Automatic Swing Door Operator
DFA 125 G
Manual E
Page 1. Description of Equipment 2 2. Safety Instructions 3 3. Technical Data 4 4. Construction and Function 5 5. Types of Arms 6 6. Lever adapters for stand arms 7 7. Optional lever eyes for sliding and parallel arms 8 8. Installation Plan for Standard Arms 9 9. Dimensional Drawings: Installation 10 / 11 10. Installation and Commissioning 12 - 17 11. Operating instructions 18 - 22 12. Mechanical control elements and indication 23 / 24 13. Configurations 25 - 31 14. Master / Slave Application 32 / 33 15. Interlock mode with 2 single-leaf doors 34 16. Status and fault signals 35 - 37 17. Maintenance instructions 38 18. Control references with new assembly 39 / 40 19. Abbreviations 41 20. Cable Plan 42 / 43 21. Circuit Diagram 44 - 46
agtatec ltd Allmendstraße 24 CH-8320 Fehraltorf Telefon 01 / 954 91 91 Telefax 01 / 954 92 00
Date: 10/2003, TR/CK, Article No. 16.844 Rev. E
1 Description of Equipment The record DFA 125 G is a compact, self-monitoring, microprocessor-controlled
swing door operator. With its many special and additional functions, it is suitable for a very wide application spectrum. Every door movement is controlled in its path: the microprocessor evaluates the current door position, door speed and final position at every instant and precisely calculates the optimum motion. This avoids the necessity for the familiar end-stops, jerky braking actions, creep speeds etc. Depending on the door width, the corresponding spring range must be selected. Safety is also additionally increased by the use of a redundant force limitation.
1.1 Types of Arms, including accessories Depending on the installation situation, the optimal solution can be selected from
three different types of arms (standard, parallel and slide arm). By use of the optional extension pieces, the so-called adaptors, various lintel depths can be compensated.
1.2 Accessories and Special Applications of the DFA 125 G External operating unit BDE With the external BDE, which is available as a flush-mounted or surface-mounted
model, 5 operational modes can be remotely selected. Master / Slave In the Master / Slave operation, 2 DFAs can have sequential control without
additional mechanical components. Not for fire protection! Extended operator casing The installation of additional and sensing devices is possible by use of an
extended operator casing (e.g., integrated fire-alarm control unit 580). Flexible cable connection With the flexible cable connection, the wiring of a DFA mounted on the moving
door leaf can be carried out in an elegant manner. Fire-alarm control unit 580 Through the extension with the 580 fire-alarm control unit and smoke switch, the
DFA becomes the automatic door control system for fire barriers (generally approved for buildings by the German IfBt - Institute for Structural Engineering-Approval No. Z-6.5-1504).
Page 2 10/2003 Rev. E Manual DFA 125 G
2 Safety Instructions The DFA 125 G has been constructed according to the latest state of the art and
the recognised technical safety regulations, including, for example, limiting of forces and speeds. Danger can arise for users, however, if not used as intended.
Installation, maintenance and repairs on the DFA 125 G must only be performed by qualified and authorised personnel.
2.1 Use as intended The DFA 125 G swing door operator is constructed exclusively for normal service
with swing doors in dry rooms and must be installed within or inside buildings. A different application or use extending beyond this purpose is not considered use
for the intended purpose. The manufacturer declines all responsibility for resulting damage; the operator alone shall bear the associated risk.
Use for the intended purpose also includes observation of the operating conditions
specified by the manufacturer, including use and adjustment of the correct type of arms, in addition to regular maintenance and repair.
Unauthorised modifications to the automatic door operator exclude any liability of
the manufacturer for resulting damage.
2.2 General safety and accident prevention regulations
In general no safety devices (sensors) may be dismantled or put out of service.
During the learning cycle (which must only be performed by trained personnel) the safety devices (sensors) are switched off! It must be ensured, therefore, before initiating the learning cycle that no persons or objects are situated in the danger zone of the moving door leaves during the operation in order to avoid injury or damage!
No objects must be placed in the opening zone / path of the swing door to avoid catching and shearing points!
Manual DFA 125 G 10/2003 Rev.E Page 3
3 Technical Data Dimensions: Operator 600 x 104 x 114mm (w x h x d) Operating voltage: 230V∼ Power consumption: Standby 20W, rated power 60W Max. torque: 50 Nm Opening angle: Adjustable from 70° through 110° Time delay: Adjustable from 0 through 20 seconds Opening speed: Adjustable from 3 through 20 seconds Closing speed: Adjustable from 5 through 20 seconds
3.1 Permissible door leaf weights and door widths 450 kg
400 kg
350 kg
300 kg
250 kg
200 kg
150 kg
100 kg
50 kg
0 kg
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
EN 6EN 5
Max
imum
doo
r lea
f wei
ght (
m) [
Kilo
gram
]
Door width (b) [Meter]The EN type corresponds to the spring type
Standard armSliding armParallel arm
The spring types DIN 4 + DIN 5 correspond to the actual spring types EN 5 + EN 6 The curves are calculated using to the following formula:
J = 1/3 × m × b2 Standard arm : J max. 62 kgm2 Key : J = Mass moment of inertia kgm2 Slide arm : J max. 46 kgm2 m = Door leaf weight in kg Parallel arm : J max. 42 kgm2 b = Door leaf width in metres
Page 4 10/2003 Rev. E Manual DFA 125 G
4 Construction and Function
4.1 Construction 1
2 3 4
5
6
7
8
13
9
10 11 12
Key: 1 Closing spring 8 Toggle switch 2 ATE drive unit 9 Standard arm 3 Angular gear 10 Arrow showing sense of rotation 4 NET power supply 11 Allen screw 5 Mains connection terminals 12 Fine-wire fuse 6 STG control unit 13 Malfunction signal 7 STG connection terminals
4.2 Functions The record DFA 125 G is constructed in such a way that it can function as a
normal door closer when without current. It can be easily opened by hand, and closes with the energy stored in the spring, dampened by the motor, which acts as a generator. If the drive is connected to the mains supply, the opening and closing motions are supported by the motor.
The following functions are provided exclusively for the safety of the user: Obstacle detection: If the door strikes an obstacle when opening, it stops
immediately and stores the position of the impact. During the time delay, the drive tries briefly to reach the open position. When the time delay has expired, the door closes, and, when next opened, the door negotiates the impact position very carefully in slow mode. This prevents a second violent impact.
Reversing: If the door strikes an obstacle when closing, it is re-opened
immediately.
Manual DFA 125 G 10/2003 Rev.E Page 5
5 Types of Arms
5.1 Standard arm
max.330
300
Door hinge
60
600
5.2 Slide arm
300
600
192616
Türband
5.3 Parallel arm
Door hinge
max.160
300
600
Page 6 10/2003 Rev. E Manual DFA 125 G
6 Lever adapters for standard arms
'h'
'D'
stan
dard
125.
062.
000
125.
061.
000
125.
063.
000
125.
064.
000
125.
065.
000
2x 1
25.0
64.0
00re
cord
adap
tor 2
reco
rdad
apto
r 3
reco
rdad
apto
r 1
reco
rdad
apto
r 4re
cord
adap
tor 5
reco
rdad
apto
r 6re
cord
adap
tor 7
L =
Leng
th o
f the
scr
ew b
ar (*
adj
usta
ble
leng
th)
D =
32
h =
42L
= 70
le
ver s
ocke
t 42
*
D =
42
h =
52L
= 80
leve
r soc
ket 5
2
D =
52
h =
62L
= 90
le
ver s
ocke
t 42
spac
er 2
0*
D =
72
h =
82L
= 11
0 le
ver s
ocke
t52
spac
er 3
0*
D =
102
h =
112
L =
140
leve
r soc
ket
52sp
acer
60*
D =
132
h =
142
L =
170
leve
r soc
ket 5
2sp
acer
30
spac
er 6
0*
D =
162
h =
172
L =
200
leve
r soc
ket 5
2sp
acer
60
spac
er 6
0
Impo
rtant
: The
nut
on
the
arm
mus
t
b
e ti
ghte
ned!
fully
Manual DFA 125 G 10/2003 Rev.E Page 7
7 Optional lever eyes for sliding and parallel arms
For sliding and parallel arms a standard eye of 13 mm height is included with the delivery. In place of this standard eye can be used one of the two available special eyes: Art.-no. length minus the standard eye effective extension 32.157 30mm - 13mm + 17mm 32.158 48mm - 13mm + 35mm
30mm48mm
Art.-Nr. 32.157 Art.-Nr. 32.158
Page 8 10/2003 Rev. E Manual DFA 125 G
8 Installation Plan for Standard Arms
SG 1
Arm
des
cr.
linte
l dim
ensi
on X
0....
120
125.
060.
000
125.
100.
000
125.
080.
000
100.
...22
021
0....
330
SG 2
SG 3ba
ckpl
ate
with
fixi
ng h
oles
note
pos
ition
of i
nter
med
iate
pie
ce
A
Det
ail A
(top
view
)
50
5010
60
ca. 2
85
5750
275
50
493
114
3044
3044
61
42
- max.13
104
67
300
60
600
X
8
Manual DFA 125 G 10/2003 Rev.E Page 9
9 Dimensional Drawings: Installation
9.1 Drawing 1
2Va
r.2 1
0mm
2Va
r.1 1
0mm
Rah
men
unte
rkan
te
Türo
berk
ante
heel
of d
oor
cent
re o
f doo
r hin
geR
efer
enzk
ante
Var
.1, 3
, 4re
fere
nce
edge
Ref
eren
zkan
te V
ar.1
refe
renc
e ed
ge
low
er e
dge
of fr
ame
uppe
r edg
e of
doo
rR
efer
enzk
ante
Var
.2re
fere
nce
edge
Türb
andm
itte
Türo
berk
ante
Türo
berk
ante
Ref
eren
zkan
te V
ar.2
refe
renc
e ed
ge
Türh
inte
rkan
te
Ref
eren
zkan
te V
ar.4
Ref
eren
zkan
te V
ar.3
refe
renc
e ed
gere
fere
nce
edge
uppe
r edg
e of
doo
rup
per e
dge
of d
oor
(Ban
dsei
te)
(hin
ge s
ide)
Je n
ach
Ges
täng
eart
RIC
HTI
GE
Loch
-Pos
ition
en a
nzei
chne
nm
ark
corre
ct h
ole
posi
tions
in a
ccor
danc
e w
ith a
rm ty
pe
Kopf
mon
tage
(auf
Tür
)in
stal
led
on d
oor
Geg
enba
ndse
iteop
posi
te h
inge
sid
eBa
ndse
itehi
nge
side
Band
seite
hing
e si
deBa
ndse
itehi
nge
side
DIN
link
s dr
ücke
ndD
IN p
ushi
ng to
left
DIN
rech
ts d
rück
end
DIN
pus
hing
to ri
ght
Ges
täng
eart
arm
type
sM
onta
gear
tin
stal
latio
n m
etho
dBa
ndse
itehi
nge
side
Öffn
ungs
art
open
ing
met
hod
Var.
N:
DIN
rech
ts z
iehe
ndD
IN p
ullin
g to
righ
tD
IN re
chts
zie
hend
DIN
pul
ling
to ri
ght
1 2 3 4
Stan
dard
gest
änge
stan
dard
arm
Stan
dard
gest
änge
stan
dard
arm
Gle
itges
täng
esl
ide
arm
Para
llelg
estä
nge
para
llel a
rm
Stur
zmon
tage
inst
alle
d on
lint
el
Stur
zmon
tage
inst
alle
d on
lint
elSt
urzm
onta
gein
stal
led
on li
ntel
1.Sc
hritt
1st s
tep
Var.2
Var.1
Var.4
Var.3
493
50
5750
275
50
443042 30 42
4430 30
4430 30
30
52
59 29 20
201
598
335
50
205
90
2050
20
335
50
Page 10 10/2003 Rev. E Manual DFA 125 G
Dimensional Drawings: Installation
9.2 Drawing 2
2Va
r.6 1
0mm
2Va
r.5 1
0mm
Rah
men
unte
rkan
te
Türo
berk
ante
heel
of d
oor
cent
re o
f doo
r hin
geR
efer
enzk
ante
Var
.5, 7
, 8re
fere
nce
edge
Ref
eren
zkan
te V
ar.5
refe
renc
e ed
ge
low
er e
dge
of fr
ame
uppe
r edg
e of
doo
rR
efer
enzk
ante
Var
.6re
fere
nce
edge
Türb
andm
itte
Türo
berk
ante
Türo
berk
ante
Ref
eren
zkan
te V
ar.6
refe
renc
e ed
ge
Türh
inte
rkan
te
Ref
eren
zkan
te V
ar.8
Ref
eren
zkan
te V
ar.7
refe
renc
e ed
gere
fere
nce
edge
uppe
r edg
e of
doo
rup
per e
dge
of d
oor
(Ban
dsei
te)
(hin
ge s
ide)
Je n
ach
Ges
täng
eart
RIC
HTI
GE
Loch
-Pos
ition
en a
nzei
chne
nm
ark
corre
ct h
ole
posi
tions
in a
ccor
danc
e w
ith a
rm ty
pe
Kopf
mon
tage
(auf
Tür
)in
stal
led
on d
oor
Geg
enba
ndse
iteop
posi
te h
inge
sid
eBa
ndse
itehi
nge
side
Band
seite
hing
e si
deBa
ndse
itehi
nge
side
DIN
rech
ts d
rück
end
DIN
pus
hing
to ri
ght
DIN
link
s dr
ücke
ndD
IN p
ushi
ng to
left
Ges
täng
eart
arm
type
sM
onta
gear
tin
stal
ling
met
hod
Band
seite
hing
e si
deÖ
ffnun
gsar
top
enin
g m
etho
dVa
r.N
:
DIN
link
s zi
ehen
dD
IN p
ullin
g to
left
DIN
link
s zi
ehen
dD
IN p
ullin
g to
left
5 6 7 8
Stan
dard
gest
änge
stan
dard
arm
Stan
dard
gest
änge
stan
dard
arm
Gle
itges
täng
esl
ide
arm
Para
llelg
estä
nge
para
llel a
rm
Stur
zmon
tage
inst
alle
d on
lint
el
Stur
zmon
tage
inst
alle
d on
lint
elSt
urzm
onta
gein
stal
led
on li
ntel
1.Sc
hritt
1.St
ep
Var.6
Var.5
Var.8
Var.7
493
50
5750
275
50
443042 30 42
4430 30
4430 30
30
52
59 29 20
201
598
335
50
205
90
2050
20
335
50
Manual DFA 125 G 10/2003 Rev.E Page 11
page 12 10/2003 Rev. E Manual DFA 125 G
10 Installation and Commissioning 10.1 Checking the Installation Site
• Does the door leaf move easily over its entire swing range?
• Have all damping devices been removed (not simply reset)?
• Is the base on which the DFA 125 G is to be mounted sufficiently stable
• If a electrical lock is present. Does the door leaf drop cleanly into the lock?
10.2 Positioning the DFA and arm
• Depending on the type of installation, mounting plate and arm, mark the corresponding drilling positions on the template
• Fix the template to the corresponding position
• Drill the holes
10.3 Mechanical installation of the DFA
• Fix the mounting plate, place the cables in position and mount any flex-connections
• Install the DFA ⇒ Note sense of rotation (arrow on gear cover)
• Prepare arm (preliminary assembly corresponding to final position, square, see
installation plan, Detail A), screw arm into its correct position on the DFA (pre-tension). Screw arm securely to door leaf. Set the arm at 90° to the door leaf.
10.4 Check of mechanical functions
• Is the arm at right angles to the door leaf?
• When moved by hand, does the door leaf move easily over its full swing range?
• Does the DFA function satisfactorily as a mechanical door closer?
Installation and Commissioning 10.5 Connecting the sensors, electrical door openers
• Connect radar, opto-sensor strips and electric door openers (electrical door openers must have suppressor diode) with power switched off.
10.6 Preparation
Read safety instructions (chapter 2) and observe!
1. Interrupt power supply with main switch or power plug
2. The power supply cable must be fitted with the ferrit core (article no. 16.777) and connected to the power supply
3. Check wiring according to general schematic diagram AS.E.126.101
10.7 Checking settings 1. Position jumpers for the required function according to chapter 11, operating
instructions 2. Check external jumpers for auxiliary units not connected, such as
EMERGENCY STOP, SIS, SIO
Erdver-bindungs-schraube
J4
NET
ATE
LD4Geschl.Erde
LD3+35V+24V
LD2
CP
U2
CP
U1
SlaveMaster
J9J6
BDE-Seitenteil
Leitungsab-schluss CAN
J10
J1
121110
98
76
543
21
NOT-AUSNOT-AUS
+24VSSKGND
SIS+24V
SIOGNDAKAAKI
+24V
J3
2827
2625
GND+24VCANLCANH
J2
GNDVRRVRRVRR+24VVAK
181716
1514
13
agtatec agCH-8320 Fehraltorf
Nr. 126.600.000
STG DFA 125 G
GeberJ5 Kontroll-
LED
LD1
S1
J8
Manual DFA 125 G 10/2003 Rev. E page 13
Installation and Commissioning
10.8 Switching on power supply and calibration run 1. Switch on power supply
2. A calibration run is performed automatically when switching on the supply voltage for the first time or following a hardware reset (see status messages) the door is braking for test during calibration the weight of door leaves
3. Check the configuration of the arm in the 1. configuration level !! 4. Start the calibration run with the push button S1 on the STG DFA 125 G, after 5
seconds waiting period the calibration run will start (without the calibration run the door will not work)
5. The door parameters are determined during the first opening cycle
The door must not be obstructed in any way during the calibration run
In the event of uncontrolled door motion, interrupt the power supply immediately.
10.9 Checking LED’s on the STG Check LED’s 1 - 7 according to the table in chapter 11
10.10 Checking BDE functions and actuating devices BDE position (continuously open) 1. Door must open and remain open 2. Check movement characteristics 3. Door cannot be moved by hand when open
page 14 10/2003 Rev. E Manual DFA 125 G
Installation and Commissioning BDE position (locked) 1. Door must close 2. Check movement characteristics 3. Check locking if present (see chapter 15 for status message for wrong
behaviour) 4. Pressing initiates an SSK opening 5. SSK must release (if present) 6. AKI and AKA must not operate BDE position (one-way traffic) 1. AKI and SSK must operate 2. AKA must not be triggered when door is closed
Manual DFA 125 G 10/2003 Rev. E page 15
Installation and Commissioning
10.11 Programming door speeds and hold-open times These functions are described in chapter 11, “operating instructions”
10.12 Configuration of specific customer settings The possibilities are described in chapter 13, “configurations” All modifications must be entered on the configuration sheet (situated in the drive)
10.13 Checking safety 1. BDE position (automatic) 2. Open door (e.g. with AKI) 3. Operate a safety device while closing. Door must re-open. 4. The same check must be performed if another safety device is present
10.14 Checking automatic reverse 1. Obstruct door while closing ➔ door must reverse. When the door next closes it
moves at creep speed past the obstruction point. 2. Obstruct the door while opening ➔ door stops for hold-open time and closes.
When the door next opens it moves at creep speed past the obstruction point.
10.15 Touch control • See about the configuration in chapter 13. By pressing
lightly on the door, a door-opening will be initiated. 10.16 Checking the DFA’s functions • Checking of all DFA functions • Tighten the arm screw
page 16 10/2003 Rev. E Manual DFA 125 G
Installation and Commissioning 10.17 Hand over to client • Instruct the client • Hand over the operating manual • Reset demonstration :
With mechanical control unit : If the button is pressed until the status signal LED
will light on a new start of the control is performed. With electronic control unit : If the key is pressed until all LED’s fully lit a
new start of the control is performed
Manual DFA 125 G 10/2003 Rev. E page 17
page 18 10/2003 Rev. E Manual DFA 125 G
11 Operating instructions 11.1 Controls on STG DFA 125 G
General: The STG DFA 125 G operates with active HIGH level, i.e. a +24 V level must be applied
to activate a function. Safety inputs are activated during interruptions. The signal ground (0 V) is connected to protective earth. This connection can be removed for test purposes with the earthing screw at bottom left.
Jumpers: J9: Master / Slave
jumper at position 1-2 for Master (factory setting) jumper at position 2-3 for Slave
J10: For CAN line termination LED’s : LED 1: (green) Large control LED for push-button operation
LED 2/1: (red) Alarm CPU 1
Lights when alarm present CPU 1
LED 2/2: (red) Alarm CPU 2 Lights when alarm present CPU 2
LED 3/1: (green) +24V: lights when mains or battery voltage present
Caution: In the event of a power failure processor reset only takes place 1 sec. after this LED extinguishes.
LED 3/2: (green) +35 V: off for power failure
LED 4/1: (red) Ground: must light when earthing screw removed (bottom left).
Otherwise an earth connection is present
LED 4/2: (red) This LED is out of function !
Manual DFA 125 G 10/2003 Rev. E page 19
Operating instructions
Key: This multifunction key has several functions.
The selection of function is made with the aid of the neighbouring control LED according to the following table:
Release key while: Function: 1st light pulse on LED 7 AKI 2nd light pulse on LED 7 ** ** Configuration mode 1st level Slave on 3rd light pulse on LED 7 Learn door parameters 4th light pulse on LED 7 Configuration mode on 5th light pulse on LED 7 6th light pulse on LED 7 * * Initial spring tension 8th light pulse on LED 7 Factory setting of programming and
configurations Press key approx. 13 seconds Hardware reset (new control start)
* Initial spring tension must be done without connection to the door leaf ! (Before initiating this function, the arms must be dismounted, that is, the door leaf may
not be connected to the drive!)
If a control unit is changed, this function must be initiated ! ** With this function the same configurations (configuration level 1) can be made on page
25 in this manual are described for the slave independently of the master. Possible only if in the configuration level 3 “single leaf interlock control” is configured !
Operating instructions
page 20 10/2003 Rev. E Manual DFA 125 G
2
1
4
5
3
6
11.2 Functions of electronic BDE-E General: The electronic control unit BDE-E is a convenient input and output unit. It contains
several virtual control levels. The normal level (1st level) contains the standard modes of operation.
All LED’s light in sequence during the first few seconds after switching on the
power supply (run light) and the last operating mode is then displayed. 1st level (operating modes) Key functions: One-way operation
Manual operation
Automatic mode
Continuously open Locked
Programming
Programming increment down
Programming increment up The LED is off in this level. If the key is pressed again in the „locked“ status, an SSK opening takes place If the key is pressed until all LED’s fully lit a new start of the control is
performed. The programmed data remain stored 2nd level (control lock) Entry to this level with key sequence: The LED lights. The BDE is blocked. Exit from this level with key sequence: This releases operation again.
Operating instructions 3rd level (programming level) SINGLE DRIVE + MASTER Entry to this level with key sequence: The LED flashes slowly Selection of following menus by key operation The value is displayed while the key remains pressed The value display takes place proportionately in max. 40 increments Divided in 5 LED’s from left to right, with each LED divided into 8 increments. The
range from 0% to 100% is thereby covered.
Example: door hold-open time 6s
LED fully lit (corresponding to 1 time 8 increments)
LED has an on/off ratio of ½ (corresponding to 4 increments)
LED , , remains off
Therefore total 12 increments = 6s
Menu functions:
Programming function Range Step width Standard values
Closing speed 5 – 20s 0,5s 9s
Opening angle 70° - 110° 1° 100°
Door hold-open time 0 – 20s 0,5s 2s
Opening speed 3 – 20s 0,5s 3s
Automatic reverse 1 - 40 1 20
Setting:
Following menu selection (the LED lights for the menu selected) the value can be changed by pressing the or keys several times.
The current value is displayed while these keys are pressed.
The setting returns to the lowest value at the upper range limit and vice-versa. Simultaneous operation of the and keys resets the values to the standard values.
The key must be pressed briefly to leave the programming level. It is also left automatically if no key is pressed for 3 minutes (timeout).
Manual DFA 125 G 10/2003 Rev. E page 21
Operating instructions
4th level (programming level) SLAVE
Entry to the level can only be made by the control unit or testbox, which will be connected to the STG 125 from the Master- drive !
Entry to programming level with key sequence: LED flashes quickly. Selection of following menus by pressing relevant key. The value is displayed while the key remains pressed.
Menu functions:
Programming function Range Step width Standard values
Closing speed 5 – 20s 0,5s 9s
Opening angle 70° - 110° 1° 100°
Door hold-open time 0 – 20s 0,5s 2s
Opening speed 3 – 20s 0,5s 3s
Automatic reverse 1 - 40 1 20
Setting:
Following menu selection (the LED lights for the menu selected) the value can be changed by pressing the or keys several times. The current value is displayed while these keys are pressed. The setting returns to the lowest value at the upper range limit and vice-versa. Simultaneous operation of the and keys resets the values to the standard values. The key must be pressed briefly to leave the programming level. It is also left automatically if no key is pressed for 3 minutes (timeout).
The changed data’s (opening angle / automatic reverse) get stored when you exit the 4th programming level !
page 22 10/2003 Rev. E Manual DFA 125 G
12 Mech. control elements and indication
1 2 3
1 Mech. BDE 3 Positions (control toggle switch) 2 Reset button 3 Status signal
Mechanical BDE (control toggle switch) The following operational modes can be set up with the 3-position toggle switch on the side cover: Manual operation I : In this operational mode, the DFA functions as a normal door-closer. It can easily be opened by hand, and closes again automatically. The connected actuating devices are ignored. Automatic o : The door opens and closes automatically, either by the activation of a actuating element, or by nudging the door by switching on the touch control. Continuously open II : The door opens and then remains in the open position. If an obstacle is encountered while opening, the DFA will attempt to bring the door into the set open position five more times, within the next few seconds. If the obstacle is still present, the current position will be accepted as the continuously-open position.
Manual DFA 125 G 10/2003 Rev. E page 23
page 24 10/2003 Rev. E Manual DFA 125 G
Mech. control elements and indication
The mechanical BDE is always connected and activ on a DFA 125 G. Is there additional one BDE-E connected will the operating mode be set by a definition of a priority structur from the BDE with the highest priority.
The priority and the code shown in the following table apply to the operating mode, whereby BDE2 (S2) and BDE1 (S1) represent the two STG input terminals:
(L = interruption or 0V, H = +24V)
Mechanical BDE (toggle switch)
Electronic BDE-E
BDE2 (S2) BDE1 (S1) Function Priority (1=highest)
locked 1 one-way traffic 2 L H Continuously open 3 H L manual control 4 L L automatic 5
The BDE indicates the current operating mode.
If an operating mode is set on the BDE-E, which has no current priority, the status message 62 is displayed.
Reset button If the button is pressed until the status signal LED will light on, a new start of the control is performed (software reset). Status signal Remains off if no fault present.
Will blink if a fault is present (see status and fault signals / chapter 15).
Does fully lit during a reset.
13 Configurations
Configurations of the DFA 125 G can only be made with the electronic BDE-E or the optional Servicebox. If a mechanical BDE-M is connected, a BDE-E or Testbox must be connected briefly for the configuration. All configurations must be marked as follows in the relevant box: ✘ = corresponding control LED lights - = corresponding control LED does not light Please always leave the configuration review sheet in the drive even when the STG is replaced!
Conf. Level
LED 1 LED 2 LED 3 LED 4 LED 5 Def. Modification Def. Modification Def. Modification Def. Modification Def. Modification
1 - - - - -
2 - - - - -
3 - - - - ✘
4 - - - - -
5 - - - - -
1st configuration level Entry to the configuration levels can only be made with the push-button on the STG. The button must be pressed until the 4th light pulse on the large control LED. The BDE-E is then in the first configuration level. The LED on the BDE-E flashes in mode 1 as acknowledgement, i.e. the LED lights periodically for approx. 0.15 s with an interval of approx. 2 s (light pattern ).
The change between configuration levels is made by pressing the or key. Exit from the configuration levels is made by pressing the key briefly or if no operation takes place for 3 minutes (timeout).
LED No.: Function:
Factory setting: (Default)
Default LED:
1 + 2 Standard arm Factory setting off / off
1 + 2 Slide arm not activated on / off
1 + 2 Parallel arm not activated off / on
1 + 2 not activated on / on
3 External mech. BDE (from V1.1) ** not activated off
4 Touch control not activated off
5 „Permanent locked“ * not activated off
Manual DFA 125 G 10/2003 Rev. E page 25
page 26 10/2003 Rev. E Manual DFA 125 G
Configurations * If no BDE-E is connected and an electrical lock is controlled by the DFA 125 G, you always
must configure “Permanent locked”. ** The Inputs (BDE1, BDE2) will be interpreted in a different manner. The use of an adapting
cable (126.107.000) between control unit STG and the toggle switch is imperative. This adapter is equipped with clamps which allows the connection of a mechanical BDE. The clamp numbers 5/6/7 correspond to the mechanical BDE of the STA 16.
Adapting cable 126.107.000 :
Terminal marking on cables
Clamps on STG DFA 125 G
5 + 24 V 6 BDE 2 7 BDE 1
In the case of use of the adapting cable the RESET button and the ALARM display on the side cover remain in function! If the Inputs of the mechanical BDE are activated, then the toggle switch on the side plate is out of function ! Function chart:
Mechanical BDE (toggle switch)
BDE2 / Clamp 6 BDE1 / Clamp 7 Function
L L locked L H continuously open H H manual control H L automatic
( L = interruption or 0V, H = +24V )
External toggle switch
BDE2 / Clamp 6 BDE1 / Clamp 7 Funktion
L H continuously open H H manual control H L automatic
( L = interruption or 0V, H = +24V )
Configurations
Connection of a time switch for "locked" (SUR-V)
* contact closed = mode of operation in accordance with attitude on the operation
Manual DFA 125 G 10/2003 Rev. E page 27
switch contact open = mode of operation “locked”
STG DFA 125 G
J7/5 (+24V)
J7/6 (BDE2)
contact of time switch *
Configurations
2nd configuration level The change from 1st to 2nd configuration level is made with the key. The. LED flashes in mode 2 as acknowledgement on the BDE-E, i.e. the LED lights periodically twice with an interval of approx. 2 s (light pattern ).
The change between configuration levels is made by pressing the or key. Exit from the configuration levels is made by pressing the key briefly or if no operation takes place for 3 minutes (timeout).
LED No.: Function:
Factory setting: (Default)
Default LED:
1 Manual operation only during closing cycle *
not activated off
2 Manual operation when locked not activated off
3 Manual operation with support during closing cycle ** not activated off
4 Manual operation with relays *** not activated off
5 Manual operation with sensors active **** not activated off
* After the release of a opening cycle the door is switched during the closing procedure (until
the door is completely closed) to "manual operation" ** The last 10° before „closed“ - position will be supported by motor *** Manual operation without motor support to „open - direction“ **** Manual operation in combination with activation of the sensors by remote release (remote
control) For a faultless function “manual operation with relais” or “manual operation with
sensors active“ the BDE-E or the toggle switch must be on position in addition to the configuration !
Configuration “manual operation” in combination with activation of the sensors by remote control for handicapped people :
For not handicapped people the door works in manual operation. Handicapped people are enabled to open the door automatically by remote control.
Configuration: - put the BDE-E or toggle switch to position “manual operation” - activate “ Manual operation with sensors active” (2nd config.level /LED5) - Do not activate “Manual operation with support during closing cycle”
page 28 10/2003 Rev. E Manual DFA 125 G
Configurations
3rd configuration level The change from 2nd to 3rd configuration level is made with the key. The LED flashes in mode 3 as acknowledgement on the BDE-E, i.e. the LED lights periodically three times with an interval of approx. 2 s (light pattern
).
The change between configuration levels is made by pressing the or key. Exit from the configuration levels is made by pressing the key briefly or if no operation takes place for 3 minutes (timeout).
LED No.: Function:
Factory setting: (Default)
Default LED:
1 Master by (Master and Slave) * not activated off
2 Single leaf interlock control ** not activated off
3 Slave will be set at 0° to activate the mode “closing of the master” not activated off
4 Fire alarm box (from V1.1) **** not activated off
5 Spring type EN 5 *** activated on
* Will get automatically identified and stored on a Master / Slave – drive ** From software version V1.3 on (this function is described in chapter 15 on page 33) *** Only monitoring, can not be done by configuration **** Special operation on use of the DFA 125 G in connection with a fire alarm box.
Manual DFA 125 G 10/2003 Rev. E page 29
Configurations
4th configuration level The change from 3rd to 4th configuration level is made with the key. The LED flashes in mode 4 as acknowledgement on the BDE-E, i.e. the LED lights periodically four times with an interval of approx. 2 s (light pattern
).
The change between configuration levels is made by pressing the or key. Exit from the configuration levels is made by pressing the key briefly or if no operation takes place for 3 minutes (timeout).
LED No.: Function:
Factory setting: (Default)
Default LED:
1 Master / Slave control (from V1.1) * not activated off
2 Master / Slave “simultaneous opening” **
not activated off
3 Electrical door lock opens with EMERGENCY STOP (escape route) ***
not activated off
4 not activated off
5 not activated off
* The master/slave control is only efficacious on master/slave installations. Actuating AKA: causes the opening of only the master door leaf Actuating of the causes the normal opening of master and slave door leaves remaining actuators:
** Only for operators without lap over of the door wings, there will be no opening - and closing follower control
*** On factory setting (standard), the door lock will not open during
EMERGENCY STOP = case of fire
page 30 10/2003 Rev. E Manual DFA 125 G
Configurations
5th configuration level The change from 4th to 5th configuration level is made with the key. The LED flashes in mode 5 as acknowledgement on the BDE-E, i.e. the LED lights periodically five times with an interval of approx. 2 s (light pattern
).
The change between configuration levels is made by pressing the or key. Exit from the configuration levels is made by pressing the key briefly or if no operation takes place for 3 minutes (timeout).
If you take exit from the configuration level 5, there will be a restart.
LED No. 1
LED No. 2
LED No. 3
LED No. 4
LED No. 5
Function:
Factory setting: (Default)
Standard:LED: 1=on
0 0 0 0 0 Basic-DFA Factory setting 0 0 0 0 0
0 0 0 0 1 Airport Brussels not activated
0 0 0 1 0 reserve not activated
0 0 0 1 1 reserve not activated
0 0 1 0 0 reserve not activated
0 0 1 0 1 reserve not activated
0 0 1 1 0 reserve not activated
0 0 1 1 1 reserve not activated
0 1 0 0 0 reserve not activated
0 1 0 0 1 reserve not activated
0 1 0 1 0 reserve not activated
0 1 0 1 1 reserve not activated
Manual DFA 125 G 10/2003 Rev. E page 31
14 Master / Slave Application 14.1 Use The master / slave control allows the DFA 125 G to perform sequential controls
without the need for external supplementary devices. This master / slave control is used with double-leaf doors, which require specific opening and closing sequences. A particular feature of the master / slave control of the „record“ DFA 125 G is that all the safety functions recognised by the DFA 125 G also function with double-leaf doors. This applies in particular to reversing, obstacle recognition, and slow mode. The two controls continuously communicate with one another via the intelligent interface between the master and the slave operator, so that any obstacle within the swing range of one door is always recognised by both drives.
MasterSlave(stand leaf) (moving leaf)
14.2 Functions The functions of the master and the slave operators correspond basically to those
of the standard DFA. The following points are specifically mentioned: Obstacle recognition: If one of the doors is obstructed during opening, only the
obstructed door stops. In addition, during the next opening action, only this door will open in Slow-mode. The obstacle recognition for the two door leaves therefore functions independently for each door.
Reversing: Reversing, on the other hand, affects both door leaves, that is, both
doors reverse after one of them hits an obstacle. This avoids an obstacle in the swing range being hit by both door leaves.
BDE in Master / Slave installations: The operation of a master / slave installa-
tion can only take place from the toggle switch of the master operator. All opera-tional modes are identical with those of a standard DFA. The switch position of the master affects both the master and the slave drive, that is, the switch position of the slave drive is ignored. Emergency switch: If a Master/Slave installation needs to have a emergency switch, there is to use a 2-pole emergency switch.
(see about that in the Master/Slave wiring diagram in this manual)
page 32 10/2003 Rev. E Manual DFA 125 G
Manual DFA 125 G 10/2003 Rev. E page 33
Master / Slave Application 14.3 Commissioning Note that, for master / slave installations, the commissioning differs as follows
from that of the standard DFA: • The operators of a master / slave installation must be connected together via
the communication line and the CAN-isolator (see circuit diagram master / slave in this manual).
• By the operators of a master / slave installation must be set the CAN bus
terminating resistance of line J10 (see circuit diagram master / slave in this manual).
• The actuation devices must be connected to the master. AKI, AKA and SSK will
be ignored by the slave. • Safety actuation devices (SIO, SIS) which are mounted on both door leaves
must be connected to the corresponding operator, that is, SIS on the slave leaf must be connected to the slave drive.
• Using the jumper J9 on the STG DFA 125 G , one operator is switched as
master, and the other as slave. The operator of the moving door leaf must always be selected as the master (see circuit diagram master / slave in this manual).
• The current feed to both operators must either be switched on simultaneously,
or the slave must be switched on first. • The learning cycle is carried out individually for each operator. During the
learning cycle of the slave, the master also opens, so that the slave will not be obstructed.
• The opening and closing speeds are the same for both operators. The value is
transmitted from the master to the slave. In the same way, the time delay is also dictated by the master. Therefore, if these values are to be modified, they must be set and acknowledged at the master operator; the slave takes the values over immediately.
• The opening angle and automatic reverse, can be set separately at each
operator. See about the setting in programming level 3 + 4. • If one of the operators should fail, it is recommended that the second operator
too should be disconnected from the power feed. Both operators can then be restarted as normal, as described above.
• Special function for mechanical sequential control:
For the use of an additional mechanical sequential control the closing angle of the slave will be set at 0° to activate the mode "closing of the master". This function can be activated in the 3rd configuration level.
15 Interlock mode with 2 single-leaf doors
15.1 Function From software version 1.3 on, the DFA 125 G enables two single-leaf doors to be
operated in a interlock mode. This means that one door can be opened with AKI and SSK only if the other door is closed. An ‚OPEN‘ command to the closed door is stored. Priority: If in the interlock mode AKI or SSK are operated simultaneously at master and slave, the master opens first. All safety functions known from DFA are also activated in this mode.
15.2 Putting into operation the interlock mode
• Via Jumper J9, one operator is set to master and the other to slave.
• The two DFA operators must be connected via the communication line CAN-Isolator Art. No. 126.620.000 (see circuit diagram AS.D. 126 102A in this manual).
• The master door requires an electronic operating unit BDE-E Art. No. 126.800.000. Connection is made according to circuit diagram AS.D. 126 102A in this manual.
• Configuration on BDE-E ‚interlock mode‘ Configuration Level 3, LED No. 2 . • On control device of master:
replug Jumper 10 to ‚with BDE‘ (see circuit diagram AS.D. 126 102A in this manual).
15.3 Functions of the electronic BDE-E in interlock mode
Key Function interlock mode
One door can be opened with AKI and SSK provided that the other door is closed.
No interlock mode. Both doors on manual operation.
No interlock mode. Both doors function as with 2 individual operators with AKI and AKA.
No interlock mode. Both operators on permanently open.
interlock mode Same function as one-way, but opening only possible with SSK. Relay contact for electric door-opener is activated.
page 34 10/2003 Rev. E Manual DFA 125 G
16 Status and fault signals Status level (display only) In the event of irregularity change is made automatically from the operating mode
level to the status level. Change is then made approx. every 5 seconds between status and operating mode level. No status display is given in the remaining levels. Characteristic of the status level are 2 or more rapidly flashing LED`s of total 6 LED`s. This permits a maximum of 58 different status numbers to be output. A status with „W“ is a warning, which is not followed by switching of the fault output relay. The status is deleted in various ways according to the detailed description (resetting), as you can see in the manual.
LEDs on BDE-E:
1 2 3 4 5 6 LED No:
Remarks:
x x 03 AKI - sensor active longer than 60s x x 05 AKA - sensor active longer than 60s x x 06 Unlocking error x x x x 23 Control unit SLAVE defective x x x 25 MASTER / SLAVE connection
interrupted x x x x x 31 EMERGENCY STOP button operated x x x 37 Wrong motor current x x x 38 Excess temperature motor x x x x 39 Overload on +24 V supply x x x 41 Motor - thermal sensor defective x x x x 43 Incremental generator defective x x x x 45 Motor current time product too high x x x x 46 Control unit defective x x x x x 47 SIO – sensor active longer than 60 s x x x 50 Control unit CPU2 is faulty x x x 52 No valid drive parameter x x x x 53 Interruption Motor x x x x 54 W Calibration run x x x x x 59 SIS - sensor active longer than 60 s x x x x 60 Parameter memory defective
(EEPROM) x x x x x 61 SSK - sensor active longer than 60 s x x x x x 62 W BDE has no priority • A status number with a "W" is a warning !!
Manual DFA 125 G 10/2003 Rev. E page 35
Status and fault signals
Detail description of status indications General: A status can usually be deleted by pressing the key for 5 s (= reset). This produces a
new start in the control unit. If, however, the cause of the fault has not been eliminated, the status message will appear again if the fault occurs again.
The causes of faults are listed with decreasing probability in the following list. The fault
may be suspected with the least probability in the STG at the end of the faults. Status 03: AKI sensor active longer than 60 s
Automatic resetting, provided in order, or by service fitter Status 05: AKA sensor active longer than 60 s
Automatic resetting, provided in order, or by service fitter Status 06: Unlocking fault
Possibly lock jammed Reset by service fitter
Status 23: Control unit SLAVE defective Reset by service fitter
Status 25: MASTER / SLAVE connection interrupted
Reset by service fitter Status 31: EMERGENCY STOP operated
Reset by resetting EMERGENCY STOP key Status 37: Defective motor current
STG or ATE defective Reset by service fitter
Status 38: Excess temperature motor
Manual control effective Door leaves possibly too heavy or there is too much friction Reset by motor cooling or by service fitter
Status 39: Overload on +24 V supply
Possibly too many external units connected Reset by service fitter
Status 41: Motor - thermal sensor defective
Motor possibly not connected Sensor in motor possibly defective or cable broken in sensor lead Reset by service fitter
page 36 10/2003 Rev. E Manual DFA 125 G
Manual DFA 125 G 10/2003 Rev. E page 37
Status and fault signals Status 43: Incremental generator defective
Generator cable possibly not connected or cable broken in lead Motor possibly blocked Reset by service fitter
Status 45: Motor current time product too high
Possibly too much traffic with door leaves too heavy Hold-open time extended to approx. 20 s Automatic resetting by cooling
Status 46: Control unit defective
Includes the following individual faults: EPROM, RAM, Watchdog, Imax, ImaxT, difference on SHE-EXT Reset by service fitter
Status 47: SIO sensor active longer than 60 s
Automatic resetting, if in order, or by service fitter Status 50: Control unit CPU2 is faulty
Reset by service fitter
Status 52: No valid drive parameter Status 53: Interruption motor
Reset by service fitter Status 54: Calibration run
Wait until door is closed Automatic resetting after completion of 1 opening cycle
Status 59: SIS sensor active longer than 60 s
Automatic resetting, if in order, or by service fitter Status 60: Parameter memory defective (EEPROM)
Change control unit Reset by service fitter
Status 61: SSK sensor active longer than 60 s
Automatic resetting, if in order, or by service fitter Status 62: BDE has no priority, since higher-level signal present.
Cancel higher-order mode of operation
page 38 10/2003 Rev. E Manual DFA 125 G
17 Maintenance Instructions The following points must be checked: Base fixing Is the DFA 125 G securely fixed to the backing construction ? Chassis Is the attachment still normal ? Hinge plate Can the door leaf be moved still low-friction ? Is the
attachment still normal ? Arm Has the fixing screw of the arm been firmly tightened ? Function Does the movement of the door give reason for
dissatisfaction ? Cabling Are all cables connected and the clamping screws tightened ?
Are the connections to the motor ok ? Calibration run Release a new calibration run. Control unit BDE Check the function of all modes of operation. Actuating devices Function test of radar, push button, pull-switch etc. Safety elements Function test of safety cells on door leafs (SIO/SIS). Safety functions Examine the external connections ( fire alarm / EMERGENCY
STOP / SSK). Electrical door
lock Function test of electrical door lock and latch plate switching contact.
Casing Are the casing and the side cover plates cleanly installed ? Master / Slave-
Installation Mechanical control at both operators.
Control of sequence of functions. Examine from closing subsequent linkage (if available).
Manual DFA 125 G 10/2003 Rev. E page 39
18 Control references with new assembly The following points must be checked: Base fixing Is the DFA 125 G securely fixed to the backing construction ? Chassis Is the attachment still normal ? Hinge plate Can the door leaf be moved still low-friction ? Is the
attachment still normal ? Door wing Do the leaf weight and the leaf width correspond to the
defaults in accordance with diagram in this manual ? Arm Has the fixing screw of the arm been firmly tightened ? Function Does the movement of the door give reason for
dissatisfaction ? Main connection Is the mains connection cable led by the provided
ferrite core ? Cabling Are all cables connected and the clamping screws tightened ?
Are the connections to the motor ok ? BDE connection Was the prescribed cable used and installed regulation in
accordance with ? CAN isolator Is the CAN isolator assigned in the connection line between
Master and Slave operator ?
Configuration Was the configuration of the operator done in accordance with
default ? Was the filled out configuration sheet bonded into the casing ? Calibration run Was the calibration run done. Control unit BDE Check the function of all modes of operation. Actuating devices Adjusting + function test of radar, push button, pull-switch etc. Safety elements Adjusting + function test of safety cells on door leafs
(SIO/SIS). Safety functions Examine the external connections ( fire alarm / EMERGENCY
STOP / SSK).
page 40 10/2003 Rev. E Manual DFA 125 G
Control references with new assembly The following points must be checked: Electrical door
lock Does the electrical door lock have enough free motion ?
Is the diode over the connection of the electrical door lock
attached? Function test of electrical door lock and latch plate switching
contact. Master / Slave-
Installation Mechanical control at both operators.
Control of sequence of functions. Examine from closing subsequent linkage (if available). Casing Are the casing and the side cover plates cleanly installed ? Logo Is the record logo correctly attached ?
Manual DFA 125 G 10/2003 Rev. E page 41
19 Abbreviations A ABS Absolute pulse generator AKA Actuating-contact „outside“ AKG Actuating-contact „common“ AKI Actuating-contact „inside“ AS Master wiring diagram / Circuit diagram ASK Terminals inside header ATE Driving-unit B BDE-E Control-unit electronic BDE-M Control unit mechanical BKL Control-unit-LED BKS Control-unit-switch C CAN-H Serial interface CAN.L Serial interface CPU microprocessor D DFA Automatic swing door operator E EPROM program storage ES Electric scheme F FV Manufacturing regulations G GTR Gearing H HS Mains switch 2-pole I IKG Incremental generator L LED Luminous diode LS Cable plan
M MOT Motor MP Mounting principle plan N NA Emergency stop button NS Main power switch NSA Mains failure R RAD-A Radar (scan) „outside“ RAD-I Radar (scan) „inside“ RSK Locking contact S SI Fuse SIO Safety open SIS Safety close SSK Key-operated contact STG Control-unit STG STP Control print T TOE Door locking device TOW Width of door-opening TOZ Length of time that door is held open U µP Microprocessor V VL Wiring list VMA Instructions for wiring and mounting VRK Locking contact VRR Locking-device
Nam
eM
asss
tab
%Fr
eige
gebe
n
Erst
ellt
Dat
um
agta
tec
agC
H-8
320
Fehr
alto
rf
Leitu
ngss
chem
aSc
hém
a de
câb
lage
Cab
le la
yout
Sche
ma
dei f
iliA
ttenz
ione
!D
uran
te la
not
te l’
auto
mat
ism
o no
n de
ve e
sser
edi
sins
erito
dal
la re
te d
i ten
sion
e.
Wic
htig
er H
inw
eis!
Die
Anl
age
soll
wäh
rend
der
Nac
ht N
IE d
urch
eine
n G
ener
alsc
halte
r vom
Net
z ge
trenn
t wer
den.
Avis
impo
rtant
!N
e pa
s dé
brac
her l
e sy
stèm
e du
rése
au p
enda
ntla
nui
t.
Impo
rtant
not
ice!
The
inst
alla
tion
is n
ot in
tend
ed to
be
disc
onne
cted
from
the
mai
ns a
t nig
ht.
Forn
itura
eff.
da
voi s
econ
do d
ispo
sizi
oni u
ffici
ali
Lief
erun
g ba
usei
ts g
emäs
s be
hörd
liche
r Vor
schr
iftA
four
nier
par
aille
urs
selo
n sp
écifi
catio
n of
ficie
lleTo
be
furn
ishe
d by
oth
ers
acco
rdin
g to
offi
cial
regu
latio
n
* Baus
telle
Cha
ntie
rSi
teC
antie
re
Auftr
ags-
/Com
man
de-/
Ord
er-/C
omm
issi
one
Nr/N
o:
Aen
deru
ng:
A 0
1/53
km
21.
05.0
1
LS.1
2610
1A
km km
21.0
2.01
21.0
5.01
DFA
-125
G
Net
z 23
0V50
/ 60
Hz
Sich
erun
g 6A
Ansc
hlus
swer
t 400
W
Rés
eau
230V
50
/ 60
Hz
Fusi
ble
6APu
issa
nce
400W
Elec
tric
mai
ns 2
30V
50 /
60 c
ycle
sFu
se 6
APo
wer
ratin
g 40
0W
Ret
e 23
0V50
/ 60
cic
liD
isp.
di p
rote
zion
e 6A
Pote
nza
alla
ccia
ta 4
00W
HSNA
Nich
t zut
reffe
ndes
stre
iche
n! P
ositi
ons
non
utili
sées
a b
iffer
!C
ance
l unn
eces
sary
item
s! C
ance
llare
ciò
che
non
inte
ress
a!23
0V A
C (
Ph+0
+E) (
L+N
+E)
Not
aus-
Tast
er 2
-poi
lg /
inte
rrupt
eur d
e se
cour
s à
2pha
ses
/ em
erge
ncy
stop
but
ton
2-po
le /i
nter
rutto
re p
er a
rrest
o d’
emer
genz
a a
due
poli
Hau
ptsc
halte
r 2-p
olig
/ in
terru
pteu
r prin
cipa
l à 2
phas
es /
mai
n sw
itch
2-po
le /
inte
rrutto
re p
rinci
pale
a d
ue p
oli
3x1,
5mm
2a b
4x0,
25m
m2
dR
ohr 1
6mm
leer
, max
. Län
ge 8
m /
tube
16m
m v
ide,
long
ueur
max
. 8m
/in
stal
latio
n tu
be 1
6mm
em
pty,
max
. len
gth
8m /
tubo
16m
m, v
uoto
, lun
ghez
za m
ass.
8m
24V
DC
(L
itzen
paa
rwei
se v
erdr
illt /
fils
tors
adés
par
pai
res
/
tw
iste
d pa
ir ca
bles
/ fil
i con
torc
iuti
a du
e a
due)
m
ax. L
änge
100
m /
long
ueur
max
. 100
m /
m
ax. l
engt
h 10
0m /
lung
hezz
a m
ass.
100
m
BDE
Bedi
enun
gsei
nhei
t / u
nité
de
com
man
de /
cont
rol u
nit /
sel
etto
re d
i fun
zion
eR
SKVe
rrieg
elun
gsko
ntak
t / c
onta
ct d
e ve
rroui
llage
/ lo
ckin
g co
ntac
t /co
ntat
to d
el b
locc
aggi
o de
lla p
orta
TOE
Türv
errie
gelu
ng /
verro
uilla
ge d
e la
por
te /
door
lock
ing
devi
ce /
bloc
cagg
io d
ella
por
taR
ADR
adar
c2x
2x0,
25m
m2
Bere
iche
für K
abel
aust
ritte
zone
s po
ur s
ortie
s de
s câ
bles
area
s fo
r cab
le o
utle
tsse
ttori
per u
scite
cav
i
50
2525
540
5
KA
KA
Mitt
e Ba
ndC
entre
de
la p
entu
reC
entre
of d
oor h
inge
Met
à ba
ndel
laKA
KA
HS
NA
RAD
RAD
TOE
RSK
BDE
d
bc
c
a
d
**
page 42 10/2003 Rev. E Manual DFA 125 G
Manual DFA 125 G 10/2003 Rev. E page 43
Atte
nzD
uran
tdi
sins
eri
Wic
hD
ie A
nei
nen
G
Avis
imp
Ne
pas
la n
uit.
Impo
The
infro
m th
e
Net
z 23
0V50
/ 60
HSi
cher
unAn
schl
u BD
Nam
eM
asss
tab
%Fr
eige
gebe
n
Erst
ellt
Dat
um
agta
tec
agC
H-8
320
Fehr
alto
rf
Leitu
ngss
chem
aSc
hém
a de
câb
lage
Cab
le la
yout
Sche
ma
dei f
iliio
ne!
e la
not
te l’
auto
mat
ism
o no
n de
ve e
sser
eto
dal
la re
te d
i ten
sion
e.
tiger
Hin
wei
s!la
ge s
oll w
ähre
nd d
er N
acht
NIE
dur
chen
eral
scha
lter v
om N
etz
getre
nnt w
erde
n.
orta
nt!
déb
rach
er le
sys
tèm
e du
rése
au p
enda
nt
rtant
not
ice!
stal
latio
n is
not
inte
nded
to b
e di
scon
nect
edm
ains
at n
ight
.
Forn
itura
eff.
da
voi s
econ
do d
ispo
sizi
oni u
ffici
ali
Lief
erun
g ba
usei
ts g
emäs
s be
hörd
liche
r Vor
schr
iftA
four
nier
par
aille
urs
selo
n sp
écifi
catio
n of
ficie
lleTo
be
furn
ishe
d by
oth
ers
acco
rdin
g to
offi
cial
regu
latio
n
* Baus
telle
Cha
ntie
rSi
teC
antie
re
Auftr
ags-
/Com
man
de-/
Ord
er-/C
omm
issi
one
Nr/N
o:
Aen
deru
ng:
A 0
1/53
km
21.
05.0
2
LS.1
2610
2A
km km
21.0
2.01
21.0
5.01
DFA
-125
G
z g 6A
ssw
ert 4
00W
Rés
eau
230V
50
/ 60
Hz
Fusi
ble
6APu
issa
nce
400W
Elec
tric
mai
ns 2
30V
50 /
60 c
ycle
sFu
se 6
APo
wer
ratin
g 40
0W
Ret
e 23
0V50
/ 60
cic
liD
isp.
di p
rote
zion
e 6A
Pote
nza
alla
ccia
ta 4
00W
HS
NA
Nich
t zut
reffe
ndes
str
eich
en! P
ositi
ons
non
utili
sées
a b
iffer
!Ca
ncel
unn
eces
sary
item
s! C
ance
llare
ciò
che
non
inte
ress
a!23
0V A
C (
Ph+0
+E) (
L+N
+E)
Not
aus-
Tast
er 2
-pol
ig /
inte
rrupt
eur d
e se
cour
s à
2pha
ses
/ em
erge
ncy
stop
but
ton
2-po
le /i
nter
rutto
re p
er a
rrest
o d’
emer
genz
a a
due
poli
Hau
ptsc
halte
r 2-p
olig
/ in
terru
pteu
r prin
cipa
l à 2
phas
es /
mai
n sw
itch
2-po
le /
inte
rrutto
re p
rinci
pale
a d
ue p
oli
3x1,
5mm
2a b
4x0.
25m
m2
dR
ohr 1
6mm
leer
, max
. Län
ge 8
m /
tube
16m
m v
ide,
long
ueur
max
. 8m
/in
stal
latio
n tu
be 1
6mm
em
pty,
max
. len
gth
8m /
tubo
16m
m, v
uoto
, lun
ghez
za m
ass.
8m
24V
DC
(L
itzen
paa
rwei
se v
erdr
illt /
fils
tors
adés
par
pai
res
/
tw
iste
d pa
ir ca
bles
/ fil
i con
torc
iuti
a du
e a
due)
m
ax. L
änge
100
m /
long
ueur
max
. 100
m /
m
ax. l
engt
h 10
0m /
lung
hezz
a m
ass.
100
m
BDE
Bedi
enun
gsei
nhei
t / u
nité
de
com
man
de /
cont
rol u
nit /
sel
etto
re d
i fun
zion
eRS
KVe
rrieg
elun
gsko
ntak
t / c
onta
ct d
e ve
rroui
llage
/ lo
ckin
g co
ntac
t /co
ntat
to d
el b
locc
aggi
o de
lla p
orta
TOE
Türv
errie
gelu
ng /
verro
uilla
ge d
e la
por
te /
door
lock
ing
devi
ce /
bloc
cagg
io d
ella
por
taRA
DR
adar
c2x
2x0,
25m
m2
Bere
iche
für K
abel
aust
ritte
zone
s po
ur s
ortie
s de
s câ
bles
area
s fo
r cab
le o
utle
tsse
ttori
per u
scite
cav
i
50
2525
540
5
KAK
A
Mitt
e B
and
Cen
tre d
e la
pen
ture
Cen
tre o
f doo
r hin
geM
età
band
ella
KAKA
KAKA
HS
NA
E
RAD
RAD
cb
dd
a bc
**a
agtatec agCH-8320 Fehraltorf kmFreigegeben
Sheet 1 of 2Gezeichnet
Geprüft bo
km
10.04.01
10.04.01
10.04.01 x xx/xx xx xx.xx.xx
AS.E.126 101
+24V(1A)
+5V(0.5A)
8300µF
63V
=
=
=
=+
1
J4
Earthingscrew
2
Lock
ing
unit
driv
er
150V
2E2
Rel.1
4
7
µP
SIREL
+5V
+5V
9
8
5
2
J6
6
1
3
5
Thermo1
J52
1
Control p.c.b.STP 126 601 000
Shield
white
red
black
brown
IKG GTRMOT
red
black
1
2
Drive unit ATE
J2
r1
r1
brown
grey
yellow
green
white
blue
+5V
0V
J1
2
3
4
1
6
5R1
(by others)as per localregulations
Flush: 14 584Surface: 14 586
Masterswitch
230V/6A/50Hz220V/6A/50Hz
Connectionsto electricmains
Neutral
Ground
Phase
EE
NN
PhPh
8
7
56
43
21
Mai
ns fi
lter
Power supply NET
THSSI
1AT
Trafo
yellow/green yellow/green
yellow/green
Chassis Hood
= Terminal for electric mains
= Terminal (not specific)
= Round plug(in part multiple)
= Plug-connect forprinted circuits
= Soldered
= Connections leading outside header
= Luminous diode LED
= Plug-terminal
Symbols
page 44 10/2003 Rev. E Manual DFA 125 G
agtatec agCH-8320 Fehraltorf kmFreigegeben
Sheet 2 of 2Art.-Nr: 16 853Gezeichnet
Geprüft bo
km
10.04.01
10.04.01
10.04.01 x xx/xx xx xx.xx.xx
AS.E.126 101
1
3
2Slave
Master
J9
+5V
µP
µP
µP
control LED
button
red
CPU1 CPU2 Ground closed +24V +35V
red red red green green
Control-LED
red
Control p.c.b.STP 126 601 000
25
26
27
28
J10
CAN-L
CAN-H
+24V
J3
twisted pair cable
J2for
BDE2+24V
0V
27
28J3
25
26
BDE-E
lateral cover
2 1
lockableby others
J5J4
+24V4
3
2
1
J8
+24V+24V
manualoperation
contin. openRocker switch
+24V
+24V+24V
+24V
Alarm
SIS
SIO
RESET
BDE2
BDE18
7
6
5
4
3 3
4
5
6
2 2
1 1
J7
J1
J2
RESET
1
2
3
4
+24V
+24V
+24V
AKI
SSK
VRK
AKA
brown
grey
white
brown
white
grey 0V
aktive = conductive
RAD/AKIActuationinternal
+24V
0V
aktive = conductive
RAD/AKAActuationexternal
+24V
5
8
7
6
o
*oTo be bridged when no SISTo be bridged when no SIO
*
aktive = open
SIOSafety open
aktive = open
SISSafety close
*
Emergency switchFire-alarmcontrol unit
(by others)
or
To be bridged if emergencyswitch is not connected*
11
12
10
9 SSK
µP1
µP2
µP
Rel.1
Locking contact13
14 VRK
active = closed
16
17
18
15Relay
contactrating
max. 1A
* de-energized closed** de-energized open
*
** Electric dooropener24V DC
maintenance plug BDE
Manual DFA 125 G 10/2003 Rev. E page 45
agtatec agCH-8320 Fehraltorf kmFreigegeben
Seite 1 von 1Art.-Nr:16.848BGezeichnet
Geprüft bo
km
15.03.01
21.05.01
13.03.01 B 02/118-1 km 6.9.02
AS.E.126 102B
Urh
eber
rech
tlich
ges
chüt
zt n
ach
DIN
34
28
twisted pair cable
twisted pair cable
26
J3 closed
27
28
12
12
25 26 27
11
11
25
CAN-Isolator
126 620 000
BDE-EOption
126 800 000
J5
28
25
26
27
DFA 125GSlave
STG 126 600 000
13
2Slave
Master
J9
+5V
µP
J3
J1
J1
J10
CAN-L
CAN-H
28
25
26
27
DFA 125GMaster
STG 126 600 000
13
2Slave
Master
J9
+5V
µP
J3J10
CAN-L
mit BDE
ohne BDE
CAN-H
page 46 10/2003 Rev. E Manual DFA 125 G
Poland
record drzwi automatczene SP.zo.o. Nowa 23 Street Stara Iwiczna PL-05-500 Piaseczno Telefon +48 22 737 71 09 Telefax +48 22 737 70 08
Denmark record BMT A/S Hovedstensvej 33 DK-2650 Hvidovre Telefon +45 36 78 23 00 Telefax +45 36 77 16 28
Spain
record puertas automáticas S.A. C/Camino de Hormigueras Nave 6 E-28031 Madrid Telefon +34 91 380 75 50 Telefax +34 91 777 32 29
Hungary record ajtó kft Leshegy ut 8 H-2310 Szigetszentmiklós Telefon +36 24 51 53 90 Telefax +36 24 51 53 92
Austria
record Türautomation Helmut Heinz Bunzl Ges.m.b.H. Zwingenstraße A-2380 Perchtoldsdorf Telefon +43 1 / 865 88 75 Telefax +43 1 / 865 88 75 14
Great Britain record automatic doors (UK) limited Unit 4 D, Albany Park Industrial Estate Frimley Road, Camberley GB-Surrey GU 15 2 PL Telephone +44 1276 692 999 Telefax +44 1276 692 747
France
record portes automatiques SA ZAC-6, rue de l’Orme Saint Germain F-91165 Champlan Cedex Téléphone +33 1 / 69 79 31 10 Téléfax +33 1 / 69 79 31 29
Niederlande Automatische deuren record B.V. Cardanuslaan 30 NL-6865 HK Doorwerth Telefon +31 26 / 33 99 777 Telefax +31 26 / 33 99 770
Germany
record Türautomation GmbH Dieselstraße 7 D-42389 Wuppertal Telefon +49 202 / 60 90 10 Telefax +49 202 / 60 90 111
Switzerland record Türautomation AG Allmendstraße 24 CH-8320 Fehraltorf Telefon +41 1 / 954 91 91 Telefax +41 1 / 954 92 00
Manual DFA 125 G 10/2003 Rev. E page 47