Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Attend our Open House on August 29th
• Chamber: 3m Semi-Anechoic• Emissions Sites: 10m and 30m (OATS)• Specialties: Medical devices, transmitters, ground penetrating radar, telecom, consumer products, laser and ultrasound, military EMC• Reporting: Test data delivered same day testing is completed. • NARTE-Certified Engineers on-site• Additional services: Electrical safety testing, performance testing, SEMI F47, telecom, NSF, and military gasket testing
EMC LAB SPECIFICATIONS
Attend our Open House on August 22nd
• Chambers: 3m, 10m Semi-Anechoic • Emissions Sites: 10m Semi-Anechoic• Radiated Emission: 60Hz – 40GHz• Specialties: Intentional transmitters for FCC, IC, EU, Japan, and Taiwan; medical devices: EMC MIL-STD; GR-1089-CORE, Sections 2 and 3• NARTE-Certified Engineers on-site• Additional services: Electrical safety testing, GR-63-Core, Section 4.2.2.2, fire resistance
Attend our Open House on September 7th
• Chambers: (Immunity & Emissions) 3m, 10m Semi-Anechoic • Radiated Emissions from 20 Hz to 40 GHz• ESD to 30 kV• Specialties: Medical devices, transmitters for US, Canada and EU, NEBS GR-1089 Sections 2 and 3, EMC for audio/video equipment for EU• NARTE-Certified Engineers on-site• Additional services: Electrical safety testing, telecom testing
Attend our Open House on November 1st
• Chambers: 3m Semi-Anechoic • Emissions Sites: 3m, 10m and 30m (OATS)• Specialties: Medical devices, transmitters, automotive, lighting fixture testing• NARTE-Certified Engineers on-site• Additional services: Electrical safety testing
Attend our Open House on September 19th
• Chamber: 3m Semi-Anechoic Chamber• Emissions Sites: 3m and 10m (OATS)• Specialties: Industrial, lighting, ITE, medical, laboratory, intentional radiators, FCC Part 18, Part 15, Product safety GMAP • Reporting: Test data delivered same day testing is completed.
EMC LAB SPECIFICATIONS
Attend our Open House on August 29th
• Chamber: 5m Semi-Anechoic capable of producing field strengths up to 600v/m. • Emissions Sites: 3m and 10m (OATS)• Specialties: Medical devices, transmitters, EMC portion of safety standards (ie. UL991)• Reporting: Test data delivered same day testing is completed. • Strengths: Sole AEMCLAP, GM and Ford Motor Company approved lab in the region. • NARTE-Certified Engineers on-site• Additional services: Environmental performance (vibration, temp/humidity cycling, thermal shock) and SEMI F47
To request a private tour of this facility, call 1-800-WORLDLAB
• Chamber: 3m and 10m Semi-Anechoic Chamber• Specialities: NEBS, EMC, Wireless• Reporting: Test data delivered same day testing is completed. • Strengths: Only 3rd party laboratory in Kentucky. On-site Specific Absorption Rate (SAR) testing capabilities.• Additional services: Environmental (temperature, humidity, altitude, accelerated weathering), earthquake and vibration testing, SAR and wireless testing, fire spread testing, acoustical testing, lightning surge and power fault testing
To request a private tour of this facility, call 1-800-WORLDLAB
• Chamber: 3m Semi-Anechoic • Emissions Sites: 3m, 10m (OATS)• Specialties: ITE Medical Industrial Limited MIL-STD-461/462, Limited RTCA DO-160 Radio• Reporting: Test data delivered same day testing is completed. • NARTE-Certified Engineers on-site• Strengths: Quick report turns, engineering advice available to clients during testing, training class for clients, continually building comfort level with client
To request a private tour of this facility, call 1-800-WORLDLAB
• Chamber: 3m Semi-Anechoic • Emissions Sites: 3m and 10m (OATS)• Specialties: Medical devices, transmitters, EMC portion of safety standards (ie. UL991)• Reporting: Formal test report delivered within 15 business days following completion of testing• NARTE-Certified Engineers on-site• Additional services: Electrical safety
EMC LAB SPECIFICATIONS
To request a private tour of this facility, call 1-800-WORLDLAB
• Chamber: 3m Semi-Anechoic • Safety and EMC Field Engineering Service Available• Reporting: Test data delivered within 5 business days once testing is completed • NARTE-Certified Engineers on-site• Strengths: Fast turn-around, best of breed engineers• Additional services: Electrical safety testing, IP testing (dust chamber, water testing), flammability of plastics, and sanitation (NSF), Gas Fired Product Testing
CONTACT INFORMATION:800-WORLDLAB
www.intertek-etlsemko.com/[email protected]
Page 1 of 6 - November 2006
Semi-anechoic chamber (emissions or immunity)Key Sheltered EMI site Open Area Test Site (OATS)
EMC Capabilities - Americas
Intertek EMC LabSemi-Anechoic
ChambersEmissions Test Sites (OATS)
Frequency Range Electrical Power Load
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50 Hz 60 Hz
Boulder, CO 30 Hz to 40 GHz
30 Hz to 18 GHz 0-50 V, 25 A
120/208/240 100 A/phase 480 V, 100 A
120/208/240 100 A/phase480 V, 100 A
5T
Boxborough, MA 20 Hz to 220 GHz
20 Hz to 18 GHz
0-30 V, 120 A 0-60 V, 50 A
240 V, 100 A 440 V, 50 A
100/208 V, 100 A380 V, 50 A
2T(2) 5T
Duluth, GA 20 Hz to 40 GHz
10 kHz to 18 GHz 0-60 V, 60 A 230/400 V
50 A/phase120/208/240 V 100/100/100 A 4T
Laguna Niguel, CA 9 kHz to 18 GHz
10 kHz to 1 GHz - 0-230 V
45 kVA120/208/230/480 V
30 A/phase 8T
Lexington, KY 60 Hz to 18 GHz
10 kHz to 10 GHz
0-48V, 170 A 0-80 V, 25 zA 0-400 V, 2 A
0-230 V 12 kVA/phase
120/208/480 V 100 A/phase
Littleton, MA 5m
5m 30 Hz to
40 GHz
60 Hz to 18 GHz
(200 V/m, 10 kHz-18 GHz)
0-65 V, 30 A 230 V, 30 A
120 V, 100 A 208 V, 100 A/phase
230 V, 30 A 480 V, 30 A/phase
4T
Menlo Park, CA 50 Hz to 40 GHz
10 kHz to 18 GHz
0-48 V, 50 A 0-250 V, 16 A
230 V, 30 A 380 V, 50 A
120/208/480 V 50 A 8T
Mississauga, ON 150 kHz to 1GHz
27MHz to 1GHz 0-150 V, 7 A 240 V, 40 A
480 V, 30 A120/240 V, 60 A
480 V, 40 A
Oakdale, MN 20 Hz to 21 GHz
10 kHz to 2 GHz 0-250 V, 16 A 230/380 V, 50 A 120/208 V, 100 A
480 V, 50 A 8T
Page 2 of 6 - November 2006
Semi-anechoic chamber (emissions or immunity)Key Sheltered EMI site Open Area Test Site (OATS)
EMC Capabilities - Americas
Intertek EMC LabSemi-Anechoic
ChambersEmissions Test Sites (OATS)
Frequency Range Electrical Power Load
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50 Hz 60 Hz
Richardson, TX 20 Hz to 18 GHz
10 kHz to 2 GHz
50 V DC, 40 A 150 V DC, 3 A 230/380 V, 50 A 120/208 V, 100 A
480 V, 50 A 8T
Totowa, NJ 9 kHz to 2 GHz
10 kHz to 2 GHz 0-60 V, 10 A 230/400 V
40 A/phase120/208/230/480 V
40 A/phase 4.4T
Page 3 of 6 - November 2006
Semi-anechoic chamber (emissions or immunity)Key Sheltered EMI site Open Area Test Site (OATS)
EMC Capabilities - APAC
Intertek EMC LabSemi-Anechoic
ChambersEmissions Test Sites (OATS)
Frequency Range Electrical Power Load
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50 Hz 60 Hz
Taiwan 9kHz to 40GHz
150kHz to 2GHz
12–48V30A
100–240V25A
110–230V25A 200kg
Hong Kong a x2
9kHz to 40GHz
30GHz to 3GHz 24V 240V
13A120V13A
Shenzhen bx2
30MHz to 18GHz
80MHz to 3GHz 24V 230V
16A110V16A
Guangzhou 2 shield rooms for conducted emission, power disturbance and immunity tests only(mainly for house appliance and luminaire)
Shanghai 20Hz to 26.5GHz
150kHz to 4GHz
12–72V100A
100–240V25A
100–240V25A 800kg
Shanghai (IAS) 20Hz to 26.5GHz
10KHz to 8GHz (200V/m capability and 600V/m)
0–100V100A
120/208/230V30A
120/208/230V30A 2T
a. Full anechoic chamber used in Hong Kong for Immunity onlyb. Semi-anechoic chamber will be built in 1st quarter of 2007
Page 4 of 6 - November 2006
Semi-anechoic chamber (emissions or immunity)Key Sheltered EMI site Open Area Test Site (OATS)
EMC Capabilities - Japan
Intertek EMC LabSemi-Anechoic
ChambersEmissions Test Sites (OATS)
Frequency Range Electrical Power Load
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50 Hz 60 Hz
Kashima No. 1 X X 9k to 40GHz 100-240V/5.7kVA 100-240V/5.7kVA 5T
Kashima No. 3 X X X 9k to 40GHz 100-240V/17kVA 100-240V/17kVA 10T
Kashima No. 7 X X X 9k to 40GHz 100-240V/10kVA 100-240V/10kVA 5T
Kashima No. 8 * * *30M-1000MHz
CALTS according to
CISPR16
Kashima No. 12 X X 9k to 40GHz 10k to 18GHz 100-240V/20kVA 100-240V/10kVA 10T
Kashima KIT X 10k to 18GHz 100-240V/10kVA 100-240V/10kVA
Matsuda No. 1 X X 9k to 40GHz 100-240V/15kVA 100-240/15kVA 5T
Matsuda No. 2 X X 9k to 40GHz 100-240V/15kVA 100-240/15kVA 5T
Matsuda No. 3 X X 9k to 40GHz 100-240V/15kVA 100-240/15kVA 5T
Matsuda No. 4 X X 9k to 40GHz 100-240V/15kVA 100-240/15kVA 5T
Page 5 of 6 - November 2006
Semi-anechoic chamber (emissions or immunity)Key Sheltered EMI site Open Area Test Site (OATS)
EMC Capabilities - Japan
Intertek EMC LabSemi-Anechoic
ChambersEmissions Test Sites (OATS)
Frequency Range Electrical Power Load
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50 Hz 60 Hz
Matsuda No. 5 X X 9k to 40GHz 100-240V/15kVA 100-240/15kVA 5T
Matsuda No. 7 X 10k to 18GHz 100-240V/6kVA 100-240V/6kVA 1T
Matsuda No. 8 X 10k to 18GHz 100-240V/6kVA 100-240V/6kVA 1T
Nagano No. 1 X X 9k to 40GHz 100-240V/4kVA 100-240V/4kVA 1T
Nagano No. 2 X X 9k to 40GHz 100-240V/6kVA 100-240V/6kVA 1T
Nagano No. 3 X X 9k to 40GHz 100-240V/2kVA 100-240V/2kVA 1T
Nagano Compact Chamber X 80 to
1000MHz 100-240V/2kVA 100-240V/2kVA 0.2T
Tochigi No. 1 X X 9k to 40GHz 100-240V/6kVA 100-240V/6kVA 5T
Tochigi No. 2 X X 9k to 40GHz 100-240V/6kVA 100-240V/6kVA 5T
Tochigi No. 3 X X 9k to 40GHz 100-240V/6kVA 100-240V/6kVA 2T
Page 6 of 6 - November 2006
Semi-anechoic chamber (emissions or immunity)Key Sheltered EMI site Open Area Test Site (OATS)
EMC Capabilities - EMEA
Intertek EMC LabSemi-Anechoic
ChambersEmissions Test Sites (OATS)
Frequency Range Electrical Power Load
3m 10m 30m 3m 10m 30m Emissions Immunity DC 50 Hz 60 Hz
Sweden x2 20Hz to
18GHz10kHz to 18GHz
0-54V200A
100-240V63A
100-240V16A 50Kg-6T
UK X X X 9kHz to 40GHz
10kHz to 40GHz 200V/m
0-100V200A
0-415V75A per phase
0-110V16A 2T
Germany 9kHz to 18GHz
150kHz to 3GHz
12–48V25A
100–240V16A
110–230V16A 800kg
Italy a 9kHz to 18GHz
150kHz to 4.5GHz
0-80V80A
240V-22A320V-16A
240V-22A320V-16A 1T
a. Italy: full anechoic chamber