450 Riverside Dr • Wyalusing PA, 18853 • Phone 570-746-1888 • Fax 570-746-9286AUI-
Member of AMCADivision of Mestek
MODEL EA-22SD-EA22-
Miami-Dade HVHZ Louver • 4” Deep • 45° Dual Drainable Blades • Stationary • Extruded Aluminum Page 1
arrowunited.com
17.08
09-01-01
August 2017
In the interest of product development, Arrow United reserves the right to make changes without notice.
Item # QtyWidth Height Width Height
MullionType Location
Opening Size Louver Size Screens Union Made
Arch. / Eng.: EDR: ECN: Job:
Contractor:
Project: Date: DWN: DWG:
Louver Width (in.)
60” Max. Section
Mullion (Typ.)1¼” (Typ.)
Withstands pressures up to ±150 PSF.
Visit our Miami-Dade Listing Page for the latest NOA information:https://goo.gl/DJ5UtM
Standard Materials and Construction
Options
Notes
Test Methods
Louver Sizes
Min Panel Max Single Panel
12"W x 12"H 60”W x 96”H
FRAME: .125” thick (nominal) extruded aluminum, 6063-T52/T6 alloy. BLADE: .125” thick (nominal) extruded aluminum, 6063-T52/T6 alloy. Blades approximately 4” on centers. LOUVER FACE: Full width sill with head and blades contained within jambs. Welded construction. SCREEN: (When indicated, in a removable frame.) ½”flattenedaluminum(.051”thick), -or- ½” sq. mesh, intermediate double-crimped aluminum wire, .063” dia., -or- ¹⁸⁄16 mesh, .011” dia. aluminum wire, insect screen. FINISH: Mill
Passed the following Miami-Dade County Florida Test Protocols: • TAS (PA) 201 • TAS (PA) 202 • TAS (PA) 203
Finish - Baked Enamel, Kynar, AnodizeExtended Sill
1. Nominal deductions will be made to the opening size given.2. Approximate shipping weight is 6.0 lbs./sq.ft.
Windload requirements may limit panel sizes.
4”
Louver Height(in.)
1”(Typ.)
Not to scale.
4”
450 Riverside Dr • Wyalusing PA, 18853 • Phone 570-746-1888 • Fax 570-746-9286AUI-
Member of AMCADivision of Mestek
SD-EA22-MODEL EA-22
Miami-Dade HVHZ Louver • 4” Deep • 45° Dual Drainable Blades • Stationary • Extruded Aluminum Page 2
arrowunited.com
17.08
09-01-01
August 2017
Performance Data
Ratingsdonotincludeeffectsofascreen.
Pres
sure
Dro
p (in
. w.g
.)
Pressure Drop
Velocity (fpm) x 100 thru Free Area3 754 6 8 109
.03
.06
.05
.04
.01
.08
.07
.02
.30
.09
.10
.20
.40
.50
Intak
e
12 14 16 18 20
Intake air converted to standard air density. Tested to AMCA Standard 500-L, Figure 5.5.
Model EA-22Test Unit Size
48” x 48”
10009000
.02
.06
.04
.10
.08
.12
.16
.14
.20
.18
.22
.26
.24
.30
.28
Velocity (fpm) thru Free Area
Water Penetration
1100 1200 1300
1075 (FPM) Beginning Point of Water Penetration
Wat
er (o
z./ft
.²) F
ree
Area
- 15
Min
ute
Inte
rval
Model EA-22Test Unit Size
48” x 48”
Width (in.)
12" 18” 24” 30” 36” 42” 48” 54” 60”
Hei
ght (
in.)
12” .31 .50 .70 .90 1.09 1.29 1.48 1.68 1.87
24” .81 1.31 1.82 2.33 2.84 3.35 3.86 4.36 4.87
36” 1.30 2.12 2.94 3.77 4.59 5.41 6.23 7.05 7.87
48” 1.80 2.93 4.07 5.20 6.34 7.47 8.37 9.74 10.87
60” 2.29 3.74 5.19 6.64 8.08 9.53 10.98 12.43 13.88
72” 2.79 4.55 6.31 8.07 9.83 11.59 13.35 15.12 16.88
84” 3.28 5.36 7.43 9.51 11.58 13.65 15.73 17.80 19.88
96” 3.78 6.17 8.55 10.94 13.33 15.72 18.10 20.49 22.88
Free Area (sq.ft.)
ArrowUnitedIndustriescertifiesthattheModel EA-22 shown herein is licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCACertifiedRatingsProgram.TheAMCACertifiedRatingsSealappliestoWaterPenetration and Air Performance Ratings only.
Pressure Drop: .15 in. w.g. at 1000 fpm (intake) Free Area: 8.37 sq.ft. = 52% for 48”W x 48”H sample tested in accordance with AMCA Standard 500-L.Beginning Point of Water Penetration: 1075 fpm
*
Visit our Miami-Dade Listing Page for the latest NOA information:https://goo.gl/DJ5UtM
450 Riverside Dr • Wyalusing PA, 18853 • Phone 570-746-1888 • Fax 570-746-9286AUI-
Member of AMCADivision of Mestek
MODEL EA-22SD-EA22-
Miami-Dade HVHZ Louver • 4” Deep • 45° Dual Drainable Blades • Stationary • Extruded Aluminum Page 3
arrowunited.com
17.08
09-01-01
August 2017
Installation Details
⁵⁄16” - 18 UNC x 1½” Hex head steel bolt withflatwasher,lockwasher, and nut. 4” from ends and 8” on center.
4”x3”x⅜”A36steelangle 2¾” long (2) per
mullion end.
½” x 2” A307 Hex head plated steel
boltwithflatwasher,lockwasher, and nut (2) per mullion end.
⅝”x2¼”sleeveanchor(Concrete) at head/sill.
Sealant by others.
C5 x 6.7 A36 Steel
4”
Visible Vertical Mullion Detail
2” x 2” x ¼” thick, 2” long within 4” from ends of either aluminum or A36
steel as required per load table.⁵⁄16” - 18 UNC x 1½” Hex head steel boltwithflatwasher,lockwasher,and nut. 4” from ends and 8” on
center. 4”x3”x⅜”A36steelangle2¾” long (2) per mullion end.
(2) #14 x 1¼” Hilti Tek screw
Concrete Head/Sill
½” x 2” A307 Hex head plated steel bolt withflatwasher,lockwasher,andnut(2)
per mullion end.
⅝”x2¼”sleeveanchor(1) per channel end.(1) per head & sill.
Extended Sill (Optional)
Sealant by others.
C5 x 6.7 A36 Steel4”
1¼”
2⅛”
9½”±
¼” Max.
Head/Sill Detail
2” x 2” x ¼” thick, 2” long within 4” from ends of either aluminum or A36 steel as required per load table.
(2) #14 x 1¼” Hilti Tek screw
(Concrete)⅝”x2¼”sleeveanchor at jamb.
(Masonry)⅜”x1⅞”sleeveanchor at jamb.
Red Head Dynabolt at jamb.Masonry or Concrete
Sealant by others.
4”
1¼”
¼” Max.
Jamb Detail
Visit our Miami-Dade Listing Page for the latest NOA information:https://goo.gl/DJ5UtM