49
Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Talk Title HereAuthor Name, Company

Automated Out-of-Band Management

with Ansible and RedfishJose Delarosa, Dell EMC

October 23, 2017

Page 2: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Before we start

• Thank you for coming

• Please ask questions: It’s OK to interrupt

• If time runs out, happy to talk to you afterwards

Page 3: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Who am I

• Jose Delarosa (@jdelaros1)– Linux Engineer at Dell EMC (13 years)

– Part-time technology evangelist

– Part-time developer

– Part-time systems engineer

– Full-time problem solver

Page 4: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Session content

1. iDRAC: provides out-of-band management

2. Redfish: provides scalability

3. Ansible: provides automation

4. Putting it all together:

Page 5: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

iDRAC Overview

Page 6: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Integrated Dell Remote Access Controller (iDRAC)

• Embedded chip on a PowerEdge server, independent of the server’s

operating system and main power:

– Provides device inventory

– Detects hardware failure

– Manage power: turn off, on, hard reset

• Has its own Ethernet port, usually connected to separate

management network

• Referred to as “out-of-band” (OOB) management, as opposed to “in-

band” management provided by the operating system.

Page 7: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Login

Page 8: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Dashboard

Page 9: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Storage Controller

Page 10: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Hard Drives

Page 11: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Fans

Page 12: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Temperatures

Page 13: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

System Event Logs

Page 14: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Simple Out-of-Band Management

ManagementNetwork

Page 15: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Redfish Overview

Page 16: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

What is Redfish?

• Open source, open industry standard specification published by

the DMTF for hardware management.

• A RESTful API used to obtain information and exert control over

servers via an OOB controller.

• Built on a modern tool-chain, which includes HTTPS, JSON and

the OData standard.

• A redfish “command” is sent as a URI request, so a client can be

any application on a server, workstation or mobile device.

Page 17: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Scalable Out-of-Band Management

ManagementNetwork

https://<idrac>/redfish/v1/Systems/Systems.Embedded.1

{ Health OK HealthRollup OK State Enabled }

Page 18: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

What can we do with Redfish?

• Get server health status

• Alert on server health status changes

• Retrieve hardware and firmware inventory

• Reset, reboot, and power control servers

• Access system logs

• Configure OOB controller

• Much more!

https://www.dmtf.org/standards/redfish

Page 19: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Redfish API tree structure

Page 20: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

iDRAC operation APIs

Dell Redfish API URLs Comments

/redfish/v1/Managers

/redfish/v1/Managers/iDRAC.Embedded.1

/redfish/v1/Managers/iDRAC.Embedded.1/Actions/Manager.Reset Used to perform iDRAC reset

/redfish/v1/Managers/iDRAC.Embedded.1/NetworkProtocolReports information about iDRAC's network services. Includes Web server, SNMP, vMedia, Telnet, SSH, IPMI & KVM.

/redfish/v1/ Managers/iDRAC.Embedded.1/SerialInterfaces iDRAC BMC serial interface

/redfish/v1/ Managers/iDRAC.Embedded.1/SerialInterfaces/<Serial-key>

/redfish/v1/Managers/iDRAC.Embedded.1/LogServices

/redfish/v1/Managers/iDRAC.Embedded.1/LogServices/Sel Access to server System Event Log

/redfish/v1/Managers/iDRAC.Embedded.1/LogServices/Lclog Access to Lifecycle Controller Log

/redfish/v1/Managers/iDRAC.Embedded.1/LogServices/Sel/Actions/LogService.ClearLog Used to clear LC Log

/redfish/v1/Managers/iDRAC.Embedded.1/VirtualMedia Status of iDRAC virtual media

/redfish/v1/Managers/iDRAC.Embedded.1/VirtualMedia/<media-type>

/redfish/v1/Managers/iDRAC.Embedded.1/EthernetInterfaces iDRAC network interface

/redfish/v1/Managers/iDRAC.Embedded.1/EthernetInterfaces/<FQDD>

/redfish/v1/Managers/iDRAC.Embedded.1/AccountService

/redfish/v1/Managers/iDRAC.Embedded.1/Accounts iDRAC user accounts

/redfish/v1/Managers/iDRAC.Embedded.1/Accounts/<Account-Id>

Page 21: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Chassis Inventory APIs

Dell Redfish API URLs Comments

/redfish/v1/Chassis

/redfish/v1/Chassis/System.Embedded.1 Top-level URI for server chassis

/redfish/v1/Chassis/System.Embedded.1/Thermal System temperatures

/redfish/v1/Chassis/System.Embedded.1/Sensors/Fans Reports fan status for server and FX2 chassis

/redfish/v1/Chassis/System.Embedded.1/Sensors/Fans/<Fan-FQDD>

/redfish/v1/Chassis/System.Embedded.1/Sensors/Temperatures Reports thermal data for server and FX2 chassis

/redfish/v1/Chassis/System.Embedded.1/Sensors/Temperatures/<Sensor-FQDD> <Sensor-FQDD> addresses each temperature probe

/redfish/v1/Chassis/System.Embedded.1/Power Power consumption and supply status

/redfish/v1/Chassis/System.Embedded.1/Power/PowerControl

/redfish/v1/Chassis/System.Embedded.1/Sensors/Voltages

/redfish/v1/Chassis/System.Embedded.1/Sensors/Voltages/<Voltage-FQDD> <Voltage-FQDD> addresses each voltage output

/redfish/v1/Chassis/System.Embedded.1/Power/PowerSupplies

/redfish/v1/Chassis/System.Embedded.1/Power/PowerSupplies/<PSU-FQDD> <PSU-FQDD> addresses each power supply

/redfish/v1/Chassis/System.Embedded.1/Power/Redundancy/<PSRedundancy-FQDD> <PSRedundancy-FQDD> addresses power supply redundancy

Page 22: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

System status APIs

Dell Redfish API URLs Comments

/redfish/v1 Top-level API access

/redfish/v1/Systems Server inventory and status information access

/redfish/v1/Systems/<ServiceTag+nodeid>

/redfish/v1/Systems/System.Embedded.1/Actions/ComputerSystem.Reset Server reset operation

/redfish/v1/Systems/System.Embedded.1/Processors Details on CPUs

/redfish/v1/Systems/System.Embedded.1/Processors/<Processor-FQDD>

/redfish/v1/Systems/System.Embedded.1/EthernetInterfaces Reports NIC IP address, DHCP and DNS information.

/redfish/v1/Systems/System.Embedded.1/EthernetInterfaces/<EthernetInterface-FQDD> Example <EthernetInterface-FQDD> = NIC.Embedded.1-1-1

/redfish/v1/Systems/System.Embedded.1/EthernetInterfaces/<EthernetInterface-FQDD>/Vlans

/redfish/v1/Systems/System.Embedded.1/EthernetInterfaces/<EthernetInterface-FQDD>/Vlans/<Vlan-FQDD>

/redfish/v1/Systems/System.Embedded.1/Storage/Controllers Manages storage controllers (i.e. PERC).

/redfish/v1/Systems/System.Embedded.1/Storage/Controllers/<Controller-FQDD>Typical <Controller-FQDD>=RAID.Slot.N-1; describes details of controller, backplane, enclosure, attached drives

Page 23: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Registries, Sessions, Tasks and Event APIs

Dell Redfish API URLs Comments

/redfish/v1/Registries/Messages/En PowerEdge message registry

/redfish/v1/odata Enables OData clients to navigate iDRAC Redfish resources

/redfish/v1/$metadataProvides a metadata document describing the resources and collections that are available at the iDRAC Redfish service root URI

/redfish/v1/$metadata#<Collection or a single resource>

/redfish/v1/JSONSchemas Schema descriptions for all supplied data

/redfish/v1/JSONSchemas/<file>

/redfish/v1/SessionService Redfish session management

/redfish/v1/Sessions

/redfish/v1/Sessions/<SessionId>

/redfish/v1/TaskService Redfish internal task management

/redfish/v1/EventService Redfish event management

/redfish/v1/EventService/Actions/EventService.SubmitTestEvent

/redfish/v1/EventSubscriptions

/redfish/v1/EventSubscriptions/<Subscription ID>

Page 24: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Example: Get system health

$ curl -s https://<idrac>/redfish/v1/Systems/System.Embedded.1 -k -u root:calvin | jq .Status

{

"Health": "OK",

"HealthRollUp": "OK",

"State": "Enabled"

}

Page 25: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Example: Get storage controller information

$ curl -s https://<idrac>/redfish/v1/Systems/System.Embedded.1/Storage/Controllers/RAID.Slot.4-1 -k -u root:calvin |

jq '{name: .Name, status: .Status.Health}’

{

"name": "PERC H740P Adapter ",

"status": "OK"

}

Page 26: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Example: Get HDD information

$ curl -s https://<idrac>/redfish/v1/Systems/System.Embedded.1/Storage/Controllers/RAID.Slot.4-1 -k -u root:calvin | jq .Devices[

{

"CapacityBytes": 599550590976,

"Manufacturer": "SEAGATE",

"Model": "ST600MM0238",

"Name": "Physical Disk 0:1:0",

"Status": {

"Health": "OK",

"HealthRollup": "OK",

"State": "Enabled"

}

},

{

"CapacityBytes": 599550590976,

"Manufacturer": "SEAGATE",

"Model": "ST600MM0238",

"Name": "Physical Disk 0:1:1",

"Status": {

"Health": "OK",

"HealthRollup": "OK",

"State": "Enabled"

}

},

Page 27: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Example: Get fan information

$ curl -s https://<idrac>/redfish/v1/Chassis/System.Embedded.1/Thermal -k -u root:calvin | jq '.Fans[] | {name:.Name, reading: .Reading, health: .Status.Health}'

{

"name": "System Board Fan1",

"reading": 5640,

"health": "OK"

}

{

"name": "System Board Fan2",

"reading": 5640,

"health": "OK"

}

{

"name": "System Board Fan3",

"reading": 5640,

"health": "OK"

}

..

Page 28: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Example: Get thermal information

$ curl -s https://10.9.165.12/redfish/v1/Chassis/System.Embedded.1/Thermal -k -u root:calvin | jq '.Temperatures[] | {name:.Name, readingCelsius: .ReadingCelsius, health: .Status.Health}'

{

"name": "CPU1 Temp",

“readingCelsius": 29,

"health": "OK"

}

{

"name": "CPU2 Temp",

“readingCelsius": 28,

"health": "OK"

}

{

"name": "System Board Exhaust Temp",

“readingCelsius": 29,

"health": "OK"

}

..

Page 29: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Example: Get system event logs

$ curl -s https://<idrac-ip>/redfish/v1/Managers/iDRAC.Embedded.1/Logs/Sel -k -u root:calvin | jq '.Members[] | {date: .Created, message: .Message, severity: .Severity}'

..

{

"date": "2017-09-26T13:33:00-05:00",

"message": "Power supply redundancy is lost.",

"severity": "Critical"

}

{

"date": "2017-09-26T13:32:53-05:00",

"message": "The power input for power supply 2 is lost.",

"severity": "Critical"

}

{

"date": "2017-09-16T10:37:59-05:00",

"message": "Log cleared.",

"severity": "Ok"

}

Page 30: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Redfish Roadmap

• Version 1.x focused on servers. Will expand over time to cover

storage and network infrastructure.

• Will add devices over time to cover new technologies (i.e.

NVDIMMs, Multifunction Network Adapters)

• SNIA is developing Swordfish, which builds upon Redfish’s local

storage management to address advanced storage devices.

• Open source efforts (http://github.com/dmtf)– Client libraries (Python, Java, PowerShell)

– Redfish Mockup Creator / Server

– Redfishtool (CLI utility similar to ipmitool)

Page 31: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Ansible Overview

Page 32: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

What is Ansible

• Automation software makes repetitive tasks easy

• Agentless minimum footprint

• No database back end easy to install and use

• Defines desired state OK to run task more than once

• Remote tasks are run in parallel Efficient

• Easier to learn and use than shell scripts

Page 33: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Ansible use cases

OpenStack• Compute nodes• Storage nodes• Controller nodes

IT Security Hardening• Firewall rules• Remove invalid users• Install latest updates

Container Management• Stop/remove containers• Refresh container images• Deploy with new images

1-to-n management Executes tasks in parallel

Page 34: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Popular Ansible use cases

• Cloud infrastructure deployments

• Application installation & configuration

• Container management

• Security compliance

• IT audits

• OOB systems management

Page 35: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Ansible definitions

• Task: A task is the smallest unit of work. It can be an action like “Install a package”, “Remove a user”,

“Create a firewall rule” or “Copy this file to this location”.

• Play: A play is made up of tasks. For example, the Play “Prepare a database” is made up of tasks:

– Task: “Install the database package”

– Task: “Set password”

– Task: “Create database”

– Task: “Set database access”.

• Playbook: A playbook is made up of Plays. For example the playbook “Prepare a web site with a

database” is made of up Plays: 1) “Set up the database server” and 2) “Set up the web server”.

Playbook: Setup my web application

Play 1: Setup database

Task 1:Install mysql package

Task 2:Create database customer_db

Play 2: Setup web server

Task 1:Install httpd package

Task 2:Configure site for TLS

Page 36: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Example: Automating routine tasks

$ groupadd admin$ useradd -c Sys Admin -g admin -m sysman$ mkdir /opt/tools$ chmod 755 /opt/tools$ chown sysman /opt/tools$ yum -y install httpd$ yum -y update$ systemctl enable httpd$ systemctl start httpd$ rm /etc/motd

- name: daily tasks hosts: my_100_daily_servers tasks: - group: name=admin state=present - user: name=sysman comment="Sys Admin" group=admin - file: path=/opt/tools state=directory owner=sysman mode=0755 - yum: name=httpd state=latest - yum: name=* state=latest - service: name=httpd state=started enabled=yes - file: path=/etc/motd state=absent

Say you provision 100 servers every

day and you run these commands

in each server:

The same commands can be placed in an Ansible

playbook and executed in 100 servers:

yaml format = easy to learn! yaml format = easy to organize!

Page 37: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

One more Ansible definition

• Module

– An Ansible module is a program where a task is implemented.

– A playbook is where you specify the instructions (tasks) you want to run; a module

is the code to implement those instructions.

– Modules can be written in any language but most

popular is Python.

– If you are an operator, you will work mostly with

playbooks.

– If you are a developer, you will work mostly with

modules.

Page 38: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Scalable & Automated Out-of-Band Management

ManagementNetwork

{ Health OK HealthRollup OK State Enabled }

https://<idrac>/redfish/v1/Systems/Systems.Embedded.1

Page 39: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Putting it all together:iDRAC + Redfish + Ansible

Page 40: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Ansible module and playbooks for iDRAC

• Manage your entire Dell EMC IT infrastructure (servers,

routers, switches, storage) from an Ansible controller.

• Automated monitoring, provisioning, firmware updates at

scale.

• Open source, so you can write your own extensions as

needed and contribute back to the community.

• To be included as an Ansible community module.

Page 41: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

• Server Power On/Off; Reboot; Hard Reset

• Install BIOS, Configure BIOS, Reset to Default

• Configure iDRAC (CRUD operations):

– User & Password Management

– NTP and Time Zone settings

– Storage (RAID, Physical Disks, Virtual Disks)

• System Inventory – H/W, Firmware, Sensor

• OS Deployment – remote file share, vMedia

• Import / Export SCP – remote file share, vMedia

• Backup and Restore– Server Profiles

Key lifecycle management tasks

• Upgrade using DSU (Dell Server Update) or DUEC (Dell Update Engine for Consoles)

– Get list of available and applicable updates

– Firmware Upgrade

– BIOS Upgrade

– OS Drivers Upgrade

• Job Management– Check JOB status– Create JOB– Delete JOB– Create JOB Queue– Delete JOB Queue

• Get Logs– Export LC logs– Export System Event Logs

Page 42: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Implementation example: get system inventory

Playbook: Execute: Output:

Page 43: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Inventory spreadsheet

• Collect inventory data, maintain in spreadsheet or database

Server iDRAC IP Model IP address BIOS CPU Type RAM Service Tag Status

webserver-1 192.168.2.10 PowerEdge R630 10.0.1.30 2.3.4 2Intel(R) Xeon(R) CPU E5-2630 v3 @

2.40GHz128 5W14Q47 OK

webserver-2 192.168.2.11 PowerEdge R630 10.0.1.31 2.3.4 2Intel(R) Xeon(R) CPU E5-2630 v3 @

2.40GHz128 5XR7Q32 OK

webserver-3 192.168.2.12 PowerEdge R630 10.0.1.33 2.3.2 2Intel(R) Xeon(R) CPU E5-2630 v3 @

2.40GHz128 5XT3QYY OK

appserver-1 192.168.2.13 PowerEdge R830 10.0.1.34 2.3.2 4Intel(R) Xeon(R) CPU E5-2630 v3 @

2.60GHz512 5XR7QXY OK

dbserver-1 192.168.3.10 PowerEdge R730 10.0.2.30 2.1.2 2Intel(R) Xeon(R) CPU E5-2630 v3 @

2.33GHz256 5XR7Q67 OK

dbserver-2 192.168.3.11 PowerEdge R730 10.0.2.31 2.3.4 2Intel(R) Xeon(R) CPU E5-2630 v3 @

2.33GHz256 5WT4Q37 OK

dbserver-3 192.168.3.12 PowerEdge R730 10.0.2.32 2.3.4 2Intel(R) Xeon(R) CPU E5-2630 v3 @

2.33GHz256 5WR4Q12 OK

dbserver-4 192.168.3.13 PowerEdge R730 10.0.2.33 2.3.4 2Intel(R) Xeon(R) CPU E5-2630 v3 @

2.33GHz256 5TT1Q21 OK

Page 44: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Implementation example: get HDD info and health

Playbook: Output:

Page 45: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Implementation example: get BIOS boot order

Playbook:Execute: Output:

Page 46: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

https://github.com/dell/idrac-ansible-module

Development is ongoing. Contributions are welcome!

Page 47: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Resources

• iDRAC with Lifecycle Controller: http://dell.to/2qdBd0y

• Redfish API specification: http://bit.ly/2gb9VBj

• Dell EMC PowerEdge Redfish API Overview: http://dell.to/2odsH1p

• iDRAC Redfish API Reference Guide: http://dell.to/2oyjMTy

• Getting started with Ansible: http://bit.ly/2oCj5xy

• jq JSON parser: https://stedolan.github.io/jq/

Page 48: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017

Thank you

Q & A

Page 49: Automated Out-of-Band Management Talk Title Here with Ansible … · 2017-10-19 · Automated Out-of-Band Management with Ansible and Redfish Jose Delarosa, Dell EMC October 23, 2017