PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM FEATURES: SPECS: FIXTURE/TYPE(S): PROJECT: FINISH OPTIONS INDIRECT OUTPUT LEVELS: 035 – 350LM/FT, 2.0W/FT 055 – 550LM/FT, 2.9W/FT 080 – 800LM/FT, 4.6W/FT 100 – 1000LM/FT, 6.0W/FT 120 – 1200LM/FT, 7.5W/FT 145 – 1450LM/FT, 9.4W/FT 170 – 1700LM/FT, 11.3W.FT* 220 – 2200LM/FT, 16.3W/FT* DIRECT OUTPUT LEVELS: 035 – 350LM/FT, 2.0W/FT 055 – 550LM/FT, 2.9W/FT 080 – 800LM/FT, 4.6W/FT 100 – 1000LM/FT, 6.0W/FT 120 – 1200LM/FT, 7.5W/FT 145 – 1450LM/FT, 9.4W/FT 170 – 1700LM/FT, 11.3W.FT* 220 – 2200LM/FT, 16.3W/FT* LUMENS IND/DIR COLOR TEMP 27K - 2700K WARM WHITE LED 30K - 3000K WARM WHITE LED 35K - 3500K NATURAL WHITE LED 40K - 4000K COOL WHITE LED 50K - 5000K ULTRA COOL WHITE LED 30KS - 3000K BIOS® STATIC 35KS - 3500K BIOS® STATIC 40KS - 4000K BIOS® STATIC 30KD - 3000-2700K BIOS® DYNAMIC 35KD - 3500-3000K BIOS® DYNAMIC 40KD - 4000-3500K BIOS® DYNAMIC VOLTAGE P - PENDANT / CANOPY (24" STANDARD) SP - SWIVEL PENDANT / CANOPY (45° / 24" STANDARD) AC - ADJUSTABLE AIRCRAFT CABLE (48" STANDARD) S - SURFACE T - STANDARD T-BAR CEILING FL - FLANGED FOR PLASTER OR DRY-WALL CEILINGS TRM - FLANGED FOR TRIMLESS MUD-IN APPLICATIONS Construction: Welded Extruded Aluminum housing. Internal components punched and die formed from cold rolled steel. Finish: Polyester powder coated white. Internal components are finished in high gloss white (Min. Reflectance Factor = 90%). Consult Factory for custom finishes. Dimming: Fixtures supplied with 0-10V dimming down to 1% as standard. Other Dimming option are available (Consult Factory). Listing: Fixtures are cETLus listed for Damp Location. OUTPUT TYPE FINISH VOLTAGE MOUNTING OPTIONS OUTPUT TYPE D - DIRECT I - INDIRECT DI - DIRECT/INDIRECT LUMENS IND/DIR WHT - WHITE POWDER COAT BLK - BLACK POWDER COAT SLV - SILVER POWDER COAT CA - CUSTOM COLORS (CONSULT FACTORY) UNV - UNIVERSAL (120/277V) MOUNTING GLR - IN LINE FUSING EM - EMERGENCY DRIVER (CONSULT FACTORY) 90C - 90CRI LED BOARDS †LAYOUTS OF DIFFERENT CONFIGURATIONS REQUIRE PMC ENGINEERING DRAWINGS TO DETERMINE EXACT CONFIGURATIONS PRIOR TO QUOTATION. †SEE PAGE 2 FOR LUMEN DERATING CHART BY COLOR TEMP AND CRI Specifications and Dimensions are subject to change without notice. ArcX-N Series High Efficiency LED Direct/Indirect, Direct or Indirect • Recessed, Surface or Suspended COLOR TEMP+ DIFFUSER DIFFUSER FWOA - FROSTED WHITE ACRYLIC LENS - LAY-IN FPC - FROSTED POLYCARBONATE LENS - LAY-IN SIZE CODE† SERIES ARCX-N UNV / ArcX-N-004 Marrying shape and style with versatility and efficiency. ArcX-N modules allow construction of a wide variety of system contours and shapes in a narrower width than our ArcX models. ARCX-N is available in a wide variety of diameters in full rings (360°), radius (180°, 90°, 45°) and angle sectional curves, and linear lengths (up to 8') to help you design the perfect shape layout. + SEE FOLLOWING PAGES FOR MORE INFORMATION ABOUT THIS OPTION *NOT AVAILABLE IN BIOS

ArcX-N · When the fixture size allows, the "sweep" designation is called out as a letter indicating a full diameter (D), a 180˚ sweep (H), a 90˚ sweep (Q), a 45˚ sweep (E). All

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ArcX-N · When the fixture size allows, the "sweep" designation is called out as a letter indicating a full diameter (D), a 180˚ sweep (H), a 90˚ sweep (Q), a 45˚ sweep (E). All

PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COMPMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM

6' FIXTURE W/(3) 22" LED BOARD:

FEATURES:

SPECS:

FIXTURE/TYPE(S): PROJECT:

FINISH

OPTIONS

INDIRECT OUTPUT LEVELS:035 – 350LM/FT,  2.0W/FT055 – 550LM/FT,  2.9W/FT080 – 800LM/FT, 4.6W/FT100 – 1000LM/FT,  6.0W/FT120 – 1200LM/FT, 7.5W/FT145 – 1450LM/FT, 9.4W/FT170 – 1700LM/FT, 11.3W.FT*220 – 2200LM/FT, 16.3W/FT*

DIRECT OUTPUT LEVELS:035 – 350LM/FT,  2.0W/FT055 – 550LM/FT,  2.9W/FT080 – 800LM/FT, 4.6W/FT100 – 1000LM/FT,  6.0W/FT120 – 1200LM/FT, 7.5W/FT145 – 1450LM/FT, 9.4W/FT170 – 1700LM/FT, 11.3W.FT*220 – 2200LM/FT, 16.3W/FT*

LUMENS IND/DIRCOLOR TEMP

27K - 2700K WARM WHITE LED30K - 3000K WARM WHITE LED35K - 3500K NATURAL WHITE LED40K - 4000K COOL WHITE LED50K - 5000K ULTRA COOL WHITE LED30KS - 3000K BIOS® STATIC35KS - 3500K BIOS® STATIC40KS - 4000K BIOS® STATIC30KD - 3000-2700K BIOS® DYNAMIC35KD - 3500-3000K BIOS® DYNAMIC40KD - 4000-3500K BIOS® DYNAMIC

VOLTAGE

P - PENDANT / CANOPY (24" STANDARD)SP - SWIVEL PENDANT / CANOPY (45° / 24" STANDARD)AC - ADJUSTABLE AIRCRAFT CABLE (48" STANDARD)S - SURFACET - STANDARD T-BAR CEILINGFL - FLANGED FOR PLASTER OR DRY-WALL CEILINGSTRM - FLANGED FOR TRIMLESS MUD-IN APPLICATIONS

Construction: Welded Extruded Aluminum housing. Internal components punched anddie formed from cold rolled steel.Finish: Polyester powder coated white. Internal components are finished in high glosswhite (Min. Reflectance Factor = 90%). Consult Factory for custom finishes.Dimming: Fixtures supplied with 0-10V dimming down to 1% as standard. OtherDimming option are available (Consult Factory).Listing: Fixtures are cETLus listed for Damp Location.

OUTPUT TYPE FINISH VOLTAGEMOUNTING OPTIONS

OUTPUT TYPE

D - DIRECTI - INDIRECTDI - DIRECT/INDIRECT

LUMENS IND/DIR

WHT - WHITE POWDER COATBLK - BLACK POWDER COATSLV - SILVER POWDER COATCA - CUSTOM COLORS (CONSULT FACTORY)

UNV - UNIVERSAL (120/277V)

MOUNTING

GLR - IN LINE FUSINGEM - EMERGENCY DRIVER (CONSULT FACTORY)90C - 90CRI LED BOARDS

†LAYOUTS OF DIFFERENT CONFIGURATIONS REQUIRE PMC ENGINEERING DRAWINGS TO DETERMINE EXACTCONFIGURATIONS PRIOR TO QUOTATION.

†SEE PAGE 2 FOR LUMEN DERATING CHART BY COLOR TEMP AND CRI 

Specifications and Dimensions are subject to change without notice. 

ArcX-N SeriesHigh Efficiency LED

Direct/Indirect, Direct or Indirect • Recessed, Surface or Suspended

COLOR TEMP+

DIFFUSER

DIFFUSER

FWOA - FROSTED WHITE ACRYLIC LENS - LAY-INFPC - FROSTED POLYCARBONATE LENS - LAY-IN

SIZE CODE†SERIES

ARCX-N UNV/

ArcX-N-004

Marrying shape and style with versatility and efficiency. ArcX-N modules allowconstruction of a wide variety of system contours and shapes in a narrower width thanour ArcX models.

ARCX-N is available in a wide variety of diameters in full rings (360°), radius(180°, 90°, 45°) and angle sectional curves, and linear lengths (up to 8') tohelp you design the perfect shape layout.

+ SEE FOLLOWING PAGES FOR MORE INFORMATION ABOUT THIS OPTION

*NOT AVAILABLE IN BIOS

Page 2: ArcX-N · When the fixture size allows, the "sweep" designation is called out as a letter indicating a full diameter (D), a 180˚ sweep (H), a 90˚ sweep (Q), a 45˚ sweep (E). All

PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM

DIRECT/INDIRECT DIRECT OR INDIRECT

BIOS Illuminated®BIOS SkyBlue® lighting solutions contribute to satisfying Circadian LightingDesign Feature 54 under WELL Building Standard v1 and Feature L03 under theWELL Building Standard v2.  BIOS SkyBlue also meets other features within theWELL Light Concept, including color quality with 83+ CRI and R9 values at 90,visual comfort metrics, and higher m/p ratios than traditional LED lighting.

STATIC LIGHT ENGINE – Option Codes 30KS, 35KS, 40KSBIOS SkyBlue Static Spectrum lighting solutions support proper daytime circadianstimulus, communicating directly with human circadian biology through a non-visual photo receptor in the eye.  With SkyBlue, there is no need for color tuning,color temperature adjustments or significantly increasing light levels.  Consider theStatic Spectrum Light Engine when the fixtures will illuminate spaces occupiedprimarily during the daytime hours.

DYNAMIC LIGHT ENGINE – Option Codes 30KD, 35KD, 40KDBIOS SkyBlue Dynamic Spectrum lighting solutions provide full daytime circadianstimulus, communicating directly with human circadian biology through a non-visual photo receptor in the eye.  With SkyBlue, there is no need for color tuning,color temperature adjustments, or extra illumination.  The SkyBlue Dynamic LightEngine automatically calibrates the light level, reducing melanopic lux whilekeeping photopic lux at a constant level when used in conjunction with properdimming controls.  Consider the Dynamic Spectrum Light Engine when the fixtureswill illuminate spaces occupied during both daytime and nighttime hours.

ArcX-N size codes are based on nominal radius or nominal diameter followed by aletter or number indicating the extent of the sweep of the radius. When the fixturesize allows, the "sweep" designation is called out as a letter indicating a full diameter(D), a 180˚ sweep (H), a 90˚ sweep (Q), a 45˚ sweep (E). All other sweepdesignations are called out in degrees followed by the letter "A" indicating an anglesuch as 15˚ (15A). Custom sized fixture may require custom nomenclature.

Not all radius fixtures can be constructed to specific angles without the introductionof unlit area in the fixture as dictated by the layout of LED boards. PMC uses LEDboards of varying sizes (5.5", 11" and 22" lengths) depending on fixture radius andlayout required for proper driver loading. This insures even illumination throughoutan assembled pattern regardless of fixture sizes required to build the specifiedpattern. Generally any unlit area would be limited to 5.5" or less. Unless otherwiserequested, as standard practice, fixture angles or sweep would be lowered whereverpossible to eliminate any unlit area on the direct side lens.

ArcX-N Series

SIZE CODE NOMENCLATURE NOTES

ArcX-N-004

LUMEN DERATING CHART BYCOLOR TEMP AND CRI

The narrow profile of the ARCX-N models present some challenges when incorporating larger fixture components into acurved fixture.  The tightness of the radius play’s a large part in what can and cannot be done to fit larger componentintegral to the fixture.  Outside fixture radii down to 1’ 5-1/4” are possible but may require remote mounting of drivers, maylimit the availability of tunable solution such as our Aura Technology, may limit the use of our pur-led disinfectingtechnology, may require different size LED boards changing the radii available for a given angle of sweep (or angle of sweepfor a given radius).  Please consult the PMC factory with your requirements so that solutions for you ARCX-N needs may beworked out.

Page 3: ArcX-N · When the fixture size allows, the "sweep" designation is called out as a letter indicating a full diameter (D), a 180˚ sweep (H), a 90˚ sweep (Q), a 45˚ sweep (E). All

PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM

ArcX-N Series

PHOTOMETRIC DATA FOR ARCX-N: BEING A CURVED FIXTURE OF MANY POSSIBLE RADII AND ANGLES OF SWEEP,ARCX-N PHOTOMETRIC DATA AND .IES FILES ARE SUPPLIED IN SHORT 1 FOOT LONG STRAIGHT SEGMENTS THATCAN BE LAID OUT IN YOUR ANALYSIS SOFTWARE TO APPROXIMATE THE CURVE AND SIZE OF THE ARCX-NFIXTURE IN YOUR PARTICULAR DESIGN. THE DATA SHOWN BELOW IS BASED ON THESE 1 FOOT LONG SEGMENTSAND DO NOT DEPICT ANY ACTUAL ARCX-N FIXTURE CONFIGURATION AS FAR AS TOTAL LUMEN OUTPUT, TOTALWATTAGE, LUMINOUS SIZE, SPACING CRITERIA, ETC. ARE CONCERNED. LUMINAIRE EFFICIENCY, LUMENS PERFOOT, WATTAGE PER FOOT AND LIGHT OUTPUT DISTRIBUTIONS ARE ACCURATE FOR THE 1 FOOT LENGTH ANDARE RELIABLE APPROXIMATIONS OF HOW A 1 FOOT LONG CURVED SECTION OF ARCX-N WILL PERFORM.

CONSULT PMC LIGHTING FOR PHOTOMETRIC CONFIGURATIONS NOT SHOWN

ArcX-N-004