Threshold Enviroy1053 Tourmaline Street, San Diego, CA 92109y Phone: (858) 688-3522 ASBESTOS AND LEAD BUILDING SURVEY Residential Properties 1010, 1022, and 1050 N Twin Oaks Valley Road San Marcos, CA 92069 Prepared for: Mr. Dave Brown Tetra Tech, Inc. 1230 Columbia Street, Suite 1000 San Diego, CA 92101 Phone: 619-525-7188 March 24, 2021 Threshold Project No. 210216 TET-NTOVR Survey _____________________ Gavin Seedorf Project Manager Cal-DOSH Certified Asbestos Consultant #12-4981 Cal-DPH Lead Inspector #22987

ASBESTOS AND LEAD BUILDING SURVEY

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ASBESTOS AND LEAD BUILDING SURVEY

Threshold Enviroy1053 Tourmaline Street, San Diego, CA 92109y Phone: (858) 688-3522

ASBESTOS AND LEAD BUILDING SURVEY Residential Properties 1010, 1022, and 1050 N Twin Oaks Valley Road San Marcos, CA 92069 Prepared for: Mr. Dave Brown Tetra Tech, Inc. 1230 Columbia Street, Suite 1000 San Diego, CA 92101 Phone: 619-525-7188 March 24, 2021 Threshold Project No. 210216 TET-NTOVR Survey

_____________________ Gavin Seedorf Project Manager Cal-DOSH Certified Asbestos Consultant #12-4981 Cal-DPH Lead Inspector #22987

Page 2: ASBESTOS AND LEAD BUILDING SURVEY

1-1

TABLE OF CONTENTS Section Page 1.0 INTRODUCTION ............................................................................................................ 2 2.0 SITE DESCRIPTION ...................................................................................................... 4 3.0 ASBESTOS BACKGROUND AND SURVEY METHODOLOGY ............................ 6

3.1 ASBESTOS BACKGROUND AND REGULATIONS ................................................................... 6 3.2 ASBESTOS SURVEY METHODOLOGY .................................................................................. 8

4.0 ASBESTOS SURVEY RESULTS ................................................................................. 10 4.1 CONFIRMED ASBESTOS-CONTAINING MATERIALS .......................................................... 10 4.2 NON-ACMS OR NON-SUSPECT MATERIALS..................................................................... 10

5.0 LEAD BACKGROUND AND SURVEY METHODOLGY ....................................... 12 5.1 LEAD BACKGROUND AND REGULATIONS ........................................................................ 12 5.2 LEAD SURVEY METHODOLOGY ........................................................................................ 12

6.0 LEAD SURVEY RESULTS .......................................................................................... 14 6.1 SURVEY RESULTS FOR LEAD-BASED PAINT AND LEAD-CONTAINING SURFACES ........... 14

7.0 CONCLUSIONS ............................................................................................................. 15 7.1 ASBESTOS CONCLUSIONS ................................................................................................. 15 7.2 LEAD CONCLUSIONS ......................................................................................................... 15

8.0 RECOMMENDATIONS ............................................................................................... 17 9.0 STATEMENT OF LIMITATIONS .............................................................................. 18 FIGURES Figure 1 1010 House – Asbestos and Lead XRF Sample Locations Figure 2 1010 Barn – Asbestos and Lead XRF Sample Locations Figure 3 1010 Barn, Shed, and Pool – Asbestos and Lead XRF Sample Locations Figure 4 1022 House – Asbestos Sample Locations Figure 5 1022 House and Pool – Lead XRF Sample Locations Figure 6 1050 House – Asbestos and Lead XRF Sample Locations TABLES Table 1 Summary of Asbestos-Containing Materials Table 2 Summary of Lead-Based Paint PHOTOGRAPHS Asbestos Photograph Record Lead Photograph Record APPENDICES Appendix A Personnel Certifications Appendix B Asbestos Analytical Laboratory Reports and Chain-of-Custody Documents Appendix C XRF Data Appendix D CDPH 8552 Inspection Form

Page 3: ASBESTOS AND LEAD BUILDING SURVEY

2

1.0 INTRODUCTION Tetra Tech, Inc. (Client) retained Threshold Enviro (Threshold) to conduct an asbestos and lead survey to identify hazardous building materials which may be present in the subject buildings. The subject buildings are three single-family residences located at 1010, 1022, and 1050 N Twin Oaks Valley Road, San Marcos, California (the Site). The field portion of the survey took place in February 2021, and is comprised of two parts: an asbestos survey and a lead paint survey. The asbestos and lead surveys were performed by a California-certified professional (personnel certifications can be found in Appendix A). Asbestos Survey The asbestos survey performed was comprised of a visual inspection and bulk sampling of potential asbestos-containing materials (ACMs) and asbestos-containing construction materials (ACCMs). ACM is any construction material containing 1.0% or more asbestos by weight. ACCM is any construction material containing greater than 0.1% asbestos and less than 1.0% of asbestos by weight. For the purpose of simplicity, ACM in this report refers to any construction material that contains asbestos. Bulk samples of potential ACMs were collected using destructive techniques in select representative locations. The scope of work for this survey did not include testing for airborne asbestos or asbestos in settled dust. If a material was unable to be sampled (due to safety or access), then it may be assumed as an ACM and treated as such until adequately sampled and analyzed. The objective of the survey was to identify, estimate quantities, and assess the condition/friability of asbestos in accessible areas of the interior of the subject buildings. These objectives were met by completing the following tasks: x Perform a visual inspection for suspect ACMs following Asbestos Hazard Emergency

Response Act (AHERA) sampling protocol as a guideline to identify sources of friable and non-friable ACMs;

x Determine locations of homogenous building materials suspected of containing asbestos, collect, and analyze representative bulk samples of suspect material for asbestos content; and

x Prepare this report summarizing the inspection activities, findings, conclusions, and recommendations.

Lead Survey The lead survey performed was comprised of a visual inspection and non-destructive testing of potential lead-based paint (LBP) or lead-containing surfaces (LCS). LBP is considered any painted surface with levels of lead equal to or greater than 1.0 milligrams per square centimeter (mg/cm2). LCS is considered any surface or coating with levels of lead equal to or greater than 1.0 mg/cm2. The lead testing was conducted using a portable Niton XL2 Gold X-Ray Fluorescence (XRF) Analyzer with Thermo Scientific X-ray tube and XRF assays were completed at select locations. The XRF was calibrated by the equipment supplier, and prior to each building’s survey, and was transported in accordance with applicable regulations. The scope of work for this survey did not include testing for airborne lead and/or lead in settled dust.

Page 4: ASBESTOS AND LEAD BUILDING SURVEY

3

The purpose of the lead survey was to determine in accessible areas the presence and general location of LBP in the interior and exterior of the subject buildings. These objectives were met by completing the following tasks:

x Perform a visual inspection for suspect LBP following U.S. Department of Housing and Urban Development (HUD) and California Department of Public Health (CDPH) guidelines;

x Test and analyze suspect material for lead content; and

x Prepare this report summarizing the inspection activities, findings, conclusions, and recommendations.

Page 5: ASBESTOS AND LEAD BUILDING SURVEY

4

2.0 SITE DESCRIPTION The subject site is comprised of three residential properties located at 1010, 1022, and 1050 N Twin Oaks Valley Road, San Marcos, California. The subject site is situated north of Interstate-78 and southwest of Interstate-15 in a residential area. 1010 N Twin Oaks Valley Road This property is comprised of a single-family home, trellis, carport, barn, shed, and a filled-in pool and was reportedly built in the 1880s and subsequently renovated. The house is 1,150 square feet, the barn is 1,632 square feet, and the shed is 608 square feet. The house is a one-story wooden structure with a crawlspace, attic, and asphalt shingle roof. The detached carport is a wooden structure with sheet metal roof. The property contains a wooden trellis between the house and carport. The exterior of the house contains wood siding, wood and metal window trim, and wood doors/doorframes. The house is comprised of a living room, dining room, kitchen, laundry room, three bedrooms, and two bathrooms. The flooring materials are sheet vinyl and carpet. The walls are drywall and joint compound and the ceiling has a sprayed-on acoustic texture on drywall. The barn is a two-story wooden structure with a sheet metal roof. The exterior of the barn contains wood siding, wood window trim, and wood doors/doorframes. The barn is comprised of an open area, bedroom, storage room, hay and tack room, two bathrooms, and a second floor room. The flooring materials are wood, sheet vinyl, concrete, and carpet. The walls are wood paneling, drywall, and joint compound and the ceiling is drywall or exposed wood beams. The shed is a one-story wooden structure with a sheet metal roof. The exterior of the shed contains wood siding, wood window trim, and wood door/door frame. The interior contains one room with wood walls and gravel floor. 1022 N Twin Oaks Valley Road This property is comprised of a 2,940 square foot single-family home with an attached garage, carport, and a pool. It was built in the 1970s and subsequently renovated. The house is a one-story wooden structure on concrete slab with an asphalt shingle roof. The exterior of the house contains stucco walls, wood window trim, and wood doors/door frames. The house is comprised of a living room, dining room, kitchen, four bedrooms, two bathrooms, and an unfinished two-car garage. The flooring materials are sheet vinyl, carpet, wood, and concrete. The walls are drywall and joint compound and the ceiling has a sprayed-on acoustic texture on drywall. 1050 N Twin Oaks Valley Road This property is comprised of a 2,015 square foot single-family home with an attached carport. It was built in the 1970s and subsequently renovated. The house is a one-story wooden structure on concrete slab with an asphalt shingle roof. The exterior of the house contains stucco walls, wood window trim, and wood doors/door frames.

Page 6: ASBESTOS AND LEAD BUILDING SURVEY

5

The house is comprised of a living room, dining room, kitchen, laundry room, three bedrooms, and two bathrooms. The flooring materials are wood, carpet, and sheet vinyl. The walls and ceilings are a combination of drywall, joint compound, and plaster.

Page 7: ASBESTOS AND LEAD BUILDING SURVEY

6

3.0 ASBESTOS BACKGROUND AND SURVEY METHODOLOGY 3.1 Asbestos Background and Regulations Background Asbestos is a group of naturally occurring mineral fibers. Due to its durability and insulating quality, it was used in a wide variety of building products including structural fireproofing, pipe and duct insulation, plasters, roofing, floor tile, and vinyl floor sheeting. Adverse health effects have been associated with the inhalation of airborne asbestos fibers by asbestos industry workers. The asbestos fibers that are tightly bound in building materials do not represent an exposure hazard unless disturbed in such a way that airborne fibers release (i.e., cutting, drilling, or sanding). By June of 1978, the U.S. Environmental Protection Agency (EPA) had effectively banned the use of asbestos in spray application products such as structural fireproofing and acoustic ceilings, pipe-lagging, joint compounds, and spackles. Asbestos is still used in the manufacture of non-friable products such as vinyl floor tile and roofing materials. Regulations In accordance with the EPA's National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation and the San Diego Air Pollution Control District (SDAPCD), all facilities planned for renovation or demolition must be surveyed for ACM prior to the planned renovation or demolition. Subsequent abatement or encapsulation of identified ACMs is also required. Abatement requires removal to the greatest extent practical, preferably complete removal, disposal, and replacement, if necessary, of the ACM. Removal may require encapsulation of the structure, or portions throughout, to lock down or control residual fibers which may exist. Regulatory agencies and municipal building agencies typically require removal of all ACMs prior to demolition or renovation. ACMs include friable ACMs; Category I non-friable ACMs, which have or will become friable or that have been subjected to sanding, drilling, grinding, cutting, or abrading; and Category II non-friable ACMs that may become or have become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation. ACCM will be removed as Category I or II ACM. Special regulations apply to the handling, transportation, and disposal of ACCM*. The following is a summary of current state and federal regulations containing requirements related to the performance of building surveys for asbestos. These summaries are not intended to be all inclusive and do not contain every aspect of the regulations discussed. *Regulations pertaining to the removal and disposal of ACMs are not included in this report. National Emission Standards for Hazardous Air Pollutants Under NESHAP, 40 CFR Part 61, regulation, no visible emissions are allowed during building demolition or renovation activities which involve regulated asbestos-containing materials (RACMs). For this reason, all buildings must be surveyed for ACMs prior to demolition or renovation. The EPA and/or the local air quality management district, which implements EPA actions, must be notified prior to any building demolition even if no ACMs are present. RACM is defined as any material with an asbestos content of greater than one percent and is friable, or

Page 8: ASBESTOS AND LEAD BUILDING SURVEY

7

Category I non-friable ACM that has or will become friable, or Category II non-friable ACM that may become or will become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation.

According to NESHAP, ACM is material containing more than one percent (1.0%) asbestos as determined using the methods specified in 40 CFR Part 763, Appendix A, Subpart E, Section 1, Polarized Light Microscopy (PLM). NESHAP classifies ACM as friable or non-friable. Friable ACM is ACM that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Non-friable ACM is further classified as either Category I ACM or Category II ACM. The materials are distinguished by their potential to release fibers when damaged. Category I ACM includes asbestos-containing gaskets, packings, resilient floor coverings and mastics, and asphalt roofing products. Asphalt roofing products include built-up roofing, asphalt-containing membrane systems, asphalt shingles, asphalt-containing underlayment felts, asphalt-containing roof coatings and mastics, and asphalt-containing base flashings. Category II ACM includes all other non-friable ACM, such as asbestos cement shingles, asbestos cement tiles, and asbestos cement boards or panels. Category II ACMs are much more likely to release fibers when damaged. If a material is analyzed as <1.0% asbestos through PLM analysis, it must be, at a minimum, 400-point counted to confirm it is less than 1.0% asbestos. Until the material is point counted, it must be considered ACM. San Diego Air Pollution Control District The SDAPCD is a government agency that regulates sources of air pollution within San Diego County to protect public health. The SDAPCD’s regulating and enforcement authority comes from state law and, in certain cases, federal law. In response to the NESHAP requirements, SDAPCD implemented Rule 351.145 and 1206 (adopted November 15, 2017) that pertains to demolition/renovation activities including the removal and associated disturbance of ACMs. These requirements for demolition and renovation activities include notification, ACM removal procedures, time schedules, ACM handling and cleanup procedures, storage, disposal, and landfill requirements for asbestos-containing waste materials. Rule 351.145 and 1206 are applicable to owners and operators of any demolition or renovation activity and associated disturbance of ACMs. Failure to comply with requirements could result in violations that carry daily penalties (penalties assessment is based upon the size of the project and severity of noncompliance).

Asbestos Hazard Emergency Response Act AHERA is a federal regulation requiring performance of asbestos surveys and the development of Asbestos Management Plans for all of the nation's primary and secondary schools. The general procedures mandated under AHERA are considered the industry standard and are used as a guideline for all surveys performed by Threshold. California Occupational Safety and Health Administration Per California Occupational Safety and Health Administration (Cal-OSHA) standard Title 8 CCR 1529, ACMs are defined as any materials with an asbestos content greater than one percent (>1.0%). Work involving contact, disturbance, or removal of ACMs is classified as Class I, Class

Page 9: ASBESTOS AND LEAD BUILDING SURVEY

8

II, Class III, or Class IV work. The work classes are based upon the risk level of exposure. Cal-OSHA prescribes specific engineering controls and work practices for each Class of ACM as follows:

x Class I This Class refers to ACMs identified as Thermal System Insulation (TSI) or surfacing (sprayed-on or troweled-on) materials. These materials are generally considered friable.

x Class II This Class refers to ACMs identified that are not TSI or surfacing materials. These materials are generally considered non-friable.

x Class III This Class refers to repair and maintenance operations of all identified ACMs.

x Class IV This Class refers to incidental contact with ACMs such as work including custodial staff.

Cal-OSHA defines asbestos-containing construction material (ACCM), for the purpose of worker protection, as material containing greater than one tenth of one percent (>0.1%) asbestos by weight. Material that is greater than 0.1% but less than 1.0% asbestos is not considered hazardous asbestos waste and can be disposed of as regular construction material. For material to be confirmed as ACCM and not ACM, it must be, at a minimum, 400-point counted to verify the sample is less than 1.0% asbestos. For material to be confirmed as less than 0.1% asbestos, it must be, at a minimum, 1,000-point counted. Cal-OSHA considers all TSI and surfacing materials installed prior to 1980 to be ACM unless proven otherwise. If these building materials are not sampled, they may be considered a presumed asbestos-containing material (PACM). California Health and Safety Code The California Health and Safety Code 25915 (former Connelly Bill) requires all building owners in the State of California to provide written notification to employees, tenants, and contractors of the known presence and location of ACMs/ACCMs within their buildings. Some exclusions to the notification rule for restricted access areas are allowed. All documentation related to asbestos surveys (and air monitoring) must be made available to employees, tenants, or contractors for review. The California Health and Safety Code defines ACCMs as:

Asbestos materials with less than 1.0%, but greater that 0.10% asbestos. These ACMs require an abatement plan during demolition that is protective of worker health and safety. However, unlike an EPA classified ACM, ACCMs do not necessitate special disposal requirements.

The California Health and Safety Code also requires that a seller with any knowledge of ACMs/ACCMs on a property disclose such information or knowledge to other parties involved in a real estate transaction. 3.2 Asbestos Survey Methodology Bulk Sampling for Asbestos In February 2021, the subject buildings were visually inspected and suspect asbestos materials were sampled in accordance with the methods presented in the Federal AHERA regulations (40

Page 10: ASBESTOS AND LEAD BUILDING SURVEY

9

CFR, Part 763) as a guideline. Identified suspect materials were also physically assessed for friability, condition, and disturbance factors. Threshold personnel collected a total of 114 representative suspect bulk asbestos samples from accessible areas of the interior and exterior of the subject buildings. The building’s materials appeared to be homogenous within specific areas and were sampled accordingly. The following is a list of the materials that were targeted: x Window putty x Mortar x Grout x Caulk x Spray-on acoustic ceiling x Drywall/joint compound x Sheet vinyl x Vapor barrier

x Wall insulation x Wire insulation x Roof assembly x Roof penetration mastic x Expansion foam x Plaster x Stucco

Bulk samples of suspect materials were collected to determine the asbestos content. The analytical results identify the percentage of each type of asbestos detected. AHERA sample criteria guidelines were followed to determine the appropriate number of samples collected per homogenous materials. Samples approximately one-half square inch in size were collected of each suspect material. Each sample was collected by removing the material using a sharp instrument to cut away a representative piece. The sample of suspect material was placed in a plastic bag and quickly sealed to prevent material escape or the introduction of contamination from outside sources. A unique sample number was assigned to each sample. In conducting the survey, Threshold personnel did not collect samples in hidden materials such as internal wiring between walls and floors in the buildings. Additionally, it is a widely accepted practice, and Threshold’s recommendation, to collect additional bulk samples during actual removal/abatement activities if hidden suspect ACMs are discovered. Additional suspect materials discovered during removal/renovation activities that are not sampled and analyzed must be presumed to be ACM. Asbestos Laboratory Testing Threshold submitted the collected building material samples under legal chain-of-custody to Eurofins. Samples were analyzed for Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and EPA 600/M4-82/020 Methods using Polarized Light Microscopy (PLM). Eurofins is an accredited laboratory, accredited under the National Institute of Standards and Technology's National Voluntary Laboratory Accreditation Program (NVLAP Lab Code #101768-0). The PLM analysis is a visual estimation only. The lower limit of reliable detection (quantifiable) for asbestos using the PLM method is approximately one-percent (1.0%) by volume. Since PLM methodology cannot quantify the exact percentage of asbestos detected less than one-percent, it would identify these materials as <1.0%. Only materials containing no asbestos fibers are identified as “None Detected.”

Page 11: ASBESTOS AND LEAD BUILDING SURVEY

10

4.0 ASBESTOS SURVEY RESULTS

4.1 Confirmed Asbestos-Containing Materials ACMs were detected in the samples collected and analyzed from two of the three residences: 1010 and 1022 N Twin Oaks Valley Drive. Of the samples collected, eight (8) were determined to be ACM. One building material was determined to be PACM. No ACMs were detected in the samples collected and analyzed from 1050 N Twin Oaks Valley Drive. The following list provides a description and location of identified ACMs and PACM within the subject buildings: 1010 N Twin Oaks Valley Drive

x Black roof penetration mastic (ACM) – 150 ft2. Located on the roof of the house, all roof seams and penetrations.

x Wire coating (PACM) – 12 each. Located in the attic of the house. 1022 N Twin Oaks Valley Drive

x White spray-on acoustic ceiling (ACM) – 1,000 ft2. Located on the ceiling throughout the house.

x Grey caulk and putty (ACM) – 100 ft2. Located on exterior windows of the house. x Tan sheet vinyl (ACM) – 25 ft2. Located in the garage under the water heater.

Bulk material samples were collected from representative homogeneous materials throughout the interior, exterior, and roof of the buildings. The sample locations are shown on the attached figures (Figures 1-4, and 6). The summary of ACM and PACM are provided in Table 1. Photographs of representative material samples determined to be ACM and PACM are provided on the Asbestos Photograph Record. The asbestos analytical laboratory reports are attached (Appendix B). The ACM and PACM identified in the subject buildings were generally in good condition, with the exception of the tan sheet vinyl being damaged. The identified materials will require removal prior to renovation/demolition activities, which would disturb them, in accordance with the EPA NESHAP, Cal-OSHA, and the local SDAPCD.

4.2 Non-ACMs or Non-Suspect Materials The following materials were observed in the building and were either not suspect-ACMs (and not sampled) or were sampled during this survey and no asbestos was detected. This is not meant as a complete listing of non-ACM building materials observed within the structure, but provided to indicate that these materials were considered.

Page 12: ASBESTOS AND LEAD BUILDING SURVEY

11

These materials include:

x Materials not considered part of the building (e.g., shelves)

x Glass and windows

x Plastic

x Metal x Fabric x Mortar x Grout x Drywall/joint

compound x Vapor barrier

x Wall insulation x Wire insulation x Roof assembly x Expansion foam x Plaster x Stucco

Page 13: ASBESTOS AND LEAD BUILDING SURVEY

12

5.0 LEAD BACKGROUND AND SURVEY METHODOLGY 5.1 Lead Background and Regulations Background

Lead is a bluish-gray, non-combustible metal that occurs naturally in the earth’s crust. Lead is malleable, ductile, and resistant to corrosion. These basic properties led to the use of lead, historically, as a paint additive. Lead is a highly toxic metal that was used for many years in products found in and around residential and commercial buildings. Lead may cause a range of health effects, from behavioral problems and learning disabilities, to seizures and death. Children six years old and under are most at risk due to the developmental stage of their bodies. The primary sources of lead exposure, based on research, include deteriorating lead-based paint in buildings, lead contaminated soil, and lead contaminated dust.

In pre-1955 paint, lead comprised 25% to 75% of the paint’s contents. In 2009, the Consumer Product Safety Commission (CPSC) ruled that consumer paint could not contain more than 0.009% lead.

Regulations U.S. Environmental Protection Agency, Toxic Substances Control Act, Section 403 The federal lead-based paint standard is defined as paint or other surface coatings containing lead at or above 1.0 mg/cm2, 0.5% by weight, or 5,000 parts per million (ppm). U.S. Department of Housing and Urban Development Residential lead inspections follow HUD Guidelines for the Evaluation and Control of Lead-based Paint in Housing (HUD Guidelines). HUD Guidelines include sampling methodology, LBP inspection requirements, and abatement requirements. ASTM E 1729, Standard Practice for Field Collection of Dried Paint Samples for Subsequent Lead Determination American Society for Testing and Materials (ASTM) E 1729 contains standard practice recommendations for inspectors to follow while collecting paint chip samples. California Occupational Safety and Health Administration Cal-OSHA Title 8, CCR Section 1532.1 details requirements for employees who may be exposed to lead during construction work including, but not limited to, demolition of structures where LBP is present, removal of LBP materials, and transportation and disposal of LBP. 5.2 Lead Survey Methodology Sampling for Lead

In February 2021, Threshold conducted screening for LBP on accessible interior and exterior building components utilizing an XRF. A total of 231 lead assay measurements were recorded

Page 14: ASBESTOS AND LEAD BUILDING SURVEY

13

throughout the interior and exterior of the subject buildings to determine lead concentrations. Threshold conducted sampling of building materials that are representative of the possible LBP materials in a building. XRF testing of building components was performed on randomly selected painted, stained, coated and/or varnished surfaces in general accordance with the Lead-Based Paint Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing, Chapter 7: Lead-Based Paint Inspection, 1997 Revision.

XRF Analysis

The XRF measurement procedure is an industry-accepted practice commonly utilized when many analyses are required, non-destructive techniques are preferred, and/or when immediate results are desired. During the lead inspection, Threshold may not conduct lead testing in every room and/or sample every painted/varnished/coated/stained building component. However, all similar building materials (i.e., same color, substrate, etc.) are grouped together and considered positive or negative in conjunction with the building materials that were sampled.

XRF results are identified as positive, negative, or inconclusive based on Performance Characteristic Sheets (PCS), developed by HUD and EPA for each model of XRF device that is commercially available. “Positive” refers to XRF results greater than or equal to the threshold. “Negative” refers to XRF results less than the threshold. The Federal Guidelines recommend classifying XRF results to the 1.0 mg/cm2 standard whenever possible, therefore:

“Positive” refers to XRF results greater than or equal to 1.0 mg/cm2 lead

“Negative” refers to XRF results less than 1.0 mg/cm2lead

“Inconclusive” refers to XRF results that could not be verified as Positive or Negative. To err on the side of caution, all Inconclusive XRF results are considered Positive.

XRF values are collected by placing the scanner on the test surface and exposing the lead paint film to gamma radiation. XRF analyzers are usually capable of penetrating up to 25 layers of paint to determine lead content. At the conclusion of each test, the shutter is closed and the display on the control console depicts the lead concentration in mg/cm2 for manual tabulation or, in some cases, stores sampling information in sequence in a data logger, which can be transferred to a computer for sorting and report generation.

Sampling procedures were based on HUD Guidelines. In accordance with these Guidelines, and to better organize sampling data, the four sides of each building were designated as A, B, C, and D. “Side A” is designated as the wall the building’s address is located – generally the front wall of the building. The naming continues in a clockwise motion with “Side B,” “Side C,” and “Side D.”

The HUD Guidelines define the surfaces to be tested as “testing combinations,” which are comprised of a room, building component, and substrate. The testing location is a specific area on a testing combination. Each test with the XRF is called an “assay” or “shot.”

Page 15: ASBESTOS AND LEAD BUILDING SURVEY

14

6.0 LEAD SURVEY RESULTS 6.1 Survey Results for Lead-Based Paint and Lead-Containing Surfaces Of the 231 lead assays, 10 were above the regulatory limit for lead. LBP/LCS materials were detected in buildings on all three properties. A positive result on one component triggers a positive result for that material throughout the structure. The following list provides a description and location of identified LBP/LCS within the subject buildings by XRF sampling: 1010 N Twin Oaks Valley Drive

x Trellis: Red wood trellis – 175 ft2. Located on the exterior of the house. x Barn: Multi-colored floor tile – 6 ft2. Located on the exterior of the barn. x Barn: White wood columns– 1,500 ft2 total for all white painted wood. Located on the

exterior of the barn* x Barn: Red wood door – 4,500 ft2 total for all red painted wood. Located on the exterior of

the barn* x Barn: White wood columns – 1,500 ft2 total for all white painted wood. Located in the

barn tack hay* x *All interior and exterior white and red paint on wood surfaces of barn is considered

LBP.

1022 N Twin Oaks Valley Drive x White shower tile – 100 ft2. Located in the restroom shower. x White wood ceiling beams – 300 ft2. Located in the garage.

1050 N Twin Oaks Valley Drive

x White tile – 50 ft2. Located on the kitchen walls. The sample locations are shown on the attached figures (Figures 1-3, 5, and 6). A summary of LBP materials is provided in Table 2. The full list of the XRF lead sample log and material descriptions is provided as Appendix C. The completed and signed CDPH 8552 Lead Hazard Evaluation Report forms are attached as Appendix D. Photographs of representative material samples identified during the subject property survey as LBP are provided on the Lead Photograph Record.

Page 16: ASBESTOS AND LEAD BUILDING SURVEY

15

7.0 CONCLUSIONS ACM, PACM, LBP, and LCS were detected in the subject buildings based on observations, laboratory analysis results, and field instrument measurements. 7.1 Asbestos Survey Results ACMs were detected in the samples collected and analyzed from two of the three residences: 1010 and 1022 N Twin Oaks Valley Drive. Of the samples collected, eight (8) were determined to be ACM. One building material was determined to be PACM. No ACMs were detected in the samples collected and analyzed from 1050 N Twin Oaks Valley Drive. The following list provides a description and location of identified ACMs and PACM within the subject buildings: 1010 N Twin Oaks Valley Drive

x Black roof penetration mastic (ACM) – 150 ft2. Located on the roof of the house, all roof seams and penetrations.

x Wire coating (PACM) – 12 each. Located in the attic of the house. 1022 N Twin Oaks Valley Drive

x White spray-on acoustic ceiling (ACM) – 1,000 ft2. Located on the ceiling throughout the house.

x Grey caulk and putty (ACM) – 100 ft2. Located on exterior windows of the house. x Tan sheet vinyl (ACM) – 25 ft2. Located in the garage under the water heater.

7.2 Lead Survey Results LBP/LCS was detected by XRF readings within all three residences. The following list provides a description and location of identified LBP/LCS within the subject buildings by XRF: 1010 N Twin Oaks Valley Drive

x Trellis: Red wood trellis – 175 ft2. Located on the exterior of the house* x Barn: Multi-colored floor tile – 6 ft2. Located on the exterior of the barn. x Barn: White wood columns– 1,500 ft2 total for all white painted wood. Located on the

exterior of the barn* x Barn: Red wood door – 4,500 ft2 total for all red painted wood. Located on the exterior of

the barn* x Barn: White wood columns – 1,500 ft2 total for all white painted wood. Located in the

barn tack hay* x *All interior and exterior white and red paint on wood surfaces of barn is considered

LBP.

1022 N Twin Oaks Valley Drive x White shower tile – 100 ft2. Located in the restroom shower. x White wood ceiling beams – 300 ft2. Located in the garage.

Page 17: ASBESTOS AND LEAD BUILDING SURVEY

16

1050 N Twin Oaks Valley Drive x White tile – 50 ft2. Located on the kitchen walls.

Page 18: ASBESTOS AND LEAD BUILDING SURVEY

17

8.0 RECOMMENDATIONS Threshold recommends that, prior to renovation activities, Threshold designate/mark the suspect and confirmed ACM, PACM, or LBP materials prior to the contractor pre-bid site inspection. Furthermore, only licensed abatement firms should be contracted to remove identified ACM and LBP materials. If additional suspect materials are uncovered during renovations that are not listed in this report, they should be assumed positive and handled accordingly until additional testing is performed. Threshold also recommends abatement contractors confirm the hazardous material quantities during a pre-bid job walk prior to bidding. This document is a guidance document and, because all material could not be accessed, should not be considered a bidding document. Contractors should be asked to provide a unit cost for abatement materials in the event more material is found than estimated. Cal-OSHA defines ACCM, for the purpose of worker protection, as material containing greater than one tenth of one percent (>0.1%) asbestos by weight. Material that is greater than 0.1% but less than 1.0% asbestos is not considered hazardous asbestos waste and can be disposed of as regular construction material. For material to be confirmed as ACCM and not ACM, it must be, at a minimum, 400-point counted to verify the sample is less than 1.0% asbestos. For material to be confirmed as less than 0.1% asbestos, it must be, at a minimum, 1,000-point counted. Therefore, until a point count is performed by a certified laboratory, the sprayed-on acoustic ceiling material must be considered ACM and treated as such.

Page 19: ASBESTOS AND LEAD BUILDING SURVEY

18

9.0 STATEMENT OF LIMITATIONS The conclusions and recommendations contained in this report/assessment are based upon professional opinions with regard to the subject matter. These opinions have been arrived at in accordance with currently accepted standards and practices applicable to this location and are subject to the following inherent limitations:

x The material estimates provided herein are gross estimates of materials based on observations made, analyses performed, and opinions of qualified expert professionals.

x The data and findings presented in this report are valid as of the dates when the investigations were performed. The passage of time, manifestation of latent conditions, or occurrence of future events may require further exploration at the site, analysis of the data, and reevaluation of the findings, observations, and conclusions expressed in the report.

x The data reported and the findings, observations, and recommendations expressed in the

report are limited by the Scope of Work.

x Unless otherwise stated in the report, because of the limitations stated above, the findings observations, and recommendations expressed by Threshold in this report are not, and should not be, considered an opinion concerning the compliance of any past or present owner or operator of the site with any federal, state or local law or regulation.

x No warranty or guarantee, whether express or implied, is made with respect to the data or

the reported findings, observations, and conclusions, all of which, however, accurately reflect site conditions in existence at the time of investigation.

x Threshold reports present professional opinions and findings of a scientific and technical

nature. While attempts were made to relate the data and findings to applicable environmental laws and regulations, the report shall not be construed to offer legal opinion as to the requirements of, nor compliance with, environmental laws, rules, regulations or policies of federal, state or local governmental agencies. Any use constitutes acceptance of the limits of Threshold’s liability. Threshold’s liability extends only to those parties contracted to complete this project and not to any other parties who may obtain the Report. Issues raised by the report should be reviewed by appropriate legal counsel.

Page 20: ASBESTOS AND LEAD BUILDING SURVEY

FIGURES

Page 21: ASBESTOS AND LEAD BUILDING SURVEY

FIGURE 1

HOUSE 1010 ASBESTOS AND LEAD XRFSAMPLE LOCATIONS MAP

1010 N. TWIN OAKS VALLEY ROADSAN MARCOS, CA

LIVING ROOMCARPET

DINING ROOM KITCHEN BATH#2

BEDROOM#3

ATTIC ENTRY

BEDROOM#1

BEDROOM#2

MASTERBATHROOM

#1

LAUNDRY

SLID

ERW

INDO

W

005

038

003

004

CRAWLSPACEACCESS

001

007

006

002

008

BRICK 019020

021

024

026025

031

028

038 027

014

017

023

010

011

015 022

009012

016

033

029

030

032

013

HOUSE

CARPORT

BARN

NORTH

LEGENDEXTERIOR ASBESTOS SAMPLE INTERIOR ASBESTOS SAMPLEROOF ASBESTOS SAMPLEINTERIOR ASBESTOS SAMPLE

NOTE: NO LEAD DETECTED IN HOUSE

25’

46’

SHED

PROPERTY MAP KEY

lhundrup
(ATTIC)
Page 22: ASBESTOS AND LEAD BUILDING SURVEY

FIGURE 2

BARN 1010 ASBESTOS AND LEADSAMPLE LOCATIONS MAP

1010 N. TWIN OAKS VALLEY ROADSAN MARCOS, CA

HOUSE

CARPORT

BARN

SHED

NORTH

LEGENDEXTERIOR ASBESTOS SAMPLEINTERIOR ASBESTOS SAMPLEPOSITIVE LEAD SAMPLE

OPEN ROOM

STORAGEROOM

HAY & TACKREEM

CLOSET

BEDROOM

STAIRSBATHROOM

039036

039

041

215 LBP COLUMNS BEAMS WHITE

186 LBP BARN SWING DOOR

184 EXT COLUMN WHITE

042

OPEN ROOM

035

034

037

040BATH

STAIRS

OPEN ROOM(USED AS ART STUDIO)

044043

183 LCS TILE MULTICOLOR

1ST FLOOR

2ND FLOOR

48’

34’

PROPERTY MAP KEY

NOTE: NO ASBESTOS DETECTED IN BARN

Page 23: ASBESTOS AND LEAD BUILDING SURVEY

FIGURE 3

BARN, SHED & POOL 1010 ACM/LEADSAMPLE LOCATIONS MAP

1010 N. TWIN OAKS VALLEY ROADSAN MARCOS, CA

HOUSE

CARPORT

BARN

NORTH

16’48’

38’

SHED

SHIPPINGCONTAINER

1 STORY ON A SLABWOODEN STRUCTURESHEET METAL ROOF

2 STORIESON SLABWOODEN STRUCTURESHEET METAL ROOF

BARN

047

046

045

041

186 LBP BARN SWING DOOR RED

183 LCS TILE FLOOR

CARPORTWOODEN STRUCTURESHEET METAL ROOF

184 LBP EXTERIOR BARN COLUMN WHITE

174 LBP TRELLACE RED

HOUSE1 STORY WITH ATTIC

ON SLABWOODEN STRUCTURE

ASPHALT SHINGLE ROOF(SEE OTHER FIGURE HOUSE)

LEGENDEXTERIOR ASBESTOS SAMPLEINTERIOR ASBESTOS SAMPLEPOSITIVE LEAD XRF SAMPLE

34’

SHED

PROPERTY MAP KEY

POOL(NO LEAD)

lhundrup
174 TRELLIS WOOD RED
Page 24: ASBESTOS AND LEAD BUILDING SURVEY

HOUSE

NORTHEXTERIOR ASBESTOS SAMPLE INTERIOR ASBESTOS SAMPLEROOF ASBESTOS SAMPLE

POOL

PROPERTY MAP KEY

LEGEND

FIGURE 4

HOUSE 1022 ASBESTOSSAMPLE LOCATIONS MAP

1022 N. TWIN OAKS VALLEY ROADSAN MARCOS, CA

NOTE: SEE FIGURE 5 FOR LEAD

105’

27’

BEDROOM#3

BEDROOM#4

BATH#2

KITCHEN

DININGROOM

GARAGE

LIVINGROOM

BATH#1

BEDROOM#2

BEDROOM#1

017

016

021018

022023

020026

024025

015

014

029

033

028

032034

031

034

030

027

009

PLAST 003

013012

037

ACCM 004

006007

019034/035 RPM ROOF SEAM

001

005

036

008

010 SOAC

012 ACCM SOAC

011 ACCM SOAC

Page 25: ASBESTOS AND LEAD BUILDING SURVEY

FIGURE 5

HOUSE & POOL 1022 POSITIVE LEADSAMPLE LOCATIONS MAP

1022 N. TWIN OAKS VALLEY ROADSAN MARCOS, CA

NOTE: NO LEAD DETECTED IN POOL

HOUSE

NORTH POSITIVE LEAD SAMPLE

FILLED IN POOL

PROPERTY MAP KEY

LEGEND

105’

27’

110 LCS SHOWER TILE WHITE

ON SLABWOODEN, STUCCO EXT.ASPHALT SHINGLE ROOF

HOUSE

FILLED IN(NO LEAD DETECTED)

POOL

130 LBP GARAGE WHITE BEAMS

Page 26: ASBESTOS AND LEAD BUILDING SURVEY

FIGURE 6

HOUSE 1050 ASBESTOS AND LEADSAMPLE LOCATIONS MAP

1050 N. TWIN OAKS VALLEY ROADSAN MARCOS, CA

HOUSE

NORTH

LEGENDEXTERIOR ASBESTOS SAMPLE INTERIOR ASBESTOS SAMPLEROOF ASBESTOS SAMPLEPOSITIVE LEAD SAMPLE

PROPERTY MAP KEY

005008002001

003

007

006

004

010

019

011

016

015

017

009SVF 024

014

013

012

023

023

026

027

018

020

022

021

060 LCSKITCHEN WALL TILE

ON SLABWOODEN, STUCCO EXT.ASPHALT ROOF

HOUSE

BEDROOM#3

BATH#1

KITCHEN

BEDROOM#2

BEDROOM#1

LIVINGROOM

DININGROOM

BEDROOM#4

SHED

CARPORT ROOF ONLY)

SHED(LAUNDRY)

32’

65’

BATH#2

lhundrup
NO ASBESTOS DETECTED IN HOUSE
Page 27: ASBESTOS AND LEAD BUILDING SURVEY

TABLES

Page 28: ASBESTOS AND LEAD BUILDING SURVEY

BUILDING MATERIAL DESCRIPTION GENERAL MATERIAL LOCATION* ANALYTICAL RESULTS ESTIMATED QUANTITY**

NESHAP RACM

CATEGORYCONDITION

1010 Black roof penetration mastic

Roof of house, all roof seams and penetrations 10% CH 150 ft2

Category I Non-

FriableGood

1010 Wire coating Throughout attic PACM 12 eachCategory II

Non-Friable

Good

1022 White spray-on acoustic ceiling Ceiling in house, throughout <1% CH 1,000 ft2

RACM, Friable Good

1022 Grey caulk and putty Exterior windows of house 2% CH 100 ft2Category II

Non-Friable

Good

1022 Tan sheet vinyl Garage, under water heater 5% CH 25 ft2Category I

Non-Friable

Damaged

Notes:CH = Chrysotile NESHAP = National Emission Standards for Hazardous Air PollutantsPACM = Presumed Asbestos-Containing Material RACM = Regulated Asbestos-Containing Materialft2 = Square feet* = Material locations are based on visible and accessible areas. It should be noted, materials may be present or discovered during demolition activities within interstitial wall/ceiling cavities or additional flooring layers may be discovered. ** = Quantities are estimates of building materials reported with asbestos. Quantities are estimates only and may not reflect accurate square footages.

Condition Definitions: Good is <5% damage, Damaged is 5% to 25% local area damage or 5% to <10% general damage, and Significantly Damaged is >25% local area damage or >10% general damage.

ACM threshold is any material containing greater than or equal to 1.0% asbestosCalifornia ACCM threshold is any material containing greater than or equal to 0.1% asbestos

TABLE 1SUMMARY OF ASBESTOS-CONTAINING MATERIALS

Residential Properties1010 and 1022 N Twin Oaks Valley Road

San Marcos, CA

Page 29: ASBESTOS AND LEAD BUILDING SURVEY

BUILDING ROOM COMPONENT SUBSTRATE COLORPb

(mg/cm2)QUANTITY CONDITION

1010 House Exterior Trellis Wood Red 4.16 175 ft2 Intact1010 Barn Exterior Floor Tile Multi 12.8 6 ft2 Intact

1010 Barn Exterior Column Wood White 8.03

1,500 ft2 (total for all interior/exterior

white paint on wood in barn)

Intact

1010 Barn Exterior Door Wood Red 1.54

4,500 ft2 (total for all interior/exterior red paint on wood

in barn)

Intact

1010 Barn Tack Hay Column Wood White 2.06

1,500 ft2 (total for all interior/exterior

white paint on wood in barn)

Intact

1022 Restroom 1 Shower Tile Tile White 7.14 100 ft2 Intact1022 Garage Ceiling Beam Wood White 1.02 - 1.63 300 ft2 Intact1050 Kitchen Wall Tile White 9.24 50 ft2 Intact

Notes:Pb = Leadmg/cm2 = milligram per square centimeterft2 = square feet

LBP threshold is material containing greater than or equal to 1.0 mg/cm 2

TABLE 2SUMMARY OF LEAD-BASED PAINT MATERIALS

Residential Properties1010, 1022, and 1050 N Twin Oaks Valley Road

San Marcos, CA

Page 30: ASBESTOS AND LEAD BUILDING SURVEY

PHOTOGRAPHS

Page 31: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROASBESTOS PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 2 of 8

1010 N Twin Oaks Valley Road - black roof penetration mastic on roof (ACM)

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 1 of 8

1010 N Twin Oaks Valley Road - exterior of the house

Page 32: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROASBESTOS PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 4 of 8

1022 N Twin Oaks Valley Road - exterior of the house

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 3 of 8

1010 N Twin Oaks Valley Road - Wire coating in attic (PACM)

Page 33: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROASBESTOS PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 6 of 8

1022 N Twin Oaks Valley Road - grey caulk and putty on exterior windows of house (ACM)

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 5 of 8

1022 N Twin Oaks Valley Road - white spray-on acoustic ceiling, throughout house (ACM)

Page 34: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROASBESTOS PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 8 of 8

1050 N Twin Oaks Valley Road - exterior of the house; no ACMs detected

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 7 of 8

1022 N Twin Oaks Valley Road - tan sheet vinyl in garage, under water heater (ACM)

Page 35: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROLEAD PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 2 of 8

1010 N Twin Oaks Valley Road - multi-colored floor tile on exterior of barn

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 1 of 8

1010 N Twin Oaks Valley Road - red wood trellis on exterior of house

Page 36: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROLEAD PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 4 of 8

1010 N Twin Oaks Valley Road - red wood door on exterior of barn (all red paint on wood)

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 3 of 8

1010 N Twin Oaks Valley Road - white wood columns on exterior of barn (all white paint on wood)

Page 37: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROLEAD PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 6 of 8

1022 N Twin Oaks Valley Road - white shower tile in restroom

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 5 of 8

1010 N Twin Oaks Valley Road - white wood columns in barn tack hay (all white paint on wood)

Page 38: ASBESTOS AND LEAD BUILDING SURVEY

THRESHOLD ENVIROLEAD PHOTOGRAPHIC RECORD

Client: Tetra Tech, Inc. Job Number: 210216 TET-NTOVR Survey

Photographer: Gavin Seedorf and Dylan Gerard Date: February 2021

Photograph 8 of 8

1050 N Twin Oaks Valley Road - white tile on kitchen walls

Site Name: Residential Properties Location: 1010, 1022, and 1050N Twin Oaks Valley RoadSan Marcos, CA 92069

Photograph 7 of 8

1010 N Twin Oaks Valley Road - white wood ceiling beams in garage

Page 39: ASBESTOS AND LEAD BUILDING SURVEY

APPENDIX A

PERSONNEL CERTIFICATIONS

Page 40: ASBESTOS AND LEAD BUILDING SURVEY
Page 41: ASBESTOS AND LEAD BUILDING SURVEY
Page 42: ASBESTOS AND LEAD BUILDING SURVEY

APPENDIX B

ANALYTICAL LABORATORY REPORTS AND CHAIN-OF-CUSTODY

DOCUMENTATIONS

Page 43: ASBESTOS AND LEAD BUILDING SURVEY

Approved by:

Approved SignatoryKyle Demsko

Report for:

Gavin SeedorfThreshold Enviro1053 Tourmaline StSan Diego, CA 92109

Regarding: Project: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley RoadEML ID: 2579975

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 02-24-2021

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)NVLAP Lab Code 500056-0

EMLab ID: 2579975, Page 1 of 13Eurofins EPK Built Environment Testing, LLC

Page 44: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTTotal Samples Submitted: 47Total Samples Analyzed: 47

Total Samples with Layer Asbestos Content > 1%: 1

Location: 1, Window Putty Lab ID-Version‡: 12304694-1

Sample Layers Asbestos ContentWhite Window Putty ND

Sample Composite Homogeneity: Good

Location: 2, Window Putty Lab ID-Version‡: 12304695-1

Sample Layers Asbestos ContentWhite Window Putty ND

Sample Composite Homogeneity: Good

Location: 3, Mortar Lab ID-Version‡: 12304696-1

Sample Layers Asbestos ContentGray Mortar ND

Sample Composite Homogeneity: Good

Location: 4, Mortar Lab ID-Version‡: 12304697-1

Sample Layers Asbestos ContentGray Mortar ND

Sample Composite Homogeneity: Good

EMLab ID: 2579975, Page 2 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 45: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 5, Mortar Lab ID-Version‡: 12304698-1

Sample Layers Asbestos ContentGray Mortar ND

Sample Composite Homogeneity: Good

Location: 6, Caulk Lab ID-Version‡: 12304699-1

Sample Layers Asbestos ContentRed Caulk ND

Sample Composite Homogeneity: Good

Location: 7, Caulk Lab ID-Version‡: 12304700-1

Sample Layers Asbestos ContentBrown Wood with Red Paint ND

Composite Non-Asbestos Content: 90% CelluloseSample Composite Homogeneity: Good

Location: 8a, Spray on Acoustic Lab ID-Version‡: 12304701-1

Sample Layers Asbestos ContentWhite Ceiling Texture with Paint ND

Sample Composite Homogeneity: Good

EMLab ID: 2579975, Page 3 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 46: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 9b, Spray on Acoustic Lab ID-Version‡: 12304702-1

Sample Layers Asbestos ContentWhite Ceiling Texture with Paint ND

Sample Composite Homogeneity: Good

Location: 10c, Spray on Acoustic Lab ID-Version‡: 12304703-1

Sample Layers Asbestos ContentWhite Ceiling Texture with Paint ND

Sample Composite Homogeneity: Good

Location: 11d, Spray on Acoustic Lab ID-Version‡: 12304704-1

Sample Layers Asbestos ContentWhite Ceiling Texture with Paint ND

Sample Composite Homogeneity: Good

Location: 12e, Spray on Acoustic Lab ID-Version‡: 12304705-1

Sample Layers Asbestos ContentWhite Ceiling Texture with Paint ND

Sample Composite Homogeneity: Good

EMLab ID: 2579975, Page 4 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 47: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 13, DW/JC Lab ID-Version‡: 12304706-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Joint Compound NDWhite Tape ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Poor

Location: 14, DW/JC Lab ID-Version‡: 12304707-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Poor

Location: 15, DW/JC Lab ID-Version‡: 12304708-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Poor

Location: 16, DW/JC Lab ID-Version‡: 12304709-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Joint Compound NDWhite Tape ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Poor

EMLab ID: 2579975, Page 5 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 48: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 17, DW/JC Lab ID-Version‡: 12304710-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Poor

Location: 18, DW/JC Lab ID-Version‡: 12304711-1

Sample Layers Asbestos ContentBrown Fibrous Material with Paint ND

Composite Non-Asbestos Content: 75% CelluloseSample Composite Homogeneity: Poor

Location: 19, Sheet Vinyl Lab ID-Version‡: 12304712-1

Sample Layers Asbestos ContentYellow Mastic ND

Tan Sheet Flooring with Fibrous Backing NDComposite Non-Asbestos Content: 20% Cellulose

5% Glass FibersSample Composite Homogeneity: Moderate

Location: 20, Sheet Vinyl Lab ID-Version‡: 12304713-1

Sample Layers Asbestos ContentYellow Mastic ND

Brown Sheet Flooring with Fibrous Backing NDComposite Non-Asbestos Content: 20% Cellulose

5% Glass FibersSample Composite Homogeneity: Moderate

EMLab ID: 2579975, Page 6 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 49: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 21, Sheet Vinyl Lab ID-Version‡: 12304714-1

Sample Layers Asbestos ContentYellow Mastic ND

Brown Sheet Flooring with Fibrous Backing NDComposite Non-Asbestos Content: 20% Cellulose

5% Glass FibersSample Composite Homogeneity: Moderate

Location: 22, SVF and Caulk Lab ID-Version‡: 12304715-1

Sample Layers Asbestos ContentWhite Caulk ND

Transparent Caulk NDYellow Mastic ND

Tan Sheet Flooring with Fibrous Backing NDComposite Non-Asbestos Content: 20% Cellulose

5% Glass FibersSample Composite Homogeneity: Moderate

Location: 23, Sheet Vinyl Lab ID-Version‡: 12304716-1

Sample Layers Asbestos ContentYellow Mastic ND

Tan Sheet Flooring with Fibrous Backing NDComposite Non-Asbestos Content: 20% Cellulose

5% Glass FibersSample Composite Homogeneity: Moderate

Location: 24, Vapor Barrier Lab ID-Version‡: 12304717-1

Sample Layers Asbestos ContentBlack Vapor Barrier ND

Composite Non-Asbestos Content: 85% CelluloseSample Composite Homogeneity: Good

EMLab ID: 2579975, Page 7 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 50: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 25, Insulation Lab ID-Version‡: 12304718-1

Sample Layers Asbestos ContentYellow Insulation ND

Composite Non-Asbestos Content: 95% Glass FibersSample Composite Homogeneity: Good

Location: 26, Wiring Insulation Lab ID-Version‡: 12304719-1

Sample Layers Asbestos ContentBlack Insulation ND

Composite Non-Asbestos Content: 35% CelluloseSample Composite Homogeneity: Good

Location: 27, Roof Assembly Lab ID-Version‡: 12304720-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Black Roofing Shingle with Gray Pebbles NDComposite Non-Asbestos Content: 60% CelluloseSample Composite Homogeneity: Good

Location: 28, Roof Assembly Lab ID-Version‡: 12304721-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Black Roofing Shingle with Gray Pebbles NDComposite Non-Asbestos Content: 60% CelluloseSample Composite Homogeneity: Good

EMLab ID: 2579975, Page 8 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 51: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 29, RA Lab ID-Version‡: 12304722-1

Sample Layers Asbestos ContentBlack Roofing Shingle with Pebbles ND

Sample Composite Homogeneity: Good

Location: 30, RA Lab ID-Version‡: 12304723-1

Sample Layers Asbestos ContentBlack Roofing Shingle with Pebbles ND

Sample Composite Homogeneity: Good

Location: 31, RA Lab ID-Version‡: 12304724-1

Sample Layers Asbestos ContentBlack Roofing Shingle with Pebbles ND

Sample Composite Homogeneity: Good

Location: 32, RPM Lab ID-Version‡: 12304725-1

Sample Layers Asbestos ContentBlack Roofing Mastic 10% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 2579975, Page 9 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

lhundrup
Page 52: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 33, RPM Lab ID-Version‡: 12304726-1

Sample Layers Asbestos ContentBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% Cellulose5% Glass Fibers

Sample Composite Homogeneity: Good

Location: 34, Window Putty Lab ID-Version‡: 12304727-1

Sample Layers Asbestos ContentGray Window Putty ND

Sample Composite Homogeneity: Good

Location: 35, Caulk Lab ID-Version‡: 12304728-1

Sample Layers Asbestos ContentWhite Caulk ND

Sample Composite Homogeneity: Good

Location: 36, Putty Lab ID-Version‡: 12304729-1

Sample Layers Asbestos ContentGray Window Putty ND

Sample Composite Homogeneity: Good

EMLab ID: 2579975, Page 10 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 53: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 37, Expansion Foam Lab ID-Version‡: 12304730-1

Sample Layers Asbestos ContentYellow Putty ND

Sample Composite Homogeneity: Good

Location: 38, RPM Lab ID-Version‡: 12304731-1

Sample Layers Asbestos ContentBlack Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Good

Location: 39, Putty Lab ID-Version‡: 12304732-1

Sample Layers Asbestos ContentGray Putty ND

Sample Composite Homogeneity: Good

Location: 40, Drywall and Joint CPD Lab ID-Version‡: 12304733-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Joint Compound NDCream Tape ND

White Texture with Paint NDComposite Non-Asbestos Content: 15% CelluloseSample Composite Homogeneity: Moderate

EMLab ID: 2579975, Page 11 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 54: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 41, DW JC Lab ID-Version‡: 12304734-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Moderate

Location: 42, DW JC Lab ID-Version‡: 12304735-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Moderate

Location: 43, DW JC Lab ID-Version‡: 12304736-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

White Texture with Paint NDComposite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Moderate

Location: 44, Sheet Vinyl Lab ID-Version‡: 12304737-1

Sample Layers Asbestos ContentTan Sheet Flooring with Fibrous Backing ND

Composite Non-Asbestos Content: 20% Cellulose5% Glass Fibers

Sample Composite Homogeneity: Good

EMLab ID: 2579975, Page 12 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 55: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K6100 Mountain Vista St, Ste #160, Henderson, NV 89014

(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1010; 1010 N Twin Oaks valley Road

Date of Sampling: 02-15-2021Date of Receipt: 02-19-2021Date of Report: 02-24-2021

ASBESTOS PLM REPORTLocation: 45, Putty Lab ID-Version‡: 12304738-1

Sample Layers Asbestos ContentGray Putty ND

Sample Composite Homogeneity: Good

Location: 46, Putty Lab ID-Version‡: 12304739-1

Sample Layers Asbestos ContentGray Putty ND

Sample Composite Homogeneity: Good

Location: 47, Putty Lab ID-Version‡: 12304740-1

Sample Layers Asbestos ContentGray Putty ND

Sample Composite Homogeneity: Good

EMLab ID: 2579975, Page 13 of 13Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 56: ASBESTOS AND LEAD BUILDING SURVEY
Page 57: ASBESTOS AND LEAD BUILDING SURVEY
Page 58: ASBESTOS AND LEAD BUILDING SURVEY
Page 59: ASBESTOS AND LEAD BUILDING SURVEY

Approved by:

Approved SignatoryBalu Krishnan

Report for:

Gavin SeedorfThreshold Enviro1053 Tourmaline StSan Diego, CA 92109

Regarding: Project: 210216 TOVR ACM 1022EML ID: 2579967

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 02-25-2021 and 03-01-2021

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 2579967, Page 1 of 11Eurofins EPK Built Environment Testing, LLC

Page 60: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTTotal Samples Submitted: 40Total Samples Analyzed: 40

Total Samples with Layer Asbestos Content > 1%: 4

Location: 1, Plaster Lab ID-Version‡: 12304794-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDSample Composite Homogeneity: Good

Location: 2, Plaster Lab ID-Version‡: 12304795-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDSample Composite Homogeneity: Good

Location: 3, Plaster Lab ID-Version‡: 12304796-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDSample Composite Homogeneity: Good

Location: 4, Plaster Lab ID-Version‡: 12304797-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDSample Composite Homogeneity: Good

EMLab ID: 2579967, Page 2 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 61: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 5, Plaster Lab ID-Version‡: 12304798-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDSample Composite Homogeneity: Good

Location: 6, Grout Lab ID-Version‡: 12304799-1

Sample Layers Asbestos ContentGray Grout ND

Sample Composite Homogeneity: Good

Location: 7, Grout Lab ID-Version‡: 12304800-1

Sample Layers Asbestos ContentGray Grout ND

Sample Composite Homogeneity: Good

Location: 8, Sheet Vinyl Lab ID-Version‡: 12304801-1

Sample Layers Asbestos ContentTan Sheet Flooring with Fibrous Backing ND

Composite Non-Asbestos Content: 20% Cellulose3% Glass Fibers

Sample Composite Homogeneity: Good

EMLab ID: 2579967, Page 3 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 62: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 9, Sheet Vinyl Lab ID-Version‡: 12304802-1

Sample Layers Asbestos ContentTan Sheet Flooring with Fibrous Backing ND

White Mastic NDComposite Non-Asbestos Content: 20% Cellulose

3% Glass FibersSample Composite Homogeneity: Good

Location: 10, SOAC Lab ID-Version‡: 12304803-1

Sample Layers Asbestos ContentWhite Ceiling Texture < 1% Chrysotile

Composite Non-Asbestos Content: 10% VermiculiteSample Composite Homogeneity: Good

Location: 11, SOAC Lab ID-Version‡: 12304804-1

Sample Layers Asbestos ContentWhite Ceiling Texture < 1% Chrysotile

Composite Non-Asbestos Content: 10% VermiculiteSample Composite Homogeneity: Good

Location: 12, SOAC Lab ID-Version‡: 12304805-1

Sample Layers Asbestos ContentWhite Ceiling Texture < 1% Chrysotile

Composite Non-Asbestos Content: 10% VermiculiteSample Composite Homogeneity: Good

EMLab ID: 2579967, Page 4 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 63: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 13, Insulation Lab ID-Version‡: 12304806-1

Sample Layers Asbestos ContentYellow Insulation ND

Composite Non-Asbestos Content: 95% Mineral WoolSample Composite Homogeneity: Good

Location: 14, Stucco Lab ID-Version‡: 12304807-1

Sample Layers Asbestos ContentGray Stucco with Paint ND

Sample Composite Homogeneity: Good

Location: 15, Stucco Lab ID-Version‡: 12304808-1

Sample Layers Asbestos ContentGray Stucco with Paint ND

Sample Composite Homogeneity: Good

Location: 16, Stucco Lab ID-Version‡: 12304809-1

Sample Layers Asbestos ContentGray Stucco with Paint ND

Sample Composite Homogeneity: Good

EMLab ID: 2579967, Page 5 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 64: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 17, Stucco Lab ID-Version‡: 12304810-1

Sample Layers Asbestos ContentGray Stucco with Paint ND

Sample Composite Homogeneity: Good

Location: 18, Grout Lab ID-Version‡: 12304811-1

Sample Layers Asbestos ContentGray Grout ND

Sample Composite Homogeneity: Good

Location: 19, Grout Lab ID-Version‡: 12304812-1

Sample Layers Asbestos ContentGray Grout ND

Sample Composite Homogeneity: Good

Location: 20, Grout Lab ID-Version‡: 12304813-1

Sample Layers Asbestos ContentGray Grout ND

Sample Composite Homogeneity: Good

EMLab ID: 2579967, Page 6 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 65: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 21, Brick Lab ID-Version‡: 12304814-1

Sample Layers Asbestos ContentRed Brick ND

Sample Composite Homogeneity: Good

Location: 22, Brick Lab ID-Version‡: 12304815-1

Sample Layers Asbestos ContentRed Brick ND

Sample Composite Homogeneity: Good

Location: 23, Brick Lab ID-Version‡: 12304816-1

Sample Layers Asbestos ContentRed Brick ND

Sample Composite Homogeneity: Good

Location: 24, Window Putty Lab ID-Version‡: 12304817-1

Sample Layers Asbestos ContentGray Putty 2% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 2579967, Page 7 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 66: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 25, Putty Lab ID-Version‡: 12304818-1

Sample Layers Asbestos ContentGray Putty 2% Chrysotile

Sample Composite Homogeneity: Good

Location: 26, Caulk and Putty Lab ID-Version‡: 12304819-1

Sample Layers Asbestos ContentGray Putty 2% ChrysotileGray Caulk 2% Chrysotile

Sample Composite Homogeneity: Good

Location: 27, Roof Assembly Lab ID-Version‡: 12304820-1

Sample Layers Asbestos ContentBlack Roofing Shingle /White Pebbles NDBlack Roofing Shingle /Black Pebbles ND

Black Tar Paper NDComposite Non-Asbestos Content: 40% Cellulose

20% Glass FibersSample Composite Homogeneity: Good

Location: 28, Roof Assembly Lab ID-Version‡: 12304821-1

Sample Layers Asbestos ContentBlack Roofing Shingle /White Pebbles ND

Black Roofing Shingle /Multicolored Pebbles NDBlack Tar Paper ND

Composite Non-Asbestos Content: 40% Cellulose20% Glass Fibers

Sample Composite Homogeneity: Good

EMLab ID: 2579967, Page 8 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 67: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 29, Roof Assembly Lab ID-Version‡: 12304822-1

Sample Layers Asbestos ContentBlack Roofing Shingle /White Pebbles ND

Black Roofing Shingle /Multicolored Pebbles NDBlack Tar Paper ND

Composite Non-Asbestos Content: 40% Cellulose20% Glass Fibers

Sample Composite Homogeneity: Good

Location: 30, RA Lab ID-Version‡: 12304823-1

Sample Layers Asbestos ContentBlack Roofing Shingle /Multicolored Pebbles ND

Black Roofing Material NDComposite Non-Asbestos Content: 15% Synthetic FibersSample Composite Homogeneity: Good

Location: 31, RPM Lab ID-Version‡: 12304824-1

Sample Layers Asbestos ContentBlack Roofing Mastic ND

Sample Composite Homogeneity: Good

Location: 32, RPM Lab ID-Version‡: 12304825-1

Sample Layers Asbestos ContentBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Good

EMLab ID: 2579967, Page 9 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 68: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 33, RPM Lab ID-Version‡: 12304826-1

Sample Layers Asbestos ContentBlack Sealant ND

Sample Composite Homogeneity: Good

Location: 34, RPM Lab ID-Version‡: 12304827-1

Sample Layers Asbestos ContentBlack Sealant ND

Sample Composite Homogeneity: Good

Location: 35, RPM Lab ID-Version‡: 12304828-1

Sample Layers Asbestos ContentBlack Sealant ND

Sample Composite Homogeneity: Good

Location: 36, Vinyl Lab ID-Version‡: 12304829-1

Sample Layers Asbestos ContentTan Floor Tile 5% ChrysotileYellow Mastic ND

Sample Composite Homogeneity: Good

EMLab ID: 2579967, Page 10 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 69: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1022

Date of Sampling: 02-17-2021Date of Receipt: 02-19-2021 and 02-25-2021Date of Report: 03-02-2021

ASBESTOS PLM REPORTLocation: 37, Vinyl Lab ID-Version‡: 12304830-1

Sample Layers Asbestos ContentTan Sheet Flooring with Fibrous Backing ND

Yellow Mastic NDComposite Non-Asbestos Content: 20% Cellulose

3% Glass FibersSample Composite Homogeneity: Good

Location: 37, Roof Assembly Lab ID-Version‡: 12327509-1

Sample Layers Asbestos ContentBlack Roofing Shingle ND

Black Roofing Tar and Felt NDBlack Roofing Material ND

Composite Non-Asbestos Content: 20% Glass FibersSample Composite Homogeneity: Poor

Location: 38, Roof Assembly Lab ID-Version‡: 12327510-1

Sample Layers Asbestos ContentBlack Roofing Shingle ND

Black Roofing Tar and Felt NDBlack Roofing Material ND

Composite Non-Asbestos Content: 20% Glass FibersSample Composite Homogeneity: Poor

Location: 39, Roof Penetration Mastic Lab ID-Version‡: 12327511-1

Sample Layers Asbestos ContentBlack Roofing Mastic ND

Sample Composite Homogeneity: Good

EMLab ID: 2579967, Page 11 of 11Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 70: ASBESTOS AND LEAD BUILDING SURVEY
lhundrup
001-040
Page 71: ASBESTOS AND LEAD BUILDING SURVEY
Page 72: ASBESTOS AND LEAD BUILDING SURVEY
Page 73: ASBESTOS AND LEAD BUILDING SURVEY

CHAIN OF CUSTODY

www.EMLabPK.com

New Jersey: 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 * (866) 871-1984 Phoenix, AZ: 1501 West Knudsen Drive, Phoenix, AZ 85027 * (800) 651-4802 SSF, CA: 6000 Shoreline Court, Suite 205, South San Francisco, CA 94080 * (866) 888-6653

CONTACT INFORMATION

Company: Address:

Contact: Special Instructions:

Phone:

PROJECT INFORMATION TURN AROUND TIME CODES (TAT)

Project ID: STD – Standard (DEFAULT) Rushes received after 2pm

or on weekends, will be considered received the next business day. Please alert us in advance of weekend

analysis needs.

Project Description: ND – Next Business Day

Project Zip Code: Sampling

Date & Time: SD – Same Business Day Rush*

PO Number: Sampled By: *Please call Client Services for locations with Rush services

Sample ID Description Sample Type (Below)

TAT (Above)

Total Volume (Air Samples only) Notes

By submitting this Chain of Custody, you agree to be bound by the terms and conditions set forth at http://www.emlab.com/terms-of-service Copyright © 2019 Eurofins EMLab P&K Asbestos COC, Doc. # EM-CS-F-8557, Rev 13. Revised 8/15/19, Page 1 of 1

ASBESTOS ANALYSIS

REQUESTED SERVICES (Check boxes below)

PCM Air

PLM Other Requests Bulk Rock &

Soil

Fibe

r Cou

nt (N

IOS

H 7

400)

OS

HA

with

TW

A

Asb

esto

s B

ulk

PLM

EP

A P

oint

Cou

nt (2

00 P

oint

Cou

nt)

EP

A P

oint

Cou

nt (4

00 P

oint

Cou

nt)

EP

A P

oint

Cou

nt (1

000

Poi

nt C

ount

)

Gra

vim

etric

Poi

nt C

ount

(400

Pt C

ount

)

Gra

vim

etric

Poi

nt C

ount

(100

0 Pt

Cou

nt)

CA

RB

435

Met

hod

(400

Poi

nt C

ount

)

CA

RB

435

Met

hod

(100

0 P

oint

Cou

nt)

Lead

Ana

lysi

s –

Flam

e A

A

SAMPLE TYPE CODES RELINQUISHED BY DATE & TIME RECEIVED BY DATE & TIME A – Air W – Wipe

B – Bulk T – Tape D – Dust R – Rock

SO – Soil O – Other:

lhundrup
Threshold Enviro
lhundrup
1053 Tourmaline St San Diego CA
lhundrup
Gavin Seedorf
lhundrup
858 688 3522
lhundrup
210216 TOVR ACM
lhundrup
Asbestos Bulk
lhundrup
lhundrup
lhundrup
lhundrup
lhundrup
lhundrup
lhundrup
- 1022
lhundrup
038 Ext Roof carport Center Roof assembly039 Ext Roof carport flat room Center Roof penetration mastic040 Ext Roof West Roof assembly
lhundrup
02.17.21
lhundrup
GS/ BF
lhundrup
02.25.21 12:00
lhundrup
please add to em lab project 2579967
Page 74: ASBESTOS AND LEAD BUILDING SURVEY

Approved by:

Approved SignatoryBalu Krishnan

Report for:

Gavin SeedorfThreshold Enviro1053 Tourmaline StSan Diego, CA 92109

Regarding: Project: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CAEML ID: 2579960

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 02-24-2021 and 02-25-2021

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)NVLAP Lab Code 200844-0

EMLab ID: 2579960, Page 1 of 8Eurofins EPK Built Environment Testing, LLC

Page 75: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CA

Date of Sampling: 02-18-2021Date of Receipt: 02-19-2021Date of Report: 02-25-2021

ASBESTOS PLM REPORTTotal Samples Submitted: 27Total Samples Analyzed: 27

Total Samples with Layer Asbestos Content > 1%: 0

Location: 1, Roof Assembly Lab ID-Version‡: 12304861-1

Sample Layers Asbestos ContentBlack Roofing Shingle /White Pebbles ND

Black Tar Paper NDComposite Non-Asbestos Content: 40% Cellulose

10% Glass FibersSample Composite Homogeneity: Good

Location: 2, Roof Assembly Lab ID-Version‡: 12304862-1

Sample Layers Asbestos ContentBlack Roofing Shingle /Black Pebbles NDBlack Roofing Shingle /White Pebbles ND

Black Roofing Shingle /Multicolored Pebbles NDComposite Non-Asbestos Content: 30% Cellulose

15% Glass FibersSample Composite Homogeneity: Good

Location: 3, Roof Assembly Lab ID-Version‡: 12304863-1

Sample Layers Asbestos ContentBlack Roofing Shingle /Multicolored Pebbles ND

Black Tar Paper NDComposite Non-Asbestos Content: 40% Cellulose

15% Glass FibersSample Composite Homogeneity: Good

Location: 4, Roof Assembly Lab ID-Version‡: 12304864-1

Sample Layers Asbestos ContentBlack Roofing Shingle /Multicolored Pebbles ND

Black Tar Paper NDComposite Non-Asbestos Content: 40% Cellulose

15% Glass FibersSample Composite Homogeneity: Good

EMLab ID: 2579960, Page 2 of 8Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 76: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CA

Date of Sampling: 02-18-2021Date of Receipt: 02-19-2021Date of Report: 02-25-2021

ASBESTOS PLM REPORTLocation: 5, Roof Assembly Lab ID-Version‡: 12304865-1

Sample Layers Asbestos ContentBlack Roofing Shingle /Multicolored Pebbles ND

Black Tar Paper NDComposite Non-Asbestos Content: 40% Cellulose

15% Glass FibersSample Composite Homogeneity: Good

Location: 6, RPM Lab ID-Version‡: 12304866-1

Sample Layers Asbestos ContentBlack Roofing Mastic ND

Sample Composite Homogeneity: Good

Location: 7, RPM Lab ID-Version‡: 12304867-1

Sample Layers Asbestos ContentBlack Roofing Mastic ND

Sample Composite Homogeneity: Good

Location: 8, RPM Lab ID-Version‡: 12304868-1

Sample Layers Asbestos ContentBlack Roofing Mastic ND

Sample Composite Homogeneity: Good

EMLab ID: 2579960, Page 3 of 8Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 77: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CA

Date of Sampling: 02-18-2021Date of Receipt: 02-19-2021Date of Report: 02-25-2021

ASBESTOS PLM REPORTLocation: 9, Stucco Lab ID-Version‡: 12304869-1

Sample Layers Asbestos ContentBeige Stucco with Paint ND

Sample Composite Homogeneity: Good

Location: 10, Stucco Lab ID-Version‡: 12304870-1

Sample Layers Asbestos ContentBeige Stucco with Paint ND

Sample Composite Homogeneity: Good

Location: 11, Stucco Lab ID-Version‡: 12304871-1

Sample Layers Asbestos ContentBeige Stucco with Paint ND

Sample Composite Homogeneity: Good

Location: 12, Stucco Lab ID-Version‡: 12304872-1

Sample Layers Asbestos ContentBeige Stucco with Paint ND

Sample Composite Homogeneity: Good

EMLab ID: 2579960, Page 4 of 8Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 78: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CA

Date of Sampling: 02-18-2021Date of Receipt: 02-19-2021Date of Report: 02-25-2021

ASBESTOS PLM REPORTLocation: 13, Stucco Lab ID-Version‡: 12304873-1

Sample Layers Asbestos ContentGray Stucco with Paint ND

Sample Composite Homogeneity: Good

Location: 14, Putty Lab ID-Version‡: 12304874-1

Sample Layers Asbestos ContentGray Putty ND

Sample Composite Homogeneity: Good

Location: 15, Putty Lab ID-Version‡: 12304875-1

Sample Layers Asbestos ContentGray Putty ND

Sample Composite Homogeneity: Good

Location: 16, Putty Lab ID-Version‡: 12304876-1

Sample Layers Asbestos ContentGray Putty ND

Sample Composite Homogeneity: Good

EMLab ID: 2579960, Page 5 of 8Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 79: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CA

Date of Sampling: 02-18-2021Date of Receipt: 02-19-2021Date of Report: 02-25-2021

ASBESTOS PLM REPORTLocation: 17, Plaster Lab ID-Version‡: 12304877-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDComposite Non-Asbestos Content: < 1% Hair/WoolSample Composite Homogeneity: Good

Location: 18, Plaster Lab ID-Version‡: 12304878-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDComposite Non-Asbestos Content: < 1% Hair/WoolSample Composite Homogeneity: Good

Location: 19, Plaster Lab ID-Version‡: 12304879-1

Sample Layers Asbestos ContentWhite Skim Coat with Paint ND

Gray Plaster NDComposite Non-Asbestos Content: < 1% Hair/WoolSample Composite Homogeneity: Good

Location: 20, Drywall and Joint Lab ID-Version‡: 12304880-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

Beige Tape NDWhite Joint Compound with Paint ND

Composite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Good

EMLab ID: 2579960, Page 6 of 8Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 80: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CA

Date of Sampling: 02-18-2021Date of Receipt: 02-19-2021Date of Report: 02-25-2021

ASBESTOS PLM REPORTLocation: 21, Drywall and Joint Lab ID-Version‡: 12304881-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

Beige Tape NDWhite Joint Compound with Paint ND

Composite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Good

Location: 22, Drywall and Joint Lab ID-Version‡: 12304882-1

Sample Layers Asbestos ContentWhite Drywall with Brown Paper ND

Beige Tape NDWhite Joint Compound with Paint ND

Composite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Good

Location: 23, Vinyl Lab ID-Version‡: 12304883-1

Sample Layers Asbestos ContentMulticolored Sheet Flooring with Fibrous Backing ND

White Mastic NDComposite Non-Asbestos Content: 20% Cellulose

3% Glass FibersSample Composite Homogeneity: Good

Location: 24, Vinyl Lab ID-Version‡: 12304884-1

Sample Layers Asbestos ContentWhite Sheet Flooring with Fibrous Backing ND

White Mastic NDComposite Non-Asbestos Content: 20% CelluloseSample Composite Homogeneity: Good

EMLab ID: 2579960, Page 7 of 8Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 81: ASBESTOS AND LEAD BUILDING SURVEY

Eurofins EMLab P&K3000 Lincoln Drive East, Suite A, Marlton, NJ 08053

(866) 871-1984 Fax (856) 334-1040 www.emlab.comClient: Threshold EnviroC/O: Gavin SeedorfRe: 210216 TOVR ACM 1050; 1050 N Twin Oaks Valley Rd San Marcos, CA

Date of Sampling: 02-18-2021Date of Receipt: 02-19-2021Date of Report: 02-25-2021

ASBESTOS PLM REPORTLocation: 25, Vinyl Lab ID-Version‡: 12304885-1

Sample Layers Asbestos ContentWhite Sheet Flooring with Fibrous Backing ND

White Mastic NDComposite Non-Asbestos Content: 20% CelluloseSample Composite Homogeneity: Good

Location: 26, Insulation Lab ID-Version‡: 12304886-1

Sample Layers Asbestos ContentYellow Insulation ND

Composite Non-Asbestos Content: 95% Mineral WoolSample Composite Homogeneity: Good

Location: 27, Insulation Lab ID-Version‡: 12304887-1

Sample Layers Asbestos ContentPink Insulation ND

Composite Non-Asbestos Content: 95% Mineral WoolSample Composite Homogeneity: Good

EMLab ID: 2579960, Page 8 of 8Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 82: ASBESTOS AND LEAD BUILDING SURVEY
Page 83: ASBESTOS AND LEAD BUILDING SURVEY
Page 84: ASBESTOS AND LEAD BUILDING SURVEY
Page 85: ASBESTOS AND LEAD BUILDING SURVEY

APPENDIX C

XRF DATA

Page 86: ASBESTOS AND LEAD BUILDING SURVEY

Assay No Time Site Structure Room Component Substrate Side Condition Color Pb Units Results Action LevelDuration13 2/17/21 19:14 Calibration CAL SRM SRM SRM A N/A RED 1.18 mg / cm ^2 Positive 1 2.1114 2/17/21 19:15 Calibration CAL SRM SRM SRM A N/A BEIGE 0.72 mg / cm ^2 Negative 1 1.6515 2/17/21 19:15 Calibration CAL SRM SRM CAL SRM A N/A YELLOW3.58 mg / cm ^2 Positive 1 0.4816 2/17/21 19:16 Calibration CAL SRM SRM CAL SRM A N/A ORGE 1.67 mg / cm ^2 Positive 1 0.8317 2/17/21 19:16 Calibration CAL SRM SRM CAL SRM A N/A GREEN <LOD mg / cm ^2 Negative 1 0.1518 2/17/21 19:17 Calibration CAL SRM SRM CAL SRM A N/A RED 1.21 mg / cm ^2 Positive 1 2.0119 2/17/21 19:17 Calibration CAL SRM SRM CAL SRM A N/A RED <LOD mg / cm ^2 Negative 1 0.1520 2/17/21 19:17 Calibration CAL SRM SRM CAL SRM A N/A RED 1.17 mg / cm ^2 Positive 1 2.3521 2/17/21 19:18 Calibration CAL SRM SRM CAL SRM A N/A RED 1.05 mg / cm ^2 Inconclusive1 49.2922 2/17/21 19:19 Calibration CAL SRM SRM CAL SRM A N/A RED 1.23 mg / cm ^2 Positive 1 2.1123 2/17/21 19:19 Calibration CAL SRM SRM CAL SRM A N/A RED 1.19 mg / cm ^2 Positive 1 2.124 2/18/21 10:14 1050 NTOVR CAL SRM SRM START CAL N/A N/A N/A RED 1.16 mg / cm ^2 Positive 1 6.8225 2/18/21 10:14 1050 NTOVR CAL SRM SRM START CAL N/A N/A N/A RED 1.02 mg / cm ^2 Inconclusive1 23.7626 2/18/21 10:15 1050 NTOVR CAL SRM SRM START CAL N/A N/A N/A RED 1.05 mg / cm ^2 Inconclusive1 20.7927 2/18/21 10:18 1050 NTOVR HOME EXT FIREPLACE WOOD A INTACT RED <LOD mg / cm ^2 Negative 1 2.7428 2/18/21 10:19 1050 NTOVR HOME EXT DOOR F WOOD A INTACT RED <LOD mg / cm ^2 Negative 1 3.4629 2/18/21 10:19 1050 NTOVR HOME EXT WALL PLASTER A INTACT RED <LOD mg / cm ^2 Negative 1 3.9230 2/18/21 10:19 1050 NTOVR HOME EXT WALL PLASTER B INTACT RED <LOD mg / cm ^2 Negative 1 4.2231 2/18/21 10:20 1050 NTOVR HOME EXT EAVES WOOD B INTACT RED <LOD mg / cm ^2 Negative 1 2.8832 2/18/21 10:21 1050 NTOVR HOME EXT CARPORT COLMN WOOD B INTACT BEIGE <LOD mg / cm ^2 Negative 1 3.5233 2/18/21 10:21 1050 NTOVR HOME EXT CARPORT WINDOW WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.434 2/18/21 10:22 1050 NTOVR HOME EXT CARPORT DOWNSPT WOOD B INTACT BROWN <LOD mg / cm ^2 Negative 1 3.1835 2/18/21 10:22 1050 NTOVR HOME EXT CARPORT DOOR SECURITYMETAL B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.6336 2/18/21 10:23 1050 NTOVR HOME EXT CARPORT CEILING METAL B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.0737 2/18/21 10:24 1050 NTOVR HOME EXT LAUNDY DOOR WOOD C INTACT RED <LOD mg / cm ^2 Negative 1 3.138 2/18/21 10:24 1050 NTOVR HOME EXT LAUNDY DOOR F WOOD C INTACT RED <LOD mg / cm ^2 Negative 1 3.1139 2/18/21 10:27 1050 NTOVR HOME EXT LAUNDY WALL PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 3.1840 2/18/21 10:28 1050 NTOVR HOME EXT LAUNDY CABINET WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 3.5341 2/18/21 10:29 1050 NTOVR HOME EXT LAUNDY CABINET WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 0.4942 2/18/21 10:30 1050 NTOVR HOME EXT LAUNDY CABINET WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 0.8443 2/18/21 10:31 1050 NTOVR HOME LIVG RM DOOR WOOD A INTACT RED <LOD mg / cm ^2 Negative 1 1.5844 2/18/21 10:31 1050 NTOVR HOME LIVG RM WALL PLASTER A INTACT WHITE 0.07 mg / cm ^2 Negative 1 3.1545 2/18/21 10:32 1050 NTOVR HOME LIVG RM WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.5846 2/18/21 10:32 1050 NTOVR HOME LIVG RM DOOR F WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.7547 2/18/21 10:33 1050 NTOVR HOME BR 1 DOOR F WOOD C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.6748 2/18/21 10:33 1050 NTOVR HOME BR 1 WALL PLASTER D INTACT WHITE 0.11 mg / cm ^2 Negative 1 1.5449 2/18/21 10:34 1050 NTOVR HOME BR 2 WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.5750 2/18/21 10:34 1050 NTOVR HOME BR 2 WALL PLASTER D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.6551 2/18/21 10:34 1050 NTOVR HOME BR 2 DOOR CLOSET PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.5952 2/18/21 10:35 1050 NTOVR HOME BR 2 CEILG PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.6553 2/18/21 10:35 1050 NTOVR HOME HALL CABINET WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 3.14

�1

Page 87: ASBESTOS AND LEAD BUILDING SURVEY

54 2/18/21 10:36 1050 NTOVR HOME BR 3 WALL PLASTER C INTACT WHITE 0.17 mg / cm ^2 Negative 1 3.2155 2/18/21 10:37 1050 NTOVR HOME RR 1 WALL PLASTER B INTACT WHITE 0.03 mg / cm ^2 Negative 1 1.2956 2/18/21 10:37 1050 NTOVR HOME RR 1 SHOWR PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 3.2557 2/18/21 10:37 1050 NTOVR HOME RR 1 FLOOR VINYL C INTACT BROWN <LOD mg / cm ^2 Negative 1 1.4258 2/18/21 10:38 1050 NTOVR HOME RR 1 TOILET PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.6859 2/18/21 10:38 1050 NTOVR HOME KITCH WALL PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.5960 2/18/21 10:39 1050 NTOVR HOME KITCH WALL TILE C INTACT WHITE 9.24 mg / cm ^2 Positive 1 3.8861 2/18/21 10:41 1050 NTOVR HOME KITCH CABINET WOOD C INTACT BEIGE <LOD mg / cm ^2 Negative 1 1.6962 2/18/21 10:41 1050 NTOVR HOME KITCH CABINET LOW WOOD C INTACT BEIGE <LOD mg / cm ^2 Negative 1 1.6263 2/18/21 10:43 1050 NTOVR HOME RR2 SINK PLASTER C INTACT BEIGE <LOD mg / cm ^2 Negative 1 1.6864 2/18/21 10:43 1050 NTOVR HOME RR2 FLOOR VINYL C INTACT BEIGE <LOD mg / cm ^2 Negative 1 1.5765 2/18/21 10:44 1050 NTOVR HOME BR4 DOOR WOOD C INTACT GREEN <LOD mg / cm ^2 Negative 1 1.5466 2/18/21 10:44 1050 NTOVR HOME BR4 WALL PLASTER C INTACT GREEN <LOD mg / cm ^2 Negative 1 1.5667 2/18/21 10:45 1050 NTOVR HOME BR4 FLOOR TILE C INTACT RED 0.02 mg / cm ^2 Negative 1 2.4668 2/18/21 11:11 1022 NTOVR CAL SRM SRM CAL N/A N/A N/A RED 1 mg / cm ^2 Inconclusive1 11.1769 2/18/21 11:12 1022 NTOVR CAL SRM SRM CAL N/A N/A N/A RED 1.04 mg / cm ^2 Inconclusive1 10.3670 2/18/21 11:12 1022 NTOVR CAL SRM SRM CAL N/A N/A N/A RED 1.05 mg / cm ^2 Inconclusive1 21.9971 2/18/21 11:14 1022 NTOVR HOME EXT DOOR F WOOD A INTACT BEIGE 0.03 mg / cm ^2 Negative 1 1.7672 2/18/21 11:14 1022 NTOVR HOME EXT DOOR F GARAG METAL A INTACT BEIGE <LOD mg / cm ^2 Negative 1 3.2673 2/18/21 11:15 1022 NTOVR HOME EXT WALL WOOD A INTACT BEIGE <LOD mg / cm ^2 Negative 1 3.5574 2/18/21 11:15 1022 NTOVR HOME EXT OVRHANG WOOD A INTACT GRY 0.06 mg / cm ^2 Negative 1 1.5975 2/18/21 11:16 1022 NTOVR HOME EXT OVRHANG WOOD A INTACT BEIGE 0.06 mg / cm ^2 Negative 1 1.5676 2/18/21 11:16 1022 NTOVR HOME EXT OVRHANG WOOD A INTACT BROWN 0.03 mg / cm ^2 Negative 1 3.1777 2/18/21 11:16 1022 NTOVR HOME EXT WINDOW WOOD A INTACT GRY 0.18 mg / cm ^2 Negative 1 3.7878 2/18/21 11:17 1022 NTOVR HOME EXT POOL TILE WOOD A INTACT BLUE <LOD mg / cm ^2 Negative 1 3.5479 2/18/21 11:18 1022 NTOVR HOME EXT POOL TILE WOOD A INTACT BLUE <LOD mg / cm ^2 Negative 1 3.4380 2/18/21 11:19 1022 NTOVR HOME EXT TILE SPANISH WOOD C INTACT RED 0.63 mg / cm ^2 Negative 1 5.8281 2/18/21 11:19 1022 NTOVR HOME EXT TILE SPANISH WOOD C INTACT RED 0.69 mg / cm ^2 Negative 1 5.7882 2/18/21 11:20 1022 NTOVR HOME EXT WINDOW WOOD C INTACT GRY <LOD mg / cm ^2 Negative 1 3.2783 2/18/21 11:20 1022 NTOVR HOME EXT SPPORT BEAM PORCH WOOD C INTACT GRY <LOD mg / cm ^2 Negative 1 1.5584 2/18/21 11:21 1022 NTOVR HOME EXT DOOR BACK WOOD C INTACT BEIGE <LOD mg / cm ^2 Negative 1 3.3285 2/18/21 11:21 1022 NTOVR HOME EXT DOOR BACK FRM WOOD C INTACT BEIGE <LOD mg / cm ^2 Negative 1 3.1686 2/18/21 11:22 1022 NTOVR HOME EXT CARPORTCEILING WOOD B INTACT BEIGE 0.05 mg / cm ^2 Negative 1 1.4687 2/18/21 11:24 1022 NTOVR HOME LVNG RM DOOR WOOD B INTACT BROWN <LOD mg / cm ^2 Negative 1 1.6688 2/18/21 11:24 1022 NTOVR HOME LVNG RM DOOR F WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 2.3489 2/18/21 11:25 1022 NTOVR HOME LVNG RM WINDOW WOOD A INTACT WHITE 0.02 mg / cm ^2 Negative 1 3.0990 2/18/21 11:25 1022 NTOVR HOME LVNG RM BEAM CEILIG WOOD A INTACT WHITE 0.02 mg / cm ^2 Negative 1 2.4591 2/18/21 11:26 1022 NTOVR HOME LVNG RM WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 2.1792 2/18/21 11:26 1022 NTOVR HOME HALL WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.2893 2/18/21 11:26 1022 NTOVR HOME HALL DOOR WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.56

Assay No Time Site Structure Room Component Substrate Side Condition Color Pb Units Results Action LevelDuration

�2

Page 88: ASBESTOS AND LEAD BUILDING SURVEY

94 2/18/21 11:26 1022 NTOVR HOME HALL DOOR WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.6395 2/18/21 11:26 1022 NTOVR HOME HALL DOOR WOOD C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.6996 2/18/21 11:27 1022 NTOVR HOME HALL WALL PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 0.9697 2/18/21 11:27 1022 NTOVR HOME HALL WALL PLASTER D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.5798 2/18/21 11:27 1022 NTOVR HOME HALL WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.6699 2/18/21 11:27 1022 NTOVR HOME HALL WALL PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.56

100 2/18/21 11:28 1022 NTOVR HOME HALL CABINET WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.56101 2/18/21 11:28 1022 NTOVR HOME BR 1 WALL PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 0.88102 2/18/21 11:28 1022 NTOVR HOME BR 1 WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.2103 2/18/21 11:29 1022 NTOVR HOME BR 1 WINDOW PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.39104 2/18/21 11:29 1022 NTOVR HOME BR 1 WINDOW PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.66105 2/18/21 11:30 1022 NTOVR HOME BR 2 FIREPLACE WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.24106 2/18/21 11:30 1022 NTOVR HOME BR 2 DOOR WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.21107 2/18/21 11:30 1022 NTOVR HOME BR 2 WINDOW PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 3.17108 2/18/21 11:31 1022 NTOVR HOME RR 1 DOOR WOOD C INTACT WHITE 0.05 mg / cm ^2 Negative 1 1.24109 2/18/21 11:31 1022 NTOVR HOME RR 1 FLOOR WOOD C INTACT BLUE <LOD mg / cm ^2 Negative 1 1.39110 2/18/21 11:32 1022 NTOVR HOME RR 1 SHOWER TILE WOOD C INTACT WHITE 7.14 mg / cm ^2 Positive 1 2.13111 2/18/21 11:34 1022 NTOVR HOME RR 1 SINK PLASTER D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.57112 2/18/21 11:34 1022 NTOVR HOME RR 1 CABINET WOOD D INTACT WHITE 0.03 mg / cm ^2 Negative 1 1.2113 2/18/21 11:34 1022 NTOVR HOME RR 1 TOIL WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 0.84114 2/18/21 11:40 1022 NTOVR HOME KITCHN WALL WOOD D INTACT BROWN <LOD mg / cm ^2 Negative 1 1.19115 2/18/21 11:41 1022 NTOVR HOME KITCHN FLOOR VINYL D INTACT BEIGE <LOD mg / cm ^2 Negative 1 1.4116 2/18/21 11:41 1022 NTOVR HOME HALL EAST CABINET WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.34117 2/18/21 11:42 1022 NTOVR HOME BR 4 DOOR WOOD C INTACT BROWN <LOD mg / cm ^2 Negative 1 1.52118 2/18/21 11:43 1022 NTOVR HOME BR 4 DOOR F WOOD C INTACT WHITE 0.03 mg / cm ^2 Negative 1 1.3119 2/18/21 11:43 1022 NTOVR HOME BR 4 WALL PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.58120 2/18/21 11:43 1022 NTOVR HOME BR 4 WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.26121 2/18/21 11:43 1022 NTOVR HOME BR 4 WALL PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 3.5122 2/18/21 11:44 1022 NTOVR HOME BR 4 WALL PLASTER D INTACT WHITE <LOD mg / cm ^2 Negative 1 3.05123 2/18/21 11:44 1022 NTOVR HOME GARAGE DOOR WOOD LEFT INTACT BROWN <LOD mg / cm ^2 Negative 1 3.08124 2/18/21 11:45 1022 NTOVR HOME GARAGE WALL PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.22125 2/18/21 11:46 1022 NTOVR HOME GARAGE WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.53126 2/18/21 11:46 1022 NTOVR HOME GARAGE CABINET WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.23127 2/18/21 11:47 1022 NTOVR HOME GARAGE BEAM WOOD CEILING INTACT WHITE <LOD mg / cm ^2 Negative 1 1.66128 2/18/21 11:47 1022 NTOVR HOME GARAGE BEAM WOOD CEILING INTACT WHITE <LOD mg / cm ^2 Negative 1 1.3129 2/18/21 11:57 1022 NTOVR HOME GARAGE BEAM WOOD CEILING INTACT WHITE 1.02 mg / cm ^2 Inconclusive1 8.83130 2/18/21 11:57 1022 NTOVR HOME GARAGE BEAM WOOD CEILING INTACT WHITE 1.63 mg / cm ^2 Positive 1 7.1131 2/18/21 11:57 1022 NTOVR HOME GARAGE BEAM WOOD CEILING INTACT WHITE 1.04 mg / cm ^2 Inconclusive1 21.17132 2/18/21 11:59 1010 NTOVR CAL SRM SRM N/A N/A N/A RED 1.3 mg / cm ^2 Positive 1 2.5133 2/18/21 11:59 1010 NTOVR CAL SRM SRM N/A N/A N/A RED 0.91 mg / cm ^2 Inconclusive1 1.56

Assay No Time Site Structure Room Component Substrate Side Condition Color Pb Units Results Action LevelDuration

�3

Page 89: ASBESTOS AND LEAD BUILDING SURVEY

134 2/18/21 11:59 1010 NTOVR CAL SRM SRM N/A N/A N/A RED 1.16 mg / cm ^2 Positive 1 5.17135 2/18/21 12:02 1010 NTOVR HOME LIVING ROOM DOOR WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.3136 2/18/21 12:02 1010 NTOVR HOME LIVING ROOM DOOR F WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.18137 2/18/21 12:03 1010 NTOVR HOME LIVING ROOM WALL PLASTER B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.55138 2/18/21 12:03 1010 NTOVR HOME LIVING ROOM WALL DRYWALL B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.33139 2/18/21 12:03 1010 NTOVR HOME LIVING ROOM WALL DRYWALL A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.27140 2/18/21 12:04 1010 NTOVR HOME LIVING ROOM WINDOW DRYWALL A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.31141 2/18/21 12:04 1010 NTOVR HOME LIVING ROOM WINDOW DRYWALL C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.19142 2/18/21 12:04 1010 NTOVR HOME LIVING ROOM WINDOW DRYWALL D INTACT WHITE <LOD mg / cm ^2 Negative 1 3.17143 2/18/21 12:05 1010 NTOVR HOME KITCH CABINET WOOD C INTACT WHITE 0.18 mg / cm ^2 Negative 1 0.96144 2/18/21 12:05 1010 NTOVR HOME KITCH CABINET COUNTR WOOD C INTACT BEIGE <LOD mg / cm ^2 Negative 1 0.95145 2/18/21 12:05 1010 NTOVR HOME KITCH FLOOR VINYL C INTACT BEIGE <LOD mg / cm ^2 Negative 1 3.14146 2/18/21 12:06 1010 NTOVR HOME LNDRY SHLV WOOD A INTACT BEIGE 0.67 mg / cm ^2 Negative 1 3.65147 2/18/21 12:07 1010 NTOVR HOME LNDRY WALL DRYWALL B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.18148 2/18/21 12:43 1010 NTOVR HOME HALL WALL DRYWALL A INTACT WHITE <LOD mg / cm ^2 Negative 1 0.84149 2/18/21 12:44 1010 NTOVR HOME HALL WALL DRYWALL C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.39150 2/18/21 12:44 1010 NTOVR HOME HALL DOOR WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.67151 2/18/21 12:44 1010 NTOVR HOME HALL DOOR F WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.63152 2/18/21 12:45 1010 NTOVR HOME BR 1 WALL WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.19153 2/18/21 12:45 1010 NTOVR HOME BR 2 WALL METAL A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.28154 2/18/21 12:45 1010 NTOVR HOME BR 2 WALL METAL B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.32155 2/18/21 12:46 1010 NTOVR HOME BA 1 WALL DRYWALL A INTACT WHITE <LOD mg / cm ^2 Negative 1 0.85156 2/18/21 12:46 1010 NTOVR HOME BA 1 WALL DRYWALL C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.3157 2/18/21 12:47 1010 NTOVR HOME BR 2 WINDOW WOOD C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.54158 2/18/21 12:48 1010 NTOVR HOME BA 2 WALL METAL A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.29159 2/18/21 12:48 1010 NTOVR HOME BA 2 WALL METAL B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.17160 2/18/21 12:49 1010 NTOVR HOME BA 2 SHOWR PLAST B INTACT BEIGE <LOD mg / cm ^2 Negative 1 0.95161 2/18/21 12:49 1010 NTOVR HOME BA 2 FLOOR VINYL B INTACT BEIGE <LOD mg / cm ^2 Negative 1 0.87162 2/18/21 12:49 1010 NTOVR HOME BA 2 DOOR WOOD B INTACT BEIGE <LOD mg / cm ^2 Negative 1 0.95163 2/18/21 12:50 1010 NTOVR HOME BA 2 DOOR F WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.31164 2/18/21 12:50 1010 NTOVR HOME BA 2 CABINET WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 0.86165 2/18/21 12:51 1010 NTOVR HOME EXT DOOR SECURITY METAL B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.65166 2/18/21 12:52 1010 NTOVR HOME EXT DR FRM WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.2167 2/18/21 12:52 1010 NTOVR HOME EXT WALL WOOD B INTACT RED <LOD mg / cm ^2 Negative 1 1.25168 2/18/21 12:52 1010 NTOVR HOME EXT WINDOW WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 3.26169 2/18/21 12:53 1010 NTOVR HOME EXT DOWNSPT METAL B INTACT RED <LOD mg / cm ^2 Negative 1 1.17170 2/18/21 12:53 1010 NTOVR HOME EXT WALL WOOD C INTACT RED <LOD mg / cm ^2 Negative 1 1.18171 2/18/21 12:54 1010 NTOVR HOME EXT WALL WOOD D INTACT RED <LOD mg / cm ^2 Negative 1 1.2172 2/18/21 12:54 1010 NTOVR HOME EXT DOOR SLIDER WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 0.87173 2/18/21 12:54 1010 NTOVR HOME EXT OVERHANG WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.19

Assay No Time Site Structure Room Component Substrate Side Condition Color Pb Units Results Action LevelDuration

�4

Page 90: ASBESTOS AND LEAD BUILDING SURVEY

174 2/18/21 12:55 1010 NTOVR HOME EXT LATTICE WOOD D INTACT RED 4.16 mg / cm ^2 Positive 1 4.02175 2/18/21 12:57 1010 NTOVR HOME EXT STAIR PLASTER D INTACT BLUE <LOD mg / cm ^2 Negative 1 1.22176 2/18/21 12:58 1010 NTOVR POOL EXT TILE 2x2 PLASTER D INTACT BLUE <LOD mg / cm ^2 Negative 1 0.88177 2/18/21 12:59 1010 NTOVR POOL EXT TILE 2x2 PLASTER D INTACT BLUE <LOD mg / cm ^2 Negative 1 0.85178 2/18/21 13:01 1010 NTOVR BARN EXT WALL WOOD A INTACT RED <LOD mg / cm ^2 Negative 1 1.56179 2/18/21 13:01 1010 NTOVR BARN EXT DOOR WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 3.26180 2/18/21 13:01 1010 NTOVR BARN EXT CABINET WOOD A INTACT RED <LOD mg / cm ^2 Negative 1 1.55181 2/18/21 13:02 1010 NTOVR BARN EXT FLASHING GROUND METAL A INTACT RED <LOD mg / cm ^2 Negative 1 2.49182 2/18/21 13:02 1010 NTOVR BARN EXT WINDOW WOOD B INTACT WHITE 0.02 mg / cm ^2 Negative 1 3.19183 2/18/21 13:03 1010 NTOVR BARN EXT FLOOR TILE B INTACT MULTI 12.8 mg / cm ^2 Positive 1 1.34184 2/18/21 13:05 1010 NTOVR BARN EXT COLUMN WOOD C INTACT WHITE 8.03 mg / cm ^2 Positive 1 3.53185 2/18/21 13:07 1010 NTOVR BARN EXT EAVE WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 3.18186 2/18/21 13:08 1010 NTOVR BARN EXT DOOR WOOD A INTACT RED 1.54 mg / cm ^2 Positive 1 1.66187 2/18/21 13:09 1010 NTOVR BARN EXT DOOR F WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.54188 2/18/21 13:09 1010 NTOVR BARN EXT DOOR F WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.43189 2/18/21 13:11 1010 NTOVR BARN ENTRY NORTHEASTDOOR F WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.67190 2/18/21 13:11 1010 NTOVR BARN ENTRY NORTHEASTDOOR F WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.35191 2/18/21 13:11 1010 NTOVR BARN ENTRY NORTHEASTDOOR F DRYWALL C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.31192 2/18/21 13:12 1010 NTOVR BARN RR DOOR F WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.19193 2/18/21 13:12 1010 NTOVR BARN RR DOOR WOOD D INTACT WHITE 0.07 mg / cm ^2 Negative 1 1.29194 2/18/21 13:12 1010 NTOVR BARN RR TOIL PLASTER D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.78195 2/18/21 13:13 1010 NTOVR BARN RR CEILING WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.29196 2/18/21 13:13 1010 NTOVR BARN RR CABINET WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.19197 2/18/21 13:13 1010 NTOVR BARN RR SHOWER PLASTIC B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.34198 2/18/21 13:14 1010 NTOVR BARN BACK DOOR BACK WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.31199 2/18/21 13:14 1010 NTOVR BARN BACK WALL WOOD C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.41200 2/18/21 13:15 1010 NTOVR BARN LIVING ROOM DOOR WOOD B INTACT WHITE <LOD mg / cm ^2 Negative 1 1.42201 2/18/21 13:15 1010 NTOVR BARN LIVING ROOM CABINET WOOD C INTACT WHITE <LOD mg / cm ^2 Negative 1 0.84202 2/18/21 13:16 1010 NTOVR BARN LIVING ROOM CLOSETWALL WOOD D INTACT YELLOW<LOD mg / cm ^2 Negative 1 1.29203 2/18/21 13:16 1010 NTOVR BARN LIVING ROOM CLOSETWALL WOOD A INTACT PINK <LOD mg / cm ^2 Negative 1 1.2204 2/18/21 13:17 1010 NTOVR BARN STAIR WALL STAIR WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.3205 2/18/21 13:18 1010 NTOVR BARN STAIR RAIL WOOD A INTACT BLACK <LOD mg / cm ^2 Negative 1 1.67206 2/18/21 13:18 1010 NTOVR BARN RR2 SINK PLASTER A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.33207 2/18/21 13:19 1010 NTOVR BARN RR2 SHWR PLASTY A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.2208 2/18/21 13:19 1010 NTOVR BARN RR2 TOIL PLASTER C INTACT WHITE <LOD mg / cm ^2 Negative 1 0.85209 2/18/21 13:19 1010 NTOVR BARN RR2 DOOR WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.21210 2/18/21 13:20 1010 NTOVR BARN ART WINDOW WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 0.84211 2/18/21 13:20 1010 NTOVR BARN ART WALL WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.33212 2/18/21 13:20 1010 NTOVR BARN ART WALL WOOD C INTACT WHITE <LOD mg / cm ^2 Negative 1 1.19213 2/18/21 13:22 1010 NTOVR BARN TACK HAY DOOR WOOD A INTACT WHITE 0.02 mg / cm ^2 Negative 1 1.21

Assay No Time Site Structure Room Component Substrate Side Condition Color Pb Units Results Action LevelDuration

�5

Page 91: ASBESTOS AND LEAD BUILDING SURVEY

214 2/18/21 13:23 1010 NTOVR BARN TACK HAY DOOR F WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 1.29215 2/18/21 13:23 1010 NTOVR BARN TACK HAY COLUMN WOOD D INTACT WHITE 2.06 mg / cm ^2 Positive 1 0.98216 2/18/21 13:25 1010 NTOVR BARN EXT FENCE WOOD D INTACT WHITE 0.02 mg / cm ^2 Negative 1 3.62217 2/18/21 13:25 1010 NTOVR BARN EXT EAVE WOOD D INTACT WHITE 0.05 mg / cm ^2 Negative 1 2.45218 2/18/21 13:26 1010 NTOVR BARN EXT CARGO CONTAINR METAL A INTACT SILV 0.62 mg / cm ^2 Negative 1 1.4219 2/18/21 13:27 1010 NTOVR BARN EXT CARGO CONTAINR METAL B INTACT SILV <LOD mg / cm ^2 Negative 1 2.57220 2/18/21 13:27 1010 NTOVR BARN EXT CARGO CONTAINR METAL C INTACT SILV 0.05 mg / cm ^2 Negative 1 3.83221 2/18/21 13:28 1010 NTOVR BARN EXT CARGO&SHEDWALL WOOD A INTACT RED <LOD mg / cm ^2 Negative 1 1.41222 2/18/21 13:28 1010 NTOVR BARN EXT CARGO&SHEDWALL WOOD D INTACT RED <LOD mg / cm ^2 Negative 1 1.65223 2/18/21 13:28 1010 NTOVR BARN EXT CARGO&SHEDEAVE WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.32224 2/18/21 13:29 1010 NTOVR BARN EXT CARGO&SHEDEAVE METAL D INTACT SILV <LOD mg / cm ^2 Negative 1 1.32225 2/18/21 13:30 1010 NTOVR SHED INT CARGO&SHEDWALL WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.3226 2/18/21 13:30 1010 NTOVR SHED INT CARGO&SHEDWALL WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.31227 2/18/21 13:30 1010 NTOVR SHED INT CARGO&SHEDWINDOW WOOD D INTACT WHITE <LOD mg / cm ^2 Negative 1 1.28228 2/18/21 13:31 1010 NTOVR SHED INT CARGO&SHEDDOOR WOOD A INTACT WHITE <LOD mg / cm ^2 Negative 1 3.26229 2/18/21 13:33 1010 NTOVR CAL SRM SRM END CAL N/A N/A N/A RED 1.29 mg / cm ^2 Positive 1 2.61230 2/18/21 13:34 1010 NTOVR CAL SRM SRM END CAL N/A N/A N/A RED 1.08 mg / cm ^2 Inconclusive1 20.36231 2/18/21 13:35 1010 NTOVR CAL SRM SRM END CAL N/A N/A N/A RED 1.07 mg / cm ^2 Inconclusive1 21.13

END

Assay No Time Site Structure Room Component Substrate Side Condition Color Pb Units Results Action LevelDuration

�6

Page 92: ASBESTOS AND LEAD BUILDING SURVEY

APPENDIX D

CDPH 8552 LEAD HAZARD EVALUATION REPORT FORM

Page 93: ASBESTOS AND LEAD BUILDING SURVEY

LEAD HAZARD EVALUATION REPORT

California Department of Public HealthState of California—Health and Human Services Agency

Section 1 — Date of Lead Hazard Evaluation _____________________

Section 3 — Structure Where Lead Hazard Evaluation Was Conducted

Lead Inspection Risk assessment Clearance Inspection Other (specify) _____________________________

City County Zip Code

Construction date (year) of structure

Type of structure

Multi-unit building School or daycare

Single family dwelling

Section 4 — Owner of Structure (if business/agency, list contact person)

Address [number, street, apartment (if applicable)] City State

Name Telephone number

Section 5 — Results of Lead Hazard Evaluation (check all that apply)

No lead-based paint detected

No lead hazards detected

Intact lead-based paint detected

Lead-contaminated dust found

Section 6 — Individual Conducting Lead Hazard EvaluationName

Name and CDPH certification number of any other individuals conducting sampling or testing (if applicable)

CDPH certification number Signature Date

Section 7 — Attachments

A. A foundation diagram or sketch of the structure indicating the specifc locations of each lead hazard or presence of lead-based paint;B. Each testing method, device, and sampling procedure used;C. All data collected, including quality control data, laboratory results, including laboratory name, address, and phone number.

First copy and attachments retained by inspector

Second copy and attachments retained by owner

Third copy only (no attachments) mailed or faxed to:

California Department of Public HealthChildhood Lead Poisoning Prevention Branch Reports850 Marina Bay Parkway, Building P, Third FloorRichmond, CA 94804-6403Fax: (510) 620-5656

CDPH 8552 (6/07)

Zip Code

Address [number, street, apartment (if applicable)] City State Zip Code

Telephone number

Section 2 — Type of Lead Hazard Evaluation (Check one box only)

Address [number, street, apartment (if applicable)]

Other____________

No

Deteriorated lead-based paint detected

Lead-contaminated soil found Other____________________

Yes

Don’t Know

Children living in structure?

3.21.21

1010 North Twin Oaks Valley Road San Marcos San Diego 92069

1881✔ ✔

Mr. Groth 858 7354645

1010 North Twin Oaks Valley Road San Marcos CA 92069

Gavin Seedorf 8586883522

1053 Tourmaline St San Diego CA 92109

22987 3.21.21

lhundrup
BARN
Page 94: ASBESTOS AND LEAD BUILDING SURVEY

LEAD HAZARD EVALUATION REPORT

California Department of Public HealthState of California—Health and Human Services Agency

Section 1 — Date of Lead Hazard Evaluation _____________________

Section 3 — Structure Where Lead Hazard Evaluation Was Conducted

Lead Inspection Risk assessment Clearance Inspection Other (specify) _____________________________

City County Zip Code

Construction date (year) of structure

Type of structure

Multi-unit building School or daycare

Single family dwelling

Section 4 — Owner of Structure (if business/agency, list contact person)

Address [number, street, apartment (if applicable)] City State

Name Telephone number

Section 5 — Results of Lead Hazard Evaluation (check all that apply)

No lead-based paint detected

No lead hazards detected

Intact lead-based paint detected

Lead-contaminated dust found

Section 6 — Individual Conducting Lead Hazard EvaluationName

Name and CDPH certification number of any other individuals conducting sampling or testing (if applicable)

CDPH certification number Signature Date

Section 7 — Attachments

A. A foundation diagram or sketch of the structure indicating the specifc locations of each lead hazard or presence of lead-based paint;B. Each testing method, device, and sampling procedure used;C. All data collected, including quality control data, laboratory results, including laboratory name, address, and phone number.

First copy and attachments retained by inspector

Second copy and attachments retained by owner

Third copy only (no attachments) mailed or faxed to:

California Department of Public HealthChildhood Lead Poisoning Prevention Branch Reports850 Marina Bay Parkway, Building P, Third FloorRichmond, CA 94804-6403Fax: (510) 620-5656

CDPH 8552 (6/07)

Zip Code

Address [number, street, apartment (if applicable)] City State Zip Code

Telephone number

Section 2 — Type of Lead Hazard Evaluation (Check one box only)

Address [number, street, apartment (if applicable)]

Other____________

No

Deteriorated lead-based paint detected

Lead-contaminated soil found Other____________________

Yes

Don’t Know

Children living in structure?

3.21.21

1022 North Twin Oaks Valley Road San Marcos San Diego 92069

1971✔

Mr. Groth 858 7354645

1010 North Twin Oaks Valley Road San Marcos CA 92069

✔ LCS shower tile intact

Gavin Seedorf 8586883522

1053 Tourmaline St San Diego CA 92109

22987 3.21.21

lhundrup
Page 95: ASBESTOS AND LEAD BUILDING SURVEY

LEAD HAZARD EVALUATION REPORT

California Department of Public HealthState of California—Health and Human Services Agency

Section 1 — Date of Lead Hazard Evaluation _____________________

Section 3 — Structure Where Lead Hazard Evaluation Was Conducted

Lead Inspection Risk assessment Clearance Inspection Other (specify) _____________________________

City County Zip Code

Construction date (year) of structure

Type of structure

Multi-unit building School or daycare

Single family dwelling

Section 4 — Owner of Structure (if business/agency, list contact person)

Address [number, street, apartment (if applicable)] City State

Name Telephone number

Section 5 — Results of Lead Hazard Evaluation (check all that apply)

No lead-based paint detected

No lead hazards detected

Intact lead-based paint detected

Lead-contaminated dust found

Section 6 — Individual Conducting Lead Hazard EvaluationName

Name and CDPH certification number of any other individuals conducting sampling or testing (if applicable)

CDPH certification number Signature Date

Section 7 — Attachments

A. A foundation diagram or sketch of the structure indicating the specifc locations of each lead hazard or presence of lead-based paint;B. Each testing method, device, and sampling procedure used;C. All data collected, including quality control data, laboratory results, including laboratory name, address, and phone number.

First copy and attachments retained by inspector

Second copy and attachments retained by owner

Third copy only (no attachments) mailed or faxed to:

California Department of Public HealthChildhood Lead Poisoning Prevention Branch Reports850 Marina Bay Parkway, Building P, Third FloorRichmond, CA 94804-6403Fax: (510) 620-5656

CDPH 8552 (6/07)

Zip Code

Address [number, street, apartment (if applicable)] City State Zip Code

Telephone number

Section 2 — Type of Lead Hazard Evaluation (Check one box only)

Address [number, street, apartment (if applicable)]

Other____________

No

Deteriorated lead-based paint detected

Lead-contaminated soil found Other____________________

Yes

Don’t Know

Children living in structure?