Programs menu e.g. AVEVA Plant > Engineer > P&ID 12.1 > Projects > [Project Name] > AVEVA P&ID 12.1 [Project Name]) or a desktop shortcut:

When AVEVA P&ID is initialised, a "What's New" screen is displayed, which lists and briefly describes the main changes to functionality in the current version AVEVA P&ID. Selecting a link on this screen will open the help topic relevant to the improvement, where more details can be found. If you do not want this screen to appear every time you start AVEVA P&ID, check the Don't Show Me This Screen Again checkbox.

Note that drawings can only be opened from the folder specified in the Drawing Location field in the Project Configuration Category of the AVEVA P&ID Project Administration program, and from sub-folders in that folder.

AVEVA P&ID can be closed using the standard AutoCAD methods e.g. File > Close which leaves AutoCAD running, or File > Exit that closes both the drawing and AutoCAD, or by selecting the drawing in the explorer, clicking the right mouse button and selecting the Close menu command.

Multiple drawings can be opened in a single AutoCAD session. Each one will display in the explorer. Selecting the drawing in the explorer makes it the active drawing in AutoCAD.

6.4 Titling a Drawing Typically the first action taken when producing a drawing is to add a title and other general drawing information. This is carried out by completing the drawing Properties dialog (see 4.8: Properties Dialogs), which can be initialised by pressing the right mouse button over the drawing sheet, with no objects selected, and selecting the Properties option on the menu.

On completion of the Properties dialog, a title block is added to the drawing, which can be completed as required with the drawing number, sheet number, revision, clients drawing number and five lines of a drawing title. The drawing number is the only mandatory addition.

An advanced button exists on this Properties dialog which also adds additional sheet level data i.e.: Last line number used. Completion of this data is optional.

It is good practice to state the AVEVA P&ID release number, somewhere on the drawing in normal text (that is, in AutoCAD text).

It should be noted that the validation and transfer of the engineering data to VPE Workbench cannot proceed without a drawing number.

12.16:5© 2011 AVEVA Solutions Ltd

Page 336: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.5 Inserting SymbolsNote: For projects developed using versions of AVEVA P&ID older than AVEVA VPE P&ID

7.2 SP3, an upgrade of the symbols on the project drawings is required. See 2.1: Upgrading Pipes and Symbols from old Projects.

Symbols can be inserted using the Symbol Explorer. Alternatively, symbols can be inserted using the AVEVA P&ID Tool Palette.

Unassigned P&ID Database items can be inserted from the P&ID Data Grid. See 6.6: Inserting Unassigned P&ID Database Items for details.

Unassigned VPE Workbench items can be inserted from the Engineering Explorer. See 6.7: Inserting Unassigned VPE Workbench Items for details.

For further details, see: • 8.4.1: Inserting Symbols - General Information • 8.4.5: Inserting Valves (for example: check, process, diverter, variable inlet, manual

general, globe, 3-way) • 8.4.2: Inserting Equipment (for example: vessel, pump, heater, fan, blower,

compressor, hoist, fork lift truck) • 8.4.3: Inserting Electrical Equipment (for example: electric motor, agitator) • 8.4.7: Inserting Inline Fittings (for example; concentric reducer, blind spade, duct fitting,

flame trap, end cap, expansion bellows. Note that the category includes spec break and destination flag)

• 8.4.6: Inserting Instrument Valves (Control Valves) (for example; diaphragm-actuated, piston actuated, pressure relief, also includes vacuum/relief devices)

• 8.4.8: Inserting Instruments (Balloons) (for example: indicator, controller, I/P converter, PLC, logic box. Note that the category includes interlocks and I/O Rockets)

• 8.4.9: Inserting Flow Elements (for example: venturi, orifice plate, turbine) • 8.4.4: Inserting Nozzles• 8.4.10: Inserting Miscellaneous Symbols (items that do not fit into other categories, for

example vessel jackets, revision triangles, pigtail, hexagon. Note that the category also includes symbols representing equipment of EDL (Equipment Data Location) item type)

• 8.4.11: Inserting Assemblies (Collections of flow diagram elements or dynamic labels that are stored in a library)

Notes• For a new drawing, the first symbols to be positioned are usually major equipment

items, e.g. vessels, pumps, electrical equipment etc. • To check the association between items, where this is not apparent in the Engineering

Explorer, there is a facility provided to find out which nozzles, electrical equipment etc are associated to a vessel, finding out which I/O Rockets are associated to which instrument. See 8.9.4: Show Associations between Items.

• After equipment items are placed on the drawing, they can be re-positioned using the Move options on the item's shortcut menus (on the drawing page and the Engineering Explorer). Items can also be copied using the Copy option on the item's shortcut menus. See 8.7.2: Moving Drawing Objects and 8.7.1: Copying Drawing Objects and Labels.

• Unwanted items can be removed by using the Delete option on the item shortcut menus. See 8.7.6: Deleting Drawing Objects.

• The equipment items can then be linked by pipes.

12.16:6© 2011 AVEVA Solutions Ltd

Page 337: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Where an instrument valve is placed between the end node of one pipe, and the start node of another, this valve may serve as the source and destination of these pipes, as opposed to the pipe nodes, depending on the type of valve that it is.

• Handwheels may be inserted onto instrument valves. • Port valves are inserted in the same way as standard general and instrument valves.• The display of ports on port valves and other symbols can be switched on an off. See

8.3.4: Turning the Display of Ports On and Off.• Project configuration may restrict the insertion of a valve or reducer symbol to pipes of

specified specifications and sizes. See the Symbols pane of the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program.

• Shortcut keys - the INSERT key opens the Symbol List dialog box, the DELETE key deletes the selected objects in the drawing.

6.6 Inserting Unassigned P&ID Database ItemsUnassigned P&ID database items are items (equipment, instruments and pipes) which were created in P&ID Reports and on not yet assigned to a project drawing (refer to AVEVA P&ID Reports documentation for details).

Details of unassigned items can be viewed by selecting the Unassigned node under the AVEVA P&ID Database node of the P&ID Data Grid. Under this node, three further nodes are displayed: Equipment, Instruments and Pipes, beneath all unassigned items are listed.

The P&ID Data Grid provided facilities to place such items on a project drawing, changing them from unassigned to assigned.

The inserted items are automatically labelled with the properties set for them in AVEVA P&ID Reports. The symbol used to represent an equipment item or instrument inserted in this manner is also set in AVEVA P&ID.

See:• Inserting Unassigned P&ID Database Symbols (for inserting unassigned equipment

and instruments)• Inserting Unassigned P&ID Database Pipes

6.7 Inserting Unassigned VPE Workbench Items Unassigned VPE Workbench items are equipment and instrument items in the associated VPE Workbench database that have not yet been placed on a project P&ID. If this facility is in use for a project, the items are listed under the Unassigned node in the Engineering Explorer, from where they can be selected and inserted into drawings - see 8.4: Inserting Symbols.

Whether or not the Unassigned node is displayed is controlled by an option on the 2.3.3: VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

The list of unassigned items is extracted from the VPE Workbench database when a connection to the database is established (see 8.8.7: Connecting to a VPE Workbench Database). After this has taken place, the connection may be discontinued, and the list derived from a snapshot of the database stored in an XML file. The connection should be re-established regularly in order to refresh this list.

Note that since not every item in the database is appropriate for placement on a P&ID, facilities are provided in VPE Workbench to restrict the unassigned items list to consist only

12.16:7© 2011 AVEVA Solutions Ltd

Page 338: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

of appropriate item types. An additional filter may be imposed on item types in AVEVA P&ID, using a dialog accessed from the Engineering Explorer.

The details of unassigned items can be viewed on 4.8: Properties Dialogs While an item is unassigned, no changes may be made to these details. The only exception is that a Symbol Name may be selected for an item that had no Symbol Name assigned to it in the database. This must be done when an unassigned item is inserted if it was not done beforehand.

Once an unassigned item is inserted, it is no longer unassigned and is removed from the list of unassigned items. The properties of such an item may subsequently be edited as required. However, if the tag of such an item is changed, the link between the item on the drawing and the item in the database is broken. The item in the database is therefore regarded as being unassigned again, and the item on the drawing is regarded as a new engineering item.

Note that unassigned items, on insertion, do not inherit drawing sheet attributes (see 6.10.23: Setting Labels to Inherit Values from Drawing Sheet Attributes).

12.16:8© 2011 AVEVA Solutions Ltd

Page 339: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.8 Drawing Pipes and ConnectionsNote: For projects developed using versions of AVEVA P&ID older than AVEVA VPE P&ID

7.2 SP3, an upgrade of the pipes on the project drawings is required. See 2.1: Upgrading Pipes and Symbols from old Projects.

6.8.1 Drawing Pipes and Process LinksVessels and pumps etc. can be connected with pipes (branches).

There are a number of default settings associated with drawing a pipe. The default pipe style, tracing style and end styles can be set, along with whether or not flow arrows, pipe breaks and tracing are to be included automatically.

All these defaults can be set using the Pipeline Group and Signal Line Group of the Home Tab. Pipes can then be placed on the drawing using a button on the same toolbar (see 8.5.1: Drawing Pipes). These defaults can be changed while in the pipe creation process, and the next segment created responds to the new settings.

When a pipe is drawn, the user will be prompted to identify the new pipe as a main pipe, a branch pipe or a trim pipe. If the pipe is a branch or trim pipe, the user must indicate the owning pipe or equipment.

• Process LinksProcess links are branches that will not be labelled with a pipeline tag, for example connections to off-line instruments, and in some cases by-passes. These can be created in any pipe style by using the Process Links button on the pipes toolbar (see 8.5.3: Drawing Process Links). The settings on the Pipe toolbar also affect process links.

A number of factors should be considered when drawing process links if data is to be exported to an XML file in the ISO 15926 schema format. For details, see Guidelines for Drawing Process Links.

When pipes or process links cross, one of the pipes or process links is automatically broken. When a pipe crosses a process link, the process link is broken. If two pipes cross or two process links cross, the break priority (whether the horizontal or the vertical line is broken) is set on the Pipes Configuration Category of the AVEVA P&ID Project Administration program. If automatic pipe breaking is off, a warning will be received each time a pipe or link is drawn over another.

Instrument Process Links, also known as "Legacy" Process Links, are Process Links without the functionality introduced with AVEVA VPE P&ID 7.2 SP3 (the PLK item type) and may be used if required. A specific style for this type of process link can be selected.

Non-"Legacy" Process Links are drawn using the pipe item type (PMA) in the process link pipe style. In other words they will technically be branches between main pipes and offline items. They will therefore have all the functionality of pipes and may be labelled and edited in the same way.

• Pipe Drawing FacilitiesThe following facilities are also provided to help in drawing pipes and process links:

• The pipe style of an existing pipe can also be changed using facilities on the Pipe toolbar (see 8.5.4: Changing Pipe Styles).

• Tracing can also be applied to existing pipes using a button on this toolbar. See 6.8.3: Tracing Lines for more details.

12.16:9© 2011 AVEVA Solutions Ltd

Page 340: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Pipes, and process links can be manually broken, i.e. if they cross vessels (see 8.5.8: Breaking Lines).

• Pipes and branches may be merged into a single pipe/branch (see 8.5.9: Merging Pipes, Branches and Signal Lines).

• Main pipes may be split into two separate main pipes (see 8.5.10: Splitting Pipes and Signal Lines).

• A parts of a main pipe may be split off as a branch of that pipe (see 8.5.11: Splitting off Branches).

• The flow of a pipe may be reversed (see 8.5.12: Reversing Pipe and Signal Line Flows).

• Pipe segments may be added, merged and deleted (see 8.5.13: Adding Pipe and Signal Line Segments, 8.5.14: Merging Pipe Segments and 8.5.15: Deleting Pipe and Signal Line Segments).

• The length of a pipe or process link may be changed (see 8.5.16: Changing the Length of Lines).

• Elbows may be added to a pipe or process link (see 8.5.17: Adding Elbows to a Line).• Pipes can be converted into branches and branches converted into pipes (see 8.5.18:

Changing Pipes to Branches and Branches to Pipes).• A different pipe can be selected as the owner of a branch (see 8.5.19: Changing the

Owning Pipes of Branches).

6.8.2 Drawing Signal Lines The facilities of the Signal Line Group of the Home Tab. is used to draw signal lines. A basic set of signal lines is provided which complies with Instrument Society of America (I.S.A.) standards. The style, thickness and colour of signal lines are project definable.

To add or edit signal line styles, use the Signal Styles Configuration Category of the AVEVA P&ID Project Administration program.

The default set consists of the following signal lines: • Electrical Signal • Pneumatic Signal • Hydraulic Signal• Undefined Signal • Capillary Tube • Electromagnetic or Sonic Signal • Internal System Link (Software or Data Link)

The procedure for drawing signal lines is very similar to that for drawing pipes or process links. The signal line is drawn in the currently selected signal line style. Each section of line, from turning point to the next, is one entity. All signal lines refresh their blocks when an item is inserted, or the signal line is stretched.

The 'current' signal line style can be set using the Signal Lines toolbar.

The Signal Lines toolbar also includes a button which can be used to change the style of existing signal lines. See 8.5.7: Changing Signal Line Styles.

The following facilities are also provided to help in drawing pipes and process links:• Signal lines can be manually broken (see 8.5.8: Breaking Lines).• Sinal lines may be merged into a single pipe/branch (see 8.5.9: Merging Pipes,

Branches and Signal Lines).

12.16:10© 2011 AVEVA Solutions Ltd

Page 341: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Signal lines may be split into two separate signal lines (see 8.5.10: Splitting Pipes and Signal Lines).

• The flow of a signal line may be reversed (see 8.5.12: Reversing Pipe and Signal Line Flows).

• Signal line segments may be added and deleted (see 8.5.13: Adding Pipe and Signal Line Segments and 8.5.15: Deleting Pipe and Signal Line Segments).

• The length of a signal line may be changed (see 8.5.16: Changing the Length of Lines).• Elbows may be added to a signal line (see 8.5.17: Adding Elbows to a Line)

6.8.3 Tracing Lines Tracing may be added to a pipe as it is being drawn, depending on whether or not automatic pipe tracing is on. This is set in the Pipeline Group of the Home Tab. Changing this setting affects pipes drawn subsequently and a pipe that is being drawn when the setting is changed.

When switched On, tracing in the selected style will appear when a new pipe is drawn. The style of tracing is selected by using the Pipe Toolbar.

Lines previously drawn with no tracing can have tracing applied using a button on the Pipe toolbar. See 8.5.5: Applying Tracing to Pipes. Inline fittings are automatically traced around. When a traced pipe is broken, the tracing is broken also.

AVEVA P&ID is supplied with two tracing styles, STEAM and ELEC. To add or edit tracing styles, use the Tracing Configuration Category of the AVEVA P&ID Project Administration program.

6.8.4 Indicating Pipe Flow Flow direction is indicated graphically by flow arrows. These may be placed as a pipe is being drawn, depending on whether or not automatic flow arrows are on. This is set in the Pipeline Group of the Home Tab. Changing this setting affects pipes drawn subsequently and a pipe that is being drawn when the setting is changed.

If arrows need to be added to pipes that have already been drawn, they must be manually inserted (block name ARROWZ - see 8.4: Inserting Symbols). At present there is no built-in facility for rotating flow arrows so they must be rotated manually with a Rotate command. See 8.7.5: Rotating Drawing Objects. The actual direction of flow is only established when pipe labelling is carried out.

6.9 Selecting Multiple Drawing ObjectsThe method used to select multiple drawing objects depends on whether or not the Entity selected is added to the current selection set checkbox on the Drawing Information – Settings Sub-Set of the AVEVA P&ID Project Administration program is checked.

If the checkbox is unchecked (the default setting), to select multiple drawing objects, press the Shift key while selecting each of the objects. If the Shift key is not pressed when an object or objects are selected, any previously selected objects are de-selected.

If the checkbox is checked, it is not necessary to press Shift in order to select multiple objects. Each object is added to the set of selected objects as it is selected. To remove objects from the set of selected objects, press Shift and select them.

12.16:11© 2011 AVEVA Solutions Ltd

Page 342: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.10 Labelling Symbols

6.10.1 General Information At any time during the drawing production cycle, AVEVA P&ID graphical items may have intelligent flow diagram data assigned to them by means of a label. See 8.6: Labelling Symbols and Pipes. Each label consists of a text string with an AVEVA P&ID item type that identifies the type of label it is. Labels are entered using Properties Dialogs, which can be initialised in many ways:

• Selecting the object, clicking the right mouse button and selecting Properties from the menu

• Selecting the Label button from the AVEVA P&ID Properties toolbar, either with an object selected, or subsequently selecting an object.

• Selecting an item in the Explorer, clicking the right mouse button and selecting Properties. This zooms to the item, selects it and displays the Properties dialog.

Note: The current properties of items can be viewed on the drawing page by hovering the cursor over the symbol in question.

The labelling operation has many modes of behaviour depending on the entity/element or group of entities/elements being labelled. It also used to edit standard CAD software text.

The command may operate automatically when a symbol is inserted. This is known as 'auto-labelling'. Auto-labelling for categories of items is switched on and off using the facilities in the Pipeline Group of the Home Tab. Whether or not auto-labelling is on by default is set on the Miscellaneous - Labels Sub-Set of the AVEVA P&ID Project Administration program.

Labels are added on top of the graphics, thus allowing for maximum flexibility in graphical layout and revision of the drawing. This method allows movement, rotation etc. of AVEVA P&ID items to be unrestricted even after labelling has taken place. Labelling must exist for the engineering data to be validated and transferred to VPE Workbench.

Every label has an Item Type which dictates its behaviour in a given situation. A full list of Item Types can be found in the section 9.3: AVEVA P&ID Item Types and Label Types.

Label text is handled intelligently during rotation or reflection to ensure it retains its correct orientation. Any revisions to labels are immediately reflected in the displayed text. Quick rotation of labels is provided, by selecting the label, clicking the right mouse button and selecting rotate from the menu.

The text of labels may either be in the default font select for the project, or in the text style assigned to the label type. Text styles are defined on the Text Styles Configuration Categoryof the AVEVA P&ID Project Administration program, and assigned to label types using the Label Types Configuration Category.

If the On-Line Data Validation checkbox on the Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program is checked, labels are validated as they are entered against project defined lists of allowable values. Labels of a given type must be unique on the drawing. For example two Instrument items cannot have the same label. For further information on validation, see 3.5: Validation.

A facility is provided to bulk edit label fields. See 8.6.30: Globally Editing Labels.

12.16:12© 2011 AVEVA Solutions Ltd

Page 343: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Dynamic Labels Symbols can also be labelled with dynamic labels which consist of selected data from a VPE Workbench project database. See 6.16: Dynamic Labelling.

• Labelling with Data from the P&ID GridAll of the data displayed in the tables in the right-hand window of the P&ID Data Grid may be used to label the drawing. In this way, the drawing may be labelled with data not available using the normal labelling procedures, i.e. with properties of items that are not included in the standard labels.

For details of this procedure see 8.6.22: Labelling with Data from the P&ID Data Grid.

See also 8.6.23: Refreshing P&ID Data Grid Labels.

6.10.2 Setting Text Options The text of labels may either be in the default font select for the project, or in the text style assigned to the label type. Text styles are defined on the Text Styles Configuration Categoryof the AVEVA P&ID Project Administration program, and assigned to label types using the Label Types Configuration Category.

In addition, the height, justification and rotation settings of the text of a label are project configuration options, also set using the Label Types Configuration Category.

These values can be overridden for individual labels using their Properties Dialogs.

6.10.3 Labelling/Editing Non-AVEVA P&ID TextIn order to edit text that was inserted into a drawing before it became an AVEVA P&IDdrawing, use the Labelling procedure.

See 8.6.24: Editing Non-AVEVA P&ID Text.

6.10.4 Label Inheritance from Owning PipesInstrument, inline equipment, valve and line fitting label data may be inherited from the label of the owning pipe. This functionality is configured using the Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Line Fittings Configuration Category of the AVEVA P&ID Project Administration program.

12.16:13© 2011 AVEVA Solutions Ltd

Page 344: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

If it is not clear which pipe is the owning pipe, the List Item Details should be used to identify it.

For details of setting items to inherit pipe data, and to switch this inheritance off if required, see 8.6.31: Setting Symbols to Inherit Label Data from a Manually Selected Pipe and 8.6.32: Switching off Label Data Inheritance from Pipes.

6.10.5 Labelling Equipment Equipment labels must be unique for each drawing produced, i.e., unique per sheet. An equipment label consists of up to either four or six parts, depending on project configuration:

Block

Function

Prefix

Type

Number

Suffix

The names of the parts of the Equipment label can be changed but the order cannot. Block and Function are only used if the project is set to use 6 tag fields for equipment on the Equipment - Settings Sub-Set of the AVEVA P&ID Project Administration program.

12.16:14© 2011 AVEVA Solutions Ltd

Page 345: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

If the Type or Number are left blank, the project defined null character will replace that field, e.g., V-?-2 or ?-100-2. If any null characters are present in equipment labels, the label is not checked for uniqueness against the other equipment labels on that drawing.

Depending on the setup of the associated project configuration options, delimiters will appear automatically when the equipment label is placed, e.g., V, 1000, A will become V-1000-A. Trailing delimiters will be automatically prevented if parts of the equipment label are not used.

In addition to the requirement that each equipment label must be unique on the drawing, the project may be set to require that selected a field or a combination of fields in equipment labels also be unique.

• Equipment With Trim Sometimes additional piping and attached items are supplied by the vendor as being associated with a vessel. These are known as vessel trim. They are attached directly to the vessel at both ends, or to the vessel and a process line. AVEVA P&ID associates trim to a vessel at the labelling stage.

The default "Trim:" prefix, which signifies that trim labelling is present, may be altered on the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program.

See 8.6.3: Labelling Equipment (with or without Trim).

• Electrical Equipment Electrical equipment must be associated with an existing item of ordinary equipment. The procedure for labelling electrical equipment is identical to that for labelling ordinary equipment.

See 8.6.4: Labelling Electrical Equipment.

• Equipment HeadersEquipment may be labelled with a separate equipment header. The header includes the equipment label plus any other required text as entered by the user. If an equipment label is changed, the equipment label in an equipment header is automatically updated.

Whether or not equipment headers are to be underlined on P&IDs is specified on the Equipment - Settings Sub-Set of the AVEVA P&ID Project Administration program.

See 8.6.5 - Adding Equipment Headers..

6.10.6 Labelling General ValvesThe labelling of general valves, e.g., ball valves, gate valves, etc., involves the placement of a tag, and optionally, closure, valve code and size date. This tag data may be inherited from the label of the owning pipe, as set-up on the Pipes - Settings Sub-Set of the AVEVA P&IDProject Administration program. If it is not clear which pipe is the owning pipe, the List Item Details procedure should be used to identify it.

Valve codes can be applied to piping valves; but not to instrument valves. The valve code can be automatically placed according to the entries for the associated project configuration options set in the Valves - Labels Sub-Set of the AVEVA P&ID Project Administration program. The code will automatically place itself in alignment with valve.

A general valve can be labelled as a Special Piping Item (SPP) by the addition of four configurable SPP labels to the valve label.

12.16:15© 2011 AVEVA Solutions Ltd

Page 346: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Valve tags and SPP labels do not have to be unique; it is possible for the valve and special piping item to have the same tag number.

When a valve is inserted into a pipe, the valve will inherit the size of the pipe into which it is inserted. The size of a valve in a process link may be manually increased, but not the size of a valve in a pipe.

If general valves are unlabelled, no warnings or errors are issued on output.

See 8.6.7: Labelling General Valves.

See also 8.6.8: Labelling Port Valves.

• Using Valve Pattern LabelsThe “patterns” facility is used to nominate a valve record, displayed on a drawing, to act as a representative for one or more line fitting item records, which are not displayed, but will be exported on output along with the displayed item.

The AVEVA P&ID Item Type for a pattern label is XPR. It is a good idea to configure all pattern labels to be a set colour, in the Item Types – Standard Sub-Set of the AVEVA P&ID Project Administration program. All users will then instantly recognize pattern labels on drawings that other users have worked on.

Details of valve patterns are edited using the Valve - Patterns Sub-Set of the AVEVA P&ID Project Administration program.

The valve which has been physically drawn on the drawing is known as the substitute item in the pattern; it is expanded on output into all its components which are detailed in this pattern. An extra field is present in the output files. It is called Pattern Item and has an * (asterisk) in it if the item has been defined as a pattern item.

To use the pattern facility, the pattern reference number is allocated when labelling any valve using the Valve Properties Dialogs. See 8.6.7: Labelling General Valves.

All data is validated on output for the pattern items as if they had been drawn on the drawing.

6.10.7 Labelling Inline Fittings (Special Piping Items)When labelling inline fittings and SPPs (Special Piping Items) such as flame traps, duct fittings, expansion bellows, insulation, hoses and strainers, each part of the inline fitting or SPP label can be added or deleted independently of the other parts of the label.

See 8.6.9: Labelling Inline Fittings.

Other line labelling is covered elsewhere. See:

6.10.8: Labelling Pipe Destination Fittings

6.10.20: Labelling Pipe Flags

6.11.6: Adding Pipe Destination Text

6.11.5: Labelling Pipes with Breaks and Inline Breaks

6.11.4: Labelling Pipes with Reducers and Reducing Valves

6.10.8 Labelling Pipe Destination FittingsPipe destination fittings (e.g. end caps) are only labelled with a size and a specification.

12.16:16© 2011 AVEVA Solutions Ltd

Page 347: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

See 8.6.10: Labelling Pipe Destination Fittings.

6.10.9 Labelling Port ValvesPort valves are general (piping) and instrument valves that include distinct ports to which pipes and other symbols may be attached. Unlike the connectors on standard valves, these ports may be labelled, and an identifier and a size allocated to them. The size may be specified by the user, or derived automatically from connected items. Port data is included in exports from P&IDs.

The List Item Details procedure can be used to quickly view the port id's and sizes of a port valve.

Port valves are labelled in the same way as general and instrument valves (the main body of the valve in the case of instrument valves), except that additional fields are provided related to specifying the port sizes.

See 8.6.8: Labelling Port Valves.

For more information on "normal" valve labelling, see:

6.10.6: Labelling General Valves.

6.10.10: Labelling Instrument Valves (Control Valves).

6.10.10 Labelling Instrument Valves (Control Valves)The main body of the valve and/or the balloon can be labelled. An error will be received on output if the balloon label is not present.

Instrument valve label data may be inherited from the label of the owning pipe, as set-up on the Pipes - Settings Sub-Set of the AVEVA P&ID Project Administration program. If it is not clear which pipe is the owning pipe, the List Item Details procedure should be used to identify it.

When labelling the main body of the valve, use the same labelling procedure as for general valves except that the valve code does not apply.

See 8.6.7: Labelling General Valves.

See also 8.6.8: Labelling Port Valves.

When labelling the balloon, use the same labelling procedure as for instruments.

See 8.6.12: Labelling General Instruments.

Any changes to the instrument balloon label positions in the project configuration file will only take effect if labels are removed and replaced. If a labelled control valve is copied, all labelling is removed except the Item Type reference in the balloon e.g., FT.

A descriptor can be included in the label. Descriptors are used within VPE Workbench when assigning VPE Workbench item types to incoming instruments from AVEVA P&ID. For example, a descriptor of Vortex, Magnetic Flow, Coriolis, or Turbine could be used to specifically differentiate between different types of flow transmitters. A restricted choice of item types is available when the descriptor for the instrument is completed.

Instrument label balloons can be moved independently from the instrument.

There is also a facility to bulk edit instrument labels. See 8.6.30: Globally Editing Labels.

12.16:17© 2011 AVEVA Solutions Ltd

Page 348: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.10.11 Labelling General Instruments This category of symbol includes instrument indicators with or without alarms, instrument valve balloons, instruments with I/P converters, and flow elements. General information on the principles of labelling general instruments is given below.

Instrument label data may be inherited from the label of the owning pipe, as set-up on the Pipes - Settings Sub-Set of the AVEVA P&ID Project Administration program. If it is not clear which pipe is the owning pipe, the List Item Details procedure should be used to identify it.

For instructions on labelling general instruments, see 8.6.12: Labelling General Instruments.

There is also a facility to bulk edit instrument labels. See 8.6.30: Globally Editing Labels.

• Label FormatAn instrument label consists of up to either four or six parts, depending on project configuration:

Block

Function

Prefix

Type

Number

Suffix

The names of the parts of the instrument label can be changed but the order cannot. Block and Function are only used if the project is set to use 6 tag fields for instruments on the Instrument - Settings Sub-Set of the AVEVA P&ID Project Administration program.

• Label Positioning The default instrument label positioning is set in the Instrument Label Positions section of the Instruments - Labels Sub-Set of the AVEVA P&ID Project Administration program. If different label positions are needed for different types of instrument balloons, the default positioning can be overridden by selecting the Instrument Label Positional data option in the List of Values Configuration Category.

• Descriptors A descriptor can be included in the label. Descriptors are used within VPE Workbench when assigning VPE Workbench item types to incoming instruments from AVEVA P&ID. For example, a descriptor of Vortex, Magnetic Flow, Coriolis, or Turbine could be used to specifically differentiate between different types of flow transmitters. A restricted choice of item types is available when the descriptor for the instrument is completed.

• Label Uniqueness Each instrument label must be unique on the drawing. In addition, the project may be set to require that selected fields or combination of fields in instrument labels must also be unique.

Adding Alarm Labels

If the item is a remote instrument, a prompt will be received to add up to four alarm labels, e.g., H - high and L - Low.

12.16:18© 2011 AVEVA Solutions Ltd

Page 349: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Automatic Suffix Assignment for Duplicate Instrument Tags Instruments can be assigned the same tag number, provided that separate suffixes are attached to the tag number of each instrument. The system automatically prompts for the assignation of these suffixes.

• Labelling Instruments with I/P Convertors The presence of an I/P convertor on an instrument precludes the entry of a descriptor label.

• Effects of Import Allowed or Disallowed If the project configuration has been set in the AVEVA P&ID Project Administration program (using the Loop numbers from VPE Workbench checkbox on the Instruments - Labels Sub-Set) to allow import of loop numbers etc., the only visible difference when labelling instruments is that a Prefix, Loop number or Suffix (or equivalent field names) cannot be entered. They will appear greyed out in the Properties Dialogs.

If the import of loop numbers is disallowed, a prompt will be received to enter a Prefix, Loop Number and Suffix when labelling instruments.

Refer to 7.1: Exporting Data to an AVEVA P&ID Reports Database for information on what happens when externally generated loop numbers and I/O information is imported into AVEVA P&ID.

• Flow Elements The flow element symbol category typically includes orifice plates, flow restrictions, venturi, flow straighteners and turbine meters. They all have label balloons attached. It is not possible to pick the flow element itself for labelling - the balloon must be chosen. Labelling is then as for ordinary instruments. No alarm labels are permitted. There are no associated project configuration options.

For information on further aspects of labelling instruments see 6.10.12: Labelling General Instruments - Using Instrument Pattern Labels and 6.10.13: Labelling General Instruments - Panel Reference Labels.

• Instrument LoopsInstrument loops may be defined, to which instruments may subsequently be added. See Creating Instrument Loops for details.

Instruments in a loop can inherit properties from the loop they are assigned to, as set using in the Instruments - Settings Sub-Set of the AVEVA P&ID Project Administration program.

12.16:19© 2011 AVEVA Solutions Ltd

Page 350: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.10.12 Labelling General Instruments - Using Instrument Pattern LabelsThe "patterns" facility is used to nominate an instrument record, displayed on a drawing, to act as a representative for further instrument records, which are not displayed, but will be exported on output along with the displayed item.

A simple example of this is a Flow Indicator (FI) which could consist of the displayed Flow Indicator (FI) itself, which also represents a Flow Transmitter (FT) and a Flow Element (FE).

The AVEVA P&ID Item Type for a pattern label is XPR. It is a good idea to configure all pattern labels to be a set colour, in the Item Types - Standard Sub-Set of the AVEVA P&IDProject Administration program. All users will then instantly recognize pattern labels on drawings that other users have worked on.

Details of patterns are edited using the Instruments - Patterns Sub-Set of the AVEVA P&IDProject Administration program.

The instrument which has been physically drawn on the drawing is known as the substitute item in the pattern; it is expanded on output into all its components which are detailed in this pattern. An extra field is present in the output files. It is called Pattern Item and has an * (asterisk) in it if the item has been defined as a pattern item.

To use the pattern facility, the pattern reference number is allocated when labelling any instrument (including remote and instrument valves) using the Instrument Balloon Properties Dialogs. See 8.6.12: Labelling General Instruments.

A pattern can only be created for instruments with the same tag/loop number. This is because the tag/loop number is inherited from the substitute item. Suffixes must be used correctly to distinguish between identically labelled instruments. The Loop Number is read from the drawing and if no loop number has been assigned, a dummy tag, e.g., [234]34, will be exported. The grid reference for all pattern items is the same as for the substitute item.

If VPE Workbench outputs any tag numbers (loop numbers) back to the drawing via the bi-directional link, data on pattern instruments is automatically excluded from the transfer as the instruments do not physically exist on the drawing.

12.16:20© 2011 AVEVA Solutions Ltd

Page 351: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

All data is validated on output for the pattern items as if they had been drawn on the drawing.

6.10.13 Labelling General Instruments - Panel Reference LabelsPanel Reference Labels are used when an instrument or instrument valve is to be panel mounted rather than, for example, rack or field-mounted. Many instruments/equipment items can be assigned to one panel reference. This instrument/panel association is exported to VPE Workbench.

The panel reference consists of a Prefix, Type, Loop Number and Suffix. (The panel type can be selected as instrument or equipment type.) The four components of the label are positioned automatically according to the associated project configuration options.

The panel reference is added when labelling the instrument. See 8.6.12: Labelling General Instruments.

6.10.14 Labelling System I/O Connections, Interlocks and Logic BoxesSystem I/O Connections, Interlocks and Logic Boxes are labelled with an item reference, but with no other data. Duplicate labels are permitted.

See 8.6.13: Labelling System I/O Connections, Interlocks and Logic Boxes.

6.10.15 Labelling I/O RocketsI/O Rockets are used to assign single or multiple I/O (input/output) data against instruments or equipment. When I/O rockets are being used, the I/O data entered in VPE Workbench for those tagged items passes back onto the P&ID in a read-only form when AVEVA P&ID is initialised. I/O rockets can either be associated with an instrument, or can themselves be tagged as instruments.

See 8.6.14: Labelling I/O Rockets.

• Label Positioning The default instrument label positioning is set in the Instrument Label Positions section of the Instruments - Labels Sub-Set of the AVEVA P&ID Project Administration program. The default positioning can be overridden by selecting the Instrument Label Positional data option in the List of Values Configuration Category.

• Imported I/O Data There is no project configuration option to determine whether or not I/O rockets will import I/O address data from an external source. The data, if available, is automatically imported when AVEVA P&ID is initialised.

See 7.1: Exporting Data to an AVEVA P&ID Reports Database.

6.10.16 Labelling Nozzles Nozzles are placed on vessels and on other items of equipment. When labelling a nozzle, a nozzle tag must be placed. If no nozzle size label is applied and a pipe is attached to the nozzle, the nozzle will inherit the pipe size on output. The nozzle may have a different size to the pipe and hence be an enlarging or reducing nozzle.

12.16:21© 2011 AVEVA Solutions Ltd

Page 352: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Duplicate nozzle labels are not permitted on a vessel. An error message is displayed if this is attempted. Duplicate nozzles are permitted on different vessels, i.e., vessel V-100 and vessel V-200 may both have a nozzle labelled N1.

If warnings about nozzles which have labels missing are not required when performing an output, ensure that the Nozzle error balloon placement checkbox on the Label Types Configuration Category on the AVEVA P&ID Project Administration program is checked.

If nozzle sizes are to cascaded onto connecting pipes, check the Cascade Nozzle to Pipe checkbox on the Nozzles - Settings Sub-Set . To connect a nozzle to a pipe, so that sizes can be cascaded, see 8.5.20: Connecting Pipes to Nozzles and Equipment. To disconnect a nozzle from a pipe if cascading is not required for a particular pipe and nozzle, see 8.5.21: Disconnecting Pipes from Nozzles and Equipment

If nozzles are to be labelled using an automatically incrementing number, check the Increment Nozzle Sequence checkbox on the Nozzles - Labels Sub-Set.

If nozzles labels are to automatically include a prefix, enter this prefix in the Nozzle Prefix field on the Nozzles - Labels Sub-Set.

See 8.6.6: Labelling Nozzles.

6.10.17 Labelling Miscellaneous ItemsMiscellaneous items include items such as Vessel Jackets. These cannot be labelled using the normal labelling facilities. It is possible however to attach notes to them. See 8.6.29: Adding Notes to Items.

6.10.18 Labelling AssembliesGraphical assemblies are reduced to their component AVEVA P&ID items on insertion. Items in an assembly should be labelled as individual items.

6.10.19 Labelling Clouds Clouds cannot be directly labelled using the normal labelling facilities, nor can they have notes added. Revision triangles should be inserted near the clouds (see 8.4: Inserting Symbols). The revision triangles should be then labelled using.

See 8.6.15: Labelling Revision Triangles.

6.10.20 Labelling Pipe FlagsLabelling Pipe Flags (i.e. off-sheet or page connectors) with their correct destination drawing number is crucial for the correct resolution of pipes across multiple P&IDs. If using sheet numbers they must be included as part of the pipe flag label.

Pipe flags may be labelled from a list of drawings on which valid and available source/destination pipe flags are located. If labelled in this way, a pipe flag may be hyperlinked, i.e. Ctrl-clicking on it, or selecting the Open Target Drawing option from the flag's right-click menu, will open the drawing on which connected pipe flag is located.

Pipe flag labels can be deleted by selecting the Delete option from The Drawing Page menu for the label.

If a pipe flag is to be used as well as pipe destination text, the pipe destination text must be used to record the actual destination. A note should be entered in the flag to refer to the pipe destination text. If an attempt is made to label the pipe flag with the destination as well as

12.16:22© 2011 AVEVA Solutions Ltd

Page 353: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

using pipe destination text, there will be two recorded destinations, leading to confusion when data is output.

Pipe flags can also be labelled with the grid reference of the pipe flag on the source/destination drawing.

See 8.6.18: Labelling and Connecting Pipe Flags.

6.10.21 Labelling Revision TrianglesThe labelling procedure can be used to place the revision text associated with the revision triangles. When a revision triangle is labelled, it is automatically labelled with a letter or number which is a reference to the revision text. This number can be changed if required.

If grid referencing is on, a grid reference can be placed when a triangle is inserted, to show the location of the actual change. This grid reference is not maintained as the drawing is rearranged.

Revision triangle data cannot be edited once it has been placed. The revision number inside the triangle is associated with the triangle and neither can be deleted separately. Instead, they must be deleted as a single item by selecting the Delete option from The Drawing Pageor Engineering Explorer menus for the item.

Revision text is also be deleted as a single item.

If an attempt is made to label two revision triangles with the same revision number/letter, or if the revision number, reviser and description are not completed, an error message will be received.

The Label offset from symbol origin fields in the Miscellaneous - Labels Sub-Set of the AVEVA P&ID Project Administration program determine the position of the automatic revision label relative to the triangle symbol's insertion point.

See 8.6.15: Labelling Revision Triangles.

6.10.22 Setting Properties Sheet fields to inherit previously entered valuesA project can be configured so that a value entered in a field in a Properties dialog is "inherited" by the same field when that Properties dialog is accessed again when labelling another, previously unlabelled, item of that type.

For example, the functionality is switched on for equipment Prefix field, and an equipment item is labelled with a value of "20". The next time an equipment item is labelled for the first time, when the Properties dialog for this item is opened, the Prefix field will automatically be completed with the value "20". This can be replaced by another value if required. This new value will then be the "inherited" value for the equipment Prefix field.

Select the Property dialog fields to which this function is applied using the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program.

6.10.23 Setting Labels to Inherit Values from Drawing Sheet AttributesThe values of labels may be inherited from the sheet attributes entered on the Advanced Drawing Properties dialog. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design area. The inheritance facility enables all items to inherit these common values. The labels of items that do not

12.16:23© 2011 AVEVA Solutions Ltd

Page 354: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

share these common values may subsequently be edited manually using their properties sheets.

Values inherited from sheet attributes can be hidden, i.e. though they are part of labels and will be included in any exports of P&ID data, they are not displayed on P&IDs. Whether or not a value is hidden is set up on a field-by-field basis.

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

Note that sheet attribute fields can be linked to lists of values, so that only values from those lists can be entered into the sheet attribute fields. This is also set up using the Drawing Information – Settings Sub-Set.

Establish inheritance between item label and sheet attribute fields, and specify whether or not inherited values are to be hidden using the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Line Fittings Configuration Category of the AVEVA P&ID Project Administration program.

Note that if an instrument or valve label is set to inherit from the owning pipe, this takes priority over sheet attribute inheritance.

Also note that unassigned P&ID Database items and unassigned VPE Workbench items, on insertion, do not inherit drawing sheet attributes. See Inserting Unassigned P&ID Database Items and 6.7: Inserting Unassigned VPE Workbench Items.

• Changing Inherited Values The following points should be considered when editing inherited values both at drawing sheet and item level:

• When sheet attribute inheritance is first activated, any existing pipe values will not be overwritten with sheet attribute values. Existing values for non-pipe labels will be overwritten. All null values for all item labels will be overwritten.

• If a sheet attribute value is changed, all pipe label values that match the old attribute value are set to the new attribute value, regardless of whether that value was inherited or entered manually. For example, if the design area sheet attribute is changed from A to B, all pipe label fields set to inherit from this sheet attribute that were set to A are also changed to B.

• If a sheet attribute value is changed, all non-pipe label values are changed to the new value, as long as that value was inherited. If the value was entered manually, it will not be subsequently affected by changes to sheet attribute values. To re-establish inheritance for a non-pipe label that has been changed manually, delete the label and re-label the item.

• If an item label field is re-set after inheritance to inherit from a different sheet attribute field, any existing inherited values will behave as if the sheet attribute value had simply been changed, as described above.

• All null values in fields that are set to inherit from sheet attributes will be updated when sheet attribute values are changed.

• If a label field that must be populated from a list of valid values is set to inherit from a drawing sheet attribute field, that drawing sheet attribute field must also be populated from that same list of values.

• If a sheet attribute value that was set to be hidden is changed, those items that were labelled with the previous value will still have that part of their labels hidden, even though it is no longer an inherited value. To "unhide" that part of their labels, open the Properties dialog for each item andpress the OK button.

12.16:24© 2011 AVEVA Solutions Ltd

Page 355: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.10.24 Inserting Symbols with Labels Equipment and Inline Equipment labels may automatically have a symbol placed with them when they are inserted. For example, they may be placed in a box, or in a flag symbol.

Create the symbols required for this purpose in the normal way using AutoCAD. Ensure that the symbol is placed in the \PMETSYM or \PIMPSYM project symbol directory as appropriate.

This functionality is switched on and off for each item category, the required symbols selected, and the offsets from the labels specified using the Equipment - Labels Sub-Set of the AVEVA P&ID Project Administration program.

See 8.6.3: Labelling Equipment (with or without Trim).

6.10.25 Automatic TaggingThe tags of valves and the number components of pipe, instrument and equipment tags may be set to be completed automatically.

Note: If this facility is in used, valve tags and the number fields of pipe, instrument and equipment tags should not be set to (see 6.10.23: Setting Labels to Inherit Values from Drawing Sheet Attributes).

This facility is turned on when the format for automatic valve tags is defined using thePipes - Automatic Tag Format Sub-Set, Instruments - Automatic Tag Format Sub-Set, Equipment - Automatic Tag Format Sub-Set, Valves - Automatic Tag Format Sub-Set of the AVEVA P&ID Project Administration program.

If automatic tagging is in use for pipe, instrument and equipment tags, the number component of such items is automatically completed with an automatically incrementing number in a format defined using the above panes.

Automatic valve tags may also include an automatically incremented number.

The automatically incremented number for a type of item may be reset to 0 for a project using a button on the relevant AVEVA P&ID Project Administration program pane.

Automatic valve tags may include user-defined attributes of valves, as selected when the tag format is defined. The available properties for the format are defined in a DataSet which must be set up for this purpose (see Defining Valve Tag Properties for Automatic Valve Tagging).

Automatic valve tags may also include selected attributes from owner pipes.

If the facility is in use, the relevant fields on the Properties Dialogs are automatically completed when items are labelled. These values may be replaced by manual entry if required.

Existing items that were not automatically labelled may be re-labelled with tags in the automatic tag format. See 8.6.26: Replacing Tags with Tags in the Automatic Tag Format. Note that items that were automatically labelled and then manually changed are not re-labelled by this procedure.

12.16:25© 2011 AVEVA Solutions Ltd

Page 356: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.11 Labelling Pipes

6.11.1 General Information Pipes, branches, trim pipes, reducers and breaks can all be labelled. See 8.6: Labelling Symbols and Pipes. Several pipe labels may be placed on one pipe by a single use of this command. It is not possible to label across equipment when labelling a pipe. Labels are entered using Properties Dialogs.

The command may operate automatically when a pipe is drawn. This is known as auto-labelling'. Auto-labelling for pipes is switched on and off using the facilities in the Pipeline Group of the Home Tab.

Whether or not auto-labelling is on by default is set on the Miscellaneous - Labels Sub-Setof the AVEVA P&ID Project Administration program.

Facilities are provided to check the association between an existing label and a pipe, if this is not clear on the drawing. See 8.9.4: Show Associations between Items.

The pipe with which a pipe label is associated can be changed if required. See 8.6.28: Changing the Association of a Pipe Label.

Note: The current properties of items can be viewed on the drawing page by hovering the cursor over the symbol in question.

• Pipe Label Fields A pipe label consists of the data entered into between three and fifteen fields, depending on the project configuration (set using the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program). While the format of a label is fixed, it is possible to limit the number of fields that are actually displayed on a drawing by switching off fixed label formatting (see 6.11.2: Label Display Options).

• Reformatting Existing Pipe Labels If the project configuration option dictating the order and/or number of the pipe label fields is altered, existing labels are reformatted automatically. This takes place when AVEVA P&ID is next initialised. Fields that have been added to the project configuration are populated with the default null character. Fields that have been removed from the project configuration are deleted.

12.16:26© 2011 AVEVA Solutions Ltd

Page 357: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Nodes When a pipe is labelled, 'nodes' are placed at the start and end of each pipe. All the pipe data is held at the start node.

At any time, a pipe route may be changed by moving these nodes. Revision time is minimised, as only the nodes need be moved and not whole associations of pipes, equipment etc. All pipe label field data is held on the start node.

• Main Pipe Labels In the case of pipes that have multiple labels, one of these labels may be set as the "main pipe label". See 8.6.27: Setting a Pipe Label as the Main Label. By default, the properties of the pipe at the start node are presented as the "main" properties of the pipe on export. This option sets the label of another part of the pipe, which may be more representative of the properties of the pipe as a whole, to be the "main" properties.

The main pipe label is displayed in a different colour on the P&ID, and the part of the pipe that has been labelled as the "main" pipe label is displayed at the top of the hierarchy of a pipe and its branches in the Engineering Explorer. If no main pipe label has been set, the pipe start node properties assume this position by default.

• Reducer and Other Pipe Feature Labels In addition to the labels of the pipes themselves, reducers and inline breaks can be labelled. Examples of inline breaks include Specification Changes, Area Breaks, Insulation Breaks, Trace Breaks and Paint Breaks.

• Dynamic Labels Pipes can also be labelled with dynamic labels that consist of selected data from a VPE Workbench project database. See 6.16: Dynamic Labelling.

• Labelling with Data from the P&ID GridAll of the data displayed in the tables in the right-hand window of the P&ID Data Grid may be used to label the drawing. In this way, the drawing may be labelled with data not available using the normal labelling procedures, i.e. with properties of items that are not included in the standard labels.

For details of this procedure see 8.6.22: Labelling with Data from the P&ID Data Grid.

See also 8.6.23: Refreshing P&ID Data Grid Labels.

12.16:27© 2011 AVEVA Solutions Ltd

Page 358: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Label Uniqueness Each pipe label must be unique on the drawing. In addition, the project may be set to require that selected fields or combination of fields in pipe labels must also be unique.

• Associated Project Configuration Options The boilerplate text labelling the three project definable fields which appear on the pipe labelling Properties dialog are specified in the Pipes - Labels Sub-Set of the AVEVA P&IDProject Administration program.

Pipe label format is also established in this pane.

The character used as the field delimiter in pipe labels is specified in the Delimiter field. If this delimiter is to follow the area code field, the Delimiter after area field checkbox must be checked, otherwise the size of the space to be left after the area code field must be specified in the Number of characters field.

The label fields which are to be checked for uniqueness are specified in the Unique Validation field.

6.11.2 Label Display Options

• Text Options The text of labels may either be in the default font select for the project, or in the text style assigned to the label type. Text styles are defined on the Text Styles Configuration Categoryof the AVEVA P&ID Project Administration program, and assigned to label types using the Label Types Configuration Category.

In addition, the height, justification and rotation settings of the text of a label are project configuration options, also set using the Label Types Configuration Category.

These values can be overridden for individual labels using their Properties Dialogs.

• Non-Standard (Single Property) Label Format Although the format of a label is fixed by the project configuration, it is possible to specify which part of a label is actually displayed on a drawing. This is achieved by selecting single property label formatting while labelling a pipe. For example, it may be required to have displayed only the specification part or only the number part of a label. It is possible to combine both fixed and non-standard label format on the same pipe, if multiple labels are applied.

If fixed label formatting is to be used, the Fixed Pipe Label Format checkbox on the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program must be checked. This controls the default setting of the Pipe Label Type field in the Pipeline Properties Dialogs.

Note: Once a format has been chosen and the pipe label placed on the drawing, the format cannot be modified. The label must be deleted and reapplied.

12.16:28© 2011 AVEVA Solutions Ltd

Page 359: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Split Label Format Split Label Formatting is the placing of some fields of a pipe label above the pipe and the remainder below the pipe. Split Label Formatting is controlled by three associated project configuration options as discussed below.

The Split After Field field on the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program is used to select which field in the pipe format to split on. The number entered here determines how many fields to count from the left of the pipe label before the split occurs.

Note: Do not confuse these numbers with the order numbers allocated to fields in the project configuration for pipe labels.

For example, if the entry is 3, the pipe label will display with the first 3 fields above the pipe, and the remaining fields below it.

When split label formatting is turned on, the Y offset above line and Y offset below line fields are responsible for setting the offset from the label point picked when placing the pipe label. If the point picked is directly on the pipe, the Y offset distances are equal and the text justification for the pipe label is set to MC (Middle Centre), the pipe label will appear as shown above.

12.16:29© 2011 AVEVA Solutions Ltd

Page 360: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Note: The pipe label justification is BC (Bottom Centre) by default in the project configuration file.

It is possible to change the pipe label display from single label display to split pipe label display or vice versa.

Note: If the configuration changes from single pipe label display to split pipe label display, the split pipe label configuration options are applied using the insertion point and display attributes of the original single pipe label as a reference. It is therefore possible that when the original single pipe label is too far from the pipe, the second pipe label may overlap the pipe and a manual displacement of the split pipe label needs to take place.

• Null Characters The default null character (e.g. ?) can be selected for all or for specific pipe label fields, if pipe data is not yet available. The label will then appear with the null character as defined by the project configuration. This is the only application of this facility.

For example, if the null character were used for each digit of the area number, pipe label 2"-SW-2001-S1A-5L would appear as 2"-SW-??01-S1A-5L.

Labelling pipes with null characters and then loading them into VPE Workbench has implications for uniqueness of pipe labels, which need to be considered. For further information, refer to AVEVA P&ID Technical Support.

6.11.3 Labelling Pipes Any number of labels can be placed on a pipe. Each segment of a pipe may be labelled, and pipe labels can be placed on either side of reducers and breaks as required. All or a part of a pipe label can be placed as required.

Changes made to pipe properties are automatically reflected by all the labels of the pipe. For example, changes to the pipe size are automatically cascaded along the pipe flow, updating all pipe labels upstream and downstream. Reducer and inline break properties and labels are also automatically updated (see 6.11.4: Labelling Pipes with Reducers and Reducing Valves and 6.11.5: Labelling Pipes with Breaks and Inline Breaks for more information).

Nozzle sizes may automatically be cascaded onto connected pipes, depending on the setting of the Cascade Nozzle to Pipe checkbox on the Nozzles - Settings Sub-Set of the AVEVA P&ID Project Administration program.

Owned branches are not affected by size changes of parent pipes.

• Trim PipesA trim pipe is a pipe which forms part of a vessel's associated group of elements. The pipe may or may not be visibly connected to the vessel with which it is to be associated, and can be created in any pipe style. The vessel must already be labelled with a trim label before proceeding with the trim pipework. Trim pipes do not receive a full pipe label, simply a size, but inherit their other fields from the Trim label. A vessel can have multiple trim labels with trim pipes associated to each.

The Trim Label Prefix field on the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program is used to specify the text prefix to the trim identifier in a trim label. Whenever a trim label is created on a vessel, this word appears in front of the main label.

12.16:30© 2011 AVEVA Solutions Ltd

Page 361: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

See 8.6.17: Labelling Pipes.

• Pipe GroupsPipes may be added to a pipe group created reporting purposes (see Creating Pipe Groups). If a pipe has been added to a group, details of the group are added to the properties of the pipe.

The pipe groups that may be created are specified in a DataSet (see Defining the Pipe Groups DataSet) which is defined using the User Defined Attributes - DataSet Sub-Set of the AVEVA P&ID Project Administration program.

6.11.4 Labelling Pipes with Reducers and Reducing ValvesSee 8.6.19: Labelling Reducers and 8.6.7: Labelling General Valves.

If a reducer or reducing valve is inserted into a labelled pipe, both upstream and downstream sizes are inherited from the label of the pipe segment that the symbol was inserted into. The properties of the reducer or reducing valve must then be edited so that the upstream and downstream sizes are different.

If reducer upstream and downstream pipe sizes are identical, and error message is displayed. Upstream and downstream sizes may be the same for reducing valves.

If the size properties of a reducer or reducing valves are changed, the size of the pipe is automatically changed as appropriate. For example, if the upstream size of a reducer is changed, the size of the pipe upstream from the reducer is also changed to reflect this. If there was a reducer upstream of the upstream pipe segment, its downstream size property would be automatically changed as well.

In the same way, changes made to the size properties of a pipe segment are automatically applied to reducers and reducing valves at either end of that segment. For example, if the size of a pipe segment downstream of a reducer is changed, the downstream size property of that reducer is also changed to reflect this.

If a reducer or reducing valve is deleted, the pipe segment that the symbol was inserted into adopts the size of the segment that was upstream of the deleted symbol.

6.11.5 Labelling Pipes with Breaks and Inline BreaksSee 8.6.20: Labelling Breaks and Inline Breaks.

Breaks can exist either at pipe boundaries or inline, within a pipe run. A Break signifies a change in specification, area, insulation or tracing from one pipe, or one segment of a pipe, to the next.

For breaks at pipe boundaries, there will be a different line number on each side of the break. An inline break is within a pipe, and therefore the pipe number is the same either side of the break.

A single break symbol can be labelled with multiple labels, signifying that the symbol represents more than one type of break, for example, where a trace break and an insulation break occur at the same point.

• Labelling BreaksThe procedure for labelling inline breaks and breaks at pipe boundaries is the same.

12.16:31© 2011 AVEVA Solutions Ltd

Page 362: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

The upstream and downstream values of a break are initially blank. They are not inherited from the labels of the pipe segments on either side of the break.

As required, enter the upstream and downstream values of the break to reflect the change(s) in properties from one side of the break to the other. Only enter the values for those properties that are different.

The entered upstream and downstream values must be different. Values that are left blank will not label the break.

If the properties of a break are changed, the properties of the pipe are automatically changed as appropriate. For example, if the upstream area property of a break is changed, the area property of the pipe upstream from the break is also changed to reflect this. If there was a break upstream of the upstream pipe segment, its downstream area property would be automatically changed as well.

In the same way, changes made to the properties of a pipe segment are automatically applied to breaks at either end of that segment. For example, if the area of a pipe segment downstream of a break is changed, the downstream area property of that break is also changed to reflect this.

Note that deleting a break symbol will not result in the change in properties being removed. Breaks are indicators of such changes only (unlike reducers).

6.11.6 Adding Pipe Destination TextPipe destination text may be added only to pipes which are already labelled. This type of text can be used for situations such as labelling pipes which end in mid-air. For example, a pipe expelling steam may be labelled, 'To Atmos'. Destination text may also be placed on a start node, if desired.

It should be noted that when VPE Workbench is being used, destination text must be limited to 32 characters. An automatic carriage return is placed at the end of each line of text and this should be included when counting how many characters have been used.

If a pipe flag is to be used as well as pipe destination text, the pipe destination text must be used to record the actual destination. A note should be entered in the flag to refer to the pipe destination text. If an attempt is made to label the pipe flag with the destination as well as using pipe destination text, there will be two recorded destinations, leading to confusion when data is output.

See 8.6.21: Adding Pipe Destination Text.

6.11.7 Modifying Pipe Label Fields and Cascading Changes Through a Pipe RunCascading preserves data consistency across pipe branch networks and over pipe boundaries.

When the properties of parent pipe label are edited, any changes to these properties may immediately be reflected in the labelling of the branches off that pipe.

If required, cascading to pipe branches may be disabled for specified fields on the Pipes - Settings Sub-Set of the AVEVA P&ID Project Administration program. Note however that fields specified for unique validation (see 6.13.3: Label Uniqueness Validation) will still be cascaded regardless of these settings.

Changes of size or spec are also cascaded onto other pipes which are butted end-on to the edited branches, with spec break and reducer, and reducing valves positions being taken

12.16:32© 2011 AVEVA Solutions Ltd

Page 363: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

into account. Reducers and reducing valves behave intelligently throughout changes that affect pipe sizes.

An alert box appears asking the users whether they wish to cascade the data change onto the highlighted pipe. If the user accepts by selecting 'OK', the changes cascade through.

Changes to pipe properties can also be propagated to other pipes connected via linked pipe flags. See Propagating Changes to Pipe Properties.

6.11.8 Setting Properties Sheet fields to inherit previously entered valuesA project can be configured so that a value entered in a field in a Properties dialog is "inherited" by the same field when that Properties dialog is accessed again when labelling another, previously unlabelled, item of that type.

For example, the functionality is switched on for equipment Prefix field, and an equipment item is labelled with a value of "20". The next time an equipment item is labelled for the first time, when the Properties dialog for this item is opened, the Prefix field will automatically be completed with the value "20". This can be replaced by another value if required. This new value will then be the "inherited" value for the equipment Prefix field.

Select the Property dialog fields to which this function is applied using the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program.

6.11.9 Setting Labels to Inherit Values from Drawing Sheet AttributesThe values of labels may be inherited from the sheet attributes entered on the Advanced Drawing Properties dialog. The values entered for these sheet attributes may be values that are common to many items on the drawing, for example the design area. The inheritance facility enables all items to inherit these common values. The labels of items that do not share these common values may subsequently be edited manually using their properties sheets.

Values inherited from sheet attributes can be hidden, i.e. though they are part of labels and will be included in any exports of P&ID data, they are not displayed on P&IDs. Whether or not a value is hidden is set up on a field-by-field basis.

Sheet attribute field names are set up using the Drawing Information - Settings Sub-Set.

Note that sheet attribute fields can be linked to lists of values, so that only values from those lists can be entered into the sheet attribute fields. This is also set up using the Drawing Information – Settings pane.

Establish inheritance between item label and sheet attribute fields, and specify whether or not inherited values are to be hidden using the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Line Fittings Configuration Category of the AVEVA P&ID Project Administration program.

Note that if an instrument or valve label is set to inherit from the owning pipe, this takes priority over sheet attribute inheritance.

Also note that unassigned items, on insertion, do not inherit drawing sheet attributes. See 6.7: Inserting Unassigned VPE Workbench Items.

12.16:33© 2011 AVEVA Solutions Ltd

Page 364: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• Changing Inherited Values The following points should be considered when editing inherited values both at drawing sheet and item level:

• When sheet attribute inheritance is first activated, any existing pipe values will not be overwritten with sheet attribute values. Existing values for non-pipe labels will be overwritten. All null values for all item labels will be overwritten.

• If a sheet attribute value is changed, all pipe label values that match the old attribute value are set to the new attribute value, regardless of whether that value was inherited or entered manually. For example, if the design area sheet attribute is changed from A to B, all pipe label fields set to inherit from this sheet attribute that were set to A are also changed to B.

• If a sheet attribute value is changed, non-pipe label values are not changed to the new value, whether or not they were inherited. Changes to sheet attribute values only affect items labelled subsequently.To re-establish inheritance for a non-pipe label that has been changed manually, delete the label and re-label the item.

• If an item label field is re-set after inheritance to inherit from a different sheet attribute field, any existing inherited values will behave as if the sheet attribute value had simply been changed, as described above.

• All null values in fields that are set to inherit from sheet attributes will be updated when sheet attribute values are changed.

• If a label field that must be populated from a list of valid values is set to inherit from a drawing sheet attribute field, that drawing sheet attribute field must also be populated from that same list of values.

• If a sheet attribute value that was set to be hidden is changed, those items that were labelled with the previous value will still have that part of their labels hidden, even though it is no longer an inherited value.

To "unhide" that part of their labels, open the Properties dialog for each item and press the OK button.

6.11.10 Inserting Symbols with Labels Pipe labels may automatically have a symbol placed with them when they are inserted. For example, they may be placed in a box, or in a flag symbol.

Create the symbols required for this purpose in the normal way using AutoCAD. Ensure that the symbol is placed in the \PMETSYM or \PIMPSYM project symbol directory as appropriate.

This functionality is switched on and off for each item category, the required symbols selected, and the offsets from the labels specified using the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program.

See 8.6.17: Labelling Pipes.

6.11.11 Automatic TaggingThe tags of valves and the number components of pipe, instrument and equipment tags may be set to be completed automatically.

Note: If this facility is in used, valve tags and the number fields of pipe, instrument and equipment tags should not be set to (see 6.10.23: Setting Labels to Inherit Values from Drawing Sheet Attributes).

12.16:34© 2011 AVEVA Solutions Ltd

Page 365: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

This facility is turned on when the format for automatic valve tags is defined using thePipes - Automatic Tag Format Sub-Set, Instruments - Automatic Tag Format Sub-Set, Equipment - Automatic Tag Format Sub-Set, Valves - Automatic Tag Format Sub-Set of the AVEVA P&ID Project Administration program.

If automatic tagging is in use for pipe, instrument and equipment tags, the number component of such items is automatically completed with an automatically incrementing number in a format defined using the above panes.

Automatic valve tags may also include an automatically incremented number.

The automatically incremented number for a type of item may be reset to 0 for a project using a button on the relevant AVEVA P&ID Project Administration program pane.

Automatic valve tags may include user-defined attributes of valves, as selected when the tag format is defined. The available properties for the format are defined in a DataSet which must be set up for this purpose (see Defining Valve Tag Properties for Automatic Valve Tagging).

Automatic valve tags may also include selected attributes from owner pipes.

If the facility is in use, the relevant fields on the Properties Dialogs are automatically completed when items are labelled. These values may be replaced by manual entry if required.

Existing items that were not automatically labelled may be re-labelled with tags in the automatic tag format. See 8.6.26: Replacing Tags with Tags in the Automatic Tag Format. Note that items that were automatically labelled and then manually changed are not re-labelled by this procedure.

12.16:35© 2011 AVEVA Solutions Ltd

Page 366: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.12 Adding User-Defined Attributes User-defined Attributes (UDAs) can be defined in two ways:

• Attributes may be added to symbols and pipes using the standard AutoCAD Attribute Definition dialog, accessed from the Symbol Editor. Lists of valid values for these attributes can then be selected using the User Defined Attributes - UDA List of Values Sub-Set of the AVEVA P&ID Project Administration program.

To remove all such UDAs from selected symbols on a drawing, see 8.6.34: Removing UDAs from Symbols.

• DataSet UDAs are groups of attributes that are set up for types of items or symbols that meet user-defined criteria. They are defined using the User Defined Attributes - DataSet Sub-Set of the AVEVA P&ID Project Administration program.

Once defined, user-defined attribute values can be entered using the AVEVA P&ID Properties Dialogs. They will be grouped under a node called User Defined Attributes.

Items on a drawing may be labelled with these values is required. See 8.6.33: Labelling Items with UDAs.

Note: If using the first method described above, a new attribute has been defined for a symbol of a type which already has labelled instances on a drawing, to add the new attribute to the labels of these symbols, enter UDAS at the command line, and select one of the symbols on the drawing. All the symbols of that type will then labelled with default value of the new attribute.

Attributes may be exported from AVEVA P&ID using the standard export procedures, and are exported in a separate output file that can be imported into AVEVA P&ID Reports. See 7.1: Exporting Data to an AVEVA P&ID Reports Database for details.

12.16:36© 2011 AVEVA Solutions Ltd

Page 367: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.13 Label Validation When P&ID graphics are labelled, online data validation may take place. There are five types of label validation:

• Label Validation against Lists of Valid Values • Label Format Validation• Label Uniqueness Validation• Label Validation across all Project P&IDs• Label Validation against Specifications

If possible, online validation should be left on, otherwise data is unchecked as it is entered, equating to a complete lack of automatic quality control. Manual checking would then have to be carried out.

6.13.1 Label Validation against Lists of Valid ValuesThis type of validation is switched on or off by the On-Line Data Validation checkbox on the Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program. The default setting is on.

When this type of validation is On, only valid entries may be selected when completing Properties Dialogs or entered at the command prompt, items with invalid labels are displayed in red in the Engineering Explorer, and drafting errors and omissions are highlighted with a balloon or symbol of the project's choice, and detailed in an error file. Where possible, these errors should be rectified before the data is exported to the database. Null characters may be used for pipe labels, if information is unknown.

The following label data is validated:

Area codes

Block codes

Equipment Type Letters (equipment descriptions for each equipment type).

Fluid/Service codes

Function codes

Identical Instruments are identified by suffixes

Instrument Types (i.e. PI=Pressure Indicator)

Insulation Codes

Line Number Uniqueness

Line/Pipe Sizes

Nozzle Sizes

Nozzle Tag Uniqueness (per equipment item)

Paint Codes

Reducer Inlet and Outlet of different sizes

Specification codes

Tracing Codes

Valve Closures (failure positions)

12.16:37© 2011 AVEVA Solutions Ltd

Page 368: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Valve Codes

Valve Sizes (if not placed in-line)

• Validation Files Entered data is checked against the allowable project values held in the project validation files.

The project validation files edited using the List of Values Configuration Category of the AVEVA P&ID Project Administration program. Alternatively, if the project is using VPE Workbench, the validation files can be supplied by that system and are then read-only. A directory path must be setup to VPE Workbench so that AVEVA P&ID can access these validation files.

Online validation does not prevent the data export, as this might unnecessarily hold up a project, when information is missing for only a small number of items.

• Typical Items When labels of typical items are validated on input, they are not only checked against the drawing labels but also typical labels on relevant items.

The validation process checks for duplicates. These are reported when the OK button on the typical data entry dialog box is pressed. The dialog box remains open so that the required changes can be made.

• Associated Project Configuration Options To activate online validation, check the On-Line Data Validation checkbox on the Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program.

If unlabelled nozzles are to result in an error message, check the Nozzle error balloon placement checkbox. If unlabelled reducers are to result in an error message, check the Reducer not labelled error balloon placement checkbox.

Enter the symbol used to indicate an error in the Symbol Name field. Enter the position in which error text is displayed in the Text position from origin field.

The validation files are located in the Validation Directory identified on the Project Configuration Category of the Administration program.

6.13.2 Label Format ValidationFor certain label fields, the project may be set to check that entered labels correspond to a specified format, in other words, that they consist of the correct type of characters in the correct order.

For example, the equipment Prefix field may be set so that all entries in this field must begin with an uppercase letter, followed by a lowercase letter, then a number, and so on.

These settings are made using the AVEVA P&ID Project Administration program, using the Pipes - Validation Sub-Set, Instruments - Validation Sub-Set, Equipment - Validation Sub-Set, Valves - Validation Sub-Set and Miscellaneous - Validation Sub-Set

If an invalid entry is made in a Properties dialog an error message is displayed, and the invalid label may not be placed.

12.16:38© 2011 AVEVA Solutions Ltd

Page 369: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.13.3 Label Uniqueness ValidationWithin most categories of item, for example, pipes or instruments, a label must be unique on a drawing. In addition, the project may be set to require that a selected field or a combination of fields in pipe, instrument and equipment labels also be unique.

The fields that are to be checked for uniqueness are selected on the Pipes - Labels Sub-Set, Instruments - Labels Sub-Set and Equipment - Labels Sub-Set of the AVEVA P&IDProject Administration program.

6.13.4 Label Validation across all Project P&IDs The project may be set to check that all labels in all P&IDs in a project are unique within a category of item, for example, pipes or instruments.

These settings are made using the AVEVA P&ID Project Administration program, using the buttons in the Label Validation Across P&IDs sections of the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Setand Miscellaneous - Settings Sub-Set.

If the Prevent option is selected, users are prevented from entering project duplicate labels for that category of item. If this is attempted, an error message is displayed and the duplicate labels may not be placed on the P&ID. The error message will identify the drawing number of the P&ID on which the other label (that the user attempted to duplicate) is located.

If the Warn option is selected, users are warned if they enter project duplicate labels for that category of item. The entry of duplicate labels is permitted in this case, but a warning message will be displayed on the P&ID, and will accompany the label data if it is transferred to VPE Workbench. The warning message will identify the drawing number of the P&ID on which the other label (that the user is duplicating) is located.

If the Ignore option is selected, no uniqueness validation of labels across P&IDs takes place. Duplicate labels may be entered in different P&IDs in this case. Duplicate labels are still not permitted in the same P&ID, except in the case of Valve and SPP labels.

If Prevent or Warn options are selected, the uniqueness of labels across a project is checked against an external database, either a VPE Workbench database, or if VPE Workbench is not available, an SQL database.

• Validation using a VPE Workbench DatabaseIf checking is against a VPE Workbench database, a connection to the VPE Workbenchdatabase should be established before labels are edited (see 8.8.7: Connecting to a VPE Workbench Database). This is because in order to check label uniqueness, AVEVA P&IDrefers to a snapshot of the VPE Workbench database, stored in an XML file, which is generated when the connection is made. After this has taken place, the connection may be discontinued if required, and label data will be checked against the database snapshot. However, entered label data cannot then be validated against label changes made in other drawings after the disconnection.

If Prevent or Warn options are selected, the system will also check for duplicate labels when a drawing is opened and when a connection to the VPE Workbench database is established. If any are detected, error or warning messages are placed on the drawing as appropriate.

12.16:39© 2011 AVEVA Solutions Ltd

Page 370: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

If Prevent or Warn options are set, but no connection to the database has been made when a drawing is opened, the system will check for duplicate labels against the data the in XML snapshot file instead of the database.

• Validation using an SQL DatabaseThe uniqueness of labels can alternatively be checked against an SQL database in a network location available to all project users of AVEVA P&ID. The database location is specified on the Project Configuration Category of the AVEVA P&ID Project Administration program.

Most label data is transferred to the database automatically when it is entered or changed if the Save to database on Update checkbox on the VPE Workbench Configuration Categoryof the AVEVA P&ID Project Administration program is checked. Some must be transferred using the Synchronise process. See 8.8.5: Synchronising Data with a VPE Workbench Database.

The table below specifies which label values will be transferred to the database automatically and which ones will be transferred when the Synchronise process is executed.

(√ = Transferred; X = Not transferred)

12.16:40© 2011 AVEVA Solutions Ltd

Page 371: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Values deleted in a drawing will only be deleted in the SQL database once the Synchronise process is executed.

• Validating Drawings Generated in other LocationsIf a project is being worked on in multiple locations, the P&IDs generated in these other locations must be sent to the office in which the validation database (either Workbench or SQL) is located. They must then be opened in AVEVA P&ID in order for the validation check to take place.

P&IDs can be e-mailed using the eTransmit facility (accessed from the File menu), which is available in AVEVA P&ID. Using this facility, multiple drawings can be sent in a .zip file, accompanied by a transmittal. A number of other options are also available.

See AutoCAD documentation for details.

• Points to Note • Duplicate labels that include null characters (e.g. "?") in the same positions are not

validated and may be entered regardless of the project settings. • If the Ignore option was set, but is subsequently changed to Prevent or Warn, when a

project drawing is reopened or refreshed, any duplicate labels for that category of item are displayed with an error message if the Prevent option was selected or a warning message if the Warn option was selected. Drawing data cannot be transferred to VPE Workbench if error messages are present.

• Each part of an SPP label is placed separately and may be deleted separately. If a part of an SPP label is deleted and as a result the label is now a duplicate of an SPP label on another project drawing, an error or warning message may be displayed if the Prevent or Warn option is selected on the Miscellaneous - Settings Sub-Set.

6.13.5 Label Validation against SpecificationsLabel validation against specifications is used to control which symbols can be inserted into pipes based on the specification of those pipes.

For example, it may be specified that Ball Valve symbols may only be inserted into pipes with a specification of AAA3, and an inlet bore size of 20 and an outlet bor size of 20. The project may be set either to prevent the insertion of symbols into pipes that are not of the correct specification, or to display such symbols in a specified colour.

Multiple combinations of pipe specs and sizes may be specified as compatible with the insertion of a symbol. If no specs or sizes are specified for a symbol, insertion of this symbol is unrestricted.

Spec/size insertion restrictions may be set up for Valves, Instrument Valves and Reducers.

Currently, only restrictions for 2-way symbols may be specified, but not symbols inserted at pipe junctions such as 3-way and 4-way valves.

Label validation against specifications is set up using the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program.

Note: Changes to drawings resulting from changes to Spec Driven settings are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded. See 8.2.4: Updating Spec Driven Data.

12.16:41© 2011 AVEVA Solutions Ltd

Page 372: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.14 AssembliesCollections of elements on drawing can be grouped together to create assemblies.

Three types of assembly may be created (see 8.9.1: Creating Assemblies):• Graphical Assemblies - pipes and symbols collected together into an AutoCAD block to

act as templates, retaining the item associations• Design Data Templates - collections of VPE Workbench or P&ID Data Grid designators

and values used to label items. See 6.16: Dynamic Labelling for further information.• Annotation Assemblies - there are two sub-types of Annotation Assemblies:

• Pipe: collections of pipe labels and symbols used to annotate pipes• UDA: collections of user-defined attribute labels and symbols used to annotate

pipes, instruments and equipment.

Once an assembly is created, it is added to the Assemblies symbol folder of the project. There is a sub-folder for each assembly type. In addition, the Annotation Assembly sub-folder contains sub-folders for each Annotation Assembly sub-type, and the UDA sub-type folder contains further sub-folders for each type of UDA assembly.

It may then be inserted in the similar way to other symbols. See 8.4.11: Inserting Assemblies.

Existing assemblies may only be removed by the AVEVA P&ID administrator.

6.15 Typical ItemsThe AVEVA P&ID Typical Items feature enables one item to be identified as having data that is typical of many items. The details of the items represented by the typical item are added to the label of the item on the P&ID, but do not appear on the P&ID. See 8.6.25: Labelling Typical Items.

The following items can be made typical of many:

Pipes

Off-Sheet Connectors (Pipe Flags)

Instruments

Equipment

SPP Items

Valve Items

Nozzles.

When data is transferred to VPE Workbench from the drawing, the data associated with each Typical Item is expanded into multiple sets where the items are created and revised in VPE Workbench as appropriate.

• User Interface For each item that can be made into a Typical Item, The Drawing Page shortcut menu includes a Typicals option. This option is available if the Typical Item facility is enabled at project level, and if the item has been labelled with the minimum mandatory data for the item type. The option accesses a dialog box for the entry, deletion and modification of the typical data.

12.16:42© 2011 AVEVA Solutions Ltd

Page 373: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Note: Currently, entry of typical data is available only by means of the dialog box. Command line entry of typical data will be available in the future.

For easy recognition of Typical items on the P&ID, each typical Item label should be displayed in a different colour to that of the equivalent non-typical label. These are selected using the project configuration options set using the AVEVA P&ID Project Administration program.

• Order of Typical Data The ordering of typical data is illustrated by the following example:

are connected to nozzle reference 'A' on:

This generates the following sets of destination information in the output file:

To facilitate the ordering of data, an order number is provided against each Typical data record. This number is automatically generated on input, but can be modified manually to enable re-ordering of the data sets. Deletion of a record in the Typical data set will automatically re-order the data.

6.15.1 Validation Validation of typical items is discussed in 3.5: Validation.

Typical pipe 1001

With Typical data: 1002

1003

1024

Typical Equipment V-1600-A

With Typical data: V-1600-B

V-1600-C

V-1600-D

Pipeline: 1001

Connected to: Nozzle A on V-1600-A

Pipeline: 1002

Connected to: Nozzle A on V-1600-B

Pipeline: 1003

Connected to: Nozzle A on V-1600-C

Pipeline: 1024

Connected to: Nozzle A on V-1600-D

12.16:43© 2011 AVEVA Solutions Ltd

Page 374: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.15.2 Sheet-to-Sheet Connections Where Typical pipes are connected across drawing sheet boundaries, the following rule applies; if a Typical pipe has a Typical flag label, it must connect to either a Typical pipe on the connecting sheet, or to a series of drawn pipes on the connecting sheet.

This rule ensures that when data is transferred to VPE Workbench and the typical cross-sheet connections are expanded, the transfer process can connect the pipes together correctly across sheets.

6.15.3 Unique identifiers in VPE Workbench Unique identifiers are maintained by the Typical items feature to ensure that VPE Workbench does not unnecessarily flag items for secondary loading. Unique identifiers are stored in the drawing alongside each Typical data record, so editing of the Typical data records will not destroy the unique identifiers.

6.15.4 Typical Item Flag in AVEVA P&ID Output Typical item flags appear in the Pipe, Pipe items and Instrument output files, to indicate items that are typical and not drawn on the P&ID.

6.15.5 Typical Items in VPE Workbench VPE Workbench includes a Typical item flag in all the item tables for Pipes, Pipe items and Instruments.

6.15.6 Associated Project Configuration Options The Typical Item feature can be turned on or off by the Typical Labelling checkbox on the Miscellaneous - Labels Sub-Set of the AVEVA P&ID Project Administration program.

The colours of typical items, as opposed to non-typical items, are also specified on this tab. There are fields for selecting colours for typical pipes, pipe flags, instruments, equipment, SPPs and valves.

6.16 Dynamic Labelling

6.16.1 Item Labels Items of equipment, instruments and lines may be labelled with dynamic labels. These consist of detail data selected from a VPE Workbench project database or from the P&ID Data Grid. See 8.8.9: Labelling with VPE Workbench Data and 8.6.22: Labelling with Data from the P&ID Data Grid.

These labels consist of a value, and optionally the designator associated with the value. The designator may be edited using the AVEVA P&ID labelling facilities (see 8.6: Labelling Symbols and Pipes). The value should not be edited, but should be kept up-to-date by refreshing them with the latest data from the VPE Workbench database (see 8.8.11: Refreshing VPE Workbench Data) or from the P&ID Data Grid (see 8.6.23: Refreshing P&ID Data Grid Labels).

The project can be set-up so that VPE Workbench values are refreshed automatically, whenever a connection to VPE Workbench is made (see 8.8.7: Connecting to a VPE Workbench Database).

12.16:44© 2011 AVEVA Solutions Ltd

Page 375: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

If no value exists for a designator, a placeholder for that value may be used instead. Once a value is defined for such a designator, the placeholder will be replaced by this value on refresh.

6.16.2 Design Data Templates A collection of values and designators can be grouped together to create an assembly. See 8.9.1: Creating Assemblies. The values and designators may be VPE Workbench values and designators or any of the values and designators that a drawing may be labelled with from the P&ID Data Grid, i.e. AVEVA P&ID, AVEVA P&ID Reports, AVEVA Instrumentation and AVEVA Schematic Database data.

Such assemblies are known as Design Data Templates, as opposed to the standard graphical assemblies consisting of pipes and symbols. Design Data Templates may be used on the same drawing or inserted into another drawing after creation.

When a new Design Data Template is created, it is automatically placed in the relevant Project Assemblies>Design Data Templates symbol folder (Instrument, Equipment, Pipe or Drawing). Design Data Templates may then be associated with any appropriate symbol, pipe, or with a drawing. The data they display is dynamic as described above, and will change to reflect the values for the item or drawing they are associated with. See 8.4.11: Inserting Assemblies.

Design Data Templates can only be removed by the AVEVA P&ID administrator.

Selecting a refresh of VPE Workbench data requires that a connection to VPE Workbenchbe established. See 8.8.7: Connecting to a VPE Workbench Database.

6.16.3 Tables Tables of VPE Workbench data may be placed on P&IDs, and subsequently refreshed with current data. See 8.8.10: Inserting Tables of VPE Workbench Data.

The appearance, position and content of these tables is specified on the VPE Workbench - Tables Sub-Set of the AVEVA P&ID Project Administration program.

Before tables of VPE Workbench data are placed or refreshed, a connection to VPE Workbench must be established. See 8.8.7: Connecting to a VPE Workbench Database.

6.17 General Editing, Notes and Revision Clouds General editing to drawings can be carried out by using the Cut, Copy, Paste, Delete and Rotate options on the shortcut menus. Items can also be stretched and mirrored using facilities in the Modify Group of the Home Tab.

See:

8.7.2: Moving Drawing Objects

8.7.1: Copying Drawing Objects and Labels

8.7.6: Deleting Drawing Objects

8.7.5: Rotating Drawing Objects

8.7.4: Stretching Drawing Objects

8.7.3: Mirroring Drawing Objects

12.16:45© 2011 AVEVA Solutions Ltd

Page 376: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

Inline items such as valves and reducers may be copied or moved from one pipe or process link to another by dropping the item onto the second pipe/process link, using the Cut/Copy, Paste options on the shortcut menu. This will correctly break the pipe/process link in the same way as a newly inserted item.

Whole branches and pipe networks can be copied together by selecting in the explorer and using the shortcut menu. Note that you cannot cut or copy pipes that are flagged as 'invalid'. They must be validated successfully first.

See 6.18: Deleting Items for more details of using the AVEVA P&ID delete facilities.

Facilities are provided to move of one or more items to the Non-Plotting Layer set in the project configuration file. See 8.7.9: Moving Items to the Non-Plot Layer.

Symbols may be exchanged individually or globally. For the individual symbol exchange option, you are prompted to select the new symbol from the Symbol List dialog box. The selected symbol must be of the same AVEVA P&ID type as the one being exchanged. The item type dictates the way AVEVA P&ID behaves when a symbol is inserted and these rules must be maintained at the symbol exchange. All labelling, including balloons, is retained. Undo twice to retrieve the original symbol if an error has been made, once to remove the new symbol, once to put back the old. If multiple symbols of the same type are selected in the drawing before the command is initialised they are all exchanged for the chosen symbol. See 8.7.7: Exchanging Individual Symbols.

If it is required change all symbols of one type to another, for example, to change all Ball Valves (BAVA) to Gate Valves (GAVA), global symbol exchange capabilities can be used. This can be achieved by entering BAVA under the Old Symbol heading and GAVA under the adjacent New Symbol heading in the Symbol Exchange List, which is accessed from the List of Values Configuration Category of the AVEVA P&ID Project Administration program, and by the use of the global symbol exchange facility used. This command can be used to swap symbols on demand provided that the two symbol item types are the same. It is not possible to swap one P&ID type for another, e.g.: Valves for Equipment. If the items do not match, an error will be received, listing the item types that do not match, and the old symbol is left in place. If problems are encountered, an AVEVA P&ID error balloon appears. See 8.7.8: Exchanging Symbols Globally.

Notes may be added to items on a drawing, and changes from a previous revision may be highlighted with revision clouds. See 8.6.29: Adding Notes to Items and 8.7.10: Drawing Revision Clouds.

6.18 Deleting Items To delete items from a drawing use the shortcut menus available from the Engineering Explorer or The Drawing Page. These can be accessed after selecting single or multiple items. See 8.7.6: Deleting Drawing Objects.

The consequences of deleting items in AVEVA P&ID vary because of the many different situations encountered. The results deleting using the AVEVA P&ID facilities are dictated by the item types involved and are summarised below.

In general, items associated together are deleted together.

Deleting an equipment item such as a vessel, with associated nozzles, pipe trim and electrical equipment from the explorer, will remove everything.

• When deleting an inline item from a pipe with tracing, select the tracing around the item as well as the item itself. Pipes are closed when inline items are deleted. Labels are removed automatically as appropriate or can be selectively removed.

12.16:46© 2011 AVEVA Solutions Ltd

Page 377: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

• When a labelled reducer is deleted, the line is closed and the user prompted for the size to retain. The size of the remaining pipe is revised accordingly, and cascades across pipe boundaries as necessary.

• Deleting an inline instrument also removes the label balloon, then closes the line and removes labels as normal.

• Non-AVEVA P&ID entities/elements are deleted as they would be in normal AutoCAD. • Deleting a Pipe which crosses over another pipe will only close the break in the line if

the break symbols are selected. • Deleting an instrument also removes any associated I/O rockets. • Nozzle labels are not automatically deleted when the label of the associated equipment

is deleted. • If a trim label is deleted, associated trim pipe labels are also deleted. • If the Number or Letter components of an equipment label are deleted, the rest of the

label will be deleted also. • Each part of an SPP label is placed separately and may be deleted separately. If a part

of an SPP label is deleted and as a result the label is now a duplicate of an SPP label on another project drawing, an error or warning message may be displayed if the Prevent or Warn option is selected on the Miscellaneous - Settings Sub-Set of AVEVA P&ID Administrator program.

• A title block of a drawing sheet may not be deleted if that drawing sheet has attribute values that are inherited by items on the drawing. This is to prevent the accidental deletion of large amounts of label data should the title block be inadvertently deleted. Before such a title block can be deleted, the project settings must be changed to remove the inheritance, and the previously inherited sheet attribute values set to null.

6.19 Detecting Corrupted Items During the creation of an intelligent AVEVA P&ID drawing, it is possible that items on a drawing will become corrupt. Facilities are available to detect and highlight such items.

Corrupted items are detected using the 8.8.1: Checking for Corrupted Items procedure. Items which are corrupted are then indicated with an error balloon.

12.16:47© 2011 AVEVA Solutions Ltd

Page 378: aveva p&id

AVEVA P&ID 12.1 User GuideDrawing P&IDs

6.20 Saving ChangesSave changes to the drawing in the normal way using the standard AutoCAD facilities.

When changes to a drawing are saved, the following dialog may be displayed, in which details of these changes and the current state of the drawing may be entered:

Whether or not the dialog is displayed in controlled by the setting of the Show Drawing History dialog box on the Drawing - Settings Sub-Set of the AVEVA P&ID Administration program.

12.16:48© 2011 AVEVA Solutions Ltd

Page 379: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

7 Data Transfer

7.1 Exporting Data to an AVEVA P&ID Reports DatabaseData is validated and exported for AVEVA P&ID Reports using the Exporting Data to a P&ID Reports Database procedure.

Data can be exported in three ways using this procedure:• In unconsolidated form to an intermediate database, from where it must subsequently

be consolidated using AVEVA P&ID Reports facilities.• In unconsolidated form to a number of output files, from where it must subsequently be

consolidated using AVEVA P&ID Reports facilities.• Consolidated drawing data transferred directly into the AVEVA P&ID Reports database.

Refer to the AVEVA P&ID Reports documentation for more information on AVEVA P&ID Reports facilities.

In order for data to be transferred directly into a P&ID Reports database, that database must first be logged into. See 8.8.3: Connecting to a P&ID Reports Database.

AVEVA P&ID Reports can be launched from AVEVA P&ID, and the database to which drawing data has been exported opened automatically. See 8.8.4: Opening a P&ID Reports Database. Note that the database must be logged into first (see above).

Project configuration settings for the interface with P&ID Reports, such as the database to which drawing data is exported, are specified on the P&ID Reports Configuration Categoryof the AVEVA P&ID Project Administration program.

7.1.1 Data ValidationData validation automatically takes place when a drawing is exported. It checks the following:

• that all nozzles are identified • that all reducers are identified • instrument process connections• that all spec breaks are identified • assembles all item data for inclusion in the output files.

Only objects within the limits of drawings, as specified on the Drawing - Grid Sub-Set of the AVEVA P&ID Project Administration program, will be validated.

12.17:1© 2011 AVEVA Solutions Ltd

Page 380: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

7.1.2 Points to Note

• Additional ProcessDuring an export, the following additional processes may take place:

• A copy of the drawing can be made available for AVEVA Model Management. In order for this to happen, the Save Copy checkbox on the Project Configuration Category of the AVEVA P&ID Project Administration program must be checked.

• Data can also be exported to VPE Workbench at the same time as it is exported to AVEVA P&ID Reports. See the Synchronising Data with a VPE Workbench Databaseprocedure for details.

• Generating Line ListsIf it is required to generate a simple line list from AVEVA P&ID using the export facility, line lists can be generated from "semi-intelligent" drawings, only partially upgraded from AutoCAD drawings (see 5: Upgrading AutoCAD Drawings), in which only the lines themselves are "intelligent" and any inline symbols are "dumb" AutoCAD blocks.

• Drawing Number Before data is exported from a flow diagram, a drawing number must have been assigned and added to the drawing. See 8.1.6: Adding a Title to a Drawing and entering Drawing Sheet Attributes. It is also recommended that a Title be added. Without the drawing number, validation and data export cannot proceed.

• Design Area If the 'Design area from title block used for Instrument Label Field 1' checkbox on the Drawing Labels pane is checked, and a design area is entered in the drawing Properties dialog, any instruments or equipment without a label prefix will have the design area exported as the prefix part of their label. For a vessel this may result in the label 20-V100, where 20 is the design area. Pre-existing instrument or equipment prefixes will not be overwritten. The area prefix is not visibly added to the label on the drawing; it is only added on export.

• Specification If the 'Populate Spec in Database' checkbox on the Pipes - Settings Sub-Set is checked, specification attributes of items are exported. If this checkbox is not checked, the values will be set to null in the engineering database.

7.2 Transferring Data to and from AVEVA Instrumentation and AVEVA Electrical

7.2.1 Exporting to AVEVA Instrumentation and AVEVA ElectricalWhen drawing data is synchronised (see 8.8.5: Synchronising Data with a VPE Workbench Database), copies of the synchronised drawings may be created in the Drawings Save Path field on the P&ID Reports Configuration Category of the AVEVA P&ID Project Administration program.

12.17:2© 2011 AVEVA Solutions Ltd

Page 381: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

Item data from these drawings can be imported into an AVEVA Instrumentation (AI) or AVEVA Electrical (AE) project, and the drawings themselves viewed in AI or AE. For details of these facilities, refer to AVEVA Instrumentation and AVEVA Electrical documentation.

7.2.2 Importing from AVEVA Instrumentation and AVEVA ElectricalInstruments from AVEVA Instrumentation and electrical equipment from AVEVA Electrical may be imported by placing them directly on to an AVEVA P&ID drawing.

This procedure is carried out using the P&ID Data Grid. From the P&ID Data Grid, an AVEVA Instrumentation or AVEVA Electrical project may be logged onto. The P&ID Data Grid then lists the instruments/electrical equipment in the project which have been added to a drawing in the AVEVA P&ID drawing in the P&ID project (Assigned Instruments and Assigned Electrical Equipment), and those that have not (Unassigned Instruments and Unassigned Electrical Equipment).

Instruments and electrical equipment are added to a drawing simply by dragging and dropping from the Unassigned Instruments and Unassigned Electrical Equipment nodes onto a drawing, and assigning a P&ID symbol type.

For details of this procedure, see 8.8.12: Transferring Data from AVEVA Instrumentation and AVEVA Electrical.

Imported instruments are added to the UNNAMED node in the Instrument Loops section of the Engineering Explorer.

The Derive Instrument AREA From field on the AI Integration Configuration Category of the AVEVA P&ID Project Administration program is used to specify the AVEVA P&ID Instrument tag field which will be populated with the Area values of instruments imported from AVEVA Instrumentation.

The Derive Equipment AREA From field on the AE Integration Configuration Category of the AVEVA P&ID Project Administration program is used to specify the AVEVA P&ID Equipment tag field which will be populated with the Area values of equipment imported from AVEVA Electrical.

7.3 Exporting to PDMS Schematic DatabasesData can be exported directly from the current P&ID drawing into an AVEVA PDMS Schematic Database.

The installation of PDMS that the AVEVA P&ID project is integrated with is selected on the PDMS Integration Configuration Category of the AVEVA P&ID Project Administration program.

Configuration is also required in PDMS to set up the interface between AVEVA P&ID and PDMS. See 9.9: Setting up PDMS to Connect with P&ID for details.

The database to which data is to be exported is selected a logged into using facilities provided by the P&ID Data Grid. The current content of the selected database can also be viewed in the P&ID Data Grid. See 4.5.6: Viewing and Exporting to a PDMS Schematic Database.

See 8.8.13: Transferring Data to PDMS Schematic Databases for the export procedure.

Note: Data can also be exported from single or multiple drawings to XML files in ISO 15928 format. This data can subsequently be imported into a PDMS Schematic database

12.17:3© 2011 AVEVA Solutions Ltd

Page 382: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

using the PDMS Schematic Model Manager module. See 7.7: Exporting to an ISO 15926 File.

Note: Data cannot currently be exported to AVEVA Marine Schematic Databases using this method.

7.4 Importing VPE Workbench Data Three types of data can be imported from a VPE Workbench project database into AVEVA P&ID. They are discussed below under the following headings:

• Importing Instrument Tag/Loop Numbers • Importing Equipment Design Data • Importing I/O Address Data.

In addition, drawings may be labelled with data from a VPE Workbench project database. See 6.16: Dynamic Labelling for details.

7.4.1 Importing Instrument Tag/Loop Numbers AVEVA P&ID imports instrument prefix, loop and suffix numbers from an external database. The information must be present in the correct format in the file <FILENAME>.ENI, where <FILENAME> is the filename of the flow diagram concerned. This file must be located in the data directory specified by the project configuration file.

The data is automatically imported on initialisation or loading of the software, provided that this facility is enabled in the project configuration file.

The limit and display position of loop information, such as prefix, loop, type etc., imported into the flow diagram is configurable by the project options for instrument balloon details. An exception report is created if items are not found on a flow diagram.

On initialising AVEVA P&ID, if the <FILENAME>.ENI file is found, the following message appears:

Writing Loop Numbers from External Database, Please Wait......

After data import, the program deletes the <FILENAME>.ENI file from the data directory to prevent reload of the information the next time that the drawing is accessed.

• Associated Project Configuration Options If instrument prefix, loop and suffix numbers are to be imported, the Loop Numbers from VPE Workbench checkbox on the Instruments - Labels Sub-Set of the AVEVA P&ID Project Administration program must be checked.

The directory from which the data is imported is specified using the VPE Data Path field on the Project Configuration Category.

• <DRAWING FILENAME>.ENI File Format The format of each record is:

Handle | Prefix | Type | Loop | Suffix

12.17:4© 2011 AVEVA Solutions Ltd

Page 383: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

For example: 2045 | 23 | PI | 1001 | NONE

Note: The use of the word "NONE" in the file replaces the absence of a field (in the example, a Suffix).

All fields may be a maximum of 32 characters in length.

The List Item Details procedure may be used to obtain the handle of an item if manually constructing the file.

7.4.2 Importing Equipment Design Data The EDL item type is used to associate a special symbol with a piece of equipment. The EDL symbol may be any chosen symbol and may be placed on the non-plot layer.

When an export of equipment data is carried out from VPE Workbench, an EDL file is created. The data is automatically imported when the P&ID is loaded and AVEVA P&ID is initialised, provided that this facility is enabled in the project configuration file.

When imported, the data appears attached to the correct EDL symbol on the P&ID. The first label piece of information is placed on the insert point of the symbol. The offsetting of successive items of equipment information when the data appears on the EDL symbol is controlled by settings in the project configuration file.

• Associated Project Configuration Options If the EDL data is to be imported, the Import Equipment Data checkbox on the Equipment - Settings Sub-Set of the AVEVA P&ID Project Administration program must be checked.

The placement of successive items of such equipment information is controlled by the Column X Offsets and Column Y offsets fields.

• <DRAWING FILENAME>.EDL File Format The format of each record is:

Handle | Prefix | Type | Loop | Suffix

For example: 2045 | 23 | PI | 1001 | NONE

Note: The use of the word "NONE" in the file replaces the absence of a field (in the example, a Suffix). All fields may be a maximum of 32 characters in length. The List Item Details procedure (see 8.9.5: List Item Details) may be used to obtain the handle of an item if manually constructing the file.

7.4.3 Importing I/O Address Data I/O Rockets are special symbols not supplied with the standard AVEVA P&ID set. I/O Rockets are used to assign single or multiple I/O (input/output) data against instruments or equipment. When I/O rockets are being used, the I/O data entered in VPE Workbench for those tagged items passes back onto the P&ID in a read-only form when AVEVA P&ID is initialised. The following message is received when this happens:

Writing I/O data from external database, Please wait......

12.17:5© 2011 AVEVA Solutions Ltd

Page 384: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

I/O rocket labels may be placed on the non-plotting layer via a setting in the project configuration file.

The labels for I/O Address, Card Type, Signal/Area Code and Remarks are automatically positioned in the same place for each rocket and the X, Y offsets in the project configuration options listed below control this automatic positioning with respect to the symbol insertion point.

Once the export has occurred, the files named after the P&ID name with an IIO extension must be placed in the \VPE Workbench directory of the AVEVA P&ID installation. This enables automatic detection of the file the next time the P&ID is loaded.

• Associated Project Configuration Options If I/O rocket labels are to be placed on the Non-plot layer, ensure that the Labels on Non-plot layer checkbox on the Instruments - Labels Sub-Set of the AVEVA P&ID Project Administration program is checked.

The X, Y offsets in the Offset from Symbol Origin fields control the automatic positioning of the I/O Address, Card Type, Signal/Area Code and Remarks components of the labels.

The four components of labels may be individually rotated as they are brought in from VPE Workbench. Check the appropriate Rotate with Symbol checkboxes to activate the rotation.

7.5 Exporting Data to a VPE Workbench DatabaseAVEVA P&ID can validate and export engineering item and connectivity data to the Plant Connectivity Model of a VPE Workbench database. This data can then be issued to the detailed engineering VPE Workbench modules and used as the basis for project documentation.

The following methods for exporting data to a VPE Workbench project database are available:

• The Synchronising Data with a VPE Workbench Database procedure, which is used to export data from a single AVEVA P&ID drawing. This procedure generates a number of output files. These may optionally be automatically copied to a specified publishing area, from where they are automatically imported into the intermediate data transfer tables of a specified VPE Workbench project. Optionally, the output files may be transferred (or re-transferred) to the publishing area using facilities on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program, as described below.

• Facilities are provided to export data from one or more previously synchronised drawings on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program. This facility transfers the output files generated from synchronised drawings into the publishing area as described above.

• The VPE Workbench Configuration Category also provides facilities to export data from one or more previously synchronised drawings to legacy VPE Workbench projects (i.e. pre-VPE Workbench 5.8). Data is transferred from the output files generated from synchronised drawings into the project database, into intermediate data transfer tables.

If exporting to a legacy project, a connection to the database in question must first be established by following the Connecting to a VPE Workbench Database procedure.

Details of the output files can be found in 9.2: Output File Format.

The folder into which these files are transferred to when a drawing is synchronised is set on the Project Configuration Category of the AVEVA P&ID Project Administration program.

12.17:6© 2011 AVEVA Solutions Ltd

Page 385: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

If exporting to a non-legacy project, the project and publishing area are defined on the VPE Workbench Configuration Category.

Note: See also 9.8: Setting up AVEVA P&ID to Connect with VPE Workbench.

7.5.1 Data ValidationData validation automatically takes place when a drawing is synchronised. It checks the following:

• that all nozzles are identified • that all reducers are identified • instrument process connections• that all spec breaks are identified • assembles all item data for inclusion in the output files.

Only objects within the limits of drawings, as specified on the Drawing - Grid Sub-Set of the AVEVA P&ID Project Administration program, will be validated.

7.5.2 Points to Note

• Additional ProcessDuring an export, the following additional processes may take place:

• A copy of the drawing can be made available for AVEVA Model Management. In order for this to happen, the Save Copy checkbox on the Project Configuration Category of the AVEVA P&ID Project Administration program must be checked.

• Data can also be exported to an SQL database if a VPE Workbench database is not available. If a suitable SQL database has been identified in the project configuration, most data is transferred automatically as a drawing is labelled. Other data must be transferred using the synchronisation process (see below). Data transferred to either type of database can be used to validate the uniqueness of label data within a category of item within a project. See 6.13.4: Label Validation across all Project P&IDs.

• Data can also be exported to AVEVA P&ID Reports at the same time as it is exported to VPE Workbench. See the Exporting Data to a P&ID Reports Database procedure for details.

• Generating Line ListsIf it is required to generate a simple line list from AVEVA P&ID using the Synchronise facility, line lists can be generated from "semi-intelligent" drawings, only partially upgraded from AutoCAD drawings (see 5: Upgrading AutoCAD Drawings), in which only the lines themselves are "intelligent" and any inline symbols are "dumb" AutoCAD blocks.

• Drawing Number Before data is exported from a flow diagram, a drawing number must have been assigned and added to the drawing. See 8.1.6: Adding a Title to a Drawing and entering Drawing Sheet Attributes. It is also recommended that a Title be added. Without the drawing number, validation and data export cannot proceed.

• Design Area If the 'Design area from title block used for Instrument Label Field 1' checkbox on the Drawing Labels pane is checked, and a design area is entered in the drawing Properties

12.17:7© 2011 AVEVA Solutions Ltd

Page 386: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

dialog, any instruments or equipment without a label prefix will have the design area exported as the prefix part of their label. For a vessel this may result in the label 20-V100, where 20 is the design area. Pre-existing instrument or equipment prefixes will not be overwritten. The area prefix is not visibly added to the label on the drawing; it is only added on export.

• Specification If the 'Populate Spec in Database' checkbox on the Pipes - Settings Sub-Set is checked, specification attributes of items are exported. If this checkbox is not checked, the values will be set to null in the engineering database.

• Exporting Items without Tag Numbers AVEVA P&ID permits the export of items without tag numbers by using temporary tag numbers. These numbers are automatically assigned by AVEVA P&ID at the time of export and are unique identifiers that can be seen on the screen. They are exported to the database and appear in square brackets, for example:

[21]

[34]

[45]

[56]

They can subsequently be edited in the database once the actual tag number is known. The updated tag numbers from the database then dynamically update the temporary tag numbers on the flow diagram when it is next loaded into AVEVA P&ID.

Each time an export is carried out for the same flow diagram, these temporary tag numbers will be the same. This feature enables VPE Workbench to trace the changes since the previous import.

7.6 Exporting Data to AVEVA NETData can be exported from AVEVA P&ID drawings into files that can subsequently be imported into AVEVA NET Portal:

• AVEVA EIWM (Engineering Information and Workflow Model) XML files containing the engineering data

• SVG files which are used to display the AVEVA P&ID drawings in AVEVA NET Portal.

The export is configured using the AVEVA NET - Configurations Sub-Set, AVEVA NET - Mappings Sub-Set and AVEVA NET - Setting Sub-Set of the AVEVA P&ID Project Administration program of the AVEVA P&ID Project Administration program.

Data can be exported from the current drawing in AVEVA P&ID. See 8.8.14: Publishing Data to AVEVA NET for details.

Facilities are also provided to export data from a batch of drawing in the AVEVA NET - Advanced Options Sub-Set of the AVEVA P&ID Project Administration program.

This pane also includes facilities to export data to a remote location such as a shared folder on a network.

12.17:8© 2011 AVEVA Solutions Ltd

Page 387: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

7.7 Exporting to an ISO 15926 FileDrawing data can be exported to XML files in ISO15926 format. These files contain both engineering item data and graphical data which can subsequently be imported into an AVEVA PDMS or AVEVA Marine Schematic databases using the Schematic Model Manager module.

Data can be exported to an ISO 15926 file either from a single drawing, or from a batch of drawings. See 8.8.15: Exporting Data to ISO 15926 Files.

Note: Data can also be exported directly from a single drawing into a PDMS Schematic database. See 7.3: Exporting to PDMS Schematic Databases.

If data is to be exported to PDMS, ensure that instrument and miscellaneous item label delimiters are set, to ensure tag format consistency with PDMS.

These delimiters are entered using the AVEVA P&ID Project Administration program, in the Instrument Dialog Labels section of the Instruments - Settings Sub-Set and the Dialog Box Field Labels section of the Miscellaneous - Labels Sub-Set.

If "Legacy" Process Links are to be used (PLK item type), i.e. Process Links without

the functionality introduced with AVEVA VPE P&ID 7.2 SP3, a number of factors should be considered when drawing process links if data is to be exported to an ISO 15926 file. For details, see Guidelines for Drawing Process Links.

If exporting data that is to be imported by the 12.0 SP5 version of PDMS or later, the 3.3.3 version of the ISO 15926 schema may be used. If exporting data to previous versions of PDMS (e.g. 12.0 SP4), the 3.2.0 version of the ISO15926 schema must be used.

Refer to 9.5: The ISO15926 (Version 3.2.0) Schema Specification or 9.6: The ISO15926 (Version 3.3.3) Schema Specification.

Note: All port sizes of 3-way and 4-way components are exported. The third size is exported as the "Secondary_size_1" value in the XML file, the fourth size as "Secondary_size_2". See the image below for an example.

12.17:9© 2011 AVEVA Solutions Ltd

Page 388: aveva p&id

AVEVA P&ID 12.1 User GuideData Transfer

7.8 Transferring Data to and from ExcelAll the item and drawing data of a drawing can be exported to Microsoft Excel spreadsheets. This data can then be edited in the spreadsheet using Excel facilities and imported back into AVEVA P&ID to update the drawing. Data can be exported from and to a single drawing or a batch of drawings.

See:• 8.8.16: Exporting Data to Excel• 8.8.17: Editing P&ID Data in an Excel Spreadsheet• 8.8.18: Importing Data from Excel

As part of the import procedure, changed data is validated. Invalid changes are highlighted on the spreadsheet so that they can easily be identified and corrected.

The format of the exported spreadsheet and the scope of data that is imported are specified on the Excel Interface Configuration Category of the AVEVA P&ID Project Administration program.

For details of the format of the spreadsheet see 9.7: Format of the Excel Interface Spreadsheet.

12.17:10© 2011 AVEVA Solutions Ltd

Page 389: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8 AVEVA P&ID Procedures

8.1 Preliminary Procedures

8.1.1 Specifying Project Settings

• DescriptionAVEVA P&ID can be configured to suit project requirements by means of project options. These are set using the AVEVA P&ID Project Administration program.

• InstructionsRefer to 2.3: AVEVA P&ID Project Administration Program.

8.1.2 Creating Drawings

• DescriptionNew AVEVA P&ID drawings can be created in a number of ways.

• InstructionsRefer to 6.2: Creating a New Drawing.

8.1.3 Upgrading AutoCAD Drawings to AVEVA P&ID Drawings

• DescriptionExisting "dumb" AutoCAD drawings can be upgraded to "intelligent" AVEVA P&ID drawings, using the AVEVA P&ID Drawing Upgrade Utility and procedures within AVEVA P&ID.

• InstructionsRefer to 5: Upgrading AutoCAD Drawings.

8.1.4 Upgrading Items from old Projects

• DescriptionA revised version of pipe lines that improved the performance and usability of the application considerably was introduced with AVEVA VPE P&ID 7.2 SP3.

12.18:1© 2011 AVEVA Solutions Ltd

Page 390: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

For projects developed using previous versions of AVEVA P&ID, an upgrade of the pipes and symbols on the project drawings is required before the drawings can be used in AVEVA VPE P&ID 7.2 SP3 or AVEVA P&ID 12.0 or later.

• InstructionsRefer to 2.1: Upgrading Pipes and Symbols from old Projects.

8.1.5 Opening a Drawing

• DescriptionAVEVA P&ID drawings can be opened in a number of ways.

• InstructionsRefer to 6.3: Starting and Exiting AVEVA P&ID.

8.1.6 Adding a Title to a Drawing and entering Drawing Sheet Attributes

• Description This procedure is used to add or edit the drawing numbers, sheet numbers, revision numbers, client drawing numbers and drawing titles of drawings. The command is also used to specify a design area to be used for export purposes by instruments/equipment that do not have an associated design area, to view the range of line and loop numbers used on a drawing and to enter other drawing sheet attribute that may be inherited by items on the drawing.

For details of the use of this procedure in the context of drawing P&IDs, see 6.4: Titling a Drawing.

Note: If the drawing number is associated with a VPE Workbench project, details of that project may be viewed. See 8.8.9: Labelling with VPE Workbench Data.

12.18:2© 2011 AVEVA Solutions Ltd

Page 391: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• ErrorsAn error message will be received during validation if a drawing number is not associated with a drawing.

• Associated Project Configuration Options • If the design area is to appear in the title, ensure that the Design area from Title Block

used for Instrument Label field 1 checkbox on the Drawing - Labels Sub-Set of the AVEVA P&ID Project Administration program is checked.

• If the project number is to be part of the drawing title, check the Place Project Number Label as part of Drawing Title checkbox.

• The numbers of drawing areas, drawing numbers and project number labels to include in the title are specified in the 3 fields in this pane.

• Sheet attribute field names and coordinates of their labels on drawing are set up using the Drawing - Settings Sub-Set.

• Entries into sheet attribute fields may be restricted by setting up validation rules using the Drawing Information – Validation Sub-Set.

12.18:3© 2011 AVEVA Solutions Ltd

Page 392: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Establish inheritance between item label and sheet attribute fields using the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Line Fittings Configuration Category.

• Instructions 1. Start the procedure by selecting the Properties option from the shortcut menu of The

Drawing Page. 2. The AVEVA P&ID Drawing properties dialog is then displayed (see 4.8: Properties

Dialogs):

Enter or edit the details as required.

12.18:4© 2011 AVEVA Solutions Ltd

Page 393: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. To enter, edit or view Sheet Attribute and Line and Loop Number Range Data in the fields provided:

Enter or edit data as required. Depending on project set up, the values entered in the Drawing Sheet Attribute fields may be inherited by items on the drawing. Click on OK to return to the AVEVA P&ID Drawing Properties dialog.

4. Once title details have been entered you will be prompted to position the data on the drawing. For example:

Position Drawing Number:

You will only be prompted to position data from fields that you have actually completed.

While positioning title data you may be required to specify the rotation and height of the text.

12.18:5© 2011 AVEVA Solutions Ltd

Page 394: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.2 Implementing Configuration Changes

8.2.1 Overview

• DescriptionMost project configuration changes are automatically implemented in a drawing when it is opened. However there are exceptions to this, and project configuration changes may also be implemented manually once a drawing has been opened, as described below.

• Associated Project Configuration Options All project configuration changes are made using the AVEVA P&ID Project Administration Program.

• Instructions• Configuration Changes that must be implemented by the user• Configuration Changes that may optionally be implemented• Implementing Configuration Changes made since a drawing was opened

- Configuration Changes that must be implemented by the user

Some configuration changes are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded using the following procedures:

• Updating Equipment Tags• Updating PipeTags• Updating Spec Driven Data• Convert Project Label Units

- Configuration Changes that may optionally be implemented

If project configuration changes have been made to text styles or to the appearance settings of labels, or if they have been changed in the drawing and are now different from the project settings, the following message is displayed when a drawing is opened:

Click Yes to set the appearance of labels to those defined in the project settings.

Click No the keep the current appearance of the labels on the drawing.

12.18:6© 2011 AVEVA Solutions Ltd

Page 395: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Implementing Configuration Changes made since a drawing was opened

To implement configuration changes made since the drawing was opened, select the Refresh Settings option in the AVEVA P&ID Group of the Home Tab. The following message is then displayed:

Click Yes to continue. Configuration changes are then implemented with the exceptions described above.

8.2.2 Updating Equipment Tags

• Description Changes to drawings resulting from the Equipment Label Format project configuration settings being changed are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded using this procedure.

Note: As an alternative to the procedure below, if only a single label is to be updated, opening and closing the Properties dialog (see 4.8: Properties Dialogs) of that equipment will update its label format.

• Associated Project Configuration Options This procedure is used to implement changes made to the Equipment Label Format settings on the Equipment - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• Instructions1. Start the procedure by selecting the Update Equipment Tag option in the Project

Configuration Group of the Utilities Tab..2. The command prompt will display:

Pick Equipments for reformatting the tags:

Select the equipment the tags of which are to be updated. When all the required equipment has been selected, press Enter.

If all equipment tags on the drawing are to be updated, enter "all" at the command prompt and press Enter. It is recommended that a Zoom Extents is performed before proceeding with this option.

12.18:7© 2011 AVEVA Solutions Ltd

Page 396: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The command prompt will display the number of selected equipment items (for example):

5 found

The labels of the selected equipment are then updated. If many equipment items have been selected, this may take a few moments.

8.2.3 Updating PipeTags

• Description Changes to drawings resulting from the Display Label Format project configuration setting beings changed are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded using this procedure.

Note: Split pipe labels cannot be updated using this procedure.

Note: As an alternative to the procedure below, if only a single label is to be updated, opening and closing the Properties dialog (see 4.8: Properties Dialogs) of that pipe will update its label format.

• Associated Project Configuration Options This procedure is used to implement changes made to the Display Label Format settings on the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by selecting the Update Pipe Tag option in the Project

Configuration Group of the Utilities Tab..2. The command prompt will display:

Pick pipe group for reformatting the tags:

Select the pipes the tags of which are to be updated. When all the required pipes havw been selected, press Enter.

If all pipe tags on the drawing are to be updated, enter "all" at the command prompt and press Enter. It is recommended that a Zoom Extents is performed before proceeding with this option.

3. The command prompt will display the number of selected pipes (for example):

5 found

The labels of the selected pipes are then updated. If many pipes have been selected, this may take a few moments.

12.18:8© 2011 AVEVA Solutions Ltd

Page 397: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.2.4 Updating Spec Driven Data

• Description Changes to drawings resulting from changes to Spec Driven Project Configuration settings are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded using this procedure.

• Example:Out of spec items highlighted in magenta:

• Associated Project Configuration Options This procedure is used to implement changes made to the settings on the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by selecting the Update Spec Driven Data option in the Project

Configuration Group of the Utilities Tab.. It is recommended that a Zoom Extents is performed before proceeding.

2. The command prompt will display:

Regenerating model.

Symbols on the drawing are then checked against the new settings and the drawing is regenerated so that the symbols that are now "out of spec" are displayed in the colour selected for such items in the project settings.

3. The command prompt will display then number of symbols that are out of spec, the number of symbols which are in spec, and the colour in which out of spec symbols are displayed, for example:

7 symbols are out of spec; 68 symbols are Ok; Symbols highlighted in 6 color are out of spec

12.18:9© 2011 AVEVA Solutions Ltd

Page 398: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The command ends automatically.

8.2.5 Convert Project Label Units

• Description Changes to drawings resulting from the label units project configuration setting being changed are not automatically implemented when project drawings are loaded. The user must trigger these changes "manually" in each drawing after it has loaded using this procedure.

• Associated Project Configuration Options This procedure is used to implement changes resulting from the Label Units setting on the Project Configuration Category of the AVEVA P&ID Project Administration program being changed.

• Instructions 1. Start the procedure by selecting the Convert Units option in the Project Configuration

Group of the Utilities Tab.2. The command prompt will display:

Select objects or <select all>:

Select the labels which are to be updated. When all the required labels have been selected, press Enter.

If all labels on the drawing are to be updated, enter "all" at the command prompt and press Enter. It is recommended that a Zoom Extents is performed before proceeding with this option.

3. The command prompt will display the number of selected labels (for example):

5 found

The selected labels are then updated. If many labels have been selected, this may take a few moments.

12.18:10© 2011 AVEVA Solutions Ltd

Page 399: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.3 Changing AVEVA P&ID Settings

8.3.1 Turning Automatic Flow Arrows On and Off

• Description This procedure is used to switch automatic flow arrows, placed on pipes as they are drawn, on or off. This setting only affects new pipes and not existing ones, even on reloading the drawing.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.4: Indicating Pipe Flow.

• Associated Project Configuration Options • If flow arrows are to be automatically placed at direction change points, ensure that the

Automatic Arrows checkbox on the Pipes - Settings Sub-Set of the AVEVA P&IDProject Administration program is checked.

• Specify the symbol to be used to represent a flow arrow in the Symbol Name field.

• Instructions 1. Start the procedure by checking or unchecking the ARROWS checkbox in the Pipeline

Group of the Home Tab. 2. Flow arrows will immediately be switched on or off.

8.3.2 Turning Automatic Tracing On and Off

• Description This procedure is used to turn automatic tracing, placed on pipes when they are drawn, to be turned on or off. This setting only affects new pipes and not existing ones, even on reloading the drawing.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.3: Tracing Lines.

• Example

• Instructions 1. Start the procedure by checking or unchecking the TRACE checkbox in the Pipeline

Group of the Home Tab.

12.18:11© 2011 AVEVA Solutions Ltd

Page 400: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. Automatic tracing will immediately be switched on or off.

8.3.3 Turning Automatic Breaks On and Off

• Description This procedure is used to switch on or off the facility which causes a pipe or link to automatically break another pipe or link where they cross.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.1: Drawing Pipes and Process Links

• Example

• Associated Project Configuration Options • If pipes are to be broken automatically when crossed, the Automatic Breaks ON

checkbox, on the Pipes - Settings Sub-Set of the AVEVA P&ID Project Administration program must be checked.

• The break priority, i.e. whether the horizontal or vertical pipe is broken where a break occurs, is set using the Break Pipe Direction buttons.

• The width of the gap in a broken pipe is set in the Break Distance field. • The symbol chosen to represent the break is selected in the Symbol Name field. • The layer into which break symbols are placed is specified in the Symbol Layer field. • The colour of the break symbol is set in the Symbol Colour field.

• Instructions 1. Start the procedure by checking or unchecking the BREAK checkbox in the Pipeline

Group of the Home Tab. 2. Automatic breaks will immediately be switched on or off.

8.3.4 Turning the Display of Ports On and Off

• Description This procedure is used to switch the display of the ports on symbols on and off.

For details of the use of this procedure in the context of drawing P&IDs, see 6.5: Inserting Symbols.

12.18:12© 2011 AVEVA Solutions Ltd

Page 401: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Instructions 1. Complete the procedure by right-clicking on The Drawing Page and selecting either

Ports Display - on or Ports Display - off. 2. The display of ports will then immediately be switched on or off.

8.3.5 Selecting the Style of New Pipes

• Description This procedure is used to select the style of new pipes/links. This procedure only affects pipes and process links drawn subsequent to this procedure being carried out.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.1: Drawing Pipes and Process Links.

• Example

• Errors The following message indicates that the relevant AutoCAD linetypes have not been loaded onto the drawing:

"Unable to make pipe header".

• Instructions Complete the procedure by selecting the required style from the dropdown list in the Pipeline Group of the Home Tab.

Once the style has been set any subsequently drawn pipes will be drawn with the new style.

8.3.6 Selecting the Tracing Style of New Pipes

• Description This procedure sets the style of tracing to be applied to subsequently drawn pipes. Any new tracing is drawn with the set style.

12.18:13© 2011 AVEVA Solutions Ltd

Page 402: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.3: Tracing Lines.

• Associated Project Configuration Options The distance between tracing and a line, and the default tracing style used are set in the Offset and Default fields on the Tracing Styles pane in the AVEVA P&ID Project Administration program.

• Instructions Complete the procedure by selecting the required style from the dropdown list in the Pipeline Group of the Home Tab.

Once the style has been set any subsequently tracing will be in the new style.

8.3.7 Selecting the Style of New Signal Lines

• Description This procedure is used to select the style of new signal lines. This procedure only affects signal lines drawn subsequent to this procedure being carried out.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.2: Drawing Signal Lines.

• Instructions Complete the procedure by selecting the required style from the dropdown list in the Signal Line Group of the Home Tab.

Once the style has been set any subsequently drawn signal lines will be drawn with the new style.

12.18:14© 2011 AVEVA Solutions Ltd

Page 403: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.4 Inserting Symbols

8.4.1 Inserting Symbols - General Information

• Description This procedure is used to insert any available AVEVA P&ID or client symbol from the symbol library into a drawing.

For details of the use of this procedure in the context of drawing P&IDs, see 6.5: Inserting Symbols.

• General Points When an item is inserted into a drawing it will be placed on the default layer, in the default colour for the item type (see Associated Project Configuration Options below), and in the default line type. If no default layer or colour is specified for the item type, it will be placed in the current layer and will adopt the current layer colour.

Placing a symbol in a pipeline or signal line automatically breaks the line and orientates the symbol accordingly.

Equipment items, including vessels and electrical equipment, can be set to be re-sizable for a project.

• Inserting 1-point & 2-point symbols All symbols may be classified as 1-point or 2-point. 1-point symbols e.g. pumps, have a single insertion point and are placed with a single click of the mouse or puck.

2-point symbols e.g. reducers, spec breaks etc. have an insertion point, and a second point which must be selected to determine the orientation or direction of the symbol. Hence two mouse clicks are needed to correctly place a reducer.

Assume the insertion point to be at the wide end of the reducer, as seen in the example below:

Whether a symbol is a 1-point or a 2-point symbol is determined by the setting in Column 7 on the Symbols Configuration Category of the AVEVA P&ID Project Administration program.

• Inline Equipment Inline equipment can be inserted into a pipe and labelled as equipment. Routing through inline equipment is as for any inline item.

12.18:15© 2011 AVEVA Solutions Ltd

Page 404: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration Options • The locations of directories used to store standard and project symbol files, both metric

and imperial, and whether the program will search for a symbol in the project or standard directory first, are set on the Project Configuration Category of the AVEVA P&ID Project Administration program.

• Whether or not the Symbol Explorer is displayed is also controlled by a setting on the Project Configuration Category.

• The list of available symbols and their properties can be viewed and edited using the Symbols Configuration Category.

• The default drawing layers and colours for item types are set up on the Item Types - Standard Sub-Set.

• Layers are configured on the Drawing - Layers Sub-Set. • The specs and sizes of pipes that Valve and Reducer symbols may be restricted to are

specified using the Spec Driven Configuration Category.

• Insertion Methods These instructions provide a basic description the different methods of inserting symbols. They are applicable for all symbol types.

• The Symbol Explorer Symbols can be selected and inserted using the Symbol Explorer. The selected symbols can be inserted either by dragging them onto The Drawing Page, or by selecting Insert from the item shortcut menus. A 'ghosted' image of the selected symbol will then appear on the cross hairs ready for 'dropping' at the required point on the drawing. Refer to the topics regarding the insertion of different symbol types for further details.

Using the Symbol Explorer, symbols can also be inserted as AutoCAD blocks instead of as "intelligent" AVEVA P&ID symbols.

• The AVEVA P&ID Tool Palette Symbols can be inserted by dragging and dropping from the AVEVA P&ID Tool Palette. This functions in the same way as the AutoCAD Tool Palette. Refer to the topics regarding the insertion of different symbol types for further details.

• Copying and Pasting Instead of inserting symbols using the methods described above, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

• Detailed Procedures for Symbol Types For detailed information on selecting different types of symbols, see the appropriate topic:

• 8.4.2: Inserting Equipment• 8.4.3: Inserting Electrical Equipment • 8.4.4: Inserting Nozzles • 8.4.5: Inserting Valves • 8.4.6: Inserting Instrument Valves (Control Valves)• 8.4.7: Inserting Inline Fittings

12.18:16© 2011 AVEVA Solutions Ltd

Page 405: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• 8.4.8: Inserting Instruments (Balloons) • 8.4.9: Inserting Flow Elements • 8.4.10: Inserting Miscellaneous Symbols • 8.4.11: Inserting Assemblies

Note: Vacuum/Relief Devices are a sub-category of Instrument Valves.

8.4.2 Inserting Equipment

• Description General points on the procedure are given in8.4.1: Inserting Symbols - General Information.

Equipment items are positioned stand-alone. All equipment items can be configured so that they can be re-sized, using the Symbols Configuration Category of the AVEVA P&ID Project Administration program.

Vessels have the EQV item type and all other equipment is classified as EQU.

Note: Electrical Equipment is discussed in 8.4.3: Inserting Electrical Equipment. Equipment Data Location is discussed in 8.4.10: Inserting Miscellaneous Symbols.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

• Example

12.18:17© 2011 AVEVA Solutions Ltd

Page 406: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration OptionsEquipment may be set either to be fixed size or re-sizable upon insertion. This setting is made on the Symbols Configuration Category of the AVEVA P&ID Project Administration program. If an item is set to be re-sizable, a prompt will be received upon insertion for size in both the X and Y directions after the item is inserted.

• Instructions 1. Select an equipment symbol by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the equipment will appear on the cross hairs. The Command prompt will display:

Indicate point for <chosen equipment>:

Pick the desired position. 3. If the item type is set to be re-sizable, the Command prompt will then display:

X scale factor <1>:

Enter an X scale factor via the keyboard if required. 4. The Command prompt will then display:

Y scale factor <default X>:

The Y scale defaults to the X scale automatically unless another value is entered. 5. The Command prompt will then display:

Rotation angle <0.000>:

Enter a rotation angle if required.

Note: You can 'show' the rotation angle by picking two points. The item is then placed.

6. The Command prompt will then display:

Indicate point for <chosen equipment>:

Place another item, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

If auto-labelling is on, the Labelling Equipment (with or without Trim) procedure will then start automatically.

12.18:18© 2011 AVEVA Solutions Ltd

Page 407: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.4.3 Inserting Electrical Equipment

• Description General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

Electrical equipment must be associated to another equipment item during insertion.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels details.

• Example

• Errors If an attempt is made to insert electrical equipment without forming an association with an equipment item, an error message will be received.

• Associated Project Configuration OptionsElectrical equipment may be set either to be fixed size or re-sizable upon insertion. This setting is made on the Symbols Configuration Category of the AVEVA P&ID Project Administration program. If an item is set to be re-sizable, a prompt will be received upon insertion for size in both the X and Y directions after the item is inserted.

• Instructions 1. Select an electrical equipment symbol by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

12.18:19© 2011 AVEVA Solutions Ltd

Page 408: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. When symbol has been selected the 'ghosted' image of the symbol appears on the cross hairs. The Command prompt will then display:

Indicate point for <chosen item>:

Pick a point for the electrical equipment item. 3. The Command prompt will then display:

Indicate equipment item for association:

Select the equipment item with which the electrical equipment item is to be associated with.

4. If the Electrical Equipment symbol type is set to be re-sizable, the Command prompt will then display:

X scale factor <1>:

Enter an X scale factor via the keyboard if required. 5. The Command prompt will then display:

Y scale factor <default X>:

The Y scale defaults to the X scale automatically unless another value is entered. 6. The Command prompt will then display:

Rotation angle <0.000>:

Enter a rotation angle if required.

Note: You can 'show' the rotation angle by picking two points. The item is then placed.

7. The Command prompt will then display:

Indicate point for <chosen item>:

Pick a point for placement of another item, or select Cancel from The Drawing Pagemenu or press Ctrl-C to end the command.

If auto-labelling is on, the Labelling Electrical Equipment procedure will then start automatically.

12.18:20© 2011 AVEVA Solutions Ltd

Page 409: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.4.4 Inserting Nozzles

• Description General points on the insertion procedure are given under 8.4.1: Inserting Symbols - General Information.

Nozzles are two point symbols and must be owned by an equipment item in order to be inserted successfully. For example, they can be inserted onto pumps and vessels.

Nozzles can be moved around on the same vessel, but not between vessels. Nozzles can be copied between vessels and re-association takes place automatically to the correct vessel. An entire vessel and its attached nozzles can be copied and the correct association will be maintained. The Show Associations between Items procedure should be used to establish which items are associated.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

• Example

• Errors An error message occurs when trying to attach a nozzle to something other than an equipment item or when a nozzle has not attached itself physically to anything. Associate the nozzle physically to an equipment item or pick an item for association when prompted. Otherwise the nozzle will disappear.

12.18:21© 2011 AVEVA Solutions Ltd

Page 410: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Select a nozzle symbol by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the nozzle will appear on the cross hairs. The Command prompt will then display:

Indicate point for <chosen Nozzle >:

Pick a point on an equipment item. 3. The Command prompt will then display:

Indicate point to show angle of <chosen Nozzle >:

Pick a point to show the direction in which the nozzle is to face. 4. The Command prompt will then display:

Indicate point for <chosen Nozzle >:

Place another nozzle, or press Ctrl-C to end the command. 5. If the nozzle is not placed on an equipment item, the Command prompt will display:

Indicate Equipment item for association:

Pick the equipment item. If no item is selected the nozzle will not be inserted and will disappear.

If auto-labelling is on, the Labelling Nozzles procedure will then start automatically.

8.4.5 Inserting Valves

• Description General valves must be inserted into pipes, links or signal lines, otherwise an error message will be received. This message occurs when the symbol has been defined to break into pipes in the Symbols Configuration Category of the AVEVA P&ID Project Administration program, or the pipe, link or signal line was missed when trying to insert an item e.g. line fitting or valve. Check and change the settings in the project configuration, or try to be more accurate when inserting items.

General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

12.18:22© 2011 AVEVA Solutions Ltd

Page 411: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

• Examples

• Associated Project Configuration Options Valve symbols may be restricted so that they can only be inserted into pipes with specific codes and sizes. These are specified using the Spec Driven Configuration Category.

• Instructions 1. Select a valve symbol by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the valve will appear on the cross hairs. The Command prompt will display:

Insertion point:

Pick a point on a pipe, a process link, or a nozzle.

The valve will be inserted, will orientate itself with the pipe and will adopt the correct colour and layer according to project configuration. 3-way valves will automatically orientate themselves correctly when placed on 3-way pipe intersections.

3. The Command prompt will then display:

Insertion point:

Pick a point for another valve, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

If auto-labelling is on, the Labelling General Valves procedure will then start automatically.

Note: A Valve symbol can be converted into an Instrument Valve symbol by adding an Actuator symbol to it. See 8.4.6: Inserting Instrument Valves (Control Valves).

12.18:23© 2011 AVEVA Solutions Ltd

Page 412: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.4.6 Inserting Instrument Valves (Control Valves)

• Description General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

Instrument valves behave as for general valves except that they have a mandatory label balloon and an optional link line attached. If necessary, the label balloon can be independently positioned and moved after the instrument valve has been placed, and the point at which it connects to the valve changed.

Instrument valves can be inserted in two ways:• By inserting a symbol from the Instrument Valves symbol category consisting of a valve

body and an actuator.• By inserting a symbol from the Valves symbol category, consisting of a valve body, then

adding an actuator symbol or symbols to it to make it an Instrument Valve.

Handwheels also fall within the Instrument Valve symbol category, and may be inserted onto instrument valves. Only one handwheel may be placed on an Instrument Valve.

Where an instrument valve is placed between the end node of one pipe, and the start node of another, this valve may serve as the source and destination of the labels of these pipes, as opposed to the pipe nodes, depending on the type of valve that it is.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

12.18:24© 2011 AVEVA Solutions Ltd

Page 413: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example Some examples of instrument valves are shown below:

• Errors An error message will be received if an attempt is made to put two handwheels on the same control valve.

• Associated Project Configuration Options • The block name of the instrument label balloon symbol is specified in the Label Balloon

Symbol field on the Instruments - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• The presence or absence of link lines is controlled by the Label Balloon Link-Lines Off checkbox on the same pane.

• Instrument valve symbols may be restricted so that they can only be inserted into pipes with specific codes and sizes. These are specified using the Spec Driven Configuration Category.

• Instructions• Inserting a Complete Instrument Valves Symbol• Inserting a Valve Symbol then adding Actuator Symbols• Adding a Handwheel

- Inserting a Complete Instrument Valves Symbol

1. To insert a symbol that consists of both a valve body and an actuator, select the Instrument Valves symbol category by: • using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

12.18:25© 2011 AVEVA Solutions Ltd

Page 414: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. After the symbol has been selected a 'ghosted' image of the instrument valve will appear on the cross hairs. The Command prompt will display:

Insertion point:

Pick a point on a pipe.

The valve will be inserted, will orientate itself with the pipe and will adopt the correct colour and layer according to project configuration. 3-way valves will automatically orientate themselves correctly when placed on a 3-way pipe intersection.

3. The Command prompt will then display:

Show side of Actuator:

Pick a point to indicate which side of the valve the actuator is on. 4. A 'ghosted' image of the instrument balloon will appear on the cross hairs, the

Command prompt will then display:

Insertion point:

Place 'ghosted' balloon. 5. If link lines between instruments and balloons are on (i.e. the Label Balloon Link-Lines

Off checkbox is checked in the AVEVA P&ID Project Administration program), the command prompt will then display:

Indicate point on symbol:

Press Enter to attach the link line to the insert point of the instrument valve, or place the connection point "manually" by clicking on the required point.

6. The Command prompt will then display:

Insertion point:

Pick another point, or press Ctrl-C to end the command.

- Inserting a Valve Symbol then adding Actuator Symbols

1. Select a valve symbol by: • using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

12.18:26© 2011 AVEVA Solutions Ltd

Page 415: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. After the symbol has been selected a 'ghosted' image of the valve will appear on the cross hairs. The Command prompt will display:

Insertion point:

Pick a point on a pipe.

The valve will be inserted, will orientate itself with the pipe and will adopt the correct colour and layer according to project configuration. 3-way valves will automatically orientate themselves correctly when placed on 3-way pipe intersections.

3. The Command prompt will then display:

Insertion point:

Pick a point for another valve, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

If auto-labelling is on, the Labelling General Valves procedure will then start automatically.

4. Select an actuator symbol by: • using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

In the Symbol Explorer, actuator symbols are located in a sub-folder of the Valves folder.

5. After the symbol has been selected a 'ghosted' image of the actuator will appear on the cross hairs. The Command prompt will display:

Insertion point:

Pick a valve. Note that you can add multiple actuator symbols to the same valve body symbol.

6. If the valve has been inserted into a vertical line, the Command prompt will then display:

Get angle:

Pick a point to indicate which side of the valve the actuator is on.

The actuator will be inserted on the selected valve, will orientate itself with the valve and will adopt the correct colour and layer according to project configuration.

12.18:27© 2011 AVEVA Solutions Ltd

Page 416: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

7. A 'ghosted' image of the instrument balloon will appear on the cross hairs, the Command prompt will then display:

Insertion point:

Place 'ghosted' balloon. 8. If link lines between instruments and balloons are on (i.e. the Label Balloon Link-Lines

Off checkbox is checked in the AVEVA P&ID Project Administration program), the command prompt will then display:

Pick a point on symbol:

Press Enter to attach the link line to the insert point of the instrument valve, or place the connection point "manually" by clicking on the required point.

9. The Command prompt will then display:

Insertion point:

Pick a valve for another actuator, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

- Adding a Handwheel

1. Add a handwheel to an Instrument Valve by: • using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. When a handwheel has been selected, the command prompt will display:

Insertion point:

Pick the instrument valve. 3. The Command prompt will then display:

Get angle:

Pick a point to indicate which side of the valve the handwheel is on. 4. The Command prompt will then display:

Insertion point:

12.18:28© 2011 AVEVA Solutions Ltd

Page 417: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Attach a handwheel to another valve, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

If auto-labelling is on, the Labelling General Instruments procedure will then start automatically.

8.4.7 Inserting Inline Fittings

• Description General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

This procedure covers the insertion into the drawing of symbols for line fittings, and for inline paint, tracing, insulation or spec breaks.

Line fittings must be placed in a line or at the end of a line, depending on the type of item. For example, off-sheet connectors (pipe flags), end caps and spec breaks go on the end of a line, whereas a flame trap or a reducer must be inserted into the line itself.

Descriptions of the fittings which form Pipe Destinations are included in the output file as pipe destinations. Spec breaks must be associated with another entity at the pipe connection point.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

Note: When placing breaks at the ends of pipes (as opposed to inline breaks), the SPECBRK2_END and SPECBRK_END_LINE symbols must be used.

• Example

• Errors An error message occurs when the symbol has been defined as on that break into pipes, but is not placed to do so.

12.18:29© 2011 AVEVA Solutions Ltd

Page 418: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

An error message also occurs when attempting to place an item inline that should be placed only at the ends of pipes e.g. end cap or spec break, start and end nodes etc. In either case, check the Symbols Configuration Category of the AVEVA P&ID Project Administration program - insertion into pipes and links should be set to No. The item type for that item may need to be changed to Pipe Destination Fitting (PDF).

• Off-Sheet Connectors Off-sheet connectors (pipe flags) may be inserted automatically when a pipe is drawn, as defined by the pipe end styles setting in the Pipeline Group of the Home Tab.

It is recommended that off-sheet connectors with symbol names ending in -IN or -OUT be used. These can be placed on pipes drawn at any angle and drawn in any direction, and will orientate themselves correctly. In addition, the pipe node to which they are attached will be moved along the pipe to accommodate the connector symbol, so that the total length of the pipe including the connector symbol remains the same.

Other off-sheet connector symbols should only be placed on pipes drawn horizontally or vertically. Such symbols do not orientate themselves automatically, and therefore the appropriate symbol should be used depending on the direction the pipe was drawn in (e.g. left to right or right to left).

• Associated Project Configuration Options Reducer symbols may be restricted so that they can only be inserted into pipes with specific codes and sizes. These are specified using the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program.

Specify the default positions and symbols used to represent flags (off-sheet connectors) in the Offsheet Connector Configuration Category.

• Instructions 1. Select an inline fitting symbol by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the line fitting will appear on the cross hairs. The Command prompt will display:

Indicate point for <chosen fitting>:

Pick a point in a line. 3. The Command prompt will then display:

Indicate point to show angle of <chosen fitting>:

If it is a two point symbol, pick a point along the line in either direction to set the angle.

12.18:30© 2011 AVEVA Solutions Ltd

Page 419: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. The Command prompt will then display:

Indicate point for <chosen fitting>:

Pick another point, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

8.4.8 Inserting Instruments (Balloons)

• Description General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

Instrument balloons are items in their own right, unlike the label balloons attached to instrument (control) valves. They may be placed independently or inserted into pipes, signal lines or process links.

System output boxes fall within this category, but differ in that they do not break into pipes, signal lines or process links.

Also within the category are conditioning devices, for example, I/P Converters. These must have an instrument owner in order to be inserted.

Logic boxes, interlocks and I/O Rockets are also categorised as instrument balloons.

Note: Pipes, signal lines and process links do not close automatically when inline instrument balloons are deleted

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

12.18:31© 2011 AVEVA Solutions Ltd

Page 420: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Errors An error message will be received if an attempt is made to assign more than one conditioning device to an instrument.

• Associated Project Configuration Options • The block name of instrument label balloon symbols is specified in the Label Balloon

Symbol field on the Instruments - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• The presence or absence of link lines is controlled by the Label Balloon Link Lines Off checkbox. Uncheck the checkbox to turn off link lines.

• Instructions 1. Select an instrument symbol by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the instrument balloon will appear on the cross hairs. The prompts that follow depend on the type of balloon selected, as shown in the following examples:

12.18:32© 2011 AVEVA Solutions Ltd

Page 421: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Conditioning Devices 3. For an I/P converter, the prompts are as follows:

Select instrument owner for I/P CONVERTER:

With the symbol already on the crosshairs, click on (select) the instrument associated with the I/P converter.

4. The Command prompt will then display:

Indicate point for I/P CONVERTER:

Pick a point for the converter itself.

Note: A guideline is dragged out to the converter from the selected point on the owner instrument.

- Instrument Indicator 5. For an Indicator, the prompts are as follows:

Indicate point for INSTRUMENT INDICATOR:

Pick a point for the balloon. 6. The Command prompt will then display:

Indicate point for Label Balloon:

This is an optional prompt, dependent on project configuration,

Pick a point for the label balloon. 7. The Command prompt will then display:

Indicate point for INSTRUMENT INDICATOR:

Place another balloon, or press Ctrl-C to end the command.

12.18:33© 2011 AVEVA Solutions Ltd

Page 422: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- I/O Rockets 8. For an I/O Rocket, the prompts will be:

Indicate point for I/O ROCKET:

Pick a point for the rocket. 9. The Command prompt will then display:

Indicate point to show angle of I/O ROCKET:

Pick another point to indicate the angle of the I/O Rocket. The ghosting will help the final placement to be visualised.

10. The Command prompt will then display:

Indicate point for I/O ROCKET:

Place another I/O rocket, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

Use the Creating Item Associations procedure to associate the I/O rocket with the chosen instrument.

If auto-labelling is on, the Labelling General Instruments procedure will then start automatically.

8.4.9 Inserting Flow Elements

• Description General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

The flow elements category includes symbols such as orifice plates, flow restrictors, flow straighteners, turbine meters etc.

All flow elements have mandatory label balloons and optional link lines. If necessary, the label balloon can be independently positioned and moved after the flow element has been placed, and the point at which it connects to the valve changed.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

12.18:34© 2011 AVEVA Solutions Ltd

Page 423: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Errors All symbols in this category must be inserted into a pipe, process link or signal line otherwise an error message will be received.

• Associated Project Configuration Options The presence or absence of link lines is controlled by the Label Balloon Link Lines Off checkbox on the Instruments - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• Instructions 1. Select a flow element symbol by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the flow element will appear on the cross hairs. The Command prompt will then display:

Indicate point for <chosen flow element>:

Pick a point for placement. 3. The Command prompt will then display:

Indicate point for label balloon:

Place the label balloon.

12.18:35© 2011 AVEVA Solutions Ltd

Page 424: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. The Command prompt will then display:

Indicate point for label balloon link line (<ret> to connect to item insert point):

Press Enter to attach the link line to the insert point of the flow element, or place the connection point "manually" by clicking on the required point. This is an optional prompt, dependent on project configuration.

5. The Command prompt will then display:

Indicate point for <chosen flow element>:

Place another flow element, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

8.4.10 Inserting Miscellaneous Symbols

• Description General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

As the category name suggests, entities or elements which do not fall conveniently into the other categories may be placed here. For example, vessel jackets, revision triangles, electrical connections, hexagons.

The category also includes equipment of the EDL (Equipment Data Location) item type.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

12.18:36© 2011 AVEVA Solutions Ltd

Page 425: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Instructions 1. Select the symbol category by:

• using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the miscellaneous symbol will appear on the cross hairs. The Command prompt will then display (for example):

Indicate point for PRESSURE VESSEL JACKET:

Place the vessel jacket around the vessel. 3. The Command prompt will then display:

X scale factor:

Enter an X scale factor, e.g. 2 for double the original size. 4. The Command prompt will then display:

Y scale factor <defaults to X>:

Press Enter to scale the jacket evenly or enter a Y scale factor.

12.18:37© 2011 AVEVA Solutions Ltd

Page 426: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

5. The Command prompt will then display:

Rotation Angle <0.00>:

Enter a rotation angle, if necessary. 6. The Command prompt will then display:

Indicate point for PRESSURE VESSEL JACKET:

Place another symbol, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

8.4.11 Inserting Assemblies

• Description This procedure is used to insert assemblies. Three types of assembly may be created:

• Graphical Assemblies - pipes and symbols collected together into an AutoCAD block to act as templates, retaining the item associations

• Design Data Templates - collections of VPE Workbench or P&ID Data Grid designators and values used to label items.

• Annotation Assemblies - there are two sub-types of Annotation Assemblies:• Pipe: collections of pipe labels and symbols used to annotate pipes• UDA: collections of user-defined attribute labels and symbols used to annotate

pipes, instruments and equipment.

Assemblies are created using a separate procedure. See 8.9.1: Creating Assemblies.

General points on the procedure are given under 8.4.1: Inserting Symbols - General Information.

Note: When a block drawn in one pipe style is inserted into pipes drawn in another style, all entities change colour appropriately. Also when an assembly is used on a new project, all layers etc. are updated automatically to suit any new conventions.

For details of the use of this command in the context of drawing P&IDs, see 6.5: Inserting Symbols and 6.14: Assemblies.

Note: Instead of inserting symbols, new symbols can be placed on the drawing by copying and pasting existing symbols. See 8.7.1: Copying Drawing Objects and Labels for details.

• Instructions• Inserting a Graphical Assembly• Inserting a Design Data Template• Inserting an Annotation Assembly

12.18:38© 2011 AVEVA Solutions Ltd

Page 427: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Inserting a Graphical Assembly

1. Select the assembly by: • using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the assembly will appear on the cross hairs. The Command prompt will then display (for example):

Indicate point for TWO DIAPHRAGM ACTUATED VALVES:

Pick an appropriate point for insertion taking into account whether or not the assembly breaks into pipes.

3. The Command prompt will then display:

Indicate point for TWO DIAPHRAGM ACTUATED VALVES:

Pick an insertion point for another copy of the assembly, or select Cancel from the drawing page menu or press Ctrl-C to end the command..

- Inserting a Design Data Template

1. Select the assembly by: • using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the assembly will appear on the cross hairs. The Command prompt will then display (for example):

Indicate point for INS DDT 1:

Pick an appropriate point for insertion. 3. The Command prompt will then display:

Select Instrument:

Select the item that the DDT assembly is to be associated with if the DDT type is Instrument, Pipe, or Equipment, or select the drawing if the type is Drawing. DDTs must be associated with the appropriate entity.

The Command prompt will then display:

Indicate point for INS DDT 1:

Pick an insertion point for another copy of the assembly, or select Cancel from The Drawing Page menu or press Ctrl-C to end the command.

12.18:39© 2011 AVEVA Solutions Ltd

Page 428: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

VPE Workbench values displayed as part of the DDT will automatically updated when VPE Workbench data is refreshed to reflect the VPE Workbench properties of the item, or project if the DDT is labelling a drawing. See 8.8.11: Refreshing VPE Workbench Data.

Values from the P&ID Data Grid may also be refreshed. See 8.6.23: Refreshing P&ID Data Grid Labels.

Where a DDT is linked to a drawing, and that drawing is associated with a VPE Workbench project that includes multiple sub-projects, all sub-project data is displayed on the drawing. The layout of this data on the P&ID is controlled in the VPE Drawing Attributes section of the Drawing - Labels Sub-Set of the AVEVA P&ID Project Administrator program.

- Inserting an Annotation Assembly

1. Select the assembly by: • using the Symbol Explorer, or • using the AVEVA P&ID Tool Palette.

2. After the symbol has been selected a 'ghosted' image of the assembly will appear on the cross hairs. The Command prompt will then display (for example):

Specify insertion point for placing the assembly:

Pick an appropriate point for insertion. 3. The Command prompt will then display (for example):

Select the pipe segment to associate the label:

Select the pipe segment, instrument or equipment that the assembly is to annotate. The label component of the assembly will then automatically adopt the properties of the selected segment.

8.4.12 Inserting Unassigned P&ID Database Symbols

• Description The Unassigned node under the AVEVA P&ID Database node of the P&ID Data Grid lists items (equipment and instruments), created in P&ID Reports, that have not been added to a project drawing. Such items may be added to a drawing using facilities provided by the P&ID Data Grid.

Note: Unassigned pipes are also listed. For the procedure for inserting unassigned pipes, see 8.5.2: Inserting Unassigned P&ID Database Pipes.

For details of the use of this procedure in the context of drawing P&IDs, see 6.6: Inserting Unassigned P&ID Database Items.

12.18:40© 2011 AVEVA Solutions Ltd

Page 429: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by opening the P&ID Data Grid and accessing the Unassigned

node under the AVEVA P&ID Database node. 2. The Equipment and Instruments nodes list all unassigned equipment and instruments

by type. Select the required item so that its details are displayed in the right-hand window of the grid interface.

3. Right-click on the record in the right-hand window and select Insert from the menu that is then displayed:

4. The command prompt will then display:

Indicate point:

Pick an appropriate point for insertion. 5. The equipment or instrument is then placed on the drawing and labelled automatically

with the properties of the item as specified in AVEVA P&ID Reports. The symbol used will be that specified for the item in AVEVA P&ID Reports.

The item is moved from under the Unassigned node to under the Assigned node in the P&ID Data Grid.

8.4.13 Inserting Unassigned VPE Workbench Items

• Description Unassigned VPE Workbench items are equipment and instrument items in the associated VPE Workbench database that have not yet been placed on a project P&ID. If this facility is in use for a project (see below), the items are listed under the Unassigned node in the Engineering Explorer.

For details of the use of this procedure in the context of drawing P&IDs, see 6.7: Inserting Unassigned VPE Workbench Items.

• Associated Project Configuration Options Whether or not the Unassigned node is displayed is controlled by an option on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by either:

• selecting the Insert option from the shortcut menu of the unassigned item in the Engineering Explorer, or

• dragging and dropping the item from the Engineering Explorer onto The Drawing Page.

12.18:41© 2011 AVEVA Solutions Ltd

Page 430: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. If the item has not been assigned a symbol, it must be assigned at this point. The item may already have been assigned a symbol, either in the database or by accessing the Properties dialog from the Engineering Explorer.

If there are symbols associated with the item type of the item, the AVEVA P&IDUnassigned Equipment Properties dialog for the item is displayed (see 4.8: Properties Dialogs). For example:

Select the required symbol name from the list available in the Symbol Name field and click OK. This list consists of those symbol names previously assigned to items with the same item type as the unassigned item.

12.18:42© 2011 AVEVA Solutions Ltd

Page 431: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. If there are no symbols assigned to the item type of the item, the Symbol List dialog box is displayed.

Select the required symbol and click OK. 4. A 'ghosted' image of the item will appear on the cross hairs and may be placed on the

drawing as required. For further information, refer to the appropriate symbol insertion procedure, bearing in mind that only the single symbol representing the item may be inserted: • 8.4.2: Inserting Equipment (start from step 2)• 8.4.3: Inserting Electrical Equipment (start from step 2)• 8.4.4: Inserting Nozzles (start from step 2)• 8.4.5: Inserting Valves (start from step 2)• 8.4.6: Inserting Instrument Valves (Control Valves) (start from step 2)

12.18:43© 2011 AVEVA Solutions Ltd

Page 432: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• 8.4.7: Inserting Inline Fittings (start from step 2)• 8.4.8: Inserting Instruments (Balloons) (start from step 2)• 8.4.9: Inserting Flow Elements (start from step 2)• 8.4.10: Inserting Miscellaneous Symbols (start from step 2)

12.18:44© 2011 AVEVA Solutions Ltd

Page 433: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.5 Drawing Pipes and Connections

8.5.1 Drawing Pipes

• Description This procedure is used to draw pipes.

Pipes are drawn in the current style and with the current tracing and end styles. These can be set using the Pipes toolbar. Pipe styles are created and amended by selecting the Pipe Styles option on the List of Values Configuration Category of the AVEVA P&ID Project Administration program.

Note: A Process Link pipe style is available. Pipes drawn using this method will look like Process Links but will functionally be Pipes.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Associated Project Configuration Options • If pipes are to be broken automatically when crossed, the Automatic Breaks ON

checkbox, on the Pipes - Settings Sub-Set of the AVEVA P&ID Project Administration program must be checked.

• The break priority, i.e. whether the horizontal or vertical pipe is broken where a break occurs, is set using the Break Pipe Direction buttons.

• The width of the gap in a broken pipe is set in the Break Distance field. • The symbol chosen to represent the break is selected in the Symbol Name field. • The layer into which break symbols are placed is specified in the Symbol Layer field. • Layers are configured using the Drawing - Layers Sub-Set. • The colour of the break symbol is set in the Symbol Colour field. • If flow arrows are to be automatically placed at direction change points, ensure that the

Automatic Arrows checkbox on is checked. • Specify the symbol to be used to represent a flow arrow in the Symbol Name field. • Specify the default positions and symbols used to represent flags (off-sheet

connectors) in the Flags section.

• Instructions 1. Start the procedure by either:

• selecting the Draw Pipeline option in the Pipeline Group of the Home Tab, or • dragging and dropping from the AVEVA P&ID Tool Palette.

2. The Command prompt will then display:

Indicate point for pipe:

Place one end of the pipe.

12.18:45© 2011 AVEVA Solutions Ltd

Page 434: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The Command prompt will then display:

Indicate point for pipe:

Place other the end of the pipe or the first turning point. The length of pipe then appears on the drawing.

If a pipe flag (off-sheet connector) was selected as the pipe end style for the beginning of the pipe, it will be inserted and orientated automatically.

AVEVA P&ID will continue to prompt for end or turning points. Continue placing these until the pipe is finished.

4. The Command prompt will then display:

Indicate point for pipe:

5. Press or select Enter to end the command.

If a pipe flag (off-sheet connector) was selected as the pipe end style for the end of the pipe, it will be inserted and orientated automatically.

If auto-labelling for pipes is on, the Labelling Pipes procedure will then start automatically.

If both auto-labelling and auto-validation are on, the Labelling Pipes procedure will then start automatically.

Pipe end styles are selected, and auto-labelling and auto-validation are switched on and off using facilities in the Pipeline Group of the Home Tab.

8.5.2 Inserting Unassigned P&ID Database Pipes

• Description The Unassigned node under the AVEVA P&ID Database node of the P&ID Data Grid lists pipes, created in P&ID Reports, that have not been added to a project drawing. Such pipes may be added to a drawing using facilities provided by the P&ID Data Grid.

Note: Unassigned equipment and instruments are also listed. For the procedure for inserting such unassigned items, see 8.4.12: Inserting Unassigned P&ID Database Symbols.

For details of the use of this procedure in the context of drawing P&IDs, see 6.6: Inserting Unassigned P&ID Database Items.

• Instructions 1. Start the procedure by opening the P&ID Data Grid and accessing the Unassigned

node under the AVEVA P&ID Database node. 2. The Pipes nodes list all unassigned pipes. Select the required pipe so that its details

are displayed in the right-hand window of the grid interface.

12.18:46© 2011 AVEVA Solutions Ltd

Page 435: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. Right-click on the record in the right-hand window and select Draw from the menu that is then displayed:

4. The command prompt will then display:

Indicate point for Main Pipe:

Place one end of the pipe. 5. The Command prompt will then display:

Indicate point for Main Pipe:

Place other the end of the pipe or the first turning point. A preview of that segment of the pipe then appears on the drawing.

If a pipe flag (off-sheet connector) was selected as the pipe end style for the beginning of the pipe, it will be inserted and orientated automatically.

AVEVA P&ID will continue to prompt for end or turning points. Continue placing these until every segment of the pipe is drawn.

6. The Command prompt will then display:

Indicate point for Main Pipe:

Press or select Enter.7. The Command prompt will then display:

Insert pipe label:

Pick a position for the pipe label. The pipe label will then be placed, comprised of the properties of the pipe as specified in AVEVA P&ID Reports.

8. The Command prompt will then display:

Pick a point on Entity:

Select the pipe to complete the procedure.

12.18:47© 2011 AVEVA Solutions Ltd

Page 436: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The pipe is moved from under the Unassigned node to under the Assigned node in the P&ID Data Grid.

8.5.3 Drawing Process Links

• Description This procedure is used to draw process links between instrument items and process items, for example, a connection between a pressure indicator and a pipe or equipment item. Such links do not receive a line number.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

If Instrument Process Links, also known as "Legacy" Process Links, are to be used (the PLK item type), i.e. Process Links without the functionality introduced with AVEVA VPE P&ID 7.2 SP3, a number of factors should be considered when drawing process links if data is to be exported to an XML file in the ISO 15926 schema format. For details, see Guidelines for Drawing Process Links.

Note: If required, main pipes can be drawn using the Process Links pipe style. Pipes drawn using this method will look like Process Links but will functionally be Pipes. See 8.5.1: Drawing Pipes for the procedure.

• Associated Project Configuration Options The default style of Process Links is specified on the Settings Sub-Set pane of the AVEVA P&ID Project Administration program.

If only Instrument Process Links, also known as "Legacy" Process Links, are to be used, i.e. Process Links without the functionality introduced with AVEVA VPE P&ID 7.2 SP3, the Use Legacy Process Link checkbox on the Pipes – Settings Sub-Set must be checked.

The default style of Instrument Process Links is specified on the Pipes – Settings Sub-Set.

Note: Non-"Legacy" Process Links are drawn using the pipe item type (PMA) in the process link pipe style. In other words they will technically be branches between main pipes and offline items. They will therefore have all the functionality of pipes and may be labelled and edited in the same way.

12.18:48© 2011 AVEVA Solutions Ltd

Page 437: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Instructions • Drawing Process Links• Drawing Instrument Process Links

- Drawing Process Links

Note: Before starting, ensure that the Use Legacy Process Link checkbox on the Pipes – Settings Sub-Set of the AVEVA P&ID Project Administration program is unchecked, otherwise Instrument Process Links, also known as "Legacy" Process Links will be drawn.

1. Start the procedure by either: • selecting the Process Link option in the Pipeline Group of the Home Tab, or• dragging and dropping from the AVEVA P&ID Tool Palette.

2. The Command prompt will display:

Indicate point for Process Link:

Pick the start point for the Process Link.

12.18:49© 2011 AVEVA Solutions Ltd

Page 438: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The Command prompt will then display:

Indicate point for Process Link:

Pick the end point for the Process Link.

Keep selecting start/end points for further Process Links, or press or select Enter to finish the command.

For process links drawn using the PMA (pipe) item type, the Labelling Pipes procedure will NOT start automatically even auto-labelling for pipes is on. The labelling procedure for such process links may be started manually if required.

- Drawing Instrument Process Links

Note: If the Use Legacy Process Link checkbox on the Settings Sub-Set pane of the AVEVA P&ID Project Administration program is checked, the above procedure may also be used.

1. Start the procedure by selecting the Instrument Link option in the Pipeline Group of the Home Tab.

2. The Command prompt will display:

Indicate point for Multilined Process Link:

Pick the start point for the instrument process connection.3. The Command prompt will then display:

Indicate point for Multilined Process Link:

Pick the end point for the instrument process connection.

Keep selecting start/end points for further Process Links, or press or select Enter to finish the command.

12.18:50© 2011 AVEVA Solutions Ltd

Page 439: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Guidelines for Drawing Process LinksIf "Legacy" Process Links are to be used (PLK item type), i.e. Process Links without the functionality introduced with AVEVA VPE P&ID 7.2 SP3, a number of factors should be considered when drawing process links if data is to be exported to an XML file in the ISO 15926 schema format.

Because of the limitations of the ISO 15926 schema not all arrangements of process links are supported, therefore the following guidelines must be followed to ensure an accurate layout of pipe networks is available for the 2D-3D comparison performed by the P&ID 3D Integrator.

- Tees or any in-line components that split the flow should not be drawn with process links, e.g.:

In-line components that split the flow are: • 3 way and 4 way fittings • Valves and in-line equipment • Port valves with more than two ports.

12.18:51© 2011 AVEVA Solutions Ltd

Page 440: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Instead, as in this example, the bypass should be drawn as branch of the main pipe, like so:

- Process links should not be connected directly to equipment:

Ideally any tubing connected to a vessel should be a branch of a trim pipe, and at the very least they should start from a nozzle:

12.18:52© 2011 AVEVA Solutions Ltd

Page 441: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Process links should not be used as leader lines or to connect any items that are not meant to be part of a pipe network:

Signal lines or dummy lines should be used instead:

8.5.4 Changing Pipe Styles

• Description This procedure is used to change pipes or process links to the current pipe/link style. Set the pipe style required first using facilities in the Pipeline Group of the Home Tab.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions 1. To change the style of pipes to the current pipe style, start the procedure by selecting

the Change Style option in the Pipeline Group of the Home Tab.2. The Command prompt will display:

Select Objects:

Pick the pipes or links the style of which is to be changed and press or select Enter.

12.18:53© 2011 AVEVA Solutions Ltd

Page 442: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.5.5 Applying Tracing to Pipes

• Description This procedure is used to apply tracing to existing pipes. Any inline fittings shown are automatically traced around. Tracing is applied to entire pipes. If tracing is not required for a segment of pipe, that segment of tracing can subsequently be deleted.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.3: Tracing Lines.

• Instructions 1. Start the procedure by selecting the Add Trace option in the Pipeline Group of the

Home Tab.2. The Command prompt will display:

Select pipe for trace:

The selected pipe is then traced. 3. The Command prompt will then display:

Select pipe for trace:

Select further pipes until all required tracing is in place. Press or select Enter to end the command.

8.5.6 Drawing Signal Lines

• Description This procedure is used to draw signal lines. The procedure ends automatically when the signal line reaches an instrument.

Signal lines are drawn in the current signal line style as set using facilities in the Pipeline Group of the Home Tab.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.2: Drawing Signal Lines.

12.18:54© 2011 AVEVA Solutions Ltd

Page 443: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Associated Project Configuration Options • The default drawing layers and colours for signal line item types are set up on the Item

Types - Signal Sub-Set. • The default signal line style is specified in a field of that name in the Signal Styles

Configuration Category of the AVEVA P&ID Project Administration program. This pane can also be used to configure and create the signal line styles.

• Instructions 1. Start the procedure by either:

• selecting the Draw Signal option in the Signal Line Group of the Home Tab, or • dragging and dropping from the AVEVA P&ID Tool Palette.

2. The Command prompt will display:

Indicate point for Signal Line:

Pick the start point of line. 3. The Command prompt will then display:

Indicate point for Signal Line:

Pick a turning point or the end point. Press or select Enter to continue or press Ctrl-C or select Cancel to finish the command.

8.5.7 Changing Signal Line Styles

• Description This procedure is used to change the style of existing signal lines.

Before using this procedure, select the style that the signal lines are to be changed to using facilities in the Signal Line Group of the Home Tab.

12.18:55© 2011 AVEVA Solutions Ltd

Page 444: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.2: Drawing Signal Lines.

• Instructions 1. Start the procedure by selecting the Change Style option in the Signal Line Group of

the Home Tab.2. The Command prompt will display:

Select signal line to change to XXX:

(where 'XXX' is the currently loaded style).

Select each signal line in turn to change the signal line style. The style of each line changes dynamically as it is selected.

3. Press or select Enter to end the command.

8.5.8 Breaking LinesPipes, signal lines and process links may be broken automatically when crossed. However, "manual" breaks may be entered if required using this procedure.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections and 6.8.2: Drawing Signal Lines.

• Associated Project Configuration Options • Whether or not pipes are to be broken automatically when crossed is controlled by the

Automatic Breaks ON checkbox on the Pipes - Settings Sub-Set of the AVEVA P&IDProject Administration program.

• The symbol chosen to represent the break is selected in the Symbol Name field. • The layer into which break symbols are placed is specified in the Symbol Layer field.

• Instructions 1. Start the procedure by:

• selecting the line to be broken on The Drawing Page, then right-clicking and selecting Break from the shortcut menu, or

• selecting the line to be broken on the drawing page, then selecting the Break option in the Modify Group of the Home Tab.

2. The Command prompt will display:

Pick a first point on the pipeline:

Pick the point on the line where the break starts. 3. The Command prompt will then display:

Pick a second point on the same pipeline:

12.18:56© 2011 AVEVA Solutions Ltd

Page 445: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pick the point on the line where the break ends 4. The line is then broken.

8.5.9 Merging Pipes, Branches and Signal Lines

• Description This procedure is used to merge two main pipes into one main pipe, or two branches into one branch, or to merge a branch into a main pipe, or to merge two signal lines into one signal lines

The pipes/branches/signal lines to be merged must adjoin each other.

When pipes or branches are merged, the properties of the first pipe/branch selected (as described below) are adopted as the properties of the merged pipe/branch.

To merge two segments of a single pipe together, see 8.5.14: Merging Pipe Segments.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions 1. Start the procedure by either:

• selecting the pipe/branch into which the other pipe/branch is to be merged on The Drawing Page, then right-clicking and selecting Pipes>Merge from the shortcut menu (this option is not available for signal lines), or

• selecting the Merge Branch/Pipe option in the Modify Group of the Home Tab.2. If the second method of starting the procedure is selected, the Command prompt will

display:

Pick a pipe group to merge:

Pick the pipe/branch/signal line into which the other pipe/branch is to be merged.

If the first method of starting the procedure is selected, a pipe/branch will already have been selected.

3. The Command prompt will display:

Pick a different pipe group to merge:

Pick the pipe/branch/signal line that is to be merged into the first pipe/branch selected.4. The two selected pipe/branch/signal line are then merged. If pipes or branches are

merged, the properties of the first pipe/branch selected are adopted as the properties of the merged pipe/branch.

8.5.10 Splitting Pipes and Signal Lines

• Description This procedure is used to split a pipe or signal line into two separate pipes or signal lines.

12.18:57© 2011 AVEVA Solutions Ltd

Page 446: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

In the case of pipes, the properties of the previously unsplit pipe are assigned to the new pipe located before the split in terms of the pipe flow of the unsplit pipe. These properties are also assigned to the new pipe after the split, except for those properties which are required to be unique, which are replaced by the project null symbol (e.g. "?").

To split a section of a pipe of as a branch of that pipe, see 8.5.11: Splitting off Branches.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Example

The white section of the line indicates where it has been split.

• Instructions 1. Start the procedure by either:

• selecting the pipe to be split on The Drawing Page, then right-clicking and selecting Pipes>Split to Main from the shortcut menu (this option is not available for signal lines), or

• selecting the Split To Main Pipe option in the Modify Group of the Home Tab.2. If the second method of starting the procedure is selected, the Command prompt will

display:

Pick a pipe group to split:

Pick the pipe or signal line that is to be split.

If the first method of starting the procedure is selected, a pipe will already have been selected.

12.18:58© 2011 AVEVA Solutions Ltd

Page 447: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The Command prompt will display:

Pick a point on pipe joint to split the selected pipe joint:

Pick the point on the pipe or signal line where the split is to occur. Note that a pipe must have been labelled on both sides of the select split point.

4. The pipe or signal line is then split at the selected point into two new pipes or signal lines.

If a pipe is split, the properties of the previously unsplit pipe are assigned to the new pipe located before the split in terms of the pipe flow of the unsplit pipe. These properties are also assigned to the new pipe after the split, except for those properties which are required to be unique, which are replaced by the project null symbol (e.g. "?").

8.5.11 Splitting off Branches

• Description This procedure is used to split a section of a pipe off as a branch of that pipe.

The properties of the pipe are automatically assigned to the new branch.

To split a pipe into two separate pipes, see 8.5.10: Splitting Pipes and Signal Lines.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Example

The white section of the pipe indicates where it has been split.

• Instructions 1. Start the procedure by either:

• selecting the pipe to be split on The Drawing Page, then right-clicking and selecting Pipes>Split to Branch from the shortcut menu, or

• selecting the Split Branch Pipe option in the Modify Group of the Home Tab.2. If the second method of starting the procedure is selected, the Command prompt will

display:

Pick a pipe group to split:

Pick the pipe that off which a branch is to be split.

12.18:59© 2011 AVEVA Solutions Ltd

Page 448: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the first method of starting the procedure is selected, this pipe will already have been selected.

3. The Command prompt will display:

Pick a point on pipe joint to split the selected pipe joint:

Pick the point on the pipe where the split is to occur. The section of the pipe after the split in terms of pipe flow will be the new branch. Note that the pipe must be labelled on both sides of the select split point.

4. The branch is then split off of the pipe at the selected point.

The properties of the pipe are automatically assigned to the new branch.

8.5.12 Reversing Pipe and Signal Line Flows

• Description This procedure is used to reverse the flow of a pipe or a signal line.

Note that reversing the flow of a pipe will not reverse the flow of a branch that loops off and then back onto a pipe. Reversing the flow of a branch will not reverse the flow of the owning main pipe.

Signal lines do not have flows in a process sense. The procedure is used to reverse the direction in which a signal line is drawn.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions1. Start the procedure by either:

• selecting the pipe to be split on The Drawing Page, then right-clicking and selecting Pipes>Reverse Flow from the shortcut menu (this option is not available for signal lines), or

• selecting the Reverse Flow option in the Modify Group of the Home Tab.2. If the second or third method of starting the procedure is selected, the Command

prompt will display:

Pick a pipe groups to reverse flow:

Pick the pipe or signal line the flow of which is to be reversed.

If the first method of starting the procedure is selected, a pipe will already have been selected.

3. The flow of the selected pipe or signal line is then reversed. The pipe is automatically redrawn to reflect this, i.e. the flow arrows change direction and the start and end nodes swap ends. In the case of signal lines, any symbols that are part of the line change direction.

12.18:60© 2011 AVEVA Solutions Ltd

Page 449: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Labels on either side of a spec break, both on the pipe and on the break symbol, are also updated automatically: the pipe property that is different on either side of the break changes from one side of the break to the other, and the labels are changed to reflect this.

Reducers in pipes change direction if the pipe flow is reversed. However the labels of reducers do not. They must be rotated manually.

8.5.13 Adding Pipe and Signal Line Segments

• Description This procedure is used to add new segments to the either end of a pipe or signal line. Segments can also be extended from ports on inline item symbols.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions1. Start the procedure by either:

• selecting the first or last segment of the pipe that is to be have a segment added to it on The Drawing Page, then right-clicking and selecting Segments>Add from the shortcut menu (this option is not available for signal lines), or

• if a segment is to be extended from a port on an inline item symbol, by selecting that symbol on The Drawing Page, then right-clicking and selecting Segments>Add from the shortcut menu, or

• selecting the Add Segment option in the Modify Group of the Home Tab.2. If the third method of starting the procedure is selected, the Command prompt will

display:

Select pipeline or symbol port to add segment to the end:

Pick the first or last segment of the pipe or signal line that is to have a segment added to it. If a segment is to be extended from a port on an inline item symbol, select that symbol.

If the first or second method of starting the procedure is selected, a pipe or symbol will already have been selected.

3. The Command prompt will display:

Indicate next vertex or start point of successive pipe or port of successive symbol for adding segment:

Select the end-point of the new segment. This can be the start of another pipe or signal line, or the port of another inline item symbol.

4. If the start of another pipe/signal line or the port of another inline item symbol is selected, the new segment is drawn and the command ends.

12.18:61© 2011 AVEVA Solutions Ltd

Page 450: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the new segment does not end on another pipe, signal line or port, either press Enter to draw the new segment and end the command, or add another segment by indicating the end point of this segment as described above.

Repeat until all required segments are defined, then press Enter to draw these new segments and end the command.

8.5.14 Merging Pipe Segments

• Description This procedure is used to merge pipe segments into a single segment. Both segments must be of the same pipe.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions1. Start the procedure by either:

• selecting a segment to be merged on The Drawing Page, then right-clicking and selecting Segments>Merge from the shortcut menu, or

• selecting the Merge Segment option in the Modify Group of the Home Tab.2. If the second method of starting the procedure is selected, the Command prompt will

display:

Pick a segment to merge:

Pick the segment into which the other segment is to be merged.

If the first method of starting the procedure is selected, this segment will already have been selected.

3. The Command prompt will display:

Pick a different segment to merge:

Pick the segment that is to be merged into the first pipe/branch selected. Both segments must be of the same pipe.

4. The two selected segments are then merged.

8.5.15 Deleting Pipe and Signal Line Segments

• Description This procedure is used to delete a segment from a pipe or a signal line.

Note this does not result in the pipe or signal line being split into two separate entities. A pipe or signal line with a segment deleted in this manner is still a single entity, even if it the two parts of the line are not visibly connected.

12.18:62© 2011 AVEVA Solutions Ltd

Page 451: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

To split a pipe or signal line into two separate pipes or signal lines, see 8.5.10: Splitting Pipes and Signal Lines.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions 1. Start the procedure by either:

• selecting the pipe segment that is to be deleted on The Drawing Page, then right-clicking and selecting Segments>Delete from the shortcut menu (this option is not available for signal lines), or

• selecting the Delete Segment option in the Modify Group of the Home Tab.2. If the first method of starting the procedure is selected, the selected pipe segment is

deleted.

If the second method of starting the procedure is selected, the Command prompt will display:

Select pipeline segment to delete:

Pick the pipe or signal line segment to be deleted.

The selected segment is then deleted.

8.5.16 Changing the Length of Lines

• Description This procedure is used to change the length of pipes, process links and signal lines. The procedure may also be used to change the orientation of the last segment of a pipe, process link or signal line.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions1. Start the procedure by either:

• selecting the pipe or process link to be extended on The Drawing Page, then right-clicking and selecting Extend from the shortcut menu (this option is not available for signal lines), or

• selecting the Extend Segment option in the Modify Group of the Home Tab.

12.18:63© 2011 AVEVA Solutions Ltd

Page 452: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. If the second method of starting the procedure is selected, the Command prompt will display:

Pick a pipeline to extend:

Pick the pipe, process link or signal line to be extended or shortened.

If the first method of starting the procedure is selected, a line will already have been selected.

3. The Command prompt will display:

Pick a point close to the pipeline to extend:

Pick the point on the drawing to which the line is to be extended or shortened to. The last segment of the line is then extended or shortened to that point.

If the point selected is at angle to the original orientation of the segment, the segment will be redrawn in this direction.

8.5.17 Adding Elbows to a Line

• DescriptionThis procedure is used to add and remove elbows to/from pipes, process links and signal lines. This has the effect of adding a new segment to the line.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions1. Start the procedure by either:

• selecting the pipe, process link or signal line segment to which an elbow is to be added on The Drawing Page, then right-clicking and selecting Segments>Elbowfrom the shortcut menu (this option is not available for signal lines), or

• selecting the Elbow Stretch option in the Modify Group of the Home Tab.2. If the second method of starting the procedure is selected, the Command prompt will

display:

Pick a pipe group to split:

12.18:64© 2011 AVEVA Solutions Ltd

Page 453: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pick the pipe, process link or signal line to which an elbow is to be added.

If the first method of starting the procedure is selected, a segment will already have been selected.

3. The Command prompt will display:

Pick a point to stretch:

Pick the point on the drawing to which the line is to be stretched to form the new elbow.

The new elbow is then created at the point. The segment to which the elbow has been added is now split into two segments at the elbow.

12.18:65© 2011 AVEVA Solutions Ltd

Page 454: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.5.18 Changing Pipes to Branches and Branches to Pipes

• Description This procedure is used to change main pipes into branches and branches into main pipes.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions• Changing Pipes to Branches• Changing Branches to Pipes

- Changing Pipes to Branches

1. Start the procedure by either: • selecting the Main to Branch Pipe option in the Modify Group of the Home Tab, or• selecting the pipe on The Drawing Page, selecting the Main to Branch Pipe option

in the Modify Group of the Home Tab.2. If the first method of starting the procedure is selected, the Command prompt will

display:

Pick a main pipe to convert as branch pipe:

Note that the pipe must be selected, not its label.

This step is omitted if the second method of starting the procedure is selected, as the pipe will already have been selected.

Select the pipe that is to be converted into a branch.3. The Command prompt will display:

Indicate owner pipe for branch, or Trim for Trim pipe (<ret for new pipe>):

Select the main pipe that is to be owner of the branch.

The pipe is then converted into a branch, with the selected pipe as its owner.

The ownership of any branches that the converted pipe owned is switched to the pipe selected to be the owner of the converted pipe.

12.18:66© 2011 AVEVA Solutions Ltd

Page 455: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Changing Branches to Pipes

1. Start the procedure by either: • selecting the Branch to Main Pipe option in the Modify Group of the Home Tab, or• selecting the pipe on The Drawing Page, selecting the Branch to Main Pipe option

in the Modify Group of the Home Tab.2. If the first two methods of starting the procedure are selected, the Command prompt

will display:

Pick a branch pipe to convert as main pipe:

Note that the branch must be selected, not its label.

This step is omitted if the third or fourth methods of starting the procedure are selected, as the branch will already have been selected.

The branch is then converted into a pipe.

8.5.19 Changing the Owning Pipes of Branches

• Description This procedure is used to change which pipe is the owner of a branch.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8: Drawing Pipes and Connections.

• Instructions1. Start the procedure by either:

• selecting the Change Pipe Owner option in the Modify Group of the Home Tab, or• selecting the pipe on The Drawing Page, selecting the Change Pipe Owner option

in the Modify Group of the Home Tab.2. If the first method of starting the procedure is selected, the Command prompt will

display:

Pick a branch pipe to change its owner pipe:

Note that the branch must be selected, not its label.

This step is omitted if the second method of starting the procedure is selected, as the branch will already have been selected.

Select the branch that is to be allocated to another pipe.3. The Command prompt will display:

Indicate owner pipe for branch, or Trim for Trim pipe (<ret for new pipe>):

Select the main pipe that is to be owner of the branch.

12.18:67© 2011 AVEVA Solutions Ltd

Page 456: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The ownership of the branch is then switched to the selected pipe.

8.5.20 Connecting Pipes to Nozzles and Equipment

• Description In order for nozzles and pipes to inherit sizes from each other, they must be part of the same pipe group.

To check whether a nozzle is part of a pipe group, hover the cursor over the nozzle on the drawing so that it becomes highlighted. If the pipe and its components do not also become highlighted, the nozzle is not part of the pipe group.

This procedure is used to add nozzles and other equipment to a pipe group.

Note: A facility is also available to remove nozzles and equipment from a pipe group. See 8.5.21: Disconnecting Pipes from Nozzles and Equipment.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.1: Drawing Pipes and Process Links and 6.10.16: Labelling Nozzles.

• Associated Project Configuration Options The Cascade Nozzle to Pipe checkbox on the Nozzles – Settings Sub-Set of the AVEVA P&ID Project Administration program controls whether or not sizes are cascaded between nozzles and pipes.

• Instructions1. Start the procedure by selecting the AVEVA Connect option in the Modify Group of the

Home Tab.2. The Command prompt will display:

Pick pipe group and equipment to connect:

Select either the nozzle or equipment, or pipe group it is to be connected to.3. The Command prompt will then again display:

Pick pipe group and equipment to connect:

Select the other item that is to be connected. It does not matter which is selected first.4. Press Enter. The Command prompt will then display:

Pick point on pipeline closest to the end to which equipment to be connected:

Select the end of the pipe to which the nozzle or equipment is to be connected.

The nozzle or equipment is now part of the pipe group, and connected to the selected end of the pipe.

12.18:68© 2011 AVEVA Solutions Ltd

Page 457: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.5.21 Disconnecting Pipes from Nozzles and Equipment

• Description Nozzles and pipes in the same pipe group may inherit sizes from each other. If this is not required for a particular pipe and nozzle, this procedure can be used to disconnect a pipe from a nozzle (or from equipment), so that they are no longer in the same pipe group.

To check whether a nozzle is part of a pipe group, hover the cursor over the nozzle on the drawing so that it becomes highlighted. If the pipe and its components also become highlighted, the nozzle is part of the pipe group.

Note: A facility is also available to add nozzles and equipment to a pipe group. See 8.5.20: Connecting Pipes to Nozzles and Equipment.

For details of the use of this procedure in the context of drawing P&IDs, see 6.8.1: Drawing Pipes and Process Links and 6.10.16: Labelling Nozzles.

• Associated Project Configuration Options The Cascade Nozzle to Pipe checkbox on the Nozzles – Settings Sub-Set of the AVEVA P&ID Project Administration program controls whether or not sizes are cascaded between nozzles and pipes.

• Instructions1. Start the procedure by selecting the AVEVA Disconnect option in the Modify Group of

the Home Tab.2. The Command prompt will display:

Pick pipe group and equipment to disconnect:

Select the nozzle or equipment to remove from the pipe group.

The nozzle or equipment is then removed from the pipe group.

12.18:69© 2011 AVEVA Solutions Ltd

Page 458: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6 Labelling Symbols and Pipes

8.6.1 Labelling - General Information

• DescriptionThis procedure is used for labelling placing 'Intelligence' such as tags and engineering data for pipes and symbols onto drawings. Points to note:

• Instruments and equipment may have either 4 or 6 tag fields, depending on the configuration of the project.

• In all cases, a '?' displayed in any of the drop-down lists used while labelling, indicates that this project definable null character may be selected where data is not yet known. All drop-down lists contain a list of acceptable values for that field, as defined in the online validation files. Data entered in these fields, or at the command prompt, is checked against these values if online validation is on.

• Item label fields may be set to inherit from drawing sheet attribute values.

See 6.10.23: Setting Labels to Inherit Values from Drawing Sheet Attributes.• Instrument and Equipment label fields that have been set to inherit from drawing sheet

attribute values can be "hidden", i.e. they will be displayed on Properties dialogs and included in any export of P&ID data, but will not appear on P&IDs or in the tag preview of Properties dialogs.

See 6.10.23: Setting Labels to Inherit Values from Drawing Sheet Attributes. • The project may be set to check that all labels in all P&IDs in a project are unique within

a category of item, for example, pipes or instruments. Depending on the project settings, the user may be prevented from entering duplicate labels, or permitted to enter such labels but warned that they are not unique in the project.

See 6.13.4: Label Validation across all Project P&IDs for details. • The project may also be set to check that entries are in a valid format, and to check

entries against lists of valid values.

See 6.13.2: Label Format Validation and 6.13.1: Label Validation against Lists of Valid Values for details.

• As well as the standard AVEVA P&ID attributes, user-defined attributes may be assigned to pipes and symbols. See 6.12: Adding User-Defined Attributes for details.

For details of the use of this command in the context of drawing P&IDs, see 6.10: Labelling Symbols.

Note: The current properties of pipes and items can be viewed on the drawing page by hovering the cursor over the symbol in question.

• ProceduresThe labelling procedure varies, depending on the type of item being labelled:

• 8.6.2: Labelling Using the Non-Modal Properties Dialog• 8.6.3: Labelling Equipment (with or without Trim)• 8.6.4: Labelling Electrical Equipment • 8.6.6: Labelling Nozzles • 8.6.7: Labelling General Valves • 8.6.9: Labelling Inline Fittings

12.18:70© 2011 AVEVA Solutions Ltd

Page 459: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• 8.6.8: Labelling Port Valves• 8.6.9: Labelling Inline Fittings • 8.6.10: Labelling Pipe Destination Fittings • 8.6.12: Labelling General Instruments • 8.6.13: Labelling System I/O Connections, Interlocks and Logic Boxes• 8.6.14: Labelling I/O Rockets• 8.6.15: Labelling Revision Triangles • 8.6.18: Labelling and Connecting Pipe Flags • 8.6.17: Labelling Pipes• 8.6.19: Labelling Reducers • 8.6.20: Labelling Breaks and Inline Breaks • 8.6.21: Adding Pipe Destination Text

See also: • 8.6.22: Labelling with Data from the P&ID Data Grid• 8.6.23: Refreshing P&ID Data Grid Labels• 8.6.24: Editing Non-AVEVA P&ID Text • 8.6.25: Labelling Typical Items • 8.6.27: Setting a Pipe Label as the Main Label• 8.6.28: Changing the Association of a Pipe Label• 8.6.29: Adding Notes to Items • 8.6.30: Globally Editing Labels • 8.6.31: Setting Symbols to Inherit Label Data from a Manually Selected Pipe• 8.6.32: Switching off Label Data Inheritance from Pipes• 8.6.33: Labelling Items with UDAs• 8.6.34: Removing UDAs from Symbols

• Associated Project Configuration Options • The units used for labels (metric or imperial) are selected using the Metric or Imperial

Label Units buttons on the Project Configuration Category. • The text of labels may either be in the default font select for the project on the Label

Types Configuration Category, or in the text style assigned to the label type, also set on the Label Types Configuration Category.

• Text styles are defined on the Text Styles Configuration Category. The text styles currently in use on a drawing can be viewed by accessing the AutoCAD Text Style dialog (type STYLE at the command prompt).

• The null character is specified in the Label Null Character field of this pane. • The default justification, height and rotation of text for labels are also specified on this

pane. • If data is to be validated as it is entered, ensure that the On-Line Data validation

checkbox is checked on the Miscellaneous - Settings Sub-Set. • The directory in which the validation files are maintained is specified in the Validation

Directory Path field on the Project Configuration Category. • Sheet attribute field names are set up using the Drawing Information - Settings pane. • The number of instrument and equipment tag fields, 4 or 6, is specified in the Number

of TAG fields sections of the Instruments - Settings Sub-Set and Equipment - Settings Sub-Set.

12.18:71© 2011 AVEVA Solutions Ltd

Page 460: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Inheritance between item label and sheet attribute fields, and whether or not inherited values are displayed on P&IDs, is set up using the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Line Fittings Configuration Category.

• Label validation across a project settings are made using the buttons in the Label Validation Across P&IDs sections of the Pipes - Validation Sub-Set, Instruments - Validation Sub-Set, Equipment - Validation Sub-Set, Valves - Validation Sub-Set and Miscellaneous - Validation Sub-Set.

• Label format validation settings are made using the Pipes - Validation Sub-Set, Instruments - Validation Sub-Set, Equipment - Validation Sub-Set, Valves - Validation Sub-Set and Miscellaneous - Validation Sub-Set

• Validation against lists of valid values is switched on and off on the Miscellaneous - Settings Sub-Set. The files containing the lists of values are edited using the List of Values Configuration Category.

• Whether or not auto-labelling is on by default is set on the Miscellaneous - Labels Sub-Set pane.

• Typical labelling is switched on or off using the Typical Labelling checkbox of this pane. The colours of typical pipes, pipe flags, instruments, equipment, SPPs and valves are also selected on this pane.

• To set the last value entered in a Properties dialog field to automatically populate that field that next time that Properties dialog is accessed for an unlabelled item of that item type, use the Pipes - Settings Sub-Set, Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Miscellaneous - Settings Sub-Set.

• For validation purposes, label data can be automatically transferred to an SQL database on entry if the Save to database on Update checkbox on the VPE Workbench Configuration Category is checked. The database location is specified on the Project Configuration Category. See 6.13.4: Label Validation across all Project P&IDs.

8.6.2 Labelling Using the Non-Modal Properties Dialog

• Description Labels can be viewed and entered using the non-modal Properties dialog.

Note that tags, pipe sizes, instrument types and other validated data cannot be directly entered or changed using this dialog. However, modal Properties dialogs can be accessed from the non-modal Properties dialog, in which the required values must be entered.

Other details can be entered or changed, and the drawing labelled with them.

• Instructions1. Start the procedure by opening the non-modal Properties dialog, if it is not already

open. To open the non-modal Properties dialog, select the P&ID Properties option in Properties Group of the Home Tab.

12.18:72© 2011 AVEVA Solutions Ltd

Page 461: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. The non-modal Properties dialog automatically displays details of whichever item is currently selected, or details of the drawing if nothing is selected.

3. The non-modal Properties dialog displays all the properties of the item, including UDAs etc, on a single tab.

4. Enter the required details/

12.18:73© 2011 AVEVA Solutions Ltd

Page 462: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

5. Tags, pipe sizes, instrument types and other validated data cannot be entered or changed using this dialog. A button in each tag field opens a modal Properties dialog, in which the required values must be entered.

The modal dialog will include a field for all the data of the item that cannot be modified in the non-modal dialog.

6. Drawings can be labelled from the non-modal dialog by hovering the mouse over the value in the Properties dialog that the drawing is to be labelled with, then moving the cursor over the drawing. The user will then be prompted to pick a point to place the label.

8.6.3 Labelling Equipment (with or without Trim)

• Description The procedure can be used to label Equipment (with or without trim), or for editing an existing equipment label.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.5: Labelling Equipment.

12.18:74© 2011 AVEVA Solutions Ltd

Page 463: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Associated Project Configuration Options • If equipment data is to be imported from VPE Workbench, by use of the EDL item type,

the Import Equipment Data checkbox in the Equipment Data from VPE Workbenchsection of the Equipment - Settings Sub-Set must be checked. The placing of the imported data information is specified by the Column 'X' and Row 'Y' Offsets fields in this section.

• The number of equipment label fields, 4 or 6, is specified in the Number of TAG fields section of the Equipment - Settings Sub-Set.

• The boilerplate text to replace the defaults of Block, Function, Prefix, Tag, Number and Suffix in the Equipment properties dialog is specified in the Dialog Box Field labels section of the Equipment - Settings Sub-Set.

• To set the last value entered in a Properties dialog field to automatically populate that field that next time that Properties dialog is accessed for an unlabelled item of that item type, use the checkboxes in the Values to Remember from Last Equipment Edit and Values to Remember from Last In-Line Equipment Edit sections of the Equipment - Settings Sub-Set.

• Inheritance between equipment label and sheet attribute fields, and whether or not inherited values are displayed on P&IDs, is set up using the Equipment - Settings Sub-Set.

• The project may be set to check that equipment labels in all P&IDs in the project are unique using the Label Validation across P&IDs section of the Equipment - Settings Sub-Set.

12.18:75© 2011 AVEVA Solutions Ltd

Page 464: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Whether or not delimiters are required after fields in an equipment label is specified in the Label Format section of the Equipment - Labels Sub-Set. The delimiters to be used are chosen in the same section.

• Whether or not fixed equipment label formatting is in use, and the coordinates of label components if it is not, are specified in the Equipment Label Position and In-Line Equipment Label Position sections of the Equipment - Labels Sub-Set.

• The display order of fields in equipment labels is specified in the Equipment Label Format section of the Equipment - Labels Sub-Set.

• The project may be set to require that a selected field or a combination of fields in equipment labels be unique (in addition to the entire label being unique). The fields that are checked for uniqueness are selected in the Unique Tags section of the Equipment - Labels Sub-Set.

• Equipment labels may automatically have a symbol placed with them when they are inserted. For example, they may be placed in a box. This functionality is switched on and off, the required symbol selected, and the offset from the label specified using the Equipment Label Symbol and In-Line Equipment Label Symbol sections of the Equipment - Labels Sub-Set.

• The fields that are to be checked for uniqueness are selected on the Pipes - Labels Sub-Set, Instruments - Labels Sub-Set and Equipment Labels panes of the AVEVA P&ID Project Administration program.

• Automatic tagging of equipment number fields (see 6.10.25: Automatic Tagging) is switched on and formatted on the Equipment - Automatic Tag Format Sub-Set.

• If it is required that the design area is used as the prefix for the equipment, the Design area from Title Block used for Instrument Label Field 1 checkbox has been checked in the Drawing - Labels Sub-Set.

• Inheriting Label Data from the Owning Pipe Label Inline equipment label data may be inherited from the label of the owning pipe, as set-up on the Equipment - Settings Sub-Set of the AVEVA P&ID Project Administration program. For details of setting up the inheritance, see 8.6.31: Setting Symbols to Inherit Label Data from a Manually Selected Pipe.

If an inline equipment item has the inherited values in its label edited using the procedure below, this will cancel the inheritance.

• Instructions 1. The procedure may start automatically if auto-labelling for equipment is on. If this is the

case, the AVEVA P&ID Equipment Properties dialog displays automatically when the equipment is placed on the drawing (see below).

If auto-labelling is not on, or to edit an existing label, start the procedure by either: • selecting the symbol to be labelled on The Drawing Page, then selecting

Properties from the shortcut menu, or • selecting the symbol to be labelled in the Engineering Explorer, then selecting

Properties from the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

12.18:76© 2011 AVEVA Solutions Ltd

Page 465: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. If either for the first two methods of starting the procedure is followed, the AVEVA P&IDEquipment Properties dialog for the symbol is then displayed (see below).

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the item to be labelled, or to edit an existing label, pick the item label.

To edit an existing trim label, pick the trim label and continue as described below for the AVEVA P&ID Pipeline Properties dialog.

3. The AVEVA P&ID Equipment Properties dialog is then displayed (see 4.8: Properties Dialogs):

Note: The number field may be completed automatically. See 6.10.25: Automatic Tagging. Automatically entered number fields may be manually overwritten if required.

Enter the equipment label details and click on the OK button. 4. The Command prompt will display:

Position Equipment Label:

Place the label near the equipment item. If a symbol, such as a box, is set to be placed with the label, it is inserted automatically at the same time as the label.

12.18:77© 2011 AVEVA Solutions Ltd

Page 466: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Note: If fixed equipment label formatting is off, the components of the label will be placed at the coordinates from the insertion point specified using the AVEVA P&ID Project Administration program.

5. If fixed label formatting is toggled from on to off, or visa versa, the positions of equipment label components will automatically change to reflect this the next time the drawing is opened.

Even if fixed label formatting is off, only the settings of the XEQ (equipment letter) label type, text height, rotation and so on, are taken into account.

6. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another equipment item to continue labelling, or press or select Enter to end the command.

• Adding a Trim Label 1. If the equipment is a vessel, a trim label may also be added. Select Add Trim Label

from The Drawing Page shortcut menu for the vessel.

The AVEVA P&ID Trim Pipe Properties dialog is displayed (see 4.8: Properties Dialogs):

12.18:78© 2011 AVEVA Solutions Ltd

Page 467: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Enter details in the Fluid Service, Number, Specification and other fields that are available according to the project line tag setup. These values are subsequently applied to any trim pipework labelled at a later stage. A size entry cannot be made at this stage. When entries are completed, click on the OK button.

2. The Command prompt will display:

Position Trim Label:

Place the label as required.

8.6.4 Labelling Electrical Equipment

• Description The procedure can be used to label Electrical Equipment.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.5: Labelling Equipment.

• Example

12.18:79© 2011 AVEVA Solutions Ltd

Page 468: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration Options • If equipment data is to be imported from VPE Workbench, by use of the EDL item type,

the Import Equipment Data checkbox in the Equipment Data from VPE Workbenchsection of the Equipment - Settings Sub-Set must be checked. The placing of the imported data information is specified by the Column 'X' and Row 'Y' Offsets fields in this section.

• The number of equipment label fields, 4 or 6, is specified in the Number Of TAG fields section of the Equipment - Settings Sub-Set.

• The boilerplate text to replace the defaults of Block, Function, Prefix, Tag, Number and Suffix in the Equipment properties dialog is specified in the Dialog Box Field labels section of the Equipment - Settings Sub-Set.

• To set the last value entered in a Properties dialog field to automatically populate that field that next time that Properties dialog is accessed for an unlabelled item of that item type, use the checkboxes in the Values to Remember from Last Equipment Edit section of the Equipment - Settings Sub-Set.

• Inheritance between equipment label and sheet attribute fields, and whether or not inherited values are displayed on P&IDs, is set up using the Equipment - Settings Sub-Set.

• The project may be set to check that equipment labels in all P&IDs in the project are unique using the Label Validation across P&IDs section of the Equipment - Settings Sub-Set.

• Whether or not delimiters are required after fields in an equipment label is specified in the Label Format section of the Equipment - Labels Sub-Set. The delimiters to be used are chosen in the same section.

• Whether or not fixed equipment label formatting is in use, and the coordinates of label components if it is not, are specified in the Equipment Label Position section of the Equipment - Labels Sub-Set.

• The display order of fields in equipment labels is specified in the Equipment Label Format section of the Equipment - Labels Sub-Set.

• Equipment labels may automatically have a symbol placed with them when they are inserted. For example, they may be placed in a box. This functionality is switched on and off, the required symbol selected, and the offset from the label specified using the Equipment Label Symbol section of the Equipment - Labels Sub-Set.

• Automatic tagging of equipment number fields (see 6.10.25: Automatic Tagging) is switched on and formatted on the Equipment - Automatic Tag Format Sub-Set.

• If it is required that the design area is used as the prefix for the equipment, the Design area from Title Block used for Instrument Label Field 1 checkbox has been checked in the Drawing - Labels Sub-Set.

• Instructions 1. The procedure may start automatically if auto-labelling for equipment is on. If this is the

case, the AVEVA P&ID Equipment Properties dialog displays automatically when the equipment is placed on the drawing.

• If auto-labelling is not on, or to edit an existing label, start the procedure by either: • selecting the symbol to be labelled on The Drawing Page, then selecting

Properties from the shortcut menu, or • selecting the symbol to be labelled in the Engineering Explorer, then selecting

Properties from the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however,

12.18:80© 2011 AVEVA Solutions Ltd

Page 469: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If either for the first two methods of starting the procedure is followed, the AVEVA P&IDEquipment Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the item to be labelled, or to edit an existing label, pick the item label. 3. The AVEVA P&ID Equipment Properties dialog is then displayed (see 4.8: Properties

Dialogs):

Note: The number field may be completed automatically. See 6.10.25: Automatic Tagging. Automatically entered number fields may be manually overwritten if required.

Enter the equipment label details and click on the OK button. 4. The Command prompt will display:

Position Equipment Label:

Place the label near the equipment item. 5. The Command prompt will display:

12.18:81© 2011 AVEVA Solutions Ltd

Page 470: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Select Item to Label, or Label to Modify:

Pick another electrical equipment item to continue labelling, or press or select Enter to end the command.

8.6.5 Adding Equipment Headers

• DescriptionThe procedure can be used to add headers to equipment. Headers include equipment labels plus any other required text as entered by the user. If an equipment label is changed, the equipment label in an equipment header is automatically updated.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.5: Labelling Equipment.

• Example

• Associated Project Configuration OptionWhether or not equipment headers are to be underlined on P&IDs is specified on the Equipment - Settings Sub-Set of the AVEVA P&ID Project Administration program.

12.18:82© 2011 AVEVA Solutions Ltd

Page 471: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by selecting Add Header from The Drawing Page shortcut menu

for the equipment.

2. Command prompt will display:

Insert Equipment Label Header:

Place the header near the equipment item. The command ends automatically.

Add any other equipment header text using standard AutoCAD facilities.

8.6.6 Labelling Nozzles

• Description The procedure can be used to label Nozzles.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.16: Labelling Nozzles

12.18:83© 2011 AVEVA Solutions Ltd

Page 472: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Errors An error message will be received if duplicate labels are placed.

• Associated Project Configuration Options • If unlabelled nozzles are to result in a warning being displayed during validation and/or

export, the Nozzle Error-Balloon Placement checkbox on the Label Types Configuration Category must be checked.

• If nozzle sizes are to cascaded onto connecting pipes, check the Cascade Nozzle to Pipe checkbox on the Nozzles - Settings Sub-Set .

• If nozzles are to be labelled using an automatically incrementing number, check the Increment Nozzle Sequence checkbox on the Nozzles - Labels Sub-Set.

• If nozzles labels are to automatically include a prefix, enter this prefix in the Nozzle Prefix field on the Nozzles - Labels Sub-Set.

• To set the last value entered in a Properties dialog field to automatically populate that field that next time that Properties dialog is accessed for an unlabelled item of that item type, use the checkboxes in the Values to Remember from Last Nozzle Edit section of the Miscellaneous - Settings Sub-Set.

• Instructions 1. The procedure may start automatically if auto-labelling for nozzles is on. If this is the

case, the AVEVA P&ID Nozzle Properties dialog displays automatically when a nozzle is placed on the drawing.

12.18:84© 2011 AVEVA Solutions Ltd

Page 473: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If auto-labelling is not on, or to edit an existing label, start the procedure by either: • selecting the symbol to be labelled on The Drawing Page, then selecting

Properties from the shortcut menu, or • selecting the symbol to be labelled in the Engineering Explorer, then selecting

Properties from the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If either for the first two methods of starting the procedure is followed, the AVEVA P&IDNozzle Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the nozzle. 3. The AVEVA P&ID Nozzle Properties dialog for the object is then displayed (see 4.8:

Properties Dialogs):

Enter the nozzle tag and, if required, a nozzle size.

Click on the OK button.

12.18:85© 2011 AVEVA Solutions Ltd

Page 474: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. The Command prompt will display:

Position Nozzle Tag:

Place the nozzle tag.

The nozzle currently being labelled is highlighted. 5. The Command prompt will display:

Position Nozzle Size:

Place the nozzle size, if applicable. 6. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another nozzle to continue labelling, or press or select Enter to end the command.

8.6.7 Labelling General Valves

• Description The procedure can be used to label (non-Instrument) Valves, includng reducing valves. Pattern labels can be entered.

For details of labelling Instrument Valves see 8.6.12: Labelling General Instruments.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.6: Labelling General Valves.

• Example

12.18:86© 2011 AVEVA Solutions Ltd

Page 475: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration Options • If the valve tag is to be positioned on the drawing by the program, check the Valve Tag

in Fixed Location checkbox on the Valves - Settings Sub-Set of the AVEVA P&IDProject Administration program. Specify the position in which automatic placement takes place by entering coordinates in the Valve Tag Offset from Symbol Location fields.

• If valve tag labels are to be automatically rotated to match the orientation of the valves they are associated with, check the Rotate Valve Tag with Symbol checkbox on the Valves - Settings Sub-Set.

• Inheritance between valve label and sheet attribute fields, and whether or not inherited values are displayed on P&IDs, is set up using the Valves - Settings Sub-Set.

• If the validated valve code field is to be enabled by default in the Label Valve dialog/list box, the Use Valve code checkbox must be checked.

• The boilerplate text to replace the defaults of Prefix, Tag, Number and Suffix in the Valve Properties dialog is also specified on this pane.

• The project may be set to check that valve labels in all P&IDs in the project are unique using the Label Validation across P&IDs section of the Valves - Settings Sub-Set.

• If the valve code is to be positioned on the drawing by the user, check the Manual Placement checkbox on the Valves - Labels Sub-Set. If the code is to be placed automatically, specify the position in which automatic placement takes place by entering coordinates in the Code Offset from Symbol Origin fields.

• If the default setting of the Place Port Size fields on Properties dialogs for Port Valves is that port sizes should be placed, the Place Port Sizes checkbox must be checked.

• Valve labels may automatically have a symbol placed with them when they are inserted. For example, they may be placed in a box. This functionality is switched on and off, the required symbol selected, and the offset from the label specified using the Valve Label Symbol section of the Valves - Labels Sub-Set.

• If unlabelled ports on port valves are to result in a warning being displayed during validation and/or export, the Port Error-Balloon Placement checkbox on Label Types Configuration Category must be checked.

• The boilerplate text to replace the defaults of Prefix, Tag, Number and Suffix for SPP labels is specified on the Miscellaneous - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• Automatic valve tagging (see 6.10.25: Automatic Tagging) is switched on, and the format of automatic valve tags defined on the Valves - Automatic Tag Format Sub-Set.

• Patterns are defined using the Valves – Patterns Sub-Set.

• Inheriting Label Data from the Owning Pipe Label Valve tag data may be inherited from the label of the owning pipe, as set-up on the Valves - Settings Sub-Set of the AVEVA P&ID Project Administration program. For details of setting up the inheritance, see 8.6.31: Setting Symbols to Inherit Label Data from a Manually Selected Pipe.

If a valve has the inherited values in its label edited using the procedure below, this will cancel the inheritance.

• Instructions 1. The procedure may start automatically if auto-labelling for valves is on. If this is the

case, the AVEVA P&ID Valve Properties dialog displays automatically when a valve is placed on the drawing.

If auto-labelling is not on, or to edit an existing label, start the procedure by either:

12.18:87© 2011 AVEVA Solutions Ltd

Page 476: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• selecting the symbol to be labelled on The Drawing Page, then selecting Properties from the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Valve Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the general valve to be labelled, or to edit an existing label, pick the item label.

12.18:88© 2011 AVEVA Solutions Ltd

Page 477: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Valve Properties dialog is then displayed (see 4.8: Properties Dialogs):

Enter the tag and any SPP labelling.

Note: The valve tag may be completed automatically. See 6.10.25: Automatic Tagging. Automatically entered valve tags may be manually overwritten if required. If the number of automatically tagged valves on a drawing exceeds the range of numbers defined for it, an error message is displayed, and the tag will placed without an incremented number.

Enter size, closure and code details as dictated by the project configuration options, and specify text angles as required.

4. If the valve is to be a substitute, select the pattern reference from the Pattern Reference list.

5. If the valve is a reducing valve, select Yes from the Is Reducing Valve field. Otherwise leave set to No.

12.18:89© 2011 AVEVA Solutions Ltd

Page 478: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The Upstream Size and Downstream Size fields display the current upstream and downstream pipe sizes. When the Is Reducing Valve field is set to Yes, these values may be edited. Pipe and reducer labels and properties upstream and downstream of the valve location will have their sizes automatically modified to reflect these size changes.

6. If the valve is a port valve, the valve ports may also need to be labelled. See 8.6.8: Labelling Port Valves.

Click on the OK button. 7. The Command prompt will display:

Position Valve Tag:

Place the tag. 8. If applicable, the Command prompt will display:

Position Valve Closure:

Place the closure. 9. If applicable, the Command prompt will display:

Position Special Item Label Prefix:

Place the SPP prefix. 10. If applicable, the Command prompt will display:

Position Special Item Label Type:

Place the SPP label type. 11. If applicable, the Command prompt will display:

Position Special Item Label Number:

Place the SPP label number. 12. If applicable, the Command prompt will display:

Position Special Item Label Suffix:

Place the SPP label number.

12.18:90© 2011 AVEVA Solutions Ltd

Page 479: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

13. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another valve to continue labelling, or press or select Enter to end the command.

8.6.8 Labelling Port Valves

• Description The procedure can be used to label Port Valves.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.9: Labelling Port Valves.

• Example

• Associated Project Configuration Options • If the default setting of the Place Port Size fields on Port Valves Properties dialogs is to

be "True" (port sizes to be placed), the Place Port Sizes checkbox on the Valves - Labels Sub-Set must be checked.

• If unlabelled ports on port valves are to result in a warning being displayed during validation and/or export, the Port Error-Balloon Placement checkbox on Label Types Configuration Category must be checked.

12.18:91© 2011 AVEVA Solutions Ltd

Page 480: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. To label a port valve, proceed as described in the Labelling Valves procedure until the

AVEVA P&ID Valve Properties dialog is displayed and complete the standard fields (see 4.8: Properties Dialogs). In addition to these standard fields, the Properties dialog for a port valve includes a number of extra fields:

Assuming the display of ports is switched on (see 8.3.4: Turning the Display of Ports On and Off), the port currently being labelled is highlighted in a different colour on the drawing:

2. For each port, enter the name and a size. On the All Properties tab, specify whether or not this size will be displayed on the drawing (default setting is "No"). If the size is to be

12.18:92© 2011 AVEVA Solutions Ltd

Page 481: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

displayed, specify the drawing layer, angle, justification, height and width factor of the size text.

Note: If a port is connected to another item (pipe, reducer etc), the size of the port will automatically be derived from this once the drawing is validated and cannot be changed using the Properties dialog.

3. Once the Properties dialog has been completed, click on the OK button.

You will then be prompted to place the valve label data onto the drawing as described in the 8.6.7: Labelling General Valves procedure. If you specified that port size data should be placed, you will also be prompted to select the insertion points for each port label that were set to be displayed.

8.6.9 Labelling Inline Fittings

• Description The procedure can be used to label Inline Fittings (including Special Piping Items).

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.7: Labelling Inline Fittings (Special Piping Items).

• Example

• Associated Project Configuration Options • The boilerplate text to replace the defaults of Prefix, Tag, Number and Suffix in the Line

Fitting Properties dialog box is specified on the Miscellaneous - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• Line fitting labels may automatically have a symbol placed with them when they are inserted. For example, they may be placed in a box. This functionality is switched on and off, the required symbol selected, and the offset from the label specified using the Line Fittings Symbol section of the Line Fittings Configuration Category.

• The coordinates of Line Fitting label components relative to the insertion point of the symbol are specified in the Line Fittings Label Position section of the Line Fittings Configuration Category.

12.18:93© 2011 AVEVA Solutions Ltd

Page 482: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Inheritance between line fitting label and sheet attribute fields, and whether or not inherited values are displayed on P&IDs, is set up using the Line Fittings Configuration Category.

• The project may be set to check that special piping item line fitting labels in all P&IDs in the project are unique using the Label Validation across P&IDs section of the Line Fittings Configuration Category.

• Inheriting Label Data from the Owning Pipe Label Line fittings data may be inherited from the label of the owning pipe, as set-up on the Line Fittings Configuration Category of the AVEVA P&ID Project Administration program. For details of setting up the inheritance, see 8.6.31: Setting Symbols to Inherit Label Data from a Manually Selected Pipe.

If a line fittings has the inherited values in its label edited using the procedure below, this will cancel the inheritance.

• Instructions 1. Start the procedure by either:

• selecting the symbol to be labelled on The Drawing Page, then selecting Properties from the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Line Fitting Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the item to be labelled.

12.18:94© 2011 AVEVA Solutions Ltd

Page 483: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Line Fitting Properties dialog is then displayed (see 4.8: Properties Dialogs):

Enter the optional Prefix, Type, Number, and Suffix details.

Click on the OK button. 4. The Command prompt will display:

Position Special Item Label Prefix:

Place the label near the item. If a symbol, such as a box, is set to be placed with the label, it is inserted automatically at the same time as the label.

Note: If fixed inline equipment label formatting is off, the components of the label will be placed at the coordinates from the insertion point specified using the AVEVA P&IDProject Administration program.

Unlike equipment labels, if fixed label formatting is toggled from on to off, or visa versa, the positions of inline equipment label components will not automatically change to reflect this the next time the drawing is opened.

Place the SPP prefix, if applicable. 5. The Command prompt will display:

Select Item to Label, or Label to Modify:

12.18:95© 2011 AVEVA Solutions Ltd

Page 484: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pick another inline fitting to continue labelling, or press or select Enter to end the command.

8.6.10 Labelling Pipe Destination Fittings

• Description The procedure can be used to label pipe destination fittings.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.8: Labelling Pipe Destination Fittings.

• Instructions 1. Start the procedure by either:

• selecting the symbol to be labelled on The Drawing Page, then selecting Properties from the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Line Fittings Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the item to be labelled.

12.18:96© 2011 AVEVA Solutions Ltd

Page 485: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Line Fittings Properties dialog is then displayed (see 4.8: Properties Dialogs):

Enter the size, specification, Prefix, Type, Number and Suffix of the fitting as required.

Click on the OK button. 4. The Command prompt will display:

Position Label:

Place the label near or on the item. 5. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another item to continue labelling, or press or select Enter to end the command.

12.18:97© 2011 AVEVA Solutions Ltd

Page 486: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6.11 Creating Instrument Loops

• Description This procedure is used to create instrument loops.

Once an instrument loop has been created, instruments can be assigned to them.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.11: Labelling General Instruments.

• Associated Project Configuration Options The fields which are used to define the properties of instrument loops, and the loop fields from which instruments in a loop can inherit properties, are set using in Instrument Loop Tag section of the Instruments - Settings Sub-Set of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by right-clicking on the Instrument Loop node in the Engineering

Explorer.2. From the menu that is then displayed, select the New Loop option.3. The AVEVA P&ID Instrument Loop Properties dialog is then displayed (see 4.8:

Properties Dialogs).

12.18:98© 2011 AVEVA Solutions Ltd

Page 487: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. In the Type field, select the required instrument loop type.5. In the Loop field, enter the number of the loop.6. Depending on the project configuration settings, there may be other fields to complete,

i.e. Block, Function, Prefix and/or Suffix. Complete these as required.7. Click on the OK button. The new loop is then created is displayed under the Instrument

loop node in the Engineering Explorer.8. To assign an instrument to the new loop either:

• Select the loop number in the Instrument Loop Number field of the instrument's properties dialog (see 8.6.12: Labelling General Instruments), or

• In the Engineering Explorer, drag the instrument from the loop that it is currently in, and drop it onto the node of the new loop. Instruments that are not in a loop will be grouped under the UNNAMED node.

8.6.12 Labelling General Instruments

• Description The procedure can be used to label Instruments, flow elements, control valve balloons, and associated panels. Pattern labels can be entered.

When labelling flow elements, the balloons are labelled rather than the flow elements themselves. Labelling is then as for ordinary instruments, but no alarms are permitted.

When deleting data, the following rules should be noted: • Descriptors can be deleted individually, • Prefix, suffix and loop number are all deleted, regardless of which is picked for deletion, • If the type is deleted, the prefix, suffix and loop number are also deleted, • Alarms may be deleted individually.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.11: Labelling General Instruments, 6.10.12: Labelling General Instruments - Using Instrument Pattern Labels and 6.10.13: Labelling General Instruments - Panel Reference Labels.

• Example General Instruments

12.18:99© 2011 AVEVA Solutions Ltd

Page 488: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example Flow Elements

• Example Control Valves

• Associated Project File Configuration Options • The number of equipment label fields, 4 or 6, is specified in the Number of TAG fields

section of the Instruments - Settings Sub-Set of the AVEVA P&ID Project Administration program.

• The boilerplate text to replace the defaults of Block, Function, Prefix, Tag, Number and Suffix in the Instrument Balloon Properties dialog is specified in the Instrument Dialog Labels section on the Instruments - Settings Sub-Set must be checked.

• The boilerplate text to replace the defaults of Prefix, Tag, Number and Suffix in the Instrument Panel Reference dialog/list box is specified in the Instrument Panel Dialog Labels section of the same pane.

• Inheritance between instrument label and sheet attribute fields, and whether or not inherited values are displayed on P&IDs, is set up using the Instruments - Settings Sub-Set.

• Inheritance between instrument loops and the instruments that belong to them is set up on the Instruments - Settings Sub-Set.

• The project may be set to check that instrument labels in all P&IDs in the project are unique using the Label Validation across P&IDs section of the Instrument - Settings Sub-Set.

• If the instrument prefix, loop and suffix are imported from the external database, the Loop Numbers from VPE Workbench checkbox on the Instruments - Labels Sub-Set.

12.18:100© 2011 AVEVA Solutions Ltd

Page 489: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• If instrument prefixes are required for the project, ensure that the Prefix Label Required checkbox is checked.

• If labels are to be rotated when the symbol they are associated with is rotated, ensure that the Rotate Labels with Symbol checkbox is checked.

• The block name of the instrument label balloon symbols is specified in the Label Balloon Symbol field.

• The presence or absence of link lines is controlled by the Label Balloon Link-Lines Off checkbox.

• Fields in the Instrument Label Positions section govern the positions of the different elements that make up a label, relative to the insert point of the labelled instrument and instrument panel reference symbols.

• The project may be set to require that a selected field or a combination of fields in instrument labels be unique (in addition to the entire label being unique). The fields that are checked for uniqueness are selected in the Unique Tags section of the Instrument - Labels Sub-Set.

• Patterns are defined using the Instruments - Patterns Sub-Set. • Automatic tagging of instrument number fields (see 6.10.25: Automatic Tagging) is

switched on and formatted on the Instrument - Automatic Tag Format Sub-Set.• Whether or not instrument valves can appear as the source and destination of pipes,

and the list of instrument valves types that are to behave in this manner, is set using the Pipe Instrument Labelling checkbox and the Instruments Allowing Labelling fields on the Pipes - Labels Sub-Set.

• Inheriting Label Data from the Owning Pipe Label Instrument label data may be inherited from the label of the owning pipe, as set-up on the Instruments - Settings Sub-Set of the AVEVA P&ID Project Administration program. For details of setting up the inheritance, see 8.6.31: Setting Symbols to Inherit Label Data from a Manually Selected Pipe.

If an instrument has the inherited values in its label edited using the procedure below, this will cancel the inheritance.

• Instructions 1. The procedure may operate automatically if auto-labelling for instruments is on. If this

is the case, the AVEVA P&ID Instrument Balloon Properties dialog displays automatically when an instrument is placed on the drawing.

If auto-labelling is not on, or to edit an existing label, start the procedure by either: • selecting the symbol to be labelled on The Drawing Page, then selecting

Properties from the shortcut menu, or • selecting the symbol to be labelled in the Engineering Explorer, then selecting

Properties from the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If either for the first two methods of starting the procedure is followed, the AVEVA P&IDInstrument Properties dialog for the symbol is then displayed.

12.18:101© 2011 AVEVA Solutions Ltd

Page 490: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the instrument or instrument valve balloon to be labelled.

12.18:102© 2011 AVEVA Solutions Ltd

Page 491: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Instrument Properties dialog is then displayed (see 4.8: Properties Dialogs):

Note: The number field may be completed automatically. See 6.10.25: Automatic Tagging. Automatically entered number fields may be manually overwritten if required.

12.18:103© 2011 AVEVA Solutions Ltd

Page 492: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If a different balloon symbol is required, select it from the Balloon Symbol drop-down list.

Select the instrument type from the Type drop-down list.

Enter a prefix and loop number. 4. If a descriptor is required, enter its name in the Descriptor field. 5. If the instrument is to be a substitute, select the pattern reference from the Pattern

Reference list. 6. If the instrument is to be part of an instrument loop, select the loop number from the

Instrument Loop Number field. If the instrument is not to be part of an instrument loop, leave this field set to the default "UNNAMED" setting.

An instrument can also be assigned to a loop by dragging and dropping it into a loop in the Engineering Explorer.

Note: Loops are created using the Creating Instrument Loops procedure.

When an instrument is assigned to a loop, its Number field value is automatically overwritten by that of the loop. This cannot be changed. The Number field is disabled.

In the AVEVA P&ID Project Administration program, instruments can be set to inherit other values from the instrument loop they belong to: Block, Function, Prefix and/or Suffix. When an instrument is assigned to a loop, the values in fields that are inherited from the loop are automatically overwritten by those of the loop and cannot be changed.

7. If the instrument is a remote instrument, enter data for the four alarm labels (L, H, LL, HH, etc).

Click on the OK button. 8. If the instrument is a remote instrument, a prompt is displayed for entry of four alarm

labels (L, H, LL, HH, etc). Enter the alarm data and click on the OK button. 9. If the instrument is panel mounted, enter details of Prefix, Type, Loop and Suffix for the

panel that the instrument or instrument valve is mounted on, and select the panel type.

Click on the OK button. 10. The Command prompt will display:

Position Descriptor Label:

Place the label near the instrument. 11. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another instrument to continue labelling, or press or select Enter to end the command.

12.18:104© 2011 AVEVA Solutions Ltd

Page 493: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6.13 Labelling System I/O Connections, Interlocks and Logic Boxes

• Description The procedure can be used to label I/O connections, interlocks and logic boxes.

These labels can be deleted individually, without affecting other labels.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.14: Labelling System I/O Connections, Interlocks and Logic Boxes.

• Example

• Instructions 1. Start the procedure by either:

• selecting the symbol to be labelled on The Drawing Page, then selecting Properties from the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Instrument Accessory Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the item.

12.18:105© 2011 AVEVA Solutions Ltd

Page 494: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Instrument Accessory Properties dialog is then displayed (see 4.8: Properties Dialogs):

Enter the label for the item.

Click on the OK button. 4. The Command prompt will display:

Position Label:

Place the label near or on the item. 5. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another item to continue labelling, or press or select Enter to end the command.

12.18:106© 2011 AVEVA Solutions Ltd

Page 495: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6.14 Labelling I/O Rockets

• Description The procedure can be used to label an I/O rocket, or to associate a rocket with an instrument.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.15: Labelling I/O Rockets.

• Example

• Associated Project File Configuration Options • If I/O rocket labels are to be placed on the Non-plot layer, ensure that the Labels on

Non-Plot Layer checkbox on the Instruments - Labels Sub-Set of the AVEVA P&IDProject Administration program is checked.

• The X, Y offsets in the Offset from Symbol Origin fields control the automatic positioning of the I/O Address, Card Type, Signal Type and Remarks components of the labels.

• The four components of labels may be individually rotated as they are brought in from VPE Workbench. Check the appropriate Rotate with Symbol checkboxes to activate the rotation.

12.18:107© 2011 AVEVA Solutions Ltd

Page 496: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by either:

• selecting the symbol to be labelled on The Drawing Page, then selecting Properties from the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Instrument Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the I/O Rocket. 3. The Command prompt will display:

Select Instrument Item for Association, or <Enter> for Tag:

Either associate the rocket with an instrument (a) or enter a tag (b).

a. To associate the rocket with an instrument, pick the instrument and data point. The instrument and rocket are now associated and the procedure is complete for the rocket. (The association can be checked by using ASSHOW.)

12.18:108© 2011 AVEVA Solutions Ltd

Page 497: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

b. To enter a tag, press or select Enter. The AVEVA P&ID Instrument Properties dialog is then displayed (see 4.8: Properties Dialogs):

12.18:109© 2011 AVEVA Solutions Ltd

Page 498: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. Select the instrument type from the Type drop-down list.

Enter a prefix and loop number.

Descriptors cannot be entered.

If the rocket is to be a substitute, enter the Pattern Reference field.

Note: Pattern labels are case sensitive.

5. If the instrument is panel mounted, enter details of Prefix, Type, Loop and Suffix for the panel that the instrument is mounted on, and select the panel type

Click on the OK button. 6. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another rocket to continue labelling, or press or select Enter to end the command.

8.6.15 Labelling Revision Triangles

• Description The procedure can be used to label revision triangles.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.21: Labelling Revision Triangles

• Example

12.18:110© 2011 AVEVA Solutions Ltd

Page 499: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Errors Error messages will be received if duplicate revision numbers are placed, or if the revision number, the identity of the reviser or the description of the revision are not entered.

• Instructions 1. Start the procedure by either:

• selecting the symbol to be labelled on The Drawing Page, then selecting Properties from the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Revision Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the revision triangle to be labelled.

12.18:111© 2011 AVEVA Solutions Ltd

Page 500: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Revision Properties dialog is then displayed (see 4.8: Properties Dialogs):

Enter details in the following fields: • Project - Project number • Number - Unique revision number or letter • Revised - Initials of the person involved • Line 1, Line 2 and Line 3 - information about the revision. • Checked - Initials of the person responsible for checking the revision. • Approved - Initials of the person responsible for approving the revision. • Date - Date of final approval.

Click the OK button. 4. The Command prompt will display:

Position project code:

Place the project code in the appropriate position on the drawing.

12.18:112© 2011 AVEVA Solutions Ltd

Page 501: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

5. The Command prompt will display:

Position revision number:

Place the revision number in the appropriate position on the drawing. The revision number is automatically placed inside the revision triangle.

6. The Command prompt will display:

Position revised code:

Place the initials of the person making the change in the appropriate position on the drawing.

7. The Command prompt will display:

Position description line 1 (or 2) (or 3):

Place the particular line of the 'description and comment' in the appropriate position on the drawing.

8. The Command prompt will display:

Position checked code:

Place the initials of the person checking the revision in the appropriate position on the drawing.

9. The Command prompt will display:

Position approved code:

Place the initials of the person approving the revision in the appropriate position on the drawing.

10. The Command prompt will display:

Position revision date:

Place the date of final approval in the appropriate position on the drawing.11. The Command prompt will display:

Position revision number:

12.18:113© 2011 AVEVA Solutions Ltd

Page 502: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Place the revision number with the grid reference, if used.12. The Command prompt will display:

Position grid reference:

Place the grid reference, if used.13. The Command prompt will display:

Select Item to Label, or Label to Modify:

Select another revision triangle to label, or press or select Enter to end the command.

8.6.16 Creating Pipe Groups

• Description This procedure is used to create pipe groups.

Once a pipe group has been created, pipes can be assigned to them.

For details of the use of this procedure in the context of drawing P&IDs, see 6.11.3: Labelling Pipes.

• Associated Project Configuration Options The pipe groups that may be created are specified in a DataSet which is defined using the User Defined Attributes - DataSet Sub-Set of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by right-clicking on the Pipes node or an existing pipe group node

in the Engineering Explorer.2. From the menu that is then displayed, select the New Group option.3. The AVEVA P&ID Group Properties dialog is then displayed (see 4.8: Properties

Dialogs).

12.18:114© 2011 AVEVA Solutions Ltd

Page 503: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. In the Group Name field, select the required group name. The list is restricted to the attribute names specified in the pipe group DataSet.

5. In the Value field, enter the user-defined attribute values associated with the group. A default value may have been specified for the group in the DataSet definition. This may be changed is required.

6. Click on the OK button. The new group is then created is displayed under the Pipes node in the Engineering Explorer, beneath the list of pipes.

7. To assign a pipe to the new group drag and drop it from the list of pipes onto the group node in the Engineering Explorer.

The Properties dialog of the pipe will then displays the group to which it is assigned. For example:

12.18:115© 2011 AVEVA Solutions Ltd

Page 504: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Remove a pipe from a pipe group by dragging it from the pipe group node onto the Pipes node, or onto another pipe group node.

8. To delete a pipe group, right-click on it and select Delete from the menu that is then displayed. The group is then deleted. Pipes in the group are not deleted and are returned to the list of pipes under the Pipes node.

8.6.17 Labelling Pipes

• Description The procedure can be used to create and edit pipe labels. A pipe can have multiple labels. Each segment of a pipe may be labelled, and pipe labels can be placed on either side of reducers and breaks as required.

Note that pipes and identified as main, branch or trim pipes when they are inserted. The procedure for labelling all types of pipe is the same

For details of the use of this procedure in the context of drawing P&IDs, see 6.11.3: Labelling Pipes.

• Examples Pipe with multiple labels:

12.18:116© 2011 AVEVA Solutions Ltd

Page 505: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pipe with branch:

• Associated Project Configuration Options • To set the last value entered in a Properties dialog field to automatically populate that

field that next time that Properties dialog is accessed for an unlabelled item of that item type, use the checkboxes in the Values to Remember from Last Pipe Edit section of the Pipes - Settings Sub-Set of the AVEVA P&ID Project Administration program.

• Inheritance between pipe label and sheet attribute fields is set up using the Pipes - Settings Sub-Set.

• The project may be set to check that pipe labels in all P&IDs in the project areunique using the Label Validation across P&IDs section of the Pipes - Settings Sub-Set.

• If required, the cascading to branches of changes to properties of the main pipe can be disabled for specified properties using facilities in the Cascade Settings section of the Pipes - Settings Sub-Set.

• The format of pipe labels, i.e., the components of the labels and the order in which they are placed, are defined in the Pipe Label Format section of the Pipes - Labels Sub-Set.

• The Fixed Pipe Label Format checkbox determines whether or not fixed (also known as standard) labelling formatting is the default setting.

• The format in which pipe labels are displayed on a drawing, which may differ from the actual format, is defined in the Display Label Format section of the Pipes - Labels Sub-Set.

• The display format of source and destination labels where the source/destination is a different pipe may be different from the normal display format. If required, this facility is switched on an defined in the Source and Destination Formats section of the Pipes – Labels Sub-Set.

• The delimiter is specified in the Delimiter field. If a delimiter is required after an area code, ensure that the Delimiter After Area Field checkbox is checked. If a delimiter is not required, the program needs to know how many characters are allowed for the Area field. Enter this in the Number of Characters field.

12.18:117© 2011 AVEVA Solutions Ltd

Page 506: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• The project may be set to require that a selected field or a combination of fields in instrument labels be unique (in addition to the entire label being unique). The fields that are checked for uniqueness are selected in the Unique Validation field of the Instruments - Labels Sub-Set.

• Use the Trim Label Prefix field to specify the text prefix to the trim identifier in a trim label.

• The names of the 3 project defined fields that may be part of pipe labels are established in the Project Definable Fields section.

• If split labelling is required, use the Split After Field field in the Split Format section to indicate which field in the pipe format to split on. The 'Y' Offset Above Line and 'Y' Offset Below Line fields are used to specify the distance that the 2 parts of label are placed above and below the line.

• Whether or not instrument valves can appear as the source and destination of pipes, and the list of instrument valves types that are to behave in this manner, is set using the Pipe Instrument Labelling checkbox and the Instruments Allowing Labelling fields in the Display Instrument Labels at Pipe Destination section.

• Pipe labels in fixed label format may automatically have a symbol placed with them when they are inserted. For example, they may be placed in a flag symbol or box. This functionality is switched on and off, the required symbol selected, and the offset from the label specified using the Pipe Label Symbol section.

• If split label formatting is to be used and a pipe label symbol is to be used, up to four label fields may be positioned before the split in the selected label symbol, as defined in the Define Split labels and offset for symbol section.

• The distance of single pipe labels from pipe segments may optionally be specified in the Fix Single Pipe Label from owner segment section.

• If a user may specify which of a pipe's labels is the default label, which will be used to identify it in the database, this facility is switched on in the Default Reporting Label Format section. The colour used to highlight such labels on drawings is also set in this section.

• Automatic tagging of pipe number fields (see 6.10.25: Automatic Tagging) is switched on and formatted on the Equipment - Automatic Tag Format Sub-Set.

• Nozzle sizes may automatically be cascaded onto connected pipes, depending on the setting of the Cascade Nozzle to Pipe checkbox on the Nozzles - Settings Sub-Set .

• Instructions• Labelling an Unlabelled Pipe• Adding Extra Labels to a Labelled Pipe• Setting a Pipe Label as the Default Pipe Label

- Labelling an Unlabelled Pipe

1. The procedure may operate automatically if auto-labelling for pipes is on. If this is the case, pipes nodes are placed and the AVEVA P&ID Pipeline Properties dialog displays automatically when the pipe is drawn (see below).

If auto-labelling is not on start the procedure by either: • selecting the pipe to be labelled on The Drawing Page, then selecting Properties

from the shortcut menu, or • selecting the pipe to be labelled in the Engineering Explorer, then selecting

Properties from the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

12.18:118© 2011 AVEVA Solutions Ltd

Page 507: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If either for the first two methods is followed, the pipe is already selected.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the pipe. 3. The AVEVA P&ID Pipe Properties dialog is then displayed (see 4.8: Properties

Dialogs):

Complete the entry fields with the required pipe label data.

Note: The number field may be completed automatically. See 6.10.25: Automatic Tagging. Automatically entered number fields may be manually overwritten if required.

12.18:119© 2011 AVEVA Solutions Ltd

Page 508: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Select the style of pipe, i.e. its appearance, in the Pipe Style field, or leave it set to the default style. The default pipe style is set using facilities in the Pipeline Group of the Home Tab.

Note: A Process Link pipe style is available. Pipes drawn using this method will look like Process Links but will functionally be Pipes.

Note: Valve and reducer symbols may be restricted so that they can only be inserted into pipes with specific spec codes and sizes. This is setup using the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program. When the spec or size of a pipe is changed, the system checks whether or not the symbols inserted into the pipe would still be valid for the new spec code or size of the pipe. If any would not be valid, the change may be prevented, or a warning displayed, depending on the project setup.

Note: Pipes may be added to a pipe group, created for reporting purposes. If a pipe has been added to a group, details of the group are also displayed in the dialog. They may not be edited. See 8.6.16: Creating Pipe Groups for further details.

4. If the pipe label is to be displayed on the drawing, select Yes in the Add Label field (this is the default setting). If the label is not to be displayed select No. This field is not displayed when editing a pipe that already has a label displayed

5. The Command prompt will then display:

Position pipe label:

Pick a point for the pipe label. If a symbol, such as a box, is set to be placed with the label, it is inserted automatically at the same time as the label.

If the split pipe labelling is being used, splitting of the label occurs when the label is placed on top of the pipe.

If the Fix pipe label position for single labels setting is in used, the pipe labels will automatically be placed the specified distance from the owning segment, on the side of the segment that the user clicks on.

- Adding Extra Labels to a Labelled Pipe

1. Use this procedure to add labels to a pipe that has already been labelled, e.g. to unlabelled segments of such a pipe.

Start the procedure by either:• right-clicking on the label of the pipe and selecting the Add Label option from the

shortcut menu, or• selecting the pipe to add a label to and selecting the Add Label option in Properties

Group of the Home Tab.2. If the first method of starting the procedure is followed, the following menu is then

displayed:

12.18:120© 2011 AVEVA Solutions Ltd

Page 509: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the segment is to be labelled with the entire label of the pipe, select the Full option. If the segment is to be labelled with only a single property of the pipe, select that properties, e.g. Size, from the menu.

Click on OK. 3. If the second method is selected, the following dialog is displayed:

If the segment is to be labelled with a full pipe label, in the default Display Label Format specified in the project configuration, select the Full Label option from the top list.

If the segment is to be labelled with only a single property of the pipe, select the Single Label option from the top list, and the property, e.g. Size, from the list below it.

12.18:121© 2011 AVEVA Solutions Ltd

Page 510: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the segment is to be labelled with a different Display Label Format from the default, select Custom Label from the top list, then select the required format from table beneath the lists.

Click on the Add Label & Close button to add the label and finish the procedure. Click on the Add Label button if further labels are to be added to the pipe using the dialog.

4. The Command prompt will then display:

Position pipe label:

Pick a point for the pipe label. The label is then placed.

If the Add Label & Close button was selected, the command then ends. If the Add Label button was selected, the above dialog is displayed again. Add further labels as described above.

- Setting a Pipe Label as the Default Pipe Label

A pipe may be labelled with labels in various formats. Depending on the project configuration, one of these labels may be set as the default label, i.e. the label that will be used to identify the pipe in the database.

To set a pipe label to be the default pipe label, right-click on the pipe label on the drawing page, then select Set as Default Label from the shortcut menu.

Depending on the project configuration, the selected label may then be displayed in a different colour.

8.6.18 Labelling and Connecting Pipe Flags

• Description The procedure can be used to label Pipe Flags (i.e. off-sheet or page connectors) and to establish connections between Pipe Flags. Pipe flag labels display the drawing that the connection is to, and optionally the grid reference of the connection (another pipe flag) on that drawing.

This topic also describes how to propagate changes made to the properties of pipes from one drawing to another via connected pipe flags, and how to disconnect pipe flags.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.20: Labelling Pipe Flags .

Note: Details of a connector can be viewed by hovering the cursor over the connector flag. Details are displayed on the tooltip. The STATUS: property indicates whether or not the connector is LINKED, in which the number of the connected drawing is also displayed, or UNLINKED.

12.18:122© 2011 AVEVA Solutions Ltd

Page 511: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the symbol is displayed, this indicates that the connector is hyperlinked. Ctrl-clicking on it, or selecting the Open Target Drawing option from the flag's right-click menu, will open the drawing on which connected pipe flag is located.

• Associated Project File Configuration OptionsSpecify the display format and position of pipe flag labels in the Offsheet Connector Configuration Category of the AVEVA P&ID Project Administration program.

• InstructionsPipe flags can be labelled, and connections to other pipe flags established using two procedures:

• Labelling and Connecting using the Page Connector Properties dialog• Labelling and Connecting using the P&ID Data Grid

Once pipes have been connected using pipe flags, changes made to the properties of pipes can be propagated to the properties of a connected pipes on other drawings:

• Propagating Changes to Pipe Properties

To disconnect pipe flags, use the following procedure:• Disconnecting Pipe Flags

- Labelling and Connecting using the Page Connector Properties dialog

1. Start the procedure by either: • selecting the symbol to be labelled on The Drawing Page, then selecting

Properties from the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Pipe Connector Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

12.18:123© 2011 AVEVA Solutions Ltd

Page 512: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pick the pipe flag to be labelled, or a pipe flag label to be modified.

12.18:124© 2011 AVEVA Solutions Ltd

Page 513: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Page Connector Properties dialog is then displayed (see 4.8: Properties Dialogs):

If connecting to a flag that has already been labelled, select the drawing number of the project drawing that the connected pipe flag is on.

Note that the list of available drawings is restricted to those of unconnected flags that match the properties and direction of the connection, i.e.:

• destination flags can only be connected to source flags, and vice versa, and • the connected pipe flag must share the same pipe properties.

Select the grid reference of the flag on that drawing. The list of available grid references is restricted to those of unconnected flags that match the drawing number and direction of the connection.

If connecting to a pipe flag that has not yet been drawn or labelled, enter a drawing number and grid reference as required.

If the flag is to be hyperlinked, i.e. Ctrl-clicking on it will open the drawing on which other end of the connector is located, select Yes from the Hyperlink field. Otherwise select No.

As required, enter additional information to label the flag in the Text fields.

12.18:125© 2011 AVEVA Solutions Ltd

Page 514: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Click on the OK button.

Note: When connections between pipe flags are made using the Properties sheet, in order for the link between two connected pipe flags to be established, the drawings that the two ends of the connection are on must both be synchronised (see 8.8.5: Synchronising Data with a VPE Workbench Database). This is not necessary when connections are made using the P&ID Data Grid.

4. The Command prompt will then display:

Position Pipe Flag Label:

Place the label centrally inside the pipe flag. 5. If any additional label text was entered in the Text fields, the Command prompt will then

display the following for each of the fields that was entered:

Insertion point or select escape key:

Place each piece of text as required. 6. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another pipe flag to continue labelling, or press or select Enter to end the command.

- Labelling and Connecting using the P&ID Data Grid

1. Start the procedure by right-clicking on an unassigned connector under the Unassigned Page Connectors node of the P&ID Data Grid, and select the Connect option from the menu that is then displayed.

12.18:126© 2011 AVEVA Solutions Ltd

Page 515: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The Off Page Reference dialog box is then displayed:

The Select Drawing Number field displays the current drawing number.2. To connect to a new pipe on the current drawing, select the New Pipe option. To

connect to an existing pipe, select the Existing option.3. If the connector symbol is to be hyperlinked, i.e. Ctrl-clicking on it will open the drawing

on which other end of the connector is located, check the Insert hyperlinks on symbol(s) checkboxes.

4. Press the OK button.5. If the New Pipe option is selected, the Drawing Pipes procedure (see 8.5.1: Drawing

Pipes) is automatically started. Draw and label the new pipe in the normal way. The pipe connector flag will automatically be linked to the selected unassigned connector, and labelled accordingly. The unassigned connector is removed from under the Unassigned Page Connectors node.

6. If the Existing option is selected the Command prompt will display:

Select Object:

Select a connector on the drawing. The label is placed in the flag symbol and the unassigned connector is removed from under the Unassigned Page Connectors node. The selected connector must match the properties and direction of the connection, i.e.:

• destination flags can only be connected to source flags, and vice versa, and• the connected pipe flag must share the same pipe properties.

If the selected connector does not meet these criteria, an error message is displayed, informing the user of this.

- Propagating Changes to Pipe Properties

To propagate changes made to the properties of a pipe to a pipe connected via a pipe flag, select the flag symbol on The Drawing Page, then selecting Propagate from the shortcut menu.

The pipe properties are then propagated to the other drawing, which is automatically opened.

12.18:127© 2011 AVEVA Solutions Ltd

Page 516: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the other drawing is already opened, or is otherwise unavailable for editing, and error message is displayed and the propagation does not take place.

- Disconnecting Pipe Flags

To disconnect a pipe flag select the flag symbol on The Drawing Page, then selecting Disconnect from the shortcut menu.

Note: If the properties of a pipe with a connected pipe flag are changed, and those changes are not propagated to the pipe flag on the other drawing, the pipe flags will automatically be disconnected the next time the drawings are synchronised.

8.6.19 Labelling Reducers

• Description The procedure can be used to label reducers.

For details of the use of this procedure in the context of drawing P&IDs, see 6.11.4: Labelling Pipes with Reducers and Reducing Valves.

• Example

• Associated Project Configuration Options • The orientation of reducer labels is specified using the Reducer Label Setting field on

the Pipes - Settings Sub-Set of the AVEVA P&ID Project Administration program. • If an error balloon is to be placed when a reducer is not labelled, ensure that the

"Reducer Not Labelled' Error-Balloon Placement checkbox on the Label Types Configuration Category of the AVEVA P&ID Project Administration program is checked.

• In order for reducers to automatically change orientation, so that the wide end is always connected to the larger pipe size and the narrow end is always connected to the smaller pipe size, the list of values for sizes used on the project (Metric Sizes or Imperial Sizes) set up using the List of Values Configuration Category must be sorted from smallest size to largest size.

• Instructions• Labelling a Reducer• Modifying a Reducer Label

- Labelling a Reducer

1. Start the procedure by either: • selecting the reducer on The Drawing Page, then selecting Properties from the

shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

12.18:128© 2011 AVEVA Solutions Ltd

Page 517: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the reducer is already selected.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the reducer symbol to be labelled.

12.18:129© 2011 AVEVA Solutions Ltd

Page 518: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Reducer Properties dialog is the displayed.

Both the Upstream Size and Downstream Size fields will pre-populated with the current size of the pipe segment into which the reducer was inserted.

Note that when upstream and downstream size values are the same, or are not valid for the pipe specification, the sizes and the tag preview are displayed in red text.

Change the upstream and/or downstream size to the required value(s). The lists of values for the sizes indicate which sizes are valid for the pipe specification. Invalid sizes, including those that would not form a valid combination with the other size, are displayed in red.

4. If the reducer label is to be displayed on the drawing, select Yes in the Add Label field (this is the default setting). If the label is not to be displayed select No. This field is not displayed when editing a reducer that already has a label displayed

Press OK.5. The Command prompt will then display:

Position Reducer Label:

12.18:130© 2011 AVEVA Solutions Ltd

Page 519: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Place the label. Pipe and reducer labels upstream and downstream of the reducer location will have their sizes automatically modified to reflect the sizes of the new reducer. If this results in another reducer having the same upstream and downstream sizes, an error message is displayed on the drawing, e.g.:

Note that the orientation of the label i.e. which diameter is listed first, is controlled by a project configuration setting (see above).

The orientation of a reducer symbol will change automatically so that the wide end is connected to the larger pipe size and the narrow end is connected to the smaller pipe size

6. If the end of the pipe is connected to the start of another pipe, the user is prompted to cascade the size change onto the connected pipe.

If the user chooses to do this, the process continues along the connected pipe changing sizes and warning users to change duplicate values as required.

- Modifying a Reducer Label

A reducer label can be modified by changing the size of the pipe label upstream. The upstream part of the next reducer label will automatically change to reflect this. Reducer labels may also be modified directly, as described below.

1. Start the procedure by either: • selecting the reducer label on The Drawing Page, then selecting Properties from

the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Reducer Properties dialog for the symbol is then displayed.

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the reducer label to be modified.

12.18:131© 2011 AVEVA Solutions Ltd

Page 520: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Reducer Properties dialog is displayed.

Select the required upstream and downstream sizes from the drop down lists and click OK.

The labels will change to show the new values.

Pipe and reducer labels upstream and downstream of the reducer location will have their sizes automatically modified to reflect the sizes of the new reducer. If this results in another reducer having the same upstream and downstream sizes, an error message is displayed on the drawing (see example above).

The orientation of a reducer symbol will change automatically so that the wide end is connected to the larger pipe size and the narrow end is connected to the smaller pipe size.

4. If the end of the pipe is connected to the start of another pipe, the user is prompted to cascade the size change onto the connected pipe.

If the user chooses to do this, the process continues along the connected pipe changing sizes and warning users to change duplicate values as required.

Note: If a reducer is deleted, the pipe segment that the reducer was inserted into adopts the size of the segment that was upstream of the deleted reducer.

12.18:132© 2011 AVEVA Solutions Ltd

Page 521: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6.20 Labelling Breaks and Inline Breaks

• DescriptionThe procedure can be used to label breaks (at the ends of pipes) and inline breaks (within a pipe run). The procedure labelling both types of break is the same.

For details of the use of this procedure in the context of drawing P&IDs, see 6.11.5: Labelling Pipes with Breaks and Inline Breaks.

• Example

• Instructions• Labelling Breaks• Editing Breaks

- Labelling Breaks

1. Start the procedure by either: • selecting the break label (not the symbol) on The Drawing Page, then selecting

Properties from the shortcut menu, or • selecting the Properties option in Properties Group of the Home Tab

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Spec Properties dialog for the symbol is then displayed (see below).

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

Pick the break symbol (not the label) to be modified.

12.18:133© 2011 AVEVA Solutions Ltd

Page 522: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Specification Break Properties dialog (see 4.8: Properties Dialogs) is displayed.

4. The Specification and Insulation fields will display the current properties of the pipe into which the break has been inserted. Change the upstream and/or downstream values as required. Press OK.

5. The Command Prompt will then display:

Position upstream label for Break:

Position the upstream value of the inline break, e.g. the upstream specification value.

12.18:134© 2011 AVEVA Solutions Ltd

Page 523: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

6. The Command Prompt will then display:

Position downstream label for Break:

Position the downstream value of the inline break. 7. If the inline break is a break of more than one property, e.g. of area as well as

specification, the user will first be prompted to place the upstream and downstream specification values of each of the properties that change at the break point.

The user will not be prompted to place labels for properties with the same upstream and downstream values.

The command then ends automatically.

- Editing Breaks

Break labels may be edited by editing the pipe labels on either side on the break. The appropriate break labels are then updated automatically. For example, updating the upstream pipe label will cause the upstream break label to be updated accordingly.

If a break is positioned between a pipe and an equipment nozzle, editing the trim label of that equipment will result in the break label being updated on the equipment side of the break.

Breaks can also be edited using the AVEVA P&ID Specification Break Properties dialog. See Labelling Breaks for how to access and use this dialog.

If, as a result of editing, the upstream and downstream values of a break are the same, an error message will be displayed.

8.6.21 Adding Pipe Destination Text

• Description This procedure can be used for creating and positioning Pipe Destination text at the start or end of pipes. The pipe must already be labelled before pipe destination text can be added.

The procedure is also use for editing existing pipe destination text.

Note: If a pipe node is labelled, when P&ID data is exported, the pipe node will be counted as the source/destination of the pipe, rather than any item that it might be connected to, unless that connected item is a pipe flag.

For details of the use of this procedure in the context of drawing P&IDs, see 6.11.6: Adding Pipe Destination Text.

12.18:135© 2011 AVEVA Solutions Ltd

Page 524: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Errors An error message is initiated by overlaying pipes or arrows at an insertion point.

• Instructions 1. Start the procedure by either:

• selecting the pipe node to be labelled on The Drawing Page, then selecting Properties from the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab.

Note: Labels can also be viewed using the Non-Modal Properties Dialog, but tags cannot be directly entered into this dialog. Other details can be entered or changed however, and the drawing labelled with them. See Labelling Using the Non-Modal Properties Dialog.

2. If the first method of starting the procedure is followed, the AVEVA P&ID Pipe Destination Text Properties dialog is then displayed (see below).

If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

For new text, pick the end or start node of the pipe. When editing existing text, pick the text.

Note: When attempting to place a pipe flag and pipe destination text at a node, move the node from the end of the pipe, place the destination text, and then carefully move the mode back into place. This action prevents display of an error message caused by overlaying pipes or arrows at an insertion point.

12.18:136© 2011 AVEVA Solutions Ltd

Page 525: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The AVEVA P&ID Pipe Destination Text Properties dialog is displayed (see 4.8: Properties Dialogs):

Enter or edit the three lines of text, and click on the OK button.

Note: If VPE Workbench is being used, restrict the text to 32 characters, including a return at the end of each line.

4. The Command prompt will display:

Position first line of text:

Place the first line of text. If lines 2 or 3 are completed, they are automatically placed relative to the first line.

5. The Command prompt will display:

Select Item to Label, or Label to Modify:

Pick another node for to label with destination text, or select Cancel or press Ctrl-C to end the command.

12.18:137© 2011 AVEVA Solutions Ltd

Page 526: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6.22 Labelling with Data from the P&ID Data Grid

• DescriptionThis procedure is used to label the drawing with the properties of items displayed in the P&ID Data Grid. AVEVA P&ID, AVEVA P&ID Reports, AVEVA Instrumentation and AVEVA Schematic Database data may be used.

Labels added from the P&ID Data Grid may be refreshed by the data currently displayed in the grid, i.e. if either the label has been edited or the data in the grid has changed. See Refreshing P&ID Data Grid Labels.

Labels added from the P&ID Data Grid may be edited as Non-AVEVA P&ID text. See 8.6.24: Editing Non-AVEVA P&ID Text.

For details of the use of this command in the context of drawing P&IDs, see 6.10: Labelling Symbols and 6.11: Labelling Pipes.

• Instructions• Labelling with P&ID Data Grid Data by Dragging and Dropping• Labelling with P&ID Data Grid Data by using the Insert Property menu option

- Labelling with P&ID Data Grid Data by Dragging and Dropping

1. Start the procedure by selecting the cell containing the data that is to be used to label the drawing in the P&ID Data Grid.

2. Drag the data from the grid onto the drawing. The Command prompt will then display:

Pick insertion point

Pick the required point on the drawing. The data will then be added to the drawing.

- Labelling with P&ID Data Grid Data by using the Insert Property menu option

Start the procedure by selecting the grid table from which data is to be inserted

Right-click on the grid and select Insert Property from the menu that is then displayed.

12.18:138© 2011 AVEVA Solutions Ltd

Page 527: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The Select designators to insert on drawing dialog is then displayed.

This displays a list of data designators that may be placed on the drawing, relevant to type of item in the selected grid. Use the + boxes to expand the entries on the list to display the values associated with the designators.

If the positions of designators relative to the insertion point and each other is to be fixed, check the Fix position of designators checkbox and enter the relative position in the X Offset and Y Offset fields.

The value in the X Offset field controls the horizontal distance between each designator and its value. The value in the Y-Offset field controls the vertical distance between each line of designators and values when multiple designators are selected for insertion.

By default, the Properties dialog only displays those designators that have values defined against them. In order to have the Properties dialog display all designators, check the Display All Designators checkbox. Designators without values display a placeholder in the value column, for example:

<INS Altitude value>

Where “INS” indicates the relevant entity type (in this example instrument) and “Altitude” is the designator name.

3. Select data to place on the drawing by checking the checkboxes adjacent to the designators and values or value placeholders. It is possible to add a value or value

12.18:139© 2011 AVEVA Solutions Ltd

Page 528: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

placeholder to a drawing without the associated designator, but a designator may not be placed without the associated value or value placeholder.

4. As required, select further items to label and repeat the process.

Click OK. 5. The Command prompt will then display:

Pick insertion point:

Pick the required point on the drawing for the first item of data that was selected in the dialog. The first designator will then be added to the drawing. Repeat for all selected designators and their values.

If the Fix position of designators checkbox was checked, all designators and values are added in one go, their positions determined by the values in the X Offset and Y Offset fields.

8.6.23 Refreshing P&ID Data Grid Labels

• DescriptionLabels added from the P&ID Data Grid may be refreshed by the data currently displayed in the grid, i.e. if either the label has been edited or the data in the grid has changed.

Labels added from the P&ID Data Grid may be edited as Non-AVEVA P&ID text. See 8.6.24: Editing Non-AVEVA P&ID Text.

For details of the use of this command in the context of drawing P&IDs, see 6.10: Labelling Symbols and 6.11: Labelling Pipes.

• Instructions Complete the procedure by either:

• clicking the button in the P&ID Data Grid, or • selecting the Refresh Grid option in P&ID Reports Group of the Data Management

Tab.

8.6.24 Editing Non-AVEVA P&ID Text

• Description Non-AVEVA P&ID text, i.e. text that was inserted using AutoCAD commands or labels inserted from the P&ID Data Grid, may be edited.

• Instructions 1. Start the procedure by either:

• selecting the text to be edited on The Drawing Page, then selecting Propertiesfrom the shortcut menu, or

• selecting the Properties option in Properties Group of the Home Tab

12.18:140© 2011 AVEVA Solutions Ltd

Page 529: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. If the first method of starting the procedure is followed, the editor dialog for the text is then displayed.

Edit the text and click on the OK button. 3. If the other method is followed, the Command prompt will display:

Select Item to Label, or Label to Modify:

4. Pick the appropriate text

A warning is given:

WARNING: 15 Editing Non-AVEVA P&ID Entity

5. The editor dialog box appears, with the selected text displayed.

Edit the text and click on the OK button. 6. Pick another piece of AutoCAD text to edit, or press Enter to end the command.

8.6.25 Labelling Typical Items

• Description The AVEVA P&ID Typical Items feature enables one item to be identified as having data that is typical of many items. The details of the items represented by the typical item are added to the label of the item on the P&ID, but do not appear on the P&ID. The following items can be made typical of many:

• Pipes• Off-Sheet Connectors (Pipe Flags) • Instruments • Equipment • SPP Items • Valve Items • Nozzles.

For further details, see 6.15: Typical Items.

12.18:141© 2011 AVEVA Solutions Ltd

Page 530: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration Options • The Typical Item feature can be turned on or off by the Typical Labelling checkbox on

the Miscellaneous - Labels Sub-Set of the AVEVA P&ID Project Administration program.

• The colours of typical items and labels are also specified on this tab.

• Instructions 1. Label the item that is to be made typical in the normal way. 2. For each item that can be made into a Typical Item, the shortcut menu includes a

Typicals option. This option is available if the Typical Item facility is enabled at project level, and if the item has been labelled with the minimum mandatory data for the item type. The option accesses a dialog box for the entry, deletion and modification of the typical data. For example:

Existing typical labels are displayed in order number sequence. 3. To create a typical label, click where it says Click here to add new typical.... The new

label is placed at the bottom of the list of existing typical labels, if there are any. 4. Enter the required details in the fields provided. 5. Validated fields are automatically completed with the value entered in the previous row.

Amend as required. 6. The Order field is complete automatically with the position of the label in the list of

typical labels. Order numbers are assigned in ascending order.

To change the position of a typical label in the order, select it, and move it up or down the order using the Up and Dn buttons.

7. To delete a label, select it and press the Delete key.

12.18:142© 2011 AVEVA Solutions Ltd

Page 531: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8. Press the OK button to accept the typical data. Alternatively, press the Cancel button to close the dialog box, losing all the currently entered data.

• Points to Note • For instruments, SPP Items, Valves and Off-Sheet Connectors the number of typical

data records must match the number of typical pipes. An inconsistency in the number of typical data records is considered an error, and no typical data is output for the pipe in question.

• Typical data must be unique on a drawing. • The uniqueness of Typical SPP Items is checked, provided that the Labels to be

Unique checkbox on the Miscellaneous - Labels Sub-Set of the AVEVA P&ID Project Administration program is checked.

• Branches of Typical pipes will automatically become Typical, with the same Typical data set as their owner pipe.

• If a Typical pipe is connected to the nozzle of an Equipment item then both the Nozzle and the Equipment must also be Typical.

• If a Typical pipe has an Off-Sheet Connection flag on either or both ends, the connection label must also be Typical.

• If a Typical pipe has Valves, inline or process connected Instruments then these must also be Typical.

• Inconsistencies in the number of Typical data records for the pipe and the number of associated Typical items and any associated drawings are considered as errors, and no Typical data is output for that pipe.

• If a pipe label of a Typical pipe is set as the "main pipe label" (see 8.6.27: Setting a Pipe Label as the Main Label), all of the items that it represents also have that label set to be the main label.

8.6.26 Replacing Tags with Tags in the Automatic Tag Format

• DescriptionIf the automatic tagging facility is in use, the Valve Tag field and the number fields of Pipes, Instruments and Equipment on the Properties Dialogs are automatically completed when an item is labelled.

Existing items that were not automatically tagged may be re-tagged with tags in the automatic tag format using this procedure.

Note that items that were automatically labelled and then manually changed are not re-labelled by this procedure.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.25: Automatic Tagging.

• Associated Project File Configuration Options• Automatic tagging is switched on, and the format of automatic valve tags defined using

the Pipes - Automatic Tag Format Sub-Set, Instruments - Automatic Tag Format Sub-Set, Equipment - Automatic Tag Format Sub-Set, Valves - Automatic Tag Format Sub-Set of the AVEVA P&ID Project Administration program.

12.18:143© 2011 AVEVA Solutions Ltd

Page 532: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• InstructionsComplete the procedure by selecting as appropriate the Assign Tags Pipes, Assign Tags Instruments, Assign Tags Equipment or Assign Tags Valves option in Symbol Group of the Home Tab.

For the type of item in question, all tags or tag components (i.e. number fields) that were not assigned automatically are then replaced with automatically generated tags. Tag labels on the drawing are changed automatically changed to reflect this.

Note: Items that were automatically labelled and then manually changed are not re-labelled by this procedure.

8.6.27 Setting a Pipe Label as the Main Label

• Description This procedure is used, in the case of pipes that have multiple labels, to set one of these labels as the "main pipe label". By default, the properties of the pipe at the start node are presented as the "main" properties of the pipe on export. This option sets the label of another part of the pipe, which may be more representative of the properties of the pipe as a whole, to be the "main" properties.

The main pipe label is displayed in a different colour on the P&ID, and the part of the pipe that has been labelled as the "main" pipe label is displayed at the top of the hierarchy of a pipe and its branches in the Engineering Explorer. If no main pipe label has been set, the pipe start node properties assume this position by default.

If a pipe label of a typical pipe is set as the main label, all of the items that it represents also have that label set to be the main label.

For details of the use of this procedure in the context of drawing P&IDs, see 6.11: Labelling Pipes.

12.18:144© 2011 AVEVA Solutions Ltd

Page 533: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example No pipe label set as "main":

The pipe node properties are regarded as main properties of the pipe, as shown in the Engineering Explorer:

A label has now been set as the main label. It is displayed in a different colour from the other pipe labels:

The properties of the main pipe label are now regarded as main properties of the pipe:

• Associated Project Configuration Options The colour of main pipe labels is set using the Main Pipe Label field on the Pipes - Labels Sub-Set of the AVEVA P&ID Project Administration program.

12.18:145© 2011 AVEVA Solutions Ltd

Page 534: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions Complete the procedure by selecting the pipe label on The Drawing Page, then selecting Set As Main from the shortcut menu.

To reset the properties of the pipe node to be main properties of the pipe, select the pipe node and then select Set As Main from the shortcut menu.

8.6.28 Changing the Association of a Pipe Label

• Description This procedure is used to change the pipe with which a pipe label is associated, i.e. so that it displays the properties of a different pipe.

For details of the use of this procedure in the context of drawing P&IDs, see 6.11: Labelling Pipes.

• Instructions1. Start the procedure by selecting the pipe label on the drawing page, then selecting

Associate from the shortcut menu.2. The Command Prompt will then display:

Select the pipe segment to associate the label:

Select the pipe with which the label is to be associated.3. The association of the pipe label then changes. The label will now display the

properties of the selected pipe instead of the properties of the pipe it was previously associated with.

The pipe label should then be moved manually so that it is correctly positioned near the selected pipe.

12.18:146© 2011 AVEVA Solutions Ltd

Page 535: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6.29 Adding Notes to Items

• Description This procedure is used to add notes to items that are displayed alongside them on the drawing.

A maximum of 132 characters can be used, which automatically adopt the colour of the item to which the note relates. They are included in the output files when an export is carried out. Notes cannot be added to clouds, as clouds are not part of the data output. Notes are edited by using the labelling procedure (see 8.6.1: Labelling - General Information), but notes should not be confused with labels.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

• Example

• Instructions 1. Start the procedure by selecting the Note option in Symbol Group of the Home Tab. 2. The Command prompt will display:

Indicate Item for note:

Select the item to attach the note to. The chosen item is highlighted.

12.18:147© 2011 AVEVA Solutions Ltd

Page 536: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The Command prompt will then display:

Position Note:

Enter the note text, either at the Command prompt or at the cursor on the drawing. Press Enter. The note is positioned.

4. The Command prompt will then display:

Indicate Item for Note:

Pick another item or press Ctrl-C or select Cancel to end the command.

8.6.30 Globally Editing Labels

• Description This procedure is used to globally edit of the labels of all items other than pipes.

Take care while carrying out this procedure as it is possible to change many labels with a single use.

The following label fields can be edited using this procedure:

Instruments, Equipment and Line Fittings: Prefix, Suffix, Type, Loop/Number

Valves: Tag, Closure, Code, SPP Prefix, Suffix, Type and Number

Nozzles: Number and Size

Off-Sheet Pipe Connectors: Item Label

For details of the use of this procedure in the context of drawing P&IDs, see 6.11: Labelling Pipes.

• Instructions 1. Start the procedure by either

• entering Ctrl+F on the keyboard, or • selecting the Find and Replace option in Modify Group of the Home Tab.

12.18:148© 2011 AVEVA Solutions Ltd

Page 537: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. The Find And Replace dialog will be displayed:

3. Enter the label field text to find in the Find What in Labels field. 4. Enter the text to replace it with in the Replace With field. 5. Check the Find whole words only and/or Match case checkboxes as required. 6. To restrict the Find and Replace to a category of item instead of all items, select the

required category from the Item Type Filter list:

The number of items in the drawing to be searched is then displayed to the right of the list.

7. Select the Find button.

12.18:149© 2011 AVEVA Solutions Ltd

Page 538: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Details of the first item label with fields that include text that match the search criteria are then displayed. If there are no such items, a message is displayed to inform the user of this.

Note: This facility searches only within label fields for matches. It does not search across fields within labels; therefore a match that consists of parts of different fields within a label will not be found.

The drawing will focus on and zoom in closer to the item in question.

The dialog displays the current label values, and what these values will be changed to if replaced by the text entered in the Replace with field.

8. To search for the next item that meets to search criteria without changing the current item label, select the Find Next button.

9. Select the Replace button to carry out the replacement for the current item only. Then select the Find Next button to search for the next item that meets the search criteria and repeat the procedure.

10. Select the Replace All button to carry out the replacement for all items that meet the search criteria.

11. Select the Close button to close the dialog.

12.18:150© 2011 AVEVA Solutions Ltd

Page 539: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

12. Changes to labels are validated. If it is detected that a change to a label would be invalid, e.g. if it would result in duplicate labels, or labels with invalid values, an error message is displayed, and the replacement does not take place.

8.6.31 Setting Symbols to Inherit Label Data from a Manually Selected Pipe

• Description This procedure is used to set an instrument, inline equipment item, valve or line fitting to inherit label data from a selected pipe.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.4: Label Inheritance from Owning Pipes.

• Associated Project Configuration Options Pipe label data inheritance is configured on the Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Line Fittings Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by selecting the Inherit Owner Pipe Data option in Symbol Group

of the Home Tab.2. The Command prompt will display:

Select Item:

Select the item (instrument, inline equipment item, valve or line fitting).

Note: Only one item may be selected at a time, in order to reduce the chance of the wrong owning pipe being assigned to multiple items.

3. The Command prompt will then display:

Indicate Owner Pipe Label:

Select the label of the pipe that the item is to inherit label data from. This pipe is subsequently identified as the owner of the selected item.

4. The command ends automatically.

12.18:151© 2011 AVEVA Solutions Ltd

Page 540: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.6.32 Switching off Label Data Inheritance from Pipes

• Description This procedure is used to turn off the inheritance of pipe label data for valves and instruments.

For details of the use of this procedure in the context of drawing P&IDs, see 6.10.4: Label Inheritance from Owning Pipes.

• Associated Project Configuration Options Pipe label data inheritance is configured on the Instruments - Settings Sub-Set, Equipment - Settings Sub-Set, Valves - Settings Sub-Set and Line Fittings Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by selecting the Remove Inherit Data option in Symbol Group of

the Home Tab. 2. Select the items you wish to remove the inheritance from and press Enter.

8.6.33 Labelling Items with UDAs

• DescriptionThis procedure is used to label items on a drawing with their User-Defined Attribute (UDA) values, including DataSet UDAs.

UDA values are entered on the Properties dialogs of items which have UDAs defined for them. When UDA values in Properties dialogs (see 4.8: Properties Dialogs) are changed, UDA labels on the drawing are automatically changed to reflect this.

For details of the use of this procedure in the context of drawing P&IDs, see 6.12: Adding User-Defined Attributes.

• Associated Project File Configuration OptionsUser Defined Attributes are set up using the User Defined Attributes - UDA List of Values Sub-Set and the User Defined Attributes - DataSet Sub-Set of the AVEVA P&ID Project Administration program.

• Instructions1. Start the procedure by selecting the Insert UDAs option in Symbol Group of the Home

Tab.2. The Command prompt will display:

Select objects:

Select the objects to which UDAs labels are to be added.

12.18:152© 2011 AVEVA Solutions Ltd

Page 541: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The User Defined Data dialog is then displayed:

This displays a list of UDA label designators and values for the selected item.

If the positions of label designators relative to the insertion point and each other is to be fixed, check the Fix position of designators checkbox and enter the relative position in the X Offset and Y Offset fields.

The value in the X Offset field controls the horizontal distance between each label designator and its value. The value in the Y-Offset field controls the vertical distance between each line of label designators and values when multiple labels are selected for insertion.

4. Select data to label the item with by checking the checkboxes adjacent to the label designators and values. It is possible to add a value to a drawing without the associated label designator, but a label designator may not be placed without the associated value.

Click OK.

12.18:153© 2011 AVEVA Solutions Ltd

Page 542: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

5. The Command prompt will then display:

Pick insertion point:

Pick the required point on the drawing for the first UDA label that was selected in the dialog. The first label designator will then be added to the drawing. Repeat for all selected label designators and their values.

If the Fix position of designators checkbox was checked, all label designators and values are added in one go, their positions determined by the values in the X Offset and Y Offset fields.

8.6.34 Removing UDAs from Symbols

• DescriptionUser-Defined Attributes (UDAs) can be defined for symbol types using the Symbol Editor.

This procedure is used to remove all such User-Defined Attributes from selected symbols on a drawing.

DataSet UDAs are not removed by this procedure.

For details of the use of this procedure in the context of drawing P&IDs, see 6.12: Adding User-Defined Attributes.

• Instructions 1. Start the procedure by entering REMOVEUDAS at the command prompt. 2. The Command prompt will display:

Select objects:

Select the objects from which UDAs are to be removed.

If all UDAs are to be removed from all objects, enter "all" at the command prompt.3. Press Enter. UDAs are then removed from all the objects on the drawing that have the

same symbols as the selected objects. For example, if a Ball Valve symbol is selected, UDAs are removed from all objects on the drawing that are represented with that symbol.

A message is displayed indicating the number of UDAs removed.

12.18:154© 2011 AVEVA Solutions Ltd

Page 543: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. The Command prompt will then display:

Select objects:

Select more objects to remove UDAs from, or select Cancel from the drawing page menu or press Ctrl-C to end the command.

12.18:155© 2011 AVEVA Solutions Ltd

Page 544: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.7 Modifying Drawings

8.7.1 Copying Drawing Objects and Labels

• Description This procedure is used to copy items and, optionally, associated labels.

Note: Nozzles copied from one vessel to another are automatically associated with the new vessel.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

Note: Valves and reducer symbols may be restricted so that they can only be inserted into pipes with specific codes and sizes. These are specified using the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program. When a symbol is moved onto a pipe, the system checks that it is valid for the code and size of the pipe. If it is not, the move may be prevented, or a warning displayed, depending on the project setup.

• Instructions Before copying and pasting, a user should be familiar with Notes on Copying and Pasting.

1. Start the procedure by either: • selecting the object(s) and/or label(s) to be copied on The Drawing Page, then:

• selecting Copy from the shortcut menu, or • entering VPECOPYCLIP at the Command prompt

Continue at step 2.

or:• selecting the Copy option in Modify Group of the Home Tab, or• entering VPECOPYPASTE at the Command prompt.

Continue at step 4.

or:• selecting the object to be copied in the Engineering Explorer, then selecting Copy

from the shortcut menu (only pipes may be copied using this method),

Continue at step 6.2. If the first method is selected, and multiple items were selected, the command prompt

will display:

Pick a base point:

Select the logical base point from which the items are to be copied.

If a single item was copied, the above prompt is not displayed.

If copying a single item of type NOZ, EQE, ICD or LCK, see Copying a Single Owned Item for further instructions. If not proceed as described below.

12.18:156© 2011 AVEVA Solutions Ltd

Page 545: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. If copying to another drawing, open that drawing. Proceed by: • selecting Paste from The Drawing Page shortcut menu, or• entering VPEPASTECLIP at the command prompt.

The command prompt will display:

Pick a point to paste:

Select the point on the drawing that the selected item or items are to be pasted to. The copy than takes place.

4. If the second method is selected, the command prompt will display:

Pick a base point:

Select the logical base point from which the items are to be copied.

If a single item was copied, the above prompt is not displayed.

If copying to another drawing, open that drawing.5. The Command prompt will then display:

Pick a point to paste:

Select the point on the drawing that the selected item or items are to be pasted to. The copy than takes place.

6. If the third method is selected, the command prompt will then display:

Pick a base point:

Select the logical base point from which the pipe is to be copied. 7. The Command prompt will then display:

Pick a point to paste:

Pick the point for the item to be copied to. The copy then takes place.

Note: If the Engineering Explorer copy method is used to copy a pipe, all inline items will also be copied. Off line items will not be copied.

• Notes on Copying and Pasting• All or part of copied labels will be replaced by the project null character (e.g.?), so that

they do not duplicate the original label and preserve the label uniqueness. For labels that contain multiple fields the Number field is nulled in this way.

12.18:157© 2011 AVEVA Solutions Ltd

Page 546: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• If a pipe is copied, the user will be prompted to specify on pasting whether the copy of the pipe is a new pipe, a branch pipe or a trim pipe, i.e.:

Indicate owner Pipe for Branch, or \n Trim Label for Trim pipe (<ret> for new pipe):

If the copy is a branch or a trim pipe, the owner pipe or vessel trim must be selected.• Inline items such as valves and reducers may only be copied from one pipe to another,

which will be broken correctly by the pasted items. • If more than one inline item is copied, the complete pipe group (i.e. all the pipe

segments, branches and all other inline items) and associated labels will be copied as well.

• If one or more pipe segments, or the either the start or end node of a pipe is copied, the complete pipe group and associated labels will be copied as well.

• If equipment is copied, all of the equipment nozzles and associated labels are copied as well.

• Nozzles copied from one vessel to another are automatically associated with the new vessel. Nozzle labels are copied as well.

• If a pipe label is copied, the entire pipe group is also copied as well. Labels of other items can be copied without copying the associated symbols.

• If a leader line or label balloon is copied, the owning item (i.e. the valve or flow element) is also copied.

• If a spec break is copied, any associated labels will NOT be copied.• If a cloud is copied, associated symbols will also be copied.• If an instrument that is in an instrument loop is copied, the copy of the instrument is not

assigned to the instrument loop of the original instrument. It is placed into the default UNNAMED instrument group in the Engineering Explorer, indicating that it is not in an instrument loop.

• Copying a Single Owned ItemItems of types NOZ, EQE, ICD, or LCK must be "owned", i.e. associated on a P&ID with an owner item. If a single instance of one of these types was selected when the copy procedure is initiated using the first method of starting the copy procedure (as listed above), once the paste command is selected the procedure is different from other item types, as described below:

- Instructions• Nozzles (NOZ) - if the Labels Checkbox is Unchecked• Nozzles (NOZ) - if the Labels Checkbox is Checked• Electrical Equipment (EQE)• Interlocks and Conditioners (LCK, ICD)

12.18:158© 2011 AVEVA Solutions Ltd

Page 547: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Nozzles (NOZ) - if the Labels Checkbox is Unchecked

1. The following sequence of command prompts will be displayed:

<Base point or displacement>/Multiple:

Hit <ESC> to cancel, Second Point of Displacement:

Indicate point to show angle of

Pick a logical base point on or off the item, or enter 'M' if multiple copies are required.

Then select a destination point on a valid owner item (EQU or EQV item type), and indicate the rotation angle. The copy will then take place.

2. If the selected destination point does not coincide with an owner item the application will prompt for valid owner to be selected.

Select Owner Item:

If the Multiple Copy option was not selected then the command will be terminated. Otherwise the [Second point of displacement:] prompt will be repeated enabling placement of the required number of copies.

3. If an invalid item is selected as the owner and the Multiple Copy option was not selected, an error message will be displayed, and the application will return to the command prompt:

ERROR: 231 Invalid AVEVA P&ID type selected.

Command:

4. If the Multiple Copy option was selected, the following is displayed:

ERROR: 231 Invalid AVEVA P&ID type selected.

Hit <ESC> to cancel, Second Point of Displacement:

Select a valid owner item or select <Esc> to end the command.

- Nozzles (NOZ) - if the Labels Checkbox is Checked

Note: If nozzle does not have any labels then the procedure will be the same as if the checkbox was not checked. See above.

1. The following command prompts will be displayed:

<Base point or displacement>/Multiple:

Hit <ESC> to cancel, Second Point of Displacement:

12.18:159© 2011 AVEVA Solutions Ltd

Page 548: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pick a logical base point on or off the item, or enter 'M' if multiple copies are required.

Then select a destination point on a valid owner item (EQU or EQV item type). The rotation angle will be identical to source entity, and therefore will not be prompted for.

The copy will then take place. Nozzle tag and size labels will be copied as well. 2. If the selected destination point does not coincide with an owner item the application

will prompt for valid owner to be selected.

Select Owner Item:

If the Multiple Copy option was not selected then the command will be terminated. Otherwise the [Second point of displacement:] prompt will be repeated enabling placement of the required number of copies.

3. If an invalid item is selected as the owner and the Multiple Copy option was not selected, an error message will be displayed, and the application will return to the command prompt:

ERROR: 231 Invalid AVEVA P&ID type selected.

Command:

4. If the Multiple Copy option was selected, the following is displayed:

ERROR: 231 Invalid AVEVA P&ID type selected.

Hit <ESC> to cancel, Second Point of Displacement:

Select a valid owner item or select <Esc> to end the command.

- Electrical Equipment (EQE)

Note: If the Labels checkbox is checked, the equipment label will be copied along with the equipment. However, the procedure the user follows is the same regardless of whether or not the Labels checkbox is checked.

1. The following command prompts will be displayed:

<Base point or displacement>/Multiple:

Hit <ESC> to cancel, Second Point of Displacement:

________________________________________

Pick a logical base point on or off the item, or enter 'M' if multiple copies are required.

Then select a destination point on a valid owner item (EQU or EQV item type).

The copy will then take place. If the Labels checkbox is checked, the equipment tag label will be copied as well.

12.18:160© 2011 AVEVA Solutions Ltd

Page 549: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. If the selected destination point does not coincide with an owner item the application will prompt for valid owner to be selected.

Select Owner Item:

If the Multiple Copy option was not selected then the command will be terminated. Otherwise the [Second point of displacement:] prompt will be repeated enabling placement of the required number of copies.

3. If an invalid item is selected as the owner and the Multiple Copy option was not selected, an error message will be displayed, and the application will return to the command prompt:

ERROR: 231 Invalid AVEVA P&ID type selected.

Command:

4. If the Multiple Copy option was selected, the following is displayed:

ERROR: 231 Invalid AVEVA P&ID type selected.

Hit <ESC> to cancel, Second Point of Displacement:

Select a valid owner item or select <Esc> to end the command.

- Interlocks and Conditioners (LCK, ICD)

Note: Neither of these item types has labels, so the procedure is the same regardless of whether or not the Labels checkbox is checked.

1. The following command prompts will be displayed:

<Base point or displacement>/Multiple:

Hit <ESC> to cancel, Second Point of Displacement:

Pick a logical base point on or off the item, or enter 'M' if multiple copies are required.

Then select a destination point on a valid owner item (INS or ILB item type). The rotation angle will be identical to source entity, and therefore will not be prompted for.

The copy will then take place. The equipment tag label will be copied as well. 2. If the selected destination point does not coincide with an owner item the application

will prompt for valid owner to be selected.

Select Owner Item:

12.18:161© 2011 AVEVA Solutions Ltd

Page 550: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the Multiple Copy option was not selected then the command will be terminated. Otherwise the [Second point of displacement:] prompt will be repeated enabling placement of the required number of copies.

3. If an invalid item is selected as the owner and the Multiple Copy option was not selected, an error message will be displayed, and the application will return to the command prompt:

ERROR: 231 Invalid AVEVA P&ID type selected.

Command:

4. If the Multiple Copy option was selected, the following is displayed:

ERROR: 231 Invalid AVEVA P&ID type selected.

Hit <ESC> to cancel, Second Point of Displacement:

Select a valid owner item or select <Esc> to end the command.

8.7.2 Moving Drawing Objects

• Description This procedure is used to move objects and their labels around the drawing. Multiple objects can be moved with one use of this procedure. Nozzles may be moved around on the vessel with which they are associated with, but not between vessels.

Labels are moved automatically with their associated objects.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

Note: Valves and reducer symbols may be restricted so that they can only be inserted into pipes with specific codes and sizes. These are specified using the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program. When a symbol is moved onto a pipe, the system checks that it is valid for the code and size of the pipe. If it is not, the move may be prevented, or a warning displayed, depending on the project setup.

Note: If pipe flags (i.e. page connector) and associated labels are selected andthen the "Move" command is selected (i.e. using the first method described below), the "Stretch" command is activated instead, i.e. in the case of pipe flags and pipe flag labels this procedure is used to stretch them instead of move them. See 8.7.4: Stretching Drawing Objects.

• Instructions 1. Start the procedure by either:

• selecting the object(s) to be copied on The Drawing Page, then selecting:• Cut from the shortcut menu, or • Ctrl+X on the keyboard.

12.18:162© 2011 AVEVA Solutions Ltd

Page 551: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

or:• selecting the object(s) to be copied in the Engineering Explorer, then selecting

Move from the shortcut menu, or • selecting the Move option in Modify Group of the Home Tab.

2. If the first method of starting the procedure is selected, proceed by: • selecting Paste from The Drawing Page shortcut menu, or • entering Ctrl+V on the keyboard.

If this method is used, inline items such as valves and reducers may be moved from one pipe to another, which will be broken correctly by the pasted item.

3. The command prompt will display:

Indicate point for <Item name>:

Click on the point that the object is to be moved to. The object(s) will then be pasted at the point.

4. If the second (Engineering Explorer) method of starting the procedure is selected, the command prompt will then display:

Base point:

Pick a logical basepoint on or off the item(s). 5. The Command prompt will then display:

Second point of displacement:

Pick the point for the item(s) to be moved to. All the selected objects are then repositioned and the command ends then automatically.

6. If either of the other two methods of starting the procedure is selected, the command prompt will display:

Select objects:

Select each object to be moved.

Press or select Enter to end object selection. 7. The Command prompt will then display:

Base point:

Pick a logical basepoint on or off the item(s). 8. The Command prompt will then display:

12.18:163© 2011 AVEVA Solutions Ltd

Page 552: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Second point of displacement:

Pick the point for the item(s) to be moved to.

All the selected objects are repositioned.

The command then ends automatically.

8.7.3 Mirroring Drawing Objects

• Description This procedure enables mirroring of a selected item. Text is not affected. Mirroring operates almost identically to the AutoCAD command, the difference being that there is no choice of retaining original items.

Do not mirror angled valves, as this will cause validation errors.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

• Example

• Instructions 1. Start the procedure by selecting the Mirror option in Modify Group of the Home Tab.2. The Command prompt will display:

Select objects:

Press Enter to end object selection.

12.18:164© 2011 AVEVA Solutions Ltd

Page 553: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The Command prompt will then display:

First point of mirror line:

Pick one end of the mirror line; a 'ghost' of the reflected image appears. 4. The Command prompt will then display:

Second point of mirror line:

Pick the other end of the line. The command performs the reflection, deletes the old object and ends automatically.

8.7.4 Stretching Drawing Objects

• Description This procedure is used to stretch items and groups of items. There are two methods:

Grips can be used. These operate much like standard AutoCAD grips.

If grips are not used, the procedure is similar to the Moving Drawing Objects procedure except that the items retain connections with other objects.

Because connections between items are maintained as stretching occurs, ensure that all items to be stretched are selected, or the stretch may have unexpected results.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

Note: Pipe flags (i.e. page connectors) and their labels can also be stretched using the Moving Drawing Objects procedure. See 8.7.2: Moving Drawing Objects.

• Instructions• Using Grips• Grips Not Used

- Using Grips

1. Start the procedure by selecting the items that are to be stretched. The grips of the selected items are then displayed as blue squares.

2. From the grips of the selected items, select a base grip or grips. To select multiple grips, hold down Shift while selecting. The selected grips are displayed as red squares.

12.18:165© 2011 AVEVA Solutions Ltd

Page 554: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. Click on the point towards which the selected items are to be stretched.

The items stretch to this point while retaining their connections. The command then ends automatically (unlike in AutoCAD, it is not necessary to press Esc).

Note: Only the Stretch grip mode is available in AVEVA P&ID. Other AutoCAD grips modes, such as Move and Rotate, are not currently available.

- Grips Not Used

1. Start the procedure by selecting the Stretch option in Modify Group of the Home Tab.

An automatic 'crossing' selection is activated. 2. The Command prompt will display:

First corner:

Pick first corner. 3. The Command prompt will then display:

Other corner:

Pick second corner.

The chosen entities are highlighted. 4. The Command prompt will then display:

Remove objects:

Remove any items which have been selected by mistake by picking them now.

Press or select Enter when finished.

12.18:166© 2011 AVEVA Solutions Ltd

Page 555: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

5. The Command prompt will then display:

Base point:

Pick a logical base point to move. 6. The Command prompt will then display:

Second point of displacement:

Pick a point for the base point to move to.

The items move while retaining their connections. The command then ends automatically.

8.7.5 Rotating Drawing Objects

• Description This procedure is used to rotate items.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

• Instructions 1. Start the procedure by either:

• selecting Rotate from the shortcut menu without selecting any objects, or• selecting the Rotate option in Modify Group of the Home Tab without selecting any

objects, or• selecting the object(s) to be rotated on The Drawing Page, then selecting Rotate

from the shortcut menu, or • selecting the object(s) to be rotated on the drawing page, then selecting the Roate

option in Modify Group of the Home Tab, or • selecting the object(s) to be rotated on The Drawing Page, then pressing either

Ctrl+R or Ctrl+L on the keyboard.2. If the first or second methods of starting the procedure are followed, the command

prompt will display:

Select objects for Rotating (Select using Crossing[C] or Crossing Polygon[CP]):

Select the object or objects to be rotated.

If the third, fourth or fifth methods of starting the procedure were selected, the objects will already have been selected.

12.18:167© 2011 AVEVA Solutions Ltd

Page 556: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. If multiple items were selected, the command prompt will display:

Pick rotation base point:

Pick a point around which the selected objects are to be rotated. If a single object was selected, this prompt is not displayed. The single object is rotated around its insertion point.

4. If one of the first four methods of starting the procedure was selected, the command prompt will then display:

Pick a point to specify the rotation angle:

Select a point on the drawing to indicate the angle at which the selected object or objects are to be rotated. The rotation then takes place.

If the fifth method of starting the procedure was selected, this prompt is not displayed. If Ctrl+R was pressed, the object is rotated 90o to the right. If Ctrl+L was pressed, the object is rotated 90o to the left.

8.7.6 Deleting Drawing Objects

• Description This procedure is used to delete items and groups of items as one entity. The consequences of using this procedure vary according to the situation and the types of items being deleted, e.g. associated items are deleted as one entity, prompts are given for a size to be retained if a labelled reducer is deleted, etc.

Note: If a reducer is deleted, the pipe segment that the reducer was inserted into adopts the size of the segment that was upstream of the deleted reducer.

For details of the use of this procedure in the context of drawing P&IDs, see 6.18: Deleting Items.

• Instructions 1. Start the procedure by either:

• selecting the object(s) to be deleted on The Drawing Page, then selecting Deletefrom the shortcut menu, or

• selecting the object(s) to be deleted on The Drawing Page, then pressing Delete on the keyboard, or

• selecting the object(s) to be deleted in the Engineering Explorer, then selecting Delete from the shortcut menu, or

• selecting the Delete option in Modify Group of the Home Tab.2. If one of the first three methods of starting the procedure is followed, the deletion Is

carried out immediately on the selected objects.

12.18:168© 2011 AVEVA Solutions Ltd

Page 557: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

If the last method is followed, the Command prompt will display:

Select objects:

Selected objects will indicated by dashed lines.

Press or select Enter and the highlighted entities are deleted. 3. By whatever method objects are selected, if you pick, for example, a vessel, then all its

associated nozzles, trim pipe labelling and electrical equipment become highlighted as well.

8.7.7 Exchanging Individual Symbols

• Description This procedure exchanges symbols individually (exchanges one symbol for another). The symbol with which a symbol is to be exchanged must be already in existence and be of the same AVEVA P&ID type. For example, a CL (column) could be exchanged with a HDT (head tank) because they are both of the EQV item type in AVEVA P&ID. If the new symbol is a different size, AVEVA P&ID will make adjustments to allow for this. All labelling (including balloons) is retained.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

See also 8.7.8: Exchanging Symbols Globally.

Note: Valves and reducer symbols may be restricted so that they can only be inserted into pipes with specific codes and sizes. These are specified using the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program. When a symbol is exchanged, the system checks that the symbol selected to replace the old symbol is valid for the code and size of the pipe. If it is not, the exchange may be prevented, or a warning displayed, depending on the project setup.

• Instructions 1. Start the procedure by selecting the Exchange Symbol option in Symbol Group of the

Home Tab.

12.18:169© 2011 AVEVA Solutions Ltd

Page 558: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. The AVEVA P&ID Symbol List dialog appears:

Select the category of symbol from the left-hand window, and then the name of the symbol from the left-hand window. If the name of the symbol is known, but not its category, enter the name of the symbol in the Find field, and click on the Find button. To select a symbol, click on it in the right-hand window. An image of it is displayed in the lower half of the dialog box, along with the symbol name and description. Press the OK button.

3. The Command prompt will display:

Select Item:

12.18:170© 2011 AVEVA Solutions Ltd

Page 559: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pick an item on the P&ID to exchange for the new item. Subsequent prompts vary here depending on the item being inserted; for example, you may be prompted for scale and rotation of equipment etc. Once the symbol exchange has taken place, you will be prompted to select another item for exchange. Proceed as above or select Cancel from The Drawing Page shortcut menu, or enter Ctrl-C to cancel the command.

8.7.8 Exchanging Symbols Globally

• Description This procedure is used to globally exchange similar groups of AVEVA P&ID symbols. Client symbols may be converted using this procedure.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

See also 8.7.7: Exchanging Individual Symbols.

Note: Valves and reducer symbols may be restricted so that they can only be inserted into pipes with specific codes and sizes. These are specified using the Spec Driven Configuration Category of the AVEVA P&ID Project Administration program. When a symbol is exchanged, the system checks that the symbol selected to replace the old symbol is valid for the code and size of the pipe. If it is not, the exchange may be prevented, or a warning displayed, depending on the project setup.

• Errors An error message occurs when the AVEVA P&ID mapping file is in the wrong directory. In this case, move the PID.BEX file in which the mappings are stored into the working directory where the drawings reside.

• Instructions 1. Start the procedure by selecting the Global Symbol Exchange option in Symbol

Group of the Home Tab.

AVEVA P&ID then performs a Zoom All. The symbols change dynamically on the drawing as the exchange proceeds.

8.7.9 Moving Items to the Non-Plot Layer

• Description This procedure is used to move item(s) to the non-plotting layer (toggles items between the non-plotting layer/level and their original layer/level). If items are subsequently selected again using the same procedure, they will move back to the layer that they originally came from.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

• Associated Project Configuration Options • The non-plot layer is selected on the Miscellaneous - Settings Sub-Set of the AVEVA

P&ID Project Administration program. • Layers are configured using the Drawing - Layers Sub-Set.

12.18:171© 2011 AVEVA Solutions Ltd

Page 560: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by selecting the Change to Non-Plot Layer option in Modify Group

of the Home Tab. 2. The Command prompt will display:

Select objects:

Pick the item(s) to be moved to the non-plotting layer, either individually or by window, crossing etc.

3. Press Enter, and the command will end automatically after the entities have moved.

Note that the items will not change to the colour of the non-plotting layer.

8.7.10 Drawing Revision Clouds

• Description This procedure is used to highlight changes from a previous revision of a drawing by adding a cloud of any size around the desired area. Clouds can only be deleted as a complete entity using the AVEVA P&ID delete facilities and cannot be copied or broken. Clouds should always be drawn in a clockwise direction.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

• Example

• Instructions 1. Start the procedure by selecting the Revision Cloud option in Symbol Group of the

Home Tab. 2. The Command prompt will display:

Indicate point for cloud (Enter 'C' to close):

12.18:172© 2011 AVEVA Solutions Ltd

Page 561: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Pick points in a clockwise direction until the cloud is large enough and then enter 'C' to close it.

8.7.11 Changing the Colours of Multiple Items

• DescriptionThis procedure is used to change the colours of multiple items on multiple drawings within a project, based on their AVEVA P&ID properties or based on the VPE Workbench labels that the items are labelled with (see 8.8.9: Labelling with VPE Workbench Data), and the association of VPE Workbench values in tables of such values on the drawings.

Such tables are generated using Design Data Templates (DDT) and the Inserting Assemblies procedure (see 8.4.11: Inserting Assemblies).

The process creates copies of the selected drawings and applies the re-colouring procedure to them. The original drawings are not changed.

The selection of drawings, the item selection criteria and the re-colouring process itself is carried out using the AVEVA P&ID Colouring Utility application.

For details of the use of this procedure in the context of drawing P&IDs, see 6.17: General Editing, Notes and Revision Clouds.

• Instructions

- Preliminary Requirements

If colours are to be changed using criteria based on VPE Workbench labels that items are labelled with, all drawings that are to be subject to the procedure must:

• be synchronised and their output files available.• include a table of VPE Workbench values generated using a DDT which maps VPE

Workbench values as described below.

- Overview

In the AVEVA P&ID Colouring Utility application, an AVEVA P&ID project is selected, from which drawings to be subject to the procedure are then selected.

If colours are to be changed based on the AVEVA P&ID properties of item, the procedure is relatively simple. The user may simply specify, for example, that all Instruments with a tag prefix value of "ABC" will be changed to a selected colour.

If colours are to be changed using criteria based on VPE Workbench labels that items are labelled with, the user may specify whether colouring changing rules are to be based on the mappings of VPE Workbench values in tables in the individual drawings, or on those within a selected template drawing.

The user must then specify the criteria for changing the colours of items based on their VPE Workbench labels and the mappings of the label values in the VPE Workbench value table(s), plus the colour that items are to be changed to.

12.18:173© 2011 AVEVA Solutions Ltd

Page 562: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Examples:

Example 1: It is required that all items labelled with a specific design area "A" are to be re-coloured. The design area is in the VPE Workbench value table(s). It is therefore sufficient to specify in the Colouring Utility project settings items that all items labelled design "A" area are to be changed to the specified colour, and to set up the column mapping as explained below.

Example 2: It is required that all items with a specific safety class are to be re-coloured. Items on the drawings are not labelled with their safety class. However they are labelled, using a VPE Workbench label, with their design area. Every design area and safety class is mapped on the table(s) of VPE Workbench values. For example, safety class SC1 is mapped to design area A1 (i.e. they are in the same row in the table).

Therefore, in order to change the colour of all the items with a specific safety class of SC1, it is necessary to specify in the Colouring Utility project settings that items with a safety class of SC1 are to be subject to the procedure and to specify that the safety class column in the VPE Workbench value table(s) is mapped to the design area column.

When the procedure is implemented, the utility will refer to the VPE Workbench value table(s). It will find all entries in the safety class column with a value of SC1. It will then refer to the design area column to find all the design areas that are mapped to that safety class, i.e. in the same row in the table. It will then refer to the drawing to find all the items that are labelled with those design areas, and change them to the specified colour.

Colouring Utility project settings may be saved for future use.

- Opening the AVEVA P&ID Colouring Utility

Select AVEVA > P&ID > AVEVA P&ID Colour Utility > AVEVA P&ID Colour Utility from the Programs menu.

The Create or Open Setting Project dialog is then displayed (see below).

- Creating and Opening Colouring Settings Projects

To create a new settings project:

1. In the Create or Open Setting Project dialog, select the Create a New Setting option.

2. Enter the name if the project in the Project Name field.

12.18:174© 2011 AVEVA Solutions Ltd

Page 563: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. Enter the location of the project in the Setting File field, or press this button and browse for the required file.

4. Select the Create Project button. The AVEVA Colouring Utility dialog is then displayed (see below).

To open an existing settings project:

1. Select the Open an Existing Setting option.

2. Enter the location and file name of the settings project file in the Setting File field, or

press this button and browse for the file.

Settings project files are .XML files. Their file names will be the same as the project names that were entered when they were created, as described above.

3. Select the Open Project button. The AVEVA Colouring Utility dialog is then displayed (see below).

12.18:175© 2011 AVEVA Solutions Ltd

Page 564: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Specifying Colouring Project Data and Selecting Drawings

1. In the Select Input Folder field, enter the folder in which the source drawings are located, or press the Browse button and browse for the location. Alternatively leave as the default location, which will be the project location folder selected in the Setting File field (see above), plus "\input".

The full location and file name of each AVEVA P&ID drawing in the selected input folder is the listed in the dialog.

2. In the Select P&ID Project File field, enter the location and file name of the configuration file (.PRJ) of the P&ID project associated with the source drawings, or press the Browse button and browse for the file. Alternatively leave as the default location and file name, which will be the default input folder location (see above), plus "\PID.PRJ".

3. In the Select Output Folder field, enter the folder in which the re-coloured drawings are to be placed, or press the Browse button and browse for the location. Alternatively leave as the default location, which will be the project location folder selected in the Setting File field (see above), plus "\output".

4. If colours are to be changed using criteria based on VPE Workbench labels that items are labelled with, in the Select Template Drawing field, enter the location and file name of the drawing file (.DWG) which is to serve as the template file for the project. The template file must contain a VPE Workbench value table of all the values that are used when specifying which items are to be re-coloured.

12.18:176© 2011 AVEVA Solutions Ltd

Page 565: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

It is from this drawing that the lists of property names and column names are derived which are used when specifying colouring criteria (see below).

5. If re-colouring rules are to be applied based on the relationships between VPE Workbench values in the table on the template file, check the Change According to Template checkbox. If they are to be applied based on the relationships found in each drawing, uncheck this checkbox.

For instance, if in the template drawing Safety Area SC3 matching design area G, A and B, but in your target drawing safety area SC3 matches only design area G, when the checkbox is checked, all pipes, equipment, and off-line instruments with design areas A ,B and G will be coloured. If it is unchecked, only those items with design area G will be coloured.

6. If all the P&ID drawings found in the input folder are to be subject to the procedure, select the Select All checkbox. If only certain drawings are to be re-coloured, check or uncheck the Select File checkboxes for the individual drawings as required.

7. To specify which items on the drawings are to be re-coloured, select the Settingsbutton. The Colouring Criteria dialog is then displayed (see below).

12.18:177© 2011 AVEVA Solutions Ltd

Page 566: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Specifying Colouring Criteria

This dialog is used to set up the criteria for re-colouring items. These criteria consist of one or more rules.

To set up a simple rule to change the colour of items based on their AVEVA P&ID properties:

1. From the Item Type field, select either Equipment, Instrument or Pipe, depending on the type of items to be re-coloured.

2. In the Matching Criteria window, select the AVEVA P&ID property of the items to be re-coloured from the list in the Property Name field.

3. Select the “Equals” condition from the Condition field. 4. In the Value field, enter the value of the selected property that the selected condition is

to be applied to.

12.18:178© 2011 AVEVA Solutions Ltd

Page 567: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

5. Select the Pick Colour button and from the dialog that is then displayed, choose the colour that items will be re-coloured in.

6. Select the Add Rule button. The rule is then added to the rules in the Rule set window

If colours are to be changed using criteria based on VPE Workbench labels that items are labelled with, to set up a simple rule like that in Example 1 (above):

1. In the Matching Criteria window, select the VPE Workbench property of the items to be re-coloured from the list in the Property Name field.

2. Select the “Equals” condition from the Condition field. 3. In the Value field, enter the value of the selected property that the selected condition is

to be applied to. 4. Select the Pick Colour button and from the dialog that is then displayed, choose the

colour that items will be re-coloured in.5. Select the Add Rule button. The rule is then added to the rules in the Rule set window.

12.18:179© 2011 AVEVA Solutions Ltd

Page 568: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

6. Set up the mapping by selecting the Define Alias Field button. The Field Mapping Settings dialog is then displayed.

Note: Lists of values for the fields in this dialog will be available if a template drawing has been specified (see above). Otherwise fields must be completed by manual entry.

Note: It is always necessary to specify a mapped column and a mapped field name, even if one column is not being mapped to another. In such a case, the same column and field details must be specified in both sets of fields.

7. In the Primary Column Name field, select the identifier of the column on the template drawing in which the selected property is located.

8. The adjacent Field Name field displays the alias of the selected column, i.e. the name by which is known on the drawing.

9. In the Mapped Column Name field, enter the same identifier as entered on the Primary Column Name field

10. In the adjacent Mapped Field Name field enter same alias as entered in the Field Name field.

11. Select the Save button to save the mapping and close the dialog.

Therefore in order to set up the criteria for applying the re-colouring of items with a specific design area, as described in Example 1 (above):

• Select "Design Area" from the list in the Property Name field.• Select "Equals" in the Condition field.• Select "A" in the Value field.• In the Field Mapping Settings dialog, select the identifier of the design area column in

the Primary Column Name field.• Enter "Design Area" in the Field Name field.• Select the identifier of the design area column in the Mapped Column Name field.• Enter "Design Area" in the Mapped Field Name field.

Note: The Item Name field is not currently used.

If colours are to be changed using criteria based on VPE Workbench labels that items are labelled with, to set up a more complex rule like that in Example 2 (above):

1. Proceed as above, but in the Property Name field, select the property on the VPE Workbench values table that is to be mapped to the property labelling the items.

12.18:180© 2011 AVEVA Solutions Ltd

Page 569: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. Set up the mapping by selecting the Define Alias Field button. The Field Mapping Settings dialog is then displayed.

Note: The settings shown in the image above are the default settings for this dialog.

3. In the Primary Column Name field, select the identifier of the column on the template drawing in which the selected property is located.

4. The adjacent Field Name field displays the alias of the selected column, i.e. the name by which is known on the drawing.

5. In the Mapped Column Name field, select the column containing the properties that are to be mapped to.

6. In the adjacent Mapped Field Name field enter the alias of this column.7. Select the Save button to save the mapping and close the dialog.

Note: The identifier of a column can be found on the drawing by selecting the column and using the List Item Details procedure. The identifier will be listed in a line that will look something like this:

*Code 1000, Designator: $Pid System.1.Text Field Value

...where "$Pid System.1.Text Field Value" is the identifier.

Therefore in order to set up the criteria for applying the re-colouring of items with a specific safety class, as described in Example 2 (above):

• Select "Safety Class" from the list in the Property Name field.• Select "Equals" in the Condition field.• Select "SC1" in the Value field.• In the Field Mapping Settings dialog, select the identifier of the safety class column. • Enter "Safety Class" in the Field Name field• Select the identifier of the design area column in the Mapped Column Name field.• Enter "Design Area" in the Mapped Field Name field.

12.18:181© 2011 AVEVA Solutions Ltd

Page 570: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

- Specifying Multiple Colouring Criteria Rules

The colouring criteria may consist of multiple rules. Once the basic details of the first rule are completed by specifying a value in the Value field, another row of fields is then displayed underneath the first in the Matching Criteria window, which can be used for specifying another rule.

Set up this rule as described above. In addition, in the Join Criteria field, select “OR”.

Add any additional rules using the same procedure.

- Performing the Colour Changing Operation

On the Colouring Criteria dialog save the rule settings and close the dialog by selecting the Save Settings button.

On the AVEVA Colouring Utility dialog, select the Process button. The colour changing operation then takes place.

When a drawing has been processed successfully, a green tick is displayed in its Progress field. A red cross is displayed if the drawing is processed with errors.

To stop the operation, select the Cancel button.

Once a drawing has been processed, details of errors and warnings can be viewed by selecting its View Log File button.

- Resetting and Saving Settings

To reset the Colouring Utility project settings to those last saved, select the Reset button.

To save the settings, select the Save button.

Close the AVEVA P&ID Colouring Utility by selecting the Exit button.

12.18:182© 2011 AVEVA Solutions Ltd

Page 571: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.8 Data Transfer

8.8.1 Checking for Corrupted Items

• Description This procedure is used to check the drawing for corrupted items.

• Instructions 1. Start the procedure by selecting the Audit option in Project Configuration Group of the

Utilities Tab. 2. All "intelligent" items on the drawing, both pipes and symbols, are then checked. If any

are found to be corrupted, an error balloon is placed at item insertion point, displaying the following message:

ERROR: 381 Entity is Corrupted, Please Delete it from Drawing. - Handle: [item handle]

8.8.2 Exporting Data to a P&ID Reports Database

• DescriptionThis procedure is used to:

• Validate a drawing.• Export data from drawings in unconsolidated form to an intermediate "raw" database,

from where it must subsequently be consolidated using AVEVA P&ID Reports facilities.• Export data to a number of output files, from where it must subsequently be

consolidated using AVEVA P&ID Reports facilities.• Export consolidated drawing data directly into the AVEVA P&ID Reports database.

Note: Data can be exported to a VPE Workbench database at the same time at the same time as it is exported to an AVEVA P&ID Reports database. See 8.8.5: Synchronising Data with a VPE Workbench Database for details.

A database must be logged into with either Admin or Import rights before it can be exported to. See 8.8.3: Connecting to a P&ID Reports Database.

See also 7.1: Exporting Data to an AVEVA P&ID Reports Database for further details of the interface with P&ID Reports.

Details of the output files can be found in 9.2: Output File Format

• Associated Project Configuration Options• The directory into which output files are exported is set in the Save Path field on the

Project Configuration Category of the AVEVA P&ID Project Administration program. • The P&ID Reports database to which data is exported are specified on the P&ID

Reports Configuration Category.

12.18:183© 2011 AVEVA Solutions Ltd

Page 572: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• UDA values are displayed in AVEVA P&ID Reports on the UDA tab. Whether or not UDA values are also to be displayed on the same tabs as the items they are associated with is controlled by the setting of the Merge UDA Values checkbox on the P&ID Reports - Settings Sub-Set.

• The default settings of the Export to P&ID Reports and Export & Consolidate Database checkboxes on the Synchronise dialog box are controlled by the settings of the Update P&ID Reports after Synchronize and Update and Consolidate P&ID Reports Database after Synchronize checkboxes on the P&ID Reports - Settings Sub-Set.

• Whether or not comments regarding the export entered in the Description dialog (see below) are added to the P&ID Reports database is controlled by the setting of the Add P&ID Drawing Details to Database checkbox on the P&ID Reports - Settings Sub-Set.

• The line properties to be compared when attempting to consolidate lines present on multiple P&IDs in the P&ID Reports database are selected on the P&ID Reports - Settings Sub-Set.

Note: For the project configuration options related to drawing validation, exporting the VPE Workbench and other miscellaneous options, see the Synchronising Data with a VPE Workbench Database procedure.

• Instructions1. Start the procedure by either:

• selecting Synchronise from the drawing shortcut menu of the Engineering Explorer, or

• pressing F12 on the keyboard, or • selecting the Synchronise option in AVEVA Integration Group of the Data

Management Tab. 2. The Synchronise dialog box will then be displayed:

3. The Export Data to Publishing Area checkbox is only relevant to the Synchronising Data with a VPE Workbench Database procedure.

4. If data in unconsolidated form is to be exported to an intermediate or "raw" database, check the Export to P&ID Reports checkbox. This checkbox is greyed out if the Export & Consolidate Database checkbox (see below) is checked.

5. If an AVEVA P&ID Reports database is to be populated with the exported data in consolidated form, check the Export & Consolidate Database checkbox. Note that if this option is selected the synchronisation procedure may take longer to complete.

6. If data is to be exported to a number of output files, uncheck both checkboxes.

12.18:184© 2011 AVEVA Solutions Ltd

Page 573: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

7. To enter a description or comments regarding this synchronisation process select the Add/Edit Description button. The Description dialog is then displayed:

Enter the required description and select the OK button.

Note: If a description is not entered before the synchronisation process is started, the Description dialog may be displayed automatically during the process depending on the project configuration (see above).

8. To initiate the synchronisation procedure, select the Synchronise button.

The progress of the procedure is displayed using a progress bar, and a count of the number of tasks successfully completed or failed.

While synchronisation is in progress the label of Synchronise button changes to Cancel. Select this button to abort the procedure.

9. If the Export & Consolidate Database checkbox is checked, and if the P&ID Reports database has not already been logged into, a dialog is displayed into which the password for the P&ID Reports database must be entered. See 8.8.3: Connecting to a P&ID Reports Database. A P&ID Reports database must be logged into with either Admin or Import rights before it can be exported to.

10. If a description of the export was not entered before the synchronisation process was started (see above), the Description dialog may be displayed automatically during the process (depending on the project configuration). Enter a description as required and select the OK button

12.18:185© 2011 AVEVA Solutions Ltd

Page 574: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

11. Select the Details >> button to view further details. The Details pane is then displayed.

Connection details are also displayed in this pane, at bottom of the dialog. 12. The Details pane consists of two tabs, Tasks and Details.

The Tasks tab displays the list of synchronisation tasks and the status of these tasks: Processing , Complete , Fail , or Pending.

12.18:186© 2011 AVEVA Solutions Ltd

Page 575: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

13. The Details tab displays processing details of each engineering item, i.e. error , warning and success messages.

14. If only error and warning messages are to be displayed, check the Show error and warning messages only checkbox.

15. Double-click on a message to select the item on the drawing. Any errors and warnings associated with the item can then be fixed. For details of errors and warning, and suggested solutions, see Error and Warning Messages.

Note: Error and warning messages are also added to the drawing. These can be deleted individually as required, or all them can be deleted at once using the Deleting Error Blocks procedure.

16. The Synchronise dialog box remains open so that further items can be selected and problems resolved.

17. A monitor file is generated by the synchronisation procedure, which lists the messages displayed in the Details tab. Select the View button to open this file in Notepad.

18. When synchronisation is complete the label of Cancel button changes to Close. Select this button to close dialog.

19. A redraw may be required at the end of the process to remove the highlighting which appeared during the pipe validation.

8.8.3 Connecting to a P&ID Reports Database

• Description This procedure is used to login to an AVEVA P&ID Reports database. A P&ID Reports database must be logged into before it can be opened from AVEVA P&ID, and must be logged into with either Admin or Import rights before it can be exported to.

See 7.1: Exporting Data to an AVEVA P&ID Reports Database for details of the interface with P&ID Reports.

12.18:187© 2011 AVEVA Solutions Ltd

Page 576: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration Options The name and location of the P&ID Reports database to which the connection is made is specified on the P&ID Reports Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions 1. If the P&ID Reports database has not already been logged into, this procedure starts

automatically (i.e. the PID Reports Login dialog is then displayed), when data is exported to a P&ID Reports database (see 8.8.2: Exporting Data to a P&ID Reports Database), or when a P&ID Reports database is opened (see 8.8.4: Opening a P&ID Reports Database).

To start the procedure "manually" select the Login option in P&ID Reports Group of the Data Management Tab.

The P&ID Reports Login dialog is then displayed:

Note: If no database is specified in the Project Administration program, the connection will automatically be to the default database (PidReports.mdw) supplied with the product.

2. Enter the password for the P&ID Reports database and press the OK button.

8.8.4 Opening a P&ID Reports Database

• DescriptionThis procedure is used to open and view an AVEVA P&ID Reports database.

See 7.1: Exporting Data to an AVEVA P&ID Reports Database for details of the interface with P&ID Reports.

• Associated Project Configuration Options The name and location of the P&ID Reports database which is opened is specified on the P&ID Reports Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by selecting the P&ID Reports Launch option in P&ID Reports

Group of the Data Management Tab.2. If the P&ID Reports database has not been logged into, a dialog is displayed into which

the password for the P&ID Reports database must be entered. See 8.8.3: Connecting to a P&ID Reports Database.

12.18:188© 2011 AVEVA Solutions Ltd

Page 577: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. AVEVA P&ID Reports is then launched, and the appropriate database opened. See AVEVA P&ID Reports documentation for details.

Note: If no database is specified in the Project Administration program, an Open dialog is displayed AVEVA P&ID Reports is opened from which the required database can be selected.

8.8.5 Synchronising Data with a VPE Workbench Database

• Description This procedure is used to:

• Validate a drawing • Synchronise drawing data with plant model data in a VPE Workbench project

database.• Transfer data to an sQL database for label uniqueness validation purposes (data may

also be transferred to an SQL database if, for example, a VPE Workbench database is not available).

Note: Data can be exported to an AVEVA P&ID Reports at the same time as it is exported to VPE Workbench. See 7.1: Exporting Data to an AVEVA P&ID Reports Databasefor details.

This procedure generates a number of output files. These may optionally be automatically copied to a specified publishing area, from where they are automatically imported into a specified VPE Workbench project.

Optionally, the output files may be transferred (or re-transferred) to the publishing area using facilities on the VPE Workbench pane of the AVEVA P&ID Project Administration program.

Details of the output files and the monitor file can be found in 9.2: Output File Format.

Note: The output files can also be transferred to a VPE Workbench database using facilities on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

The validation initiated using this procedure should not be confused with online data validation, which takes place during labelling.

For more details on the use of this procedure, see 7.5: Exporting Data to a VPE Workbench Database.

Note: If labels are validated against an SQL database, most label data is transferred to the database automatically on editing. However, some label data is only transferred when synchronisation takes place, i.e. data can be copied to the SQL database at the same time as it is being transferred to a VPE Workbench database. See 6.13.4: Label Validation across all Project P&IDs for details.

Note: If it is required to generate a simple line list from AVEVA P&ID using the Synchronise facility, line lists can be generated from "semi-intelligent" drawings, only partially upgraded from AutoCAD drawings (see 5: Upgrading AutoCAD Drawings), in which only the lines themselves are "intelligent" and any inline symbols are "dumb" AutoCAD blocks

12.18:189© 2011 AVEVA Solutions Ltd

Page 578: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration Options • The directory into which output files are exported is set on the Project Configuration

Category of the AVEVA P&ID Project Administration program. • During synchronisation, a copy of the drawing data can be made available for AVEVA

Model Management. In order for this to happen, the Save Copy checkbox on the Project Configuration Category must be checked.

• The SQL database location is specified on the Project Configuration Category. • The text colours of error and warning messages that may be displayed on drawings

when they are synchronized are specified using the Colour for warning and Colour for errors fields on the Miscellaneous – Settings Sub-Set.

• The service component that will handle the transfer of data to VPE Workbench is specified on the VPE Workbench Configuration Category.

• The VPE Workbench project with which the AVEVA P&ID project is to interface is specified on the VPE Workbench Configuration Category.

• The folder into which drawings are published when loading to the selected VPE Workbench project is specified on the VPE Workbench Configuration Category.

• The default setting of the Export & Consolidate Database checkbox on the Synchronise dialog box is set using the Export to VPE Workbench checkbox on the VPE Workbench Configuration Category.

• If when drawing data is to be loaded into the VPE Workbench project, users of that project are to receive e-mail messages to inform them of this, the project users are selected on the VPE Workbench Configuration Category.

• If the synchronisation process is to check that nozzle and pipe sizes match and to report any mismatches as errors, ensure that the Enforce Nozzle and Pipe Size Match checkbox on the Pipes - Settings Sub-Set is checked. If this checkbox is checked, any such mismatches must be corrected before the nozzles and pipes in question can be successfully synchronised

• If specification attributes of items are to be output, ensure the Populate in Database instead of Drawing checkbox on the Pipes - Settings Sub-Set is checked.

• If a warning message is to be displayed on the drawing for “unconnected” items, i.e. items for which owner details are not available, ensure that the Display owner warning checkbox on the Pipes – Settings Sub-Set is checked.

• If unlabelled nozzles are to result in a warning being displayed, ensure that the Nozzle Error-Balloon Placement checkbox on the Label Types Configuration Category is checked.

• If unlabelled reducers are to result in a warning being displayed, ensure that the "Reducer Not Labelled' Error-Balloon Placement checkbox on the Label Types Configuration Category is checked.

• If the Description dialog is to be displayed automatically during the synchronisation process, the Show Drawing History dialog box on the Drawing - Settings Sub-Set must be checked.

Note: See also 9.8: Setting up AVEVA P&ID to Connect with VPE Workbench.

• Instructions 1. Start the procedure by either:

• selecting Synchronise from the drawing shortcut menu of the Engineering Explorer, or

• pressing F12 on the keyboard, or • selecting the Synchronise option in AVEVA Integration Group of the Data

Management Tab, or

12.18:190© 2011 AVEVA Solutions Ltd

Page 579: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• entering NETOUTPUTBATCH at the Command prompt.

12.18:191© 2011 AVEVA Solutions Ltd

Page 580: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. Unless that last option was selected, the Synchronise dialog box will appear:

3. If the VPE Workbench project is version 5.8 or later, data can be exported immediatelyinto the VPE Workbench database. If this is required, check the Export Data to Publishing Area checkbox.

If checkbox is checked, the output files will automatically be copied into the publishing area as part of the synchronisation procedure, from where they will automatically be imported into the VPE Workbench database.

Note: If the checkbox is greyed out this indicates that project configuration settings relating to the interface are invalid or have not been specified.

4. If it is not required to export directly to a VPE Workbench 5.8 project, or if the project is a VPE Workbench 5.6 or 5.7 project, data can instead be loaded into the VPE Workbench project using facilities on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

These facilities enable users to "manually" copy the output files generated by the synchronisation procedure into the publishing area, from where they will automatically be imported into the VPE Workbench database. Data from multiple drawings may be transferred using this procedure.

5. If it is only required to transfer data to an SQL database, data is automatically transferred to the SQL database specified in the AVEVA P&ID Project Administration program during synchronisation.

6. The Export to P&ID Reports checkbox and the Export & Consolidate Databasecheckbox are only relevant to the Exporting Data to a P&ID Reports Databaseprocedure.

7. To enter a description or comments regarding this synchronisation process select the Add/Edit Description button. The Description dialog is then displayed:

12.18:192© 2011 AVEVA Solutions Ltd

Page 581: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Enter the required description and select the OK button.

Note: If a description is not entered before the synchronisation process is started, the Description dialog may be displayed automatically during the process depending on the project configuration (see above).

8. To initiate the synchronisation procedure, select the Synchronise button.

The progress of the procedure is displayed using a progress bar, and a count of the number of tasks successfully completed or failed.

While synchronisation is in progress the label of Synchronise button changes to Cancel. Select this button to abort the procedure.

9. If a description of the export was not entered before the synchronisation process was started (see above), the Description dialog may be displayed automatically during the process (depending on the project configuration). Enter a description as required and select the OK button.

10. Select the Details >> button to view further details. The Details pane is then displayed.

11. The Details pane consists of two tabs, Tasks and Details.

The Tasks tab displays the list of synchronisation tasks and the status of these tasks: Processing , Complete , Fail , or Pending.

12.18:193© 2011 AVEVA Solutions Ltd

Page 582: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

12. The Details tab displays processing details of each engineering item, i.e. error , warning and success messages.

13. If only error and warning messages are to be displayed, check the Show error and warning messages only checkbox.

14. Double-click on a message to select the item on the drawing. Any errors and warnings associated with the item can then be fixed. For details of errors and warning, and suggested solutions, see Error and Warning Messages.

Note: Error and warning messages are also added to the drawing. These can be deleted individually as required, or all them can be deleted at once using the Deleting Error Blocks procedure.

15. The Synchronise dialog box remains open so that further items can be selected and problems resolved.

16. A monitor file is generated by the synchronisation procedure, which lists the messages displayed in the Details tab. Select the View button to open this file in Notepad.

17. When synchronisation is complete the label of Cancel button changes to Close. Select this button to close dialog.

18. If NETOUTPUTBATCH was entered at the Command prompt, the synchronisation process is carried out but the he Synchronise dialog box is not displayed. The progress of the procedure is displayed at the Command prompt.

19. Whichever method is selected, a redraw may be required at the end of the process to remove the highlighting which appeared during the pipe validation.

12.18:194© 2011 AVEVA Solutions Ltd

Page 583: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Error and Warning Messages• Errors• Warnings

- Errors

ERROR: 144 Too many routes away from point

Problem:

A pipe component is connected to more than multiple components that could be valid routes for the pipe.

A valid pipe consists of a collection of in-line components and pipe segments that are graphically connected to each other from its source, represented by the start node symbol, to its destination, represented by the end node symbol. Each of the components must be connected to each other at their connections points and there must only be one possible graphical route from source to destination.

Solutions:

Check if the entity or connection point flag indicated by the error mark contains more than one possible valid route for a pipe. For instance, a pipe tee is detected where the other pipe has not been labelled.

Label the unlabelled pipe and try again.

Check for overlapping pipe segments.

Delete one of the pipe segments.

Check for pipe segments or pipe items belonging to different pipes that are too close to each other.

This error can also occur on rare occasions in extremely crowded drawings where it is not possible to distinguish whether the items are connected to each other or not.

Stretch the pipes away from each other as much as possible.

Try not to use symbols with very small lengths. For instance, double flanges. Try to keep symbol lengths to at least 2 millimetres minimum for metric projects, or 0.004 inches for imperial projects.

ERROR: 145 No routes away from point

Problem:

The synchronise routine cannot find a valid graphical route from the pipe source to the pipe destination.

A valid pipe consists of a collection of in-line components and pipe segments that are graphically connected to each other from its source, represented by the start node symbol, to its destination, represented by the end node symbol. Each of the components must be connected to each other at their connections points.

Solutions:

Check that all the components and pipe segments are connected to each other.

Edit the component to ensure it physically touches the other line components at their connection points.

12.18:195© 2011 AVEVA Solutions Ltd

Page 584: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Check that the angles of the start nodes (pipe source) and end nodes (pipe destination) coincide with the angles of the first elements connected to them.

Use rotate command to align the node with the connecting pipe elements.

ERROR: 153 Drawing Number missing from drawing - Validation Aborted

Problem:

The drawing has not been assigned a drawing name.

Solution:

Access the item Properties dialog and complete the drawing name field.

ERROR: 155 Reducer with NO Label

Problem:

The line reducer has not been assigned a tag.

Solution:

Access the item Properties dialog and complete the mandatory label fields.

Note that this error can be downgraded to a warning by unchecking the "Reducer not Labelled" Error-Balloon Placement checkbox on the Label Types Configuration Category of the AVEVA P&ID Project Administration program.

ERROR: 309 Amount of Typical data does not match owner

ERROR: 321 Amount of Typical data does not match connected pipe

ERROR: 396 Amount of typical Data does not match branch source or Destination

Problem:

The number of typical records allocated to an engineering item (equipment, valve, instrument, branch, on/off dialog connector or line fitting) does not match with the number of typical records allocated to the engineering items that are graphically connected to it.

Solution:

Check that the number of typical records allocated to the engineering items graphically connected to each other match, and correct is necessary.

ERROR: 332 Unable to connect to database

Problem:

The system cannot transfer the drawing data to the project database, because of a database connection problem.

Solutions:

Check that the target database is working.

Check that the database Middle tier is working.

Check that the network connection is working.

ERROR: 343 Duplicate instruments, fix drawing

Problem:

A duplicated instrument exists in the active drawing

12.18:196© 2011 AVEVA Solutions Ltd

Page 585: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Solution:

Find the pair of duplicated instrument and change the tag number of one of them. The Detail list can be use to search for the duplicate instrument tags. See 8.9.5: List Item Details.

ERROR: 398 Unable to transfer Data to Workbench, please contact system administrator

Problem:

The system is not able to transfer the data to the oracle database.

Solutions:

The Oracle Client might not be properly installed or configured on the client machine.

Ensure the Oracle client has been installed on the local machine

Oracle OLE DB drivers must also be installed from the official Oracle CD.

Oracle OLE DB drivers can be found on the Oracle 9i or Oracle 10g CD.

The Oracle version installed must be compatible with the target project database

The project database selected during the installation of AVEVA P&ID patch 14 must match that of target project database.

- Warnings

WARNING: 8 Nozzle without Label

Problem:

The nozzle has not been assigned a tag.

Solution:

Access the item Properties dialog and complete the mandatory label fields.

WARNING: 9 Nozzle without Size

Problem:

An equipment nozzle has not been sized.

Solution:

Access the item Properties dialog and complete the size field.

WARNING: 21 Pipe Flag with no labels

Problem:

An off dialog connector does not have a label.

Solution:

Access the item Properties dialog and add a label to the off dialog connector.

WARNING: 35 Branch id NOT assigned for item

Problem:

The system cannot find the owner pipe of an engineering item, such as a valve or an instrument measurement balloon.

12.18:197© 2011 AVEVA Solutions Ltd

Page 586: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Solutions:

Make sure the item is graphically connected to the pipe network via a process link.

If item is connected to a vessel, use trim pipes to link the item to the trim pipe data.

Avoid complicated arrangements with process links whenever possible. Try using tagged pipes instead.

WARNING: 51 Reducer has no label. Downstream item sizes will be affected

Problem:

The line reducer has not been assigned a tag.

Solution:

Access the item Properties dialog and complete the mandatory label fields.

Note that this warning can be upgraded to a warning by checking the "Reducer not Labelled" Error-Balloon Placement checkbox on the Label Types Configuration Category of the AVEVA P&ID Project Administration program.

WARNING: 74 Port without Size

Problem:

A valve port has not been assigned a tag.

Solution:

Access the item Properties dialog and complete the mandatory label fields.

WARNING: 78 Reducer Label Associated to the wrong Label set

Problem:

The wrong pipe label set has been selected to label a reducer.

Solution:

Delete the reducer.

Select the correct pipe segment size to retain when prompted.

Insert the reducer symbol again. This time select the nearest label upstream of the reducer from the correct pipe label set. If there are no upstream labels, then the pipe start node should be selected instead.

WARNING 80: Could not validate TEE connection, Fix drawing

Problem:

The lengths of one or more pipe segments connected to a TEE are too small.

Solutions:

Join any pipe segment that is too small to the contiguous one that belongs to the same branch.

If it is an extremely crowded drawing, try stretching the TEE one snap away from its position.

WARNING: 82 Size mismatch at Joint

Problem:

Two joined branches are different sizes at the join.

12.18:198© 2011 AVEVA Solutions Ltd

Page 587: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Solution:

Change the size of one of the branches to match the other using the Properties dialog of the appropriate reducer or pipe segment.

WARNING: 83 Equipment item without tag letters

Problem:

The equipment has not been assigned a tag, or tag includes the null project character.

Solution:

Access the item Properties dialog and complete the mandatory label fields.

WARNING: 84 Nozzle connection size mismatch

Problem:

A nozzle is connected to a pipe which has a different size at the connection point

Solution:

Change the size either of the pipe or the nozzle, whichever is applicable, or delete the nozzle size label. The unlabelled nozzle will then automatically inherit its size from the connected pipe.

8.8.6 Synchronising Multiple Drawing Data with VPE Workbench

• Description This procedure is used to generate output files from a batch of drawings, which can subsequently be transferred to a batch of drawings.

The transfer itself is carried out using facilities on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions 1. Start the procedure by creating the SaveToModel.bat batch file. Running this file

initiates the synchronisation procedure for all the drawings in the folder specified in the batch file.

The batch file is generated using the "MakeSaveToModelBatch" routine. 2. Before running the routine some editing may be required to the "UserStartUp" routine.

If the second method listed below is used to generate the batch file, the "MakeSaveToModelBatch" routine may also require editing. For details, see 2.9.9: Running AVEVA P&ID in "Save To Model Mode".

3. Create the batch file by either: • selecting the Make Synch Batch File option in AVEVA Integration Group of the

Data Management Tab, or • running the "MakeSaveToModelBatch" routine from the VBA Editor.

12.18:199© 2011 AVEVA Solutions Ltd

Page 588: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. If the first method is selected, the Browse for Folder dialog is then displayed.

Select the folder in which the drawings that data is to be exported from are located. Select OK.

5. If the second method is selected, the batch file is generated using the settings specified by editing the "MakeSaveToModelBatch" routine, as described above.

6. The batch file can then run using standard Windows facilities, e.g. from Windows Explorer.

The synchronisation procedure is then carried out for all the drawings in the folder specified in the batch file. For further details see 8.8.5: Synchronising Data with a VPE Workbench Database.

7. After the routine ends the batch file will be automatically deleted. 8. The output files generated by the routine can be transferred a VPE Workbench

Database using facilities on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

8.8.7 Connecting to a VPE Workbench Database

• Description This procedure is used to connect to a VPE Workbench project database. Once connected to the database, data can be transferred to VPE Workbench using the facilities on the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program, or placed on the drawing using Labelling with VPE Workbench Data and Exporting Data to ISO 15926 Files procedures

For details of the use of this procedure in the context of drawing P&IDs, see 6.16: Dynamic Labelling.

See also 7.5: Exporting Data to a VPE Workbench Database.

12.18:200© 2011 AVEVA Solutions Ltd

Page 589: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by either:

• selecting VPE Logon from the drawing shortcut menu of the Engineering Explorer, or

• selecting the Login option in AVEVA Integration Group of the Data Management Tab.

2. The VPE Workbench Login dialog box is then displayed:

Complete the Username and Password fields, and select the required project from the drop-down list in the Project field.

Click OK. 3. The command ends automatically.

8.8.8 Disconnecting from a VPE Workbench Database

• Description This procedure is used to disconnect from a VPE Workbench project database.

For details of the use of this procedure in the context of drawing P&IDs, see 6.16: Dynamic Labelling.

See also 7.5: Exporting Data to a VPE Workbench Database.

• Instructions 1. Start the procedure by either:

• selecting VPE Logoff from the drawing shortcut menu of the Engineering Explorer, or

• selecting the Logout option in AVEVA Integration Group of the Data Management Tab.

12.18:201© 2011 AVEVA Solutions Ltd

Page 590: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.8.9 Labelling with VPE Workbench Data

• Description This procedure is used to label equipment, instruments and lines with detail data from a VPE Workbench project database. These labels can subsequently be automatically updated with current VPE Workbench data, or manually using the Exporting Data to ISO 15926 Filesprocedure. An item must exist in VPE Workbench for it to be labelled in this way.

A connection to the VPE Workbench database in question must first be established by following the Connecting to a VPE Workbench Database procedure.

For details of the use of this procedure in the context of drawing P&IDs, see 6.16: Dynamic Labelling.

• Example

• Associated Project Configuration Options If VPE Workbench data is to be automatically refreshed whenever a connection to VPE Workbench is made, the Auto-Refresh VPE Workbench Data checkbox on the Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program must be checked.

• Instructions 1. Start the procedure by selecting the Properties option in AVEVA Integration Group of

the Data Management Tab.2. The Command prompt will then display:

Select Entity or Branch Label

Select the item that is be labelled with VPE Workbench data. In the case of equipment or instruments, select the body of the item itself. In the case of a line, select the label.

12.18:202© 2011 AVEVA Solutions Ltd

Page 591: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The Designator Form is then displayed:

This displays a list of relevant VPE Workbench detail data designators that may be placed on the drawing. Use the + boxes to expand the entries on the list to display the values associated with the designators.

By default, the dialog only displays those designators that have values defined against them. In order to have the dialog display all designators, check the Display All Designators checkbox. Designators without values display a placeholder in the value column, for example:

<INS Altitude value>

Where "INS" indicates the relevant entity type (in this example instrument) and "Altitude" is the designator name. Other entity types are EQU for equipment, PIP for piping and DWG for drawing.

4. Select VPE Workbench data to place on the drawing by checking the checkboxes adjacent to the designators and values or value placeholders. It is possible to add a value or value placeholder to a drawing without the associated designator, but a designator may not be placed without the associated value or value placeholder.

As required, select further items to label and repeat the process.

Click OK.

12.18:203© 2011 AVEVA Solutions Ltd

Page 592: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

5. The Command prompt will then display:

Indicate insertion point for VPE Workbench data field

Indicate the required position on the drawing for the first VPE Workbench data that was selected. Repeat for each selected VPE Workbench data.

The command then ends automatically.

• Viewing VPE Workbench Properties To view all the current VPE Workbench properties associated with an item labelled in this way, select the item and access the VPE Workbench dialog as described above. This enables a user to assess whether or not a refresh of the label data is required. Additional data may also be selected to label the item.

If a drawing number, placed on the drawing using the Adding a Title to a Drawing and entering Drawing Sheet Attributes, is associated with a VPE Workbench project, details of that project may be viewed using this method. The association between a P&ID drawing number label and Workbench project data takes place automatically.

8.8.10 Inserting Tables of VPE Workbench Data

• Description This procedure is used to insert tables on a drawing which are populated with data from a VPE Workbench project database. This data can be updated with current VPE Workbenchas described below.

A connection to the VPE Workbench database in question must be established before placing/refreshing the tables by following the by following the Connecting to a VPE Workbench Database procedure.

For details of the use of this procedure in the context of drawing P&IDs, see 6.16: Dynamic Labelling.

• Example

12.18:204© 2011 AVEVA Solutions Ltd

Page 593: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration Options • The appearance, position and content of tables are defined using the VPE Workbench

- Tables Sub-Set of the AVEVA P&ID Project Administration program. • If VPE Workbench data is to be automatically refreshed whenever a connection to VPE

Workbench is made, the Auto-Refresh VPE Workbench Data checkbox on the Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program must be checked.

• Instructions 1. Start the procedure by selecting the Insert Tables option in AVEVA Integration Group

of the Data Management Tab.2. All tables defined in the Administration program are then placed on the drawing in the

specified positions. They may then be repositioned if necessary.

If any of the tables are not required on the drawing, they may be deleted.

• Refreshing Table Data To manually refresh table data with current data from VPE Workbench, select the Insert Tables option as described above. All table data is then refreshed. Also, any new tables defined in the Administration program since the last occasion that tables were inserted or refreshed are placed on the drawing.

Tables that have been moved or deleted will reappear in the positions specified by the Administration program when table data is refreshed.

8.8.11 Refreshing VPE Workbench Data

• Description This procedure is used to manually refresh VPE Workbench data displayed on the drawing, with the latest data from the project database. Before this procedure is initiated, a connection with the database must be established using the Connecting to a VPE Workbench Database procedure.

For details of the use of this procedure in the context of drawing P&IDs, see 6.16: Dynamic Labelling.

• Associated Project Configuration Options If VPE Workbench data is to be manually refreshed using this procedure, rather then automatically refreshed whenever a connection to VPE Workbench is made, the Auto-Refresh VPE Workbench Data checkbox on the Miscellaneous - Settings Sub-Set of the AVEVA P&ID Project Administration program must not be checked.

• Instructions 1. Start the procedure by selecting the Refresh option in AVEVA Integration Group of the

Data Management Tab.2. Data that has been changed in the project database since it was placed or last

refreshed on the drawing is then refreshed.

Where value placeholders were placed on a drawing for designators without defined values, these placeholders are replaced if values have since been entered against those designators in the database.

12.18:205© 2011 AVEVA Solutions Ltd

Page 594: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The command then ends automatically.

8.8.12 Transferring Data from AVEVA Instrumentation and AVEVA Electrical

• DescriptionThis procedure is used to transfer instrument and electrical equipment data from AVEVA Instrumentation and AVEVA Electrical by placing instruments from AVEVA Instrumentation and electrical equipment from AVEVA Electrical onto project drawings.

For further information see 7.2: Transferring Data to and from AVEVA Instrumentation and AVEVA Electrical.

• Associated Project Configuration Options • Whether or not the AVEVA Instrumentation and AVEVA Electrical nodes in the P&ID

Data Grid are displayed is controlled on the AI Integration Configuration Category and the AE Integration Configuration Category of the AVEVA P&ID Project Administration program.

• If required, one of the AVEVA P&ID tag fields of transferred instrument and equipment may be automatically populated with the Area properties of the items in AVEVA Instrumentation or AVEVA Electrical. The tag fields are selected using the Derive Instrument AREA From and the Derive Equipment AREA From fields on the AI Integration Configuration Category and the AE Integration Configuration Category.

• Instructions1. Start the procedure by opening the P&ID Data Grid and logging on to the required

AVEVA Instrumentation or AVEVA Electrical project. See P&ID Data Grid - 4.5.5: Viewing and Assigning AVEVA Instrumentation and AVEVA Electrical Data for details.

2. Under the AVEVA Instrumentation node in the P&ID Data Grid, the Unassigned Instruments node lists each instrument type. Under the AVEVA Electrical node in the P&ID Data Grid, the Unassigned Electrical Equipment node lists each electrical equipment type. Select an instrument or electrical equipment type. Details of each item of the selected type in the AVEVA Instrumentation or AVEVA Electrical project that has not been added to a drawing in the AVEVA P&ID project are then displayed in the grid in the right-hand window.

12.18:206© 2011 AVEVA Solutions Ltd

Page 595: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. From the grid, select the item to be assigned and drag and drop it into the drawing window.

4. The Symbol List dialog is then displayed.

Select the AVEVA P&ID symbol type for theinstrument or electrical equipment and click OK.

5. A 'ghosted' image of the selected instrument or electrical equipment symbol appears on the crosshairs and the Command prompt will then display:

Insertion point:

Place the symbol on the drawing as required.

12.18:207© 2011 AVEVA Solutions Ltd

Page 596: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

6. The item is moved from the Unassigned Instruments or Unassigned Electrical Equipment list in the P&ID Data Grid to the Assigned Instruments or Assigned Electrical Equipment list.

Imported instruments are added to the UNNAMED node in the Instrument Loops section of the Engineering Explorer.

8.8.13 Transferring Data to PDMS Schematic Databases

• DescriptionThis procedure is used to transfer data from an AVEVA P&ID drawing into a PDMS Schematic database. Data from the current drawing is transferred.

For further information see 7.3: Exporting to PDMS Schematic Databases.

Note: Data can also be exported from single or multiple drawings to XML files in ISO 15928 format. This data can subsequently be imported into a Schematic database using the AVEVA PDMS or AVEVA Marine Schematic Model Manager module. See 8.8.15: Exporting Data to ISO 15926 Files.

• Associated Project Configuration OptionsWhether or not the AVEVA Schematic Database node in the P&ID Data Grid is displayed is controlled on the PDMS Integration Configuration Category of the AVEVA P&ID Project Administration program.

The installation of PDMS that the AVEVA P&ID project is integrated with is also selected on the PDMS Integration Configuration Category.

• Instructions1. Start the procedure by opening the P&ID Data Grid and logging on to the required

PDMS Schematic database See P&ID Data Grid - Viewing and Exporting to a PDMS Schematic Database for details.

2. Start the data transfer by either:• selecting the Save Work option in AVEVA Integration Group of the Data

Management Tab, or • right-clicking on the AVEVA Schematic Database node in the P&ID Data Grid and

selecting the Save Work option from the menu that is then displayed.

12.18:208© 2011 AVEVA Solutions Ltd

Page 597: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

3. The Save Work Progress dialog is then displayed and the transfer of data started.

The progress of the transfer procedure is displayed in the Save Work Progress bar.

Details of the transfer are displayed in the Summary tab.

If the transfer is completed with errors or warnings, a message informing the user of this is displayed at the bottom of the dialog. Details of errors and warnings are displayed on the Errors tab.

To open a log file of the transfer summary and the errors/warnings, select the Viewbutton.

To hide the Summary and Errors tabs, select the Details button. Select the button again to display them again.

8.8.14 Publishing Data to AVEVA NET

• DescriptionThis procedure is used to export data from a drawing into files that can subsequently be imported into AVEVA NET Portal.

Note: Facilities to export data from multiple drawings, and to export drawing data a remote AVEVA NET server are available in the AVEVA NET - Advanced Options Sub-Set of the AVEVA P&ID Project Administration program.

For further information see 7.6: Exporting Data to AVEVA NET.

12.18:209© 2011 AVEVA Solutions Ltd

Page 598: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Associated Project Configuration OptionsThe export is configured using the AVEVA NET - Configurations Sub-Set, AVEVA NET - Mappings Sub-Set and AVEVA NET - Setting Sub-Set of the AVEVA P&ID Project Administration program.

• Instructions1. Start the procedure by selecting the Publish to AVEVA NET option in AVEVA

Integration Group of the Data Management Tab.2. The export then takes place and the drawing data is exported to the staging area

specified in the project configuration. A progress dialog is displayed:

3. When the export is complete, if a log file has been specified in the project configuration, a message is displayed:

Click on the link to view the log file.

8.8.15 Exporting Data to ISO 15926 Files

• Description This procedure is used to export data from drawings to XML files in ISO 15928 format. This data can subsequently be imported into a Schematic database using the AVEVA PDMS or AVEVA Marine Schematic Model Manager module.

Data can be exported from a single drawing or from multiple drawings.

Note: Data can also be exported to XML files in ISO 15928 format using the AVEVA P&ID Upgrade Utility. See 2.1: Upgrading Pipes and Symbols from old Projects for details.

Note: Data can also be exported directly from a single drawing into a PDMS Schematic database. See 8.8.13: Transferring Data to PDMS Schematic Databases.

• Associated Project Configuration Options The folder into which the XML files and export log files are placed is specified in the VPE Data Path field of the Project Configuration Category of the AVEVA P&ID Project Administration program.

12.18:210© 2011 AVEVA Solutions Ltd

Page 599: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

The default folder from which drawings are selected is specified in the Save Path field of the Project Configuration Category.

The XML schema used, and the appearance of the SVG files used to display drawings in P&ID Manager/PDMS, are specified using user defined directives set up in the User Defined Directives section of the Miscellaneous - Settings Sub-Set.

• Instructions • Exporting from a Single Drawing• Exporting from Multiple Drawings

- Exporting from a Single Drawing

1. Start the procedure by selecting the ISO 15926 option in AVEVA Integration Group of the Data Management Tab.

2. The export will then take place. The progress of the export will be indicated in a progress bar at the bottom of the application window.

3. A log file displaying details of the export, including any error and warnings, is then automatically displayed in Notepad.

The exported XML file and the log file are located in the VPE Data Path field (see Associated Project Configuration Options above).

- Exporting from Multiple Drawings

1. Start the procedure by selecting the ISO 15926 Batch option in AVEVA Integration Group of the Data Management Tab.

2. The Browse For Folder dialog is then displayed:

Select the folder in which the drawings are located. By default, the drawing save folder is selected. Note that if this has not been specified in the AVEVA P&ID Project Administration program (see above), the batch import will not function.

12.18:211© 2011 AVEVA Solutions Ltd

Page 600: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Data will be exported from all drawings in the selected folder.3. Press the OK button.

The export will then take place. The progress of the export will be indicated in a progress bar at the bottom of the application window, and in the command prompt, for example:

1 of 7 905675.dwg Drawing file exported successfully

2 of 7 905676.dwg Drawing file exported successfully

4. When the export is complete, a message is displayed (for example):

The exported XML files and the export log files are located in the VPE Data Path field (see Associated Project Configuration Options above).

8.8.16 Exporting Data to Excel

• Description This procedure is used to export item and drawing data to Microsoft Excel spreadsheets. The data can then be edited in the spreadsheet and imported back into AVEVA P&ID using separate procedures. See 8.8.17: Editing P&ID Data in an Excel Spreadsheet and 8.8.18: Importing Data from Excel.

Data can be exported from a single drawing or from a batch of drawings. A spreadsheet is generated for each drawing that data is exported from.

For more details on the use of this procedure, see 7.8: Transferring Data to and from Excel.

• Associated Project Configuration Options Exported items can either be grouped by item types or item groups on the spreadsheet. This setting is made on the Excel Interface Configuration Category pane of the AVEVA P&IDProject Administration program.

The default item type filter, i.e. the default list of type of items for which data is to be exported, as also set on the Excel Interface Configuration Category pane. A different set of type of item to be exported can be selected for an export if required (see below).

• Instructions• Filtering the Export• Exporting from a Single Drawing

12.18:212© 2011 AVEVA Solutions Ltd

Page 601: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Exporting from Multiple Drawings

- Filtering the Export

The default item type filter for exports, i.e. the default list of type of items for which data is to be exported, is set on the Excel Interface Configuration Category of the AVEVA P&ID Project Administration program.

To specify a different set of item types to be exported for an individual export, select the Excel Filter option in Import/Export Group of the Data Management Tab

The Excel Filter menu is then displayed:

It initially displays the default filter settings as set up in the Administration program. Change the filter settings for subsequent exports during the current session by checking and unchecking the checkboxes as required.

- Exporting from a Single Drawing

1. Start the procedure selecting the Excel Export option in Import/Export Group of the Data Management Tab.

2. A spreadsheet is then generated with the same name as the drawing, in the following location:

C:\AVEVA\P&ID\PROJECT\name of project\Vantage\name of the drawing.xls

Note: The spreadsheet will overwrite a previous spreadsheet exported from the drawing.

The spreadsheet can then be edited using the Editing P&ID Data in an Excel Spreadsheet procedure.

For details of the layout and contents of the spreadsheet, see 9.7: Format of the Excel Interface Spreadsheet.

- Exporting from Multiple Drawings

This procedure is used to generate a spreadsheet for every drawing in a selected folder by creating and running a batch file.

1. Start the procedure by selecting the Make Excel Export Batch File option in Import/Export Group of the Data Management Tab.

12.18:213© 2011 AVEVA Solutions Ltd

Page 602: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. The Browse for Folder dialog is then displayed.

Select the folder in which the drawings that data is to be exported from are located. Select OK.

3. The batch file is then created in the same folder as the folder containing the selected drawings:

4. The batch file can then run using standard Windows facilities, e.g. from Windows Explorer. All the AutoCAD sessions must be closed when running the batch file.

5. Spreadsheets are then generated with the same names as the drawings, in the following location:

C:\AVEVA\P&ID\PROJECT\name of project\Vantage

Note: The spreadsheets will overwrite a previous spreadsheets exported from the drawings.

12.18:214© 2011 AVEVA Solutions Ltd

Page 603: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Spreadsheets can then be edited using the Editing P&ID Data in an Excel Spreadsheetprocedure.

For details of the layout and contents of the spreadsheets, see 9.7: Format of the Excel Interface Spreadsheet.

8.8.17 Editing P&ID Data in an Excel Spreadsheet

• Description This procedure used to:

• edit data exported from AVEVA P&ID to a spreadsheet (see 8.8.16: Exporting Data to Excel)

• after this data has been imported back into AVEVA P&ID (see 8.8.18: Importing Data from Excel), correct any errors such as invalid values detected in the spreadsheet before re-importing.

For more details on the use of this procedure, see 7.8: Transferring Data to and from Excel.

• Associated Project Configuration Options • The lists of valid values against which imported item values are checked are stored in

the location specified Project Configuration Category of the AVEVA P&ID Project Administration program.

• The valid values themselves are set up using the List of Values Configuration Categorypane.

• For each item group, e.g. drawing attributes, equipment, pipes etc, the column that data is imported from, i.e. NEW or not, is selected on the Excel Interface Configuration Category of the AVEVA P&ID Project Administration program.

• Instructions1. Start the procedure selecting the Excel Open option in Import/Export Group of the

Data Management Tab.

The spreadsheet containing the exported drawing data will then open.

For details of the layout and contents of the spreadsheet, see 9.7: Format of the Excel Interface Spreadsheet.

2. Edit details of items and the drawing as required. This can be done in two ways:• Editing the existing values in the spreadsheet.• Each column containing values that can be edited has a corresponding NEW

column in which new values can be entered. For example, in a worksheet containing a TAG column, there will also be a NEW TAG column.

The NEW fields are provided to enable users to compare the original attributes with the modified ones. Which columns are to be used for each item group is set by project configuration (see above).

• Points to Note when Editing Data:• The following fields are validated:

• Area • Line size in imperial units• Line size in metric units

12.18:215© 2011 AVEVA Solutions Ltd

Page 604: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Insulation index• Insulation condition• Insulation table• Paint Code• Fluid Service • Specification• Tracing number• Tracing size• Tracing type• Instrument type• Action when valve fail • Valve code

During the import process, validated fields are checked against lists of valid values set up using the AVEVA P&ID Project Administration program. They must not be left blank.

• Some fields are insertable, others are only updateable (assuming they are not read-only). Updateable fields can only be amended in a spreadsheet. In other words, if they do not already exist on a drawing (and therefore can be exported to a spreadsheet), they can only be changed in a spreadsheet, not added.

• Insertable fields are label fields that can be added as new labels for items. When the spreadsheet is imported, these new labels will be place on the drawing. Columns in which insertable labels can entered can be identified on a spreadsheet as the subsequent columns will columns used to add the offset and rotation properties of any new labels. For example:

• If offset values for labels are not entered for new labels, the labels will be placed directly on top of the items they are labelling.

• If offset values for labels are not entered for valve and inline fitting labels, the labels will be placed directly on top of the items they are labelling.

• If an item group is set by project configuration to import from the NEW columns, all validated NEW fields for that item group must be populated. If any validated NEW fields are left blank, these will be regarded as invalid by the import process as they do not contain valid values.

• NEW fields can quickly be populated by copying and pasting values from columns containing current values.

• The Tracing No, Tracing Size, Tracing Type, Insulation Tab, Insulation Ind, Insulation Con and Paint Code values of Pipes are validated and therefore should not be left blank. However, <none> is a valid value, signifying that no value has been set for these attributes.

• Fields of attributes that are not validated may be left blank if not value has been assigned to these attributes.

• If an off-sheet connector or drawing data attribute is changed to an empty field, this will result in an error on import, i.e. the row in question will be flagged as invalid.

• The drawing number of the P&ID can only be changed by editing using the Drawing Data worksheet. Changes to the drawing number made on other worksheets will be ignored by the import.

12.18:216© 2011 AVEVA Solutions Ltd

Page 605: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Although the spreadsheets include columns for both the upstream and the downstream size values of reducers, only changes made to the downstream values will result in changes to the drawing. Changes made to upstream values will be ignored.

• Values in the HANDLE columns must NOT be edited. If handles are edited, this will result in an error on import.

• During the import process, the tags of items will be checked to ensure that they correspond to the formatting and uniqueness rules set up using the Pipes Configuration Category, Instruments Configuration Category, Equipment Configuration Category, Valves Configuration Category and Miscellaneous Configuration Category of the AVEVA P&ID Project Administration program.

• The performance of the import procedure can be improved by deleting worksheets that do not contain changes.

• After the import has taken place, rows in the spreadsheet containing errors are displayed in red, and are not imported. In this example, the value in the SIZE field of the first item row is invalid:

• During the import:, any errors and inconsistencies are written to a file, ErrorLog.html, in the following location:

C:\AVEVA\P&ID\PROJECT\name of project\Vantage\

12.18:217© 2011 AVEVA Solutions Ltd

Page 606: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

For example:

The file can be opened by double-clicking on a row in the spreadsheet containing an error.

• Rows in the spreadsheet containing valid changes displayed in green:

8.8.18 Importing Data from Excel

• Description This procedure is used to import item and drawing data from Microsoft Excel spreadsheets. This data is exported to the spreadsheet and edited using separate procedures. See 8.8.16: Exporting Data to Excel and 8.8.17: Editing P&ID Data in an Excel Spreadsheet.

Data can be imported into a single drawing or into a batch of drawings from which data was previously exported to a spreadsheet.

12.18:218© 2011 AVEVA Solutions Ltd

Page 607: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

Note: Once an import is complete, the drawing must be refreshed in order to be updated by the imported data. See 8.9.2: Regenerating the Drawing.

For more details on the use of this procedure, see 7.8: Transferring Data to and from Excel.

• Associated Project Configuration Options • For each item group, e.g. drawing attributes, equipment, pipes etc, the column that

data is imported from, i.e. NEW or not, is selected on the Excel Interface Configuration Category of the AVEVA P&ID Project Administration program.

• The lists of valid values against which imported item values are checked are stored in the location specified Project Configuration Category.

• The valid values themselves are set up using the List of Values Configuration Category.

• Instructions• Importing to a Single Drawing• Importing to Multiple Drawings

- Importing to a Single Drawing

1. Start the procedure selecting the Excel Import option in Import/Export Group of the Data Management Tab.

2. The data is validated on import against the valid values set up for the project using the Project Administration program. Any errors and inconsistencies are written to a file, ErrorLog.html, in the following location:

C:\AVEVA\P&ID\PROJECT\name of project\Vantage\

12.18:219© 2011 AVEVA Solutions Ltd

Page 608: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

For example:

Rows in the spreadsheet containing valid changes displayed in green. Rows in the spreadsheet containing errors are displayed in red.

Data in rows containing errors is not imported. To correct errors, use the Editing P&ID Data in an Excel Spreadsheet procedure, and carry out the import procedure again to import the corrected data.

For details of the layout and contents of the spreadsheet, see 9.7: Format of the Excel Interface Spreadsheet.

- Importing to Multiple Drawings

This procedure is used to import data into every drawing in a selected folder (from which data has previously been exported to a spreadsheet) by creating and running a batch file.

1. Start the procedure by selecting the Make Excel Import Batch File option in Import/Export Group of the Data Management Tab.

12.18:220© 2011 AVEVA Solutions Ltd

Page 609: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. The Excelin Batch File Parameters dialog is then displayed:

Select the location of the AutoCAD installation, the location of the configuration file and the required AutoCAD profile, and select OK.

3. The Browse for Folder dialog is then displayed.

Select the folder in which the drawings that data is to be imported into are located. Select OK.

12.18:221© 2011 AVEVA Solutions Ltd

Page 610: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

4. The batch file is then created in the same folder as the folder containing the selected drawings:

5. The batch file can then run using standard Windows facilities, e.g. from Windows Explorer. All the AutoCAD sessions must be closed when running the batch file.

6. The data is validated on import against the valid values set up for the project using the Project Administration program. Any errors and inconsistencies are written to a file, ErrorLog.html, in the following location:

C:\AVEVA\P&ID\PROJECT\name of project\Vantage

12.18:222© 2011 AVEVA Solutions Ltd

Page 611: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

For example:

Rows in spreadsheets containing valid changes displayed in green. Rows in spreadsheets containing errors are displayed in red.

Data in rows containing errors is not imported. To correct errors, use the Editing P&ID Data in an Excel Spreadsheet procedure, and carry out the import procedure again to import the corrected data.

For details of the layout and contents of the spreadsheets, see 9.7: Format of the Excel Interface Spreadsheet.

8.8.19 Exporting Symbols

• DescriptionThis procedure is used to export the symbols on a drawing. It copies all the symbols on a drawing to the ExportSymbols folder of the project. From there they may be edited, or manually copied elsewhere, e.g. to another project.

• Instructions1. Start the procedure by selecting the Upgrade Utility Commands > Export Symbols

option from The Drawing Page shortcut menu or by selecting the Export Symbols option in Non-Intelligent Entities Upgrade Group of the Utilities Tab.

12.18:223© 2011 AVEVA Solutions Ltd

Page 612: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

2. The Symbol List dialog is then displayed:

The dialog lists all the symbols on the drawing.

To select a symbol for export, check its Include checkbox. To check all Include checkboxes, select the Select All button. The Select All button then changes to the UnSelect All button, used to uncheck all Include checkboxes.

3. Once all required symbols have been selected for export, select the Process button. The selected symbols are then exported.

12.18:224© 2011 AVEVA Solutions Ltd

Page 613: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

They are processed one at a time. A dialog is opened which displays each symbol as it is processed:

4. Once the process is converted, a message displays the number of symbols successfully export.

The selected symbols are copied to ExportSymbols folder of the project, as displayed in the message. They can be viewed by clicking on this folder in the Symbol Explorer.

12.18:225© 2011 AVEVA Solutions Ltd

Page 614: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8.9 Utilities

8.9.1 Creating Assemblies

• Description This procedure is used to group to together drawing objects to create assemblies.

Three types of assembly may be created:• Graphical Assemblies - pipes and symbols collected together into an AutoCAD block to

act as templates, retaining the item associations• Design Data Templates - collections of VPE Workbench or P&ID Data Grid designators

and values used to label items. • Annotation Assemblies - there are two sub-types of Annotation Assemblies:

• Pipe: collections of pipe labels and symbols used to annotate pipes• UDA: collections of user-defined attribute labels and symbols used to annotate

pipes, instruments and equipment.

Existing assemblies may only be removed by the AVEVA P&ID administrator.

For details of the use of this procedure in the context of drawing P&IDs, see and 6.14: Assemblies.

• Example

• Errors To prevent redefinitions that may have project wide implications, users cannot redefine existing blocks. Only an administrator may do this. If a user attempts this, an error message is displayed.

12.18:226© 2011 AVEVA Solutions Ltd

Page 615: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by selecting the Assembly option in Symbol Group of the Home

Tab. 2. The following option is then displayed:

Select either DDT (for Design Data Templates), GRA (for Graphical Assemblies) or ANN (for Annotation Assemblies) as required.

3. If ANN was selected, the following is then displayed:

Select either Pipe or UDA, depending on the type of Annotation Assembly required.4. If UDA was selected, the following is then displayed:

Select the category of item which the UDA assembly will be used to annotate.5. Once the assembly type is selected, the Command prompt will then display:

Select objects to create assembly (Select using Crossing[C], Crossing Polygon[CP]:

Graphically select entities (including any required labels or designators) using the selection methods listed at the prompt.

6. The Command prompt will then display:

Pick a base point: :

Pick a logical insertion point.

12.18:227© 2011 AVEVA Solutions Ltd

Page 616: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

7. The Command prompt will then display (for example):

Specify the Assembly name:

Enter the name of the assembly and press Enter.8. The Command prompt will then display (for example):

Specify the Assembly description:

Enter a description of the assembly and press Enter. The assembly is then created.

As users cannot delete assemblies, they must be properly managed on a project. All assembly names and descriptions should be logical and follow any conventions already in use.

The assembly is added to the Assemblies symbol folder of the project. There is a sub-folder for each assembly type. In addition, the Annotation Assembly sub-folder contains sub-folders for each Annotation Assembly sub-type, and the UDA sub-type folder contains further sub-folders for each type of UDA assembly.

Note: The Assemblies folder in the Symbol Explorer or the appropriate assembly type sub-folder, must be refreshed before a new assembly will appear in the Symbol Explorer.

Note: This procedure differs from the AutoCAD block command in that the entities selected to form an assembly remain on the drawing after the assembly has been created.

Assemblies are inserted in the same way as other symbols. See 8.4.11: Inserting Assemblies.

8.9.2 Regenerating the Drawing

• Description This procedure is used to "redraw" the drawing in order to remove unwanted highlighting, which may occasionally persist on a drawing longer then it is required.

• Instructions 1. Start the procedure by either:

• selecting Regen from The Drawing Page menu of the drawing, or • selecting Refresh from the Engineering Explorer menu of the drawing.

2. The drawing is then redrawn and all unwanted highlighting is removed.

8.9.3 Creating Item Associations

• Description This procedure is primarily used to associate I/O rockets with instruments. It can also be used re-create associations between nozzles, conditioners or instrument handwheels should they be lost.

12.18:228© 2011 AVEVA Solutions Ltd

Page 617: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by entering ASASSOC at the Command prompt. 2. The Command prompt will display:

Select Nozzle, Conditioner or Instrument Handwheel for association with owner

Pick the item to be associated, e.g., nozzle. 3. The Command prompt will then display:

Indicate Equipment item for association:

Pick the item to be associated, e.g. vessel.

Both items "flash" to show that association has taken place. 4. The Command prompt will then display:

Select Nozzle, Conditioner or Instrument Handwheel for association with owner:

Select another item if required or press Enter to execute the command.

8.9.4 Show Associations between Items

• Description This procedure is used to show the association between items, for example, between a vessel and its nozzles.

For details of the use of this procedure in the context of drawing P&IDs, see 6.5: Inserting Symbols and 6.8: Drawing Pipes and Connections.

12.18:229© 2011 AVEVA Solutions Ltd

Page 618: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Example

• Instructions 1. Start the procedure by selecting the Show Object Association option in Properties

Group of the Home Tab. 2. The Command prompt will display:

Select Item:

Pick an item. 3. All associated items are then highlighted, and the Command prompt will then display,

for example:

Number of Associated Objects - 12, Hit <Return> to continue:

In this example there are 12 items associated with the selected item.

Press Enter to end the command.

8.9.5 List Item Details

• Description This procedure is used when validating a drawing to check information regarding a selected item, e.g., its sequence ID, item type, owning pipe etc.

For details of the use of this procedure in the context of drawing P&IDs, see 6.11.4: Labelling Pipes with Reducers and Reducing Valves and 6.10.4: Label Inheritance from Owning Pipes.

Note: The sequence IDs of all entities in a pipe can be viewed and if necessary edited using the Viewing and Editing Pipe Entity Sequences procedure.

12.18:230© 2011 AVEVA Solutions Ltd

Page 619: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by selecting the List AVEVA P&ID attributes option in Properties

Group of the Home Tab2. The Command prompt will display:

Select entity:

Pick the item, e.g. a pipe. 3. The Command prompt will then display something similar to this:

*Item Handle: 8DC

*Registered application name: AVEVA P&ID-07058MU04269U42VFK7

*Code 1000, ASCII string: PSU

The ASCII string PSU shown above is the item type. 4. If a pipe label is picked, Sequence ID information will be displayed:

*Code 1070, Branch id: 2

*Code 1070, Sequence id: 1

5. If a start node is picked, the following type of information about that pipe or line will be displayed:

Item Handle: 1B9B

*Registered application name: AVEVA P&ID-07058MU04269U42VFK7

*Code 1000, ASCII string: PSN

* Code 1070, Branch Id: 17

* Code 1005, Associated Handle: 1B9C

* Code 1005, Associated Handle: 1B9D

* Code 1000, Pipe Label field 1: 1/2"

* Code 1000, Pipe Label field 2: SW

* Code 1000, Pipe Label field 3: 20

* Code 1000, Pipe Label field 4: 2323

* Code 1000, Pipe Label field 5: S1A

* Code 1000, Pipe Label field 6: <NONE>

* Code 1000, Pipe Label field 7: <NONE>

* Code 1000, Pipe Label field 8: <NONE>

* Code 1000, Pipe Label field 9: <NONE>

* Code 1000, Pipe Label field 10: <NONE>

12.18:231© 2011 AVEVA Solutions Ltd

Page 620: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

* Code 1000, Pipe Label field 11: <NONE>

* Code 1000, Pipe Label field 12: <NONE>

6. To identify the pipe that owns an item, carry out this procedure for an item. The owner is identified as follows:

*Code 1070, Branch id: 2

In this example, the owner of the item is the pipe with the branch id of 2.

If the branch id is not set, the item has no owner, and no attempt has been made to assign one. If the branch id is set to -1, an attempt has been made to graphically assign an owner to the item, but this has failed.

7. The command ends automatically.

8.9.6 Assigning a New Branch Id to a Pipe

• Description This procedure is used assign a new Branch Id to a pipe. This may be required if, during drawing validation or when data is being transferred to a database (see 8.8.5: Synchronising Data with a VPE Workbench Database), it is reported that there are pipes with duplicate Branch Id's.

Note: The Branch Id of a pipe can be viewed using the List Item Details procedure.

• Instructions 1. Start the procedure by selecting the Find Start Node using Branch Id option in

Project Configuration Group of the Utilities Tab.2. The Command prompt will display:

Please Select Pipe Start Node (PSN/BSN)

Select either the start or end node of the pipe in question. The pipe will then automatically be assigned a new, unique, Branch Id.

8.9.7 Viewing and Editing Pipe Entity Sequences

• Description This procedure is used to view the sequence of the entities that make up a pipe, and to change this sequence if required.

The procedure can also be used to add and remove entities to and from a pipe.

Note: The sequence number of individual entities in a pipe can be viewed using the List Item Details procedure.

12.18:232© 2011 AVEVA Solutions Ltd

Page 621: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

• Instructions 1. Start the procedure by selecting the Piping Sequence option in AVEVA Integration

Group of the Data Management Tab. 2. The Piping Sequence grid is then displayed:

3. Select any entity in a pipe. The sequence of entities in that pipe is then displayed in the grid:

4. The grid shows the entity type and handle of each entity in the selected pipe.5. The identity of the pipe and the total number of entities in it are displayed beneath the

grid.6. The Current Sequence column displays the current sequence number of each entity.7. If an entity is selected in the grid, it is highlighted in the drawing with a coloured box.

For example, the pipe segment below:

12.18:233© 2011 AVEVA Solutions Ltd

Page 622: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

8. The current highlight colour is displayed beneath the grid in the Highlight entity with:field. If required, a different highlight colour can be selected from the list accessible from the Highlight entity with: field.

9. To change the sequence of entities in the pipe, select the new sequence numbers in the Required Sequence column.

10. When the new sequence numbers have been selected, select the Update button, or right-click on the grid and select the Update option from the menu that is then displayed.

11. The changes are then implemented and grid is updated to reflect this.12. To add an entity to a pipe, right-click on the grid and select the Add Entity option from

the menu that is then displayed, then select the entity from the drawing. The selected entity is then added to the pipe and to the grid. The selected entity is added to the grid after the entity that was selected when the grid was right-clicked on. The added entity is allocated the sequence number of the selected entity plus one, and the sequence numbers of entities after the added entity are increased by one.

12.18:234© 2011 AVEVA Solutions Ltd

Page 623: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

13. To remove an entity from a pipe, right-click on the entity in the grid and select the Remove Entity option from the menu that is then displayed. The entity is then removed from the pipe and the grid. The sequence numbers of the remaining entities are updated to reflect this, i.e. the sequence numbers of entities after the removed entity are reduced by one.

8.9.8 Deleting Error Blocks

• DescriptionThis procedure is used to delete all error and warning messages from a drawing.

Various AVEVA P&ID procedures may result in error and warning messages being placed on a drawing, for example, the Synchronising Data with a VPE Workbench Databaseprocedure. The message blocks can be deleted individually as required, using the standard Deleting Drawing Objects procedure, or all of them can be deleted in one go using this procedure.

It is recommended that error and warning messages are not deleted until the problems they are referring to are resolved.

• Instructions1. Start the procedure by selecting the Delete Error Blocks option in AVEVA Integration

Group of the Data Management Tab. 2. All error and warning message blocks will then be deleted from the drawing.

8.9.9 Recovering Project Configuration Settings

• Description On occasion, changes to the project configuration may result is configuration conflicts when these changes are applied to a drawing. For example, if there are two layers or symbols with the same name. This will result in the drawing failing to load correctly.

Correct use of the AVEVA P&ID Project Administration Program should avoid such conflicts, but if they do occur, this procedure is used to remove these configuration conflicts and apply a fresh set of configuration data to the drawing.

• Instructions 1. Start the procedure by selecting the Recover Project Configuration option in Project

Configuration Group of the Utilities Tab2. The conflicts will then be resolved, and the drawing reloaded with a fresh set of

configuration data.

12.18:235© 2011 AVEVA Solutions Ltd

Page 624: aveva p&id

AVEVA P&ID 12.1 User GuideAVEVA P&ID Procedures

12.18:236© 2011 AVEVA Solutions Ltd

Page 625: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9 Appendices

9.1 AVEVA P&ID FilesThe majority of AVEVA P&ID setup and configuration files should be edited using the AVEVA P&ID Project Administration program. However, the following file must be edited directly using a standard text editor:

• 9.1.1: PID.MLN

9.1.1 PID.MLN Pipe styles may consist of multiple lines, as indicated by the definition of each pipe style, accessible from the List of Values pane of the AVEVA P&ID Project Administration program. The PID.MLN file, in the Install>AutoCAD>Bin directory, contains definitions of the style of multiple lines, for example the number of lines and the distances between them. Any line style that is defined as a multiple line must have its multiple line properties defined in the PID.MLN file.

By default, the PID.MLN file contains definitions of Standard, Main Pipe, Sub Pipe and Link styles. For each of these there separate entries for both metric and imperial measurements. Modify this file as required to edit the style of the existing multi-lines and to define the style of new ones.

For details on how to edit the PID.MLN file, refer to the appropriate AutoCAD documentation.

• PID.MLN File ExampleMLSTYLE

2

STANDARD

70

0

3

62

12.19:1© 2011 AVEVA Solutions Ltd

Page 626: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

256

51

90.00000000000000

52

90.00000000000000

71

2

49

0.5000000000000000

62

6

6

BYLAYER

49

-0.5000000000000000

62

6

6

BYLAYER

0

MLSTYLE

2

MULTI-MAIN

70

0

3

62

6

51

90.00000000000000

52

90.00000000000000

71

2

49

1.5000000000000000

62

6

6

BYLAYER

49

12.19:2© 2011 AVEVA Solutions Ltd

Page 627: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

-1.5000000000000000

62

6

6

BYLAYER

0

MLSTYLE

2

MULTI-SUBS

70

0

3

62

5

51

90.00000000000000

52

90.00000000000000

71

2

49

1.0000000000000000

62

5

6

BYLAYER

49

-1.0000000000000000

62

5

6

BYLAYER

0

MLSTYLE

2

MULTI-LINK

70

0

3

62

12.19:3© 2011 AVEVA Solutions Ltd

Page 628: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

7

51

90.00000000000000

52

90.00000000000000

71

2

49

0.5000000000000000

62

7

6

BYLAYER

49

-0.5000000000000000

62

7

6

BYLAYER

0

MLSTYLE

2

STDIMP

70

0

3

62

256

51

90.00000000000000

52

90.00000000000000

71

2

49

0.5000000000000000

62

6

6

BYLAYER

49

12.19:4© 2011 AVEVA Solutions Ltd

Page 629: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

-0.5000000000000000

62

6

6

BYLAYER

0

MLSTYLE

2

MULTI-MAIN-IMP

70

0

3

62

6

51

90.00000000000000

52

90.00000000000000

71

2

49

0.04000000000000000

62

6

6

BYLAYER

49

-0.04000000000000000

62

6

6

BYLAYER

0

MLSTYLE

2

MULTI-SUBS-IMP

70

0

3

62

12.19:5© 2011 AVEVA Solutions Ltd

Page 630: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

5

51

90.00000000000000

52

90.00000000000000

71

2

49

0.02000000000000000

62

5

6

BYLAYER

49

-0.02000000000000000

62

5

6

BYLAYER

0

MLSTYLE

2

MULTI-LINK-IMP

70

0

3

62

7

51

90.00000000000000

52

90.00000000000000

71

2

49

0.01000000000000000

62

7

6

BYLAYER

49

12.19:6© 2011 AVEVA Solutions Ltd

Page 631: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

-0.01000000000000000

62

7

6

BYLAYER

0

12.19:7© 2011 AVEVA Solutions Ltd

Page 632: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.2 Output File Format The AVEVA P&ID output file formats are detailed below.

Note: The file delimiter is the I character.

• Drawing Details - .drg file • Equipment Information - .equ file • Nozzle Information - .noz file • Instrument Loops - .ilp file• In-Line Non-Valves - .inv file • Process Connected Instrument Information - .ipc file • Remote Instrument Information - .irm file • In-Line Valves Information - .ivl file • System Output Information - .isy file • Pipe Information - .pip file • Pipe Item Information - .pit file • Notes Information - .nte file • Link Connectivities Information - .con file • User-Defined Attributes Information - .usd file • Valve Port Information - .por file • Monitor File - .mon file

9.2.1 Drawing Details - .drg fileProject number, char 32

Drawing number, char 32

Sheet number, char 10

Revision, char 32

Title[1], char 132

Title[2], char 132

Title[3], char 132

Title[4], char 132

Title[5], char 132

Client number, char 32

Des area, char 32

Line no1 min, char 32

Line no1 max, char 32

Line no1 used, char 32

Line no1 cancelled, char 32

Line no2 min, char 32

Line no2 max, char 32

12.19:8© 2011 AVEVA Solutions Ltd

Page 633: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Line no2 used, char 32

Line no2 cancelled, char 32

Line no3 min, char 32

Line no3 max, char 32

Line no3 used, char 32

Line no3 cancelled, char 32

Line no4 min, char 32

Line no4 max, char 32

Line no4 used, char 32

Line no4 cancelled, char 32

Loop no1 min, char 32

Loop no1 max, char 32

Loop no1 used, char 32

Loop no1 cancelled, char 32

Loop no2 min, char 32

Loop no2 max, char 32

Loop no2 used, char 32

Loop no2 cancelled, char 32

Output Counter, number 3

9.2.2 Equipment Information - .equ fileEquip handle, char 32

Owner handle (for electrical equipment items), char 32

Equip Block, char 16

Equip Function, char 16

Equip Prefix, char 16

Equip Letters, char 16

Equip Numbers, char 16

Equip Suffix, char 16

Description, char 80

AVEVA P&ID type (EQU,EQV or EQE), char 4

Grid reference, char 8

Interlock (y/n), char 4

Typical Item, char 4 ('*' if typical)

Symbol name (no character restriction)

12.19:9© 2011 AVEVA Solutions Ltd

Page 634: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.2.3 Nozzle Information - .noz fileNozzle handle, char 32

Nozzle label handle, char 32

Nozzle size handle, char 32

Equipment Owner handle, char 32

Nozzle label, char 32

Nozzle size, char 32

Description, char 80

Grid ref, char 8

Typical Item, char 4 ('*' if typical)

Connected Item Handle, char 32

Connected Item Type, char 4

9.2.4 Instrument Loops - .ilp fileHandle, char 32

Loop Number (Tag), char 16

Block, char 16

Function, char 16

Prefix, char 16

Type, char 16

Number, char 16

Suffix, char 16

9.2.5 In-Line Non-Valves - .inv fileInst handle, char 32

Label balloon handle, char 32

Link line handle, char 32

Prefix label handle, char 32

Letters label handle, char 32

Loop label handle, char 32

Suffix label handle, char 32

Panel ref prefix handle, char 32

Panel ref letters handle, char 32

Panel ref loop handle, char 32

Panel ref suffix handle, char 32

Symbol name, char 32

12.19:10© 2011 AVEVA Solutions Ltd

Page 635: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Prefix label, char 32

Letters label, char 32

Loop label, char 32

Suffix label, char 32

Panel ref prefix label, char 32

Panel ref letters label, char 32

Panel ref loop label, char 32

Panel ref suffix label, char 32

Descriptor label, char 80

Tag Description, char 80

Branch id, number

Sequence, number

Inlet Size, char 10

Outlet Size, char 10

Specification, char 10

Area, char 10

Paintcode, char 10

Insulation(Table), char 10

Insulation(Index), char 10

Insulation(Condition), char 10

Tracing (No of Tracers), char 10

Tracing (Size), char 10

Tracing (Type), char 10

Graphical tracing, char 10

AVEVA P&ID type, char 4

Symbol Description, char 80

Location, char 32

Signal Type connected, char 32

Grid ref, char 8

Units, char 4

PDMS type, char 4

PDMS Sub-type, char 4

Interlock (Y/N), char 4

Pattern Item, char 4 ('*' if pattern)

Panel Type, char 4 (I or E)

Typical Item, char 4 ('*' if typical)

12.19:11© 2011 AVEVA Solutions Ltd

Page 636: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.2.6 Process Connected Instrument Information - .ipc fileItem Handle, char 32

Prefix Handle, char 32

Type Handle, char 32

Loop Handle, char 32

Suffix Handle, char 32

Alarm Handles (multiple possible separated by commas) */, char 8, char 8 etc

Panel Prefix Handle, char 32

Panel Type Handle, char 32

Panel Loop Handle, char 32

Panel Suffix Handle, char 32

Symbol Name, char 32

Block Label, char 16

Function Label, char 16

Prefix Label, char 32

Type Label, char 32

Loop Label, char 32

Suffix Label, char 32

Alarm Labels (multiple possible separated by commas) */, char 8, char 8 etc

Panel Prefix Label, char 32

Panel Type Label, char 32

Panel Loop Label, char 32

Panel Suffix Label, char 32

Instrument Description, char 80

Signal Styles (multiple possible separated by commas) */,char 32,char 32 etc

Number of signals, number

Conditioner/Descriptor, char 80

Location, char 32

Process Owner , char 132

Owner Handle , char 32

Owner Atype, char 10

Owner Id, number

Size, char 10

Specification, char 10

Area, char 10

Paintcode, char 10

12.19:12© 2011 AVEVA Solutions Ltd

Page 637: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Insulation (Table), char 10

Insulation (Index ), char 10

Insulation (Condition), char 10

Tracing (No of Tracers), char 10

Tracing (Size), char 10

Tracing (Type), char 10

Graphical tracing, char 10

Grid Reference, char 8

Units, char 4

Interlock, char 4

Pattern Item, char 4 ('*' if pattern)

Panel Type, char 4 (I or E)

Typical Item, char 4 ('*' if typical)

9.2.7 Remote Instrument Information - .irm fileItem Handle, char 32

Prefix Handle, char 32

Type Handle, char 32

Loop Handle, char 32

Suffix Handle, char 32

Alarm Handles (multiple possible separated by commas) */, char 8, char 8 etc

Panel Prefix Handle, char 32

Panel Type Handle, char 32

Panel Loop Handle, char 32

Panel Suffix Handle, char 32

Symbol Name, char 32

Block Label, char 16

Function Label, char 16

Prefix Label, char 32

Type Label, char 32

Loop Label, char 32

Suffix Label, char 32

Alarm Labels (multiple possible separated by commas) */, char 8, char 8 etc

Panel Prefix Label, char 32

Panel Type Label, char 32

Panel Loop Label, char 32

12.19:13© 2011 AVEVA Solutions Ltd

Page 638: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Panel Suffix Label, char 32

Instrument Description, char 80

Signal Styles (multiple possible separated by commas) */,char 32,char 32 etc

Number of signals, number

Conditioner/Descriptor, char 80

Location, char 32

Grid Reference, char 8

Interlock, char 4

Pattern Item, char 4 ('*' if pattern)

Panel Type, char 4 (I or E)

Typical Item, char 4 ('*' if typical)

9.2.8 In-Line Valves Information - .ivl fileInst valve handle, char 32

Label balloon handle, char 32

Link line handle, char 32

Prefix label handle, char 32

Letters label handle, char 32

Loop label handle, char 32

Suffix label handle, char 32

Panel ref prefix handle, char 32

Panel ref letters handle, char 32

Panel ref loop handle, char 32

Panel ref suffix handle, char 32

Symbol name, char 32

Prefix label, char 32

Letters label, char 32

Loop label, char 32

Suffix label, char 32

Panel ref prefix label, char 32

Panel ref letters label, char 32

Panel ref loop label, char 32

Panel ref suffix label, char 32

Descriptor label, char 80

Tag Description, char 80

Branch id, number

12.19:14© 2011 AVEVA Solutions Ltd

Page 639: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Sequence, number

Inlet Size, char 10

Outlet Size, char 10

Specification, char 10

Area, char 10

Paintcode, char 10

Insulation(Table), char 10

Insulation(Index), char 10

Insulation(Condition), char 10

Tracing (No of Tracers), char 10

Tracing (Size), char 10

Tracing (Type), char 10

Graphical tracing, char 10

AVEVA P&ID type, char 4

Symbol Description, char 80

Valve body, char 32

Actuator type, char 32

Signal Type connected, char 32

Handwheel (Y/N), char 4

Valve tag, char 32

Closure, char 32

Grid ref, char 8

Units, char 4

PDMS type, char 4

PDMS Sub-type, char 4

Interlock (Y/N), char 4

Pattern Item, char 4 ('*' if pattern)

Panel Type, char 4 (I or E)

Typical Item, char 4 ('*' if typical)

9.2.9 System Output Information - .isy fileItem handle, char 32

Label handle, char 32

Label, char 32

Grid ref, char 8

12.19:15© 2011 AVEVA Solutions Ltd

Page 640: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.2.10 Pipe Information - .pip fileBranch id, number

Owner branch id, number

Size, char 10

Fluid/Service, char 10

Number, char 10

Area, char 10

Specification, char 10

Insulation (Table), char 10

Insulation (Index), char 10

Insulation (Condition), char 10

Paint Code, char 10

Tracing (No of Tracers), char 10

Tracing (Size, char 10)

Tracing (Type), char 10

Project1 (Project definable), char 10

Project2 (Project definable), char 10

Project3 (Project definable), char 10

Graphical Tracing type, char 10

From, char 132

To, char 132

Connected PDMS type (From), char 10

Connected PDMS type (To), char 10

Pipe route error flag, char 4

Connected Handle (From), char 32

Connected Handle (To), char 32

Typical Item, char 4 ('*' if typical)

9.2.11 Pipe Item Information - .pit fileItem handle, char 32

Branch id, number

Sequence, number

AVEVA P&ID type, char 4

Inlet Size, char 10

Outlet Size, char 10

Spec, char 10

12.19:16© 2011 AVEVA Solutions Ltd

Page 641: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Area, char 10

Paint code, char 10

Insulation (Table), char 10

Insulation (Index), char 10

Insulation (Condition), char 10

Tracing (No of Tracers), char 10

Tracing (Size), char 10

Tracing (Type), char 10

Graphical tracing, char 10

Description, char 80

Valve tag, char 32

Closure tag, char 32

Spp Prefix, char 16

Spp Letters, char 16

Spp Numbers, char 16

Spp Suffix, char 16

Valve Code, char 32

Valve Body, char 32

Grid ref, char 8

PDMS type, char 4

PDMS Sub-type, char 4

Typical Item, char 4 ('*' if typical)

Symbol name (no character restriction)

9.2.12 Notes Information - .nte fileLabel handle, char 32

Owner handle, char 32

Label, char 132

9.2.13 Link Connectivities Information - .con fileItem Handle, char 32

Connected Item Handle, char 32

9.2.14 User-Defined Attributes Information - .usd fileOwner Handle, char 32

Attribute Name, char 200

Attribute Value, char 256

12.19:17© 2011 AVEVA Solutions Ltd

Page 642: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Owner Type, char 4

Drawing Units, char 32

9.2.15 Valve Port Information - .por fileOwner Handle, char 32

Port Identifier, char 32

Port Size, char 10

Connected Item Handle, char 32

Connected Item Type, char 4

9.2.16 Monitor File - .mon fileA Monitor File is created each an export takes place. This file may be examined in any standard text editor, and lists any problems found during the process, for example, nozzles without labels or pipes incorrectly routed. If an export is carried out more than once from the same flow diagram, the previously created monitor file is overwritten. The monitor file is created in the working directory, as set in the project configuration file. Other output files are created in the data directory.

9.3 AVEVA P&ID Item Types and Label Types Item Types are listed below under the following headings:

• Pipes, Trim and Process Links Item Types• Signal Line Item Types• Tracing Item Types• Symbol Item Types • Label Types

9.3.1 Pipes, Trim and Process Links Item Types PMA - Main Pipe (and Process Link post AVEVA VPE P&ID 7.2 SP3)

PSU - Subsidiary Pipe

PLK - Process Link (pre AVEVA VPE P&ID 7.2 SP3)

BSN - Branch Start Node

BEN - Branch End Node

9.3.2 Signal Line Item Types SHY - Signal Line (Hydraulic)

SDL - Signal Line (Datalink)

SPN - Signal Line (Pneumatic)

SEL - Signal Line (Electric)

SUD - Signal Line (Undefined)

SCT - Signal Line (Capillary Tube)

12.19:18© 2011 AVEVA Solutions Ltd

Page 643: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

SSO - Signal Line (Sonic)

SFL - Signal Line Flag - **System Generated

9.3.3 Tracing Item Types GTR - Graphical Tracing

GTA - Graphical Trace Around - **System Generated

9.3.4 Symbol Item Types ACT - Actuator

BEI - In-Line Equipment Label Symbol

BEQ - Equipment Label Symbol

BPI - Pipe Label Symbol

CHC - Change Cloud

EDL - Equipment Data Location

EI3 - In-line Equipment (Three-Way)

EI4 - In-line Equipment (Four-Way)

EIA - In-line Equipment (Angle)

EIN - In-line Equipment

EQE - Electrical Equipment

EQU - Equipment Item

EQV - Equipment Vessel

GRP - Assembly - **System Generated

IBD - Instrument Bursting Disc

IC3 - Instrument Control Valve Three-Way

IC4 - Instrument Control Valve Four-Way

ICA - Instrument Control Valve Angled

ICD - Instrument Conditioning Device

ICV - Instrument Control Valve

IDC - DCS Instrument

IFE - Instrument Flow Element

IHW - Instrument Handwheel

IIO - Instrument I/O Device (I/O Rocket)

ILB - Instrument Label Balloon - **System Generated

ILL - Instrument Label Link Line - **System Generated

INS - Instrument

IPO - Instrument Port Valve

IR3 - Instrument Relief Valve Three-Way

12.19:19© 2011 AVEVA Solutions Ltd

Page 644: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

IR4 - Instrument Relief Valve Four-Way

IRA - Instrument Relief Valve Angled

IRV - Instrument Relief Valve

ISO - System I/O Boxes

IV3 - Instrument Valve Three-Way

IV4 - Instrument Valve Four-Way

IVA - Instrument Valve Angled

IVL - Instrument Valve

LCK - Interlock

LF3 - Line Fitting 3 Way

LF4 - Line Fitting 4 Way

LFA - Line Fitting Angle

LFI - Line Fitting

LIG - Line Fitting Ignored by Router

LIN - Insulation Line Fitting Ignored by Router

LSP - Spec Break

LST - Line Stream Diamond

MIS - Miscellaneous

NOZ - Nozzle

PDF - Pipe Destination Fitting

PEN - Pipe End Node

PFA - Pipe Flow Arrows

PFL - Pipe On/Off Connection Flag

POR - Ports

PSN - Pipe Start Node

RDC - Concentric Reducer

RDE - Eccentric Reducer

RPB - Error Report Cell

RTR - Revision Triangles

VL3 - Three Way Valve

VL4 - Four Way Valve

VLA - Angle Valve

VLV - Pipe Valve

VPO - Piping Port Valve

12.19:20© 2011 AVEVA Solutions Ltd

Page 645: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.3.5 Label Types X01 - Title Minimum Line Number

X02 - Title Maximum Line Number

X03 - Title Last Line Number Used

X04 - Title Minimum Line Number

X05 - Title Maximum Line Number

X06 - Title Last Line Number Used

X07 - Title Minimum Line Number

X08 - Title Maximum Line Number

X09 - Title Last Line Number Used

X10 - Title Minimum Line Number

X11 - Title Maximum Line Number

X12 - Title Last Line Number Used

X13 - Title Minimum Loop Number

X14 - Title Maximum Loop Number

X15 - Title Last Used Loop Number

X16 - Title Minimum Loop Number

X17 - Title Maximum Loop Number

X18 - Title Last Used Loop Number

X19 - Title Cancelled Line Number

X20 - Title Cancelled Line Number

X21 - Title Cancelled Line Number

X22 - Title Cancelled Line Number

X23 - Title Cancelled Loop Number

X24 - Title Cancelled Loop Number

XAI - Area Field on Spec Breaks

XAP - Revision Approved Label

XAR - Title Design Area

XBI - Branch Identifier

XCH - Revision Checked Label

XCI - Paint Code on Spec Break

XCN - Client Number

XD1 - Revision Description Label 1

XD2 - Revision Description Label 2

XDA - Revision Date Label

XDL - Equipment Data Location

12.19:21© 2011 AVEVA Solutions Ltd

Page 646: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

XDN - Drawing Number

XDR - Drawing Revision

XDS - Drawing Sheet

XDT - Drawing Title

XEN - Equipment Number (not used if fixed equipment label formatting is on)

XEP - Equipment Prefix (not used if fixed equipment label formatting is on)

XEQ - Equipment (Entire label if fixed equipment label formatting is on, Equipment Letter only if off)

XES - Equipment Suffix (not used if fixed equipment label formatting is on)

XGR - Revision Grid Reference

XI1 - Insulation on Spec Break

XI2 - Insulation on Spec Break

XI3 - Insulation on Spec Break

XIA - Instrument Alarm

XID - Instrument Descriptor

XIL - Instrument Loop

XIO - System I/O Ident

XIP - Instrument Prefix

XIS - Instrument Suffix

XIT - Instrument Tag

XL1 - Insulation Line Fitting Label (Table)

XL2 - Insulation Line Fitting Label (Index)

XL3 - Insulation Line Fitting Label (Cond)

XLB - Inline Insulation Label (Table)

XLC - Inline Insulation Label (Cond)

XLI - Inline Insulation Label (Index)

XLL - Panel Loop Label

XLP - Panel Prefix Label

XLS - Panel Suffix Label

XLT - Panel Tag Label

XNE - Note

XNS - Nozzle Size

XNT - Nozzle Tag

XPD - Pipe Destination Text

XPF - Pipe Flag

XPI - Pipe

12.19:22© 2011 AVEVA Solutions Ltd

Page 647: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

XPJ - Revision Project Label

XPN - Project Number

XPP -Port Valve Port Size

XPR - Pattern Label

XR1 - Revision Number Label (in triangle)

XR2 - Revision Number Label (title block)

XR3 - Revision Number (see XGR)

XRA - I/O Address

XRC - I/O Card Type

XRI - Reducer

XRP - Error Report Cell Label

XRR - I/O Remark

XRS - I/O Signal Type/Area Code

XRV - Revision Revised Label

XSF - Signal Line Flag

XSI - Spec Break

XSL - Special Piping Item Letters

XSN - Special Piping Item Numbers

XSP - Special Piping Item Prefix

XSS - Special Piping Item Suffix

XST - Stream

XT1 - Tracing on Spec Break

XT2 - Tracing on Spec Break

XT3 - Tracing on Spec Break

XTB - Trim Size

XTR - Trim

XVC - Valve Closure

XVD - Valve Code

XVR - VPE Workbench Field Designator

XVS - Valve Size

XVT - Valve Tag

XVV - VPE Workbench Field Value

12.19:23© 2011 AVEVA Solutions Ltd

Page 648: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.4 AutoCAD Defaults set by AVEVA P&ID When AVEVA P&ID is loaded, a number of AutoCAD settings and variables are automatically set.

Ortho and Osnap modes are switched On by default.

Several changes have been made to the range of normal AutoCAD commands which may be used when AVEVA P&ID is loaded.

AutoCAD variables should not be set before loading AVEVA P&ID, as the latter sets certain of these to its own values on start-up. The following AutoCAD variables are set to the values shown when AVEVA P&ID is loaded:

For explanations of the effects of changing these variables, consult an AutoCAD Reference Manual.

Variable Value

APERTURE 3

ATTDIA 1

BLIPMODE 0

COORDS 2

DRAGMODE 2

EXPERT 1

FILEDIA 1

HIGHLIGHT 1

LIMCHECK 0

MIRRTEXT 0

ORTHOMODE 1

OSMODE 0

PDMODE 0

PDSIZE 0

PICKBOX 3

REGENMODE 0

SNAPMODE 1

SNAPSTYL 0

UCSICON 0

12.19:24© 2011 AVEVA Solutions Ltd

Page 649: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.5 The ISO15926 (Version 3.2.0) Schema Specification

9.5.1 IntroductionThis version of the schema must be used when exporting data to the 12.0 SP4 version of PDMS or earlier.

If exporting data that is to be imported by the 12.0 SP5 version of PDMS or later, the 3.3.3 version of the schema may be used. See 9.6: The ISO15926 (Version 3.3.3) Schema Specification.

• NotationWhere the notation ‘…’ is used in examples it implies content that has been omitted due to it not being relevant for the example.

Elements in examples have been abbreviated to <Tag … /> to show structure but limit content.

9.5.2 XML Model Details

• XML File Document StructureThe document structure is defined in the XML schema for the P&ID profile (See below). An output file that conforms to this document must validate against the profile schema.

The first line of the file must be an XML declaration, for example:

The document is to be encoded using UTF-8.

The root node of an XML file is a PlantModel element. See below for the definitions of its attribute and element contents.

XML elements are not defined within an XML namespace and so are not namespace qualified.

The following class model provides an overview of the significant structural elements contained within an AVEVA P&ID XML profile file. The bi-directional arrows indicate and

<?xml version="1.0" encoding="UTF-8" ?>

12.19:25© 2011 AVEVA Solutions Ltd

Page 650: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

parent/child element relationship in the XML file. The elements and their attributes are defined in the Element Definitions section below.

Each structural element may contain geometric and text elements to represent the drawing contents.

• XML TopologyA PipingNetworkSegment, as its upstream reference (PipingNetworkSegment/Connection/@FromID), will reference a Nozzle, splitting component (such as a Tee, Wye or Cross), Reducer or SpecificationBreak that it doesn't contain or it will reference a PipeConnector that it contains.

A PipingNetworkSegment, as its downstream reference (PipingNetworkSegment/Connection/@ToID), will reference a Nozzle, merging component (such as a Tee, Wye or Cross) or SpecificationBreak that it doesn't contain or it will reference a splitting component (such as a Tee, Wye or Cross), Reducer or PipeConnector that it contains. Nb All PipingNetworkSegment elements are split where there is splitting component ( such as a Tee, Wye or Cross) or a Reducer.

Contained components, with the exception of PipeConnectors require a ToNode attribute which references the downstream ConnectionPoint of the component (i.e. the main flow out of the segment).

Components contained by other segments must be referenced using a ToNode or FromNode attribute as appropriate.

12.19:26© 2011 AVEVA Solutions Ltd

Page 651: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

References to Nozzle, PipeConnector and SpecificationBreak elements do not require ToNode/FromNode attributes..

• Geometries (Axis and Reference)All geometries in an XMpLant file are accompanied by Axis and Reference elements. These define rotations around 3 dimensional axis that define how to map the coordinates defined for the item into the target environment. For most 2D drawing work the following values give the expected behaviour (i.e. the coordinates are defined in the 2D drawing plane).

<Axis X="0" Y="0" Z="1"/>

<Reference X="1" Y="0" Z="0"/>

Some curve primitives such as ellipses in XMpLant require more complex use of Axis and Reference in order to define the 2D forms.

The <Axis> value defines a unit vector in 3D space about which an object should rotate. For 2D diagrams nearly all geometries will define this element as <Axis X="0" Y="0" Z="1"/> which denotes a vector aligned with the Z-axis.

The <Reference> element defines what is effectively the rotation about the <Axis> element. When you see the value written as <Reference X="1" Y="0" Z="0"/> it indicates that the X-Axis with which the object's points are defined use the same X-Axis on the output surface/window with which to orientate - in other words no rotation is required when you have the following paired elements;

<Axis X="0" Y="0" Z="1"/>

<Reference X="1" Y="0" Z="0"/>

• Character EncodingXML is encoded using UTF-8. This means that most characters used in western languages are encoded using a single byte representation, more complex characters are encoded

12.19:27© 2011 AVEVA Solutions Ltd

Page 652: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

using either a 2 byte encoding or a substitution mechanism. Where the export capabilities are limited to a single byte representation or software is developed with limited knowledge of UTF-8 it is common practice to output the 2 byte characters using a numerical substitution syntax of &#nnn; where nnn denotes the character code.

P&ID Manager is very limited in the way that characters are supported because the base storage has fixed length text types (120 characters) and limited character support. If two byte characters are provided to P&ID Manager then they will be substituted numerically when stored so that the database character constraints can be met. This substitution compromises the amount of text stored as a single character will be converted to ~5 characters to complete the substitution. When exporting to XML bear in mind that the string data contents loaded into P&ID Manager will be constrained to 120 characters in length after two byte characters have been substituted numerically and XML substitutions have been reversed (such as ‘?’ -> ‘&#FEA6;’, ‘&amp;’ ->’&’, ‘&lt;’ -> ‘<’ etc).

• Tag ReferencingTag attributes may be used to reference elements instead of referencing by the ID attribute. The XML profile prefers the use of ID referencing as it gives a consistent referencing mechanism that can be used regardless of the presence of a Tag attribute.

If Tags are used then there is a special case for referencing Nozzle elements. In this instance the Tag is only unique within the scope of the containing Equipment element so the Equipment Tag must also be included in the reference. The reference must have the form <EquipmentTag>-<NozzleTag> and can only be used where the <NozzleTag> component doesn’t contain a ‘-‘ character.

For Example:

Where:

Equipment/@Tag = ‘VP-1234-DNJ09’

Equipment/Nozzle/@Tag = ‘N1’

The reference would be:

VP-1234-DNJ09-N1

• PersistentId ReferencingAs long as the context attribute used to scope PersistentID elements is at least equal in scope to the file scope then PersistentId attributes may be used for cross referencing elements. The PersistentID/@Identifier value is supported I any ItemId attribute.

9.5.3 Shared Attribute Definitions

• IDThe ID attributes of XML elements has the form ‘XMP_<n>’ where n is a sequential number within the XML file. These id values may be used for cross referencing elements and are transient. i.e. these ids are generated for each version of the file and cannot be used to match file contents between two different exports of the same drawing.

For example :-

<PipingNetworkSegment ID=”XMP_23” … >

12.19:28© 2011 AVEVA Solutions Ltd

Page 653: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• TagThis should contain the full Tag for an item without additional text. This is an xsd:string attribute with no specific validation (see Character encoding for character constraints)

• SpecificationThis is a free text field that has no clearly defined semantics. Specification information may be best represented in GenericAttributes.

• StockNumberThis is defined as:

‘A code that will identify a purchasable plant item

‘The StockNumber attribute contains the unique name of this component that can be used to relate to the complete set of information that is contained in the vendor catalogue for the component. This attribute taken with the Specification and NominalDiameter will identify a specific item, fully defining its parameters size and optionally material and all other information available for it.’

This attribute is an xsd:string attribute and has no specific validation or constraints other than those defined in the ‘Character encoding’ section of this document.

• ComponentNameIf present on a component that is inside a ShapeCatalogue element then this is the unique id for the symbol within the XML file.

If present on a component that is not inside a ShapeCatalogue element then this is the reference to the geometry of the components symbol. The component may have additional annotation defined within it (See also Scale).

• ComponentClassThe format of the ComponentClass attribute is documented in the XML Model Overview section. The attribute is the RDL Designation field from the ISO 15926 RDL specification. The value of this field is converted to Camel Case with all spaces removed. Notes : some fields contain characters that must be substituted when written in XML (e.g. ‘&’ characters must be substituted with &amp;). For example:

GATE VALVE -> GateValve

CENTRIFUGAL PUMP -> CentrifugalPump

• ComponentTypePermitted values :-

‘Normal’

‘Explicit’

‘Parametric’

12.19:29© 2011 AVEVA Solutions Ltd

Page 654: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• RevisionIf known this attribute should contain the revision or version of the item. This has the type of xsd:string and therefore has no specific syntax or format constraints other than those detailed in Character encoding.

• StatusOne of the following values :-

‘Current’ – This implies this is the latest version of an item

‘Deleted’ – This item has been superseded or removed from the drawing.

‘Modified’ – The last change to this item was a modification.

‘New’ – This is the first version of the item in the drawing.

If the item has a status of ‘Deleted’ then the item will be ignored by P&ID Manager.

Items will be deleted by Manager if they have a status of Deleted or if they do not appear in the new version of a file and used to exist.

• UnitsThe Units attribute is to be taken from the ISO15926 RDL catalogue using the name from the catalogue converted to camel-case. All measurement values such as distances and pressures are either accompanied by their units of measure or defaulted to the value provided on the PlantInformation/UnitsOfMeasure element. The unit of measure for the coordinate geometry is stipulated in the PlantInformation/@Units attribute. The permitted values are as follows:

Angles:

Degree, Radian, deg, rad

Area :

SquareMillimetre, SquareCentimetre, SquareMetre, SquareKilometre, SquareInch, SquareFoot, SquareYard, SquareMile, sq mm, sq cm, sq m, sq km

Distances:

Micron, Millimetre, Centimetre, Decimetre, Metre, Kilometre, Inch, Foot, Yard, Mile, mm, cm, m, km, in, ft, yd

Pressures:

MillinewtonMetreSquared, NewtonMetreSquared, KilonewtonMetreSquared, Picopascal, Micropascal, Millipascal, Pascal, Kilopascal, Megapascal, Gigapascal, Bar, Bara, Barg

Temperatures:

DegreeKelvin, DegreeCelsius, DegreeRankine, DegreeFahrenheit, degC, degF, degK

Volume :

CubicMillimetre, CubicCentimetre, CubicMetre, CubicInch, CubicFeet, CubicYard, cc, litres, gallons, USGallons, barrels

Weight:

12.19:30© 2011 AVEVA Solutions Ltd

Page 655: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Microgram, Milligram, Gram, Kilogram, Megagram, PoundMass, OunceMass, mg, Kg, lb, oz

Note: All values are case sensitive.

9.5.4 Element Definitions• PlantModel • Association • Axis • BsplineCurve• CenterLine • Circle • Component• CompositeCurve • Connection • ConnectionPoints • ConnectionType • ControlPoints • ControlPointWeight • Coordinate • CrossPageConnection • Description • Discipline • Drawing • DrawingBorder • Ellipse • EndDiameter • Equipment • Extent • FabricationCategory • GenericAttributes • GeometricPrimitives • Height • History • Identifier• IdentifierElement • InsideDiameter • InstrumentLoop• KnotMultiplicities • Knot • Knots • Line • Location • Manufacturer

12.19:31© 2011 AVEVA Solutions Ltd

Page 656: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• Material• MaterialDescription • Max • MaximumDesignPressure • MaximumDesignTemperature • MaximumOperatingPressure • MaximumOperatingTemperature • Min • MinimumDesignPressure• MinimumDesignTemperature • MinimumOperatingPressure• MinimumOperatingTemperature • ModelNumber • Multiplicity • NominalDiameter • NormalDesignPressure • NormalDesignTemperature • NormalOperatingPressure• NormalOperatingTemperature • Nozzle • NozzleType • OperatorType • OutsideDiameter • PConnectionPoints • PersistentID• PipeConnector• PipeFlowArrow • PipingNetworkSystem • PipingComponent • PipingNetworkSegment • PlantArea • PlantInformation • PlantItem • Point • PolyLine • Position • Presentation • ProcessInstrument• Rating• Reference • Remark • Scale • Shape

12.19:32© 2011 AVEVA Solutions Ltd

Page 657: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• ShapeCatalogue • SignalConnectorSymbol• SignalLine • SpecificationBreak• StartDiameter • String • Supplier • Surface • TestPressure • Text • Transaction • TrimmedCurve • UnitsOfMeasure • WallThickness • Weight • WeightsData

• PlantModelThis is the root node of an XML document and only exists as the root node of an XML file. Other than the first two child elements, PlantInformation and Extent, the ordering of child elements within a PlantModel element is not significant.

There shouldn’t be any need to place graphical elements into a PlantModel element as all drawing annotation such as borders and floating text should be child elements of the drawing element.

While a Position element may be provided is has no attached semantics and is often defaulted to 0,0,0.

Child Elements:

Element Name Cardinality Description

PlantInformation 1 The properties of a plant model This includes properties like its name, modification date, editing system etc. The PlantInformation element must be the first child element of a PlantModel element.

Extent 1 The minimum bounding rectangle that encloses the full graphical contents of the PlantModel instance. The Extent element must be the second child element of a PlantModel element

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A composite geometry

Drawing 1 Metadata and graphical annotation related to the P&ID drawing being represented

12.19:33© 2011 AVEVA Solutions Ltd

Page 658: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<?xml version="1.0" encoding="UTF-8" ?><PlantModel xmlns:xsi=http://www.w3.org/2001/XMLSchema-instance

xsi:noNamespaceSchemaLocation=".\XMLSchema.xsd"><PlantInformation … /><Extent … /><Drawing … /><ShapeCatalogue … /><Equipment … />…

</PlantModel>

Ellipse 0..* A geometric primitive

Equipment 0..* The representation of a piece of plant equipment.

GenericAttributes 0..* Source system properties that relate to the XML file and plant model. These properties may be grouped into many GenericAttributes elements.

GeometricPrimitives 0..* A collection of geometric primitives.

InstrumentLoop 0..* A grouped set of instrument detail

Line 0..* A geometric primitive

PipingNetworkSystem 0..* An Engineering PipingNetworkSystem element

PipeLine 0..* An Engineering PipeLine element

PlantArea 0..* A place holder for Area information

Point 0..* A geometric primitive

PolyLine 0..* A geometric Primitive

Position 0..1 Usually defaulted to 0,0,0 if output.

Presentation 0..* Style information for this object. In this context it has no meaning and should be omitted.

ProcessInstrument 0..* An Engineering Instrument object

Shape 0..* A geometric primitive

ShapeCatalogue 0..* A catalogue of Equipment and PipingComponent symbols.

SignalLine 0..* A connection between instruments.

Text 0..* Label primitives

TrimmedCurve 0..* A geometric primitive

Element Name Cardinality Description

12.19:34© 2011 AVEVA Solutions Ltd

Page 659: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• AssociationThe Association element is used to relate engineering items to other resources.

One documented use of this is to relate in-line ProcessInstrument elements with InstrumentLoop elements. In this case each in-line ProcessInstrument element has an Association child element which details the relationship using the Type attribute with a value of ‘is a part of’.

Child elements :

None

Attributes:

Example:

<ProcessInstrument ...><Association Type="is a part of" ItemID="XMP_235"/>...

</ProcessInstrument>

• AxisSee Geometries (Axis and Reference).

Child elements :

None

Attributes :

Attribute Name Required Description

Type Y The meaning/semantics of the relationship.

ItemID N The ID or PersistentID/@Identifier attribute value of the item being referenced.

Tag N The Tag attribute value of the item being referenced. (See Tag Referencing)

Name N The Name attribute value of the item being referenced.

URI N A URI identifying an associated resource

Context N If omitted then the resource is assumed to be part of the model in the same file. If you want to state the context as the current model then use the value ‘XML’.

Attribute Name Required Description

X Y

Y Y

Z Y

12.19:35© 2011 AVEVA Solutions Ltd

Page 660: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<Axis X="0" Y="0" Z="1" />

• BsplineCurveGeometric curve primitive detailing a Bspline.

Child elements:

Attributes:

Example:

BsplineCurve Degree="3" CurveType="BsplineCurveWithKnots" NumControlPoints="4" NumKnots="8"><Presentation Layer="" Color="-32363" LineType="0"

LineWeight="1" R="0.67" G="0.38" B="0"/><Extent>

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the Bspline. The drawing behaviour is undefined if the Presentation element is missing.

Extent 1 The minimum bounding geometry of this element and its descendants

ControlPoints 1

KnotMultiplicities 0..1

Knots 0..1

WeightsData 0..1

GenericAttributes 0..1 Any application specific attributes relating to the Bspline

Attribute Name Required Description

Degree Y

CurveType Y One of the following : 'BsplineCurve', 'BsplineCurveWithKnots' or 'RationalBsplineCurve'.

CurveForm N One of the following : 'PolyLine', 'CircularArc', 'EllipticArc', 'ParabolicArc' or 'HyperbolicArc'

NumControlPoints Y x

NumKnots N x

Closed N 'true' or 'false'

SelfIntersect N 'true' or 'false'

12.19:36© 2011 AVEVA Solutions Ltd

Page 661: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Min X="10241.64" Y="10283.399" Z="40.9999850090838"/>

<Max X="10241.64" Y="10283.399" Z="41.0000151701423"/>

</Extent><ControlPoints>

<Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/>

</ControlPoints><Knots>

<Knot>0</Knot><Knot>1</Knot>

</Knots><KnotMultiplicities>

<Multiplicity>4</Multiplicity><Multiplicity>4</Multiplicity>

</KnotMultiplicities><WeightsData>

<ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight>

</WeightsData>

</BsplineCurve>

• CenterLineGeometric curve primitive detailing the line geometry between the components of a PipingNetworkSegment. A CenterLine element is used to imply the presence of tubing. The interpolation between each coordinate is linear.

Child elements:

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the line. The drawing behaviour is undefined if the Presentation element is missing.

Extent 1 The minimum bounding geometry of the CenterLine element and its descendants

Coordinate 1..* The coordinates defining the line primitive

GenericAttributes 0..* Any application specific attributes relating to the tube/CenterLine

12.19:37© 2011 AVEVA Solutions Ltd

Page 662: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<CenterLine NumPoints="2"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="77" Y="463" Z="0" /><Max X="646" Y="463" Z="0" />

</Extent><Coordinate X="77" Y="463" Z="0" /><Coordinate X="646" Y="463" Z="0" />

</CenterLine>

• CircleA geometric primitive describing a circle.

Child elements:

Attributes:

Example:

<Circle Radius="8"><Presentation LineType="Solid" LineWeight="1"

Color="22" R="0.79" G="0.239" B="0.087" />

<Extent><Min X="710" Y="258" Z="0" /><Max X="726" Y="274" Z="0" />

</Extent>

Attribute Name Required Description

NumPoints Y The number of child Coordinate elements.

Element Name Cardinality Description

Presentation 1 The style to use when drawing the circle

Extent 1 The minimum bounding geometry of the circle

Position 1 The location of the circles centre

GenericAttributes 0..* Any application attributes relating to the circle

Attribute Name Required Description

Radius Y The radius of the circle to draw

Filled N One of ‘Solid’ or ‘Hatch’. If not present the circle is not filled.

12.19:38© 2011 AVEVA Solutions Ltd

Page 663: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Position><Location X="718" Y="266" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Circle>

• ComponentUsed to group geometric and text primitives within a Drawing element. This inherits all elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents..

Child elements:

See ‘PlantItem’, no additional elements are defined.

Attiribute :

See ‘PlantItem’, no additional attributes are defined.

Example:

<Component ID="XMP_12" Tag><Extent>

<Min X="199.6153088" Y="155.02299606" Z="0" /><Max X="236.78321894" Y="194.01149803" Z="0" />

</Extent><Position>

<Location X="221" Y="182" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position>…<Text … /></Component>

• CompositeCurveA collection of geometric curve primitives

Child elements:

Element Name Cardinality Description

Presentation 0..1 The Presentation element has no purpose in this context.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A geometric primitive

12.19:39© 2011 AVEVA Solutions Ltd

Page 664: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

None

Example:

<CompositeCurve><Presentation LineType="Solid" LineWeight="1"

Color="22" R="0.79" G="0.239" B="0.087" />

<Extent><Min X="714.38797635" Y="260.50328515" Z="0" /><Max X="720.62485791" Y="263.00328515" Z="0" />

</Extent><Circle ... /><Circle ... /><PolyLine ... />

</CompositeCurve>

• ConnectionThis element is used to describe the flow connectivity between elements. The source of the flow is defined using the attributes FromID and FromNode while the flow destination is defined using ToID and ToNode. A connection element and its attributes are not mandatory but must be present to represent the topology of a network. If the FromID/ToID attributes reference a Nozzle, PipeConnector or SpecificationBreak element then the FromNode/ToNode attributes are not required.

See ConnectionPoints for details on what is being referenced.

Child elements:

None

Ellipse 0..* A geometric primitive

Line 0..* A geometric primitive

Polyline 0..* A geometric primitive

Shape 0..* A geometric primitive

TrimmedCurve 0..* A geometric primitive

GenericAttributes 0..* Any application specific properties relating to the Drawing.

Element Name Cardinality Description

12.19:40© 2011 AVEVA Solutions Ltd

Page 665: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<PipingNetworkSegment … >…<Connection FromID="XMP_73" ToID="XMP_4" ToNode="2" />…

</PipingNetworkSegment>

• ConnectionPointsThis element is used to describe the potential flow connections from and to the parent of this element. Each potential connection location is represented as a Node element. Nodes are ordered and positioned on the drawing. Each Node element may be referenced by at most one Connection element.

The first node (known as Node 0) represents the geometric origin of the parent of the ConnectionPoints element.

Child elements:

Attribute Name Required Description

ToID N The ID, PersistentID/@Identifier or Tag of the referenced item that is the flow destination for the parent of the Connection element.

ToNode N The index of the ConnectionPoints Node element within the ConnectionPoints element of the destination element. Nb this is a 0 based index and is only required if the destination is not a Nozzle, PipeConnector or SpecificationBreak.

FromID N The ID, PersistentID/@Identifier or Tag of the referenced item that is the flow source for the parent of the Connection element. See Tag Referencing

FromNode N The index of the ConnectionPoints Node element within the ConnectionPoints element of the source element. Nb this is a 0 based index and is only required if the source is not a Nozzle, PipeConnector or SpecificationBreak.

Element Name Cardinality Description

Presentation 0..1 The Presentation element has no purpose in this context.

Extent 0..1 The minimum bounding geometry of the geometric contents of the ConnectionPoints element and its descendants.

12.19:41© 2011 AVEVA Solutions Ltd

Page 666: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<ConnectionPoints NumPoints="4" FlowIn="1" FlowOut="2"><!-- Node 0 : Geometric origin of the component --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Node><!-- Node 1 : FlowIn default --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><NominalDiameter Value="4" />

</Node><!-- Node 2 : FlowOut default --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

Node 1..* The first node (Node 0) represents the geometric location of the parent element. Nodes 1..n represent the locations that other elements may connect to.

GenericAttributes 0..* Any Application attributes related to connectivity

Attribute Name Required Description

NumPoints Y The number of Node elements in this ConnectionPoints element.

FlowIn N The index of the Node that is used for the primary flow into the parent of the ConnectionPoints element. This Defaults to 1 if not present.

FlowOut N The index of the Node that is used for the primary flow from the parent of the ConnectionPoints element. This defaults to 2 if not present.

Element Name Cardinality Description

12.19:42© 2011 AVEVA Solutions Ltd

Page 667: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

</Position><NominalDiameter Value="4" />

</Node><!-- Node 3 : Secondary flow, direction not stated --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><NominalDiameter Value="4" />

</Node></ConnectionPoints>

• ConnectionTypeThis is a free form string element that may be unit qualified.

Child elements:

None

Attributes:

Example:<ConnectionType>Welded</ConnectionType>

• ControlPointsChild elements :

Attributes:

None

Example:

<ControlPoints><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/>

</ControlPoints>

• ControlPointWeightThis is defined as an any but should be considered to be of type xsd:integer.

Attribute Name Required Description

Units N This may contain any of the permitted units types See Units.

Element Name Cardinality Description

Coordinate 1..*

12.19:43© 2011 AVEVA Solutions Ltd

Page 668: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

None

Attributes :

None

Example:

<ControlPointWeight>1</ControlPointWeight>

• CoordinateA Coordinate element is a Tuple of ordinates denoting a location in the drawing plane. For 2D drawings the Z ordinates should always be 0.

Child elements:

None

Attributes:

Example:

<Coordinate X="112" Y="106" Z="0" /><Coordinate X="112" Y="110" />

• CrossPageConnectionAn element describing how to match PipeConnector elements to represent cross page connectivity on a P&ID.

Child elements:

None

Attributes:

Attribute Name Required Description

X Y The X Axis ordinate as a double

Y Y The Y Axis ordinate as a double

Z N The Z Axis ordinate as a double, If not present this defaults to 0.0

Attribute Name Required Description

DrawingName N The Name attribute of the Drawing that the matching PipeConnector is on. Depending on whether the attribute for matching is unique to a drawing or the entire project this may be required.

AttributeName Y The attribute name on the PipeConnector to use to match the connectors together. This could be an ItemAttribute such as the Tag or ID, or a member of a GenericAttributes element.

12.19:44© 2011 AVEVA Solutions Ltd

Page 669: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<CrossPageConnection DrawingName="A1-51-2003-1" AttributeName="PersistentID" AttributeValue="{SOME_ID_1}" Context="http://www.aveva.com/example/P&amp;ID"/>

• DescriptionA textual description of an item

Child elements:

None

Attributes:

None

Example:<Description>some piece of plant equipment</Description>

• DisciplineThis is a simple element with no attributes containing one of the following values to classify an element:

Electrical

Mechanical

Process

HVAC

Telecomms

Example:

<Discipline>Mechanical</Discipline>

• DrawingThis contains metadata about the drawing and graphical annotation for the drawing that the XML file contains.

AttributeValue Y The value of the attribute to match on. Wildcards are not supported.

Set N If referencing an attribute inside a GenericAttributes element then the Set of the attribute should be provided.

If referencing a PersistentID attribute then the Context attribute value of the PersistentID should be provided here

Attribute Name Required Description

12.19:45© 2011 AVEVA Solutions Ltd

Page 670: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

Example:

<Drawing Name="A1-51-2003-1" Type="PID" Size="A0"

Element Name Cardinality Description

Presentation 1 The R, G and B values of this element define the background colour for the drawing. This is in contrast to the normal use of the Presentation element that defines foreground style information.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

Component 0..* A PlantItem used to group annotation.

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A geometric primitive

Ellipse 0..* A geometric primitive

Line 0..* A geometric primitive

Polyline 0..* A geometric primitive

Shape 0..* A geometric primitive

TrimmedCurve 0..* A geometric primitive

Text 0..* Textual annotation on the drawing

DrawingBorder 0..* This element may be used to store the drawing border/outline but this is at the discretion of the export tool.

GenericAttributes 0..* Any application specific properties relating to the Drawing.

Attribute Name Required Description

Name Y Identity for the drawing, this must be unique in the project.

Type Y Fixed value of ‘PID’

Revision N Free form string value. See Character encoding

Title Y The drawing title

Size N This is a free text string and has no defined syntax. See Character encoding.

12.19:46© 2011 AVEVA Solutions Ltd

Page 671: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Title="Sample Project drawing" Revision="A"><Presentation R="0" G="0" B="0" /><Extent>

<Min X="0" Y="-2" Z="0" /><Max X="850.0" Y="620.25" Z="0" />

</Extent><PolyLine NumPoints="4">…</PolyLine>…

</Drawing>

• DrawingBorderThis element may be used to separate the drawing frame and borders from the drawing annotation.

Child elements:

Attributes:

Element Name Cardinality Description

Presentation 0..1 The Presentation element has no purpose in this context.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A geometric primitive

Ellipse 0..* A geometric primitive

Line 0..* A geometric primitive

Polyline 0..* A geometric primitive

Shape 0..* A geometric primitive

TrimmedCurve 0..* A geometric primitive

Text 0..*

DrawingBorder 0..* This element may be used to store the drawing border/outline but this is at the discretion of the export tool.

GenericAttributes 0..* Any application specific properties relating to the Drawing.

Attribute Name Required Description

Name N Identity for the drawing border

Size N This is a free text string and has no defined syntax. See Character encoding.

12.19:47© 2011 AVEVA Solutions Ltd

Page 672: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<DrawingBorder Name="Top" Size="A0-Portrait"><Presentation R="0" G="0" B="0" /><Extent>

<Min X="0" Y="-2" Z="0" /><Max X="850.0" Y="620.25" Z="0" />

</Extent><PolyLine NumPoints="4">…</PolyLine>…

</DrawingBorder>

• EllipseA geometric primitive used to describe an ellipse.

Child elements:

Attributes:

Example:

<Ellipse PrimaryAxis="7.62" SecondaryAxis="3.83916"><Presentation Layer="Default" LineType="Solid" LineWeight="0.13 mm" Color="Red" R="1" G="0" B="0"/><Extent>

<Min X="184.52505999" Y="425.32167093" Z="0"/><Max X="199.76504821" Y="429.16757932" Z="0"/>

</Extent><Position>

<Location X="192.145059987" Y="425.328421759" Z="0"/>

<Axis X="0" Y="0" Z="1"/><Reference X="1" Y="0" Z="0"/>

Element Name Cardinality Description

Presentation 1 This defines the drawing style to be used for the ellipse.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

Position 1 The centre/origin of the ellipse to draw

GenericAttributes 0..* A geometric primitive

Attribute Name Required Description

PrimaryAxis Y Double describing the primary axis

SecondaryAxis Y double describing the secondary axis

Filled N A value of ‘Solid’ or ‘Hatch’. If not present the ellipse is not filled.

12.19:48© 2011 AVEVA Solutions Ltd

Page 673: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

</Position></Ellipse>

• EndDiameterThis is the internal bore for a segment or a PipingNetworkSystem at its destination.

Child elements:

None

Attributes:

Example:

<EndDiameter Value="4" />

<EndDiameter Value="200" Units="mm" />

• EquipmentAn Equipment element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attribute Name Required Description

Value Y The bore size

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

Discipline 0..1 Functional domain of Equipment

NormalOperatingPressure 0..1

MinimumDesignPressure 0..1

MaximumDesignPressure 0..1

MinimumDesignTemperature

0..1

MaximumDesignTemperature

0..1

Equipment 0..* Equipment considered part of this equipment

Nozzle 0..* Potential pipe connection to this equipment

12.19:49© 2011 AVEVA Solutions Ltd

Page 674: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<Equipment ID="XMP_12" Tag="P-1502B" ComponentClass="VerticalPump"

ComponentName="VPump" StockNumber="puv1"><Extent>

<Min X="199.6153088" Y="155.02299606" Z="0" /><Max X="236.78321894" Y="194.01149803" Z="0" />

</Extent><Position>

<Location X="221" Y="182" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><PersistentID Identifier="{A1-51-2003-1_Topology-EQUIPMENT-2}" Context="http://www.aveva.com/example/P&amp;ID" />…<Nozzle ID="XMP_14" Tag="N2" ComponentClass="FlangedNozzle"

StockNumber="flnn1">…

</Nozzle></Equipment>

• ExtentA minimum bounding geometry describing the minimum and maximum coordinates of the descendants of this elements parent.

Child elements:

Attributes:

Attribute Name Required Description

ProcessArea N A free form string identifying, if required, the process area that this equipment resides in (See Character encoding).

Purpose N A free form string describing the function of this equipment in the process (see Character encoding).

Element Name Cardinality Description

Min 1 Minimum values for all geometric descendants of the Extent elements parent.

Max 1 Maximum values for all geometric descendants of the Extent elements parent

12.19:50© 2011 AVEVA Solutions Ltd

Page 675: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

None

Example:

<Extent><Min X="199.6153088" Y="155.02299606" Z="0" /><Max X="236.78321894" Y="194.01149803" Z="0" />

</Extent>

• FabricationCategoryThis is a free form string element that may be unit qualified.

Child elements:

None

Attributes:

Example:

None

• GenericAttributesThis element permits application specific attributes/properties to be output into an XML file. The properties themselves must adhere to the following complex type definition:

<complexType name="GenericAttributeType" mixed="true"><attribute name="Format" type="xsd:string"/><attribute name="Value" type="xsd:string"/>

</complexType>

Child elements:

Attributes:

Attribute Name Required Description

Units N This may contain any of the permitted units types See Units.

Element Name Cardinality Description

Xsd:any @Number The contents of a GenericAttributes element are not validated and may be any valid XML content. However the XML applications will expect the contents to conform to the schema fragment provided above.

Attribute Name Required Description

Number Y The number of GenericAttributes inside this set.

Set N A name for this grouping of attributes.

12.19:51© 2011 AVEVA Solutions Ltd

Page 676: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:<GenericAttributes Number="6" Set="Instrument">

<TagSuffix Format="string" Value=" "/><LoopTagSuffix Format="string" Value=" "/><MeasuredVariableCode Format="string" Value="F"/><Description0 Format="string" Value="155"/><InstrumentTypeModifier Format="string" Value="CV"/><TagSequenceNo Format="string" Value="001"/>

</GenericAttributes>

• GeometricPrimitivesA collection of geometric elements.

Child elements:

Attributes:

Example:

<GeometricPrimitives NumPrimitives="3"><Extent>

<Min X="53" Y="125" Z="0"/><Max X="89" Y="130" Z="0"/>

</Extent><Circle ... /><Circle ... /><Surface ... />

Element Name Cardinality Description

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

Surface 0..* A geometric primitive

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A geometric primitive

Ellipse 0..* A geometric primitive

Line 0..* A geometric primitive

Polyline 0..* A geometric primitive

Shape 0..* A geometric primitive

TrimmedCurve 0..* A geometric primitive

Attribute Name Required Description

NumPrimitives N The number of primitives inside this set. (= number of child elements -1)

12.19:52© 2011 AVEVA Solutions Ltd

Page 677: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

</GeometricPrimitives>

• HeightThis is the height of the Nozzle origin on it’s parent Equipment, measured from the origin of the Equipment.

Child elements:

None

Attributes:

Example:<Height Value="1.3" Units="m"/>

• HistoryThis is provided to contain an audit trail of the changes to an item.

Child elements:

Attributes:

Example:

<History NumTransaction="3"><Transaction ... /><Transaction ... /><Transaction ... />

</History>

• IdentifierThis element is used to capture the structure of an identifier such as a Tag. Not usually used.

Attribute Name Required Description

Value Y The height value

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

Transaction 0..* An entry in the audit trail

Attribute Name Required Description

NumTransactions Y The number of Transaction child elements

12.19:53© 2011 AVEVA Solutions Ltd

Page 678: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

Example:

<Identifier Purpose="Tag breakdown"><IdentifierElement Name="start" Value="AB-"/><IdentifierElement Name="middle" ItemID="XMP_24"

DependantAttribute="[Prefix]-[Number]"/></Identifier>

• IdentifierElementA structural element describing part of the structure of an identifier.

Child elements:

None

Attributes:

Example:

<IdentifierElement Name="start" Value="AB-"/>

<IdentifierElement Name="middle" ItemID="XMP_24" DependantAttribute="[Prefix]-[Number]"/>

• InsideDiameterThis is the internal bore for an item at its source end.

Child elements:

Element Name Cardinality Description

IdentifierElement 0..* A structural component of an identifier.

Attribute Name Required Description

Purpose N A string describing the purpose of this element.

Attribute Name Required Description

Name Y The name of this part of the identifier

Value N Only required if dependantAttribute is not provided.

ItemID N Only required if an attribute is referenced on another item.

DependantAttribute N References an attribute from which this part of the identifier is derived. See Textfor a description of how this attribute is defined.

12.19:54© 2011 AVEVA Solutions Ltd

Page 679: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

None

Attributes:

Example:

<InsideDiameter Value="4" />

<InsideDiameter Value="200" Units="mm" />

• InstrumentLoopA collection of related instruments. This element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents. Inline instruments are associated to instrument loops by using the Association element.

Child elements:

Attributes:

See ‘PlantItem’, no additional attributes are defined.

Example:

<InstrumentLoop ID="XMP_123"><Extent>

<Min X="355" Y="339" Z="0" /><Max X="481" Y="355" Z="0" />

</Extent><SignalLine ... /><SignalLine ... /><SignalLine ... /><ProcessInstrument ... /><ProcessInstrument ... />

</InstrumentLoop>

Attribute Name Required Description

Value Y The bore size

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

ProcessInstrument 0..* An off-line instrument that is part of this set.

SignalLine 0..*

SignalConnectorSymbol 0..*

Connection 0..*

12.19:55© 2011 AVEVA Solutions Ltd

Page 680: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• KnotMultiplicitiesChild elements:

Attributes:

None

Example:

<KnotMultiplicities><Multiplicity>4</Multiplicity><Multiplicity>4</Multiplicity>

</KnotMultiplicities>

• KnotThis is defined as an any but should be considered to be of type xsd:integer.

Child elements :

None

Attributes:

None

Example:<Knot>1</Knot>

• Knots

Child elements:

• LineA linear geometry defined by two points.

Child elements:

Element Name Cardinality Description

Multiplicity 1..*

Element Name Cardinality Description

Knot 1..*

Element Name Cardinality Description

Presentation 1 This defines the drawing style to be used for the ellipse.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

12.19:56© 2011 AVEVA Solutions Ltd

Page 681: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

None

Example:

<Line><Presentation LineWeight="1" LineType="Solid"

Color="red" R="1" G="0" B="0" />

<Extent><Min X="831" Y="502.6" Z="0" /><Max X="841" Y="502.6" Z="0" />

</Extent><Coordinate X="841" Y="502.6" Z="0" /><Coordinate X="831" Y="502.6" Z="0" />

</Line>

• LocationA Location element matches the definition of a Coordinated, it is a Tuple of ordinates denoting a location in the drawing plane. For 2D drawings the Z ordinates should always be 0.

Child elements:

None

Attributes:

Example:<Location X="112" Y="106" Z="0" /><Location X="112" Y="110" />

• ManufacturerThe manufacturer responsible for producing the item

Child elements:

None

Attributes:

Coordinate 2 The coordinates defining the start and end of the line.

GenericAttributes 0..* A geometric primitive

Element Name Cardinality Description

Attribute Name Required Description

X Y The X Axis ordinate as a double

Y Y The Y Axis ordinate as a double

Z N The Z Axis ordinate as a double, If not present this defaults to 0.0

12.19:57© 2011 AVEVA Solutions Ltd

Page 682: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

None

Example:<Manufacturer>My company</Manufacturer>

• MaterialThe name of the Material used to construct the item

Child elements:

None

Attributes:

None

Example:<Material>Copper</Material>

• MaterialDescriptionA description of the material relating to an item

Child elements:

None

Attributes:

None

Example:<MaterialDescription>Some descriptive text</

MaterialDescription>

• MaxMaximum coordinates for an Extent element

Child elements:

None

Attributes:

Example:<Max X="236.78321894" Y="194.01149803" Z="0" />

Attribute Name Required Description

X Y X axis value denoting the maximum X value for all geometric descendants of ../..

Y Y Y axis value denoting the maximum Y value for all geometric descendants of ../..

Z Y Z axis value denoting the maximum Z value for all geometric descendants of ../.. For 2D drawings this should always be 0

12.19:58© 2011 AVEVA Solutions Ltd

Page 683: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• MaximumDesignPressureThe maximum design pressure for an item.

Child elements:

None

Attributes:

Example:

<MaximumDesignPressure Value="12" />

<MaximumDesignPressure Value="35" Units="bar" />

• MaximumDesignTemperatureThe maximum design temperature for an item.

Child elements:

None

Attributes:

Example:

<MaximumDesignTemperature Value="12" />

<MaximumDesignTemperature Value="35" Units="DegreeCelsius" />

• MaximumOperatingPressureThe maximum operating pressure for an item.

Child elements:

None

Attribute Name Required Description

Value Y The maximum design pressure

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The maximum design temperature

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

12.19:59© 2011 AVEVA Solutions Ltd

Page 684: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<MaximumOperatingPressure Value="12" /><MaximumOperatingPressure Value="35" Units="bar" />

• MaximumOperatingTemperatureThe maximum operating temperature for an item.

Child elements:

None

Attributes:

Example:

<MaximumOperatingTemperature Value="12" /><MaximumOperatingTemperature Value="35" Units="DegreeCelsius"

/>

• MinChild elements:

None

Attributes:

Attribute Name Required Description

Value Y The maximum pressure

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The maximum temperature

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

X Y X axis value denoting the minimum X value for all geometric descendants of ../… This is a double

12.19:60© 2011 AVEVA Solutions Ltd

Page 685: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:<Min X="199.6153088" Y="155.02299606" Z="0" />

• MinimumDesignPressureThis is the minimum design pressure for an item.

Child elements:

None

Attributes:

Example:

<MinimumDesignPressure Value="12" /><MinimumDesignPressure Value="35" Units="bar" />

• MinimumDesignTemperatureThis is the minimum design temperature for an item.

Child elements:

None

Attributes:

Example:

<MinimumDesignTemperature Value="12" /><MinimumDesignTemperature Value="35" Units="DegreeCelsius" />

Y Y Y axis value denoting the minimum Y value for all geometric descendants of ../.. This is a double

Z Y Z axis value denoting the minimum Z value for all geometric descendants of ../.. This is a double. For 2D drawings this should always be 0.

Attribute Name Required Description

Attribute Name Required Description

Value Y The minimum design pressure as a double.

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The minimum design temperature as a double.

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

12.19:61© 2011 AVEVA Solutions Ltd

Page 686: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• MinimumOperatingPressureThis is the minimum operating pressure for an item.

Child elements:

None

Attributes:

Example:

<MinimumOperatingPressure Value="12" /><MinimumOperatingPressure Value="35" Units="bar" />

• MinimumOperatingTemperatureThis is the minimum operating temperature for an item.

Child elements:

None

Attributes:

Example:

<MinimumOperatingTemperature Value="12" />

<MinimumOperatingTemperature Value="35" Units="DegreeCelsius"/>

• ModelNumberString element detailing the model number for a component.

Child elements:

None

Attributes:

None

Example:<ModelNumber>A485798347-BjiOM-9347</ModelNumber>

Attribute Name Required Description

Value Y The minimum pressure as a double.

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The minimum temperature as a double.

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

12.19:62© 2011 AVEVA Solutions Ltd

Page 687: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• MultiplicityThis is defined as an any but should be considered to be of type xsd:integer.

Child elements:

None

Attributes:

None

Example:<Multiplicity>4</Multiplicity>

• NominalDiameterThis is the internal bore for an item.

Child elements:

None

Attributes:

Example:

<NominalDiameter Value="4" /><NominalDiameter Value="200" Units="mm" />

• NormalDesignPressureDesign pressure of an item under normal conditions.

Child elements:

None

Attributes:

Example:

<NormalDesignPressure Value="4" /><NormalDesignPressure Value="3" Units="barg" />

Attribute Name Required Description

Value Y The bore size as a double

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The pressure value as a double

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

12.19:63© 2011 AVEVA Solutions Ltd

Page 688: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• NormalDesignTemperatureDesign temperature of an item under normal conditions.

Child elements:

None

Attributes:

Example:

<NormalDesignTemperature Value="52" /><NormalDesignTemperature Value="80" Units="DegreeCelsius" />

• NormalOperatingPressureOperating pressure of an item under normal conditions.

Child elements:

None

Attributes:

Example:

<NormalOperatingPressure Value="4" /><NormalOperatingPressure Value="3" Units="barg" />

• NormalOperatingTemperatureOperating temperature of an item under normal conditions

Child elements:

None

Attribute Name Required Description

Value Y The temperature value as a double

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The pressure value as a double

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

12.19:64© 2011 AVEVA Solutions Ltd

Page 689: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<NormalOperatingTemperature Value="52" /><NormalOperatingTemperature Value="80" Units="DegreeCelsius"

/>

• NozzleA Nozzle element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<Nozzle ID="XMP_10" Tag="N1" ComponentClass="FlangedNozzle"><Extent>

<Min X="205.47371879" Y="245.5" Z="0" /><Max X="215" Y="263" Z="0" />

</Extent><Position>

<Location X="215" Y="255" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="-1" Y="0" Z="0" />

</Position><PersistentID Identifier="{A1-51-2003-1_Topology-

NOZZLE-1}" Context="http://www.aveva.com/example/P&amp;ID" /

><Line>

<Presentation LineType="Solid" LineWeight="1" R="0.25" G="0.82" B="0.15" />

<Extent><Min X="211" Y="255" Z="0" />

Attribute Name Required Description

Value Y The temperature value as a double

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

NozzleType 0..1

NominalDiameter 0..1 Internal nominal bore of nozzle

Height 0..1 Height of Nozzle on the Equipment

12.19:65© 2011 AVEVA Solutions Ltd

Page 690: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Max X="215" Y="255" Z="0" /></Extent><Coordinate X="211" Y="255" Z="0" /><Coordinate X="215" Y="255" Z="0" />

</Line>…<NominalDiameter Value="4" />

</Nozzle>

• NozzleTypeThis is a simple element with one attribute and no contents

Child elements:

None

Attributes:

Example:<NozzleType Value="Flanged"/>

• OperatorTypeThis is a free form string element that may be unit qualified.

Child elements:

None

Attributes:

Example:

None

• OutsideDiameterThis is the external diameter of an item.

Child elements:

None

Attribute Name Required Description

Value N One of ‘Welded’, ‘Flanged’ or ‘Elbow’. This defaults to ‘Flanged’ if the Value attribute isn’t present.

Attribute Name Required Description

Units N This may contain any of the permitted units types See Units.

12.19:66© 2011 AVEVA Solutions Ltd

Page 691: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<OutsideDiameter Value="4" /><OutsideDiameter Value="200" Units="mm" />

• PConnectionPointsSee Issues.

• PersistentIDThe PersistentID element contains a source system identifier for an object that remains consistent between exports of a drawing. A PersistentID is made up of two components the identifier and its scope.

A PersistentID should be the same for an object that appears on multiple drawings where it is practicable to do this. If this cannot be achieved the T, if present, will be used by P&ID Manager for rationalising objects.

Child elements:

None

Attributes:

Example:

<PersistentID

Attribute Name Required Description

Value Y The external diameter measurement as a double

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Identifier Y The persistent identifier for an XML element. The Identifier must be unique within the set of XML files that may interact directly or indirectly with this drawing for the stated context. This a free form string type, see Character encoding.

Context N This scopes a persistent identifier. In this way an item may have different Identifiers for different systems/contexts and each identifier may be represented. Ideally this would be encoded as a URI. For example http://www.aveva.com/P&ID Designer/ProjectName.

12.19:67© 2011 AVEVA Solutions Ltd

Page 692: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Identifier="{A1-51-2003-1_Topology-NOZZLE-1}" Context="http://www.aveva.com/example/P&amp;ID" />

• PipeConnectorAn on or off page connector that represents the connectivity of a PipingNetworkSegment across a page boundary. These are contained by the PipingNetworkSegment elements and reference as the segment source or destination.

A PipeConnector element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

See ‘PlantItem’, no Additional attributes

Example:

<PipeConnector ID="XMP_92" Tag="A1-51-2003-3" StockNumber="flag1">

<Presentation LineType="Solid" LineWeight="1" Color="7" R="1" G="1" B="1" />

<Extent … /><Position … /><PersistentID … /><PolyLine … /><Text … /><CrossPageConnection … />

</PipeConnector>

• PipeFlowArrowThis element is an annotation primitive to represent the direction of flow of a PipingNetworkSegment.

A PipeFlowArrow element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

See ‘PlantItem’, no additional elements

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<PipeFlowArrow ID="XMP_29" ><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" />

Element Name Cardinality Description

CrossPageConnection 0..1 Information describing the matching criteria for the PipeConnector that is connected to this one.

12.19:68© 2011 AVEVA Solutions Ltd

Page 693: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Extent><Min X="671" Y="148" Z="0" /><Max X="673" Y="152" Z="0" />

</Extent><Position>

<Location X="672" Y="148" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="0" Y="1" Z="0" />

</Position><PolyLine NumPoints="42">

<Presentation LineType="Solid" LineWeight="1" Color="7" R="1" G="1" B="1" />

<Extent><Min X="671" Y="148" Z="0" /><Max X="673" Y="152" Z="0" />

</Extent><Coordinate X="671" Y="152" Z="0" /><Coordinate X="672" Y="148" Z="0" /><Coordinate X="673" Y="152" Z="0" /><Coordinate X="671" Y="152" Z="0" />

</PolyLine></PipeFlowArrow>

• PipingNetworkSystemA PipingNetworkSystem contains the information for a physical PipingNetworkSystem in the plant or a section thereof as contained within a module. The PipingNetworkSystem contains all of the PlantItems that belong to it. A PipingNetworkSystem may have multiple sources and multiple destinations.'

A PipingNetworkSystem element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Element Name Cardinality Description

NominalDiameter 0..1

InsideDiameter 0..1

OutsideDiameter 0..1

StartDiameter 0..1

EndDiameter 0..1

NormalDesignPressure 0..1

MinimumDesignPressure 0..1

MaximumDesignPressure 0..1

NormalDesignTemperature 0..1

12.19:69© 2011 AVEVA Solutions Ltd

Page 694: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<PipingNetworkSystem ID="PLINE_1"><Extent ... /><PersistentID ... /><NominalDiameter ... /><MinimumDesignPressure ... /><MaximumDesignPressure ... /><PipingNetworkSegment ... /><PipingNetworkSegment ... /><PipingNetworkSegment ... /><SpecificationBreak ... />

</PipingNetworkSystem>

MinimumDesignTemperature

0..1

MaximumDesignTemperature

0..1

NormalOperatingPressure 0..1

MinimumOperatingPressure

0..1

MaximumOperatingPressure

0..1

TestPressure 0..1

NormalOperatingTemperature

0..1

MiniumumOperatingTemperature

0..1

MaximumOperatingTemperature

0..1

WallThickness 0..1

Connection 0..* Not used as connectivity should be represented by each contained PipingNetworkSegment.

PipingNetworkSegment 0..* The segments that make up the PipingNetworkSystem

SpecificationBreak 0..* Points at which changes occur in the pipe specification. This causes a break in the segment.

Element Name Cardinality Description

12.19:70© 2011 AVEVA Solutions Ltd

Page 695: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• PipingComponentThis represents a physical component that is common to piping systems.

A PipingComponent element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

Example:

<PipingComponent ID="PipeTee_5" ComponentClass="PipeTee"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="112" Y="182" Z="0" /><Max X="112" Y="182" Z="0" />

</Extent><Position>

<Location X="112" Y="182" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><PersistentID … />

Element Name Cardinality Description

PipingComponent 0..* Contained PipingComponent.

ConnectionType 0..1

NominalDiameter 0..1

InsideDiameter 0..1

None Outside Diameter

0..1

OperatorType 0..1

WallThickness 0..1

FabricationCategory 0..1

Attribute Name Required Description

ConnectionType N This is a free text string and has no defined syntax. See Character encoding

Rating N This is a free text string and has no defined syntax. See Character encoding

Standard N This is a free text string and has no defined syntax. See Character encoding

ISOSymbol N This is a free text string and has no defined syntax. See Character encoding

12.19:71© 2011 AVEVA Solutions Ltd

Page 696: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<ConnectionPoints NumPoints="4" FlowIn="1" FlowOut="2" … />

</PipingComponent>

• PipingNetworkSegmentA PipingNetworkSegment is a subsection of a PipingNetworkSystem where the engineering parameters are common. A PipingNetworkSegment will start at a Nozzle, SpecificationBreak or the downstream end of a Reducer or Tee and end at a Nozzle, SpecificationBreak, Reducer, Tee or an open pipe. For a P&ID it can also start or end with a PipeConnector. It will contain one or more CenterLine, PipingComponent, Equipment and ProcessInstrument elements. For a P&ID it is the CenterLines that join the successive components together and these should be considered in the same way as the other symbols and all must occur in the order head to tail.

A PipingNetworkSegment element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

PipeConnectors representing on and off page connectivity are contained by the PipingNetworkSegment. See for details of PipingNetworkSegment connectivity.

Child Elements:

Element Name Cardinality Description

NominalDiameter 0..1

InsideDiameter 0..1

None Outside Diameter

0..1

StartDiameter 0..1

EndDiameter 0..1

NormalDesignPressure 0..1

MinimumDesignPressure 0..1

MaximumDesignPressure 0..1

NormalDesignTemperature 0..1

MinimumDesignTemperature

0..1

MaximumDesignTemperature

0..1

NormalOperatingPressure 0..1

MinimumOperatingPressure

0..1

MaximumOperatingPressure

0..1

TestPressure 0..1

12.19:72© 2011 AVEVA Solutions Ltd

Page 697: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<PipingNetworkSegment ID="XMP_86" Tag="B-902" Specification="A3B">

<Extent><Min X="227" Y="118" Z="0" /><Max X="337" Y="211" Z="0" />

</Extent><PersistentID Identifier="{A1-51-2003-1_Topology-

SEGMENT-1}"Context="http://www.aveva.com/example/P&amp;ID" /

><Connection FromID="XMP_73" ToID="XMP_87" ToNode="2" /><NominalDiameter Value="4" /><PipeFlowArrow ID="XMP_78" … /><CenterLine NumPoints="3">

<Presentation LineType="Solid" LineWeight="1" Color="7" R="1" G="1" B="1" />

<Extent>

NormalOperatingTemperature

0..1

MinimumOperating Temperature

0..1

MaximumOperatingTemperature

0..1

WallThickness 0..1

Connection 0..* This states the head and tail connectivity of this segment.

PipingNetworkSegment 0..* The segments that make up the PipingNetworkSystem

SpecificationBreak 0..* Points at which changes occur in the pipe specification. This causes a break in the segment.

CenterLine 0..*

Equipment 0..*

PipingComponent 0..*

ProcessInstrument 0..*

PipeConnector 0..*

PipeFlowArrow 0..*

Element Name Cardinality Description

12.19:73© 2011 AVEVA Solutions Ltd

Page 698: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Min X="227" Y="118" Z="0" /><Max X="227" Y="132" Z="0" />

</Extent><Coordinate X="227" Y="118" Z="0" /><Coordinate X="227" Y="132" Z="0" /><Coordinate X="291" Y="132" Z="0" />

</CenterLine><PipingComponent ID="XMP_87" ComponentClass="PipeTee" …

/></PipingNetworkSegment>

• PlantAreaIn the P&ID content of an XML file this is just an object that may be used to represent the name and attributes of named part(area) of a plant. A plant Area is not permitted to contain model elements but may be referenced to associated segments, Equipment etc with a named PlantArea.

A PlantArea element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

See ‘PlantItem’, no additional elements

Attributes:

Example:

<PlantArea Name="Area-42"><Extent .. /><Association ../><Association ../><Association ../>

</PlantArea>

• PlantInformationThis element collects the metadata for a PlantModel. The Date and Time attributes should be the Date and Time of the XML file creation.

Child elements:

Attribute Name Required Description

Name N A string representing the name of the area. See Character encoding.

Element Name Cardinality Description

UnitsOfMeasure 1 Defines the default units of measure for the file.

12.19:74© 2011 AVEVA Solutions Ltd

Page 699: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<PlantInformation SchemaVersion="3.1.2" OriginatingSystem="VPEPID" ModelName="http://www.aveva.com/P&amp;ID/example"Date="2006-12-12" Time="16:43:23" Is3D="no" Units="Millimetre" Discipline="PID"><UnitsOfMeasure Distance="Inch" />

</PlantInformation>

• PlantItemThis element is a base abstract type of many elements within an XML file, it defines the common elements and attributes for these items.

Child elements:

Attribute Name Required Description

SchemaVersion Y Fixed value of ‘3.1.2’

OriginatingSystem Y Free form string. See Character encoding

ModelName N Free form string. See Character encoding

Date Y XML date of the format YYYY-MM-DD

ProjectName N Free form string. See Character encoding

ProjectCode N Free form string. See Character encoding

ProjectDescription N Free form string. See Character encoding

CompanyName N Free form string. See Character encoding

Time Y XML time type, assumed UTC unless zone qualified

Is3D Y Fixed value of ‘no’

Units Y The distance units of measure for the geometry in the file.

Discipline Y Fixed value of ‘PID’

Element Name Cardinality Description

Presentation 0..1

Extent 1

PersistentID 0..*

Position 1

Scale 0..1

Surface 0..*

12.19:75© 2011 AVEVA Solutions Ltd

Page 700: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Circle 0..*

CompositeCurve 0..*

Ellipse 0..*

Line 0..*

Polyline 0..*

Shape 0..*

TrimmedCurve 0..*

BsplineCurve 0..*

GeometricPrimitives 0..*

ConnectionPoints 0..1

PConnectionPoints 0..1

Text 0..*

Identifier 0..*

Description 0..1

Weight 0..1

Material 0..1

MaterialDescription 0..1

ModelNumber 0..1

Supplier 0..1

Manufacturer 0..1

GenericAttributes 0..*

Association 0..*

History 0..1

Attribute Name Required Description

ID Y The sequential ID if the item in the file. Of the form ‘XMP_nnn’ where n is the sequential number as an integer. E.g. XMP_22. See ID

Tag N See Tag

Specification N See Specification

StockNumber N See StockNumber

ComponentClass N See ComponentClass

Element Name Cardinality Description

12.19:76© 2011 AVEVA Solutions Ltd

Page 701: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

N/A since the type is abstract

• PointA geometric primitive representing a one dimensional geometry.

Child elements:

Attributes:

Example:

<Point><Presentation LineType="Solid" LineWeight="1"

Color="22" R="0.79" G="0.239" B="0.087" /><Location X="714.387976347" Y="261.753285151" Z="0" />

</Point>

• PolyLineGeometric curve primitive detailing a polyline. The interpolation between each coordinate is linear.

Child elements:

ComponentName N See ComponentName

ComponentType N See ComponentType

Revision N See Revision

Status N See Status

Attribute Name Required Description

Element Name Cardinality Description

Presentation 1 The style used to draw the point.

Location 1 The point coordinate

GenericAttributes 0..* Any application attributes for this point

Attribute Name Required Description

IsVisible N Valid values: ‘true’, ‘false’, ‘1’ or ‘0’. Set to ‘false’ or ‘0’ if this point should not be drawn.

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the line. The drawing behaviour is undefined if the Presentation element is missing.

12.19:77© 2011 AVEVA Solutions Ltd

Page 702: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<PolyLine NumPoints="2"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="77" Y="463" Z="0" /><Max X="646" Y="463" Z="0" />

</Extent><Coordinate X="77" Y="463" Z="0" /><Coordinate X="646" Y="463" Z="0" />

</PolyLine>

• PositionThis defines the place where an items origin is on a P&ID drawing. This is in effect the location of the items symbol. The Axis and Reference attributes are used to define the coordinate orientation in 3D space. The drawing is considered to be on the plane of Z=0.

Child elements:

Attributes:

None

Example:

<Position><Location X="716.06" Y="268.76" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position>

• PresentationThe element defines a styles used to draw geometric and textual content. Whle all attributes are defined as optional in the schema the R, G, B, LineWeight and LineType attributes are expected for all geometric primitives, otherwise the behaviour is undefined.

Child elements:

None

Extent 1 The minimum bounding geometry of the element and its descendants

Coordinate 1..* The coordinates defining the line primitive

Attribute Name Required Description

NumPoints Y The number of child Coordinate elements.

Element Name Cardinality Description

12.19:78© 2011 AVEVA Solutions Ltd

Page 703: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<Presentation LineType="Solid" LineWeight="2mm" Color="22" R="0.8" G="0.25" B="0.1" />

• ProcessInstrumentThis represents a physical instrument that is common to piping systems.

Attribute Name Required Description

Layer N Name of the layer in which the graphical elements resides. This has no functional semantics associated with it.

Color N A lookup in a color index. This isn’t to be used for P&ID Manager P&ID files.

LineType N One of the numbers or names from the following (Object Model document v2.2):-

0 Solid 1 Dotted 2 Dashed 3 Long Dash 4 Long Dash + Short Dash, CenterLine 5 Short Dash 6 Long Dash + Short Dash + Short Dash 7 Dash + Short Dash

LineWeight N <real>

or

<real><units>

or

<real><space><units>

Where:-

<real> is an real value. <space> is a space character (&#20;) <units> is a distance units from Units If the value isn’t qualified with units then the behaviour is undefined.

R N 0 to 1 (double) 1 = maximum intensity of Red component.

G N 0 to 1 (double) 1 = maximum intensity of Green component.

B N 0 to 1 (double) 1 = maximum intensity of blue component.

12.19:79© 2011 AVEVA Solutions Ltd

Page 704: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

A ProcessInstrument element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<ProcessInstrument ID="XMP_33" Tag="LT-117" ComponentClass="LevelTransmitter"><Extent>

<Min X="710" Y="258" Z="0" /><Max X="726" Y="274" Z="0" />

</Extent><Position>

<Location X="718" Y="266" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><Circle Radius="8" … /><Text … />

</ProcessInstrument>

• RatingThis is a unit qualified string value to describe the rating of an item.

Child elements:

None

Element Name Cardinality Description

PlantItem 0..* Contained PipingComponent.

NominalDiameter 0..1

InsideDiameter 0..1

None Outside Diameter

0..1

OperatorType 0..1

WallThickness 0..1

12.19:80© 2011 AVEVA Solutions Ltd

Page 705: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:<Rating Value="5" Units="bar"/>

• ReferenceSee Geometries (Axis and Reference).

Child elements:

None

Attributes:

Example:<Reference X="1" Y="0" Z="0" />

• RemarkA string comment element

Child elements:

None

Attributes:

None

Example:<Remark>WP2134</Remark>

• ScaleThe scale element is used when symbols are drawn from a shape catalogue. The Scale element enables symbols to be rescaled when positioned in a drawing.

Child elements:

None

Attribute Name Required Description

Value Y Maximum safe load

Units N This may be any of the units permitted since the type of measurement isn’t specified. See Units for permitted values, the semantics if Units are not present are unclear.

Attribute Name Required Description

X Y Double

Y Y Double

Z Y Double

12.19:81© 2011 AVEVA Solutions Ltd

Page 706: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:<Scale X="2" Y="2" />

• ShapeThe Shape element defines a closed curve. The interpolation between each coordinate is linear.

Child elements:

Attributes:

Example:

<Shape NumPoints="4" Filled="Solid" ><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="77" Y="463" Z="0" /><Max X="646" Y="534" Z="0" />

</Extent><Coordinate X="77" Y="463" Z="0" /><Coordinate X="77" Y="534" Z="0" /><Coordinate X="646" Y="463" Z="0" />

Attribute Name Required Description

X Y X scale factor

Y Y Y scale factor

Z N Z scale factor

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the line. The drawing behaviour is undefined if the Presentation element is missing.

Extent 1 The minimum bounding geometry of the element and its descendants

Coordinate 4..* The coordinates defining the primitive. The first coordinate should match the last to complete a closed form.

GenericAttributes 0..* Any application specific attributes

Attribute Name Required Description

NumPoints Y The number of child Coordinate elements.

Filled N One of ‘Solid’ or ‘Hatch’ used to specify a fill technique

12.19:82© 2011 AVEVA Solutions Ltd

Page 707: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Coordinate X="77" Y="463" Z="0" /></Shape>

• ShapeCatalogueA Shape Catalogue defines a symbol library for a file. The elements for which the symbols can be defined are currently limited to Equipment and PipingComponent elements only.

See ComponentName for how to reference and name a symbol in the catalogue.

See Scale for how to scale symbols when drawn.

Child elements:

Attributes:

Example:

<ShapeCatalogue Name="Symbols"><Equipment ID="XMP_22" ComponentClass="VerticalPump"

ComponentName="VPump"><Extent … /><Position … />

Element Name Cardinality Description

Equipment 0..* Equipment symbols

PipingComponent 0..* PipingComponent symbols

Nozzle 0..* Nozzle symbols

ProcessInstrument 0..* ProcessInstrument symbols

Component 0..* Component symbols

PipeConnector 0..* PipeConnector symbols

SignalConnectorSymbol 0..* SignalConnector symbols

Attribute Name Required Description

Name Y The name of the symbol catalogue, this is a string attribute.

Version N The version of the symbol set.

Units N The distance units that the symbols are defined in. This affects the size of the symbol with respect to the units defined by the PlantInformation/UnitsOfMeasure/@Distance attribute. i.e if Units is different to the PlantInformation default then the symbol is scaled. See the distance section of Units for valid values.

Date N The date the symbol library was created/modified.

12.19:83© 2011 AVEVA Solutions Ltd

Page 708: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<PersistentID … /><Circle … />…

</Equipment><ShapeCatalogue>

• SignalConnectorSymbol An on or off page connector that represents the connectivity of a SignalLine across a page boundary.

A SignalConnectorSymbol element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<SignalConnectorSymbol ID="XMP_92"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent … /><Position … /><PersistentID … /><PolyLine … /><Text … /><CrossPageConnection … />

</SignalConnectorSymbol>

• SignalLineA connection between two instruments carrying instrumentation signals.

A SignalLine element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Element Name Cardinality Description

CrossPageConnection 0..1 Information describing the matching criteria for the SignalConnector that is connected to this one.

Element Name Cardinality Description

CenterLine 0..* The graphical representation of the connectivity.

ProcessInstrument 0..* Instruments contained in this signal line.

Connection 0..1 The connectivity details of this SignalLine

SignalConnectorSymbol 0..* An off/on page connector for signal lines.

12.19:84© 2011 AVEVA Solutions Ltd

Page 709: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<SignalLine ID="XMP_86" Tag="B-902" ><Extent>

<Min X="227" Y="118" Z="0" /><Max X="337" Y="211" Z="0" />

</Extent><PersistentID Identifier="{A1-51-2003-1_Topology-

SIGNALLINE-1}"Context="http://www.aveva.com/example/P&amp;ID" /

><Connection FromID="XMP_73" ToID="XMP_87" ToNode="2" /><NominalDiameter Value="4" /><CenterLine NumPoints="3">

<Presentation LineType="Solid" LineWeight="1" Color="7" R="1" G="1" B="1" />

<Extent><Min X="227" Y="118" Z="0" /><Max X="227" Y="132" Z="0" />

</Extent><Coordinate X="227" Y="118" Z="0" /><Coordinate X="227" Y="132" Z="0" /><Coordinate X="291" Y="132" Z="0" />

</CenterLine><ProcessInstrument ID="XMP_87" … />

</SignalLine>

• SpecificationBreakThis represents the point at which there is a change in specification of the piping. See Issues.

A SpecificationBreak element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

A SpecificationBreak may only be contained by a PipingNetworkSystem element.

Child elements :

(See ‘PlantItem’) No Additional elements

Attributes :

(See ‘PlantItem’) No Additional attributes

Example :

<SpecificationBreak ID="XMP_34"><Description>Change in Insulation</Description>

</SpecificationBreak>

12.19:85© 2011 AVEVA Solutions Ltd

Page 710: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• StartDiameterThis is the internal bore for a segment or a PipingNetworkSystem at its source.

Child elements:

None

Attributes:

Example:

<StartDiameter Value="4" /><StartDiameter Value="200" Units="mm" />

• StringA string value used to annotate a drawing. Each element represents a single line of text.

Child elements:

None

Attributes:

Example:

<String Value="1. my text annotation"/><String Value="2. a second line of text"/>

• SupplierThis is the name of the supplier for an item.

Child elements:

None

Attributes:

None

Example:<Supplier>My supplier</Supplier>

Attribute Name Required Description

Value Y The bore size

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The string value

Units N Any units associated with the string value, not sure how to use this.

12.19:86© 2011 AVEVA Solutions Ltd

Page 711: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• SurfaceSee Issues.

• TestPressureThe pressure that should be used to test an item

Child elements:

None

Attributes:

Example:<TestPressure Value="60" Units="bar"/>

• TextThis defines the textual annotation for a drawing. The text may be provided in an attribute, referenced using attributes on this item, referenced on attributes of another item or provided as a set of String elements.

Child elements:

Attribute Name Required Description

Value Y The pressure

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

Presentation 1 The style to use to draw the text.

Extent 1 The minimum bounding rectangle around the text.

Position 1 The position of the text

String 0..* Used when the text contains a line break.

GenericAttributes 0..* Any application specific attributes, this could include attributes that contain the text content to write.

12.19:87© 2011 AVEVA Solutions Ltd

Page 712: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Attribute Name Required Description

NumLines N The number of text lines being represented. If not present then a value of 1 is assumed.

String N If present this is the text to be drawn. If the text contains a line break then it should be split into the String child elements instead of being in the attribute or the line break character replaced with an appropriate character reference.

Font Y The font family name to use.

Justification The location of Position within the Text to be written. Where the text is on multiple lines then Justification denotes the location of Position for the first line of text.

One of the following:

LeftTop LeftCenter LeftBottom CenterTop CenterCenter CenterBottom RightTop RightCenter RightBottom

Defaults to LeftBottom if not provided.

Width Y The full width of the Text string once rendered

Height Y The full height of the Text string once rendered

TextAngle This is the angle that the base line of the text string makes with the positive X axis measured anticlockwise in degrees.

SlantAngle This is the angle, in degrees, of slant of the text characters measured clockwise from the positive Y axis. E.g. for the character I it is the angle that the vertical stroke makes with the positive Y axis.

ItemID If provided then the text string is to be constructed from the attributes of another element. The ID may be provided as the ID of the element, the PersistentID/@Identifier or the Tag of the element. See Tag Referencing.

12.19:88© 2011 AVEVA Solutions Ltd

Page 713: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<Text String="4&quot;-B-902-A3B" Font="romans" Justification="CenterCenter" Width="19.2"Height="2.5" TextAngle="90" SlantAngle="0"><Presentation LineType="Solid" LineWeight="1"

Color="160" R="0" G="0.4" B="1" /><Extent>

<Min X="331.98850197" Y="154.37335742" Z="0" /><Max X="334.48850197" Y="182.19944438" Z="0" />

</Extent><Position>

<Location X="333.238501971" Y="154.373357424" Z="0" />

<Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Text><Text Font="Arial" Justification="LeftBottom" Width="17.2678"

Height="2.032" TextAngle="90" DependantAttribute="[FluidSystem][OperFluidCode]">

Set If the text is to be obtained from a child of a GenericAttributes element then the set name for the GenericAttributes element may be provided to avoid ambiguity.

DependantAttribute The template for the textual contents if obtaining the text from referenced attributes.

The value of the DependantAttribute can contain a single attribute or a list of Attributes and explicit text. IF a single attribute is referenced it may appear just as the attribute name. Where multiple attributes or explicit text is used the attribute names are contained in square brackets. E.g “[Tagprefix]-[Tagnumber][Tagsuffix]”.

The search order will be the Attributes of the PlantItem, ItemAttributes then GenericAttributes of the Text followed by the GenericAttributes of the parent or the object explicitly identified by the ItemID. The first occurrence of the named Attribute will be used, there is no mechanism for handling multiple attributes of the same name.

Attribute Name Required Description

12.19:89© 2011 AVEVA Solutions Ltd

Page 714: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Presentation Layer="HiddenObjects" LineType="0" LineWeight="0"

Color="Black" R="0" G="0" B="0"/><Extent>

<Min X="262.83575736" Y="344.08495775" Z="0"/><Max X="264.86775736" Y="369.5594541" Z="0"/>

</Extent><Position>

<Location X="264.867757356" Y="344.08495775" Z="0"/>

<Axis X="0" Y="0" Z="1"/><Reference X="1" Y="0" Z="0"/>

</Position></Text>

• TransactionA record of a change to an item

Child elements:

Attributes:

Example:

<Transaction Type="to modify" Date="2007-06-10" Time="10:30:32" CompanyName="My company" Person="Me">

Element Name Cardinality Description

Remark 0..* A comment describing the change.

GenericAttributes 0..* Any application specific attributes

Attribute Name Required Description

Type N One of the following;

to approve to check to copy to create to modify to request to release

Date N A date type (YYYY-MM-DD)

Time N A time type (HH:MM:SS) (See http://www/w3.org for full details including time zones)

CompanyName N A free form string (see Character encoding)

Person N A free form string (see Character encoding)

12.19:90© 2011 AVEVA Solutions Ltd

Page 715: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Remark>Amended Nozzle parameters for new specification</Remark><Remark>WP2134</Remark>

</Transaction>

• TrimmedCurveAn arc based on a circle or ellipse definition

Child elements:

Attributes:

Example:

<TrimmedCurve StartAngle="0" EndAngle="56.251"><Circle Radius="3.175">

<Presentation LineType="Solid" LineWeight="1" R="0.25" G="0.82" B="0.15" />

<Extent><Min X="690.58888896" Y="480.00947926"

Z="0" /><Max X="692" Y="482.64942637" Z="0" />

</Extent><Position>

<Location X="688.825" Y="480.009479262" Z="0" />

<Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position>

Element Name Cardinality Description

Circle 0..1 Only present if Ellipse isn’t present. The base Circle used to define the arc.

Ellipse 0..1 Only present if Circle isn’t present. The base ellipse used to define the arc.

GenericAttributes 0..* Any application specific attributes

Attribute Name Required Description

StartAngle Y The rotation around the circle/ellipse to start the arc from. 0 = up. The direction of the rotation is governed by the Z axis specifier on the geometry. Angle specified in degrees (0-360).

EndAngle Y The rotation around the circle/ellipse to end the arc at. 0 = up. The direction of the rotation is governed by the Z axis specifier on the geometry. Angle specified in degrees (0-360).

12.19:91© 2011 AVEVA Solutions Ltd

Page 716: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

</Circle></TrimmedCurve>

• UnitsOfMeasureThis element specifies the default units of measure for the file for each type of measured value.

Child Elements:

None

Attributes:

Example:<UnitsOfMeasure Distance="Inch" />

• WallThicknessThe thickness of the element construction.

Child elements:

None

Attributes:

Example:<WallThickness Value="4" Units="mm"/>

Attribute Name Required Description

Distance N See Units for permitted distance values. Default value is ‘Millimetre’.

Angle N See Units for permitted angle values. Default value is ‘Degree’.

Temperature N See Units for permitted temperature values. Default value is ‘DegreeCelsius’.

Pressure N See Units for permitted pressure values. Default value is ‘Bar’.

Weight N See Units for permitted weight values. Default value is ‘Kilogram’.

Attribute Name Required Description

Value N The thickness value. Nb this is a string type and so could be represented in many ways.

Units N The units of measure (See Units for permitted values). If not present then this defaults to the units specified by PlantInformation/UnitsOfMeasure.

12.19:92© 2011 AVEVA Solutions Ltd

Page 717: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• WeightThe weight of the item.

Child elements:

None

Attributes:

Example:<Weight Value="6" Units="oz"/>

• WeightsDataChild elements:

Attributes:

None

Example:

<WeightsData><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight>

</WeightsData>

Attribute Name Required Description

Value N The weight value.

Units N The units of measure (See Units for permitted values). If not present then this defaults to the units specified by PlantInformation/UnitsOfMeasure.

Element Name Cardinality Description

ControlPointWeight 0..*

12.19:93© 2011 AVEVA Solutions Ltd

Page 718: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.6 The ISO15926 (Version 3.3.3) Schema Specification

9.6.1 IntroductionThe 3.3.3 version of the ISO15926 schema can only be used to export data that is to be imported by the 12.0 SP5 version of PDMS or later.

If exporting data to previous versions of PDMS (e.g. 12.0 SP4), the 3.2.0 version of the ISO15926 schema must be used. See 9.5: The ISO15926 (Version 3.2.0) Schema Specification.

• NotationWhere the notation ‘…’ is used in examples it implies content that has been omitted due to it not being relevant for the example.

Elements in examples have been abbreviated to <Tag … /> to show structure but limit content.

9.6.2 Model Details

• XML File Document StructureThe document structure is defined in the XML schema for the P&ID profile (See below). An output file that conforms to this document must validate against the profile schema.

The first line of the file must be an XML declaration, for example:

The document is to be encoded using UTF-8.

The root node of a file is a PlantModel element. See the Element Definitions (below) for the definitions of its attribute and element contents.

XML elements are not defined within an XML namespace and so are not namespace qualified.

Elements are not defined within an XML namespace and so are not namespace qualified.

The following class model provides an overview of the significant structural elements contained within a P&ID profile. The arrows indicate and parent/child element relationship in the file. The elements and their attributes are defined in section 4 of this document. Child elements of the ShapeCatalogue element have been omitted for clarity. Geometric and annotation elements have also been omitted.

<?xml version="1.0" encoding="UTF-8" ?>

12.19:94© 2011 AVEVA Solutions Ltd

Page 719: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

12.19:95© 2011 AVEVA Solutions Ltd

Page 720: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• TopologyTwo elements within the file format are used to represent explicit connectivity between engineering components. These elements are:

• Connection - on the PipingNetworkSegment and SignalLine elements• CrossPageConnection - on the PipeConnectorSymbol and SignalConnectorSymbol

elements

- PipingNetworkSegment Topology (Connection element)

Components within a PipingNetworkSegment are considered to be implicitly connected, by their main flow in and flow out connections points, in the order that they are represented in the PipingNetworkSegment. This ordering may differ between a P&ID and 3D model.

Each PipingNetworkSegment is a collection of Components with common engineering properties that define a single process flow. Where there is a junction in the flow or a change of specification the PipingNetworkSegment will terminate and be connected to PipingNetworkSegments for each subsequent flow. Subsidiary flows or connections for the purposes of instrumentation are not considered as terminating conditions for a PipingNetworkSegment

A PipingNetworkSegment, as its upstream or head reference (PipingNetworkSegment/Connection/@FromID), will reference a Nozzle, InstrumentConnection, splitting component (such as a Tee, Wye, Cross, Three Way Valve etc), Reducer, ProcessInstrument or PropertyBreak that it doesn't contain or it will reference a PipeConnectorSymbol that it contains as its first engineering component for connections to other drawings

12.19:96© 2011 AVEVA Solutions Ltd

Page 721: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

A PipingNetworkSegment, as its downstream or tail reference (PipingNetworkSegment/Connection/@ToID), will reference a Nozzle, InstrumentConnection, merging component (such as a Tee, Wye or Cross), ProcessInstrument or PropertyBreak that it doesn't contain or it will reference a splitting component (such as a Tee, Wye or Cross), Reducer or PipeConnectorSymbol that it contains as its last engineering component.

References to contained components by the Connection element, with the exception of PipeConnectorSymbol elements, require a ToNode attribute which references the downstream ConnectionPoint of the component (i.e. the main flow out of the segment).

Components contained by other segments must be referenced using a ToNode or FromNode attribute as appropriate.

References to Nozzle, PipeConnectorSymbol, PropertyBreak and ProcessInstrument elements do not require a ToNode/FromNode attribute.

12.19:97© 2011 AVEVA Solutions Ltd

Page 722: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

The following diagrams demonstrates all permissible PipingNetworkSegment relationships expressed via the Connection element:

- SignalLine Topology (Connection element)

This part of the overall specification has not been clarified.

- Connections across drawings

Connections across drawings are managed by the CrossPageConnection element that is present on PipeConnectorSymbol and SignalConnectorSymbol elements. The connection is expressed by the following:

• DrawingName - Identifying the drawing that the connection is to (optional)• LinkLabel - A unique key used to match with another Connector Symbol (optional)• LinkedPersistentID - The PersistentID of the connected Connector Symbol (optional)

Connections are only valid if:• The matching criteria are met in both directions• The connection elements are of the same type e.g. PipeConnectorSymbol ->

PipeConnectorSymbol

12.19:98© 2011 AVEVA Solutions Ltd

Page 723: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

For Example, the following would be matched if in the appropriate drawing files:

See the Element Definitions for further information.

• Geometries (Axis and Reference)All geometries in a P&ID file are accompanied by Axis and Reference elements. These define rotations around 3 dimensional axis that define how to map the coordinates defined for the item into the target environment. For most 2D drawing work the following values give the expected behaviour (i.e. the coordinates are defined in the 2D drawing plane).

<Axis X="0" Y="0" Z="1"/>

<Reference X="1" Y="0" Z="0"/>

Some curve primitives such as ellipses in XMpLant require more complex use of Axis and Reference in order to define the 2D forms.

The <Axis> value defines a unit vector in 3D space about which an object should rotate. For 2D diagrams nearly all geometries will define this element as <Axis X="0" Y="0" Z="1"/> which denotes a vector aligned with the Z-axis.

The <Reference> element defines what is effectively the rotation about the <Axis> element. When you see the value written as <Reference X="1" Y="0" Z="0"/> it indicates that the X-Axis with which the object's points are defined use the same X-Axis on the output surface/window with which to orientate - in other words no rotation is required when you have the following paired elements;

<Axis X="0" Y="0" Z="1"/>

<Reference X="1" Y="0" Z="0"/>

Common variations include:

Inverted z axis (flip around y axis) : <Axis X="0" Y="0" Z="-1"/>

Rotation about the origin : <Reference X="[cosØ]" Y="[sinØ]" Z="0" />

Where:

[sinØ] - is the sine of the rotation angle

[cosØ] - is the cosine of the rotation angle

The rotation is measured anti-clockwise

<PipeConnectorSymbol ID="id_49" … > <CrossPageConnection DrawingName="905681" LinkLabel="RV90010" /> </PipeConnectorSymbol> <PipeConnectorSymbol ID="id_52" … > <CrossPageConnection DrawingName="905675" LinkLabel="RV90010" /> </PipeConnectorSymbol>

12.19:99© 2011 AVEVA Solutions Ltd

Page 724: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• Character EncodingXMpLant is encoded using UTF-8. This means that most characters used in western languages are encoded using a single byte representation, more complex characters are encoded using either a 2 byte encoding or a numerical substitution.

• TagName ReferencingTagName attributes may be used to reference elements instead of referencing by the ID attribute. The P&ID profile prefers the use of ID referencing as it gives a consistent referencing mechanism that can be used regardless of the presence of a Tag attribute.

If TagName attributes are used then there is a special case for referencing Nozzle elements. In this instance the TagName is only unique within the scope of the containing Equipment element so the Equipment TagName must also be included in the reference. The reference must have the form <EquipmentTagName>-<NozzleTagName> and can only be used where the <NozzleTagName> component doesn't contain a '-' character.

For Example:

Where:

Equipment/@TagName = ‘VP-1234-DNJ09’

Equipment/Nozzle/@TagName = ‘N1’

The reference would be:

VP-1234-DNJ09-N1

• PersistentID ReferencingAs long as the context attribute used to scope PersistentID elements is at least equal in scope to the file scope then PersistentID attributes may be used for cross referencing elements. The PersistentID/@Identifier value is supported in any ItemId attribute. The PersistentID/@Context is not specified when referencing by PersistentID.

9.6.3 Shared Attribute Definitions

• IDThe ID attributes of the elements must conform to XML identity constraints. See http://www.w3.org/TR/2006/REC-xml-20060816/#id for more details. These id values may be used for cross referencing elements and are transient. i.e. these ids are generated for each version of the file and cannot be used to match file contents between two different exports of the same drawing.

For example:

• TagNameThis should contain the full TagName for an item without additional text. This is an xsd:string attribute with no specific validation (see Character encoding for character constraints)

<PipingNetworkSegment ID=”_23” … >

12.19:100© 2011 AVEVA Solutions Ltd

Page 725: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• SpecificationThis is to be the name of the relevant pipe specification for the component. This is a free text field but should only contain the name of the specification.

• StockNumberThis is defined as:

‘A code that will identify a purchasable plant item

‘The StockNumber attribute contains the unique name of this component that can be used to relate to the complete set of information that is contained in the vendor catalogue for the component. This attribute taken with the Specification and NominalDiameter will identify a specific item, fully defining its parameters size and optionally material and all other information available for it.’

This attribute is an xsd:string attribute and has no specific validation or constraints other than those defined in the ‘Character encoding’ section of this document.

• ComponentNameIf present on a component that is inside a ShapeCatalogue element then this is the unique id for the symbol within the file.

If present on a component that is not inside a ShapeCatalogue element then this is the reference to the geometry of the components symbol. The component may have additional annotation defined within it. The symbol referenced may be scaled (See Scale) or rotated (See Geometries (Axis and Reference)) by the Position element.

• ComponentClassThis attribute is the RDL Designation field from the ISO 15926 RDL specification. The value of this field is converted to Camel Case with all spaces removed. Notes : some fields contain characters that must be substituted when written in XML (e.g. ‘&’ characters must be substituted with &amp;). For example:

GATE VALVE -> GateValve

CENTRIFUGAL PUMP -> CentrifugalPump

• ComponentTypeTo be defined.

• RevisionIf known this attribute should contain the revision or version of the item. This has the type of xsd:string and therefore has no specific syntax or format constraints other than those detailed in Character encoding.

• StatusOne of the following values :-

‘Current’ – This implies this is the latest version of an item

‘Deleted’ – This item has been superseded or removed from the drawing.

‘Modified’ – The last change to this item was a modification.

12.19:101© 2011 AVEVA Solutions Ltd

Page 726: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

‘New’ – This is the first version of the item in the drawing.

Items marked as 'Deleted' may be ignored by an import.

• UnitsThe Units attribute is to be taken from the ISO15926 RDL catalogue using the name from the catalogue converted to camel-case. All measurement values such as distances and pressures are either accompanied by their units of measure or defaulted to the value provided on the PlantInformation/UnitsOfMeasure element. The unit of measure for the coordinate geometry is stipulated in the PlantInformation/@Units attribute. The permitted values are as follows:

Angles:

Degree, Radian, deg, rad

Area :

SquareMillimetre, SquareCentimetre, SquareMetre, SquareKilometre, SquareInch, SquareFoot, SquareYard, SquareMile, sq mm, sq cm, sq m, sq km

Distances:

Micron, Millimetre, Centimetre, Decimetre, Metre, Kilometre, Inch, Foot, Yard, Mile, mm, cm, m, km, in, ft, yd

Pressures:

MillinewtonMetreSquared, NewtonMetreSquared, KilonewtonMetreSquared, Picopascal, Micropascal, Millipascal, Pascal, Kilopascal, Megapascal, Gigapascal, Bar, Bara, Barg

Temperatures:

DegreeKelvin, DegreeCelsius, DegreeRankine, DegreeFahrenheit, degC, degF, degK

Volume :

CubicMillimetre, CubicCentimetre, CubicMetre, CubicInch, CubicFeet, CubicYard, cc, litres, gallons, USGallons, barrels

Weight:

Microgram, Milligram, Gram, Kilogram, Megagram, PoundMass, OunceMass, mg, Kg, lb, oz

Note: All values are case sensitive.

9.6.4 Element Definitions• PlantModel• AnnotationItem• Association• Axis• BsplineCurve• CenterLine• Circle• Component• CompositeCurve

12.19:102© 2011 AVEVA Solutions Ltd

Page 727: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• Connection• ConnectionPoints• ConnectionType• ControlPoints• ControlPointWeight• Coordinate• CrossPageConnection• Description• Discipline• Drawing• DrawingBorder• Ellipse• EndDiameter• Equipment• Extent• FabricationCategory• GenericAttribute• GenericAttributes• Height• History• Identifier• IdentifierElement• InsideDiameter• InstrumentComponent• InstrumentConnection• InstrumentLoop• InsulationSymbol• KnotMultiplicities• Knot• Knots• Label• Line• LinkedPersistentID• Location• Manufacturer• Material• MaterialDescription• Max• MaximumDesignPressure• MaximumDesignTemperature• MaximumOperatingPressure• MaximumOperatingTemperature• Min

12.19:103© 2011 AVEVA Solutions Ltd

Page 728: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• MinimumDesignPressure• MinimumDesignTemperature• MinimumOperatingPressure• MinimumOperatingTemperature• ModelNumber• Multiplicity• NominalDiameter• NormalDesignPressure• NormalDesignTemperature• NormalOperatingPressure• NormalOperatingTemperature• Nozzle• NozzleType• OperatorType• OutsideDiameter• PConnectionPoints• PersistentID• PipeConnectorSymbol• PipeFlowArrow• PipingComponent• PipingNetworkSegment• PipingNetworkSystem• PipingSystem• PlantArea• PlantInformation• PlantItem• PolyLine• Position• Presentation• ProcessInstrument• PropertyBreak• Rating• Reference• Remark• Scale• ScopeBubble• Shape• ShapeCatalogue• SignalConnectorSymbol• SignalLine• StartDiameter• String• Supplier

12.19:104© 2011 AVEVA Solutions Ltd

Page 729: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• Surface• System• TestPressure• Text• Transaction• TrimmedCurve• UnitsOfMeasure• WallThickness• Weight• WeightsData

• PlantModelThis is the root node of an XML document and only exists as the root node of an XML file. Other than the first two child elements, PlantInformation and Extent, the ordering of child elements within a PlantModel element is not significant.

There shouldn’t be any need to place graphical elements into a PlantModel element as all drawing annotation such as borders and floating text should be child elements of the drawing element.

While a Position element may be provided is has no attached semantics and is often defaulted to 0,0,0.

Child Elements:

Element Name Cardinality Description

PlantInformation 1 The properties of a plant model This includes properties like its name, modification date, editing system etc. The PlantInformation element must be the first child element of a PlantModel element.

Extent 1 The minimum bounding rectangle that encloses the full graphical contents of the PlantModel instance. The Extent element must be the second child element of a PlantModel element

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A composite geometry

Drawing 1 Metadata and graphical annotation related to the P&ID drawing being represented

Ellipse 0..* A geometric primitive

Equipment 0..* The representation of a piece of plant equipment.

12.19:105© 2011 AVEVA Solutions Ltd

Page 730: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<?xml version="1.0" encoding="UTF-8" ?><PlantModel xmlns:xsi=http://www.w3.org/2001/XMLSchema-instance

xsi:noNamespaceSchemaLocation=".\XMLSchema.xsd"><PlantInformation … /><Extent … /><Drawing … /><ShapeCatalogue … /><Equipment … />…

</PlantModel>

GenericAttributes 0..* Source system properties that relate to the XML file and plant model. These properties may be grouped into many GenericAttributes elements.

InstrumentComponent 0..* An offline instrument

InstrumentLoop 0..* A grouped set of instrument detail

Line 0..* A geometric primitive

PipingNetworkSystem 0..* An Engineering PipingNetworkSystem element

PipingSystem 0..*

PipeLine 0..* An Engineering PipeLine element

PlantArea 0..* A place holder for Area information

PolyLine 0..* A geometric Primitive

Position 0..1 Usually defaulted to 0,0,0 if output.

Presentation 0..* Style information for this object. In this context it has no meaning and should be omitted.

ProcessInstrument 0..* Offline instruments connected to the process line.

Shape 0..* A geometric primitive

ShapeCatalogue 0..* A catalogue of Equipment and PipingComponent symbols.

SignalConnectorSymbol 0..* A connection between drawings for signals

SignalLine 0..* A connection between instruments.

System 0..*

Text 0..* Label primitives

TrimmedCurve 0..* A geometric primitive

Element Name Cardinality Description

12.19:106© 2011 AVEVA Solutions Ltd

Page 731: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• AnnotationItemThis element is a base abstract type of many elements within an XMpLant file, it defines the common elements and attributes for these items.

Child elements:

Attributes:

Element Name Cardinality Description

Presentation 0..1

Extent 1

PersistentID 0..*

Position 1

Scale 0..1

Circle 0..*

CompositeCurve 0..*

ConnectionPoints 0..*

Ellipse 0..*

Line 0..*

PolyLine 0..*

Shape 0..*

TrimmedCurve 0..*

BsplineCurve 0..*

Text 0..*

Description 0..1

GenericAttributes 0..*

History 0..1

Association 0..*

Attribute Name Required Description

ID Y The unique identity for the item in the file. See ID

ComponentClass N See ComponentClass

ComponentName N See ComponentName

ComponentType N See ComponentType

Revision N See Revision

Status N See Status

12.19:107© 2011 AVEVA Solutions Ltd

Page 732: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

N/A since the type is abstract.

• AssociationThe Association element is used to relate engineering items to other resources.

One documented use of this is to relate in-line ProcessInstrument elements with InstrumentLoop elements. In this case each in-line ProcessInstrument element has an Association child element which details the relationship using the Type attribute with a value of ‘is a part of’.

Child elements :

None

Attributes:

Example:

<ProcessInstrument ...><Association Type="is a part of" ItemID="235"/>...

</ProcessInstrument>

• AxisSee Geometries (Axis and Reference).

Child elements :

None

Attribute Name Required Description

Type Y The meaning/semantics of the relationship.

ItemID N The ID or PersistentID/@Identifier attribute value of the item being referenced.

TagName N The TagName attribute value of the item being referenced. (See TagName Referencing)

Name N The Name attribute value of the item being referenced.

URI N A URI identifying an associated resource

Context N If omitted then the resource is assumed to be part of the model in the same file. If you want to state the context as the current model then use the value ‘XML’.

12.19:108© 2011 AVEVA Solutions Ltd

Page 733: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes :

Example:

<Axis X="0" Y="0" Z="1" />

• BsplineCurveGeometric curve primitive detailing a B spline.

Child elements:

Attributes:

Attribute Name Required Description

X Y

Y Y

Z Y

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the Bspline. The drawing behaviour is undefined if the Presentation element is missing.

Extent 1 The minimum bounding geometry of this element and its descendants

ControlPoints 1

KnotMultiplicities 0..1

Knots 0..1

WeightsData 0..1

GenericAttributes 0..1 Any application specific attributes relating to the Bspline

Attribute Name Required Description

Degree Y

CurveType Y One of the following : 'BsplineCurve', 'BsplineCurveWithKnots' or 'RationalBsplineCurve'.

CurveForm N One of the following : 'PolyLine', 'CircularArc', 'EllipticArc', 'ParabolicArc' or 'HyperbolicArc'

NumControlPoints Y x

NumKnots N x

Closed N 'true' or 'false'

SelfIntersect N 'true' or 'false'

12.19:109© 2011 AVEVA Solutions Ltd

Page 734: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

BsplineCurve Degree="3" CurveType="BsplineCurveWithKnots" NumControlPoints="4" NumKnots="8"><Presentation Layer="" Color="-32363" LineType="0"

LineWeight="1" R="0.67" G="0.38" B="0"/><Extent>

<Min X="10241.64" Y="10283.399" Z="40.9999850090838"/>

<Max X="10241.64" Y="10283.399" Z="41.0000151701423"/>

</Extent><ControlPoints>

<Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/>

</ControlPoints><Knots>

<Knot>0</Knot><Knot>1</Knot>

</Knots><KnotMultiplicities>

<Multiplicity>4</Multiplicity><Multiplicity>4</Multiplicity>

</KnotMultiplicities><WeightsData>

<ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight>

</WeightsData>

</BsplineCurve>

• CenterLineGeometric curve primitive detailing the line geometry between the components of a PipingNetworkSegment. A CenterLine element is used to imply the presence of tubing. The interpolation between each coordinate is linear.

Child elements:

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the line. The drawing behaviour is undefined if the Presentation element is missing.

Extent 1 The minimum bounding geometry of the CenterLine element and its descendants

Coordinate 1..* The coordinates defining the line primitive

12.19:110© 2011 AVEVA Solutions Ltd

Page 735: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<CenterLine NumPoints="2" ID="ID_12345"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="77" Y="463" Z="0" /><Max X="646" Y="463" Z="0" />

</Extent><Coordinate X="77" Y="463" Z="0" /><Coordinate X="646" Y="463" Z="0" />

</CenterLine>

• CircleA geometric primitive describing a circle.

Child elements:

Attributes:

Example:

PersistentID 0..*

GenericAttributes 0..* Any application specific attributes relating to the tube/CenterLine

Attribute Name Required Description

NumPoints Y The number of child Coordinate elements.

ID N The unique identity of the item in the file. See ID

Element Name Cardinality Description

Element Name Cardinality Description

Presentation 1 The style to use when drawing the circle

Extent 1 The minimum bounding geometry of the circle

Position 1 The location of the circles centre

GenericAttributes 0..* Any application attributes relating to the circle

Attribute Name Required Description

Radius Y The radius of the circle to draw

Filled N One of ‘Solid’ or ‘Hatch’. If not present the circle is not filled.

12.19:111© 2011 AVEVA Solutions Ltd

Page 736: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Circle Radius="8"><Presentation LineType="Solid" LineWeight="1"

Color="22" R="0.79" G="0.239" B="0.087" />

<Extent><Min X="710" Y="258" Z="0" /><Max X="726" Y="274" Z="0" />

</Extent><Position>

<Location X="718" Y="266" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Circle>

• ComponentUsed to group geometric and text primitives within a Drawing element. This inherits all elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents..

Child elements:

Attiribute :

See ‘PlantItem’, no additional attributes are defined.

Example:

<Component ID="ID_12"><Extent>

<Min X="199.6153088" Y="155.02299606" Z="0" /><Max X="236.78321894" Y="194.01149803" Z="0" />

</Extent><Position>

<Location X="221" Y="182" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position>…<Text … /></Component>

• CompositeCurveA collection of geometric curve primitives

Element Name Cardinality Description

Component 0..*

12.19:112© 2011 AVEVA Solutions Ltd

Page 737: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

None

Example:

<CompositeCurve><Presentation LineType="Solid" LineWeight="1"

Color="22" R="0.79" G="0.239" B="0.087" />

<Extent><Min X="714.38797635" Y="260.50328515" Z="0" /><Max X="720.62485791" Y="263.00328515" Z="0" />

</Extent><Circle ... /><Circle ... /><PolyLine ... />

</CompositeCurve>

• ConnectionThis element is used to describe the flow connectivity between elements. The source of the flow is defined using the attributes FromID and FromNode while the flow destination is defined using ToID and ToNode. A connection element and its attributes are not mandatory but must be present to represent the topology of a network. If the FromID/ToID attributes reference a Nozzle, PipeConnectorSymbol or PropertyBreak element then the FromNode/ToNode attributes are not required.

See ConnectionPoints for details on what is being referenced.

Element Name Cardinality Description

Presentation 0..1 The Presentation element has no purpose in this context.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A geometric primitive

Ellipse 0..* A geometric primitive

Line 0..* A geometric primitive

Polyline 0..* A geometric primitive

Shape 0..* A geometric primitive

TrimmedCurve 0..* A geometric primitive

GenericAttributes 0..* Any application specific properties relating to the Drawing.

12.19:113© 2011 AVEVA Solutions Ltd

Page 738: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

None

Attributes:

Example:

<PipingNetworkSegment … >…<Connection FromID="ID_73" ToID="ID_4" ToNode="2" />…

</PipingNetworkSegment>

• ConnectionPointsThis element is used to describe the potential flow connections from and to the parent of this element. Each potential connection location is represented as a Node element. Nodes are ordered and positioned on the drawing. Each Node element may be referenced by at most one Connection element.

The first node (known as Node 0) represents the geometric origin of the parent of the ConnectionPoints element.

Attribute Name Required Description

ToID N The ID, PersistentID/@Identifier or TagName of the referenced item that is the flow destination for the parent of the Connection element. See TagName Referencing.

ToNode N The index of the ConnectionPoints Node element within the ConnectionPoints element of the destination element. Nb this is a 0 based index and is only required if the destination is not a Nozzle, PipeConnectorSymbol or PropertyBreak.

FromID N The ID, PersistentID/@Identifier or TagName of the referenced item that is the flow source for the parent of the Connection element. See TagName Referencing.

FromNode N The index of the ConnectionPoints Node element within the ConnectionPoints element of the source element. Nb this is a 0 based index and is only required if the source is not a Nozzle, PipeConnectorSymbol or PropertyBreak.

12.19:114© 2011 AVEVA Solutions Ltd

Page 739: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

Example:

<ConnectionPoints NumPoints="4" FlowIn="1" FlowOut="2"><!-- Node 0 : Geometric origin of the component --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Node><!-- Node 1 : FlowIn default --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position>

Element Name Cardinality Description

Presentation 0..1 The Presentation element has no purpose in this context.

Extent 0..1 The minimum bounding geometry of the geometric contents of the ConnectionPoints element and its descendants.

Node 1..* The first node (Node 0) represents the geometric location of the parent element. Nodes 1..n represent the locations that other elements may connect to.

GenericAttributes 0..* Any Application attributes related to connectivity

Attribute Name Required Description

NumPoints Y The number of Node elements in this ConnectionPoints element.

FlowIn N The index of the Node that is used for the primary flow into the parent of the ConnectionPoints element. This Defaults to 1 if not present.

FlowOut N The index of the Node that is used for the primary flow from the parent of the ConnectionPoints element. This defaults to 2 if not present.

12.19:115© 2011 AVEVA Solutions Ltd

Page 740: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<NominalDiameter Value="4" /></Node><!-- Node 2 : FlowOut default --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><NominalDiameter Value="4" />

</Node><!-- Node 3 : Secondary flow, direction not stated --><Node>

<Position><Location X="337" Y="211" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><NominalDiameter Value="4" />

</Node></ConnectionPoints>

• ConnectionTypeThis is a free form string element that may be unit qualified.

Child elements:

None

Attributes:

Example:<ConnectionType>Welded</ConnectionType>

• ControlPointsChild elements :

Attributes:

None

Example:

<ControlPoints>

Attribute Name Required Description

Units N This may contain any of the permitted units types See Units.

Element Name Cardinality Description

Coordinate 1..*

12.19:116© 2011 AVEVA Solutions Ltd

Page 741: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/><Coordinate X="10241.64" Y="10283.399" Z="41.0"/>

</ControlPoints>

• ControlPointWeightThis is defined as an any but should be considered to be of type xsd:integer.

Child elements:

None

Attributes :

None

Example:

<ControlPointWeight>1</ControlPointWeight>

• CoordinateA Coordinate element is a Tuple of ordinates denoting a location in the drawing plane. For 2D drawings the Z ordinates should always be 0.

Child elements:

None

Attributes:

Example:

<Coordinate X="112" Y="106" Z="0" /><Coordinate X="112" Y="110" />

• CrossPageConnectionAn element describing how to match PipeConnectorSymbol and SignalConnectorSymbol to represent cross page connectivity on a P&ID.

Child elements:

Attribute Name Required Description

X Y The X Axis ordinate as a double

Y Y The Y Axis ordinate as a double

Z N The Z Axis ordinate as a double, If not present this defaults to 0.0

Element Name Cardinality Description

LinkedPersistentID 0..* The identities of the element that the parent connector symbol connected to

12.19:117© 2011 AVEVA Solutions Ltd

Page 742: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<CrossPageConnection DrawingName="A1-51-2003-1" LinkLabel="RV00011"/>

<CrossPageConnection><LinkedPersistentID Identifier="ID" Context="AContext"/>

</CrossPageConnection>

• DescriptionA textual description of an item

Child elements:

None

Attributes:

None

Example:<Description>some piece of plant equipment</Description>

• DisciplineThis is a simple element with no attributes containing one of the following values to classify an element:

Electrical

Mechanical

Process

HVAC

Telecomms

Example:

<Discipline>Mechanical</Discipline>

Attribute Name Required Description

DrawingName N The Name attribute of the Drawing that the matching ConnectorSymbol is on. Depending on whether the attribute for matching is unique to a drawing or the entire project this may be required.

LinkLabel N The unique key used to match this connector with its matching counterpart. If DrawingName is provided this should be unique to the referenced drawing, otherwise this must be unique to the project.

12.19:118© 2011 AVEVA Solutions Ltd

Page 743: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• DrawingThis contains metadata about the drawing and graphical annotation for the drawing that the file contains.

Child elements:

Attributes:

Element Name Cardinality Description

Presentation 1 The R, G and B values of this element define the background colour for the drawing. This is in contrast to the normal use of the Presentation element that defines foreground style information.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

Component 0..* A PlantItem used to group annotation.

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A geometric primitive

Ellipse 0..* A geometric primitive

Line 0..* A geometric primitive

Polyline 0..* A geometric primitive

Shape 0..* A geometric primitive

TrimmedCurve 0..* A geometric primitive

Text 0..* Textual annotation on the drawing

DrawingBorder 0..* This element may be used to store the drawing border/outline but this is at the discretion of the export tool.

Label 0..*

InsulationSymbol 0..*

ScopeBubble 0..*

GenericAttributes 0..* Any application specific properties relating to the Drawing.

Attribute Name Required Description

Name Y Identity for the drawing, this must be unique in the project.

Type Y Fixed value of ‘PID’

12.19:119© 2011 AVEVA Solutions Ltd

Page 744: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<Drawing Name="A1-51-2003-1" Type="PID" Size="A0"Title="Sample Project drawing" Revision="A"><Presentation R="0" G="0" B="0" /><Extent>

<Min X="0" Y="-2" Z="0" /><Max X="850.0" Y="620.25" Z="0" />

</Extent><PolyLine NumPoints="4">…</PolyLine>…

</Drawing>

• DrawingBorderThis element may be used to separate the drawing frame and borders from the drawing annotation.

Child elements:

Revision N Free form string value. See Character encoding

Title Y The drawing title

Size N This is a free text string and has no defined syntax. See Character encoding.

Attribute Name Required Description

Element Name Cardinality Description

Presentation 0..1 The Presentation element has no purpose in this context.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

BsplineCurve 0..* A geometric primitive

Circle 0..* A geometric primitive

CompositeCurve 0..* A geometric primitive

Ellipse 0..* A geometric primitive

Line 0..* A geometric primitive

Polyline 0..* A geometric primitive

Shape 0..* A geometric primitive

TrimmedCurve 0..* A geometric primitive

Text 0..*

GenericAttributes 0..* Any application specific properties relating to the Drawing.

12.19:120© 2011 AVEVA Solutions Ltd

Page 745: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<DrawingBorder Name="Top" Size="A0-Portrait"><Presentation R="0" G="0" B="0" /><Extent>

<Min X="0" Y="-2" Z="0" /><Max X="850.0" Y="620.25" Z="0" />

</Extent><PolyLine NumPoints="4">…</PolyLine>…

</DrawingBorder>

• EllipseA geometric primitive used to describe an ellipse.

Child elements:

Attributes:

Example:

<Ellipse PrimaryAxis="7.62" SecondaryAxis="3.83916"><Presentation Layer="Default" LineType="Solid" LineWeight="0.13 mm" Color="Red" R="1" G="0" B="0"/><Extent>

Attribute Name Required Description

Name N Identity for the drawing border

Size N This is a free text string and has no defined syntax. See Character encoding.

Element Name Cardinality Description

Presentation 1 This defines the drawing style to be used for the ellipse.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

Position 1 The centre/origin of the ellipse to draw

GenericAttributes 0..* A geometric primitive

Attribute Name Required Description

PrimaryAxis Y Double describing the primary axis

SecondaryAxis Y double describing the secondary axis

Filled N A value of ‘Solid’ or ‘Hatch’. If not present the ellipse is not filled.

12.19:121© 2011 AVEVA Solutions Ltd

Page 746: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Min X="184.52505999" Y="425.32167093" Z="0"/><Max X="199.76504821" Y="429.16757932" Z="0"/>

</Extent><Position>

<Location X="192.145059987" Y="425.328421759" Z="0"/>

<Axis X="0" Y="0" Z="1"/><Reference X="1" Y="0" Z="0"/>

</Position></Ellipse>

• EndDiameterThis is the internal bore for a segment or a PipingNetworkSystem at its destination.

Child elements:

None

Attributes:

Example:

<EndDiameter Value="4" />

<EndDiameter Value="200" Units="mm" />

• EquipmentAn Equipment element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attribute Name Required Description

Value Y The bore size

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

Discipline 0..1 Functional domain of Equipment

NormalOperatingPressure 0..1

MinimumDesignPressure 0..1

MaximumDesignPressure 0..1

MinimumDesignTemperature

0..1

MaximumDesignTemperature

0..1

12.19:122© 2011 AVEVA Solutions Ltd

Page 747: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<Equipment ID="ID_12" Tag="P-1502B" ComponentClass="VerticalPump"

ComponentName="VPump" StockNumber="puv1"><Extent>

<Min X="199.6153088" Y="155.02299606" Z="0" /><Max X="236.78321894" Y="194.01149803" Z="0" />

</Extent><Position>

<Location X="221" Y="182" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><PersistentID Identifier="{A1-51-2003-1_Topology-EQUIPMENT-2}" Context="http://www.aveva.com/example/P&amp;ID" />…<Nozzle ID="ID_14" Tag="N2" ComponentClass="FlangedNozzle"

StockNumber="flnn1">…

</Nozzle></Equipment>

• ExtentA minimum bounding geometry describing the minimum and maximum coordinates of the descendants of this elements parent.

Equipment 0..* Equipment considered part of this equipment

Nozzle 0..* Potential pipe connection to this equipment

Component 0..*

Attribute Name Required Description

ProcessArea N A free form string identifying, if required, the process area that this equipment resides in (See Character encoding).

Purpose N A free form string describing the function of this equipment in the process (see Character encoding).

Element Name Cardinality Description

12.19:123© 2011 AVEVA Solutions Ltd

Page 748: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

None

Example:

<Extent><Min X="199.6153088" Y="155.02299606" Z="0" /><Max X="236.78321894" Y="194.01149803" Z="0" />

</Extent>

• FabricationCategoryThis is a free form string element that may be unit qualified.

Child elements:

None

Attributes:

Example:

None

• GenericAttributeAn application specific attribute/property in the XMpLant file.

Child elements :

None

Attributes:

Element Name Cardinality Description

Min 1 Minimum values for all geometric descendants of the Extent elements parent.

Max 1 Maximum values for all geometric descendants of the Extent elements parent

Attribute Name Required Description

Units N This may contain any of the permitted units types See Units.

Attribute Name Required Description

Name Y The name of the attribute.

Value N If Value is not present this is equivalent to null. This may not be equivalent to "".

12.19:124© 2011 AVEVA Solutions Ltd

Page 749: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<GenericAttributes Number="1" Set="Instrument"><GenericAttribute Name="TagSuffix"

Format="string" Value="AB"/></GenericAttributes>

• GenericAttributesThis element groups application specific attributes/properties to be output into an XMpLant file.

Child elements:

Attributes:

Example:

<GenericAttributes Number="1" Set="Instrument">

Units N The units of measure for the field if relevant. If not present this defaults to the values in PlantInformation. See PlantInformation and Units.

Format N One of the following values (as per 32 bit architecture):

string byte short integer long ulong float double

URI N A URI to the RDL WIP qualifying the attribute being represented.

Attribute Name Required Description

Element Name Cardinality Description

GenericAttribute @Number The contents of a GenericAttributes element are not validated and may be any valid XML content. However the XML applications will expect the contents to conform to the schema fragment provided above.

Attribute Name Required Description

Number Y The number of GenericAttributes inside this set.

Set N A name for this grouping of attributes.

12.19:125© 2011 AVEVA Solutions Ltd

Page 750: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<GenericAttribute Name="TagSuffix" Format="string" Value="AB"/>

</GenericAttributes>

• HeightThis is the height of the Nozzle origin on it’s parent Equipment, measured from the origin of the Equipment.

Child elements:

None

Attributes:

Example:<Height Value="1.3" Units="m"/>

• HistoryThis is provided to contain an audit trail of the changes to an item.

Child elements:

Attributes:

Example:

<History NumTransaction="3"><Transaction ... /><Transaction ... /><Transaction ... />

</History>

• IdentifierThis element is used to capture the structure of an identifier such as a TagName. Not usually used.

Attribute Name Required Description

Value Y The height value

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

Transaction 0..* An entry in the audit trail

Attribute Name Required Description

NumTransactions Y The number of Transaction child elements

12.19:126© 2011 AVEVA Solutions Ltd

Page 751: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

Example:

<Identifier Purpose="Tag breakdown"><IdentifierElement Name="start" Value="AB-"/><IdentifierElement Name="middle" ItemID="ID_24"

DependantAttribute="[Prefix]-[Number]"/></Identifier>

• IdentifierElementA structural element describing part of the structure of an identifier.

Child elements:

None

Attributes:

Example:

<IdentifierElement Name="start" Value="AB-"/>

<IdentifierElement Name="middle" ItemID="ID_24" DependantAttribute="[Prefix]-[Number]"/>

• InsideDiameterThis is the internal bore for an item at its source end.

Child elements:

Element Name Cardinality Description

IdentifierElement 0..* A structural component of an identifier.

Attribute Name Required Description

Purpose N A string describing the purpose of this element.

Attribute Name Required Description

Name Y The name of this part of the identifier

Value N Only required if dependantAttribute is not provided.

ItemID N Only required if an attribute is referenced on another item.

DependantAttribute N References an attribute from which this part of the identifier is derived. See Textfor a description of how this attribute is defined.

12.19:127© 2011 AVEVA Solutions Ltd

Page 752: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

None

Attributes:

Example:

<InsideDiameter Value="4" />

<InsideDiameter Value="200" Units="mm" />

• InstrumentComponentThis represents a physical instrument that is common to piping systems that is not part of the process line.

An InstrumentComponent element inherits elements and attributes from the base type 'PlantItem'. See 'PlantItem' for the definitions of the inherited contents.

Child elements:

Attributes:

(See 'PlantItem') No Additional elements

Examples:

<InstrumentComponent ID="ID_33" TagName="LT-117" ComponentClass="LevelTransmitter"><Extent>

<Min X="710" Y="258" Z="0" /><Max X="726" Y="274" Z="0" />

</Extent><Position>

<Location X="718" Y="266" Z="0" /><Axis X="0" Y="0" Z="1" />

Attribute Name Required Description

Value Y The bore size

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

InstrumentComponent 0..* Contained Instrument.

NominalDiameter 0..1

InsideDiameter 0..1

None OutsideDiameter

0..1

OperatorType 0..1

WallThickness 0..1

Component 0..*

12.19:128© 2011 AVEVA Solutions Ltd

Page 753: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Reference X="1" Y="0" Z="0" /></Position><Circle Radius="8" … /><Text … />

</InstrumentComponent>

• InstrumentConnectionThis represents a connection for purposes of instrumentation to a process line. Even though this is a topological break this doesn't terminate the PipingNetworkSegment (see PipingNetworkSegment Topology (Connection element))

An InstrumentConnection element inherits elements and attributes from the base type 'PlantItem'. See 'PlantItem' for the definitions of the inherited contents.

Child elements:

See 'PlantItem'.

Attributes:

(See 'PlantItem') No Additional elements

Examples:

<InstrumentConnection ID="ID_33" ><Extent>

<Min X="710" Y="258" Z="0" /><Max X="726" Y="274" Z="0" />

</Extent><Position>

<Location X="718" Y="266" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position>…

</InstrumentConnection>

• InstrumentLoopA collection of related instruments. This element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents. Inline instruments are associated to instrument loops by using the Association element.

Child elements:

Attributes:

See ‘PlantItem’, no additional attributes are defined.

Example:

Element Name Cardinality Description

ProcessInstrument 0..* An off-line instrument that is part of this set.

SignalLine 0..*

SignalConnectorSymbol 0..*

12.19:129© 2011 AVEVA Solutions Ltd

Page 754: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<InstrumentLoop ID="ID_123"><Extent>

<Min X="355" Y="339" Z="0" /><Max X="481" Y="355" Z="0" />

</Extent><SignalLine ... /><SignalLine ... /><SignalLine ... /><ProcessInstrument ... /><ProcessInstrument ... />

</InstrumentLoop>

• InsulationSymbolThis element is an annotation primitive to represent a label on a P&ID.

An InsulationSymbol element inherits elements and attributes from the base type 'AnnotationItem'. See 'AnnotationItem' for the definitions of the inherited contents.

Child elements :

See 'AnnotationItem') No Additional elements

Attributes :

See 'AnnotationItem') No Additional attributes

Example :

<InsulationSymbol ID="ID_29" ComponentName="Insulation" ><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="671" Y="148" Z="0" /><Max X="673" Y="152" Z="0" />

</Extent><Position>

<Location X="672" Y="148" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="0" Y="1" Z="0" />

</Position>…

</InsulationSymbol>

• KnotMultiplicitiesChild elements:

Attributes:

None

Element Name Cardinality Description

Multiplicity 1..*

12.19:130© 2011 AVEVA Solutions Ltd

Page 755: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<KnotMultiplicities><Multiplicity>4</Multiplicity><Multiplicity>4</Multiplicity>

</KnotMultiplicities>

• KnotThis is defined as an any but should be considered to be of type xsd:integer.

Child elements :

None

Attributes:

None

Example:<Knot>1</Knot>

• Knots

Child elements:

• LabelThis element is an annotation primitive to represent a label on a P&ID.

A Label element inherits elements and attributes from the base type 'AnnotationItem'. See 'AnnotationItem' for the definitions of the inherited contents.

Child elements:

(See 'AnnotationItem') No Additional elements

Attributes:

(See 'AnnotationItem') No Additional attributes

Example:

<Label ID="ID_29" ComponentName="LineLabel" ><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="671" Y="148" Z="0" /><Max X="673" Y="152" Z="0" />

</Extent><Position>

<Location X="672" Y="148" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="0" Y="1" Z="0" />

</Position>

Element Name Cardinality Description

Knot 1..*

12.19:131© 2011 AVEVA Solutions Ltd

Page 756: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

…</Label>

• LineA linear geometry defined by two points.

Child elements:

Attributes:

None

Example:

<Line><Presentation LineWeight="1" LineType="Solid"

Color="red" R="1" G="0" B="0" />

<Extent><Min X="831" Y="502.6" Z="0" /><Max X="841" Y="502.6" Z="0" />

</Extent><Coordinate X="841" Y="502.6" Z="0" /><Coordinate X="831" Y="502.6" Z="0" />

</Line>

• LinkedPersistentIDThe LinkedPersistentID element contains a source system identifier for an for a PipeConnectorSymbol or SignalConnectorSymbol that the containing connector element is linked to. The Identifier and the Context must match the PersistentIdentifier attributes on the reference element. See PersistentID.

Child elements:

None

Attributes:

Element Name Cardinality Description

Presentation 1 This defines the drawing style to be used for the ellipse.

Extent 1 The minimum bounding geometry of the geometric contents of the Drawing element and its descendants.

Coordinate 2 The coordinates defining the start and end of the line.

GenericAttributes 0..* A geometric primitive

12.19:132© 2011 AVEVA Solutions Ltd

Page 757: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<LinkedPersistentID Identifier="{A1-51-2003-1_Topology-NOZZLE-1}"

Context="http://www.aveva.com/example/P&amp;ID" />

• LocationA Location element matches the definition of a Coordinated, it is a Tuple of ordinates denoting a location in the drawing plane. For 2D drawings the Z ordinates should always be 0.

Child elements:

None

Attributes:

Example:<Location X="112" Y="106" Z="0" /><Location X="112" Y="110" />

• ManufacturerThe manufacturer responsible for producing the item

Child elements:

None

Attributes:

None

Example:<Manufacturer>My company</Manufacturer>

• MaterialThe name of the Material used to construct the item

Child elements:

Attribute Name Required Description

Identifier Y The persistent identifier for an XMpLant element

Context N The scopes of the persistent identifier

Attribute Name Required Description

X Y The X Axis ordinate as a double

Y Y The Y Axis ordinate as a double

Z N The Z Axis ordinate as a double, If not present this defaults to 0.0

12.19:133© 2011 AVEVA Solutions Ltd

Page 758: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

None

Attributes:

None

Example:<Material>Copper</Material>

• MaterialDescriptionA description of the material relating to an item

Child elements:

None

Attributes:

None

Example:<MaterialDescription>Some descriptive text</

MaterialDescription>

• MaxMaximum coordinates for an Extent element

Child elements:

None

Attributes:

Example:<Max X="236.78321894" Y="194.01149803" Z="0" />

• MaximumDesignPressureThe maximum design pressure for an item.

Child elements:

None

Attribute Name Required Description

X Y X axis value denoting the maximum X value for all geometric descendants of ../..

Y Y Y axis value denoting the maximum Y value for all geometric descendants of ../..

Z Y Z axis value denoting the maximum Z value for all geometric descendants of ../.. For 2D drawings this should always be 0

12.19:134© 2011 AVEVA Solutions Ltd

Page 759: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<MaximumDesignPressure Value="12" />

<MaximumDesignPressure Value="35" Units="bar" />

• MaximumDesignTemperatureThe maximum design temperature for an item.

Child elements:

None

Attributes:

Example:

<MaximumDesignTemperature Value="12" />

<MaximumDesignTemperature Value="35" Units="DegreeCelsius" />

• MaximumOperatingPressureThe maximum operating pressure for an item.

Child elements:

None

Attributes:

Example:

Attribute Name Required Description

Value Y The maximum design pressure

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The maximum design temperature

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The maximum pressure

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

12.19:135© 2011 AVEVA Solutions Ltd

Page 760: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<MaximumOperatingPressure Value="12" /><MaximumOperatingPressure Value="35" Units="bar" />

• MaximumOperatingTemperatureThe maximum operating temperature for an item.

Child elements:

None

Attributes:

Example:

<MaximumOperatingTemperature Value="12" /><MaximumOperatingTemperature Value="35" Units="DegreeCelsius"

/>

• MinChild elements:

None

Attributes:

Example:<Min X="199.6153088" Y="155.02299606" Z="0" />

• MinimumDesignPressureThis is the minimum design pressure for an item.

Child elements:

Attribute Name Required Description

Value Y The maximum temperature

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

X Y X axis value denoting the minimum X value for all geometric descendants of ../… This is a double

Y Y Y axis value denoting the minimum Y value for all geometric descendants of ../.. This is a double

Z Y Z axis value denoting the minimum Z value for all geometric descendants of ../.. This is a double. For 2D drawings this should always be 0.

12.19:136© 2011 AVEVA Solutions Ltd

Page 761: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

None

Attributes:

Example:

<MinimumDesignPressure Value="12" /><MinimumDesignPressure Value="35" Units="bar" />

• MinimumDesignTemperatureThis is the minimum design temperature for an item.

Child elements:

None

Attributes:

Example:

<MinimumDesignTemperature Value="12" /><MinimumDesignTemperature Value="35" Units="DegreeCelsius" />

• MinimumOperatingPressureThis is the minimum operating pressure for an item.

Child elements:

None

Attributes:

Example:

Attribute Name Required Description

Value Y The minimum design pressure as a double.

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The minimum design temperature as a double.

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The minimum pressure as a double.

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

12.19:137© 2011 AVEVA Solutions Ltd

Page 762: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<MinimumOperatingPressure Value="12" /><MinimumOperatingPressure Value="35" Units="bar" />

• MinimumOperatingTemperatureThis is the minimum operating temperature for an item.

Child elements:

None

Attributes:

Example:

<MinimumOperatingTemperature Value="12" />

<MinimumOperatingTemperature Value="35" Units="DegreeCelsius"/>

• ModelNumberString element detailing the model number for a component.

Child elements:

None

Attributes:

None

Example:<ModelNumber>A485798347-BjiOM-9347</ModelNumber>

• MultiplicityThis is defined as an any but should be considered to be of type xsd:integer.

Child elements:

None

Attributes:

None

Example:<Multiplicity>4</Multiplicity>

• NominalDiameterThis is the internal bore for an item.

Attribute Name Required Description

Value Y The minimum temperature as a double.

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

12.19:138© 2011 AVEVA Solutions Ltd

Page 763: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

None

Attributes:

Example:

<NominalDiameter Value="4" /><NominalDiameter Value="200" Units="mm" />

• NormalDesignPressureDesign pressure of an item under normal conditions.

Child elements:

None

Attributes:

Example:

<NormalDesignPressure Value="4" /><NormalDesignPressure Value="3" Units="barg" />

• NormalDesignTemperatureDesign temperature of an item under normal conditions.

Child elements:

None

Attributes:

Example:

Attribute Name Required Description

Value Y The bore size as a double

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The pressure value as a double

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The temperature value as a double

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

12.19:139© 2011 AVEVA Solutions Ltd

Page 764: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<NormalDesignTemperature Value="52" /><NormalDesignTemperature Value="80" Units="DegreeCelsius" />

• NormalOperatingPressureOperating pressure of an item under normal conditions.

Child elements:

None

Attributes:

Example:

<NormalOperatingPressure Value="4" /><NormalOperatingPressure Value="3" Units="barg" />

• NormalOperatingTemperatureOperating temperature of an item under normal conditions

Child elements:

None

Attributes:

Example:

<NormalOperatingTemperature Value="52" /><NormalOperatingTemperature Value="80" Units="DegreeCelsius"

/>

• NozzleA Nozzle element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Attribute Name Required Description

Value Y The pressure value as a double

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The temperature value as a double

Units N This may be any of the temperature units permitted. See Units for permitted values and semantics if not present.

12.19:140© 2011 AVEVA Solutions Ltd

Page 765: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<Nozzle ID="ID_10" Tag="N1" ComponentClass="FlangedNozzle"><Extent>

<Min X="205.47371879" Y="245.5" Z="0" /><Max X="215" Y="263" Z="0" />

</Extent><Position>

<Location X="215" Y="255" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="-1" Y="0" Z="0" />

</Position><PersistentID Identifier="{A1-51-2003-1_Topology-

NOZZLE-1}" Context="http://www.aveva.com/example/P&amp;ID" /

><Line>

<Presentation LineType="Solid" LineWeight="1" R="0.25" G="0.82" B="0.15" />

<Extent><Min X="211" Y="255" Z="0" /><Max X="215" Y="255" Z="0" />

</Extent><Coordinate X="211" Y="255" Z="0" /><Coordinate X="215" Y="255" Z="0" />

</Line>…<NominalDiameter Value="4" />

</Nozzle>

• NozzleTypeThis is a simple element with one attribute and no contents

Child elements:

None

Element Name Cardinality Description

NozzleType 0..1

NominalDiameter 0..1 Internal nominal bore of nozzle

Height 0..1 Height of Nozzle on the Equipment

12.19:141© 2011 AVEVA Solutions Ltd

Page 766: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:<NozzleType Value="Flanged"/>

• OperatorTypeThis is a free form string element that may be unit qualified.

Child elements:

None

Attributes:

Example:

None

• OutsideDiameterThis is the external diameter of an item.

Child elements:

None

Attributes:

Example:

<OutsideDiameter Value="4" /><OutsideDiameter Value="200" Units="mm" />

• PConnectionPointsTo be defined.

Attribute Name Required Description

Value N One of ‘Welded’, ‘Flanged’ or ‘Elbow’. This defaults to ‘Flanged’ if the Value attribute isn’t present.

Attribute Name Required Description

Units N This may contain any of the permitted units types See Units.

Attribute Name Required Description

Value Y The external diameter measurement as a double

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

12.19:142© 2011 AVEVA Solutions Ltd

Page 767: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• PersistentIDThe PersistentID element contains a source system identifier for an object that remains consistent between exports of a drawing. A PersistentID is made up of two components the identifier and its scope.

A PersistentID should be the same for an object that appears on multiple drawings where it is practicable to do this. If this cannot be achieved the TagName, if present, will be used by P&ID Manager for rationalising objects.

Child elements:

None

Attributes:

Example:

<PersistentID Identifier="{A1-51-2003-1_Topology-NOZZLE-1}"

Context="http://www.aveva.com/example/P&amp;ID" />

• PipeConnectorSymbolAn on or off page connector that represents the connectivity of a PipingNetworkSegment across a page boundary. These are contained by the PipingNetworkSegment elements and reference as the segment source or destination.

A PipeConnectorSymbol element inherits elements and attributes from the base type ‘PlantItem’. See ‘AnnotationItem’ for the definitions of the inherited contents.

Child elements:

Attribute Name Required Description

Identifier Y The persistent identifier for an XML element. The Identifier must be unique within the set of XML files that may interact directly or indirectly with this drawing for the stated context. This a free form string type, see Character encoding.

Context N This scopes a persistent identifier. In this way an item may have different Identifiers for different systems/contexts and each identifier may be represented. Ideally this would be encoded as a URI. For example http://www.aveva.com/P&ID Designer/ProjectName.

Element Name Cardinality Description

CrossPageConnection 0..1 Information describing the matching criteria for the PipeConnectorSymbol that is connected to this one.

12.19:143© 2011 AVEVA Solutions Ltd

Page 768: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

See ‘AnnotationItem’, no Additional attributes

Example:

<PipeConnectorSymbol ID="ID_92" Tag="A1-51-2003-3" StockNumber="flag1">

<Presentation LineType="Solid" LineWeight="1" Color="7" R="1" G="1" B="1" />

<Extent … /><Position … /><PersistentID … /><PolyLine … /><Text … /><CrossPageConnection … />

</PipeConnectorSymbol>

• PipeFlowArrowThis element is an annotation primitive to represent the direction of flow of a PipingNetworkSegment.

A PipeFlowArrow element inherits elements and attributes from the base type ‘AnnotationItem’. See ‘AnnotationItem’ for the definitions of the inherited contents.

Child elements:

See ‘AnnotationItem’, no additional elements

Attributes:

See ‘AnnotationItem, no additional attributes

Example:

<PipeFlowArrow ID="ID_29" ><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="671" Y="148" Z="0" /><Max X="673" Y="152" Z="0" />

</Extent><Position>

<Location X="672" Y="148" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="0" Y="1" Z="0" />

</Position><PolyLine NumPoints="42">

<Presentation LineType="Solid" LineWeight="1" Color="7" R="1" G="1" B="1" />

<Extent><Min X="671" Y="148" Z="0" /><Max X="673" Y="152" Z="0" />

</Extent><Coordinate X="671" Y="152" Z="0" />

12.19:144© 2011 AVEVA Solutions Ltd

Page 769: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Coordinate X="672" Y="148" Z="0" /><Coordinate X="673" Y="152" Z="0" /><Coordinate X="671" Y="152" Z="0" />

</PolyLine></PipeFlowArrow>

• PipingComponentThis represents a physical component that is common to piping systems.

A PipingComponent element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

Example:

<PipingComponent ID="ID_5568" ComponentClass="PipeTee"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

Element Name Cardinality Description

PipingComponent 0..* Contained PipingComponent.

ConnectionType 0..1

NominalDiameter 0..1

InsideDiameter 0..1

None Outside Diameter

0..1

OperatorType 0..1

WallThickness 0..1

FabricationCategory 0..1

PipingComponent 0..*

Component 0..*

Attribute Name Required Description

ConnectionType N This is a free text string and has no defined syntax. See Character encoding

Rating N This is a free text string and has no defined syntax. See Character encoding

Standard N This is a free text string and has no defined syntax. See Character encoding

ISOSymbol N This is a free text string and has no defined syntax. See Character encoding

12.19:145© 2011 AVEVA Solutions Ltd

Page 770: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Min X="112" Y="182" Z="0" /><Max X="112" Y="182" Z="0" />

</Extent><Position>

<Location X="112" Y="182" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><PersistentID … /><ConnectionPoints NumPoints="4" FlowIn="1" FlowOut="2"

… /></PipingComponent>

• PipingNetworkSegmentSee PipingNetworkSegment Topology (Connection element) for details on the use of PipingNetworkSegments.

A PipingNetworkSegment element inherits elements and attributes from the base type 'PlantItem'. See 'PlantItem' for the definitions of the inherited contents.

PipeConnectorSymbol elements representing on and off page connectivity are contained by the PipingNetworkSegment. See for details of PipingNetworkSegment connectivity.

If a PipingNetworkSegment represents the connectivity between an instrument and a process line then the ComponentClass attribute will be given the value 'ProcessInstrumentConnection'

Child Elements:

Element Name Cardinality Description

NominalDiameter 0..1

InsideDiameter 0..1

None Outside Diameter

0..1

StartDiameter 0..1

EndDiameter 0..1

NormalDesignPressure 0..1

MinimumDesignPressure 0..1

MaximumDesignPressure 0..1

NormalDesignTemperature 0..1

MinimumDesignTemperature

0..1

MaximumDesignTemperature

0..1

NormalOperatingPressure 0..1

12.19:146© 2011 AVEVA Solutions Ltd

Page 771: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

<PipingNetworkSegment ID="ID_86" Tag="B-902" Specification="A3B">

<Extent>

MinimumOperatingPressure

0..1

MaximumOperatingPressure

0..1

TestPressure 0..1

NormalOperatingTemperature

0..1

MinimumOperating Temperature

0..1

MaximumOperatingTemperature

0..1

WallThickness 0..1

Connection 0..* This states the head and tail connectivity of this segment.

SpecificationBreak 0..* Points at which changes occur in the pipe specification. This causes a break in the segment.

CenterLine 0..*

Component 0..*

InstrumentComponent 0..*

Equipment 0..*

InstrumentConnection 0..*

PipingComponent 0..*

ProcessInstrument 0..*

PipeConnectorSymbol 0..*

PipeFlowArrow 0..*

Label 0..*

InsulationSymbol 0..*

Attribute Name Required Description

DualFlow N Defaults to 'false', indicates that the segment supports reversible flow.

Element Name Cardinality Description

12.19:147© 2011 AVEVA Solutions Ltd

Page 772: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Min X="227" Y="118" Z="0" /><Max X="337" Y="211" Z="0" />

</Extent><PersistentID Identifier="{A1-51-2003-1_Topology-

SEGMENT-1}"Context="http://www.aveva.com/example/P&amp;ID" /

><Connection FromID="ID_73" ToID="ID_87" ToNode="2" /><NominalDiameter Value="4" /><PipeFlowArrow ID="ID_78" … /><CenterLine NumPoints="3">

<Presentation LineType="Solid" LineWeight="1" Color="7" R="1" G="1" B="1" />

<Extent><Min X="227" Y="118" Z="0" /><Max X="227" Y="132" Z="0" />

</Extent><Coordinate X="227" Y="118" Z="0" /><Coordinate X="227" Y="132" Z="0" /><Coordinate X="291" Y="132" Z="0" />

</CenterLine><PipingComponent ID="ID_87" ComponentClass="PipeTee" …

/></PipingNetworkSegment>

• PipingNetworkSystem'A PipingNetworkSystem contains the information for a physical PipingNetworkSystem in the plant or a section thereof as contained within a module. The PipingNetworkSystem contains all of the PlantItems that belong to it. A PipingNetworkSystem may have multiple sources and multiple destinations.'

A PipingNetworkSystem element inherits elements and attributes from the base type 'PlantItem'. See 'PlantItem' for the definitions of the inherited contents.

Child elements:

Element Name Cardinality Description

NominalDiameter 0..1

InsideDiameter 0..1

OutsideDiameter 0..1

StartDiameter 0..1

EndDiameter 0..1

NormalDesignPressure 0..1

MinimumDesignPressure 0..1

MaximumDesignPressure 0..1

12.19:148© 2011 AVEVA Solutions Ltd

Page 773: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes :

(See 'PlantItem') No Additional attributes

Example :

<PipingNetworkSystem ID="ID_1256"><Extent ... /><PersistentID ... /><NominalDiameter ... /><MinimumDesignPressure ... /><MaximumDesignPressure ... /><PipingNetworkSegment ... /><PipingNetworkSegment ... /><PipingNetworkSegment ... /><PropertyBreak ... />

</PipingNetworkSystem>

• PipingSystemTo be defined.

• PlantAreaIn the P&ID content of an XML file this is just an object that may be used to represent the name and attributes of named part(area) of a plant. A plant Area is not permitted to contain model elements but may be referenced to associated segments, Equipment etc with a named PlantArea.

NormalDesignTemperature 0..1

MinimumDesignTemperature 0..1

MaximumDesignTemperature 0..1

NormalOperatingPressure 0..1

MinimumOperatingPressure 0..1

MaximumOperatingPressure 0..1

TestPressure 0..1

NormalOperatingTemperature 0..1

MinimumOperatingTemperature 0..1

MaximumOperatingTemperature 0..1

WallThickness 0..1

PipingNetworkSegment 0..* The segments that make up the PipingNetworkSystem

PropertyBreak 0..* Points at which changes occur in the pipe specification. This causes a break in the segment.

Element Name Cardinality Description

12.19:149© 2011 AVEVA Solutions Ltd

Page 774: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

A PlantArea element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

Example:

<PlantArea Name="Area-42"><Extent .. /><Association ../><Association ../><Association ../>

</PlantArea>

• PlantInformationThis element collects the metadata for a PlantModel. The Date and Time attributes should be the Date and Time of the XML file creation.

Child elements:

Attributes:

Element Name Cardinality Description

Component 0..*

Attribute Name Required Description

Name N A string representing the name of the area. See Character encoding.

Element Name Cardinality Description

UnitsOfMeasure 1 Defines the default units of measure for the file.

Attribute Name Required Description

SchemaVersion Y Fixed value of ‘3.3.3’

OriginatingSystem Y Free form string. See Character encoding

ModelName N Free form string. See Character encoding

Date Y XML date of the format YYYY-MM-DD

ProjectName N Free form string. See Character encoding

ProjectCode N Free form string. See Character encoding

ProjectDescription N Free form string. See Character encoding

CompanyName N Free form string. See Character encoding

12.19:150© 2011 AVEVA Solutions Ltd

Page 775: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<PlantInformation SchemaVersion="3.3.3" OriginatingSystem="VPEPID" ModelName="http://www.aveva.com/P&amp;ID/example"Date="2006-12-12" Time="16:43:23" Is3D="no" Units="Millimetre" Discipline="PID"><UnitsOfMeasure Distance="Inch" />

</PlantInformation>

• PlantItemThis element is a base abstract type of many elements within an XML file, it defines the common elements and attributes for these items.

Child elements:

Time Y XML time type, assumed UTC unless zone qualified

Is3D Y Fixed value of ‘no’

Units Y The distance units of measure for the geometry in the file.

Discipline Y Fixed value of ‘PID’

Attribute Name Required Description

Element Name Cardinality Description

Presentation 0..1

Extent 1

PersistentID 0..*

Position 1

Scale 0..1

Surface 0..*

Circle 0..*

CompositeCurve 0..*

Ellipse 0..*

Line 0..*

Polyline 0..*

Shape 0..*

TrimmedCurve 0..*

BsplineCurve 0..*

ConnectionPoints 0..1

PConnectionPoints 0..1

12.19:151© 2011 AVEVA Solutions Ltd

Page 776: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:

N/A since the type is abstract

• PolyLineGeometric curve primitive detailing a polyline. The interpolation between each coordinate is linear.

Text 0..*

Identifier 0..*

Description 0..1

Weight 0..1

Material 0..1

MaterialDescription 0..1

ModelNumber 0..1

Supplier 0..1

Manufacturer 0..1

GenericAttributes 0..*

Association 0..*

History 0..1

Attribute Name Required Description

ID Y The unique identity of the item in the file. See ID.

TagName N See Tag

Specification N See Specification

StockNumber N See StockNumber

ComponentClass N See ComponentClass

ComponentName N See ComponentName

ComponentType N See ComponentType

Revision N See Revision

Status N See Status

Element Name Cardinality Description

12.19:152© 2011 AVEVA Solutions Ltd

Page 777: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Child elements:

Attributes:

Example:

<PolyLine NumPoints="2"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="77" Y="463" Z="0" /><Max X="646" Y="463" Z="0" />

</Extent><Coordinate X="77" Y="463" Z="0" /><Coordinate X="646" Y="463" Z="0" />

</PolyLine>

• PositionThis defines the place where an items origin is on a P&ID drawing. This is in effect the location of the items symbol. The Axis and Reference attributes are used to define the coordinate orientation in 3D space (see Geometries (Axis and Reference)). The drawing is considered to be on the plane of Z=0.

Child elements:

Attributes:

None

Example:

<Position><Location X="716.06" Y="268.76" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position>

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the line. The drawing behaviour is undefined if the Presentation element is missing.

Extent 1 The minimum bounding geometry of the element and its descendants

Coordinate 1..* The coordinates defining the line primitive

Attribute Name Required Description

NumPoints Y The number of child Coordinate elements.

12.19:153© 2011 AVEVA Solutions Ltd

Page 778: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• PresentationThe element defines a styles used to draw geometric and textual content. Whle all attributes are defined as optional in the schema the R, G, B, LineWeight and LineType attributes are expected for all geometric primitives, otherwise the behaviour is undefined.

Child elements:

None

Attributes:

Attribute Name Required Description

Layer N Name of the layer in which the graphical elements resides. This has no functional semantics associated with it.

Color N A lookup in a color index. This is not used by AVEVA software.

LineType N One of the numbers or names from the following (Object Model document v2.2):-

0 Solid 1 Dotted 2 Dashed 3 Long Dash 4 Long Dash + Short Dash, CenterLine 5 Short Dash 6 Long Dash + Short Dash + Short Dash 7 Dash + Short Dash

LineWeight N <real>

or

<real><units>

or

<real><space><units>

Where:-

<real> is an real value. <space> is a space character (&#20;) <units> is a distance units from Units If the value isn’t qualified with units then the behaviour is undefined.

R N 0 to 1 (double) 1 = maximum intensity of Red component.

G N 0 to 1 (double) 1 = maximum intensity of Green component.

B N 0 to 1 (double) 1 = maximum intensity of blue component.

12.19:154© 2011 AVEVA Solutions Ltd

Page 779: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<Presentation LineType="Solid" LineWeight="2mm" Color="22" R="0.8" G="0.25" B="0.1" />

• ProcessInstrumentThis represents a physical instrument that is common to piping systems.

A ProcessInstrument element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

See ‘PlantItem’, no additional attributes

Example:

<ProcessInstrument ID="ID_33" Tag="LT-117" ComponentClass="LevelTransmitter"><Extent>

<Min X="710" Y="258" Z="0" /><Max X="726" Y="274" Z="0" />

</Extent><Position>

<Location X="718" Y="266" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position><Circle Radius="8" … /><Text … />

</ProcessInstrument>

• PropertyBreakThis represents the point at which there is a change in specification of the piping. See Error! Reference source not found.

A PropertyBreak element inherits elements and attributes from the base type 'PlantItem'. See 'AnnotationItem' for the definitions of the inherited contents.

Element Name Cardinality Description

PlantItem 0..* Contained ProcessInstrument.

NominalDiameter 0..1

InsideDiameter 0..1

None Outside Diameter

0..1

OperatorType 0..1

WallThickness 0..1

Component 0..*

12.19:155© 2011 AVEVA Solutions Ltd

Page 780: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

A PropertyBreak may be contained by a PipingNetworkSystem or PipingNetworkSegment element. PropertyBreak elements inside a PipingNetworkSystem are those associated with components such as Tees and Angled Relief Valves. PropertyBreak elements inside a PipingNetworkSegment are involved in the segment topology.

Child elements:

(See 'AnnotationItem') No Additional elements

Attributes:

(See 'AnnotationItem') No Additional attributes

Example:

<PropertyBreak ID="ID_34"><Description>Change in Insulation</Description>

</PropertyBreak>

• RatingThis is a unit qualified string value to describe the rating of an item.

Child elements:

None

Attributes:

Example:<Rating Value="5" Units="bar"/>

• ReferenceSee Geometries (Axis and Reference).

Child elements:

None

Attributes:

Example:

Attribute Name Required Description

Value Y Maximum safe load

Units N This may be any of the units permitted since the type of measurement isn’t specified. See Units for permitted values, the semantics if Units are not present are unclear.

Attribute Name Required Description

X Y Double

Y Y Double

Z Y Double

12.19:156© 2011 AVEVA Solutions Ltd

Page 781: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Reference X="1" Y="0" Z="0" />

• RemarkA string comment element

Child elements:

None

Attributes:

None

Example:<Remark>WP2134</Remark>

• ScaleThe scale element is used when symbols are drawn from a shape catalogue. The Scale element enables symbols to be rescaled when positioned in a drawing.

Child elements:

None

Attributes:

Example:<Scale X="2" Y="2" />

• ScopeBubbleThis element is an annotation primitive to represent a scoped bubble or cloud on a P&ID.

A ScopeBubble element inherits elements and attributes from the base type 'AnnotationItem'. See 'AnnotationItem' for the definitions of the inherited contents.

Child elements:

See 'AnnotationItem') No Additional elements

Attributes:

(See 'AnnotationItem') No Additional attributes

Example:

<ScopeBubble ID="ID_29" ><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="671" Y="148" Z="0" /><Max X="673" Y="152" Z="0" />

Attribute Name Required Description

X Y X scale factor

Y Y Y scale factor

Z N Z scale factor

12.19:157© 2011 AVEVA Solutions Ltd

Page 782: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

</Extent><Position>

<Location X="672" Y="148" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="0" Y="1" Z="0" />

</Position>…

</ScopeBubble>

• ShapeThe Shape element defines a closed curve. The interpolation between each coordinate is linear.

Child elements:

Attributes:

Example:

<Shape NumPoints="4" Filled="Solid" ><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent>

<Min X="77" Y="463" Z="0" /><Max X="646" Y="534" Z="0" />

</Extent><Coordinate X="77" Y="463" Z="0" /><Coordinate X="77" Y="534" Z="0" /><Coordinate X="646" Y="463" Z="0" /><Coordinate X="77" Y="463" Z="0" />

</Shape>

Element Name Cardinality Description

Presentation 0..1 The style to use when drawing the line. The drawing behaviour is undefined if the Presentation element is missing.

Extent 1 The minimum bounding geometry of the element and its descendants

Coordinate 4..* The coordinates defining the primitive. The first coordinate should match the last to complete a closed form.

GenericAttributes 0..* Any application specific attributes

Attribute Name Required Description

NumPoints Y The number of child Coordinate elements.

Filled N One of ‘Solid’ or ‘Hatch’ used to specify a fill technique

12.19:158© 2011 AVEVA Solutions Ltd

Page 783: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• ShapeCatalogueA Shape Catalogue defines a symbol library for a file. See ComponentName for how to reference and name a symbol in the catalogue. See Scale for how to scale symbols when drawn. See Position for how to rotate a symbol.

Child elements:

Attributes:

Example:

<ShapeCatalogue Name="Symbols"><Equipment ID="ID_22" ComponentClass="VerticalPump"

ComponentName="VPump">

Element Name Cardinality Description

Equipment 0..* Equipment symbols

PipingComponent 0..* PipingComponent symbols

Nozzle 0..* Nozzle symbols

ProcessInstrument 0..* ProcessInstrument symbols

ImstrumentComponent 0..*

Component 0..* Component symbols

PipeConnector 0..* PipeConnectorSymbol

SignalConnectorSymbol 0..* SignalConnectorSymbol

InsulationSymbol 0..*

PropertyBreak 0..*

Label 0..*

PipeFlowArrow 0..*

Attribute Name Required Description

Name Y The name of the symbol catalogue, this is a string attribute.

Version N The version of the symbol set.

Units N The distance units that the symbols are defined in. This affects the size of the symbol with respect to the units defined by the PlantInformation/UnitsOfMeasure/@Distance attribute. i.e if Units is different to the PlantInformation default then the symbol is scaled. See the distance section of Units for valid values.

Date N The date the symbol library was created/modified.

12.19:159© 2011 AVEVA Solutions Ltd

Page 784: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Extent … /><Position … /><PersistentID … /><Circle … />…

</Equipment><ShapeCatalogue>

• SignalConnectorSymbol An on or off page connector that represents the connectivity of a SignalLine across a page boundary.

A SignalConnectorSymbol element inherits elements and attributes from the base type ‘AnnotationItem’. See ‘AnnotationItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

See ‘AnnotationItem’, no additional attributes

Example:

<SignalConnectorSymbol ID="ID_92"><Presentation LineType="Solid" LineWeight="1"

Color="7" R="1" G="1" B="1" /><Extent … /><Position … /><PersistentID … /><PolyLine … /><Text … /><CrossPageConnection … />

</SignalConnectorSymbol>

• SignalLineA connection between two instruments carrying instrumentation signals.

A SignalLine element inherits elements and attributes from the base type ‘PlantItem’. See ‘PlantItem’ for the definitions of the inherited contents.

Child elements:

Attributes:

Element Name Cardinality Description

CrossPageConnection 0..1 Information describing the matching criteria for the SignalConnectorSymbol that is connected to this one.

Element Name Cardinality Description

Connection 0..1 The connectivity details of this SignalLine

Component 0..*

12.19:160© 2011 AVEVA Solutions Ltd

Page 785: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

See ‘PlantItem’, no additional attributes

Example:

<SignalLine ID="ID_86" TagName="B-902" ><Extent>

<Min X="227" Y="118" Z="0" /><Max X="337" Y="211" Z="0" />

</Extent><PersistentID Identifier="{A1-51-2003-1_Topology-

SIGNALLINE-1}"Context="http://www.aveva.com/example/P&amp;ID" /

><Connection FromID="ID_73" ToID="ID_87" ToNode="2" />

</SignalLine>

• StartDiameterThis is the internal bore for a segment or a PipingNetworkSystem at its source.

Child elements:

None

Attributes:

Example:

<StartDiameter Value="4" /><StartDiameter Value="200" Units="mm" />

• StringA string value used to annotate a drawing. Each element represents a single line of text.

Child elements:

None

Attributes:

Example:

<String Value="1. my text annotation"/><String Value="2. a second line of text"/>

Attribute Name Required Description

Value Y The bore size

Units N This may be any of the distance units permitted. See Units for permitted values and semantics if not present.

Attribute Name Required Description

Value Y The string value

Units N Any units associated with the string value, not sure how to use this.

12.19:161© 2011 AVEVA Solutions Ltd

Page 786: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• SupplierThis is the name of the supplier for an item.

Child elements:

None

Attributes:

None

Example:<Supplier>My supplier</Supplier>

• SurfaceTo be defined.

• SystemTo be defined.

• TestPressureThe pressure that should be used to test an item

Child elements:

None

Attributes:

Example:<TestPressure Value="60" Units="bar"/>

• TextThis defines the textual annotation for a drawing. The text may be provided in an attribute, referenced using attributes on this item, referenced on attributes of another item or provided as a set of String elements. The text itself can be marked up using <b>text</b>, <i>text</i> and <u>text</u> for bold, italic and underlined styles. The '<' and '>' characters have to be escaped in this case.

Child elements:

Attribute Name Required Description

Value Y The pressure

Units N This may be any of the pressure units permitted. See Units for permitted values and semantics if not present.

Element Name Cardinality Description

Presentation 1 The style to use to draw the text.

Extent 1 The minimum bounding rectangle around the text.

12.19:162© 2011 AVEVA Solutions Ltd

Page 787: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Position 1 The position of the text

String 0..* Used when the text contains a line break.

GenericAttributes 0..* Any application specific attributes, this could include attributes that contain the text content to write.

Attribute Name Required Description

NumLines N The number of text lines being represented. If not present then a value of 1 is assumed.

String N If present this is the text to be drawn. If the text contains a line break then it should be split into the String child elements instead of being in the attribute or the line break character replaced with an appropriate character reference.

Font Y The font family name to use.

Justification The location of Position within the Text to be written. Where the text is on multiple lines then Justification denotes the location of Position for the first line of text.

One of the following:

LeftTop LeftCenter LeftBottom CenterTop CenterCenter CenterBottom RightTop RightCenter RightBottom

Defaults to LeftBottom if not provided.

Width Y The full width of the Text string once rendered

Height Y The full height of the Text string once rendered

TextAngle This is the angle that the base line of the text string makes with the positive X axis measured anticlockwise in degrees.

Element Name Cardinality Description

12.19:163© 2011 AVEVA Solutions Ltd

Page 788: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Example:

<Text String="4&quot;-B-902-A3B" Font="romans" Justification="CenterCenter" Width="19.2"Height="2.5" TextAngle="90" SlantAngle="0"><Presentation LineType="Solid" LineWeight="1"

Color="160" R="0" G="0.4" B="1" /><Extent>

<Min X="331.98850197" Y="154.37335742" Z="0" /><Max X="334.48850197" Y="182.19944438" Z="0" />

</Extent>

SlantAngle This is the angle, in degrees, of slant of the text characters measured clockwise from the positive Y axis. E.g. for the character I it is the angle that the vertical stroke makes with the positive Y axis.

ItemID If provided then the text string is to be constructed from the attributes of another element. The ID may be provided as the ID of the element, the PersistentID/@Identifier or the TagName of the element. See TagName Referencing.

Set If the text is to be obtained from a child of a GenericAttributes element then the set name for the GenericAttributes element may be provided to avoid ambiguity.

DependantAttribute The template for the textual contents if obtaining the text from referenced attributes.

The value of the DependantAttribute can contain a single attribute or a list of Attributes and explicit text. IF a single attribute is referenced it may appear just as the attribute name. Where multiple attributes or explicit text is used the attribute names are contained in square brackets. E.g “[Tagprefix]-[Tagnumber][Tagsuffix]”.

The search order will be the Attributes of the PlantItem, ItemAttributes then GenericAttributes of the Text followed by the GenericAttributes of the parent or the object explicitly identified by the ItemID. The first occurrence of the named Attribute will be used, there is no mechanism for handling multiple attributes of the same name.

Attribute Name Required Description

12.19:164© 2011 AVEVA Solutions Ltd

Page 789: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Position><Location X="333.238501971" Y="154.373357424"

Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Text><Text Font="Arial" Justification="LeftBottom" Width="17.2678"

Height="2.032" TextAngle="90" DependantAttribute="[FluidSystem][OperFluidCode]"><Presentation Layer="HiddenObjects" LineType="0"

LineWeight="0" Color="Black" R="0" G="0" B="0"/><Extent>

<Min X="262.83575736" Y="344.08495775" Z="0"/><Max X="264.86775736" Y="369.5594541" Z="0"/>

</Extent><Position>

<Location X="264.867757356" Y="344.08495775" Z="0"/>

<Axis X="0" Y="0" Z="1"/><Reference X="1" Y="0" Z="0"/>

</Position></Text>

<Text Font="Arial" Justification="LeftBottom" Width="17.2678"

Height="2.032" TextAngle="90" DependantAttribute="[FluidSystem][OperFluidCode]"><Presentation Layer="HiddenObjects" LineType="0"

LineWeight="0" Color="Black" R="0" G="0" B="0"/><Extent>

<Min X="262.83575736" Y="344.08495775" Z="0"/><Max X="264.86775736" Y="369.5594541" Z="0"/>

</Extent><Position>

<Location X="264.867757356" Y="344.08495775" Z="0"/>

<Axis X="0" Y="0" Z="1"/><Reference X="1" Y="0" Z="0"/>

</Position></Text>

<Text String="&lt;u&gt;V-3504&lt;/u&gt;" Font="Arial" Justification="LeftBottom" Width="16.9333"

Height="3.52778" TextAngle="0" SlantAngle="0" >

12.19:165© 2011 AVEVA Solutions Ltd

Page 790: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Presentation Layer="Labels" LineType="0" LineWeight="0"

Color="White" R="1" G="1" B="1" /><Extent>

<Min X="510.90356225" Y="169.95252717" Z="0" /><Max X="544.24108325" Y="173.48030717" Z="0" />

</Extent><Position>

<Location X="510.903562254" Y="169.952527166" Z="0" />

<Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Text>

• TransactionA record of a change to an item

Child elements:

Attributes:

Example:

<Transaction Type="to modify" Date="2007-06-10" Time="10:30:32" CompanyName="My company" Person="Me">

Element Name Cardinality Description

Remark 0..* A comment describing the change.

GenericAttributes 0..* Any application specific attributes

Attribute Name Required Description

Type N One of the following;

to approve to check to copy to create to modify to request to release

Date N A date type (YYYY-MM-DD)

Time N A time type (HH:MM:SS) (See http://www/w3.org for full details including time zones)

CompanyName N A free form string (see Character encoding)

Person N A free form string (see Character encoding)

12.19:166© 2011 AVEVA Solutions Ltd

Page 791: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Remark>Amended Nozzle parameters for new specification</Remark><Remark>WP2134</Remark>

</Transaction>

• TrimmedCurveAn arc based on a circle or ellipse definition

Child elements:

Attributes:

Example 0-90:

<Circle Radius="2"><Presentation Layer="1" LineType="Solid" LineWeight="0.3 mm" Color="Grey" R="0.7" G="0.7" B="0.7" /><Extent>

<Min X="-0.94858965624" Y="-1.8918151853" Z="0" /><Max X="0.95634162094" Y="1.9180157898" Z="0" />

</Extent>

Element Name Cardinality Description

Circle 0..1 Only present if Ellipse isn’t present. The base Circle used to define the arc.

Ellipse 0..1 Only present if Circle isn’t present. The base ellipse used to define the arc.

GenericAttributes 0..* Any application specific attributes

Attribute Name Required Description

StartAngle Y The rotation around the circle/ellipse to start the arc from. 0 = east.

The angle is specified in degrees (0-360) measured anti-clockwise.

EndAngle Y The rotation around the circle/ellipse to end the arc at. 0 = east.

The angle is specified in degrees (0-360) measured anti-clockwise.

12.19:167© 2011 AVEVA Solutions Ltd

Page 792: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Position><Location X="0" Y="1" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Circle><TrimmedCurve StartAngle="0" EndAngle="90">

<Circle Radius="2"><Presentation Layer="1" LineType="Solid" LineWeight="0.2 mm" Color="Red" R="1" G="0" B="0" /><Extent>

<Min X="-0.94858965624" Y="-1.8918151853" Z="0" />

<Max X="0.95634162094" Y="1.9180157898" Z="0" /></Extent><Position>

<Location X="0" Y="1" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="1" Y="0" Z="0" />

</Position></Circle></TrimmedCurve>

Example 0-90 with a 90 degree rotation:

<Ellipse PrimaryAxis="2" SecondaryAxis="1"><Presentation Layer="1" LineType="Solid" LineWeight="0.3 mm" Color="Grey" R="0.7" G="0.7" B="0.7" /><Extent>

<Min X="-0.94858965624" Y="-1.8918151853" Z="0" /><Max X="0.95634162094" Y="1.9180157898" Z="0" />

</Extent><Position>

<Location X="5" Y="11" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="0" Y="1" Z="0" />

</Position></Ellipse><TrimmedCurve StartAngle="0" EndAngle="90">

<Ellipse PrimaryAxis="2" SecondaryAxis="1">

12.19:168© 2011 AVEVA Solutions Ltd

Page 793: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Presentation Layer="1" LineType="Solid" LineWeight="0.2 mm" Color="Red" R="1" G="0" B="0" /><Extent>

<Min X="-0.94858965624" Y="-1.8918151853" Z="0" />

<Max X="0.95634162094" Y="1.9180157898" Z="0" /></Extent><Position>

<Location X="5" Y="11" Z="0" /><Axis X="0" Y="0" Z="1" /><Reference X="0" Y="1" Z="0" />

</Position></Ellipse>

</TrimmedCurve>

Example 0-90 with an inverted z-axis:

<Ellipse PrimaryAxis="2" SecondaryAxis="1"><Presentation Layer="1" LineType="Solid" LineWeight="0.3 mm" Color="Grey" R="0.7" G="0.7" B="0.7" /><Extent>

<Min X="-0.94858965624" Y="-1.8918151853" Z="0" /><Max X="0.95634162094" Y="1.9180157898" Z="0" />

</Extent><Position>

<Location X="0" Y="16" Z="0" /><Axis X="0" Y="0" Z="-1" /><Reference X="1" Y="0" Z="0" />

</Position></Ellipse><TrimmedCurve StartAngle="0" EndAngle="90">

<Ellipse PrimaryAxis="2" SecondaryAxis="1"><Presentation Layer="1" LineType="Solid" LineWeight="0.2 mm" Color="Red" R="1" G="0" B="0" /><Extent>

<Min X="-0.94858965624" Y="-1.8918151853" Z="0" />

<Max X="0.95634162094" Y="1.9180157898" Z="0" /></Extent><Position>

<Location X="0" Y="16" Z="0" /><Axis X="0" Y="0" Z="-1" />

12.19:169© 2011 AVEVA Solutions Ltd

Page 794: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

<Reference X="1" Y="0" Z="0" /></Position>

</Ellipse>

</TrimmedCurve>

• UnitsOfMeasureThis element specifies the default units of measure for the file for each type of measured value.

Child Elements:

None

Attributes:

Example:<UnitsOfMeasure Distance="Inch" />

• WallThicknessThe thickness of the element construction.

Child elements:

None

Attribute Name Required Description

Distance N See Units for permitted distance values. Default value is ‘Millimetre’.

Area N See Units for permitted distance values. Default value is 'SquareMetres'.

Angle N See Units for permitted angle values. Default value is ‘Degree’.

Temperature N See Units for permitted temperature values. Default value is ‘DegreeCelsius’.

Pressure N See Units for permitted pressure values. Default value is ‘Bar’.

Volume N See Units for permitted volume values. Default value is 'CubicMetres'.

Weight N See Units for permitted weight values. Default value is ‘Kilogram’.

12.19:170© 2011 AVEVA Solutions Ltd

Page 795: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

Attributes:

Example:<WallThickness Value="4" Units="mm"/>

• WeightThe weight of the item.

Child elements:

None

Attributes:

Example:<Weight Value="6" Units="oz"/>

• WeightsDataChild elements:

Attributes:

None

Example:

<WeightsData><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight><ControlPointWeight>1</ControlPointWeight>

Attribute Name Required Description

Value N The thickness value. Nb this is a string type and so could be represented in many ways.

Units N The units of measure (See Units for permitted values). If not present then this defaults to the units specified by PlantInformation/UnitsOfMeasure.

Attribute Name Required Description

Value N The weight value.

Units N The units of measure (See Units for permitted values). If not present then this defaults to the units specified by PlantInformation/UnitsOfMeasure.

Element Name Cardinality Description

ControlPointWeight 0..*

12.19:171© 2011 AVEVA Solutions Ltd

Page 796: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

</WeightsData>

12.19:172© 2011 AVEVA Solutions Ltd

Page 797: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.7 Format of the Excel Interface Spreadsheet

9.7.1 The Spreadsheet FormatsThe Excel Interface spreadsheet can be generated in two formats: Item Type and Item Group. Each format has a different set of worksheets:

• If a spreadsheet is in the Item Type format, data for each item type that was exported is displayed on its own worksheet.

• If a spreadsheet is in the Item Group format, item type data is grouped into item categories: pipes, instruments, equipment, valves, line fittings, reducers, nozzles and off-sheet connectors. There is a worksheet for each category.

In both formats, there is also a worksheet for drawing data.

The format is selected on the Excel Interface Configuration Category of the AVEVA P&IDProject Administration program.

9.7.2 Item WorksheetsThe first column of every item worksheet is the HANDLE column. This displays the unique identifier of each item on the worksheet. This must not be edited.

Typical items are listed after the item that is typical of them. They will have the same handle as that of the representative item, followed by a #. The first typical item handle will be followed by a # only. Further items will be followed by a # and a number, i.e. #1, #2 etc.

The second column of every item worksheet is the DRAWING column. This displays the number of the drawing on which each item is located. Changes made in this column are ignored.

Subsequent columns display item data for editing. For guidance on editing item data, refer to the Editing P&ID Data in an Excel Spreadsheet procedure.

12.19:173© 2011 AVEVA Solutions Ltd

Page 798: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

The third column displays the drawing grid in which each item is located. The next three columns, if applicable to the category of item, display coordinates of the item and its angle of rotation.

For tagged items, the item tag numbers are displayed in the next column or columns, followed where applicable by the offset from the item and angle of rotation of the label.

Other columns include item types, the parent tags of nozzles, the upstream and downstream sizes of reducers, the drawing number that off-sheet connectors reference, pipe attributes such insulation and paint codes, and instrument loop and alarm details.

9.7.3 Drawing Data WorksheetsThe Drawing Data worksheet displays the drawing number, revision, client drawing number and the drawing title/description text. Changes to the drawing number can be made using this worksheet.

9.7.4 NEW FieldsEach column in a worksheet containing values that can be edited has a corresponding NEW column in which new values can be entered instead of editing the current values.

For example, in a worksheet containing a TAG column, there will also be a NEW TAG column. The NEW fields are provided to enable users to compare the original values with the modified ones.

Whether or not data is to be imported from NEW columns is specified by project configuration for each item group.

Note that if an item type is set by project configuration to import from the NEW columns, all validated NEW fields for that item type must be populated. If any validated NEW fields are left blank, these will be regarded as invalid by the import process as they do not contain valid values.

9.7.5 Insertable and Updateable FieldsSome worksheet fields are insertable, others are only updateable (assuming they are not read-only). Updateable fields can only be amended in a spreadsheet. In other words, if they do not already exist on a drawing (and therefore can be exported to a spreadsheet), they can only be changed in a spreadsheet, not added.

Insertable fields are label fields that can be added as new labels for items. When the spreadsheet is imported, these new labels will be place on the drawing. Columns in which

12.19:174© 2011 AVEVA Solutions Ltd

Page 799: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

insertable labels can entered can be identified on a spreadsheet as the subsequent columns will columns used to add the offset and rotation properties of any new labels. For example:

9.7.6 Validated RowsWhen changed data is imported back into a AVEVA P&ID drawing it is validated. After validation, rows in the spreadsheet containing errors are displayed in red. In this example, the value in the SIZE field of the first item row is invalid:

Rows in the spreadsheet containing valid changes displayed in green:

12.19:175© 2011 AVEVA Solutions Ltd

Page 800: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.8 Setting up AVEVA P&ID to Connect with VPE WorkbenchThe following configuration is required in AVEVA P&ID in order to set up the interface between AVEVA P&ID and AVEVA VPE Workbench (see 7.5: Exporting Data to a VPE Workbench Database).

9.8.1 Installing the VPE Middle Tier During the installation of AVEVA P&ID, Workbench Components should be installed on Middle Tier:

12.19:176© 2011 AVEVA Solutions Ltd

Page 801: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• Configuring the Windows service for EngAPI

- Checking the Windows status of the EngAPI Service

Run “%SystemRoot%\system32\services.msc /s” to open services running on the machine:

Check that the service status of “AVEVA PID ENGAPIService” is "Started".

- Changing Ports

Run “C:\Aveva\P&ID\Aveva EngAPI Service\ ServiceEditor.exe”.

Using the dialog that is then displayed, as required, change the port used by the service and restart the service.

12.19:177© 2011 AVEVA Solutions Ltd

Page 802: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

• Starting the EngAPI ServiceTo start up the service successfully, users must enter the same user name and password used during the installation of the service, because the settings for the service are saved at the local machine level in the registry.

12.19:178© 2011 AVEVA Solutions Ltd

Page 803: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.8.2 Configuring the AVEVA P&ID ClientThis procedure is carried out using the VPE Workbench Configuration Category of the AVEVA P&ID Project Administration program.

The VPE.ini file identified in the VPE Config File field provides a list of the available VPE Workbench projects. This file is provided by VPE Workbench. Users may copy this file to their local machines.

The VPE Service Path is the http path used to connect to the EngAPI service. After creating a new project, the user is expected to change the server “WBServer” and port “8080” settings to the middle tier server name and port.

The Test button is provided to check whether the service is ready to use. This test button will check whether the service:

• exists at path provided by VPE Service Path• is started on VPE Middle Tier• can connect to VPE Workbench

The Publisher Folder is the location to which synchronized files from the AVEVA P&ID project's output folder are copied. This folder will be continuously watched by the Publisher, and when synchronized files are copied to this folder; it will publish them to the Subscriber. The Publisher folder name should match with that of the Publisher configuration file.

The user can select the Database Project from available list. The project list will be populated with those listed in the VPE.ini file.

12.19:179© 2011 AVEVA Solutions Ltd

Page 804: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

The Export to VPE Workbench check box controls the default setting of the Export Data to Publishing Area checkbox on the Synchronise dialog.

After loading data into VPE Workbench, Subscriber will send e-mails reporting the status of load process. The e-mail addresses will depend on machine user ids of P&ID users. If a user id is not in the e-mail address table then e-mail will be sent to the USERNAME_DEFAULT e-mail address. Typically, the format of these e-mails will be as below:

9.8.3 SynchronisingThe Synchronise procedure (see 8.8.5: Synchronising Data with a VPE Workbench Database) will copy the files from the AVEVA P&ID project's output folder to Publisher folder if the Export Data to Publishing Area checkbox is checked on the Synchronise dialog. On successfully copying the files, the Publisher service will export these files to the Subscriber.

12.19:180© 2011 AVEVA Solutions Ltd

Page 805: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.8.4 Batch Loading data to VPE Workbench

The Select Drawings to Publish window lists the drawings in the "Vantage" folder. Users can select drawings from list and click on the > button to copy these drawings to Publisher folder. They will be displayed in the Publishing Area list.

The >> button will copy all the listed drawings into the Published folder.

On successfully copying the files, the Publisher service will export these files to the Subscriber.

If middle tier has older VPE Workbench versions like 5.6 or 5.7 installed on it, and Publisher is not installed on the machine, drawings can be loaded to VPE Workbench from the Publisher folder by:

1. Checking the Using Workbench Legacy Version (5.6/5.7) checkbox. This will enable the Login button.

2. Selecting the files to be loaded as described above, using the > and >> buttons (the Clear button will delete selected files from Publishing Area list).

3. Logging in. After a successful login, the Load button will be enabled. 4. Clicking the Load button to load the drawings to VPE Workbench (5.6/5.7). The load

progress will be shown in the progress bar, and status messages will be displayed in the text box below.

5. The View Log button will open a log file containing the status messages from VPE Workbench load process.

6. The files successfully loaded to VPE Workbench will be removed from the Publishing area.

12.19:181© 2011 AVEVA Solutions Ltd

Page 806: aveva p&id

AVEVA P&ID 12.1 User GuideAppendices

9.9 Setting up PDMS to Connect with P&IDThe following configuration is required in PDMS in order to set up the interface between AVEVA P&ID and PDMS (see 7.3: Exporting to PDMS Schematic Databases).

• In the Admin module, ensure the “Toolbox” module is defined and that it is set to open Schematic type databases in RW mode (as defined in the supplied file MODMAC.MAC, with the standard PDMS install).

To define the TOOLBOX module if it does not already exist, enter the following at the command prompt:

MODULE 95 TOOLBOX

M DESI RW

M NSEQ RW

M ISOD R

M SCHE RW

M CATA R

M PROP R

M DICT R

M MANU R

M DESI DEFAULT

M TRAN RW

BUFFER 12800000

If the Toolbox module already exists but the Schematic DB is not set to open in RW mode, then enter:

edit module 95 mode SCHE RW • The Schematic Model database and the Catalogue Data database should be set to

multi-write implicit, to allow the loading PDMS and P&ID at the same time.

For instance, in the SAM project the following databases must be set to multi-write:

- SAMPLE/DESI

- ADMIN/REFDATA

12.19:182© 2011 AVEVA Solutions Ltd

Page 807: aveva p&id

Index

AVEVA P&ID 12.1 User Guide

AAbout this User Guide . . . . . . . . . . . . . . . 1:1Adding a Title to a Drawing and entering Drawing Sheet Attributes . . . . . . . . . . . . . . . . . . . 8:2Adding Custom Lisp Routines to AVEVA P&ID 2:199Adding Elbows to a Line . . . . . . . . . . . . 8:64Adding Equipment Headers . . . . . . . . . 8:82Adding new multi line styles in AVEVA P&ID 2:200Adding Notes to Items . . . . . . . . . . . . . 8:147Adding Pipe and Signal Line Segments 8:61Adding Pipe Destination Text . . 6:32, 8:135Adding User-Defined Attributes . . . . . . 6:36Administration of Assemblies . . . . . . . 2:195AE Integration Configuration Category 2:183AI Integration Configuration Category . 2:177AlphaNumeric/Numeric equivalent Size 2:63Annotation Assemblies . . . 6:42, 8:38, 8:226Applying Tracing to Inline Items . . . . . . 8:54Applying Tracing to Pipes . . . . . . . . . . . 8:54Assemblies . . . . . . . 6:22, 6:42, 8:38, 8:226Assigning a New Branch Id to a Pipe . 8:232Assigning P&ID Item Types and Symbol Data to AutoCAD Blocks . . . . . . . . . . . . . . . . . . . 5:6Assigning P&ID Pipe Types to AutoCAD Line Types . . . . . . . . . . . . . . . . . . . . . . . . . . 5:11Assigning P&ID Signal Line Types to AutoCAD Line Types . . . . . . . . . . . . . . . . . . . . . . 5:11Assigning P&ID Symbol Names to AutoCAD Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:8Assigning Unassigned Items to a Drawing 4:23Associations between Items . . . . . . . . 8:229Auto Save . . . . . . . . . . . . . . . . . . . . . . 2:148

Auto Save Settings . . . . . . . . . . . . . . . 2:203AutoCAD Defaults set by AVEVA P&ID 9:24AutoCAD Design Centre . . . . . . . . . . . 4:36AutoCAD Drafting Guidelines . . . . . . . . . 5:3Auto-Labelling . . . . . . . . . . . . . . . . . . 2:150Automatic Drawing Configuration . . . . . . 3:2Automatic Suffix Assignment for Duplicate In-strument Tags . . . . . . . . . . . . . . . . . . . 6:19Automatic Tagging 2:132, 2:172, 6:25, 6:34, 8:143AVEVA Electrical 2:183, 4:21, 4:24, 7:2, 8:206AVEVA Instrumentation 2:177, 4:21, 4:24, 7:2, 8:206AVEVA NET . . . . . . . . . . . 2:178, 7:8, 8:209AVEVA NET Configuration Category . 2:178AVEVA P&ID Colouring Utility . . . . . . 8:173AVEVA P&ID Drawing Upgrade Utility . . 5:4

Assigning P&ID Item Types and Symbol Data to AutoCAD Blocks . . . 5:6

Assigning P&ID Pipe Types to AutoCAD Line Types . . . . . . . . . . . . 5:11

Assigning P&ID Signal Line Types to Auto-CAD Line Types . . . . . . . . 5:11

Assigning P&ID Symbol Names to AutoCAD Blocks . . . . . . . . . . . . . . . . . 5:8

Starting the AVEVA P&ID Drawing Upgrade Utility . . . . . . . . . . . . . . . . . . 5:4

AVEVA P&ID Files . . . . . . . . . . . . . . . . . 9:1AVEVA P&ID Item Types and Label Types 9:18AVEVA P&ID Procedures . . . . . . . . . . . 8:1AVEVA P&ID Tool Palette 2:204, 4:36, 8:16AVEVA P&ID Upgrade Utility . . . . . . . . . 2:2Avoiding Problems when using Client Symbolo-gy . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:185

12.1© 2011 AVEVA Solutions Ltd Index page i

Page 808: aveva p&id

AVEVA P&ID 12.1 User Guide

BBalloons . . . . . . . . . . . . . . . . . . . . . . . . 8:31Batch Load to Workbench . . . . . . . . . . . 2:19Branch Id . . . . . . . . . . . . . . . . . . . . . . . 8:232Branches . . . . . . .6:9, 8:45, 8:59, 8:66, 8:67Breaking Lines . . . . . . . . . . . . . . . . . . . 8:56Breaking Signal Lines and Process Links 8:57Breaks . . . . . . . . . . . . . . . . 2:70, 8:12, 8:133Breaks and Inline Breaks . . . . . . . . . . . 6:31

CCascading Changes Through a Pipe Run 2:73, 6:32Changing AVEVA P&ID Settings . . . . . 8:11Changing Branches to Pipes . . . . . . . . 8:67Changing Inherited Values . . . . . . . . . . 6:34Changing Pipe Styles . . . . . . . . . . . . . . 8:53Changing Pipes to Branches . . . . . . . . 8:66Changing Pipes to Branches and Branches to Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:66Changing Signal Line Styles . . . . . . . . . 8:55Changing the Association of a Pipe Label 8:146Changing the Colours of Multiple Items 8:173Changing the Length of Lines . . . . . . . . 8:63Changing the Owning Pipes of Branches 8:67Changing Units on a Project . . . . . . . . 2:184Character Encoding . . . . . . . . . 9:27, 9:100Checking for Corrupted Items . . . . . . . 8:183Client Symbology . . . . . . . . . . . . . . . . 2:185Clouds . . . . . . . . . . . . . . . . 6:22, 6:45, 8:172Code Offset from Symbol Origins . . . . 2:129Colouring Utility . . . . . . . . . . . . . . . . . . 8:173Complex Linetypes . . . . . . . . . . . . . . . 2:204con file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:17Connecting Pipe Flags . . . . . . . . . . . . 8:122Connecting Pipes to Nozzles and Equipment 8:68Connecting to a P&ID Reports Database 8:187Connecting to a VPE Workbench Database 8:200Connector Label Settings . . . . . . . . . . 2:143Context Sensitive Menus . . . . . . . . . . . . 4:6Convert Project Label Units . . . . . . . . . 8:10Copying a Single Owned Item . . . . . . 8:158Copying and Pasting . . . . . . . . . . . . . . . 8:16Copying Drawing Objects and Labels . 8:156Corrupted Items . . . . . . . . . . . . 6:47, 8:183Creating a New Drawing . . . . . . . . . . . . . 6:4Creating a New Symbol . . . . . . . . . . . 2:184Creating a New Symbol, Editing a Symbol 4:14Creating Assemblies . . . . . . . . . . . . . . 8:226Creating Instrument Loops . . . . . . . . . . 8:98

Creating Item Associations . . . . . . . . 8:228Creating New Signal Line Styles . . . . . 2:87Creating Pipe Groups . . . . . . . . . . . . . 8:114Creating User-Defined Lists of Values . 2:65Custom Label . . . . . . . . . . . . . . . . . . . 8:122Customisation Guide . . . . . . . . . . . . . 2:195Customising the AVEVA P&ID Tool Palette 2:204

DData Transfer . . . . . . . . . . . . . . . . . . . . . 7:1DataSets (User Defined Attributes) . . 2:168DataSets (User-Defined Attributes) . . . 6:36Default OSnap . . . . . . . . . . . . . . . . . . 2:147Define Split labels and offset for symbol 2:83Defining a New Pipe Style . . . . . . . . . 2:189Defining a New Signal Line Type . . . . 2:189Defining a New Tracing Style . . . . . . . 2:195Deleting Error Messages . . . . . . . . . . 8:235Deleting Items . . . . . . . . . . . . . . . . . . . 6:46Deleting Pipe and Signal Line Segments 8:62Deleting Validation Error and Warning Messages 8:200Descriptors . . . . . . . . . . . . . . . . . . . . . . 6:18Design Data Templates 6:42, 6:45, 8:38, 8:173, 8:226Detecting Corrupted Items . . . . . . . . . . 6:47Dialog Box Field Labels . . . . . . 2:129, 2:152Dialog Box Field Labels and List of Values . 2:112Disconnecting from a VPE Workbench Database 8:201Disconnecting Pipe Flags . . . . . . . . . . 8:128Disconnecting Pipes from Nozzles and Equip-ment . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:69Display Instrument Labels at Pipe Destination 2:83Display Label Format . . . . . 2:80, 2:143, 8:8Displaying the Symbol Explorer . . . . . . . 4:9Drawing Configuration Category . . . . . 2:30

Grid Sub-Category . . . . . . . . . . . . . 2:31Labels Sub-Category . . . . . . . . . . . 2:33Layers Sub-Category . . . . . . . . . . . 2:35Settings Sub-Category . . . . . . . . . . 2:37Validation Sub-Category . . . . . . . . 2:39

Drawing Details - .drg file . . . . . . . . . . . . 9:8Drawing Frame Settings . . . . . . . . . . . . 2:31Drawing Labels . . . . . . . . . . . . . . . . . . 2:33Drawing Menus . . . . . . . . . . . . . . . . . . . 4:7Drawing P&IDs . . . . . . . . . . . . . . . . . . . . 6:1Drawing Page . . . . . . . . . . . . . . . . . . . . 4:37Drawing Pipes . . . . . . . . . . . . . . . . . . . 8:45Drawing Pipes and Connections . . 6:9, 8:45

12.1© 2011 AVEVA Solutions Ltd Index page ii

Page 809: aveva p&id

AVEVA P&ID 12.1 User Guide

Drawing Pipes and Process Links . . . . . 6:9Drawing Process Links . . . . . . . . . . . . . 8:48Drawing Revision Clouds . . . . . . . . . . 8:172Drawing Sheet Attributes . . . 6:23, 6:33, 8:2Drawing Signal Lines . . . . . . . . . 6:10, 8:54Drawing Upgrade Utility . . . . . . . . . . . . . 5:4drg file . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:8Dynamic Labelling . . . . . . . . . . . . . . . . . 6:44Dynamic Labels . . . . . . . . . . . . . 6:13, 6:27

EEditing Non-AVEVA P&ID Text . 6:13, 8:140Editing P&ID Data in an Excel Spreadsheet 8:215Editing Pipe Styles . . . . . . . . . . . . . . . . 2:64Electrical Equipment . . . . . . 6:15, 8:19, 8:79Element Definitions . . . . . . . . . . 9:31, 9:102Engineering Explorer . . . . . . . . . . . . . . . 4:3Entering Pattern Labels . . . . . . . . . . . 2:103Entering Symbol Data . . . . . . . . . . . . . . 2:53equ file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:9Equipment 2:109, 6:14, 8:7, 8:17, 8:68, 8:69, 8:74, 8:79, 8:82Equipment Classification . . . . . . . . . . . 2:111Equipment Configuration Category . . . 2:109

Labels Sub-Configuration Category 2:116Settings Sub-Category . . . . . . . . . 2:110Validation Sub-Category . . . . . . . 2:121

Equipment Data from VPE Workbench 2:111Equipment Design Data . . . . . . . . . . . . . 7:5Equipment Information - .equ file . . . . . . 9:9Equipment Label Format . . . . . . . . . . . 2:118Equipment Label Position . . . . . . . . . . 2:117Equipment Label Symbol . . . . . . . . . . 2:119Equipment With Trim . . . . . . . . . . . . . . 6:15Error and Warning Messages . 8:195, 8:235Excel . . . . . . . . . . 7:10, 8:212, 8:215, 8:218Excel Interface Configuration Category 2:154Existing Patterns . . . . . . . . . . . . . . . . . 2:102Existing Tables . . . . . . . . . . . . . . . . . . . 2:20Exiting AVEVA P&ID . . . . . . . . . . . . . . . . 6:4Explorer Display Options . . . . . . . . . . . . 4:1Export to Excel - excelout . . . . . . . . . . 2:155Exporting Data to a VPE Workbench Database 7:6Exporting Data to an AVEVA P&ID Reports Da-tabase . . . . . . . . . . . . . . . . . . . . . 7:1, 8:183Exporting Data to AVEVA NET . . . . . . . . 7:8Exporting Data to Excel . . . . . . . . . . . 8:212Exporting Data to ISO 15926 Files 7:9, 8:210Exporting to AVEVA Electrical . . . . . . . . 7:2Exporting to AVEVA Instrumentation . . . 7:2Exporting to PDMS Schematic Databases 7:3

FFeatures of AVEVA P&ID . . . . . . . . . . . . 1:2File Document Structure . . . . . . . . . . . 9:94Filtering Unassigned Items . . . . . . . . . . . 4:6Flow Arrows . . . . . . . . . . . . . . . . . 2:71, 8:11Flow Elements . . . . . . . . . . . . . . . 6:19, 8:34

GGeneral Editing . . . . . . . . . . . . . . . . . . 6:45General Instruments . . . . . . . . . . . . . . . 6:18General Valves . . . . . . . . . . . . . . . 6:15, 8:86Generating a Mapping File . . . . . . . . . . . 8:2Geometries (Axis and Reference) 9:27, 9:99Get Work . . . . . . . . . . . . . . . . . . . . . . . 4:27Globally Editing non-Pipe Labels . . . . 8:148Good Drawing Practice . . . . . . . . . . . . . 3:1Graphical Assemblies . . . 6:42, 8:38, 8:226Graphical User Interface . . . . . . . . . . . . 4:1Grid Settings . . . . . . . . . . . . . . . . . . . . 2:32Grid Sub-Category . . . . . . . . . . . . . . . . 2:31Guidelines for Drawing Process Links . 8:51

II/O Address Data . . . . . . . . . . . . . . . . . . 7:5I/O Data . . . . . . . . . . . . . . . . . . . . . . . . 6:21I/O Label Position . . . . . . . . . . . . . . . . 2:101I/O Rockets . . . . . . . . . . . . . . . . 6:21, 8:107Implementing Configuration Changes . . 8:6Import Symbols . . . . . . . . . . . . . . . . . . 2:51Import to P&ID - excelin . . . . . . . . . . . 2:155Imported I/O Data . . . . . . . . . . . . . . . . . 6:21Importing Data from Excel . . . . . . . . . 8:218Importing Equipment Design Data . . . . . 7:5Importing from AVEVA Electrical . . . . . . 7:3Importing from AVEVA Instrumentation . 7:3Importing I/O Address Data . . . . . . . . . . 7:5Importing Instrument Tag/Loop Numbers 7:4Importing VPE Workbench Data . . . . . . 7:1Indicating Pipe Flow . . . . . . . . . . . . . . . 6:11Inheritance 2:72, 2:94, 2:113, 2:127, 2:139, 6:13Inherited Values . . . . . . . . . . . . . . . . . . 6:24Inline Breaks . . . . . . . . . . . . . . . 6:31, 8:133Inline Equipment . . . . . . . . . . . . . . . . . 8:15In-Line Equipment Label Position . . . 2:120In-Line Equipment Label Symbol . . . . 2:120Inline Fittings . . . . . .2:138, 6:16, 8:29, 8:93In-Line Non-Valves - .inv file . . . . . . . . 9:10In-Line Valves Information - .ivl file . . . 9:14Inserting 1-point & 2-point symbols . . . 8:15Inserting Assemblies . . . . . . . . . . . . . . 8:38Inserting Electrical Equipment . . . . . . . 8:19

12.1© 2011 AVEVA Solutions Ltd Index page iii

Page 810: aveva p&id

AVEVA P&ID 12.1 User Guide

Inserting Equipment . . . . . . . . . . . . . . . 8:17Inserting Flow Elements . . . . . . . . . . . . 8:34Inserting Inline Fittings . . . . . . . . . . . . . 8:29Inserting Instrument Valves (Control Valves) 8:24Inserting Instruments (Balloons) . . . . . . 8:31Inserting Miscellaneous Symbols . . . . . 8:36Inserting Nozzles . . . . . . . . . . . . . . . . . 8:21Inserting Symbols . . . . . . . . . . 3:4, 6:6, 8:15Inserting Symbols with Labels . . 6:25, 6:34Inserting Tables of VPE Workbench Data 8:204Inserting Unassigned P&ID Database Items 6:7Inserting Unassigned P&ID Database Pipes 8:46Inserting Unassigned P&ID Database Symbols 8:40Inserting Unassigned VPE Workbench Items 6:7, 8:41Inserting Valves . . . . . . . . . . . . . . . . . . 8:22Insertion Methods . . . . . . . . . . . . . . . . . 8:16Instrument Dialog Labels and List of Values 2:93Instrument Label Position . . . . . . . . . . . 2:99Instrument Loops . . . . 2:96, 4:4, 6:19, 8:98Instrument Panel Dialog Labels . . . . . . 2:93Instrument Panel Label Position . . . . . 2:100Instrument Tag/Loop Numbers . . . . . . . . 7:4Instrument Valves (Control Valves) 6:17, 8:24Instruments . . . . . . . . 2:91, 6:18, 8:31, 8:99Instruments (Balloons) . . . . . . . . . . . . . 8:31Instruments Configuration Category . . . 2:91

Labels Sub-Category . . . . . . . . . . . 2:98Patterns Sub-Category . . . . . . . . . 2:101Settings Sub-Category . . . . . . . . . . 2:92Validation Sub-Category . . . . . . . 2:106

inv file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:10ipc file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:12irm file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:13ISO15926 . . . . . . . . . 7:9, 8:210, 9:25, 9:94ISO15926 (Version 3.2.0) Schema . . . . 9:25ISO15926 (Version 3.3.3) Schema . . . . 9:94isy file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:15Item Associations . . . . . . . . . . . . . . . . 8:228Item Details . . . . . . . . . . . . . . . . . . . . . 8:230Item Types . . . . . . . . . . . . . . . . . . . . . . 9:18Item Types Configuration Category . . . 2:41

Signal Sub-Category . . . . . . . . . . . 2:43Standard Sub-Category . . . . . . . . . 2:41

ivl file . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:14

JJoining Co-linear Pipes . . . . . . . . . . . . . 8:70

LLabel Balloon . . . . . . . . . . . . . . . . . . . . 2:99Label Details . . . . . . . . . . . . . . . . . . . . 2:45Label Format . . . . . . . . . . . . . . . 2:117, 6:18Label Format Validation . . . . . . . . . . . . 6:38Label Inheritance from Owning Pipes . 6:13Label Options . . . . . . . . . . . . . . . . . . . . 2:99Label Positioning . . . . . . . . . . . . . 6:18, 6:21Label Types . . . . . . . . . . . . . . . . . . . . . 9:18Label Types Configuration Category . . 2:45Label Types Grid . . . . . . . . . . . . . . . . . 2:46Label Uniqueness . . . . . . . . . . . . 6:18, 6:28Label Uniqueness Validation . . . . . . . . 6:39Label Validation . . . . . . . . . . . . . . . . . . 6:37Label Validation across all Project P&IDs 6:39Label Validation Across P&IDs . 2:71, 2:96, 2:113, 2:127, 2:147Label Validation Across P&IDs Section 2:140Label Validation against Lists of Valid Values 6:37Label Validation against Specifications 6:41Labelling Assemblies . . . . . . . . . . . . . . 6:22Labelling Clouds . . . . . . . . . . . . . . . . . . 6:22Labelling Electrical Equipment . . . . . . . 8:79Labelling Equipment . . . . . . . . . . . . . . . 6:14Labelling Equipment (with or without Trim) 8:74Labelling General Instruments . . . 6:18, 8:99Labelling General Instruments - Using Pattern Labels . . . . . . . . . . . . . . . . . . . . . . . . . . 6:20Labelling General Valves . . . . . . . 6:15, 8:86Labelling I/O Rockets . . . . . . . . . 6:21, 8:107Labelling Inline Fittings . . . . . . . . . . . . . 8:93Labelling Inline Fittings (Special Piping Items) 6:16Labelling Instrument Valves (Control Valves) 6:17Labelling Instruments with I/P Convertors 6:19Labelling Miscellaneous Items . . . . . . . 6:22Labelling Nozzles . . . . . . . . . . . . . 6:21, 8:83Labelling Pipe Destination Fittings 6:16, 8:96Labelling Pipe Flags . . . . . . . . . . 6:22, 8:122Labelling Pipes . . . . . . . . . 6:26, 6:30, 8:116Labelling Pipes with Breaks and Inline Breaks 6:31Labelling Pipes with Reducers and Reducing Valves . . . . . . . . . . . . . . . . . . . . . . . . . 6:31Labelling Port Valves . . . . . . . . . . 6:17, 8:91Labelling Reducers . . . . . . . . . . . . . . 8:128Labelling Revision Triangles . . . 6:23, 8:110Labelling Stream Diamonds . . . . . 6:16, 8:96Labelling Symbols . . . . . . . . . . . . . . . . 6:12Labelling Symbols and Pipes . . . . . . . . 8:70Labelling System I/O Connections, Interlocks

12.1© 2011 AVEVA Solutions Ltd Index page iv

Page 811: aveva p&id

AVEVA P&ID 12.1 User Guide

and Logic Boxes . . . . . . . . . . . . 6:21, 8:105Labelling Typical Items . . . . . . . . . . . . 8:141Labelling with Data from the P&ID Data Grid 8:138Labelling with VPE Workbench Data . 8:202Labelling/Editing Non-AVEVA P&ID Text 6:13Labels Sub-Category 2:75, 2:98, 2:116, 2:129, 2:150Layers . . . . . . . . . . . . . . . . . . . . . . . . . . 2:35Layers Sub-Category . . . . . . . . . . . . . . 2:35Legacy Settings . . . . . . . . . . . . . . . . . . 2:74Line Fittings . . . . . . . 2:138, 6:16, 8:29, 8:93Line Fittings Configuration Category . . 2:138Line Fittings Label Position . . . . . . . . . 2:139Line Fittings Symbol . . . . . . . . . . . . . . 2:139Link Connectivities Information - .con file 9:17List Item Details . . . . . . . . . . . . . . . . . 8:230List of Values Configuration Category . 2:62

MMain Label . . . . . . . . . . . . . . . . . . . . . 8:144Main Pipe Label Colour . . . . . . . . . . . . . 2:76Main Pipe Labels . . . . . . . . . . . . . . . . . 6:27Merging Pipe Segments . . . . . . . . . . . . 8:62Merging Pipes, Branches and Signal Lines 8:57Mirroring Drawing Objects . . . . . . . . . 8:164Miscellaneous Configuration Category 2:144

Labels Sub-Category . . . . . . . . . . 2:150Settings Sub-Category . . . . . . . . . 2:145Validation Sub-Category . . . . . . . 2:152

Miscellaneous Items . . . . . . . . . . . . . . . 6:22Miscellaneous Settings . . . . . . . . . . . . 2:146Miscellaneous Symbols . . . . . . . . . . . . 8:36Modal Properties Dialogs . . . . . . . . . . . 4:42Model Details . . . . . . . . . . . . . . . . . . . . 9:94Modifying Drawings . . . . . . . . . . . . . . . 8:156Modifying Pipe Label Fields and Cascading Changes Through a Pipe Run . . . . . . . 6:32mon file . . . . . . . . . . . . . . . . . . . . . . . . . 9:18Monitor File - .mon file . . . . . . . . . . . . . 9:18Moving Drawing Objects . . . . . . . . . . . 8:162Multi line styles . . . . . . . . . . . . . . 2:200, 9:1

NNodes . . . . . . . . . . . . . . . . . . . . . . . . . . 6:27Non-AVEVA P&ID Text . . . . . . . . . . . . 8:140Non-Modal Properties Dialog . . . . . . . . 4:46Non-Standard Label Format . . . . . . . . . 6:28Notation . . . . . . . . . . . . . . . . . . . . 9:25, 9:94Notes . . . . . . . . . . . . . . . . . . . . . 6:45, 8:147Notes Information - .nte file . . . . . . . . . . 9:17noz file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:10

Nozzle and Special Piping Items Label Field Val-idation . . . . . . . . . . . . . . . . . . . . . . . . . 2:152Nozzle Information - .noz file . . . . . . . . 9:10Nozzles 2:141, 6:21, 8:21, 8:68, 8:69, 8:83Nozzles Configuration Category . . . . 2:141nte file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:17Null Characters . . . . . . . . . . . . . . . . . . 6:30Number of TAG fields . . . . . . . . . 2:93, 2:111

OOffsheet Connector Configuration Category 2:142Off-Sheet Connectors 2:142, 4:24, 6:22, 8:122Opening a P&ID Reports Database . . 8:188Output File Format . . . . . . . . . . . . . . . . . 9:8Overview of AVEVA VPE P&ID . . . . . . . 1:1

PP&ID Data Grid . . . . . . . 4:21, 8:138, 8:140P&ID Reports . . . . .7:1, 8:183, 8:187, 8:188P&ID Reports Configuration Category . 2:27Page Connectors . . . . . . . 4:24, 6:22, 8:122Panel Reference Labels . . . . . . . . . . . . 6:21Pattern Labels 2:101, 2:134, 6:20, 8:86, 8:99Patterns Components . . . . . . . 2:103, 2:136Patterns Sub-Category . . . . . . . 2:101, 2:134PDMS . . . . . . . . . . . . . . . . . . . . 2:176, 9:182PDMS Cats and Specs Import . . . . . . 2:161PDMS Integration Configuration Category 2:176PDMS Schematic Database 4:26, 7:3, 8:208, 9:182PersistentId Referencing . . . . . . 9:28, 9:100PID.MAP . . . . . . . . . . . . . . . . . . . . . . . . 9:1PID.MLN . . . . . . . . . . . . . . . . . . . . . . . . . 9:1pip file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:16Pipe Creation . . . . . . . . . . . . . . . . . . . . . 3:3Pipe Destination Fittings . . . . . . . 6:16, 8:96Pipe Destination Text . . . . . . . . . 6:32, 8:135Pipe End Styles . . . . . . . . . . . . . . . . . 2:143Pipe Flags . . . . . . .2:142, 4:24, 6:22, 8:122Pipe Flow . . . . . . . . . . . . . . . . . . . 6:11, 8:60Pipe Groups . . . . . . .2:173, 4:5, 6:31, 8:114Pipe Information - .pip file . . . . . . . . . . 9:16Pipe Item Information - .pit file . . . . . . . 9:16Pipe Label Fields . . . . . . . . . . . . . . . . . 6:26Pipe Label Format . . . . . . . . . . . . . . . . 2:78Pipe Label Symbols . . . . . . . . . . . . . . . 2:84Pipe Styles . . . . . . . . . . . . 2:189, 8:13, 8:53Pipe Tag Assemblies . . . . 6:42, 8:38, 8:226Pipes 2:1, 2:67, 3:2, 3:3, 6:9, 6:26, 8:8, 8:45, 8:53, 8:54, 8:56, 8:57, 8:60, 8:61, 8:62, 8:63, 8:64, 8:66, 8:67, 8:68, 8:69, 8:116, 8:144, 8:146,

12.1© 2011 AVEVA Solutions Ltd Index page v

Page 812: aveva p&id

AVEVA P&ID 12.1 User Guide

8:151, 8:152, 8:232Pipes and Symbols . . . . . . . . . . . . . . . . . 3:2Pipes Configuration Category . . . . . . . . 2:67

Labels Sub-Category . . . . . . . . . . . 2:75Settings Sub-Category . . . . . . . . . . 2:68Validation Sub-Category . . . . . . . . 2:84

Piping Sequence . . . . . . . . . . . . . . . . . 8:232pit file . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:16Populate Specification in Database . . . 2:72por file . . . . . . . . . . . . . . . . . . . . . . . . . . 9:18Port Valves . . . . . . . . . . . . . . . . . 6:17, 8:91Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:12Preliminary Procedures . . . . . . . . . . . . . . 8:1Principles and Concepts . . . . . . . . . . . . . 3:1Process Connected Instrument Information - .ipc file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9:12Process Links 2:67, 6:9, 8:48, 8:53, 8:63, 8:64Project Administration Program . . . . . . . 2:6Project Catalogue Editor . . . . . . . . . . . . . 2:8Project Configuration . . . . . . . . . 2:1, 8:235Project Database Configuration Category 2:25Project Definable Fields . . . . . . . . . . . . 2:82Project Drawing Units . . . . . . . . . . . . . 2:184Project Number . . . . . . . . . . . . . . . . . . . 2:13Project Options Overview . . . . . . . . . . . . 2:5Project Paths . . . . . . . . . . . . . . . . . . . . . 2:14Project Profiles . . . . . . . . . . . . . . . . . . 2:204Project Symbols . . . . . . . . . . . . . . . . . 2:184Project Units . . . . . . . . . . . . . . . . 2:14, 8:10Project Upgrade . . . . . . . . . . . . . . . . . . . 2:2Propagating Changes to Pipe Properties 8:127Properties Dialogs . . . . . . . . . . . . 4:42, 4:46Publishing Data to AVEVA NET . . . . . 8:209

QQuick Guide to Drawing P&IDs . . . . . . . . 6:1

RRecovering Project Configuration Settings .8:235Reducer Setting . . . . . . . . . . . . . . . . . . 2:72Reducers . . . . . . . . . . . . . . . . . . 6:31, 8:128Reducing Valve . . . . . . . . . . . . . . . . . . . 8:89Reducing Valves . . . . . . . . . . . . . . . . . . 6:31Reformatting Existing Pipe Labels . . . . 6:26Refreshing P&ID Data Grid Labels . . . 8:140Refreshing VPE Workbench Data . . . . 8:210Regenerating the Drawing . . . . . . . . . 8:228Remote Instrument Information - .irm file 9:13REMOVEUDAS . . . . . . . . . . . . . . . . . 8:154Removing UDAs from Symbols . . . . . 8:154Reversing Pipe and Signal Line Flows . 8:60

Revision . . . . . . . . . . . . . . . . . . . . . . . . 6:45Revision Symbols . . . . . . . . . . . . . . . . 2:150Revision Triangles . . . . . . . . . . . 6:23, 8:110Rotating Drawing Objects . . . . . . . . . 8:167Running AVEVA P&ID in "Save To Model Mode" 2:201

SSave Drawing Copy After Output . . . . . 2:15Save to database on Update . . . . . . . . 2:26Save To Model Mode . . . . . . . . . . . . . 2:201Save Work . . . . . . . . . . . . . . . . . 4:28, 8:208Saving Changes . . . . . . . . . . . . . . . . . . 6:48Selecting Multiple Objects . . . . . . 2:37, 6:11Selecting the Style of New Pipes . . . . . 8:13Selecting the Style of New Signal Lines 8:14Selecting the Tracing Style of New Pipes 8:13Setting a Pipe Label as the Main Label 8:144Setting Labels to Inherit Values from Drawing Sheet Attributes . . . . . . . . . . . . . . . . . . 6:33Setting Properties Sheet fields to inherit previ-ously entered values . . . . . . . . . . 6:23, 6:33Setting Symbols to Inherit Label Data from a Manually Selected Pipe . . . . . . . . . . . 8:151Setting Symbols to Inherit Label Data from Auto-matically Selected Pipes . . . . . . . . . . 8:152Setting Text Options . . . . . . . . . . . . . . . 6:13Setting up AVEVA P&ID to Connect with VPE Workbench . . . . . . . . . . . . . . . . . . . . . 9:176Setting up PDMS to Connect with P&ID 9:182Settings Sub-Category 2:68, 2:92, 2:110, 2:125, 2:145Shared Attribute Definitions . . . . 9:28, 9:100

ComponentClass . . . . . . . . . 9:29, 9:101ComponentName . . . . . . . . . 9:29, 9:101ComponentType . . . . . . . . . 9:29, 9:101ID . . . . . . . . . . . . . . . . . . . . . 9:28, 9:100Revision . . . . . . . . . . . . . . . . 9:30, 9:101Specification . . . . . . . . . . . . 9:29, 9:101Status . . . . . . . . . . . . . . . . . . 9:30, 9:101StockNumber . . . . . . . . . . . . 9:29, 9:101Tag . . . . . . . . . . . . . . . . . . . . . . . . . 9:29TagName . . . . . . . . . . . . . . . . . . . 9:100Units . . . . . . . . . . . . . . . . . . . 9:30, 9:102

Sheet Attributes . . . . . . . . . . . . . . . . . . 2:37Show Associations between Items . . . 8:229Show Unassigned Items in Explorer . . 2:18Signal Line Styles . . . . . . . . . . . . . 8:14, 8:55Signal Line Types . . . . . . . . . . . . . . . . 2:189Signal Lines 2:87, 2:189, 6:10, 8:54, 8:55, 8:56, 8:57, 8:60, 8:61, 8:62, 8:63, 8:64Signal Styles Configuration Category . 2:87Signal Sub-Category . . . . . . . . . . . . . . 2:43

12.1© 2011 AVEVA Solutions Ltd Index page vi

Page 813: aveva p&id

AVEVA P&ID 12.1 User Guide

Single Property Label Format . . . . . . . . 6:28Size Consistency . . . . . . . . . . . . . . . . . 2:72Spec Driven Configuration Category . 2:156Special Piping Items . . . . . . . . . . . . . . . 6:16Split Format . . . . . . . . . . . . . . . . . . . . . . 2:83Split Label Format . . . . . . . . . . . . . . . . . 6:29Splitting off Branches . . . . . . . . . . . . . . 8:59Splitting Pipes and Signal Lines . . . . . . 8:57SQL Database . . . . . . . . . . . . . 6:40, 8:189SQL Server Settings . . . . . . . . . . . . . . . 2:25Standard Pipe Label Format . . . . . . . . . 6:28Standard Sub-Category . . . . . . . . . . . . 2:41Starting and Exiting AVEVA P&ID . 6:4, 6:5Starting the AVEVA P&ID Drawing Upgrade Util-ity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5:4Start-up Routines . . . . . . . . . . . . . . . . 2:195Stretching Drawing Objects . . . . . . . . 8:165Switching off Label Data Inheritance from Pipes 8:152Symbol Editor . . . . . . . . . . 2:52, 2:184, 4:14Symbol Explorer . . . . . . . . . . . . . . 4:9, 8:16Symbol Explorer Pane . . . . . . . . . . . . . . 4:9Symbol Grid . . . . . . . . . . . . . . . . . . . . . 2:52Symbol Search Priority . . . . . . . . . . . . . 2:15Symbol Utility Programs . . . . . . . . . . . 2:185Symbol Viewer . . . . . . . . . . . . . . . . . . . 2:51Symbols Configuration Category . . . . . 2:50Symbols with Labels . . . . . . . . . . 6:25, 6:34Synchronisation . . . . . . . . . . . 8:189, 8:199Synchronising Data with a VPE Workbench Da-tabase . . . . . . . . . . . . . . . . . . . . . . . . . 8:189Synchronising Multiple Drawing Data with VPE Workbench . . . . . . . . . . . . . . . . 2:19, 8:199System I/O Connections, Interlocks and Logic Boxes . . . . . . . . . . . . . . . . . . . . 6:21, 8:105System Output Information - .isy file . . . 9:15

TTable Details . . . . . . . . . . . . . . . . . . . . . 2:21Tag Referencing . . . . . . . . . . . . . . . . . . 9:28Tag Validation . . . . . . . . . . . . . . . . . . . 2:154TagName Referencing . . . . . . . . . . . . 9:100Templates . . . . . . . . . . . . . . . . . . . . . . . . 3:2Text Options . . . . . . . . . . . . . . . . . . . . . 6:13Text Position from Origin . . . . . . . . . . 2:146Text Styles Configuration Category . . . 2:49Titling a Drawing . . . . . . . . . . . . . . . . . . . 6:5Topology . . . . . . . . . . . . . . . . . . . . . . . . 9:96Tracing . . . . . . . . . . . . . . . 2:195, 8:11, 8:54Tracing Lines . . . . . . . . . . . . . . . . . . . . 6:11Tracing Styles . . . . . . . . . . . . . . 2:195, 8:13Transferring Data from AVEVA Instrumentation and AVEVA Electrical . . . . . . . . . . . . . 8:206

Transferring Data to and from Excel . . 7:10Transferring Data to PDMS Schematic Databas-es . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8:208Trim Label . . . . . . . . . . . . . . . . . . . . . . 8:78Turning Automatic Breaks On and Off . 8:12Turning Automatic Flow Arrows On and Off 8:11Turning Automatic Tracing On and Off 8:11Turning Fixed Pipe Label Formatting On and Off 8:13Turning the Display of Ports On and Off 8:12Typical Items . . . . . . . . . . . . . . . 6:42, 8:141Typical Labelling . . . . . . . . . . . . . . . . 2:151

UUDA Assemblies . . . . . . . 6:42, 8:38, 8:226Unassigned Items 4:6, 4:23, 6:7, 8:40, 8:41, 8:46Unassigned Menus . . . . . . . . . . . . . . . . 4:8Unassigned P&ID Database Items 6:7, 8:40, 8:46Unassigned VPE Workbench Items 6:7, 8:41Unique Tags . . . . . . . . . . . . . . . . 2:99, 2:119Updating Equipment Tags . . . . . . . . . . . 8:7Updating PipeTags . . . . . . . . . . . . . . . . . 8:8Updating Spec Driven Data . . . . . . . . . . 8:9Updating UDAs . . . . . . . . . . . . . . . . . . 2:59Upgrade Procedures in AVEVA P&ID . 5:13

Upgrading Blocks to Symbols . . . . 5:18Upgrading Lines to Pipes and Signal Lines

5:13Upgrading Text to Labels . . . . . . . . 5:21Viewing Upgraded Entities . . . . . . . 5:25

Upgrade Specdriven Database Schema 2:26Upgrading AutoCAD Drawings . . . . . . . . 5:1

AutoCAD Drafting Guidelines . . . . . 5:3AVEVA P&ID Drawing Upgrade Utility 5:4Upgrade Procedures in AVEVA P&ID 5:13

Upgrading Blocks to Symbols . . . . . . . 5:18Upgrading Lines to Pipes and Signal Lines 5:13Upgrading Pipes and Symbols from old Projects 2:1Upgrading Text to Labels . . . . . . . . . . . 5:21usd file . . . . . . . . . . . . . . . . . . . . . . . . . 9:17User Access Configuration Category . 2:175User Defined Attributes . . . . . . . . . . . 2:167User Defined Attributes Configuration Category 2:167User Defined Directives . . . . . . . . . . . 2:148User Defined Sheet Attribute . . . . . . . . 2:37User Start-up Routines . . . . . . . . . . . . 2:195User-Defined Attributes 2:52, 2:59, 6:36, 8:154User-Defined Attributes Information - .usd file

12.1© 2011 AVEVA Solutions Ltd Index page vii

Page 814: aveva p&id

AVEVA P&ID 12.1 User Guide

9:17User-Defined Lists of Values . . . . . . . . 2:65Using the Symbol Explorer . . . . . . . . . . 4:10Utilities . . . . . . . . . . . . . . . . . . . . . . . . 8:226

VValidating Pipes . . . . . . . . . . . . . . . . . . 6:36Validation . . . . . . . . . . . . . . 3:4, 6:37, 8:189Validation and Data Transfer . . . . . . . 8:183Validation Files . . . . . . . . . . . . . . . . . . . 6:38Validation Sub-Category . 2:39, 2:84, 2:106, 2:121, 2:130, 2:152Validation using a VPE Workbench Database 6:39Validation using an Access Database . . 6:40Values to Remember from Last Equipment Edit 2:112Values to Remember from Last In-Line Equip-ment Edit . . . . . . . . . . . . . . . . . . . . . . . 2:113Values to Remember from Last Instrument Edit 2:93Values to Remember from Last Nozzle Edit 2:147Values to Remember from Last Pipe Edit 2:71Values to Remember from Last Valve Edit .2:127Valve Label Symbol . . . . . . . . . . . . . . 2:130Valve Labels . . . . . . . . . . . . . . . . . . . . 2:129Valve Port Information - .por file . . . . . . 9:18Valve Settings . . . . . . . . . . . . . . . . . . . 2:126Valve Tag . . . . . . . . . . . . 2:132, 2:172, 8:86Valve Tag Offset from Symbol Location 2:126Valves 2:124, 6:15, 6:17, 6:31, 8:22, 8:24, 8:86, 8:91Valves Configuration Category . . . . . . 2:124

Labels Sub-Category . . . . . . . . . . 2:129Settings Sub-Category . . . . . . . . . 2:125Validation Sub-Category . . . . . . . 2:130

Viewing and Editing Pipe Entity Sequences 8:232Viewing and Exporting to a PDMS Schematic Database . . . . . . . . . . . . . . . . . . . . . . . . 4:26Viewing Upgraded Entities . . . . . . . . . . 5:25VPE Drawing Attributes . . . . . . . . . . . . 2:34VPE Workbench 2:16, 6:39, 7:4, 7:6, 8:189, 8:199, 8:200, 8:201, 8:202, 8:204, 8:205, 9:176VPE Workbench Configuration Category 2:16

XXML File Document Structure . . . . . . . . 9:25XML Model Details . . . . . . . . . . . . . . . . 9:25XML Topology . . . . . . . . . . . . . . . . . . . . 9:26

12.1© 2011 AVEVA Solutions Ltd Index page viii