16
1 The world leader in serving science Automate Your Water and Wastewater Analysis Using GALLERY Discrete Analyzers David Glutz Product Specialist

Automate Your Water and Wastewater Analysis Using GALLERY … · 2018. 8. 13. · Thermo Scientific™ Gallery™ Gallery Plus Capacity Up to 200 tests/hour Up to 350 tests/hour Incubation

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • 1

    The world leader in serving science

    Automate Your Water and Wastewater Analysis Using GALLERY Discrete Analyzers David Glutz Product Specialist

  • 2

    Konelab /Arena

    PRIME 60/30

    Product offering

    Key product launches over 40 years!!

    In 70’s

    Olli CD

    (1977)

    System

    Olli 3000

    (1972)

    In 80’s In 90’s In 2000’s

    Specific

    Proteins

    (1987)

    Clinical

    Chemistry

    Reagents

    (1984)

    Progress

    Family

    (1983)

    Ion

    Selective

    Electrodes

    (1980)

    Konelab/Aq

    uakem &

    Arena

    family

    (1998)

    System

    Reagents

    (1994)

    Gallery / Indiko (2010)

    Arena (2005)

    TCAutomation (2001)

  • 3

    Basis of Measurement - Spectrophotometry

    • Spectral range 275 – 880 nm

    • 12 filter positions or ”channels”

    • Market specific

    • Standard factory installed on all new equipment

    • Fast measurement with a flash lamp

    • Main and side wavelengths measured at the same time

    • Water blank measured in all wavelengths at the same time

  • 4

    Optional Electrochemical Module (ECM)

    • Automate all of your tests including Conductivity and

    pH measurements

    • Measuring range for

    • conductivity 20 µS/cm - 112 mS/cm

    • pH 2 – 12

    • Sample types

    • Natural water, waste water, drinking water, etc.

  • 5

    • Chloride

    • Fluoride

    • Nitrate+Nitrite

    • Hydrazine, Vanadium or

    NEW Enzymatic

    reduction!!!!

    • Nitrite

    • Ortho-Phosphate

    • Sulfate

    • TKN

    • TP

    • Alkalinity

    • Aluminium

    • Ammonia

    • Boron

    • Bromide

    • Calcium

    • Chromium (VI)

    • Copper

    • Cyanide (Total)

    • Iron (Ferrous and

    Total)

    • Magnesium

    • Manganese

    • Molybdenum

    • Phenol

    • Silica

    • Sulfide

    • Thiocyanate

    • Total Hardness

    • Urea

    • Zinc

    • pH

    • Conductivity

    Wide Selection of EPA Approved Test Methods for Both DW and WW

    Additional Tests

  • 6

    Enzymatic Reductase for Nitrate+Nitrite Determination

    Replaces Cadmium Reduction

    • No more column regeneration!

    • No reagent waste disposal cost!

    • Method developed specifically on

    Thermo GALLERY Discrete Analyzers!

    • Excellent performance in saline and

    other tough matrices!

  • 7

    Range of Discrete Analyzers for Water Analysis

    Thermo Scientific™ Gallery™ Gallery Plus

    Capacity Up to 200 tests/hour Up to 350 tests/hour

    Incubation

    temperature 25 to 60 ˚C 25 to 60 ˚C

    Optional units

    pH and Conductivity pH and Conductivity

    • Temp can be specific per test.

    • Default setting at 37 oC

  • 8

    Discrete Analysis Process

    1. Cuvette entry point

    2. Cuvette loader

    3. Incubator

    4. Sample racks

    5. Sample disk

    6. Reagents

    7. Reagent disk

    8. Barcode reader

    9. Reagent dispenser

    10. Sample dispenser

    11. Mixer

    12. Photometer unit

  • 9

    Discrete Analysis Routine Workflow

  • 10

    Easy Reagent Handling

    • Reagent volumes from 2 to 240 µL

    • Reagent containers

    • 10 and 20 mL vials

    • Barcoded system reagent containers are automatically identified

    • Non-system reagents can be entered without barcodes

    • Clearly displayed

    • Real-time reagent volume

    • Remaining test capacity

    • Expired reagents flagged automatically

  • 11

    Flexible Sample Management

    • Sample volumes from 2 to 240 µL

    • Any mix of sample containers

    • 0.5, 2.0 and 4.0 mL sample cups

    • 5.0, 7.0 or 10.0 mL sample tubes

    • Automatic identification via an internal barcode reader

    • Tests can be requested individually or by using a profile

  • 12

    Flexible, Reliable, Temperature-Stabilized Measurement

    • Several calibration options

    • Factor, Bias, Linear, Logit-log, Spline, Polynomial, Point-to-point

    • Possibility to add up to four reagents per test

    • Automation even for the most complex methods

    • Real-time QC program, specific to each test, assures

    reliable performance

    • Measurement temperature can be

    adjusted between 25 oC and 60 oC

    • Default setting at 37 oC

  • 13

    Comprehensive Data Handling

    • Application parameter values readable from barcode or

    electronically from a file

    • Results

    • Calculated from both measured

    and off-line results

    • Automatically flagged in case of

    • Abnormal values

    • Out-of-limit QC values

    • Long term storage of results

    • Associated calibrations

    • Reagent lot data

    • Cumulative QC data

  • 14

    Reporting Options

    • Reports available

    • Spreadsheet export for further

    calculations

    • Export to LIMS via Excel

    (.CSV)

    • Printouts

    • PDF files

  • 15

    Intuitive User Interface

    • Graphic user-interface

    • Embedded help menu

    • Includes context-sensitive help

    • Available in different languages

    • Secure and traceable data

    handling

    • ‘User Manager’ - Different user

    groups can have

    different access rights

    • Touch screen option

  • 16

    Thank You!