75
Automated Low Voltage Intelligent Networks Chris Lowsley

Automated Low Voltage Intelligent Networks

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Automated Low Voltage Intelligent Networks

Automated Low Voltage

Intelligent Networks

Chris Lowsley

Page 2: Automated Low Voltage Intelligent Networks

About EA Technology

Page 3: Automated Low Voltage Intelligent Networks

Our heritage

1966

•Electricity

Council

Research

Centre

1990

•Electricity

privatisation

•Transition to

commercial

provider of

technology

services

1994

•Reformed as EA

Technology

2004

•Employee-owned

2016

•200 employees

•c£18m (c€24m)

turnover

Delivering innovation for years

Design and

build

Instruments

Consulting

Services

Technical Site

Services

Training &

Power Skills

Page 4: Automated Low Voltage Intelligent Networks

Our Products

Medium and High Voltage Electrical Partial Discharge Solutions

4

Detection

Location

Monitoring

Page 5: Automated Low Voltage Intelligent Networks

Our Products

Intelligent fault location and restoration solutions for Low Voltage

networks

5

Page 6: Automated Low Voltage Intelligent Networks

Our Technical Services

6

A range of services to help our clients understand the condition of their substations, cables, transformers and overhead lines

Oil diagnosticsTransformer condition

assessment

Switchgear condition

assessmentSubstation earthing

Cable condition

assessmentOverhead line services Failure investigations

Lightning protection

and location

Page 7: Automated Low Voltage Intelligent Networks

Our Consultancy and Software

7

Activity that helps inform strategic choices, driving cost-efficiencies

for those who own and operate energy networks

..and how to extend, manage and integrate solutions into the electrical system

A focus on the electrical assets from the component through to investment planning..

Page 8: Automated Low Voltage Intelligent Networks

A company with a global reach

Regional offices: USA, UAE, SEA, China, Australia

Page 9: Automated Low Voltage Intelligent Networks

LV Solutions Business

Page 10: Automated Low Voltage Intelligent Networks

LV Solutions

Cable Sniffer 2

ALVIN Reclose

Key Focus:

⚫ automated self healing LV distribution networks

⚫maximising network uptime

⚫minimising downtime

Page 11: Automated Low Voltage Intelligent Networks

ALVIN Reclose Equipment

Page 12: Automated Low Voltage Intelligent Networks

Intro Video

Page 13: Automated Low Voltage Intelligent Networks

Background

Page 14: Automated Low Voltage Intelligent Networks

Early Prototype

Page 15: Automated Low Voltage Intelligent Networks

Replacement for an LV Fuse

Can be directly

inserted into fuse

way

92/83*mm

Back Up

Fuse

Protected

Able to Trip & Close

Automatically

Transient

FaultsOverloads

Reduces

SAIDI’s & SAIFI’s for

Intermittent Faults

<3mins

Able to give fault

information

Pre-fault

detection

Impedance

to fault

* Next batch of equipment

Page 16: Automated Low Voltage Intelligent Networks

Other Fuse Replacements

* UK Experience

Page 17: Automated Low Voltage Intelligent Networks

ALVIN Reclose is not a…

Fault Conditioning Tool

Page 18: Automated Low Voltage Intelligent Networks

ALVIN Reclose is not a…

Or is it??It has a limited conditioning capability up to 2000A

during the SafeOn process

Page 19: Automated Low Voltage Intelligent Networks

So what is ALVIN Reclose?

1. ALVIN is a cost effective replacement for a fuse that will try to safely restore customer supplies in less than 3 mins

2. It should be installed after 1st fuse operation in case of a transient fault or overload

3. It is a capital investment to be left on the network indefinitely or until the circuit is proved to be healthy

4. If one ALVIN Reclose unit prevents 75 customers being off supply for more than 1 hour, it will have paid for itself*

* UK Experience

Page 20: Automated Low Voltage Intelligent Networks

Basic Design

Page 21: Automated Low Voltage Intelligent Networks

Operating Principles

ALVIN Reclose has an Innovative Design

• Thyristor takes all the duty of making and breaking

• Contactor provides low losses when switched

• Thyristor operates at current zero crossing on the sine wave

• Thyristor provides arc free switching

Feeder Cable

BS88Fuse

11kV/415VContactor

Thyristor

Current Zero

Page 22: Automated Low Voltage Intelligent Networks

SafeON

Page 23: Automated Low Voltage Intelligent Networks

SafeONTM

Making

Fault detection and current limiting technology

Inrush Current Limits (configurable)

Page 24: Automated Low Voltage Intelligent Networks

Why it Helps Us....

SafeONTM

Making

Fault detection and current limiting technology

Page 25: Automated Low Voltage Intelligent Networks

Arc Free Switching

Page 26: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Close Operation

Cable

ALVIN Reclose device is open, no conduction.

Page 27: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Close Operation

Cable

ALVIN Reclose device intends to close. SafeONTM controls current via thyristor

IT

Page 28: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Close Operation

Cable

No fault found, contactor is closed while thyristor is conducting

IT

Page 29: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Close Operation

Cable

Once switch is closed, thyristor switches off, current flows through switch

I

Page 30: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Open Operation

Cable

Current flowing through switch under normal conditions

I

Page 31: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Open Operation

Cable

ALVIN Reclose device intends to open so thyristor switched on

IT

Page 32: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Open Operation

Cable

Contactor is opened while thyristor is conducting

IT

Page 33: Automated Low Voltage Intelligent Networks

Arc-free switching

SafeONTM

Principles

Open Operation

Cable

Thyristor switches off at zero crossing; ALVIN Reclose device is open, no conduction.

Page 34: Automated Low Voltage Intelligent Networks

Benefits of Arc-Free Switching

1. Multi-shot Capability (1000 ops)

2. No closing onto a permanent fault

3. No Arcing during switching = Safer

4. No Arcing = No contact wear

5. No contact wear = No Maintenance

6. No Maintenance = No return to Supplier

7. No Return to supplier = Less Cost

Page 35: Automated Low Voltage Intelligent Networks

Protection Characteristics

Page 36: Automated Low Voltage Intelligent Networks

ALVIN Acting as a Fuse

BS88 Fuse Curve:

⚫Batches of fuses have

tolerance band

⚫ALVIN is programmed to

beat fastest part of

tolerance band

⚫ALVIN has an

accumulator to mimic

heating of fuse

Fastest Tolerance

Page 37: Automated Low Voltage Intelligent Networks

Fuse Settings

Settings:

⚫315A

⚫400A

⚫ * Single Trip Mode for

➢ Live Working

➢ Single shot

Page 38: Automated Low Voltage Intelligent Networks

Benefits of ALVIN Protection

Settings:

⚫ Programable protection settings

⚫Can model any LV fuse characteristic

⚫Can provide hybrid models

Fuse curve with instantaneous trip

⚫Number of reclose attempts can be changed

before lockout

Page 39: Automated Low Voltage Intelligent Networks

ALVIN Reclose Ratings

Page 40: Automated Low Voltage Intelligent Networks

Typical Installations

Page 41: Automated Low Voltage Intelligent Networks

Installations

Page 42: Automated Low Voltage Intelligent Networks

Installations

Page 43: Automated Low Voltage Intelligent Networks

Stand Alone Mode

Page 44: Automated Low Voltage Intelligent Networks

How to use ALVIN Reclose

Stand Alone Mode – Transient Fault or Overload

Successful Reclose(Set at 3 attempts)

Leave ALVIN in Situ until Permanent Fault Identified

ProtectMonitor

&Record

Page 45: Automated Low Voltage Intelligent Networks

How to use ALVIN Reclose

Stand Alone Mode – Permanent Fault

Replace Fuse

Will not Reclose due to Permanent fault(set at 3 attempts)

Locate Fault – TDR & SnifferRepair Fault

Page 46: Automated Low Voltage Intelligent Networks

ALVIN Reclose with Communications

Page 47: Automated Low Voltage Intelligent Networks

Advanced Mini Portal 2 (AMP2)

AMP2

⚫GSM Comms

⚫WiFi Linked

⚫24V Power Supply

Wireless Link

⚫ Links ALVIN to AMP2

Page 48: Automated Low Voltage Intelligent Networks

Advanced Mini Portal 2 (AMP2)

•Provides conduit between

connected equipment and

Cloud Database

•Sim card inserted into AMP2

•Wirelessly linked to ALVIN

Reclosers

Page 49: Automated Low Voltage Intelligent Networks

How does it link together?

LVCloudTrial

Server

Fitted in Substation

ALVIN Reclose

Wireless Link

ALVIN Mini Portal

Page 50: Automated Low Voltage Intelligent Networks

Cloud Server

Page 51: Automated Low Voltage Intelligent Networks

LVCloud Server

Page 52: Automated Low Voltage Intelligent Networks

LVCloud Server – ALVIN Reclose

Page 53: Automated Low Voltage Intelligent Networks

LVCloud Server – ALVIN Reclose

Page 54: Automated Low Voltage Intelligent Networks

LVCloud Waveform Capture (pre-fault)

Page 55: Automated Low Voltage Intelligent Networks

LVCloud Waveform Capture (pre-fault)

Page 56: Automated Low Voltage Intelligent Networks

LVCloud Server - TDR

Page 57: Automated Low Voltage Intelligent Networks

LVCloud - TDR

Page 58: Automated Low Voltage Intelligent Networks

LVCloud TDR Waveform Capture

Page 59: Automated Low Voltage Intelligent Networks

LVCloud TDR Waveform Capture

Page 60: Automated Low Voltage Intelligent Networks

Health and Safety

Page 61: Automated Low Voltage Intelligent Networks

Health & Safety

Installation/Removal of ALVIN Reclose

Distribution Safety Rules to be adhered to

Wear the Correct PPE

The ALVIN Reclose unit must be withdrawn from fuse

way to establish a Point of Isolation

Health & Safety

Page 62: Automated Low Voltage Intelligent Networks

Other Equipment in ALVIN Range

Page 63: Automated Low Voltage Intelligent Networks

⚫ Self contained fully automated LinkBox switching

device

⚫ Low Cost Solution (OPEX and CAPEX)

⚫ Automated operation depending on network

conditions

ALVIN LinkSense

Page 64: Automated Low Voltage Intelligent Networks

Link Box Automation

Page 65: Automated Low Voltage Intelligent Networks

Link Box automation

The following applications may be done by remote control from the control centre or automatically by LinkSensedevice

Page 66: Automated Low Voltage Intelligent Networks

LinkSense ICT

Page 67: Automated Low Voltage Intelligent Networks

LinkSense BAL

Page 68: Automated Low Voltage Intelligent Networks

Fully Automated LV network

Page 69: Automated Low Voltage Intelligent Networks

SMART Grid Video

Page 70: Automated Low Voltage Intelligent Networks

Low Voltage Network

Network, equipment,

Substation LV Reclosers

Interconnected Network with Link Boxes

Page 71: Automated Low Voltage Intelligent Networks

Low Voltage Network

Network, equipment, external comms

Substation LV Reclosers

Comm’s

Comm’s

Page 72: Automated Low Voltage Intelligent Networks

Low Voltage Network

Network, equipment, external comms

Comm’s

Link Box controller

Link Box controller

Link Box controller

Comm’s

Substation LV Reclosers

Link Box Equipment

Page 73: Automated Low Voltage Intelligent Networks

Low Voltage Network

Network, equipment, external comms, internal comms

Comm’s

Link Box controller

Link Box controller

Link Box controller

Comm’s

PLCComms

Substation LV Reclosers

Link Box Equipment

Page 74: Automated Low Voltage Intelligent Networks

Automated Low Voltage Network

Network, equipment, external comms internal comms, control+automation

ETI

Comm’s

PowerOn Fusion, Web Interface, Mobile Phone

Link Box controller

Link Box controller

ETI

Link Box controller

Comm’s

PLCComms

EthernetGSMDNP3SCADA

Substation LV Reclosers

Link Box Equipment

Page 75: Automated Low Voltage Intelligent Networks

Email [email protected]

For further information

Thank You