SUPERIORITY BY ADAPTATION
Automated
Sample Preparation:SPE –
GPC -
EVAporation
What
LCTech does
supplies innovative products and methods for the preparation and analysis of food, feed and environmental samples.
This system is designed for sample
preparation
mainly in food, feed and environmental laboratories,
but can be used in any lab in which GPC and/or any type of SPE columns are used for clean-up
FREESTYLE System -
Introduction
FREESTYLE –
The
Concept
EVAporation
SPE module
GPC module
FREESTYLE BASIC
FREESTYLE is
a system
which
is
based
on FREESTYLE BASIC and can
be
modified
with
modules
… in all imaginable combinations
Valves, syringe pump & others on top of y-axis (reduces dead volume in tubing)
FREESTYLE BASIC
FREESTYLE BASIC
xyz-robotic system
Flexbile robotic area; the appropriate „area“ can be created at any time by choosing the right racks
Rinsing port for needle
SPE Module
FREESTYLE Modules
SPE module as a 2nd z-axis
Universal manipulator for all standard SPE-/ Immuno affinity - (IAC) and Glass columns (e.g. LCTech columns) from 1 to 15 mL
Control unit for SPE module
GPC module
FREESTYLE Modules
Injection valve
High precision, double piston GPC-pump
Exchangeable sample loop
GPC-column: different sizes for all known official methods availableaccessory; not
included
in the
module
EVAporation module
FREESTYLE Modules
Heart
of the
EVAporation
system:EVAporation chamber with sensors
Integrated vacuum pump, heater & electronical devices
Solvent recovery/ solvent recycling
Water for temperature control of the vacuum chamber
FREESTYLE –
adapted
to applications
Typical
combination
of different modules:
FREESTYLE BASIC + GPC + EVAporation:
For sample preparation (clean up) for pesticides / PAH and all other analytes in fatty matrices which have to be cleaned up before transfering to analytical instruments (eg. GC or LC).
Sample preparation for soil analysis
For a faster, reliable, more reproducible and more comfortable handling of such samples customer can choose a higher level of automation: FREESTYLE BASIC
with GPC module
for clean-up and EVAporation
module
FREESTYLE –
modified
for
applications
Typical
combination
of different modules:
FREESTYLE BASIC + SPE + EVAporation:
Automation of SPE – Handling in all kind of labs
For a faster, reliable, more reproducible and more comfortable handling of such samples customer can choose a higher level of automation: FREESTYLE BASIC
with SPE module
and EVAporation
module
The
unique
design
Sorry, FREESTYLE does
not
offer 50 or
more
platforms!
FREESTYLE has just one,
but you
can create this one
according your needs, your demands, at any
time
(no service or tools needed)
Racks can be individually positioned by hooking them into a toothed plate
frame
tray with vials
= rack
Frame can be used for different kinds of vials
Tray can be taken out of frame and prepared independently
Racks –
the
key
for
flexibility
for vials from 1.0 mL to 1000 mL (e.g. standard flasks, round bottom flasks, TurboVap, Büchi, test-tubes…)
racks can be cooled or heated
With protection for light sensitive samples
Vials and flasks can be sealed with septa
= You can choose between r.a. 30 different racks. And if you cannot find the appropriate rack we are sure that we can design it. Ask LCTech!
Racks –
the
key
for
flexibility
Powerful Software
Selection of individual
modules
or
combination
of different functions within a single method
(eg. SPE +EVA or GPC+EVA)
no hardware
changes
necessary!
Allows intuitive handling
and easy usage in daily routine
Indicates most of the logical failures done by the customer
choosing the wrong parameters
Always included in the purchase price of modules
FREESTYLE™
–
system
features
Integral system features
Extensive safety devices: - Possibility of immediate emergency stop
in case of danger or to prevent any dangerous situation
- Collisions recognition
with the possibility to proceed without loss of sample
All liquid containing tubing is located outside
the instrument, thus easily accessible and strictly separated from any electric wiring
Plausibility check
of software input
Software is always included
in the modules
Standards of development and production & safety guidelines
Developed and produced at highest level according to Machine Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast), including CE certification.
Developed and produced according to ISO 9001:2008.
CE labelled safety guidelines
FREESTYLE™ - Standards of production
For all standard SPE-cartridges/columns from 1 mL up to 15 mL
For all standard Immunoaffinity columns (1 mL/3 mL) IAC-columns can be stored in the rack sealed with a tight cap, so buffer does not flow out. IAC remains „fresh“ until you decide to use it
For glass columns for max. dimensions 105 x 17,5 ID (length x diameter)
SPE Module
SPE Module
Positive pressure
for all steps in which liquids are used
One rack
for all kind of columns: reusable adapters allow an easy to change and mixed setup for all kinds of columns
Columns can be moved to any
place in the robotic area
Standard three solvents, upgrade option up to six
solvents
Software allows the transfer of nearly any manual method straight to an automation
SPE Module & handling of SPE cartridges/SPE columns
SPE Module
Method
Development
Move next step from the basic tools with drag & drop to second column
The default button remains in the basic tools and can be choosen again
The collected steps in the second column build the method
Each button there can be individually changed and adopted by using the „bars“.
Application:determination
of the
Hydrocarbon
Oil Index in water/soil
according
to EN ISO 9377-2 (H53 Method)
For this very common routine application a special rack is used
36 samples can be handled in sequence
If desired FREESTYLE system (Evaporation module necessary) can evaporate them right away down to ≤
1.0 mL, sample can be
transferred in GC-Vial: ready for analysis
SPE Module
EVAporation
at its
best!
EVAporation Module
All necessary
items
are
integrated (only chiller for solvent recovery additionally needed)
Heart of the system: EVAporation chamber
frequency controlle diaphragm pump (Vacuubrand)
all sensoric items for detection of final volume
heating system with two zones a) with water for fast EVAporation b) electrical heater for the extended cone
for very sensitive evaporation
EVAporation
at its
best!
EVAporation Module
You
can
use
these
unique
and unbeatable
functions:
automated EVAporation down to a final volume
final volume can be choosen between 0.5 mL and 5.0 mL
final volume can be set by software; no manual adjustment of the sensors!
final volume can be set individually for each method = that means each sample in a sample list can have a different final volume
EVAporation either by vacuum/heat or by nitrogen/heat (option) for very sensitive samples
EVAporation
at its
best!
EVAporation Module
More
of these
unique
and unbeatable
functions:
solvent exchange (fluid/fluid or dryness/resolved)
360° C rinsing of the EVAporation chamber
Concentrate can be fractionated
Transfer of the concentrated sample with the robotic needle and not aspirated through a tube
Option: the whole system can be charged with nitrogen
Last but
not
least:
automated calibration of the EVAporation chamber at any time for reliable and high precision final volume
EVAporation
method
development; what
you
can
use
and modify:
Sample aspiration
Vacuum process
Blow-down with nitrogen or compressed air
Sample withdrawal from vacuum chamber
Solvent exchange
Fill-up and aliquotation
Vacuum chamber rinsing
EVAporation module
EVAporation
at its
best!
Double piston pump, esp. modified for low pressure applications (esp. with the appropriate pressure sensor)
Flow rate from 0.1 mL to 50 mL/min
GPC columns: - different dimensions
and
- different solvents for all official sample clean up methods worldwide
GPC Module
GPC method
development
(1):
5 different possibilites of injection
for all known applications:
- from sample loop overfill (traditional clean up for pesticide analysis)
- up to quantitative transfer by several injections from one glass (incl. 360° spray rinsing)
- and collection of these runs in one flask (dioxin-analysis)
Definition of forerun, main run
(total, partial or sequential fractionation) and tailings
Number and size of sample and collect vials
Depth of needle immersion
GPC Module
GPC method
development
(2):
Column injection counter
Flow rate
(GPC module)
Min. and max. pressure shut-off
Sample aspiration speed
(important for solvents like DCM)
Column type
and specification, respectively
UV Detector
data acquisition (yes/no)
GPC Module
GPC Module
Software: GPC method screen; the whole adjustment of a GPC method can be done in this easy to handle screen.
FREESTYLE -
General Accessories
Liquid level
switch
for organic solvent (e.g. for waste bottle)
Check of liquid level of waste bottle: Interruption of process, if bottle is empty / full (displayed in software)
Upgrade: 3 to 6 solvents:- Highly recommended
for SPE applications
Blow-down
function
for
nitrogen
and compressed
air:- necessary for usage of nitrogen/air for evaporation- and drying of columns in SPE-function;
FREESTYLE -
Accessories
for
SPE and EVA
FREESTYLE –
Accessories
for
GPC module
UV Fixed Wave Length Detector (254nm) for
GPC column
performance
test; necessary software is integrated
in the software package for FREESTYLE-systems
FREESTYLE -
SUPERIORITY BY ADAPTATION
Flexibility
on highest
level:
FREESTYLE BASIC+ GPC-Module+ EVAporations-Module+ SPE-Module
In one sample list, there can be combined any method totally independent from each other:
e.g.: 1. run: GPC2. run: GPC+ EVA3. run: GPC + EVA + SPE4. run: EVA
There is no hardware modification necessary at any time!