13
Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0) 1727 83 66 11 [email protected] www.aurora.eu.com All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

Aurora Ltd

6 Apex Park

Welwyn Garden City

AL7 4SW

T: +44 (0) 1727 83 66 11

[email protected]

www.aurora.eu.com

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Page 2: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

2

Customer:

Product code:

Customer:

Product code:

Product

description:

Integrating

Sphere Test

Request Number:

Tested By

Engineer:

Test Date:

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

Page 3: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

3

The luminaire is not treated as symmetric.

Ambient temperature 25±1 ºC

* - Measured Lumen output value relative to M. Rated Lumen

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Measured Lumen (lm) 2310 1449

Measured Useful Lumens within

120degrees

1800 1149

Max Luminous Intensity (cd) 789 501

Beam Angle (º) 116.4 115.2

LOR* -

Power factor 0.954

Power (Including Gear, W) 42.45

Source Description

Manufacturer AURORA

M. Rated Lumens (lm) 3300

M. Rated Watts (W) 40

Colour Temperature (K) 3000

Source Type LED

Gear Description

Manufacturer AURORA

Part Number AU-LPDD1

Dimensions

Luminaire Dims (mm) 1195x295x10

Optical Dims (mm) 1152x250

Accessories

Description -

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

(FLIPPED)

Page 4: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

4

Customer:

Product code:

Customer:

Product code:

Product

description:

Integrating

Sphere Test

Request Number:

Tested By

Engineer:

Test Date:

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

Page 5: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

5

Customer:

Product code:

Customer:

Product code:

Product

description:

Integrating

Sphere Test

Request Number:

Tested By

Engineer:

Test Date:

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

Page 6: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

09/12/2015 6

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

Page 7: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

09/12/2015 7

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

Page 8: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

09/12/2015 8

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

(FLIPPED)

Page 9: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

09/12/2015 9

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

(FLIPPED)

Page 10: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

09/12/2015 10

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

(FLIPPED)

Page 11: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

09/12/2015 11

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

(FLIPPED)

Page 12: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

09/12/2015 12

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08

Customer: AURORA

Product Code: AU-SU101B/30

Product Description: 1200mm x 300mm Suspended Up/Down LED Light Panel

Photometric Test Request

Number:

PTR1633

Tested by Engineer: Sunny Ram

Test Date: 08/12/2015

Page 13: Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 ...db.aurora.co.s3.amazonaws.com/FamilyData/23263/13360/SKUData/… · Sphere Test Request Number: Tested By Engineer: Test

1

3

Equipment Information: Goniophotometer:: Radiant Imaging PM-NFMS-0800 & ProMetric CCD Imaging Photometer

Illuminance Meter:: KONICA MINOLTA T-10/T-10M

Power analyser: EVERFINE PF9811

Uninterruptible Power Supply:: BORRI B400-030-B

PM-NFMS is a Near-Field Imaging Goniophotometer, which combines a motorised goniometer stage with a

ProMetric CCD imaging photometer to perform a near-field angular analysis of the luminance and colour from

LEDs, luminaires and solid state lighting. ProSource software then scales this to far-field luminous intensity

data from which standard photometric files are generated (IESNA, EULUMDAT).

The PM-NFMS employs a ProMetric CCD imaging photometer to record spatially-resolved images of the

near-field luminance emitted from the light source. Luminance (units of cd/m2) is the optical property one

measures when working up close to the light source. Spatially-resolved images of the source luminance are

recorded in Radiant Imaging's proprietary ProSource (.rs8) format for one angle of azimuth and elevation at a

time. The associated, motorised goniometer stage scans the device under test over ± 88° in all directions.

Radiant Imaging's ProSource software then performs a ray-tracing operation to scale the near-field luminance

readings to equivalent far-field illuminance values. Standard photometric files in the IESNA (.ies) and

EULUMDAT (.ltd) format can then be generated.

Specification:

+ The PM-NFMS0800 can be used to measure a 600 x 600 2D luminaire, mounted off-axis.

Approx. Max. Linear Luminaire Length (mm) 1600

Max. Luminaire Weight (kg) 25

Recommended Max. Luminaire Size (mm) 865 x 535

600 x 600+

Max. Luminaire Size for Recessed Fittings 700 x 355

Operating Range, Azimuth ± 90°

Operating Range, Elevation ± 90°

All measurements are taken in accordance with BS EN 13032 and IES LM-79-08