11
Augenabteilung am St. Franziskus Hospital Münster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial interest. ASCRS, April 9-14, 2010, Boston ASCRS, April 9-14, 2010, Boston

Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Embed Size (px)

DESCRIPTION

Augenabteilung am St. Franziskus Hospital Münster Methods In this comparative (self-controlled) single-center study 40 eyes were treated with bilateral EPI-LASIK (Zyoptix XP microkeratome with EPI Separator, Bausch & Lomb) and 40 eyes with LASEK. Epithelial flap repositioned Epithelial flap discarded Epi-LASIK20 LASEK20

Citation preview

Page 1: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital Münster

Influence of Epithelial Flap on LASEK and Epi-LASIK

Suphi Taneri, Saskia OehlerAuthors have no financial interest.

ASCRS, April 9-14, 2010, BostonASCRS, April 9-14, 2010, Boston

Page 2: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Purpose Purpose

• To elucidate the influence of the epithelial flap after EPI-LASIK and LASEK for the correction of low to moderate ametropia on visual recovery, epithelial closure, pain, and haze formation

Page 3: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

MethodsMethods

• In this comparative (self-controlled) single-center study 40 eyes were treated with bilateral EPI-LASIK (Zyoptix XP microkeratome with EPI Separator, Bausch & Lomb) and 40 eyes with LASEK.

Epithelial flap repositioned

Epithelial flapdiscarded

Epi-LASIK 20 20 LASEK 20 20

Page 4: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Results: Visual recoveryResults: Visual recovery

Mean uncorrected distance visual acuity was better in EPI-LASIK in the absence of an epithelial flap on day 1, 2, and 4.After 3 months the uncorrected distance visual acuity was nearly similar between all groups. (* statistically significant, ** highly statistically significant)

*

Page 5: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Results: Pain PerceptionResults: Pain Perception

Pain scores decreased continually from day 1 to day 4 in all groups and showed no significant difference between the 4 groups.

Page 6: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Results: Epithelial ClosureResults: Epithelial Closure

*

(* statistically significant)

Page 7: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Results: Haze FormationResults: Haze Formation

EPI-LASIK Mean Range

Flap repositioned

0.45 ± 0.37 0-1

Flap discarded 0.43 ± 0.59 0-2.5

LASEK Mean Range

Flap repositioned

0.35 ± 0.46 0-1

Flap discarded 0.33 ± 0.44 0-1

Haze levels (Fantes classification) at 3 months

Page 8: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Results: Perceived Change in Snellen Results: Perceived Change in Snellen LinesLinesDifference between corrected distance visual acuity

preoperatively and uncorrected distance visual acuity postoperatively

Page 9: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Results: Efficacy IndicesResults: Efficacy Indices

Page 10: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

Results: Safety IndicesResults: Safety Indices

Page 11: Augenabteilung am St. Franziskus Hospital Mnster Influence of Epithelial Flap on LASEK and Epi-LASIK Suphi Taneri, Saskia Oehler Authors have no financial

Augenabteilung am St. Franziskus Hospital MünsterAugenabteilung am St. Franziskus Hospital Münster

ConclusionConclusion

No clinically significant differences of LASEK and EPI-LASIK could be detected regardless of epithelial flap retention in terms of visual recovery, epithelial closure time, pain perception, and haze formation.Treatment modalities may be used at the surgeon’s discretion.